To whom it may concern:
Please find enclosed stormwater sampling results for Stormwater Discharge Outfalls #001 and
#002 for the Cleveland facility in the month of December 2019. The storm water samples were
collected on December 17, 2019. Results from this sampling event show an exceedance of the
following parameters at or above the corresponding benchmarks:
• SDO #002 -Zinc - 0.180 mg/L (Benchmark 0.126 mg/L)
Included with the November 2018 Discharge Monitoring Report Cleveland facility provide re -
notification under the NPDES General Permit No. NCG030000, effective November 1, 2018 that
the facility remains in Tier Three for SDO 001 and SDO 002. Daimler Trucks Cleveland facility is
awaiting notification from the Division of Water Quality as to what changes will occur when
entering into Tier Three of the NPDES General Permit.
Should you have any questions, please contact me at 704-645-5353 or
lindsev.soeed@daimler.com.
Sincerely,
Daimler Trucks, LLC
Lindsey Speed Nichols
Sr. Environmental Engineer
Enclosures
RECEIVED
JAN 16 2020
CENTRAL FILES
D" SECTION
*$xIELDERING. INC.
January 7, 2020
Ms. Lindsey Speed Nichols
Daimler Trucks of North America, LLC
11550 Statesville Boulevard
Cleveland, NC 27013
Subject: Monthly Sampling — December 2019
NPDES General Permit No. NCG030000/CoC No. NCG030039
Daimler Trucks of North America, LLC
11550 Statesville Boulevard, Cleveland, North Carolina
Shield Project No. 1140111-06
Dear Ms. Nichols:
RECEIVED
JAN 16 2020
CcNTi;&iL FILES
DWR SECTION
Shield Engineering, Inc. (Shield) successfully collected a monthly stormwater sample for Stormwater Discharge
Outfall (SDO) #001 and SDO 4002 at the Cleveland facility in the month of December 2019. During the
December 171h sampling event, Shield's field measurements of pH were 6.98 and 7.22, respectively, at SDO
#001 and SDO 4002. The analytical results of the stormwater sample collected during the qualifying storm event
on December 17', 2019 are attached to this cover letter. In addition, the Qualitative Monitoring Report (QMR)
forms and the partially completed Discharge Monitoring Report (DMR) form are attached to this cover letter.
The QMRs should be kept onsite. Results from the sampling event show an exceedance at SDO #002 for zinc.
Daimler's Cleveland facility remains in Tier Three of the NPDES General Permit No. NCG030000 at SDO 4001
for Copper. The facility remains in Tier'1'hree at SDO #002 for Copper and Zinc. The person designated to act
as the permittee by Daimler Trucks — Cleveland Facility should complete all "Red" sections of the attached
Stormwater Discharge Monitoring Report (DMR). The completed DMR form should then be mailed to the
regulatory agency Central Files. Shield greatly appreciates the opportunity to provide environmental services to
Daimler Trucks of North America. If you have any questions in reference to this document or require further
information, please feel free to contact either of the undersigned at (704) 394-6913.
Respectfully,
SHIELD ENGINEERING, INC.
Mel' da re IT
Sen� r E gineer
ATTACHMENTS
4Robe4GriffinP
President/CEO
4301 Taggart Creek Road Telephone 704.394.6913
Charlotte, NC 28208 w .shieldengineenng.com Fax 704.394.6966
- Stormwater-Discharge Monitoring Report
for North Carolina Division of Energy, Mineral and Land Resources General Permit No. NCG030000
Date submitted
CERTIFICATE OF COVERAGE NO. NCG03 O 0 3 9
FACILITY NAME Daimler Trucks North America LLC -Cleveland, NC
COUNTY Cleveland
PERSON COLLECTING SAMPLES Kevin 3tachura (Shield Engineering, Inc.
LABORATORY Shealy Env Services, Inc Lab Cert. # 329
1/712020
SAMPLE COLLECTION YEAR 2019
SAMPLE PERIOD ❑ Jan -June ❑ July -Dec
or Q Monthly' December /month)
DISCHARGING TO CLASS ❑ORW ❑HQW ❑Trout ❑PNA
❑Zero -flaw [:]Watersupply ❑SA
Comments on sample collection or analysis: ❑■ Other
Zinc exceeded at SOO #002. RECEIVED
Part A: Stormwater Benchmarks and Monitoring Results
JAN 16 2020
:EN _RAL FILES
DWR SECTION
PLEASE REMEMBER TO SIGN ON PAGES 2 AND/OR 3 -->
No discharge this period?2
Outfall No.
Date Sample
Collected'
(mo/dd/yr)
24-hour rainfall
amount,
Inches'
Total Suspended Solids
pH
Standard units
Total Copper
Total Lead
Total Zinc
Nan -Polar O&G/
Total Petroleum
Hydrocarbons
Total Toxic
Organics
Benchmarks
_
-
100 mg/L or SO mg/L4
6.0 — 9.0
0.010 mg/L
0.07S mg/L
0.126 mg/L
1S mg/L
1 mg/L
Parameter Code
-
46529
C0530
00400
01119
01051
01094
00552
78141
SDO #001
12/1719
0.28
18
6.98
0.0083
0.0011
0.063
<5.0
<0.2036
SDO#002
12/17/19
0,28
16
7.22
0.0073
0.0012
0A80
<5.0
40.2114
' Monthly sampling (instead of semi-annual) must begin with the second consecutive benchmark exceedance for the same parameter at the same outfall.
