Loading...
HomeMy WebLinkAboutNC0020338_AUTHORIZATION TO CONSTRUCT_19890208 ✓�4 State of North Carolina Department of Natural Resources and Community Development Division of Environmental Management 512 North Salisbury Street 0 Raleigh, North Carolina 27611 James G. Martin, Governor R. Paul Wilms William W. Cobey, Jr., Secretary February 8, 1989 Director Mr. Jerry Carlton Town of Yadkinville P.D. Drawer 816 Yadkinville, N.C. 27055-0816 SUBJECT: Permit No. NCO020338 Authorization to Construct Town of Yadkinville Yadkinville Wastewater Treatment Plant Yadkin County Dear Mr. Carlton: A letter of request for an Authorization to Construct was received November 23, 1988, by the Division and final plans and specifications for the subject project • have been reviewed and found to be satisfactory. Authorization is hereby granted for the construction of additional facilities to upgrade the existing treatment facility to accomodate one million gallons per day consisting of modification of the existing treatment plant into a aerobic sludge digestor, a 1150 GPM influent pump station with triplex pumps, a 1.27 .million gallon aeration basin, three 1,400 scfm blowers for aeration, a new 113,000 gallon circular clairfier, three parshall flumes for sludge measurement, a digestor decanting pump station with dual 300 GPM pumps with return of decanted wastewater back to the equalization basin, a additional chlorine contact chamber bringing the total contact chamber volume to 26,670 gallons and two groundwater monitoring wells with discharge of treated wastewater to Haw Branch. This Authorization to Construct is issued in accordance with Part III paragraph B of the NPDES Permit No. NCO020338 issued December 10, 1987, and shall be subject to revocation unless the wastewater treatment facilities are constructed in accordance with the conditions and limitations specified in Permit No. NC0020338. The Permittee must employ a certified wastewater operator in accordance with Part III paragraph C of the referenced permit. The sludge generated from these treatment facilities must be disposed of in accordance with G. S. 143-215. 1 and in a manner approvable by the North Carolina Division of Environmental Management. The Winston-Salem Regional Office, telephone number '919/761-2351 shall be notified at least twenty-four (24) hours in advance of operation of these . facilities. Such notification to the Regional Supervisor shall be made during the normal office hour from 8:00 a.m. until 5:00 p.m. on Monday through Friday, excluding State Holidays. P.O. Box 27687, Raleigh, North Carolina 27611-7687 Telephone 919-733-7015 An Equal Opportunity Affirmative Action Employer In event the facilities fail to perform satisfactorily in meeting its NPDES permit effluent limits, the permittee shall take such immediate corrective action as may be required by this Division, including the construction of additional wastewater treatment and disposal facilities. Upon completion of construction and prior. to operation of this permitted facility, a certification must be received from a professional engineer certifying that the permitted facility has been installed .in accordance with the approved plans and specifications. Mail the Certification to the Permits and Engineering Unit, P.O. Box 27687, Raleigh, N.C. 27611-7687. A set of approved plans and specifications for the subject project must be retained by the applicant for the life of the project. The Town of Xadkinville shall submit an application for land application of municipal sludge to the Division of Environmental Managment on or before August 1, 1989. No sludge shall be returned to the equalization basin from the sludge decant pump station. Within 90 days of permit issuance, two (2) monitor wells, one (1) upgradient and one (1) downgr.adi.ent, shall. be installed to monitor groundwater quality. The l-ocAtion and construction details for these wells shall be approved by the Winston-Salem Regional. Office, from which a well construction permit must be • obtained. The monitor wells must be sampled initially after construction and thereafter every March, July, and November for the following parameters: NO3 Ammonia Nitrogen TDS Total Coliforms TOC PH Chloride TOX (in November only) The mnasur.nment of water level must be made prior to sampling for the remaining parameters. If TOC concentrations greater than 3.0 mg/l are detected in any downgradient monitoring wel.l., additional sampling and analysis must be conducted to identify the individual constituents comprising this TOC concentration. If the TOC concentration as measured in the background monitor well exceeds 10 mg/l, this concentration will be taken to represent the naturally occuring TOC concentration. Any exceedances of this natrrally occuring TOC concentration in the downgradient wells shall be subject to the additional sampling and analysis as described above. • The analytical methods used for TOX must be capable of detecting the total of all halogenated organic compounds present at a concentration of 5.0 parts per. billion (ppb) or. greater. In the event that a TOX concentration of 5.0 ppb or greater i.s detected, any individual halogenated organic compound(s) present at a concentration at or above the method detection limit (MD1,) must be identified and quantified utilizing EPA methods 601, 602, 604, and 611. The results of the sampling and analysis shall be sent to the N.C. Division of Environmental. Management on Form GW-59 (Compliance Monitoring Report Form) every April, August and December Any additional groundwater quality monitoring as deemed necessary 'by the Department, shall be provided. One (1) set of approved plans, and specifications is being forwarded to you. If you have any questions or need additional information, please contact Mr. Jack Floyd, telephone number 9.19/733-5083. Sincerely, R. Paul Wilms • cc Yadkin County Health Department Winston-Salem Regional Supervisor Groundwater Section Municipal. Engineering Mr. . John Campbell r Engineer' s Certification 1 as a duty registered Professional Engineer in the State of North Carolina, hereby certify that construction of these permitted facilities has been completed in accordance. with the approved plans and specifications. Signature Registration Nwnber Date NCO020338 •