Loading...
HomeMy WebLinkAbout20180307 Ver 2_CompleteFile_WQC_20180712State of North Carolina D_ Department of Environment and Natural Resources .wWR Division of Water Resources Dtvlslon of Water Resources 15A NCAC 02B .0233 (8)(b), .0243 (8)(b), .0250 (11)(b), .0259 (8)(b), .0267 (11)(c), .0607 (e)(2) Protection and Maintenance of Riparian Areas Rules - Variance Application FORM: VAR 10-2013 PLEASE IDENTIFY WHICH RIPARIAN AREA PROTECTION RULE APPLIES: ❑ Neuse River Basin (15A NCAC 02B.0233) Major Variance D Minor Variance ❑ Catawba River Basin (15A NCAC 02B.0243) ❑ Randleman Lake Water Supply Watershed (15A NCAC 02B.0250) Major Variance n Minor Variance ❑ Tar -Pamlico River Basin (15A NCAC 02B.0259) Major Variance c Minor Variance ❑ Jordan Lake Water Supply Nutrient Strategy (15A NCAC 02B.0267) Major Variance ; Minor Variance Goose Creek Watershed (15A NCAC 02B.0606 & 15A NCAC 02B.0607) A. General Information 1. Applicant's Information(if other than the current property owner): Name: Charlotte Water (Nicole Bartlett) Title: Project Manager Street Address: 5100 Brookshire Blvd. City, State & Zip: Charlotte, NC 2821 Telephone: 704-399-2221 Email: nbartlett@ci.charlotte.nc.us 2. Property Owner/Signing Official (person legally responsible for the property and its compliance): Name: Title: Street Address: City, State & Zip: Telephone: Email: FORM: VAR 10-2013 See above 3. Agent Information: 3a. Name: Company Affiliation Street Address: City, State & Zip: Telephone: E-mail: Jason Marshall GH 222 South Church Street Charlotte, NC 28202 704-342-4910 Jason.marshall@ghd.com 3b. Attach a signed and dated copy of the Agent Authorization letter if the Agent has signatory authority for the owner. 4. Project Name (Subdivision, facility, orestablishment name): Stevens Creek Trunk Sewer - Phase 1 5. Project Location: 5a. Street Address: See Attached Property Easement List City, State & Zip: Mint Hill, NC 5b. County: Mecklenburg 5c. Site Coordinates (in decimal degrees): 35.1436 Latitude 80.6483 Longitude 5d. Attach an 8 % x 11 excerpt from the most recent version of the USGS topographic map indicating the location of the site. 5e. Attach an 8 % x 11 excerpt from the most recent version of the published County NRCS Soil Survey Map depicting the project site. 6. Property Information: 6a. Property identification number (parcel ID): See Attached Property Easement List 6b. Date property was purchased: NA 6c. Deed book 6d. Map book and page number and page number 6e. Attach a copy of the recorded map that indicates when the lot was last platted. 7. Is your project in one of the 20 Coastal Counties covered under the Coastal Area Management Act (CAMA)? ❑ YES ❑ NO . 7a. If you answered yes above, in which AEC do you fall (30 ft or 75 ft)? NA 7b. If you answered yes above, what is the total percent of impervious cover that you have proposed within the AEC? NA FORM: VAR 10-2013 Page 2 of 7 8. Directions to site from nearest major intersection: Exit 1-485 at Lawyers Road towards Mint Hill, NC, Ge left on Thompson Road, continue on Thompson Road until you reach the confluence of a tributary to Stevens Creek and Stevens Creek. Project parallel creeks. 9. Stream associated with riparian buffer to be impacted by the proposed activity: Name Water Quality Classification Stevens Creek and Tributary to Stevens Creek C 9a. For Goose Creek only: Is the buffer in the 100 -year floodplain? ❑ YES ❑ NO 10. List any permits/approvals that have been requested or obtained for this project in the past (including all prior phases). Date Applied: Date Received 8/23/2017 9/21/2017 8/31/2017 9/25/2017 2/27/2017 9/12/2017 5/3/2017 8/1/2017 8/29/2017 B. Proposed Activity Permit Type: NCDOT Utility Encroachment NCDENR Erosion Control PCN Meck. Co. Floodplain Development Town of Mint Hill — Road Crossing Permit 1. Project Description 1a. Provide a detailed description of the proposed activity including its purpose: The Durpose of this oroiect is to provide sanitary sewer service to users currently serviced by a Dackaee WWTP and to Provide additional sanitary sewer service to the Stevens Creek Basin. This project is located along Stevens Creek and a Tributary to Stevens Creek west of 1-485. Service along the Stevens creek Tributary will ultimately allow for the removal Of existing pump stations and limit the use of septic systems. This project is being coordinated with a stream restoration project on Stevens Creek that shares the similar project limits. Charlotte Water is working with Mecklenburg County Stormwater to construct the sewer and stream restoration projects at the same time so that disturbance within the area will be done once and to limit the total area of clearing by best utilizing each projects required temporary construction 1b. Attach a site plan showing the following items as applicable to the project: 0 Development/Project name 0 Revision number & date 0 North arrow 0 Scale (1" = 50' is preferred) 0 Property/project boundary with dimensions 0 Adjacent streets and roads labeled with names and/or NC State Road numbers 0 Original contours and proposed contours 0 Perennial and intermittent streams, ponds, lakes, rivers and estuaries FORM: VAR 10-2013 Page 3 of 7 0 Mean high water line (if applicable) 0 Wetlands delineated, or a note on plans that none exist 0 Location of forest vegetation along the streams, ponds, lakes, rivers and estuaries 0 Extent of riparian buffers on the land including Zone 1 and Zone where applicable 0 Location and dimension of the proposed buffer impact (label the area of buffer impact in ft' on the plan) 0 Details of roads, parking areas, cul-de-sacs, sidewalks, and curb and gutter systems 0 Footprint of any proposed buildings or other structures 0 Discharge points of gutters on existing structures and proposed buildings 0 Existing drainage (including off-site), drainage easements, and pipe dimensions 0 Drainage areas delineated C. Proposed Impacts and Mitigation 1. Individually list the square footage of each proposed impact to the protected riparian buffers: Buffer Impact Goose Buffer Zone 1 Number'— Reason for Impact Buffer �_.._ _ ....