Loading...
HomeMy WebLinkAboutNC0024244_Inspection_20180813United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 2 u 3 I NCO024244 111 121 18/08/13 I17 18 I R I 19 I s I 20L] 21111I I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I r6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 67 I 72 I n, I 73 i I 74 79 I I I I I I I80 70 I I 71 I LL -1 I I LJ Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 03:16PM 18/08/13 13/01/01 Long Creek WWTP 1040 Coble Ave Extension Exit Time/Date Permit Expiration Date Albemarle NC 28002 03:58PM 18/08/13 14/02/28 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Brandon Wesley Plyler/ORC/704-984-9630/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Michael J Ferris,PO Box 190 Albemarle NC 280020190/City Manager/704-984-9410/7049849406 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Other Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Roberto Scheller DWR/MRO WQ/252-946-6481/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date W. Corey Basinger DWR/MRO WQ/704-235-2194/ EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type (Cont.) NCO024244 I11 12I 18/08/13 117 18 IRI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) This facility reported loss of power the night of August 11, 2018 and the morning of August 12, 2018 between 11:00 pm and 07:00 am as the result of a thunderstorm. The standby generator did not start up and, as a result, 478,333 gallons of partially treated sewage overflowed a lift station and went into Long Creek. It was noted at time of site visit that generator is a 1972 model generator with manual switch gear. Please be advised, that in accordance with 15A North Carolina Administrative Code (NCAC) 2H .0124, Reliability, "All facilities shall provide adequate measures, which, in the opinion of the Director, will insure continued treatment and disinfection where the interruption of such treatment would render the waters unsafe for their best intended uses. The relibility measures shall include... (2)(a) dual or standby power supply on site" Also in accordance with NPDES Permit NC0024244, Part II, Section C, Item 4. Bypassing of Treatment Facilities,(c.)(1) Prohibition of Bypass, "Bypass from the treatment facility is prohibited and the Permit Issuing Authority may take enforcement action against a Permittee for bypass..." Page# Permit: NCO024244 Inspection Date: 08/13/2018 Other Comment: Owner -Facility: Long Creek WWTP Inspection Type: Reconnaissance Yes No NA NE Page#