Loading...
HomeMy WebLinkAboutNC0032867_Inspection_20180105United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 u 3 I NCO032867 111 121 18/01/05 I17 18 U 19 I s I 201 I 211IIIII 111111III II III III1 I I IIIII IIIIIIIII II r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 1.0 70J 711„ I 72 L.71 74 79 I I I I 80 Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 01:30PM 18/01/05 14/01/01 Kings Mountain Travel Plaza 400 Dixon School Rd Exit Time/Date Permit Expiration Date Kings Mountain NC 28086 02:30PM 18/01/05 18/08/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Ken Deaver,PO Box 63 Rutherfordton NC 281390063/ORC/828-657-1810/8286574664 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Flow Measurement 0 Operations & Maintenar 0 Facility Site Review 0 Effluent/Receiving Wate Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Wes Bell DWR/MRO WQ/704-663-1699 Ext.2192/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO032867 I11 12I 18/01/05 117 18 IRI (Cont.) Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) The wastewater treatment plant was not being properly operated and maintained. The following observations were noted during the site inspection: - Untreated wastewater had accumulated on the ground beside the leaking septic tanks; - No aeration was being provided in one of the aeration basin trains due to inoperable blower/motor units (2-total). Note: Influent flow was entering both aeration basin trains; - The wastewater in the inoperable aeration basin train was septic due to lack of aeration; - The microbial population in the operable aeration basin appeared very low; - Flow meter had not been calibrated in over a year; - The strip chart recording device on flow meter was not operational; - The effluent ammonia sample (67 mg/L) exceeded the permit limit; - The effluent appeared turbid with suspended solids Page# Permit: NCO032867 Inspection Date: 01/05/2018 Owner -Facility: Kings Mountain Travel Plaza Inspection Type: Reconnaissance Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Yes No NA NE Page#