�___ Zone 1 Impaet Zone 2 Imre. n+ �_.. Permanent (P) or (square feet) Mitigation Uzi 3 Temporary (T) Required (2 for Catawba only) 61 - ❑ P ® T Excavation — Temp ❑ Yes ❑ No 194,501 Total Buffer Mitigation Required: Easement B2 - ❑ P ® T Excavation- Permanent ❑ Yes ❑ No 128,567 Easement 63 -EP [:]T ❑ Yes ❑ No 121,546 Total Buffer Impacts 121,546 'Label on site plan 2. Identify the square feet of impact to each zone of the riparian buffer that requires mitigation from the table above. Calculate the amount of mitigation required. 'For projects in the Goose Creek Watershed, list all riparian buffer impacts as Zone 1 and use Zone 1 multiplier. 3. Provide a description of how mitigation will be achieved at your site pursuant to the mitigation requirements of the applicable river basin/watershed. See Attachment 3a. Is buffer restoration or enhancement proposed? ',K Yes ❑ No If yes, attach a detailed planting plan to include plant type, date of plantings, the date of the one-time fertilization in the protected riparian buffers, and a plan sheet showing the proposed location of the plantings. 3b. Is payment into a buffer restoration fund proposed? ❑ Yes `g[ No If yes, attach an acceptance letter from the mitigation bank you propose to use or the NC Ecosystem Enhancement Program stating they have the mitigation credits available for the mitigation requested. FORM: VAR 10-2013 Page 4 of 7 Required Zone Total Impact Multiplier Mitigation (square feet) (square feet) Zone 1' 121,546 3 364,638 (2 for Catawba only) Zone 2 1.5 Total Buffer Mitigation Required: 'For projects in the Goose Creek Watershed, list all riparian buffer impacts as Zone 1 and use Zone 1 multiplier. 3. Provide a description of how mitigation will be achieved at your site pursuant to the mitigation requirements of the applicable river basin/watershed. See Attachment 3a. Is buffer restoration or enhancement proposed? ',K Yes ❑ No If yes, attach a detailed planting plan to include plant type, date of plantings, the date of the one-time fertilization in the protected riparian buffers, and a plan sheet showing the proposed location of the plantings. 3b. Is payment into a buffer restoration fund proposed? ❑ Yes `g[ No If yes, attach an acceptance letter from the mitigation bank you propose to use or the NC Ecosystem Enhancement Program stating they have the mitigation credits available for the mitigation requested. FORM: VAR 10-2013 Page 4 of 7 D. Stormwater 1. Provide a description of how diffuse flow will be maintained through the protected riparian buffers (e.g., re -planting vegetation or enhancement of existing vegetation, gutter splash pads, level spreader to control of runoff from impervious surfaces, etc.). A diffuse flow plan has not been included as part of this project. The project involves temporary ground impacts with no change in topography. No impervious areas are being added as part of this project. la. Show the location of diffuse flow measure(s) on your site plan. NA 1b. Attach a completed Level Spreader Supplement Form or BMP Supplement Form with all required items for each proposed measure. NA 1c. Attach an Operation and Maintenance (O&M) Form for each proposed level spreader or BMP. NA 2. For Major, Catawba, and Goose Creek variance requests, provide a description of all best management practices (BMPs) that will be used to minimize disturbance and control the discharge of nutrients and sediments from stormwater. This project will utilize temporary erosion control devices through construction as approved by NCDENR erosion control permit. No permanent stormwater management practices are required for this project. No impervious areas are being added as part of this project. 2a. Show the location of BMPs on your site plan. NA 2b. Attach a Supplement Form for each structural BMP proposed. NA 2c. Attach an Operation and Maintenance (O&M) Form for each structural BMP proposed. NA E. Demonstration of Need for a Variance The variance provision of the riparian buffer rules allows the Division or the Environmental Management Commission to grant a variance when there are practical difficulties or unnecessary hardships that prevent compliance with the strict letter of riparian buffer protection. Explain how complying with the provisions of the applicable rule would prevent you from securing a reasonable return from or make reasonable use of your property. Merely proving that the variance would permit a greater profit from the property shall not be considered adequate justification for a variance. The Division will consider whether the variance is the minimum possible deviation from the terms of the applicable Buffer Rule that shall make reasonable use of the property possible. We are seeking a variance for a rule stated under 15A NCAC 02B .0607, Page 5, Non -electric utility lines with impacts other than perpendicular crossings, Stated as "Wastewater collection system utility lines and lift station lines may impact the riparian zone if both gravity and force main collections systems are made of ductile iron and 50% of the collection system is cleaned annually." We are requesting the requirement for ductile iron pipe be waved for in favor of PVC, AWWA C900, Pressure Class 165 psi, DR25 as an equal to ductile iron pipe. Ductile iron pipe will be used at stream crossing locations, within 50' of wetlands, and where pipe cover exceeds 20'. DIP will also extend 10' on either side of the crossing or to the first manhole. A total of 6 stream crossings are included a part of this variance request. Plans showing locations with material designations listed and specifications for sewer system have been included in this request. Also note that all pipe and manholes are subject to leakage testing to ensure the system is watertight. A specification for leakage testing has been included in with this application. The sewer line consists of 9,902' of sewer pipe with 2,910' of DIP and 6992' of PVC pipe. This project will utilize a 50' wide construction corridor with a 15' wide permanent maintenance corridor. We are also seeking a variance for rule stated under 15A NCAC 02B .0607, Page 6 Non -electric perpendicular utility line FORM: VAR 10-2013 Page 5 of 7 crossings that are collections systems as defined in Rule 15A NCAC 02T.0300 (note: must follow constraints listed under wastewater collection system