Loading...
HomeMy WebLinkAboutWQ0016423_Application_19990209t2 ie State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary A. Preston Howard, Jr., P.E., Director Mr. Gray Walls, Town Engineer Town of Troy 444 North Main Street Troy, North Carolina 27371 Dear Mr. Walls: NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RECEIVED February 9, 1999 FEB 10 1999 FAYMEVILLE REG. OFFICE Subject: Application No. WQ0016423 Poole Road Subdivision Sewer -Public Montgomery County The Division's Permits and Engineering Unit acknowledges receipt of your permit application and supporting materials on February 8, 1999. This application has been assigned the number listed above. Your project has been assigned to Mr. Ron Palumbo for a detailed engineering review. Should there be any questions concerning your project, the reviewer will contact you with a request for additional information. Be aware that the Division's Regional Office, copied below, must provide recommendations from the Regional Supervisor or a Procedure Four Evaluation for this project, prior to final action by the division. If you have any questions, please contact Mr. Ron Palumbo at 91gn33-5083 ext. 533 .If the engineer is unavailable, you may leave a message on their voice mail and they will respond promptly. PLEASE REFER TO THE ABOVE APPLICATION NUMBER WHEN MAKING INQUIRES ON THIS PROJECT. Sincerely, j,'/1 -M(+)'. - I r. Kim H. Colson, E. Supervisor, Non -Discharge Permitting Unit cc: Fayetteville Regional Office, Water Quality Central Carolina Engineering, PA P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper ----"" ' State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management Non -Discharge Permit Application t ci; (THIS FORM MAY BE PHOTOCOPIED FOR USE AS AN ORI(5INAL) GRAVITY SEWER EXTENSION Fri 0 8 PUMP STATIONS, AND PRESSURE SEWERS-,��y riir,G I. GENERAL INFORMATION: 1. Applicant's name (please specify the name of the municipality, corporation, individual, etc.): Town of Troy 2. Print Owners or Signing Official's name and title (the person who is legally responsible for the facility and its compliance): Gray Walls, Town Engineer 3. Mailing address: 444 North Main Street City: Troy State: NC Zip: 27371 Telephone Number. ( 910 ) 5 7 2— 9 2 2 6 4. Project Name (please specify the name of the subdivision, facility, or establishment - should be consistent with project name on plans, specifications, letters of flow acceptance, Operational Agreements, etc.): Poole Road Subdivision Sewer System 5. Application Date: 1/ 7/ 9 9 6. Fee Submitted: S $ 4 0 0 6. County where project is located: Montgomery II. PERMIT INFORMATION: 1. Application No. (will be completed by DElvi): f(_(2(423 2. Specify whether project is: X new; modification. 3. If this application is being submitted as a result of a modification to an existing permit, please complete: existing permit number and the issue date 4. Specify whether the applicant is X public or private. III. INFORMATION ON WASTEWATER: 1. Nature of Wastewater. 1 0 0 % Domestic/Commercial ; % Industrial; % Other waste (specify): 2. Please provide a one or two word description specifying the origin of the wastewater, such as school, subdivision, hospital. commercial, industrial, apartments, etc.: Subdivision 3. Indicate any parameter(s) (and their concentration) that will be greater than normal domestic levels: None 4. If wastewater is not domestic in nature, what level of pretreatment has been provided to ensure protection of the receiving wastewater treatment facility? N / A FOR.": GSPSA 11/93 Page 1 of 5. If a pretreatment permit is required, has one been issued? Yes No. If yes, please attach a copy of the pretreatment permit. If No, when will one be issued 6. Volume of wastewater generated by this project: 2 5 0 0 - gallons per day. 7. Explanation of how wastewater volume was determined: Assume 350 GPD per household IV. DESIGN INFORMATION: 1. Briefprojectdescription: 1- Section.