HomeMy WebLinkAbout20180582 Ver 2_More Info Received_20200326
Project area
Legend
Feet
Proposed dredging area
01,0002,0004,000
SOURCE
FIGURE 1
SITELOCATION MAP
USGS
7.5-minute Topographic Quadrangles
Cashiers Canoe Club
Cashiers, North Carolina (1997)Cashiers, Jackson County
Contour Interval = 40 feet
North Carolina
Date:
11/25/2019
Headwater Project # A-1
1 inch = 2,000 feet
Prepared by:
NJC
Cashiers Lake
Legend
Proposeddredging area
Former Metco plant location
Surface waters
River
hattooga
C
Feet
Note: This is not a survey. All locations are approximate.
0200400800
SOURCE
FIGURE2
NC One Map
MAP
Orthoimagery (2015)
Cashiers Canoe Club
ArcGIS Online
Cashiers, Jackson County
//
Date:
Waterbodies and Rivers of Jackson
NorthCarolina
County, NC
HeadwaterProject#A-1
NJC
Prepared by:1 inch = 400 feet
BG-2
SB-3
S-1
S-3
S-2
SB-1
S-6
BG-1
S-7
S-4
S-5
S-8
S-9
S-10
S-11
S-12
SB-2
S-14
S-13
S-15
Legend
Proposed dredging area
Cashiers Lake
Surface waters
2020 dredge sampling location
Headwater 2018 sampling location
Feet
Note: This is not a survey. All locations are approximate.
0100200400
SOURCE
FIGURE 3
NC One Map
DREDGE SAMPLE LOCATION
Orthoimagery (2015) and NC Routes
MAP
Cashiers Canoe Club
ArcGIS Online
Cashiers, Jackson County
Date:3/3/2020
Waterbodies and Rivers of Jackson
North Carolina
County, NC
Headwater Project # A20-111
Prepared by:NJC
1 inch = 200 feet
#=CL#
Pace Analytical Services, LLC
2225 Riverside Dr.
Asheville, NC 28804
(828)254-7176
LIMS USE: FR - ADAM TRIPP
LIMS OBJECT ID: 92470098
March 23, 2020
Mr. Adam Tripp
Headwater Environmental, Inc.
43 College Place, Suite 212
Asheville, NC 28801
RE:Project:
CASHIERS 3-18-2020
Pace Project No.:92470098
Dear Mr. Tripp:
Enclosed are the analytical results for sample(s) received by the laboratory on March 18, 2020. The
results relate only to the samples included in this report. Results reported herein conform to the most
current, applicable TNI/NELAC standards and the laboratory's Quality Assurance Manual, where
applicable, unless otherwise noted in the body of the report.
If you have any questions concerning this report, please feel free to contact me.
Sincerely,
Lorri Patton
lorri.patton@pacelabs.com
1(828)254-7176
Project Manager
Enclosures
cc:Mr. Adam Tripp, Headwater Environmental, Inc.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.
Page 1 of 8
#=CP#
Pace Analytical Services, LLC
2225 Riverside Dr.
Asheville, NC 28804
(828)254-7176
CERTIFICATIONS
Project:CASHIERS 3-18-2020
Pace Project No.:92470098
Pace Analytical Services Charlotte
9800 Kincey Ave. Ste 100, Huntersville, NC 28078South Carolina Certification #: 99006001
Louisiana/NELAP Certification # LA170028Florida/NELAP Certification #: E87627
North Carolina Drinking Water Certification #: 37706Kentucky UST Certification #: 84
North Carolina Field Services Certification #: 5342Virginia/VELAP Certification #: 460221
North Carolina Wastewater Certification #: 12
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.
Page 2 of 8
#=SA#
Pace Analytical Services, LLC
2225 Riverside Dr.
Asheville, NC 28804
(828)254-7176
SAMPLE ANALYTE COUNT
Project:CASHIERS 3-18-2020
Pace Project No.:92470098
Analytes
Lab IDSample IDMethodAnalystsReportedLaboratory
92470098001S-12 REPA 8270E by SIMPKS3PASI-C
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
without the written consent of Pace Analytical Services, LLC.
Page 3 of 8
#=AR#
Pace Analytical Services, LLC
2225 Riverside Dr.
Asheville, NC 28804
(828)254-7176
ANALYTICAL RESULTS
Project:CASHIERS 3-18-2020
Pace Project No.:92470098
Sample:S-12 RLab ID:92470098001Collected:03/18/20 12:45Received:03/18/20 16:30Matrix:Solid
Results reported on a "dry weight" basis and are adjusted for percent moisture, sample size and any dilutions.
ParametersResultsUnitsReport LimitDFPreparedAnalyzedCAS No.Qual
Analytical Method: EPA 8270E by SIM Preparation Method: EPA 3511
8270E SPLP SIM PAH Low Volume
1-MethylnaphthaleneNDug/L0.80103/23/20 10:3003/23/20 11:2990-12-0M1
Surrogates
Nitrobenzene-d5 (S)125%57-164103/23/20 10:3003/23/20 11:294165-60-0
2-Fluorobiphenyl (S)122%45-150103/23/20 10:3003/23/20 11:29321-60-8
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
Date: 03/23/2020 02:23 PM without the written consent of Pace Analytical Services, LLC.
