Loading...
HomeMy WebLinkAboutNC0047091_STAFF REPORT_20031204 NPDES DOCUMENT SCANNING COVER SHEET 8 NPDES Permit: NC0047091 Silver Maples WWTP Document Type: Permit Issuance Wasteload Allocation Authorization to Construct (AtC) Permit Modification Speculative Limits Report ' Instream Assessment (67B) aEnvironmental Assessment (EA) ' Permit History Document Date: December 4, 2003 �s document is printed on reuse paper-more any content on the reverse Bide SOC PRIORITY PROJECT: NO To: Permits and Engineering Unit Water Quality Section DEC 8 2003 Attention:—Charles-Weaver Date: December.4, 2003 NPDES STAFF REPORT AND RECOMMENDATIONS County: Cabarrus NPDES Permit No.: NC0047091 MRO No.: 03-071 PART I - GENERAL INFORMATION 1. Facility and address: Silver Maples Mobile Estates WWTP 2812 Plantation Road Harrisburg, North Carolina 28057 2. Date of investigation: August 4, 2003 3. Report prepared by: B. Dee Browder, Environ. Eng. I 4. Person contacted and telephone number: Eddie Turner, (704)643-0078 5. Directions to site: From the jct. of Hwy. 29 and Pitt School Road, northeast of the Town of Harrisburg, travel west on Pitt School Road approximately 1 mile to the junction with Plantation Road. Turn right on Plantation Road and proceed to the intersection with Darwin Road. Turn left on Darwin Road and Travel 200 feet to the WWTP. 6. Discharge point(s), List for all discharge points: - Latitude: 35 22' 12" Longitude: 80 41' 00" Attach a USGS Map Extract and indicate treatment plant site and discharge point on map. N/A USGS Quad No.: F 16 SW Harrisburg, NC 7. Site size and expansion area consistent with application: Yes. 8. Topography (relationship to flood plain included): Facility is located in the 100 year flood plain. Slopes range from 8 to 10%. Page Two - 9. Location of nearest dwelling: Approx. 300 feet from the WWTP site. 10. Receiving stream or affected surface waters: Rocky River a. Classification: C b. River Basin and Subbasin No.: Yadkin 03-07-11 C. Describe receiving stream features and pertinent downstream uses: This receiving stream has considerable flow. There are other discharges located downstream of this facility (NC0063762). General C classifications uses downstream. PART H-DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of wastewater: 0.04 MGD (Design Capacity) b. What is the current permitted capacity: 0.04 MGD C. Actual treatment capacity of current facility (current design capacity): 0.04 MGD d. Date(s) and construction activities allowed by previous ATCs issued in the previous two years: N/A C. Description of existing or substantially constructed WWT facilities: The existing WWT facilities consist of a contact stabilization wastewater treatment plant, which includes a grit/surge tank followed by primary clarification, aeration, re-aeration, final clarification, chlorination, effluent flow measurement and an aerated sludge holding tank. f. Description of proposed WWT facilities: N/A g. Possible toxic impacts to surface waters: There are no toxic impacts expected. Chlorine is added to the waste stream It. Pretreatment program(POTWs only): Not Needed. 2. Residual handling and utilization/disposal scheme: Residuals are pumped by Liquid Waste, Inc and disposed of at the Rocky River Wastewater Treatment Plant. a. If residuals are being land applied specify DEM Permit No. N/A. Residuals contractor: N/A Telephone No. ( )N/A b. Residuals stabilization: PSRP PFRP N/A c. Landfill: N/A 3. Treatment plant classification: Class II (no change from previous rating). Page Three 4. SIC Code(s): 4952 Wastewater Code(s): 05 5. MTU Code(s): 04524 PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved (municipals only)? No 2. Special monitoring or limitations (including tonicity) requests: None at this time. 3. Important SOC/JOC or compliance schedule dates: N/A Submission of plans and specifications Begin construction Complete construction 4. Alternative analysis evaluation a. Spray irrigation: N/A b. Connect to regional sewer system: May be available. C. Subsurface: N/A d. Other disposal options: N/A PART IV - EVALUATION AND RECOMMENDATIONS Proper signs for notification in the event of a problem should be installed at the pump stations associated with this plant's collection system. There are significant indications of poor collection system infrastructure. A municipal collection system line is within 300 feet of this facility. It is recommended that this facility connect to the municipal collection system. The wastewater treatment plant is in very poor physical condition with rusted walking grates and damaged security fencing. It is located in a very low area and is subject to flooding. This office recommends renewal of the permit but also recommends that the facility owner address the condition of the collection system and the WWTP facility's physical condition. /y4 a3 Signature of Report fPreparer lbate Water Quality Regional Supervisor Date hAsAdsrrn.du