Loading...
HomeMy WebLinkAboutWQ0041392_Application (FTSE)_20200107®EQIDWR State of North Carolina JAN 0 6 2020 Department of Environmental Quality DWK Division of Water Resources 15Ah Reg .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of water ResouFANETTEVILLEREGIONALOFFICE FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: W Q 0041.31 % (to be m,npleted by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Harnett Regional Water (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other 3. Signature authority's name: Steve Ward per 15A NCAC 02T 0106fb1 Title; Director 4. Applicant's mailing address: 700 McKinney Parkway City: Lillineton State: NC Zip: 27546-_ 5. Applicant's contact information: Phone number: 210 893-7575 Email Address: sward @Iiarnett.ore II. PROJECT INFORMATION: 1. Project names Quail Glen- Phase 5 ; 2. Application/Project status: ['Z Proposed (New Permit); ❑ Existing Permit/Project If a modification, provide die existing permit number: W000_ and issued date: _ If new construction but part of a master plan, provide the existing permit number: W000_ 3. County where project is located: Harnett 4. Approximate Coordinates (Decimal Degrees): Latitude: 35_28' Longitude:-78_48' 5. Parcel ID (if applicable): 0652-93-2092.000 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Peter E. Norfleet. Temple License Number: 024441 Firm: Enoch Engineers, PA Mailing address: 1403 NC 50 S City: Benson State: NC Zip: 27504-_ Phone number: 919) 894-1765 Email Address: fleet enochengineers com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: Facility Name: North Harnett Regional W WTP Permit Number NCO021636 Owner Name: Harnett Regional Water V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): 1. Permit Number(s): WQ0041168 System Wide Collection System Permit Number(s) (if applicable): WQCS000166 Owner Name(s): Harnett Regional Water FORM: FTA 04-16 Page 1 of 5 VI. 'GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? [:]Yes []No NNIA 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DEV) been attached? ❑ Yes ❑No NN/A 3. If the Applicant is a Home/Property Owners' Association has an Operational Agreement (FORM: HOA) been attached'? ❑ Yes ❑No ON,/A 4. Origin of wastewater: (check all that apply) M Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100% Domestic/Commercial _% Commercial _ % Industrial (See 15A NCAC 02T 0103(20)) L----*Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(fl? ❑ Yes ® No D If yes provide a copy of flow reduction approval letter Summarize wastewater generated by project: Establishment Type (see 02'P.0114(fl) Dailv Design Flow n'b No. of Units Flow Residential Lots 360 gal/dayflot 41 14,760 GPD, gal/ GPD gal/ GPD gall GPD gal/ GPD gal/ GPD Total 14,760 GPD a See 15A NCAC 02T 0114(b) (d) (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.0114] shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 14760 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If pennitted flow is zero, indicate why; ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Pennit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VIL GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize eravity sewer to be permitted: Size (inches) Length (feet) Material 8 2,442 PVCSDR35 g 185 PVC C-900 Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is notallowed and a violation of the MDC VIll. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Puma Stations/Force Mainsl: COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT I. Pump station number or name: 2. Approximate Coordinates (Decimal Degrees): Latitude: Longitude: - ° 3. Design flow of the pump station: _ millions gallons per day (firm. capacity) 4. Operational point(s) of the pump(s): _ gallons per minute at_ feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): r hes) Length (feet) Material 6. Power reliability in accordance with 15A NCAC 02T 0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(13): ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. Page 3 of 5 FORM: FTA 04-16 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 0210305(fl & N �m _ .