HomeMy WebLinkAbout020003_Compliance Evaluation Inspection_20190409ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
LINDA CULPEPPER
Director
Donald G. Payne
Payne Dairy
4566 Paul Payne Store Road
Taylorsville, NC 28681
Dear Mr. Payne:
NORTH CAROLINA
Environmental Quality
April 9, 2019
Re: COMPLIANCE INSPECTION
Payne Dairy/Facility 02-03
General Permit AWCO20003
Alexander County
On March 14, 2019, staff of the North Carolina Division of Water Resources (DWR), Water
Quality Regional Operations Section (WQROS), inspected the Payne Dairy and the permitted
waste disposal system. We wish to thank Myles G. Payne, who was present and assisted during
the inspection.
The enclosed report should be self-explanatory; however, should you have any questions
concerning this report, please contact Mr. Bealle or me at (704) 663-1699.
Sincerely,
DocuSigned by:
A wNN l-ft
F161 FB69A2D84A3...
Andrew H. Pitner, P.G., Assistant Regional Supervisor
Mooresville Regional Office
Water Quality Regional Operations Section
Division of Water Resources
enclosure: Compliance Inspection Report dated March 14, 2019
jb
NORTH CAROLIN0.D ��� Q>
�epemnem Mendrpimrn4i eueiih\ !�
North Carolina Department of Environmental Quality I Division of Water Resources
Mooresville Regional Office 1 610 East Center Avenue, Suite 301 1 Mooresville, North Carolina 28115
704.663.1699
Division of Water Resources
❑ Division of Soil and Water Conservation
❑ Other Agency
Facility Number: 020003 Facility Status: Active Permit: AWCO20003 ❑ Denied Access
Inspection Type: Compliance Inspection Inactive Or Closed Date:
Reason for Visit: Routine County: Alexander Region: Mooresville
Date of Visit: 03/14/2019 Entry Time: 03:30 pm Exit Time: 5:00 pm Incident #:
Farm Name: Payne Dairy Owner Email:
Owner: Donald G Payne Phone: 828-632-9223
Mailing Address: 4566 Paul Payne Store Rd Taylorsville NC 28681
Physical Address: 4566 Paul Payne Store Rd Taylorsville NC 28681
Facility Status: 0Compliant ❑ Not Compliant Integrator:
Location of Farm: Latitude: 35' 52' 26"
4.5 miles south of Taylorsville on SR 1605 (Paul Payne Rd.). Farm is on the west side of road.
Longitude: 81 ° 08' 29"
Question Areas:
Dischrge & Stream Impacts Waste Col, Stor, & Treat Waste Application
Records and Documents Other Issues
Certified Operator: Donald G Payne Operator Certification Number: 20977
Secondary OIC(s):
On -Site Representative(s): Name Title Phone
24 hour contact name Donald G. Payne 828-632-9223
On -site representative Myles G. Payne DocuSl ned by: 828-632-9223
Primary Inspector: James Bealle Phone: 704-663-1699 Ext.2
Inspector Signature: Date: 4/9/2019
Secondary Inspector(s): L�C2AF677B45DWB...
Inspection Summary:
07/31/18 > Waste Analysis > N = 0.72 Lbs/1000 Gallons
03/19/18 > Waste Analysis > N = 0.44 Lbs/1000 Gallons
03/08/17 > Soil Analysis
DS
Page 1 of 5
Permit: AWCO20003 Owner: Donald G Payne Facility Number: 020003
Inspection Date: 03/14/19 Inspection Type: Compliance Inspection Reason for Visit: Routine
Regulated Operations
Design Capacity
Current promotions
Cattle
Cattle - Milk Cow 500 I 200
Total Design Capacity: 500
Total SSLW: 700,000
Waste Structures
Effective Built Closed Designated Observed
Type Identifier Date Date Date Freeboard Freeboard
Waste Pond
HEIFER WSP
04/27/2005
31.20
48.00
Waste Pond
MILK BARN WSP
04/27/2005
78.00
48.00
Page 2 of 5
Permit: AWCO20003 Owner: Donald G Payne
Facility Number:
020003
Inspection Date: 03/14/19 Inspection Type: Compliance Inspection
Reason for Visit:
Routine
Discharges & Stream Impacts
Yes
No NA NE
1. Is any discharge observed from any part of the operation?
❑
MEIEI
Discharge originated at:
Structure
❑
Application Field
❑
Other
❑
a. Was conveyance man-made?
❑
❑ 0
❑
b. Did discharge reach Waters of the State? (if yes, notify DWQ)
❑
❑ 0
❑
c. What is the estimated volume that reached waters of the State (gallons)?
d. Does discharge bypass the waste management system? (if yes, notify DWQ)
❑
❑ 0
❑
2. Is there evidence of a past discharge from any part of the operation?
❑
0 ❑
❑
3. Were there any observable adverse impacts or potential adverse impacts to Waters
of the ❑
0 ❑
❑
State other than from a discharge?
Waste Collection, Storage & Treatment
Yes
No NA NE
4. Is storage capacity less than adequate?
❑
0 ❑
❑
If yes, is waste level into structural freeboard?
❑
5. Are there any immediate threats to the integrity of any of the structures observed (Le./ large
❑
0 ❑
❑
trees, severe erosion, seepage, etc.)?