utility lines and lift stations, above): Stated as "That use any of the following installation methods to minimize the sediment, nutrient and other pollution through the riparian buffer: underground directional boring methods, bore -and -jack techniques or another appropriate microtunnelling method." We are requesting the requirement for trenchless crossings of streams for this project be waved since the construction of the stream restoration and sanitary sewer will be completed as one project. The stream restoration work entails grading existing streambanks, relocation of existing stream bed at various locations, and rebuilding the stream bed that will increase the elevation of the existing channel. The requirement to provide trenchless installations on this project will create additional large excavations for boring and receiving pits required to install equipment used to make crossings. These large excavation must be maintained and dewatered to provide a safe working environments and could arguably be more disruptive based on the area required and additional time needed to make the installation. Standard cut and cover installations move much quicker and can therefore be stabilized sooner. With stream disturbances already implemented for restoration, the sewer installations have a minor overall impact. Additional excavation disturbance would be required to install launching and receiving pits. This requirement is intended to limit disturbances at stream crossings on typical projects that do not have a stream restoration component. We believe the considerable cost to include trenchless installation for methods that are intended to limit disturbance are not a good use of public funds. There are two main stream crossing locations on Stevens Creek and four intermittent/ephemeral crossings. Stevens Creek crossings are located at stations 26+00 and 28+00. The intermittent/ephemeral crossings are located at station 16+75, 45+00, 55+00, and 64+00. The relative location of the sewer and proposed stream crossings closely mirrors the existing channel to be reconstructed. At the proposed sewer crossing locations, the new stream is offset by approximatly10 to 20 feet from the existine location. 2. Explain how the hardship results from application of the Buffer Rule to the property rather from other factors such as deed restrictions or other hardships (e.g. zoning setbacks, floodplains, etc). We believe the circumstances under which the proiect is being completed are unique in character and that the combined effort to complete both the sewer and stream restoration as one project should be considered with regard to means used to construct the project. Consideration of rules requiring trenchless installations should be waved due to the overall stream disturbances required to construct the proiect. The stream bed and banks will be changed and grades adjusted and because of this open cut installations should be made. An open cut installation can be completed in a day or two. A trenchless installation can take weeks. This means a much longer exposure time to potential problems that include flooding of the pits require to make the installation. The ground disturbance for to bore and iack requires a 20' x 40' pit on the launching side and a 10' x 10' piton the receiving side versus 4' wide trench to open cut the crossing. Shallow bores under creeks tend to allow the creek to find it's way into the pits requiring the creek to be bypassed in the same manner that is required for open cut installations. This means the contractor will automatically perform a piped or pumped bypass around the crossing area. Time should be a maior consideration. If it takes a week or two to bore due to rock and tough drilling conditions then all that time would require additional dewatering to keep the pits dry. If the weather goes bad then the drilling equipment may need to be removed causing additional delays and possible construction issues that could end in having to drilling a hole. We consider these additional risk hardships that are not necessary based on how this project will be constructed. 3. Explain how the hardship results from physical nature of the property, such as its size, shape, or topography, which is different from that of neighboring property. The property upstream of the confluence of Stevens Creek and the tributary to Stevens Creek is challenging location due to the steeper slopes and hills. Moving uphill to the buffer line away from the creek to construct the sewer line creates a situation where the depth makes installation cost prohibitive due to shoring and rock removal required to make installation. The pipe centerline is currently 50 to 60 feet away from the top of bank with depths above 20 feet in some locations. It would be financiallv unfeasible to construct the sewer outside the buffer area. 4. Explain whether the hardship was caused by the applicant knowingly or unknowingly violating the applicable Buffer Rule. No rules have been violated and we started working with NCDEQ in November of 2017 for guidance on the buffer rules and variance requirements. 5. For Neuse, Tar -Pamlico, Jordan Lake and Goose Creek only: Did the applicant purchase the property after the effective date of the applicable Buffer Rule and then request a variance? Charlotte Water does not own the property in question but has a permanent and temporary easement for the construction and maintenance of the sewer line. Easements have been purchased and were acquired after the effective date of buffer rules. FORM: VAR 10-2013 Page 6 of 7 6. Explain how the hardship is rare or unique to the applicant's property, rather than the result of conditions that are widespread. This proiect is unique in that it is restoring a stream and constructing a gravity sewer all under one proiect to be constructed at the same time. This allowed for an overall reduction in clearing where we adjusted the sewer alignment with input from NCDEQ and utilized overlapping areas of the stream restoration for temporary easement thus reducing the upland clearing reauired to comDlete the work. F. Deed Restrictions By your signature in Section G of this application, you certify that all structural stormwater BMPs