' For sampling periods with no discharge at any single outfall, you must still submit this discharge monitoring report with a checkmark here.
'The total precipitation must be recorded using data from an on -site rain gauge. Unattended sites may be eligible for a waiver of the rain gauge requirement.
4 See General Permit, Section B, Table 1 to identify the especially sensitive receiving water classifications where the more protective benchmark applies.
' Total Toxic Organics sampling is applicable only for those facilities which perform metal finishing operations, manufacture semiconductors, manufacture
electronic crystals, or manufacture cathode ray tubes. For purposes of this permit the definition of Total Toxic Organics is that definition contained in the EPA
Effluent Guidelines for the facility subject to the requirement to sample (for metal finishing use the definition as found in 40 CFR 433.11; for semiconductor
manufacture use the definition as found in 40 CFR 469.12; for electronic crystal manufacture use the definition as found in 40 CFR 469.22; and for cathode ray
tube manufacture use the definition found in 40 CFR 469.31).
Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 111112018
Pagel of 3
Facilities that incorporate a solvent management plan intotheStormwater Pollution Prevention Plan may so certify,- and the requirement for TTO monitoring
may be waived. The solvent management plan shall include a list of the total toxic organic compounds used and the other elements listed in the General
Permit. For those facilities electing to employ the TTO monitoring waiver, the discharger shall sign the following certification statement:
"Based upon my inquiry of the person or persons directly responsible for managing compliance with the permit monitoring requirement for total toxic organics
(TTO), I certify that to the best of my knowledge and belief, no dumping of concentrated toxic organics into the stormwater or areas which are exposed to rainfall or
stormwater runoff has occurred since filing the last discharge monitoring report. I further certify that this facility is implementing the all the provisions of the
solvent management plan included in the Stormwater Pollution Prevention Plan."
Eny- Johnson
Name (Print name)
? tn} NMAnztW
Title (Print title)
/ z�
Signatur
Date
Note: Results must be reported in numerical format. Do not report Below Detection Limit, BDL, <PQL, Non -detect, ND, or other similar non -numerical
format. When results are below the applicable limits, they must be reported in the format, "<XX mg/L", where XX is the numerical value of the detection
limit, reporting limit, etc. in mg/L.
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
Part B: Vehicle Maintenance Area Monitoring Results: only for facilities averaging > 55 gal of new oil per month.
F� No discharge this period?z
Outfall No.
Date Sample Collected'
(mo/dd/yr)
24-hour rainfall amount,
Inches3
New Motor Oil or
Hydraulic Oil Usage
Non -Polar O&G/ Total
Petroleum Hydrocarbons
Total Suspended
Solids
Benchmarks
-
-
-
1S mg/L
100 mg/L or 50 mg/L°
Parameter Code
-
46529
NCOIL
00552
C0530
Footnotes from Part A also apply to Part B
Note: If you report a sample value in excess of the benchmark, you must implement Tier 1, Tier 2, or Tier 3 responses. See General Permit text.
Permit Date: 11/1/2018-05/31/2021 SWU-245, last revised 11/1/2018
Page 2 of 3
FOR. PART A AND PART B MONITORING RESULTS:
• A BENCHMARK EXCEEDANCE TRIGGERS TIER 1 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• 2 EXCEEDANCES IN A ROW FOR THE SAME PARAMETER AT THE SAME OUTFALL TRIGGER TIER 2 REQUIREMENTS. SEE PERMIT PART II SECTION B.
• TIER 3: HAS YOUR FACILITY HAD 4 OR MORE BENCHMARK EXCEEDENC S FOR THE SAME PARAMETER AT ANY ONE OUTFALL? YES ✓f NO ❑
IF YES, HAVE YOU CONTACTED THE DEMLR REGIONAL OFFICE? YES NO ❑
REGIONAL OFFICE CONTACT NAME: �aAw-wtrc1 egVy)
Mail an original copy of this DMR including all "No Discharge" reports within 30 days of receipt of the lab results (or at end of monitoring period in the
case of "No Discharge" reports) to:
Division of Water Quality
Attn: DWQ Central Files
1617 Mail Service Center
Raleigh, North Carolina 27699-1617
YOU MUST SIGN THIS CERTIFICATION FOR ANY INFORMATION REPORTED:
"I certify, under penalty of law, that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to
assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or
those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. I
am aware that there are significant penalties for submitting false information, including the possibility of fines and imprisonment for knowing violations."
11f S/Lv
Date
Permit Date: 11/1/2018-05/31/2021 SWU-2451 last revised 11/1/2018
Page 3 of 3