�of gravity sewer runs behind p rnpncacJ hnnaAs to small grinder pumpostation. A 2" forcemain will carry sewer approx 650 feet to existing sewer collection system. 2. Name of wastewater treatment facility receiving wastewater. Town of Troy a. Facility Permit Number. NC 0 0 2 8 916 b. Engineer should provide statement of his evaluation of downstream sewers ability to accept the wastewater. Down stream sewer collection line, pump station and fnrcemain will have no prnhlem with this flew. c. Permit Number for sewers immediately downstream: Unknown 611 d Pipe diameter of sewers immediately downstream: 3. Summary of sewer pipe to be permitted, by diameter size and pipe material: Diameter (in) Length (linear feet) Pipe Material Circle or N Factor & Specify Value Minimum Slope (%) Maximum Slope (%) Minimum Velocity (fps) Maximum Velocity (fps) Minimum Cover (in) 8 389 PVC --- 140 :67 .67 2.12 3.43 36 NOTE: The minimum velocity must not be less than 2 fps. For public sewers the minimum diameter is 8 Inches. For private sewers the minimum diameter Is 6 inches. 4. Anchors shall be provided for sewers with slopes greater than 20 %. The anchor spacing shall be a maximum of: 36 fat separation for slopes of 21% to 35%; 24 feet separation for slopes of 36% to 50%; 16 feet separation for slopes greater than 50%. For velocities greater than 15 fps, it is strongly recommended that measures be considered which will protect the sewers and manholes from erosion. For velocities greater than 20 fps, erosion pontrol measures must be specified. For any excessive slopes or velocities that will occur in any sewer line segment, what measures have been taken to protect the sewer pipe and manholes? N / A FORM: GSPSA 11/93 Page 2 of 8 5. Maximum sewer reach length between manholes: 389 linear feet. 6. This sewer line segment occurs between manhole no. 1 and niWW" pump station ialii 7. Does the owner/operator have the ability to clean this length? x Yes No. For sewer reach lengths greater than 425 feet, please provide a letter from the owner/operator, stating the ability to clean the speed reach and include the equipment specifications. 8. Sewers subject to existing or planned traffic bearing loads? Yes x No. If yes, what measures are being taken to enable the sewers to withstand the loads? 9. Outside drop manholes are provided where invert separations exceed:2 ' S feet (provide for separations > or = 2-T) 10. Identify (by manhole number) those manholes that have drop connections: None 11. Maximum allowable infiltration/exftltration test rate: 100 NOTE: Must not exceed 100 GPD/pipe diameter inchtmile of pipe. GPD/pipe diameter inch/mile of pipe. 12. Minimum separation distances as shown on the plans or addressed in the specifications. If a. b, or c below is no, explain in an attachment (This section must be completed for all collection systems including force mains and pressures sewers): a). 100 ft. horizontal separation from wells or other water supplies? x Yes No b) 12 in. vertical separation from storm sewer or ferrous pipe sanitary sewer speed? -.&- Yes No c) 10 ft. horiz. sep. from water mains or 18 in vertical sep. (water over sewer) or ferrous pipe specified? x Yes --No 13. Are manholes subject to flooding? Yes x No. If yes, are manhole rim elevations 1 foot above 100-year flood level, (100 year flood elevation should be indicated on plans) Yes No; Or, are manholes watertight and vented 1 foot above the 100-year flood elevation ( should be shown on plans): Yes No 14. Identify (by manhole number) those manholes that are vented 15. Does this project involve any stream crossings? X— Yes No. If yes, what precautions or special features have been utilized to ensure protection of the sewer line and not restrict stream flow? Identify the sheet of the plans and station number where stream crossings are located: Ductile iron pipe specified fog- crossing with V-6" cover below stream bed. Ref Sheet #2, station 5+20. Please note: The Division recommends all stream crossings be located three (3) feet below the stream bed or ferrous material pipe be specified. In addition, all aerial stream crossings must be located above the 25-year flood elevation. Both the 25-year flood elevation and the 100-year flood elevation should be indicated on the plans. 