required by this variance shall be located in recorded drainage easements, that the easements will run with the land, that the easements cannot be changed or deleted without concurrence from the State, and that the easements will be recorded prior to the sale of any lot. G. Applicant's Certification I, J 0,-S o L MA 5 kA, �� (print or type name of person listed in Section A, Item 2), certify that the information included on this permit application form is correct, that the project will be constructed in conformance with the approved pla7a,,,that the deed restrictions in accordance with Section F of this form will be recorded with all required permit conditions. Signature: Date: FORM: VAR 10-2013 Page 7 of 7 Stevens Creek Trunk Sewer -Phase 1 Sewer Permanent Temporary Property Deed Book & Record Plat Map Easement Area Access Easement Description Plat Number Parcel ID Owner Property Address Page Book &Page (SF) Area (SF) DB PG MB PG Easement is mostly wooded with small to mid size trees, with some *WEST of* 15724 wetland areas. Easement is mostly within the 100-year floodplain 1 19514101 Mecklenburg County Thompson Rd, 30459 495 36,922 7,721 and parallel to Stevens Creek. Some wetland and drainage channel Charlotte NC 28227 disturbance will take place with restoration occurring after construction. Easement is mostly wooded with several large trees along the Mecklenburg County alignment. Easement areas have been coordinated to coincide with 2 19524101 C/O Real Estate/Finance 15700 Thompson Rd, 12412 394 120,889 68,296 clearing of stream restoration project. Easement moves in and out CharlotteNC 28227 , Dept of 100-year floodplain boundary and includes wetland areas, drainage channels and a crossing of Stevens Creek. Easement is an existing utility easement that is mostly wooded Mecklenburg County 3 19523106 C/O Real Estate/Finance 14925 Hooks Rd, 12412 394 8,140 6,303 with small to mid size trees. Some areas have previously been Matthews NC 28105 cleared for access with heavy underbrush. Easement moves in and Dept out of 100-year flood plain and parallel to Stevens Creek. Easement is mostly wooded with small to mid size trees. Easement moves in and out of the 100-year floodplain boundary, parallel to 14642 Thompson Rd 4 19510136 Clyde Turner Charlotte NC 28227 5218 4 6 245 19,313 12,659 Stevens Creek, and includes drainage channels. Some drainage channel disturbance will take place with restoration occurring after construction. 14618 Thompson Rd Easement is mostly wooded with small to mid size trees. Easement 5 19510137 Clyde Turner 13710 684 6 245 3,270 2,009 Charlotte NC 28227 is within the 100-year floodplain and parallel to Stevens Creek. Easement is mostly wooded with small to mid size trees. Easement is within the 100-year floodplain boundary parallel to Stevens 14604 Thompson Rd 6 19510101 Meeta Turner Charlotte NC 28227 10105 273 6 245 19,565 24,897 Creek, and includes drainage channels. Some drainage channel disturbance will take place with restoration occurring after construction. Easement area encompasses residential lawn with no trees. 14709 Thompson Rd 7 19506127 Ronald Cox Charlotte NC 28227 6321 345 12 433 12,982 1,295 Easement is within the 100-year floodplain boundary and parallel t Stevens Creek. Easement is mostly wooded with small to mid size trees. Easement is within the 100-yearfloodplain and parallel to Stevens Creek and James and Mitzi 15550 Thompson Rd 8 19517155 Wiggins Charlotte NC 28227 8064 520 26 598 21,957 15,557 Stevens Creek Tributary. Some wetland area, drainage channels and existing fencing disturbance will take place with restoration occurring after construction. Easement is lightly wooded with small to mid size trees and open *NEAR/BEHIND* field areas with some wooded wetland areas. Easement moves in 9 19517150 Robert A Winfrey 15432 Thompson Rd 2996 144 15,565 37,440 and out of the 100-year floodplain boundary, parallel to Stevens Charlotte NC 28227 Creek Tributary. Some wetland disturbance will take place with restoration occurring after construction. Easement is mostly wooded with small to mid size trees. Easement Clay and Jennifer 15401 Thompson Rd 10 19508105 Littlefield Charlotte NC 28227 30900 385 6,316 11,473 is within the 100-year floodplain boundary parallel to Stevens Cree Tributary. Easement is located at the boundary of a horse pasture with mostly grass and some occasional light brush and small to mid size trees. 5502 Dressage BV, Easement moves in and out of the 100-year floodplain boundary 11 19508131 Cheval Associates LLC 19418 1 44 425 30,260 44,333 Charlotte NC 28227 parallel to Stevens Creek Tributary. Some existing fence disturbance will take place with restoration occurring after construction. Stevens Creek Trunk Sewer -Phase 1 Sewer Permanent Temporary Property Deed Book & Record Plat Map Easement Area Access Easement Description(SF) Plat Number Parcel ID Owner Property Address Page Book &Page Area (SF) DB PG MB PG Easement is lightly wooded with small to mid size trees and a few 12 19517148 Mecklenburg County N/A 24891 862 278 777 large trees. Easement is within the 100 -year floodplain boundary and crosses Stevens Creek. Easement is mostly cleared with mostly small to mid size trees near Stevens Creek. Some large trees are located near the creek along 13 19517147 City of Charlotte N/A 30613 431 22 60 2,808 3,780 the alignment. Easement includes a crossing of Stevens Creek, and existing fence disturbance with restoration occurring after construction. SAMPLE AGENT AUTHORIZATION FORM PROPERTY LEGAL DESCRIPTION: LOT NO. See Attachment PLAN NO. STREET ADDRESS: See Attachment Please print: Property Owner: Property Owner: See Attachment See Attachment PARCEL ID: The undersigned, registered property owners of the above noted property, do hereby authorize Jason Marshall of GHD, Inc. (Contractor / Agent) (Name of consulting firm) to act on my behalf and take all actions necessary for the processing, issuance and acceptance of this permit or certification and any and all standard and special conditions attached. Property Owner's Address (if different than property above): 222 South Church Street, Suite 400, Charlotte, NC 28202 Telephone: 704-342-4913 We hereby certify the above information submitted in this application is true and accurate to the best of our knowledge. Authorized Signature ori d Si at Date: 2/26/18 Site Plans �IIMlj�!', �\ _ ��.j //_ ✓� / -;, ,; �i1 H V1�-f \,� � �"� % �� ✓ � eT� i 'L` %, �, - ---/ X11 '`�//�I� i � \\�--���- - / i'iiII/�✓ /o /�y�- - -77 FT -1/6 ER1 r \�\ PosEo R&v—aTr+ER-s � � \ � FT�` R boa- �uF-[�� - --'� ��ie,Ei,� � FNT F ALIGNMENT- 0 u_wMEvL wr q,� I(I �,� 1, � �`I I I i ; , `✓/ ' r � � ; ' I --\�� -' 'a � i ! �� �I i� -f R ET�7Rrl �—_'� ` \ w c' "Tri � � `L � � ��'�-� o�E is v 6RE-�w--1' �iT s� �, � �_--' i�\ �� ��I `, \ � \ 'v � ' ` ,,I�✓ /�— ��� —_ � 'i r`, 1,S MZX N , \A HA E C) c�inaLF F ,F kx H E VA EVA 101 LEGENDSEWER ALIGNMENT o TEMPORARY EASEMENT 50 -FT BUFFER 1 7 30 -FT BUFFER / r,EEUNE .eeef'— FPROPOSED�F s�� STREAM CNK �� Q r. CL F, mIf�A�Y�_ //'��\\. �`Y> -_. ��\� Suite 400, CharlotteN. 