Loading...
HomeMy WebLinkAboutNC0021491_Pretreatment_Annual_Report_20200319Pretreatment Program Info Database printed on: 12/20/2019 for Program Name Mocksville WWTP Name Dutchman Program Approval Date 01/14/1985 Pretreatment Status Modified Region WSRO County Davie Stream Information ► IWC % at 7Q10 37.39 7Q10 Flow cfs / mgd 2.54 / 1.64 1 Q10 Flow cfs / mgd 2.13 / 1.37 Stream Classification C Basin Number YAD05 Receiving Stream Name DUTCHMAN CREEK NPDES Number NC0021491 NPDES Effective Date Last PAR Rec 02/26/2019 PAR Due Date 03/01/2020 mercury 11 /01 /2014 1631 NPDES Expire Date p� 06/30/2019 Current Fiscal 04/10/2019 required Year PCI Done POTW is Primary WWTP TRUE Last Audit on 09/23/2008 Audit Year Next17/18 yes Design Flow mgd 0.9800 % Design mgd is SIU permitted 13.78 Permitted SIU flow (mgd) [Pt_SIU) 135 WWTP SIU's 1 Program SIUs 1 WWTP CIU's 0 Program CIUs10 I HWA LTMP IWS SUO ERP date Inactive Date Next Due 12/01/2020 12/31/2019 Date Received by DWR 12/17/2015 08/28/2018 12/02/2014 06/11/2014 04/28/2010 Date Approved 02/19/2016 12/03/2018 12/09/2014 06/11/2014 06/15/2010 Adopt Date Required Date Adopted 07/01 /2014 Info in this Box from Pt —Contacts Date Date Date PT Pro Attended Attended Attended Formal Name g.Prime Phonel ext Fax HWA Wksp IUP Wkso PAR Wkso Mr. Chris Bitterman Prim 252-235-7933 1 1 11 1/24/2001 1 1/23/2001 cbitterman@envirolinkinc.com Pretreatment Coordinator PO Box 670 127807 Mr. Matt Settlemyer 1 11(336) 753-6701 msettlemyer@mocksvillenc.gov Town Manager 171 S. Clement Street 27028 Pretreatment Related NOVs from DWQ 6/24/1993 Itmp, hwa, erp, iws 9/23/1993 late SAR 3/9/1994 NCP 94-01 9/29/1994 program inadequate, late SAR 10/7/1996 late SAR 3/29/2001 IUPs, comp judge/enforce, pub not; 9/00 PCI 9/21/2001 enforce, imple stmp (from respon to 3/29 nov) 3/5/2003 failure to issue IUPs 4/9/2010 NOV-NOI for failure to submit PAR 2009 4/19/2010 NOV-NOI For PT elements (HWA, ERP, STM DWR Central Office Contact Imonti Hassan DWR Regional Contact jPaul DiMatteo SIU Facility Narrative for Town of Mocksville, NC The Town of Mocksville's only Significant Industrial User, Brakebush Brothers, was under construction for the entire 2019 calendar year. Due to this construction, there was no production at this facility and therefore no wastewater was discharged to the POTW. Chapter 9, PAR Guidance Pretreatment Performance Summary (PPS) 1. Pretreatment Town Name: Town of Mocksville 2. "Primary" NPDES Number NCO021491 or Non -Discharge Permit # if applicable => 3. PAR begin Date, please enter 01/01/yy 3. => 1/1/2019 4. PAR end Date, please enter 12/31/yy 4. => 12/31/2019 5. Total number of SIUs, includes CIUs 5. => 1 6. Number of CIUs 6. => 0 7. Number of SIUs with no IUP, or with an expired IUP 7. => 0 8. Number of SIUs not inspected by POTW 8. => 1 9. Number of SIUs not sampled by POTW 9. => I* 10. Number of SIUs in SNC due to IUP Limit violations 10. => 0 11. Number of SIUs in SNC due to Reporting violations 11. => 0 12. Number of SIUs in SNC due to violation of a compliance schedule, CO, AO or similar 12. => 0 13. Number of CIUs in SNC 13. => 0 14. Number of SIUs included in public notice 14. => 0 15 Total number of SIUs on a compliance schedule, CO, AO or similar 15. => 0 16. Number of NOVs, NNCs or similar assesed to SIUs 16. => 0 17. Number of Civil Penalties assessed to SIUs 17. => 0 18. Number of Criminal Penalties assessed to SIUs 18. => 0 19. Total Amount of Civil Penalties Collected 19. => $ 0 20. Number of IUs from which penalties collected 20. => 0 Votes: AO Administrative Order IUP Industrial User Pretreatment Permit POTW CIU Categorical Industrial User NNC Notice of Non -Compliance SIU Publicly Owned Treatment Works Significant Industrial User CO Consent Order NOV Notice of Violation SNC Significant Non -Compliance IU Industrial User PAR Pretreatment Annual Report The House of Raeford facility burned down 12/ 14/ 2017; therefore there was no facility to inspect and no process discharge to sample. revised 1/2018: PAR PPS 2018 Pretreatment Annual Report (PAR) WWTP = Wastewater Treatment Plant, use separate form for each WWTP. SIU = Significant Industrial User SNC = Significant Non -Compliance PAR covers this calendar year => Control Authority--Program--Town Name => WWTP Name => NPDES # _> A SNCR Form must be submitted with every PAR, please write "None " if you had No SIUs in SNC during calendar year IUP # Pipe # Industry Name Parameter or "Reporting" SNC? ( Yes / No) for each 6-month period. Jan. - June July - Dec. None Attach a copy of the Division's "SIUs in SNC Historical Report" for your POTW's SIUs behind this page. Is the database correct ? Notify the Division of any errors ! Database indicates SNC history for previous years. EVERY SNC MUST be explained in the Narrative, How was, is, or will it be resolved? REPEAT SNCs are serious matters that MUST be explained in the Narrative. Form name: PAR,SNCR,2001 Date Revised: 1/4/2001 2019 Mocksville Dutchman Creek NCO021491