16. Sewers may = be installed in WS-I watersheds. Are any of the subject wastewater collection systems located in a WS-1 watershed? Yes x No. 17. Miscellaneous comments: FORM: GSPSA 11193 Page 3 of 8 V V. PUMP STATION INFORMATION 1. Pump Station No. or Name: Poole Road(A separate sheet 4 of 8 should be submitted for each pump station) 2. Name of closest downslope surface waters: Warner Creek 3. Classification of closest downslope surface waters: Class C (as established by the Environmental Management Commission & specified on sheet 5 of 8 of this application). 4. In accordance with 15A NCAC 2H .0219 (h)(3), describe the measures that are being implemented to prevent impacts on downslope surface waters, should a power failure occur at this pump station. NOTE: Alternative power MUST be addressed for every pump station in accordance with the above regulation. at station SCADA system to be installer 5. What size pumps are provided: 26 GPM; and how many? 2 6. What is the design total dynamic head? 41 fat How many pumping cycles will occur at average daily flow? 2.2 6 cycles per hour. NOTE: 15A NCAC 2H .0219 (h)(2) requires 2 to 9 pumping cycles per hour be achieved at average daily flow. 8. The following items are typically required in the design for pump stations. Check the appropriate blank to signify that these items havC h= provided in the design plans/specifications: Alternate Power Source Wet Well Vented with Screen Fillets in Wet Well >: Check Valves and Gate Valves Security Fencing Lockable Wet Well Cover Area Light 110V Electrical Convenience Outlet Flood/Buoyancy Protection High Water Alarm (one choice may be speed)_ Audible and Visual Auto Dialer d' ze and i material• 9. summary Diameter (in) of torte main Length (linear feet) to ve pwcmll Pipe Material U. by tameter High Elevation a Low Ele frtion Minimum Velocity Maximum Velocity Minimum Cover (in) 2 636 PVC 97.75 70 2.65 2.65 10. Are air release valves provided at all high points along the force main (must be provided where the elevation difference exceeds 10 feet)? x_ yes _ no 11. Is pump station subject to flooding? yes X no. If yes, what measures are being taken to protect against flooding? 12. If subject to flooding, specify the 100-year flood elevation: Feet MSL 13. Are there existing or planned pump stations downstream of this station? X Yes No. If yes, the engineer shall evaluate the ability of those pump stations to adequately handle the subject flows and shall include that evaluation as an attachment to this application. Pae4of8 FORM: GSPSA 11/93 s Attachment - Ref.: Poole Road Subdivision Sewer Town of Troy Pump Station Information - Page 4, Heading V, Item -13 The C&A pump station is capable of handling this small additional flow. Station carries only domestic gravity sewer for Norwood Yarns and Allendale Knitting, approximately 400 employees total. This station is monitored by the Town's SCADA system and has never given a high water alarm during any heavy rainfall. The pumps are 150 GPM. The station takes on average 45 minutes to fill. Additional flow will help this station since water usage has dropped consistently over the years. E. Gray Walls, PE This form must be completed by the appropriate DEM regional office and included as a part of the project submittal information. INSTRUCTIONS TO NC PROFESSIONAL ENGINEER: The classification of the downslope surface waters (the surface waters that any overflow from the facility would flow toward) in which these sewers will be constructed must be determined by the appropriate DEM regional office. Therefore, you are required, prior to submittal of the application package, to submit this form, with items 