HomeMy WebLinkAboutSW3190704_Revised Supplemental EZ Page_3/12/2020SUPPLEMENT-EZ COVER PAGE
FORMS LOADED
PROJECT INFORMATION
1
Project Name
Skyland Drive Townhomes
2
Project Area ac
4.335 acres
3
Coastal Wetland Area ac
0
4
Surface Water Area ac
0.171
5
Is this roject High or Low Density?
High
6
Does this project use an off -site SCM?
No
COMPLIANCE WITH 02H .1003(4)
7
Width of vegetated setbacks provided feet
30
8
Will the vegetated setback remain vegetated?
Yes
9
Is BUA other that as listed in .1 0034 c-d out of the setback?
Yes
10
Is streambank stabilization proposed on this project?
No
NUMBER AND TYPE OF SCMs:
11
Infiltration System
0
12
Bioretention Cell
0
13
Wet Pond
0
14
Stormwater Wetland
0
15
Permeable Pavement
0
16
1 Sand Filter
1
17
Rainwater Harvesting RWH
0
18
Green Roof
0
19
Level Spreader -Filter Strip LS-FS
0
20
Disconnected Impervious Surface (DIS)
0
21
Treatment Swale
0
22 1
Dry Pond
0
23
StormFilter
0
24
Silva Cell
0
25
Bayfilter
0
26
Filterra
0
FORMS LOADED
DESIGNER CERTIFICATION
27
Name and Title:
Barry M. Fay P.E.
28
Organization:
American Engineering Associates - Southeast P.A.
29
Street address:
8008 Corporate Center Drive, Suite 110
30
City, State, Zip:
Charlotte, NC 28226
31
Phone numbers :
704 375-2438
32
Email:
bfay@american-ea.com
Certification Statement:
I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or
supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and
that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent
with the information provided here.
Designer
C
E<- L
�✓,� • • �.�rnIN��4� •• q91
{vt ,'r[�ii♦
Signature of Designer
Date
DRAINAGE AREAS
1
Is this a high densityproject?
Yes
2
If so, number of drainage areas/SCMs
1
3
Is all/part of this project subject to previous rule
versions?
No
FORMS LOADED
DRAINAGE AREA INFORMATION
Entire Site
1
4
Type of SCM
Sand Filter
5
Total BUA in project (sq ft
58050 sf
61571 sf
6
New BUA on subdivided lots (subject to permitting)
(sq ft
27200 sf
27200 sf
7permitting)
New BUA outside of subdivided lots (subject to
s
30850 sf
30850 sf
8
Offsite - total area (sq ft
—
—
9
Offsite BUA (sq ft
3521 sf
10
Breakdown of new BUA outside subdivided lots:
- Parking (sq ft
864 sf
864 sf
- Sidewalk (sq ft
4573 sf
4573 sf
- Roof (sq ft
—
-
- Roadway s ft
20425 sf
20425 sf
- Future (sq ft
4988 sf
4988 sf
- Other, please specify in the comment box
below (sq ft
11
New infiltrating permeable pavement on
subdivided lots (sq ft
12
New infiltrating permeable pavement outside of
subdivided lots (sq ft
13permitting)
Exisitng BUA that will remain (not subject to
s ft
14
Existing BUA that is already permitted (sq ft
15
Existing BUA that will be removed (sq ft
16
Percent BUA
31 %
63%
17
Design storm inches
1 in
18
Design volume of SCM cu ft
3614 cf
19
Calculation method for design volume
Simple
JADDITIONAL INFORMATION
20
Please use this space to provide any additional information about the
drainage area(s):
Offsite BUA consists of existing pavement on Skyland Drive contributing to
onsite drainage areas. Future BUA area is for additional parking.