28202Li i JD STREAM CROSSING S3 8 JD STREAM CROSSING S4 i ° o0 0 o O o \ ° • o / o ° o ° o ° o 0 ° ° o ° ° °° °° ° J EAM CROSSING S5 ° , \ o o ° o ° , o �-.. ... \ ' 30' PERMANENT EA'SEMENT / FUTURE SS EXTENSION W/ 20' STREAM SIDE 0 /\\ -- ) TEMP EASEMENT WETLAND Q � PROPOSED PS B OTHERS \ JD STREAM CROSSING S1 / \ 20 FT BUFFER ' 40' PFRMANFNT EASEMENT W 16' STREAM SIDE TEMP EASEMENT \ JD STRE C G S6 / °°°°O TP TIE IN LOC IC ETLAND DISTURBANCE 4 . .. 0 IMPACT AREA — 0.06 AC 00 ° WETLAND .;il \`- -- -- — \ O----- -- °° � -----� \ WETLAND DISTURBANCE ° WETLAND DISTURBANCE 3 \.� o °° ° IMPACT AREA 0.07 AC O IMPACT� AREA — 0.11 AC / O o I I \\ ° PROPOSED STEVENS CREEK ° i o ° o NATURE CENTER W/ 30' STREAM SIDE \'�, o I TEMP EASEMENT \, \ 1 TEMPORARY E SEMENT \\ ° \° � o I 0 o \ \ \ N RO P� \ I0 \ ° 1 200—FT BUFFER o ° o° ° \ WETLAND DISTURBANCE 1 \ \ \ — IMPACT AREA — 0.06 AC \ I \ 20' PERMANENT EASEMENT \ W/ 30' UPLAND SIDE \ TEMP EASEM E T \ CHEVAL PROPERTY J0L1 CHEVAL L I \ I 1EI\1S CREE S UTFA L'A AND B '/I� 1 y I I I I I �x WETLAND 000 of * 0 FERIIIIIIIIIIIIIIIIIIIIiiiiiililllllI-'I A P i LEGEND SEWER ALIGNMENT — — PERMANENT EASEMENT TEMPORARY EASEMENT 200—FT BUFFER — —EXISTING CREEK PERMANENT EASEMENT TEMPORARY EASEMENT MAINTENANCE EASE. � WETLAND DISTURBANCE TREELINE \� f— PROPOSED STREAMBANK Q 1 "=150' � GHD, 222 South Church Street, Suite 400, Charlotte NC 28202 LEGEND TEMPORARY CONSTRUCTION EASEMENT— TCE TCE TCE I 3Ul 301 301 J STAGING AREA r J TEMPORARY CONSTRUCTION ENTRANCE EROSION CONTROL MATTING NOTE: LINE WEIGHTS ARE NOT DELINEATED HERE, THEY ARE CONTROLLED THROUGH CLTWater PLOTSTYLE, DESIGN COMPANY: GHD CONSULTING SERVICES INC. ADDRESS: 222 S. CHURCH STREET, SUITE 400, CHARLOTTE, NC 28202 PHONE: (704) 342-4910 DATE DESIGN COMPLETED: - SURVEY COMPANY: LAWRENCE ASSOCIATES ADDRESS: 106 W. JEFFERSON STREET, MONROE, NC 28112 PHONE: (704) 289-1013 DATE SURVEY COMPLETED: - GEOTECHNICAL COMPANY: JOEL E. WOOD & ASSOCIATES ADDRESS: P.O. BOX 2961 CLOVER, SC 29710 PHONE: (803) 684-3390 DATE COMPLETED: - CONTRACTOR: ADDRESS: - PHONE: - INSPECTOR: - INSIDE CHARLOTTE: ( ) YES (�) NO: TOPO NO: 138,139 CHARLOTTE "VV T E IR CHARLOTTE, NORTH CAROLINA INDEX OF SHEETS SHEET NO. 1 SYMBO ASPHALT (PROFILE) STA B19+00 TO STA B31+00 BOTTOM OF BANK (TOE) — — — — — SHEET NO. 15 STA C0+00 TO STA C2+75 BRIGDE KEY MAP SHEET NO. 16 BUILDING CHECK DAM STD. 6.83 �► �► CONCRETE (PROFILE) MANHOLE DETAILS (SHEET 2 OF 2) EXISTING CREEK STA A9+00 TO STA A18+00 PROPOSED CREEK #a M0 as CURB & GUTTER STA A18+00 TO STA A24+00 EDGE OF ROADWAY ------------- EXISTING � SANITARY SEWER —ss EXIST. SAN. SEWER MANHOLE STRUCTURE STANDARD SEWER DETAILS (SHEET 1 OF 2) EXISTING GAS MAIN G EXISTING GAS SERVICE GS FENCE (LABEL TYPE) X X GAS VALVE GV GRAVEL (PROFILE) STA A49+00 TO STA A58+00 GROUND PROFILE EROSION CONTROL DETAILS (SHEET 1 OF 3) GUARD RAIL STA A58+00 TO STA A66+00 MARSH, POND, WETLAND OR LAKE EROSION CONTROL DETAILS (SHEET 2 OF 3) OVERHEAD ELECTRIC OE SHEET NO. 25 EROSION CONTROL DETAILS (SHEET 3 OF 3) PIERS POWER POLE/GUY WIRE r 0EITHER / OR PROPERTY LINE — — BORE HOLE SHEET NO. C302 6" SEWER CONSTRUCTION PROPOSED � SANITARY SEWER N89ro0'00"E 26.80' PROP. SAN. SEWER MANHOLE STRUCTURE RIP — RAP GRAVITY ROAD/STREET R/W RW SEDIMENT FENCE (SILT FENCE) STD. 6.62 CHARLOTTE WATER SIDEWALK STREET SIGN (LABEL TYPE) STORM DRAIN/CATCH BASIN, YARD AND DROP INLET TEMPORARY SEDIMENT TRAP STD. 6.60 (� TEMPORARY ROCK SEDIMENT DAM ROCK SILT CHECK SILT BASIN STONE CHECK DAM TEMPORARY DIVERSION STD. 6.20 TD TD TD TEMPORARY SILT DITCH TSD TSD TEMPORARY STREAM CROSSING STD. 6.70 �T� PROPOSED TOP OF BANK (TOB) TOWER LINE of TREE & BUSH TREE UNE UNDERGROUND CABLE UC UNDERGROUND ELECTRIC UE UNDERGROUND TELEPHONE UT UT PROPOSED SANITARY SEWER (BY OTHERS) SS SS WATER METER ❑ 100 YEAR FLOOD PLAIN — — — — — — 50' WETLAND BUFFER 200' BUFFER MAJOR CONTOUR — MINOR CONTOUR PROP. PERM. SEWER EASEMENT 3nsd PSUE TEMPORARY CONSTRUCTION EASEMENT— TCE TCE TCE I 3Ul 301 301 J STAGING AREA r J TEMPORARY CONSTRUCTION ENTRANCE EROSION CONTROL MATTING NOTE: LINE WEIGHTS ARE NOT DELINEATED HERE, THEY ARE CONTROLLED THROUGH CLTWater PLOTSTYLE, DESIGN COMPANY: GHD CONSULTING SERVICES INC. ADDRESS: 222 S. CHURCH STREET, SUITE 400, CHARLOTTE, NC 28202 PHONE: (704) 342-4910 DATE DESIGN COMPLETED: - SURVEY COMPANY: LAWRENCE ASSOCIATES ADDRESS: 106 W. JEFFERSON STREET, MONROE, NC 28112 PHONE: (704) 289-1013 DATE SURVEY COMPLETED: - GEOTECHNICAL COMPANY: JOEL E. WOOD & ASSOCIATES ADDRESS: P.O. BOX 2961 CLOVER, SC 29710 PHONE: (803) 684-3390 DATE COMPLETED: - CONTRACTOR: ADDRESS: - PHONE: - INSPECTOR: - INSIDE CHARLOTTE: ( ) YES (�) NO: TOPO NO: 138,139 CHARLOTTE "VV T E IR CHARLOTTE, NORTH CAROLINA INDEX OF SHEETS SHEET NO. 1 COVER SHEET SHEET NO. 14 STA B19+00 TO STA B31+00 SHEET NO. 2 GENERAL NOTES AND MANHOLE SCHEDULE SHEET NO. 15 STA C0+00 TO STA C2+75 SHEET NO. 3 KEY MAP SHEET NO. 16 MANHOLE DETAILS (SHEET 1 OF 2) SHEET NO. 4 STA A0+00 TO STA A9+00 SHEET NO. 17 MANHOLE DETAILS (SHEET 2 OF 2) SHEET NO. 5 STA A9+00 TO STA A18+00 SHEET NO. 18 24 IN. MANHOLE FRAME AND COVER DETAILS SHEET NO. 6 STA A18+00 TO STA A24+00 SHEET NO. 19 30 IN. MANHOLE FRAME AND COVER DETAILS SHEET NO. 7 STA A24+00 TO STA A35+00 SHEET NO. 20 STANDARD SEWER DETAILS (SHEET 1 OF 2) SHEET NO. 8 STA A35+00 TO STA A43+00 SHEET NO. 21 STANDARD SEWER DETAILS (SHEET 2 OF 2) SHEET NO. 9 STA