Loading...
HomeMy WebLinkAbout20200331 Ver 1_More Info Requested_20200317Strickland, Bev From: Johnson, Alan Sent: Thursday, March 12, 2020 12:59 PM To: Michael Brame Cc: Perez, Douglas J Subject: RE: [External] SAW 2020-00205 - Pilot Project 5515_Summit Springs_2.25.2020PCN Application As you are aware, we request double culverts being installed with a base flow culvert and then a slightly elevated storm surge culvert (Mickey Mouse design). The application didn't include the culvert details. It was more of a diagram. Please provide the profile with culvert criteria/dimension/size Thanks From: Michael Brame [mailto:mbrame@pilotenviro.com] Sent: Thursday, March 12, 2020 10:00 AM To: Johnson, Alan <alan.johnson@ncdenr.gov> Subject: RE: [External] SAW 2020-00205 - Pilot Project 5515_Summit Springs_2.25.2020PCN Application External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to �imm@nc.gov Good Morning Alan, From the Civil — "The culvert crossing is double barrel 36" RCP's with a concrete headwall. There is 18 acres, with a flow of 56 CFS, that runs through this crossing. The velocity is over 7 FPS which requires outlet protection. " Please let me know if you need anything else. Sincerely, Michael T. Brame 336.708-4620 (c) 336.310.4527 (o) PO Box 128 Kernersville, NC 27285 www.pilotenvirc .com ilc mbrame@pilotenviro.com P I L Q T ENVI RON M E N T A L, I N C From: Johnson, Alan <alan.iohnson@ncdenr.gov> Sent: Wednesday, March 11, 2020 12:02 PM 1 To: Michael Brame <mbrame@pilotenviro.com> Subject: RE: [External] SAW 2020-00205 - Pilot Project 5515_Summit Springs_2.25.2020PCN Application What size/type culvert. Given the location of the culvert and drainage area upstream, is riprap really necessary From: Michael Brame [mailto:mbrame@pilotenviro.com] Sent: Tuesday, February 25, 2020 10:27 AM To: AshevilleNCREG@usace.army.mil; Johnson, Alan <alan.iohnson@ncdenr.gov>; Janiczak, Catherine M CIV USARMY CESAW (US) <Catherine.M.Janiczak@usace.army.mil> Cc: David Brame <dbrame@pilotenviro.com>; Heather LaGamba <hlagamba@pilotenviro.com> Subject: [External] SAW 2020-00205 - Pilot Project 5515_Summit Springs_2.25.2020PCN Application • External email. Do not click links or open attachments unless you verify. Send all suspicious email as an attachment to am @ nc. g ov Please find attached a PCN application for a site that we are working on in Rowan County that is attached. The site was previously verified by the USACE (SAW 2020-00205). The hard copy is being sent in with payment to the NCDEQ- DWR. Please let us know if there are questions or concerns that we need to address in order to get the PCN processed. Thank -you. Sincerely, Michael T. Brame 336.708-4620 (c) V`\, 336.310.4527 (o) ' PO Box 1284.,. Kernersville, NC 27285 PIL93 www.pilotenviro.com ilotenviro.co PILOT ENVI RON M E N T A L I N[ mbrame@pilotenviro.com N