DRAINAGE AREA INFORMATION
Entire Site
1
4
Type of SCM
N/A
5
Total BUA from project (sq ft)
6
1995 rules
SL 2006-246
2008 rules
2017 rules
7
New BUA on subdivided lots (subject to
permitting) (sq ft)
1995 rules
SL 2006-246
2008 rules
2017 rules
8
New BUA outside of subdivided lots (subject to
permitting) (sf)
1995 rules
SL 2006-246
2008 rules
2017 rules
9
Offsite - total area (sq ft)
1995 rules
SL 2006-246
2008 rules
2017 rules
10
Offsite BUA (sq ft)
1995 rules
SL 2006-246
2008 rules
2017 rules
11
Design storm (inches)
_
1995 rules
SL 2006-246
2008 rules
2017 rules
12
Breakdown of new BUA:
- Parking (sq ft
- Sidewalk (sq ft
- Roof (sq ft
- Roadway s ft
- Future (sq ft
- Other, please specify in the comment box
below (sq ft
13
New infiltrating permeable pavement on
subdivided lots (sq ft
14
New infiltrating permeable pavement outside of
subdivided lots (sq ft
15permitting)
Exisitng BUA that will remain (not subject to
s ft
16
Existing BUA that is already permitted (sq ft
17
Existing BUA that will be removed (sq ft
18
Percent BUA
11 19
Design volume of SCM cu ft
20
Calculation method for design volume
ADDITIONAL INFORMATION
21
Please use this space to provide any additional
information about the drainage area(s):
SAND FILTER
1 IDrainage area number 1 I
3
Is the SCM sized to treat the SW from all surfaces at build -out?
Yes
4
Is the SCM located away from contaminated soils?
Yes
5
What are the side slopes of the SCM (H:V)?
3:1
6
Does the SCM have retaining walls, gabion walls or other engineered
side slopes?
Yes
7
Are the inlets, outlets, and receiving stream protected from erosion (10-
year storm)?
Yes
8
Is there an overflow or bypass for inflow volume in excess of the design
volume?
Yes
9
What is the method for dewatering the SCM for maintenance?
Other
10
If applicable, will the SCM be cleaned out after construction?
Yes
11
Does the maintenance access comply with General MDC (8)?
Yes
12
Does the drainage easement comply with General MDC (9)?
Yes
13
If the SCM is on a single family lot, does (will?) the plat comply with
General MDC (10)?
14
Is there an O&M Agreement that complies with General MDC (11)?
Yes
15 1
Is there an O&M Plan that complies with General MDC (12)?
Yes
16 1
Does the SCM follow the device specific MDC?
Yes
17 1
Was the SCM designed by an NC licensed Drofessional?
Yr s
18 1 SHWT elevation (fmsl) See Report
19 Type of and filter (open or closed) Open
20 If closed, will the filter will be pre -cast or pour -in -place?
21 If closed, top of grate elevation (fmsl)
22 Is this sand filter designed to attenuate peak flows? Yes
.Sediment Chamher
23
Volume that can be retained in the sediment chamber (cubic feet)
1982 cf
24
Will there be a permanent pool in the sediment chamber?
No
25
Bottom of the sediment chamber (fmsl)
666.00
26
Area of the sediment chamber (square feet)
844 sf
27
Physical depth of the sediment chamber (inches)
20.4
Ponding depth in the sediment chamber, above any permanent pool
(inches)
L228
9 1
Elevation of top of weir between chambers (fmsl)
668
I Sand Chamher
30
Volume that can be retained in the sand chamber (cubic feet)
1974 cf
31
Bottom of the sand chamber (fmsl)
666.00
32
Area of the sand chamber (square feet)
845 sf
33
Physical depth of the sand chamber (inches)
20.4
34
Ponding depth in the sand chamber, above any permanent pool
(inches)
35
Elevation of the bypass device (fmsl)
667.7
36
Type of bypass device
Orifice/Bleeder
37
Mechanism for distributing flow over the sand surface
Sheet Flow
38
Sand specification for sand chamber
ASTM C33
39
Depth above underdrain pipe (inches)
30 in
40
Will the media be maintained to drain at least two inches per hour at the
sand surface?
Yes
41
Is at least one clean -out pipe provided at the low point of each
underdrain line?
Yes
42 1
Will clean -out pipes be capped?
Yes
TONAL INFORMATION
Please use this space to provide any additional information about the
Sand Filter(s):
All of the runoff from proposed BUA is directed towards the sand filter
Dewatering will consist of a pump and a silt bag.
Sand Filter 1 4:58 PM 3/11/2020