Loading...
HomeMy WebLinkAboutNCG080832_Rescission Request_20200320 w FOR AGENCY USE ONLY Division of Energy,Mineral& Land Resources Date Received Land Quality Section/Stormwater Permitting Program Year Month Day National Pollutant Discharge Elimination System Environmental Quality RESCISSION REQUEST FORM Please fill out and return this form if you no longer need to maintain your NPDES stormwater permit. 1) Enter the permit number to which this request applies: Individual Permit (or) Certificate of Coverage N C S N 0 0 0 8 0 8 3 2 2) Owner/Facility Information: *Final correspondence will be mailed to the address noted below Owner/Facility Name Norfolk Southern/Gastonia DTL Fuel Site Facility Contact Adam Motsinger Street Address 350 Hancock Street City Gastonia State NC ZIP Code 28054 County Gaston E-mail Address adam.motsinger@nscorp.com Telephone No. (704) 378-3841 Fax: (678) 512-5128 3) Reason for rescission request(This is required information. Attach separate sheet if necessary): ❑ Facility closed or is closing on _ . All industrial activities have ceased such that no discharges of stormwater are contaminated by exposure to industrial activities or materials. ❑ Facility sold to on . If the facility will continue operations under the new owner it may be more appropriate to request an ownership change to reissue to permit to the new owner. ❑✓ Other: The activities at this site do not meet the definition of a non transient facility with a vehicle maintenance shop or equipment cleaning operations and therefore are not included in the transportation maintenance category per 40 CFR 122.26(b)(14)(viii). As a result the facility does not require a NPDES Stormwater Permit. 4) Certification: I, as an authorized representative, hereby request rescission of coverage under the NPDES Stormwater Permit for the subject facility. I am familiar with the information contained in this request and to the best of my knowledge and belief such information is true, complete and accurate. Signature Date '3/4r/2 Joseph Williams Director Environmental Compliance Print or type name of person signing above Title Please return this completed rescission request form to: DEMLR- Stormwater Program Dept. of Environmental Quality 1612 Mail Service Center Raleigh, North Carolina 27699-1612 Revised 2018Jan10 • TIR Suite50 International Dr. T 864.281.0030 150 TRCcomp anies.com Greenville.SC 29615 Technical Memorandum Date: February 18, 2020, To: Terri Allen Norfolk Southern Railway Company From: Daniel Curry Senior Client Executive Subject: Gastonia DTL Fuel Site Stormwater NPDES Determination of Non- Applicability (DONA) and Notice of Termination cc: Scott Menniti Project No.: 322467.0020.0000 Norfolk Southern Railroad Company (NSRC) is requesting termination of coverage of the National Pollutant Discharge Elimination System (NPDES) General Permit for Storm Water Discharges Associated with Vehicle Maintenance Areas (General Permit No. NCG080000) for the Gastonia DTL Fuel Site, located at 350 Hancock Street, Gastonia, North Carolina 28054. Summary TRC has reviewed the definition of"Storm Water discharge associated with Industrial Activity," specifically as defined for the transportation sector, "Transportation facilities classified as Standard Industrial Classifications 40, 41, 42 (except 4221-25), 43, 44, 45, and 5171 which have vehicle maintenance shops, equipment cleaning operations, or airport deicing operations"found in 40 CFR 122.26(b)(14)(viii), and incorporated into North Carolina regulations by reference (15A NCAC 02H.0126). The definition specifically mentions, "fueling" as an applicable "vehicle maintenance" activity that could subject the facility to regulation by the General Permit. TRC understands that Direct to Locomotive (DTL) fueling is being performed onsite. NSRC has done extensive legal research into the obligation to permit DTL fueling activities. TRC's understanding of NSRC's legal determination is that maintenance (including fueling) outside designated maintenance areas is not regulated as vehicle maintenance. For maintenance (including fueling) to be included in the transportation category, it must take place at a non-transient location. NSRC's interpretation of this determination is that if DTL fueling is taking place on the mainline track or a siding track, at a location which otherwise does not concentrate trains, have vehicle maintenance shops or equipment cleaning operations then the site is transient and therefore not considered a facility as defined by the transportation sector permit. As such these sites do not require an NPDES Stormwater permit. TRC has performed a site visit. The Gastonia DTL Fuel Site is a siding track that does not concentrate trains, otherwise have a maintenance shop or car equipment cleaning operations. Based on NSRC's legal determination, TRC is submitting a Rescission Request Form for the NPDES General Permit for Storm Water Discharges Associated with Vehicle Maintenance Areas (General Permit No. NCG080000) for the Gastonia Site. \\greenville-fp1\WPGVL\PJT2\322467\Gastonia DTL\February 2020 Flnal\Final Gastonia DTL Site NPDES DONA_Feb 2020.docx I` ��c 50 International Drive T 864.281.0030 , Suite 150 TRCcompanies.com Greenville,SC 29615 Technical Certification To: Terri Allen Norfolk Southern Railway Company From: Daniel A.Curry Senior Client Executive Subject: Gastonia DTL Fuel Site Stormwater NPDES Determination of Non-Applicability(DONA)and Notice of Termination Gastonia, North Carolina Date: February 18,2020 Project No.: 322467.0020.0000 002018 The following documents and attachments are required for the Gastonia DTL Fuel Site Stormwater NPDES Notice of Termination: Gastonia DTL Fuel Site Stormwater NPDES Determination of Non-Applicability(DONA) North Carolina NPDES Rescission Request Form for Storm Water Discharges Associated with Vehicle Maintenance Areas(General Permit No. NCG080000)for Storm Water Discharges Associated with Vehicle Maintenance Areas (General Permit No. NCG080000)for the Gastonia DTL Fuel Site, located at 350 Hancock Street, Gastonia, North Carolina 28054. 1 certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate, and complete. lam aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. TRC Environmental Corp. February 18, 2020 nie A. Curry, P.E. Date Senior Client Executive \\GREENVILLE-FP1\W PGVL\PJT2\322467\GASTONIA DTL\NOVEMBER 2019 FINAL\TRC FORMS\GASTONIA SW DONA TRC CERTIFICATION NOV 2019 FINAL.DOCX ,' c 50 International Dr. T 864.281.0030 Suite 150 TRCcomp anies.com Greenville, SC 29615 March 18, 2020 DEMLR—Stormwater Program RECEIVED Department of Environmental Quality 1612 Mail Service Center MAR 2 0 2020 Raleigh, NC 27699-1612 DENR-LAND QUALITY STORMWATER PERMITTING Subject: Rescission Request Form Norfolk Southern Railway Company(NSRC)—Gastonia and Kannapolis DTL Sites Dear Sir or Madam: On behalf of Norfolk Southern Company(NS),TRC Environmental Corporation is submitting the attached Rescission Request forms for the Gastonia DTL Fuel Site and the Kannapolis DTL Fuel Site. The activities at these sites do not meet the definition of a non-transient facility with a vehicle maintenance shop or equipment cleaning operations and therefore are not included in the transportation maintenance category per 40 CFR 122.26(b)(14)(viii). As a result, neither of these sites require a NPDES Stormwater Permit. Should you have any questions, please do not hesitate to contact me at 864.787.7923 or DCurry@trccompanies.com. Sincerely, C Environmental Corporation rue A Curry Senior Client Executive Attachments cc: Terri Allen—Norfolk Southern \\GREENVILLE-FPI\WPGVL\P1T2\322467\GASTONIA DTL\GASTONIA DTL RECEISSION REQUEST COVER LETTER.DOCX