°rims tn,nt c1,.111,P nmvided fnr Sewersystems: N Yes El No / 1JH lYliHl:.. vL y __ ___ __ Setback Parameter* Separation Required Storm sewers and other utilities not listed below (vertical) 24 inches Water mains (vertical -water over sewer including in benched trenches) 18 inches Water mains (horizontal) 10 feet Reclaimed water lines (vertical - reclaimed over sewer) 18 inches Reclaimed water lines (horizontal - reclaimed over sewer) 2 feet **Any private or public water supply source, including any wells, WS-1 waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet **Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation) and wetlands (see item IX.2) 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade (vertical) 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(f) cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications weboage ➢ If noncompliance with 02T 0305(f) or (g). see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) N. Yes ❑ No ➢ Seethe Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with all setbacks found in the river basin rules per 15A NCAC 02B .02009 N Yes [:]No ➢ This would include Trout Buffered Streams per 15A NCAC 213.0202 4. Does the project comply with an individual 404 Permit or any 401 Certifications? N Yes ❑ No ➢ Wetland -related permits shall be requested, obtained, and adhered to for projects that impact wetlands or surface waters ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? N Yes ❑ No Per 15A NCAC 02T 0105(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stonnwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "higii-priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undennines or deteriorates the sewer. [:]Yes N No ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 X. CERTIFICATIONS: Does the submitted system comply with 15A NCAC 02T, the Minimu and Force Mains (latest version), and the. Gravity Sewer Minimum Des Z Yes ❑ No as applicable? If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Approval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Professional Engineer's Certification: name from Application Item III.1.) application for eaw-6.. Gt,%6V-z - has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and. 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000, as well as civil penalties up to $25,000 per violation, North Carolina Professional Engineer's seal, signature, and date: 3. Applicant's Certification per 15A NCAC 02T .0I06(b): that this application for (Signature utliority's name & title from Application Item I.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 143-215.6A and 143-215.6B, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed $10,000 as well as civil penalties up to $25,000 per violation. i-9Signature: Date: Page 5 of 5 FORM: FTA 04-16 State of North Carolina Department of Environmental Quality Division of Water Resources Division of Water Resources Flow Tracking/Acceptance for Sewer Extension Applications (FTSE 04-16) Entity Requesting Allocation: Harnett Regional Water Project Name for which flow is being requested: Quail Glenn Phase 5 — 41 Res. Lots More than one FTSE may be required for a single project if the owner of the WWTP is not responsible for all pump stations along the route ofthe proposed wastewater flow. I. Complete this section only if you are the owner of the wastewater treatment plant. a. WWTP Facility Name: North Harnett Regional WWTP b. WWTP Facility Permit #: NC0021636 All flows are in MGD c. WWTP facility's permitted flow 7.5 MGD Fuquay-Varina Allocated Flow 2.60 MGD Lillington Allocated Flow 1.20 MGD Angier Allocated Flow 1.008 MGD d. Estimated obligated flow not yet tributary to the WWTP 1.179 MGD FV Obligated Flow NYT 0.597 MGD Lillington Obligated Flow NYT 0.113 MGD HC Obligated Flow NYT 0.324 MGD Angier Obligated Flow NYT 0.145 MGD e. WWTP facility's actual avg. flow 4.867 MGD FV Actual Flow 1.369 MGD Lillington Actual Flow 0.770 MGD HC Actual Flow 2.097 MGD Angier Actual Flow 0.631 MGD f. Total flow for this specific request 0.015 MGD g. Total actual and obligated flows to the facility 6.061 MGD FV Actual Avg. + Obligated Flow 1.966 MGD Lillington Actual Avg. + Obligated Flow 0.883 MGD HC Actual Avg. + Obligated Flow 2.436 MGD Angier Actual + Obligated Flow 0.776 MGD h. Percent of permitted flow used 80.81 % Page I of 4 FTSE 06-11 II. Complete this section for each pump station you are responsible for along the route of this proposed wastewater flow. List pump stations located between the project connection point and the W WTP: (A) Design Pump Average Daily Station Firm Flow** (Name or Capacity, * (Firm / pf), Number) MGD MGD (B) (C) (D)=(B+C) (E)=(A-D) Obligated, Approx. Not Yet Total Current Current Avg. Tributary Flow Plus Daily Flow, Daily Flow, Obligated Available MGD MGD Flow Capacity*** SLS 120 14.4 5.76 2.755 1.016 3.7771 1.989 * The Firm Capacity of any pump station is defined as the maximum pumped flow that can be achieved with the largest pump taken out of service. ** Design Average Daily