1 through 7 completed, to the appropriate Division of Environmental Management Regional Water Quality Supervisor (see page 8 of 8). At a minimum you must include an 8.5" by I I" copy of the portion of a 7.5 minute USGS Topographic Map which shows the location of these sewers and the downslope surface waters in which they will be located. Identify the closest downslope surface waters on the attached map copy. Once the regional office has completed the classification, reincorporate this completed page and the topographic map into the complete application form and submit the application package. 1. Applicant (specify name of the municipality, corporation, individual, etc.): Town of Troy 2. Name & complete address of engineering fi Central Carolina Engineering, PA rm: 444 North Main StTroy- Telephone number.. ( 91 0 ) 5 7 2 9 2 2 6 - 3 Project name: Poole Road Subdivision Sewer System 4. Name of closest downslope surface waters: Warner Creek 5. County(s) where sewers and surface waters are located: Montgomery 6. Map name and date: Troy. 1 982 7. NC Professional Engineer's Seal, Signature, and Date: TO: REGIONAL WATER QUALITY SUPERVISOR Please provide me with the classification of the watershed where these sewers will be constructed, as identified on the attached map segment Name of surface waters: Warner Creek. Designation supplied 3/7/94 ,, Classification (as established by the Environmental Management Commission): Proposed classification, if applicable: Signature of regional office personnel: (All aaachments must be signed) FORM: GSPSA 11/93 Page 5 of 8 Class C Date: THIS APPLICATION PACKAGE WILL NOT BE ACCEPTED BY THE DIVISION OF ENVIRONMENTAL MANAGEMENT UNLESS ALL OF THE APPLICABLE ITEMS ARE INCLUDED WITH THE SUBMITTAL Required Items a. One original and one copy of the completed and appropriately executed application form. If modifications to the form a required as a result of additional information requests by the Division, the additional information must be transmitted tmd the signature of the applicant and the actual modification must be initialed by the NC Professional Engineer. b. Two (2) sets of detailed plans and specifications signed and sealed by a North Carolina Professional Engineer. The plans mu: include a general location map, a plan view of the sewer extension, a profile of the sewer extension, and must show th proximity of the sewer extension to other utilities and natural features. Specifications may be omitted for delegate authorities. Each sheet of the plans and the first page of the specifications must be signed and sealed. Two (2) copies of th existing permit if a modification. The plans and specifications must not contain phrases (such as: FOR REVIEW ONLY NOT FOR CONSTRUCTION, etc.) that indicate that they are anything other than final plans and specifications. However the plans and specifications may contain: FINAL DESIGN - NOT RELEASED FOR CONSTRUCTION. C. Two copies of all calculations, including pump selection, friction calculations, cycle time, pump curves (including systen curves applicable with one pump running, two pumps running, three pumps running, etc.), and evaluation of downstrean pump stations. These items must be submitted under the signature and seal of the NC Professional Engineer. d. The appropriate permit processing fee, in accordance with 15A NCAC 2H .0205(c)(5). The fee for sewer extensions fa nondelegated municipalities is $400. The fee for sewer extensions for delegated municipalities (applies only to those governmental jurisdictions that have specific delegation review authority, as granted by the Environmental Managemen: Commission) is $200. Name changes without other modifications are $100. C. If the owner/authority of the wastewater treatment facility (WWTF) that will be accepting the wastewater flow from this project is different from the applicant of the project, then a letter must be provided from the owner/authority of the WWTF specifying the volume of