A43+00 TO STA A49+00 SHEET NO. 22 EROSION CONTROL NOTES SHEET NO. 10 STA A49+00 TO STA A58+00 SHEET NO. 23 EROSION CONTROL DETAILS (SHEET 1 OF 3) SHEET NO. 11 STA A58+00 TO STA A66+00 SHEET NO. 24 EROSION CONTROL DETAILS (SHEET 2 OF 3) SHEET NO. 12 STA 130+00 TO STA 67+00 SHEET NO. 25 EROSION CONTROL DETAILS (SHEET 3 OF 3) SHEET NO. 13 STA 137+00 TO STA B19+00 SHEET NO. 26 FENCE DETAILS SHEET NO. C302 6" SEWER CONSTRUCTION APPLICATION FOR NON -DISCHARGE PERMIT GRAVITY SEWER MAIN EXTENSION CHARLOTTE WATER PROJECT NAME SANITARY SEWERAGE SYSTEM IMPROVEMENTS CREEK BASIN STEVENS CREEK Tr H A'S� E v` `ol 0� O= w M j o°aO Ezell Farm �' t Ci r Community 7� 2) _ M Parc d stone dr U n to v � � N I i d Oak pr Q I 1 N tiRd L, �� o �rornps°nNol1o* Ln �I 410 " Q i 0 o PROPOSED SEWER G '400 6s C°U(�tty c` Oaks n'. O - LZ o cow �k Or 0', Lr Linen' 04o 'Aa oStevens Creek O,, w / Lake B%"-% O a,- r `61e -, • • had°w dr LakE Ln °ok O� Steven s - 5 Creek Nature Pre se rve Mill House Ln 'Thom Rd ° f3 tj r n t M;// tiTr �\ a Ap 04 1 // QRZ t 1)coo y Qi r a I ,fin The a p ore Ln � r R t I � � Divide �� w• B C� O Nancy �' hAbergele l n v i v, v �•�r Hook Rd P. . ° (fig 1� e SOURCE: ESRI, DELORME, USGS, INTERMAP, NRCAN, NGCC, © OPENSTREETMAP CONTRIBUTORS LOCATION MAP (NTS) GHD PROJECT NO.: 111-23681 GHD Consulting Services Inc. 222 South Church Street, Suite 400 Charlotte NC 28202 USA T 1 704 342 4910 W www.ghd.com STEVENS CREEK TRUNK SEWER CLTWater PROJECT NO.: 7030700047-17-503 PROJECTTYPE: ❑X NEW CONSTRUCTION ❑RELOCATION ❑MODIFICATION OF PERMIT NO. OTHER VOLUME OF WASTEWATER GENERATED BY THIS PROJECT: 930,000 GALLONS PER DAY BASED ON 250 GAL/DAY/EQUIVALENT RESIDENTIAL UNIT (ERU) 3720 ERUs OR 135 GAL/DAY/MULTI-FAMILY UNIT X * UNITS OR IS BASED ON WASTEWATER TREATMENT PLANT RECEIVING WASTEWATER: Z McALPINE CR. (NC0024970) ❑ IRWIN CR. (NC0024945) ❑ McDOWELL CR. (NC0036277) ❑ SUGAR CR. (NC0024937) ❑ MALLARD CR. (NC0030210) ❑ ROCKY CR. (NC0036269) NATURE OF WASTEWATER 100 % DOMESTIC % INDUSTRIAL % COMMERCIAL % OTHER ORIGIN OF WASTEWATER ❑ SUBDIVISION ❑ COMMERCIAL ❑ SCHOOL ❑ INDUSTRIAL ❑ APARTMENTS/CONDO'S ❑X OTHER EXISTING DEVELOPMENT (RESIDENTIAL) LIST ANY PARAMETER AND ITS CONCENTRATION THAT WILL BE GREATER THAN NORMAL DOMESTIC LEVELS: NONE IF WASTEWATER IS NON-DOMESTIC, DESCRIBE LEVEL OF PRETREATMENT: IF A PRETREATMENT PERMIT IS REQUIRED, HAS ONE BEEN ISSUED? ❑YES ❑ NO HAS ENGINEER DETERMINED THAT DOWNSTREAM SEWERS ARE CAPABLE TO HANDLE THIS FLOW? ❑X YES ❑ NO PERMIT NO. FOR SEWERS IMMEDIATELY DOWNSTREAM TBD PIPE DIAMETER OF SEWERS IMMEDIATELY DOWNSTREAM PROPOSED STEVENS CREEK PS (BY OTHERS) HAS ENGINEER DETERMINED THAT NC DEM AND CLTWater MINIMUM DESIGN STANDARDS ARE MET BY THIS PROJECT? ❑X YES ❑ NO COMPLETE NAME AND ADDRESS OF ENGINEERING DESIGN FIRM: GHD CONSULTING SERVICES INC. 222 S. CHURCH STREET SUITE 400 CHARLOTTE, NORTH CAROLINA 28202 TELEPHONE 704 342 4910 PROFESSIONAL ENGINEER'S CERTIFICATION: MICHAEL E. BISIGNANI ATTEST THAT THIS APPLICATION FOR SANITARY SEWERAGE SYSTEM IMPROVEMENTS STEVENS CREEK TRUNK SEWER HAS BEEN REVIEWED BY ME AND IS ACCURATE AND COMPLETE TO THE BEST OF MY KNOWLEDGE. I FURTHER ATTEST THAT TO THE BEST OF MY KNOWLEDGE THE PROPOSED DESIGN HAS BEEN PREPARED IN ACCORDANCE WITH THE APPLICABLE REGULATIONS. ALTHOUGH CERTAIN PORTIONS OF THIS SUBMITTAL PACKAGE MAY HAVE BEEN DEVELOPED BY OTHER PROFESSIONALS, INCLUSION OF THESE MATERIALS UNDER MY SIGNATURE AND SEAL SIGNIFIES THAT I HAVE REVIEWED THIS MATERIAL AND HAVE JUDGED IT TO BE CONSISTENT WITH THE PROPOSED DESIGN. NORTH CAROLINA PROFESSIONAL ENGINEER'S SEAL, SIGNATURE, AND DATE CLTWater PERMIT NO. PLANT FLOW ALLOCATION RECORDED BY: PERMIT APPROVED BY: FINAL DESIGN NOT FOR CONSTRUCTION CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHARLOTTE WATER STANDARD SPECIFICATIONS. ISSUED JOSEPH C WILSON, P.E., CHIEF ENGINEER APPROVAL SEAL N. C. P. E. SUMMARY OF SEWER MAINS & MANHOLES SIZE LENGTH SIZE LENGTH 24" 2490' 8" 27' 16" 4060' 12" 3325' TOTAL NO. OF MANHOLES: 32 TOTAL NO. LOTS SERVED: 3680 PROJECT NAME: SANITARY SEWER SYSTEM IMPROVMENTS STEVENS CREEK TRUNK SEWER JOB NO: 7030700047-17-503 DATE OF ACTIVATION: DATE AS BU I LT: BY: A CITY OF CHARLOTTE DEPARTMENT GENERAL NOTES: 1. CONSTRUCTION SHALL BE IN ACCORDANCE WITH CHARLOTTE WATER STANDARDS, SPECIFICATIONS, AND CONTRACT DOCUMENTS. 2. ALL ELEVATIONS REFER TO DATUM NAVD88. 3. THE CONTRACTOR SHALL OBTAIN ALL ADDITIONAL PERMITS NECESSARY NOT PROVIDED IN CONTRACT DOCUMENTS AND FURNISH COPIES TO THE ENGINEER PRIOR TO COMMENCING WORK. 4. THE CONTRACTORS WORK AREA SHALL BE CONFINED TO THE LIMITS OF THE RIGHT-OF-WAYS AND EASEMENTS. THE CONTRACTOR SHALL OBTAIN ANY ADDITIONAL EASEMENTS OR WORK RELEASES SHOULD THE CONTRACTOR REQUIRE ADDITIONAL AREA TO ACCOMMODATE HIS OPERATIONS. A COPY OF WRITTEN AGREEMENTS SHALL BE FURNISHED TO CHARLOTTE WATER. 5. THE CONTRACTOR SHALL PROVIDE MAINTENANCE AND PROTECTION OF TRAFFIC IN ACCORDANCE WITH MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES (MUTCD) AND NCDOT STANDARDS AND DRAWINGS FOR WORK ZONE TRAFFIC CONTROL. 6. THE LOCATIONS AND DEPTHS OF EXISTING UNDERGROUND UTILITIES AS SHOWN ON THE PLANS AND PROFILES ARE APPROXIMATE. OTHER UNDERGROUND UTILITIES NOT SHOWN MAY BE ENCOUNTERED. THE CONTRACTOR SHALL PERFORM SOFT -DIGS TO VERIFY THE LOCATION AND ELEVATION OF UTILITIES AT INTERCONNECTIONS AND CROSSINGS AS SHOWN, DIRECTED OR REQUIRED. THE CONTRACTOR SHALL EXCAVATE IN ADVANCE OF THE PIPE LAYING OPERATION AND EXPOSE ALL EXISTING UNDERGROUND UTILITIES TO PREVENT DAMAGE DURING CONSTRUCTION AND TO DETERMINE REQUIRED CHANGES IN GRADE NECESSARY TO INSTALL THE SEWERMAIN TO AVOID CONFLICTS. 7. THE CONTRACTOR SHALL INSTALL THOSE MEASURES REQUIRED TO LIMIT EROSION OF AREAS DISTURBED BY THE WORK. CLEARING SHALL BE PERFORMED TO THE EXTENT SHOW OR ON AN AS NEEDED BASIS, WHICHEVER IS LESS, PHASED TO REDUCE EROSION POTENTIAL AND VISUAL IMPACT. 8. BLASTING WILL ONLY BE PERMITTED IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. 9. ONLY CHARLOTTE WATER SHALL OPERATE EXISTING VALVES AND FIRE HYDRANTS. 10. ALL SEWER PIPING SHALL BE INSTALLED WITH MINIMUM COVER OF 3'-0". IF MINIMUM COVER CANNOT BE OBTAINED, THE SEWER MAIN LOCATION SHALL BE REVIEWED AND APPROVED BY THE ENGINEER AND OWNER AND SHALL BE ENCASED IN CONCRETE. 