Flow is the firm capacity of the pump station divided by a peaking factor (pf) not less than 2.5. *** A Planning Assessment Addendum shall be attached for each pump station located between the project connection point and the W WTP where the Available Capacity is < 0. Downstream Facility Name (Sewer): North Harnett Regional W WTP Downstream Permit Number: NC0021636 III. Certification Statement: I Steve Ward certify to the best of my knowledge that the addition of the volume of wastewater to be permitted in this project has been evaluated along the route to the receiving wastewater treatment facility and that the flow from this project is not anticipated to cause any capacity related sanitary sewer overflows or overburden any downstream pump station en route to the receiving treatment plant under normal circumstances, given the implementation of the planned improvements identified in the planning assessment where applicable. This analysis has been performed in accordance with local established policies and procedures using the best available data. This certification applies to those items listed above in Sections I and II plus all attached planning assessment ad ums for which I am the responsible party. Signature of this form indicates acceptance of thi Vfastewater flow. Signing Vate Page 2 of 4 FTSE 06-13 I Enoch DEQIDWR nglneers,P.A. 31 Joe E. Godwin Sr., P.E., P.L.S. Consulting Engineers & Surveyors JAN 0 6 2020 Phone: (919) 894- (919)894-7776565 Email: general@enocheogineeis.com 1403 N.C. 50 South 1A 1QR®c Fax: (919) 894-8190 Benson, NC 27504 1` 1�ET7EUlUFPPPIONALOFFICE December 9, 2019 NC DENR-Division of Water Quality 225 Green Street, Suite 714 Fayetteville, NC 28301-5094 Re: Quail Glen - Phase 5 Trent: Enclosed: One original & one copy of Fast Track Application (FTA 04-16) Application Fee ($480.00) Form FTSE USGS Topographic Map Street level map Quail Glen - Phase 5 is an 41 lot single family residential development phase located off of SR 2215 (Harnett Central Rd.), Angier, Harnett County, North Carolina. The phase will be served by an existing gravity sewer outfall which is located along Neill's Creek along the western boundary of the property. The entire Quail Glen section will have a total of 159 lots at full build out, with flow for the 41 lots in Phase 5 being requested at this time. After receipt of this information, if you have any questions or discussion, please call. Respectfully, Fleet Temple Enoch Engineers, PA State of North Carolina Department of Environmental Quality DWR Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the apnlication will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Harnett Regional Water (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ❑ Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ® Municipal ❑ Other RCGLBvtpu 3. Signature authority's name: Steve Ward per 15A NCAC 02T .0106(b) DLQI D U!! re Title: Director 4. Applicant's mailing address: 700 McKinney Parkway City: Lillinaton State: NC Zip: 27546 5. Applicant's contact information: Phone number: 910 593-7575 Email Address: swardAbamett.org U. PROJECT INFORMATION: JAN 0 6 2020 `�AYMEVILLE F �®O dAl OFFICE / / eWPV1 I. Project name: Quail GIen -Phase 5 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W000_ and issued date: _ If new construction but part of a master plan, provide the existing permit number: W000_ 3. County where project is located: Harnett j 4. Approximate Coordinates (Decimal Degrees): Latitude: 35_28' Longitude:-78_480 5. Parcel ID (if applicable): 0652-93.2022.000 (or Parcel ID to closest downstream sewer) Rt:ur-ivr-u ®EQIDWR JAN 06 2020 F'AYETfEVILLEQRORFGIONALOFFICE amR Permit Number WQ0041392 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer trent.allen Coastal SWRule Permitted Flow 14,760 Facility Central Files: APS _ SWP 1/27/2020 Permit Tracking Slip Status Project Type Active. New Project Version Permit Classification 1.00 Individual Permit Contact Affiliation Facility Name Major/Minor Region Quail Glen - Phase 5 Minor Fayetteville Location Address County Harnett Facility Contact Affiliation Owner Owner Name Owner Type Harnett Regional Water Non -Government Owner Affiliation Steve Ward Director Interim Public Utilities of PG Box 1119 Dates/Events Lillington NC 27546111 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 1/27/2020 1/6/2020 1/27/2020 1/27/2020 Regulated Activities Requested /Received Events Wastewater collection Additional information requested Additional information received Outfall Waterbody Name Streamindex Number Current Class Subbasm