flow that will be accepted. The letter should be a recent letter and should refer to the project by the same name as that identified on the application and the plans/specifications. L If the application is being submitted in the name of a privately owned public utility, evidence must be submitted from the Utilities Commission which demonstrates that the utility is authorized to hold the franchise for the area to be served. In the case of contiguous service areas, evidence must be provided from the Utilities Commission acknowledging these areas are covered under an existing franchise. g. A properly executed Operational Agreement (original and one copy - form provided by DEM) must be submitted if the sewer extension will be serving single family residences, condominiums, mobile homes, or town houses and if the subject sewer extension is owned by the individual residents, a homeowners association, or a developer. h. The downslope surface waters classification must be determined by the appropriate DEM regional office, using page 5 of 8 of this form, prior to the submittal of the application package to the Water Quality Permits and Engineering Unit. Once the regional office has completed the classification, page 5 of 8 should be reincorporated into the application package and the entire application package may then be submitted to Water Quality Permits and Engineering Unit. i. A cover letter, which briefly describes the project, should be included with each application package. If necessary for clarity, feel free to include attachments to the application form. Such attachments will be considered as part of the application and should be numbered to correspond to the section to which they refer. a j. All materials and fees submitted in support of this request for a permit become the property of the Division of Environmental Management; tberefore, if the permit is not issued for any reason, the Division will return submitted materials only at its option. FORM: GSPSA 11/93 Page 6 of 8 Central Carolina Engineering, PA Name and Complete Address of Engineering Fun: 444 North Main St. City: Troy State: NC zip. 27371 Telephone Number. ( 910 5 7 2— 9 2 2 6 Professional Engineer's Certification: E. Gray Walls Poole Rd. Subdivision I, , attest that this application for has been reviewed by me and is accurate and complete to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations. Although certain portions of this submittal package may have been developed by other professionals, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. North Carolina Professional Engineer's Seal, Signature, and Date: Fri Applicant's Certification: L Gray Walls attest that this application for Poole Rd. Subdivision has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. Signature Date 01 - Z i - 77 THE COMPLETED APPLICATION PACKAGE, INCLUDING ALL SUPPORTING INFORMATION AND MATERIALS, SHOULD BE SENT TO THE FOLLOWING ADDRESS: NORTH CAROLINA DIVISION OF ENVIRONMENTAL MANAGEMENT WATER QUALITY SECTION PERMITS AND ENGINEERING UNIT POST OFFICE BOX 29535 RALEIGH, NORTH CAROLINA 27626-0535 TELEPHONE NUMBER: (919) 733-5083 FORM: GSPSA 11/93 Page 7 of 8 DIVISION OF ENVIRONMENTAL MANAGEMENT REGIONAL OFFICES (11/93) Asheville Regional WQ Supervisor 59 Woodfin Place Asheville, NC 28801 (704) 251-6208 Fax (704) 251-6452 Washington Regional WQ Supervisor Post Office Box 1507 Washington, NC 27889 (919) 946-6481 Fax (919) 975-3716 Avery Macon Beaufort Jones Buncombe Madison Berrie Lenoir Bunim McDowell Camden Martin Caldwell Mitchell Chowan Pamlico Cherokee Polk Craven Pasquomnk Clay Rutherford Cuarituck Perquimans Graham Swain Date Pitt Haywood Transylvania Gates Tyrell Hendersan Yancy Greene Washington Jackson Hertford Wayne Hyde Fayetteville Regional WQ Supervisor Wacbovia Building, Suite 714 Fayetteville, NC 28301 (910) 486-1541 Fax (910) 486-0707 Mooresville Regional WQ Supervisor 919 North Main Street Mooresville, NC 28115 (704)663-1699 Fax (704) 