Page 4 of 8
#=QC#
Pace Analytical Services, LLC
2225 Riverside Dr.
Asheville, NC 28804
(828)254-7176
QUALITY CONTROL DATA
Project:CASHIERS 3-18-2020
Pace Project No.:92470098
QC Batch:531885Analysis Method:EPA 8270E by SIM
QC Batch Method:EPA 3511Analysis Description:8270E SPLP SIM PAH Low Volume
Associated Lab Samples:92470098001
METHOD BLANK:2837688Matrix:Water
Associated Lab Samples:
92470098001
BlankReporting
ParameterUnitsResultLimitAnalyzedQualifiers
1-Methylnaphthaleneug/LND0.8003/23/20 10:44
2-Fluorobiphenyl (S)%13145-15003/23/20 10:44
Nitrobenzene-d5 (S)%14357-16403/23/20 10:44
LABORATORY CONTROL SAMPLE:2839639
SpikeLCSLCS% Rec
ParameterUnitsConc.Result% RecLimitsQualifiers
1-Methylnaphthaleneug/L2.53.012070-130
2-Fluorobiphenyl (S)%14145-150
Nitrobenzene-d5 (S)%14457-164
MATRIX SPIKE & MATRIX SPIKE DUPLICATE:28396402839641
MSMSD
92470098001SpikeSpikeMSMSDMSMSD% Rec
ParameterUnitsResultConc.Conc.ResultResult% Rec% RecLimitsRPDQual
ND
1-Methylnaphthaleneug/L2.52.53.63.614414370-1301M1
2-Fluorobiphenyl (S)%15915845-150S0
Nitrobenzene-d5 (S)%16816357-164S0
Results presented on this page are in the units indicated by the "Units" column except where an alternate unit is presented to the right of the result.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
Date: 03/23/2020 02:23 PM without the written consent of Pace Analytical Services, LLC.
Page 5 of 8
#=QL#
Pace Analytical Services, LLC
2225 Riverside Dr.
Asheville, NC 28804
(828)254-7176
QUALIFIERS
Project:CASHIERS 3-18-2020
Pace Project No.:92470098
DEFINITIONS
DF - Dilution Factor, if reported, represents the factor applied to the reported data due to dilution of the sample aliquot.
ND - Not Detected at or above adjusted reporting limit.
TNTC - Too Numerous To Count
J - Estimated concentration above the adjusted method detection limit and below the adjusted reporting limit.
MDL - Adjusted Method Detection Limit.
PQL - Practical Quantitation Limit.
RL - Reporting Limit - The lowest concentration value that meets project requirements for quantitative data with known precision and
bias for a specific analyte in a specific matrix.
S - Surrogate
1,2-Diphenylhydrazine decomposes to and cannot be separated from Azobenzene using Method 8270. The result for each analyte is
a combined concentration.
Consistent with EPA guidelines, unrounded data are displayed and have been used to calculate % recovery and RPD values.
LCS(D) - Laboratory Control Sample (Duplicate)
MS(D) - Matrix Spike (Duplicate)
DUP - Sample Duplicate
RPD - Relative Percent Difference
NC - Not Calculable.
SG - Silica Gel - Clean-Up
U - Indicates the compound was analyzed for, but not detected.
Acid preservation may not be appropriate for 2 Chloroethylvinyl ether.
A separate vial preserved to a pH of 4-5 is recommended in SW846 Chapter 4 for the analysis of Acrolein and Acrylonitrile by EPA
Method 8260.
N-Nitrosodiphenylamine decomposes and cannot be separated from Diphenylamine using Method 8270. The result reported for
each analyte is a combined concentration.
Pace Analytical is TNI accredited. Contact your Pace PM for the current list of accredited analytes.
TNI - The NELAC Institute.
LABORATORIES
PASI-CPace Analytical Services - Charlotte
ANALYTE QUALIFIERS
M1Matrix spike recovery exceeded QC limits. Batch accepted based on laboratory control sample (LCS) recovery.
S0Surrogate recovery outside laboratory control limits.
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
Date: 03/23/2020 02:23 PM without the written consent of Pace Analytical Services, LLC.
Page 6 of 8
#=CR#
Pace Analytical Services, LLC
2225 Riverside Dr.
Asheville, NC 28804
(828)254-7176
QUALITY CONTROL DATA CROSS REFERENCE TABLE
Project:CASHIERS 3-18-2020
Pace Project No.:92470098
Analytical
Lab IDSample IDQC Batch MethodQC BatchAnalytical MethodBatch
92470098001S-12 REPA 3511531885EPA 8270E by SIM531936
REPORT OF LABORATORY ANALYSIS
This report shall not be reproduced, except in full,
Date: 03/23/2020 02:23 PM without the written consent of Pace Analytical Services, LLC.
Page 7 of 8