HomeMy WebLinkAboutWQ0013361_Compliance Evaluation Inspection_20200318ROY COOPER
Governor
MICHAEL S. REGAN
Secretary
S. DANIEL SMITH
Director
Mr. and Mrs. Osvaldo Franco
2728 Weaver Hill Drive
Apex, NC 27502
Dear Mr. and Mrs. Osvaldo Franco,
NORTH CAROLINA
Environmental Quality
March 18, 2020
Subject: Permit No. WQ0013361
2728 Weaver Hill Drive SFR
Surface Irrigation Wastewater Treatment
and Disposal System
Wake County
On February 20, 2020 staff of the NC Division of Water Resources (DWR), Water Quality
Regional Operations Section (WQROS), inspected the subject single-family residence surface
irrigation wastewater treatment and disposal system. The purpose of the visit was to complete a
compliance inspection. I would like to thank Mr. Osvaldo for his assistance.
On the day of the inspection all single family residence wastewater treatment and application
equipment appeared to be well maintained. The septic tank is pumped on a 3-5 year schedule and
due within the next year. A pipe has been installed from the driveway to within 10 foot of the tank
to assist with the pumping due to the location of the tanks. The system was operated by hand and
appeared to be operating properly. The spray field was in good condition all heads were operating
as designed and vegetation was established. The dead and dyeing trees will be a consistent
maintenance issue but please try to keep the fallen trees removed. Please try to maintain the
larger/healthier trees.
If you have any questions, please contact me at (919) 791-4200 orjane.bemard@ncdeur.gov.
Attachments: Inspection Reports
Sincerely,
qa)�
Jane R. Bernard
Environmental Specialist, Division of
Water Resources, Water Quality
Regional Operations Section
D E Q North Carolina Department of Environmental Quality I Division of Water Resources
Raleigh Regional Office 1 3800 Barrett Drive I Raleigh, North Carolina 27609
Compliance Ins ection Report
Permit: W00013361 Effective: 04/13/09 Expiration: 03/31/18 Owner: Osvaldo Franco
SOC: Effective: Expiration: Facility: 2728 Weaver Hill Dr. SFR
County: Wake 2728 Weaver Hill Dr
Region: Raleigh
Apex NC 27502
Contact Person: Osvaldo Franco Title: Phone: 919-297-3293
Directions to Facility:
Take US 1 S to exit 89 N towards New Hill turn right onto New Hill/Holleman Road (turns into New Hill - Olive Chapel Road) turn
left onto Weaver Crossing (after Barker Road on left) turn left onto Weaver Hill Drive House is on the right.
System Classifications:
Primary ORC: Certification: Phone:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 02/20/2020 Entry Time 12:30PM Exit Time: 01:30PM
Primary Inspector: Jane Berrjrd Phone: 919-7914200
Secondary Inspector(s):
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Single -Family Residence Wastewater Irrigation
Facility Status: ■ Compliant Not Compliant
Question Areas.
Miscellaneous Questions 0 Permit Status Septic Tank
Sand Filter/Treatment Pods N Disinfection Tablets Pump Tank
Drip or Irrigation
(See attachment summary)
Page 1 of 4
Permit. W00013361 Owner -Facility: Osvaldo Franco
Inspection Date: 0212012020 Inspection Type: Compliance Evaluation Reason for visit: Routine
Inspection Summary:
On the day of the inspection all single family residence wastewater treatment and application equipment appeared to be well
maintained. The septic tank is pumped on a 3-5 year schedule and due within the next year. A pipe has been installed from
the driveway to within 10 foot of the tank to assist with the pumping due to the location of the tanks. The system was
operated by hand and appeared to be operating properly. The spray field was in good condition all heads were operating as
designed and vegetation was established. The dead and dyeing trees will be a consistent maintenance issue but please try
to keep the fallen trees removed. Please try to maintain the larger/healthier trees.
Page 2 of 4
Permit: WQ0013361 Owner - Facility: Osvaldo Franco
Inspection Date: 02/20/2020 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Permit Status
Yes No NA NE
# Is the current resident in the home the Permittee?
# If not, does the resident rent from the Permittee? ❑ El ❑
Change of Ownership form needed? (Mail the form with the inspection letter) ❑
El El El
# Is there an inspection and maintenance agreement with a contractor? ❑ ❑
If YES, who is the contractor (include contact info)?
Comment:
Septic Tank
Yes No NA NE
The septic tank and filters should be checked annually and pumped/cleaned as needed,
Is all wastewater from the home connected to the septic tank? ❑ ❑
# Does the permittee/resident know where the septic tank is located? ❑ 0 ❑
Has the septic tank been pumped in the last 5 years? ❑
El
If YES, describe if known and proof (include date pumped):
# Does the septic tank have an EFFLUENT FILTER or SANITARY T?
If FILTER, when was the filter cleaned and by who?
Comment:
Sand Filter/Treatment Pods
YsNo�NANE-
'"* Accessible sand filter surfaces shall be raked/leveled every 6 months and vegetative growth shall be
removed manually. '--
# Is system something other than a sand filler?
# If YES, what kind? (examples - Peat, Textile or brand name - Advantex, etc.)
# Does the permittee know where the sandfiller is located? El D El 0
Does the sandfiller require maintenance?
If maintenace is required, explain:
Comment:
Disinfection Tablets
Yes No NA NE
Tablet chlorinator unit shall be checked weekly to ensure continuous and proper operation.
Does the permittee Have the correct chlorine tablets? (It none, mark No) El ❑
El 0
# Does the Permittee know the location of the chlorinator? 1:1❑
11
Were chlorine tablets observed in the chlorinator?
Are tablets contacting water? (If possible, poke them to determine.)
Comment:
Pump Tank
Yes No NA NE
All pump and alarm sytems shall be inspected monthly. (Non -Discharge) ••`
Page 3 of 4
Permit: W00013361 Owner -Facility: Osvaldo Franco
Inspection hate: 02/20/2020 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Is the pump working?
Is the audible and visual high water alarm operational?
# Does the permittee know haw to check the pump & high water alarm?
# Last functional test:
Comment:
Drip or Irrigation
."" Irrigation sysetm shall be inspected monthly to ensure system is free of leaks and equipment is operating
as designed. "•
# Type of system (DRIP or IRRIGATION):
# If IRRIGATION, number of sprinkler heads:
Are buffers and setbacks adequate?
Is the site free of ponding and runoff?
Does the application equipment appear to be working properly?
Is there a minimum two wire fence surrounding the entire irrigation area?
Comment:
Yes No NA NE