6. Are there structures on -site that are not properly addressed and/or managed through a
❑
MEI
❑
waste management or closure plan?
7. Do any of the structures need maintenance or improvement?
❑
MEI
❑
8. Do any of the structures lack adequate markers as required by the permit? (Not applicable
❑
0 ❑
❑
to roofed pits, dry stacks and/or wet stacks)
9. Does any part of the waste management system other than the waste structures require
❑
0 ❑
❑
maintenance or improvement?
Waste Application
Yes No NA NE
10. Are there any required buffers, setbacks, or compliance alternatives that need
❑ 0 ❑ ❑
maintenance or improvement?
11. Is there evidence of incorrect application?
❑ 0 ❑ ❑
If yes, check the appropriate box below.
Excessive Ponding?
❑
Hydraulic Overload?
❑
Frozen Ground?
❑
Heavy metals (Cu, Zn, etc)?
❑
PAN?
❑
Is PAN > 10%/10 lbs.?
❑
Total Phosphorus?
❑
Failure to incorporate manure/sludge into bare soil?
❑
Outside of acceptable crop window?
❑
Evidence of wind drift?
❑
Application outside of application area?
❑
Crop Type 1
Corn (Silage)
Page 3 of 5
Permit: AWCO20003 Owner: Donald G Payne
Inspection Date: 03/14/19 Inspection Type: Compliance Inspection
Facility Number:
Reason for Visit:
020003
Routine
Waste Application
Yes
No NA NE
Crop Type 2
Fescue (Hay, Pasture)
Crop Type 3
Small Grain (Wheat,
Barley,
Oats)
Crop Type 4
Soybeans
Crop Type 5
Crop Type 6
Soil Type 1
Soil Type 2
Soil Type 3
Soil Type 4
Soil Type 5
Soil Type 6
14. Do the receiving crops differ from those designated in the Certified Animal Waste
❑
0 ❑
❑
Management Plan(CAWMP)?
15. Does the receiving crop and/or land application site need improvement?
❑
0 ❑
❑
16. Did the facility fail to secure and/or operate per the irrigation design or wettable acre
❑
0 ❑
❑
determination?
17. Does the facility lack adequate acreage for land application?
❑
0 ❑
❑
18. Is there a lack of properly operating waste application equipment?
❑
0 ❑
❑
Records and Documents
Yes
No NA NE
19. Did the facility fail to have Certificate of Coverage and Permit readily available?
❑
0 ❑
❑
20. Does the facility fail to have all components of the CAWMP readily available?
❑
0 ❑
❑
If yes, check the appropriate box below.
WUP?
❑
Checklists?
❑
Design?
❑
Maps?
❑
Lease Agreements?
❑
Other?
❑
If Other, please specify
21. Does record keeping need improvement?
❑
❑
❑
If yes, check the appropriate box below.
Waste Application?
❑
Weekly Freeboard?
❑
Waste Analysis?
❑
Soil analysis?
❑
Waste Transfers?
❑
Weather code?
❑
Rainfall?
❑
Stocking?
❑
Page 4 of 5
Permit: AWCO20003 Owner: Donald G Payne Facility Number:
Inspection Date: 03/14/19 Inspection Type: Compliance Inspection Reason for Visit:
020003
Routine
Records and Documents
Yes
No NA NE
Crop yields?
❑
120 Minute inspections?
❑
Monthly and 1" Rainfall Inspections
❑
Sludge Survey
❑
22. Did the facility fail to install and maintain a rain gauge?
❑
0 ❑
❑
23. If selected, did the facility fail to install and maintain a rainbreaker on irrigation equipment
❑
❑ 0
❑
(NPDES only)?
24. Did the facility fail to calibrate waste application equipment as required by the permit?
❑
❑
❑
25. Is the facility out of compliance with permit conditions related to sludge? If yes, check the
❑
❑
❑
appropriate box(es) below:
Failure to complete annual sludge survey
❑
Failure to develop a POA for sludge levels
❑
Non -compliant sludge levels in any lagoon
❑
List structure(s) and date of first survey indicating non-compliance:
26. Did the facility fail to provide documentation of an actively certified operator in charge?
❑
❑
❑
27. Did the facility fail to secure a phosphorous loss assessment (PLAT) certification?
❑
❑ 0
❑
Other Issues
Yes
No NA NE
28. Did the facility fail to properly dispose of dead animals within 24 hours and/or document
❑
❑
❑
and report mortality rates that exceed normal rates?
29. At the time of the inspection did the facility pose an odor or air quality concern? If yes,
❑
❑
❑
contact a regional Air Quality representative immediately.
30. Did the facility fail to notify regional DWQ of emergency situations as required by Permit?
❑
0 ❑
❑
(i.e., discharge, freeboard problems, over -application)
31. Do subsurface tile drains exist at the facility?
❑
0 ❑
❑
If yes, check the appropriate box below.
Application Field
❑
Lagoon / Storage Pond
❑
Other
❑
If Other, please specify
32. Were any additional problems noted which cause non-compliance of the Permit or
❑
0 ❑
❑
CAW M P?
33. Did the Reviewer/Inspector fail to discuss review/inspection with on -site representative?
❑
0 ❑
❑
34. Does the facility require a follow-up visit by same agency?
❑
0 ❑
❑
Page 5 of 5