11. MINIMUM PIPE SEPARATION: 10' HORIZONTAL SEPARATION OR 18" VERTICAL SEPARATION SHALL BE MAINTAINED BETWEEN WATER MAINS OVER SEWER MAINS. WHEN WATER MAINS ARE BELOW SEWER MAINS OR THE ABOVE MINIMUM SEPARATION CANNOT BE MAINTAINED, DUCTILE IRON PIPE SHALL BE USED FOR BOTH MAINS TO 10' EITHER SIDE OF CROSSING, AND ALL ALONG THE LENGTH OF MAINS WHERE MINIMUM SEPARATION CANNOT BE MAINTAINED. 12. IF THE MATERIAL AT THE DESIGN GRADE IS UNSUITABLE AS DETERMINED BY THE ENGINEER, THE CONTRACTOR, WHEN ORDERED IN WRITING, SHALL EXCAVATE ADDITIONAL MATERIAL TO THE DEPTH NECESSARY AND SHALL BACKFILL TO THE PROPOSED GRADE WITH SELECT GRANULAR BACKFILL MATERIAL. 13. THE CONTRACTOR SHALL NOTIFY THE OWNER OF ANY UTILITY POLE IN ADVANCE OF ANY EXCAVATION WORK THAT WILL TAKE PLACE WITHIN 5'-0" OF THE UTILITY POLE. THE CONTRACTOR SHALL INCLUDE THE COST OF TEMPORARY POLE SUPPORT IN THE APPROPRIATE BID ITEM. WHERE UTILITY POLES ARE REQUIRED TO BE SUPPORTED DURING CONSTRUCTION, THE CONTRACTOR SHALL MAKE ALL NECESSARY ARRANGEMENTS WITH THE UTILITY COMPANY (DUKE POWER). 14. IF MATERIALS ARE ENCOUNTERED DURING THE CONSTRUCTION THAT ARE SUSPECTED OF BEING CONTAMINATED, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE NCDEQ FOR DIRECTION REGARDING TESTING, SEPARATION, CONTAINMENT AND DISPOSAL PROCEDURES. 15. IF A PROPOSED SEWER CONFLICTS WITH A SUBSURFACE OBSTRUCTION AND WHEN THE MINIMUM COVER CANNOT BE MAINTAINED BY GOING ABOVE THE OBSTRUCTION, THE CONTRACTOR SHALL INSTALL THE SANITARY SEWER BELOW THE OBSTRUCTION MAINTAINING THE APPROPRIATE SEPARATION AND GRADE. 16. CONTRACTOR SHALL REPAIR ALL TRENCH EXCAVATIONS IN TRAVELED AREAS INCLUDING ROADS, DRIVEWAYS, SIDEWALKS AND PARKING AREAS TO MEET OWNER'S REQUIREMENTS. 17. THE USE OF EXISTING FIRE HYDRANTS FOR ANY REASON IS PROHIBITED WITHOUT PRIOR APPROVAL AND PERMITTING OF CHARLOTTE WATER. 18. THE CONTRACTOR SHALL SUBMIT IN ACCORDANCE WITH CONTRACT DOCUMENTS PROCEDURES FOR TESTING OF THE SEWER TO THE ENGINEER FOR APPROVAL. 19. THE CONTRACTOR SHALL BE PRESENT AND ASSIST IN THE FINAL WALK INSPECTION. THE CONTRACTOR SHALL PROVIDE SUFFICIENT PERSONNEL AND EQUIPMENT TO DEMONSTRATE TO THE ENGINEER THAT ALL EQUIPMENT OPERATES AS REQUIRED. 20. TO FACILITATE INSTALLATION OF THE NEW SEWER AND APPURTENANCES, THE CONTRACTOR SHALL REMOVE AND REINSTALL, OR RELOCATE EXISTING MAILBOXES, SIGNS, GUIDE RAILS, OR OTHER STRUCTURES AND OBSTACLES ENCOUNTERED DURING THE WORK. NO SEPARATE PAYMENT SHALL BE PAID FOR THIS WORK. 21. ALL OPEN EXCAVATED AREAS SHALL BE ADEQUATELY MARKED, SECURED WITH TEMPORARY FENCING WITH A MINIMUM HEIGHT OF 6 FEET, AND/OR COVERED WITH STEEL PLATE AT THE END OF EACH WORK DAY. 22. CONTRACTOR SHALL REMOVE AND REPLACE CURBS, SIDEWALKS, DRIVEWAYS, MAILBOXES, ETC. TO LIKE KIND CONDITION OR BETTER AS NECESSARY TO ACCOMMODATE CONSTRUCTION OF THE PROPOSED UTILITIES HERE IN. 23. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND FIELD MEASUREMENTS. THE CONTRACTOR MUST CONTACT ALL APPROPRIATE UTILITY COMPANIES AT LEAST A 3 WORKING DAY NOTICE PRIOR TO ANY EXCAVATION TO REQUEST DETAILED FIELD LOCATION OF EACH UTILITY. THE CONTRACTOR IS RESPONSIBLE TO CONTACT NORTH CAROLINA 811 AT 1-800-632-4949 OR 811 FOR UTILITY MARK OUT PRIOR TO THE START OF ANY EXCAVATION WORK ON THIS PROJECT. 24. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS PERTINENT TO THE WORK OF THE CONTRACT. NO ALLOWANCE SHALL BE MADE ON BEHALF OF THE CONTRACTOR FOR ANY ERROR OR NEGLECT ON HIS PART. 25. ALL SURFACES DISTURBED BY THE CONTRACTOR WHICH ARE OUTSIDE THE WORK LIMITS OR WORK SCOPE, OR ARE SURFACES DISTURBED WITHOUT PRIOR AUTHORIZATION BY THE ENGINEER, SHALL BE RESTORED TO ORIGINAL CONDITIONS OR BETTER, AT THE CONTRACTOR'S EXPENSE. 26. CONTRACTOR SHALL FIELD LOCATE ALL SEWER LATERALS, WATER SERVICES, AND OTHER SERVICES PRIOR TO CONSTRUCTION. CONTRACTOR SHALL REPAIR ANY DAMAGED SEWER LATERALS, WATER SERVICES, AND OTHER SERVICES AS A RESULT OF CONSTRUCTION AT HIS OWN EXPENSE. 27. THE CONTRACTOR SHALL PERFORM ALL WORK NECESSARY, WITHOUT INTERRUPTION TO EXISTING SANITARY SERVICES. THE CONTRACTOR SHALL UTILIZE APPROVED BYPASSING TECHNIQUES IN ORDER TO PERFORM SAID WORK UNDER SAID CONDITIONS. ALL PROPOSED BYPASSING TECHNIQUES AND EQUIPMENT SHALL BE SUBMITTED TO THE ENGINEER FOR REVIEW AND APPROVAL PRIOR TO THE START OF THIS WORK. THE COST FOR THIS WORK SHALL BE INCLUDED IN THE UNIT PRICES BID FOR THIS PROJECT. NO ADDITIONAL COMPENSATION WILL BE PROVIDED FOR THIS WORK. 28. IN THE EVENT THAT A SERVICE MUST BE INTERRUPTED, THE CONTRACTOR SHALL BE SOLELY RESPONSIBLE TO NOTIFY THE RESIDENT OF SAID INTERRUPTION. IN NO CASE SHALL ANY SERVICE BE INTERRUPTED FOR MORE THAN 6 -HOURS, AND IN NO CASE SHALL THE INTERRUPTION EXTEND BEYOND THE END OF THE WORKING DAY. IN THE EVENT THAT ANY INTERRUPTION CONTINUES FOR MORE THAN 6 -HOURS, THE CONTRACTOR SHALL PROVIDE TEMPORARY SERVICES. NO ADDITIONAL COMPENSATION WILL BE PROVIDED FOR WORK ASSOCIATED WITH ALL SUCH TEMPORARY SERVICES. 29. WHEN WORK INCLUDED UNDER THIS PROJECT, AS INDICATED BY THE PROJECT CONTRACT DOCUMENTS, REQUIRES THE REMOVAL OF EXISTING PAVED SURFACES, TO INCLUDE BUT NOT BE LIMITED TO, ROADWAYS, DRIVEWAYS, SIDEWALKS, AND PARKING LOTS, THE CONTRACTOR SHALL BE REQUIRED TO SAW -CUT THE LIMITS OF THE PROPOSED EXCAVATION PRIOR TO EXCAVATION OF SAID AREA. THE CONTRACTOR SHALL BE REQUIRED TO PROVIDE AND MAINTAIN TEMPORARY RESTORATION OF ALL SUCH AREAS, UNTIL PERMANENT RESTORATION IS PROVIDED. NO ADDITIONAL COMPENSATION SHALL BE PROVIDED FOR ALL SUCH SAW CUTTING AND TEMPORARY RESTORATION. 30. SUBSURFACE INVESTIGATIONS HAVE BEEN PERFORMED IN THE AREAS IN WHICH WORK IS PROPOSED. IT SHALL BE THE CONTRACTORS RESPONSIBILITY TO DETERMINE IF ANY ADDITIONAL SUBSURFACE INVESTIGATIONS ARE NECESSARY. NO ADDITIONAL COMPENSATION WILL BE PROVIDED FOR ANY SUCH WORK. IN THE EVENT THAT TRENCH EXCAVATION BECOMES DIFFICULT DUE TO THE MATERIAL ENCOUNTERED, THE ENGINEER SHALL DETERMINE WHETHER ADDITIONAL COMPENSATION SHALL BE PROVIDED FOR ALL SUCH EXCAVATING. THE CONTRACTOR SHALL REFER TO THE PROJECT SPECIFICATIONS FOR FURTHER INTERPRETATION OF WHEN SUCH ADDITIONAL ALLOWANCES WILL BE MADE, AND WHAT IS CONSIDERED "ROCK" EXCAVATION. 