663-6040 Raleigh Regional WQ Supervisor Post Office Box 27687 Raleigh, NC 27611 (919) 571.4700 Fax (919) 5714718 Chatham Nash Durham Northampton Edgea mbe Orange Franklin Person Granville Vance Halifax Wake Johnston Warren Lee Wilson Wilmington Region. WQ Supervisor 127 Cardinal Drive Extension Wilmington, NC 28405-3845 (910) 395-3900 Fax (910) 350-2004 Anson Moore Alexander Mecklenburg Brunswick New Hanover Bladen Robeson Cabar:us Rowan Carteret Onslow Cumberland Richmond Catawba Stanly Columbus Pender Harnett Sampson Gaston Union Duplin Hoke Scotland lredell Cleveland Montgomery Lincoln Winston-Salem Regional WQ Supervisor 8025 North Point Boulevard, Suite 100 Winston-Salem, NC 27106 (910) 896-7007 Fax (910) 896-7005 Alamance Rockingham Allegbany Randolph Ask Stokes Caswen Surly Davidson Watauga Davie Wilkes Forsyth Yadkin Guilford FORM: GSPSA 11/93 Page 8 of 8 TROY QUADRANGLE S NORTH CAROLINA—MONTGOMERY CO. 7.5 MINUTE SERIES (TOPOGRAPHIC) SW/4 TROY 15' QUADRANGLE F 598 55' 199 1 730 000 FEET '00 I 19 "3, 79°p2'30 Brans �xos�Nca�s r; 35` \,ro (• „ �a,. <. N ,Y8 i : ♦ —' --$ran 0 I, n a\ 11 ur v I (td r r: —� it 1-550 �W . • n• —� t Filtration O �V �rw1 `�'�� °I �� y • 5�cP 590 C 163 • /y Il • I e"1.. a' _ •�71t57t � I 1•ses• 1, FEET n MIT' S o Collies - -- a14 u csa1; • 1 nt C, _ l wr ( . ^tea ' � b� _ , Itaot r E"I � P E •.wN+ � s* r ///1 3� 1ViT_j tneia, *12 -_ � 1� j _ �' � � � o�, h II, fie' _, • �: I _ 1) ,, ! ' �' C •1 ' Substation ffj `-"'� x 575 fttap II h i ;.x69? If J +; /_r� - //r�-=N Sac___ _____ �• / �/� I� � � ' q :��JJ k tit, N 1 HYDR CALCS Poole Rd PS.Xis POOLE RD SUBDIVISION GRINDER PUMP STATION LOCATION :POOLE ROAD APPROX 1 MILE WEST OF NC-109 NORTH TOP OF PUMP STATION 78.25 (elev) ELEVATION BOTTOM OF WETWELL 70.00 (elev) PUMP OFF ELEVATION ABOVE BOTTOM WETWELL 71.75 (elev) ELEVATION OF FORCE MAIN DISCHARGE 97.75 (ew) ELEVATION HEAD ON PUMP 25.W (ft) DIA OF WETWELL 4.00 (ft) PUMP DOWN HEIGHT 1.50 (R) VOLUME OF WETWELL 18.85 (cf) PUMP ON ELEVATION 73.00 (elev) GALLONS TO PUMP 140.99 (gab) PIPE RUN FROM - TO: PUMPING WATER LEVEL IN WETWELL THRU BALL & CHECK VAULT DESIGN Q = 26 GPM PIPE DIA = 2 IN. CHW = 120 TOT LF OF Y PIPE = 25 (LF) 1 - 2" BALL CHECK VALVE = 2 (EQUIV LF) 1 - 7' BASE 90 DEG) = 6 (EQUIV LF) 1 - 2" 90 DEG ELBOW = 5 (EQUIV LF) 1 - 2" TRUE UNION BALL VALVE = 2 (EQUIV LF) 1 - 2" FLAPPER CHECK VALVE = 15 (EQUIV LF) 55 (LF) DeItHf2 = SUM of Dett2 = Page 3 1.154 (friction HL in feet) 1.154 (tat 2" HL in fed) HYDR CALCS Poole Rd PS.xls PIPE RUN FROM - TO: DISCHARGE SIDE OF BALL 3 CHECK VALVE VAULT TO DISCHARGE INTO GRAVITY LINE DESIGN Q = 26 GPM PIPE DIA = 2 IN. 64.4 CHW = 120 TOT LF OF 2' PVC PIPE = 645 (LF) 1 - 2' BALL VALVE = 2 (EQUIV LF) 647 (LF) DeItH2 - 13.672 (friction HL in feet) SUM of dWI2 = 13.572 (tot 2' HL in feet) TOTAL ELEV (STATIC) HEAD = 26.000 (feet) TOTAL DYNAMIC HEAD s 40.72E (feet) VELOCITY ■ 2.EE42 (ftlsec) PUMP TYPE: GRINDER MODEL M-3067 w/ a 212 IMPELLER PUMP IS 240V SINGLE PHASE PUMP MANUFACTURER: FLYGT OR APPROVED EQUAL PUMP RATED 26 GPM a 41 TDH PUMP HP 1.6 Page 4 PUMP STATION WETWELL SIZING.xls TOWN OF TROY PUMP STATION NAME: POOLE RD SUBDMSION DATE: O1/28/99 DESIGN PARAMETERS PUMPING CYCLE = PUMPING TIME + FILL TIME FOR WETWELL INFLOW = AVERAGE DAILY FLOW 3 GPM PUMPING RATE 26 GPM VOLUME OF WETWELL = ((PI*D**2)/4)*HEIGHT FT^3 HEIGHT = FROM PUMP START TO PUMP STOP 0.75 FT D = DIAMETER OF WETWELL 4.00 FT PUMPING TIME _ (VOL OF WETWELL + (INFLOW + PUMPING TIME))/PUMPING RATE PUMPING TIME = VOLUME OF WETWELL/(PUMPING RATE -INFLOW) VOLUME OF WETWELL = 9.42 FT^3 VOLUME OF WETWELL = 70.50 GAL PUMPING TIME = 3.07 MIN TIME TO FILL WETWELL = 23.50 MIN PUMPING CYCLE = 26.57 MIN < 30 MIN PUMP RUN TIME PERCENTAGE CYCLES PER HOUR = 2.26 PUMP TIME ON PER HOUR = 6.92 MIN/HR PERCENT STATION RUN TIME = 11.54% Page 1 W. Cn ..i TOTAL HEAD FEET O O O In C3 r- bf L a Limited to intemrttent duty S = Risk of sedimeMation at velocity below 2 fVsec. CIE INPUT KW 0 7.� mmN ml�m