Loading...
HomeMy WebLinkAboutWQ0009593_More Information (Requested)_19940620State bf North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director Mr. Peter Vandenberg City of Laurinburg P.O. Box 249 Laurinburg, NC 28353 Dear Mr. Vandenberg: A14 • • G7EHmod& NF1 June 20, 1994 r N UUN 22 1994 ENV. MAN •I,,kGEMENT fAYETTEVILLE PEG. OFFICE Subject: Application No. WQ0009593 Additional Information Request City of Laurinburg Braemar Subdivision Section I Scotland County The Permits and Engineering Unit has completed a preliminary engineering review of the subject application. The following items must be addressed before we can complete our review: In accordance with 15A NCAC 211 .0219 (i) (2) (G) (ii), a water line must cross at least 18 inches above a sanitary sewer line. If this minimum distance is not possible, the sewer line must be constructed of DIP. Please correct the following locations on you profiles to comply with the regulated separations: Sheet 2 of 2, Between MH#3 and MH#4 the existing 8 inch water line is not 18 inches, Sheet 2 of 2 between MH#5 and MH#10 shows a water line not separated by 18 inches. 2. In accordance with 15A NCAC 2H .0219 (i) (2) (G) (i), a minimum vertical separation of 12 inches must be maintained where storm sewers cross the sanitary sewer (including force mains). Please revise the following sheet(s) of your plans to conform to this requirement: Sheet 2 of 2 between MH#5 and MH#10, needs 1 foot cover. 3. The Division cannot approve plans affixed with a stamp of "Preliminary"`- or "Not For Construction." Please forward two copies of your plans, without such a stamp, to my attention. A note which reads "FINAL DESIGN -Not Released For Construction" will be acceptable if so desired by the applicant. 4.In accordance with 15A NCAC 2H .0219 (1) (1), the Division requires that a value of 120 GPD per bedroom, with a minimum value of 240 GPD per unit, be used to calculate the estimated volume of wastewater generated for residential dwelling units (DU). Please indicate the specific number of bedrooms per DU, and recalculate the total flow volume estimate using this figure. If the recalculated value is different from that originally calculated, please revise page 2 of your application and forward 3 signed and sealed copies of that page to my attention. Note: If the total volume estimate doesn't change, please call me with the information regarding the specific number of bedrooms, or just include the info in a letter to my attention. (There is no need to revise the application in that case.) P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper Refer to the subject permit application number when providing the requested information. Please submit two (2) copies of all information to my attention at the address below. Also, please note that failure to provide this additional information on or before July 19, 1994 will subject your application to being returned as incomplete, in accordance with 15A NCAC 2H .0208. If you have any questions on this matter, please call me at (919) 733-5083 ext. 544. cc: Fayetteville Regional Office, Water Quality J. F. Wampler Engineering, Inc. Permit File WQ0009593 Sincerely, G a 11 �6—/- Randy L .Kepler Environmental Engineer State Engineering Review Group 9 r 7 DIVISION OF ENVIRONMENTAL MANAGEMENT REGIONAL OFFICES (11/93) Asheville Regional WQ Supervisor 59 Woodfin Place Asheville, NC 28801 (704) 251-6208 Fax (704) 251-6452 Avery Buncombe Budge McDowell Caldwell Mitchell Cherokee Polk Clay Rutherford . Graham Swain Haywood Transylvania Henderson Yancy Jackson Fayetteville Regional WQ Supervisor Wachovia Building, Suite 714 Fayetteville, NC 28301 (910)486-1541 Fax (910) 486-0707 Washington Regional WQ Supervisor Post Office Box 1507 Washington, NC 27889 (919) 946-6481 Fax (919) 975-3716 Raleigh Regional WQ Supervisor Post Office Box 27687 Raleigh, NC 27611 (919) 571-4700 Fax (919) 5714718 Beaufort Jones Chatham Nash Bertie Lenoir Durham Northampton Camden Martin Edgecombe Orange Chowan Pamlico Franklin Person Craven Pasquotank Granville Vance Currituck Perquimans Halifax Wake Dane Pitt Johnston Warren Gates Tyrell Lee Wilson Greene Washington Hertford Wayne Hyde Mooresville Regional WQ Supervisor 919 North Main Street Mooresville, NC 28115 (704) 663-1699 Fax (704) 663-6040 Wilmington Region. WQ Supervisor 127 Cardinal Drive Extension Wilmington, NC 28405-3845 (910) 395-3900. Fax (910) 350-2004 Anson Moore Alexander Mecklenburg Brunswick New Hanover Bladen Robeson Cabarrus Rowan Carteret Onslow Cumberland Richmond Catawba Stanly Columbus Fender Harnett Sampson Gaston Union Duplin Hoke Scotland Iredell Cleveland Montgomery Lincoln Winston-Salem Regional WQ Supervisor 8025 North Point Boulevard, Suite 100 Winston-Salem, NC 27106 (910) 896-7007 Fax (910) 896-7005 Alamance Rockingham Alleghany Randolph Ashe Stokes Caswell Sunry Davidson Watauga Davie Wilkes Forsyth Yadkin Guilford FORM: GSA 04/94 Page 6 of 6 Name and Complete Address of Engineering Firm: J . F . Wampler Engineering, Inc. _P_ n_ Box 1782 City: Laurinburg State: NC Zip: 28353 Telephone Number: ( 910 ) 2 7 6— 8 3 0 6 Professional Engineer's Certification: I, Joseph F. Wampler , attest that this application for the City of Laurinburg has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Seal, Signature, and Date: O�tH CAROZ/ QV 9� •: SEAL 0. 5364 0 • ✓ems '•.;1'G! N EE� •Q��� .; Applicant's Certification: I, Peter G . Vandenberg , attest that this application for Braemar Subdivision —Sect. 1 has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be retummd to me_ps incomplete. Signature THE COMPLETED APPLICATION PACK0 MATERIALS, SHOULD BE Date 6-13-94 NCLUDING ALL SUPPORTING INFORMATION AND 1T TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: (919) 733-5083 FORM: GSA 04/94 Page 5 of 6