31. UNDER THIS PROJECT, THE CONTRACTOR SHALL BE RESPONSIBLE TO RESTORE, ACCORDING TO THE PLANS AND SPECIFICATIONS, ALL AREAS DISTURBED AS A RESULT OF HIS WORK. 32. IN ALL CASES WHERE THE PLANS AND SPECIFICATIONS VARY, THE SPECIFICATIONS SHALL PREVAIL, UNLESS OTHERWISE ORDERED BY THE ENGINEER. 33. THE CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR, TO THE EXTENT SPECIFIED BY THE ENGINEER, ALL DAMAGED PAVEMENT AREAS, (OUTSIDE THE LIMITS OF EXCAVATION) DAMAGED AS A RESULT OF HIS (OR ANY OF HIS REPRESENTATIVES) OPERATIONS. NO ADDITIONAL COMPENSATION WILL BE PROVIDED FOR ALL SUCH WORK. 34. CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE RULES AND REGULATIONS FOR STATE, COUNTY AND CITY. 35. ALL SEWER MAINS SHALL MAINTAIN THE MINIMUM SEPARATION REQUIREMENTS AS SET FORTH BY THE NCDEQ STANDARDS, CHARLOTTE WATER AND SEWER POLICIES, PROCEDURES, STANDARDS AND SPECIFICATIONS MANUAL, MOST RECENT EDITION. 36. ALL PAVEMENT MARKINGS SHALL BE RECORDED BY THE CONTRACTOR PRIOR TO THE START OF CONSTRUCTION AND REPLACED TO PRE CONSTRUCTION LAYOUT AS APPROVED BY THE ENGINEER AND OWNER. (IF NECESSARY) 37. THE CONTRACTOR SHALL MAINTAIN TRAFFIC THROUGHOUT THE LENGTH OF THE CONTRACT IN ACCORDANCE WITH THE REQUIREMENTS OF DIVISION 11 - WORK ZONE TRAFFIC CONTROL OF THE NCDOT STANDARD SPECIFICATIONS FOR ROADS AND STRUCTURES AND TOWN OF MINT HILL STANDARDS AS THEY APPLY. 38. PRIOR TO THE START OF ANY CONSTRUCTION PHASE, ALL PROPOSED MAINTENANCE AND PROTECTION OF TRAFFIC RELATED WORK SHALL BE COMPLETE. THIS INCLUDES, WHERE APPLICABLE, ALL SIGNS, PAVEMENT MARKINGS, BARRIERS, DELINEATION (CONES, DRUMS, ETC.), PAVEMENT MODIFICATION AND OTHER RELATED WORK. 39. THE CONTRACTOR SHALL POST WARNING SIGNS AT ALL APPROACHES TO THE PROJECT AND AT CONSTRUCTION ENTRANCES. THE CONTRACTOR SHALL PROVIDE FLAG MEN WHEN AND WHERE NECESSARY. 40. CONSTRUCTION INGRESS AND EGRESS - THE CONTRACTOR SHALL KEEP TO A MINIMUM THE MOVEMENT OF CONSTRUCTION VEHICLES AND EQUIPMENT IN AND OUT OF DESIGNATED TRAVEL LANES. ONLY NECESSARY OR AUTHORIZED VEHICLES, AS DETERMINED BY THE ENGINEER, SHALL BE ALLOWED TO ENTER THE WORK AREA. 41. PUBLIC INGRESS AND EGRESS A. THE CONTRACTOR SHALL MAINTAIN ACCESS TO EXISTING PARKING LOTS AND DRIVEWAY ENTRIES AT ALL TIMES. B. THE CONTRACTOR SHALL PROVIDE PROPERTY OWNERS WITH PROPER ACCESS AND MINIMUM WIDTHS FOR THEIR DRIVEWAYS ACCORDING TO THE POLICY AND STANDARDS FOR ENTRANCES TO STATE HIGHWAYS AND SHALL MAINTAIN THEM THROUGH ALL PHASES OF WORK AND SHALL DELINEATE THESE BY MEANS OF SIGNS, CONES, AND/OR DRUMS. C. WHERE DIRECT ACCESS TO DRIVEWAYS IS NOT POSSIBLE DUE TO NECESSARY CONSTRUCTION OPERATIONS, THE CONTRACTOR SHALL PLAN ALTERNATE MEANS OF ACCESS AND SUBMIT SUCH PLANS TO THE ENGINEER AND CITY DPW FOR REVIEW BEFORE OPERATIONS COMMENCE. 42. PORTIONS OF THIS ALIGNMENT PASS THROUGH EXISTING ACTIVE HORSE PASTURES. WHEN WORK IS PERFORMED IN THIS AREA LIMITS OF CONSTRUCTION SHOULD BE ADEQUATELY FENCED AND PROTECTED TO PREVENT THE ENTRY OF ANIMALS ON ALL SIDES OF THE WORK, THIS INCLUDES ANY TRAVERSING ACROSS EASEMENTS. 43. CONTRACTOR SHALL RESTORE EXISTING FENCES, UNLESS SHOWN OTHERWISE, WITH EQUAL OR BETTER MATERIALS WHEN TEMPORARY FENCING IS REMOVED. STEVENS CREEK MANHOLE SCHEDULE MH NAME STATION MH TYPE SIZE & MATERIAL RIM COVER TYPE FRAME EXTERNAL VENT ELEVATION MH -01 (BY OTHERS) AO+00 PRECAST 5'0 CONCRETE 631.45 BY OTHERS BY OTHERS TBD MH -02 A3+37.83 PRECAST 5'0 CONCRETE 635.73 TYPE 4 (VENTED) TYPE D MH -03 A6+59.55 PRECAST 5'0 CONCRETE 637.92 TYPE 4 (VENTED) TYPE D MH -04 A9+84.54 PRECAST 5'0 CONCRETE 639.23 TYPE 4 (VENTED) TYPE D MH -05 A13+07.73 PRECAST 5'0 CONCRETE 636.52 TYPE 5 (SOLID) TYPE D MH -06 A16+26.79 PRECAST 5'0 CONCRETE 638.26 TYPE 5 (SOLID) TYPE D 639.41 MH -07 A20+38.27 PRECAST 5'0 CONCRETE 636.93 TYPE 5 (SOLID) TYPE D MH -08 A24+83.26 = B0+00 PRECAST 5'0 CONCRETE 641.12 TYPE 5 (SOLID) TYPE D 643.68 MH -09 A28+10.33 = CO+00 PRECAST 4'0 CONCRETE 650.43 TYPE 1 (VENTED) TYPE B MH -10 A32+32.51 PRECAST 4'0 CONCRETE 657.65 TYPE 1 (VENTED) TYPE B MH -11 A35+20.43 PRECAST 4'0 CONCRETE 650.30 TYPE 1 (VENTED) TYPE B MH -12 A38+53.42 PRECAST 4'0 CONCRETE 651.81 TYPE 3 (SOLID) TYPE B MH -13 A42+42.63 PRECAST 4'0 CONCRETE 655.34 TYPE 1 (VENTED) TYPE B MH -14 A45+99.11 PRECAST 4'0 CONCRETE 658.41 TYPE 1 (VENTED) TYPE B MH -15 A49+60.55 PRECAST 4'0 CONCRETE 663.26 TYPE 1 (VENTED) TYPE B MH -16 A53+63.26 PRECAST 4'0 CONCRETE 660.46 TYPE 3 (SOLID) TYPE B MH -17 A58+11.76 PRECAST 4'0 CONCRETE 662.82 TYPE 3 (VENTED) TYPE B MH -18 A62+54.79 PRECAST 4'0 CONCRETE 664.01 TYPE 3 (SOLID) TYPE B MH -19 A64+63.77 PRECAST 5'0 CONCRETE 666.03 TYPE 5 (SOLID) TYPE D MH -20 A65+48.00 PRECAST 5'0 CONCRETE 666.61 TYPE 5 (VENTED) TYPE D MH -21 B2+14.46 PRECAST 4'0 CONCRETE 643.04 TYPE 3 (SOLID) TYPE B MH -22 65+91.49 PRECAST 4'0 CONCRETE 644.98 TYPE 3 (SOLID) TYPE B MH -23 B9+84.20 PRECAST 4'0 CONCRETE 647.84 TYPE 5 (VENTED) TYPE B MH -24 B11+77.09 PRECAST 5'0 CONCRETE 649.12 TYPE 4 (VENTED) TYPE D MH -25 B12+71.21 PRECAST 5'0 CONCRETE 647.60 TYPE 3 (SOLID) TYPE D MH -26 B15+64.77 PRECAST 4'0 CONCRETE 649.33 TYPE 3 (SOLID) TYPE B MH -27 B17+97.41 PRECAST 4'0 CONCRETE 651.87 TYPE 3 (SOLID) TYPE B MH -28 B21+48.61 PRECAST 4'0 CONCRETE 653.60 TYPE 3 (SOLID) TYPE B 655.02 MH -29 B26+63.92 PRECAST 4'0 CONCRETE 653.93 TYPE 3 (SOLID) TYPE B MH -30 B30+79.35 PRECAST 4'0 CONCRETE 661.60 TYPE 1 (VENTED) TYPE B MH -31 C2+29.93 PRECAST - INSIDE DROP 5'0 CONCRETE 644.81 TYPE 3 (SOLID) TYPE B MH -32 C2+56.22 PRECAST - DOGHOUSE 4'0 CONCRETE 645.49 TYPE 3 (SOLID) TYPE B tR WZAf FI GHD Consulting Services Inc. 222 South Church Street, Suite 400 Charlotte NC 28202 USA T 1 704 302 4910 W www.ghd.com A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT � rn \ C7El �\ \ PROPOSED 12 SS - \ I /> �-EXISTING STEVENS CREEK TRIBUTARY� \ 1APS�N \ I ' , I PROPOSED STEVENS CREEK NATURE PRESERVE (BY OTHERS) BH -10 ' I PROPOSED MANHOLE (TYP) EXISTING OXFORD 4 GLENN PACKAGE WWTP\ EM F-1 �!SHEET 15 BH -2 / I EXISTING / STEVENS CREEK BH -3 ISI 6 PROPOSED 24 SS �,- PROPOSED STEVENS CREEK J/ I \ v PUMP STATION (BY OTHERS) I 0/ I _ - ' � , , ® � © ®� - � EXISTING STEVENS CREEK H-5 Q Hg��T4 H-9 0 PROPOSED 15 SS \ / © (� LEGEND• I \ ®\ \ ✓ \ ` ,' , . / I �eH-� BORE HOLE 4�1 • CONSTRUCTION ACCESS 4EJ Cp KEY MAP GHD Consulting Services Inc. 0 300' 600' , 222 South Church Street, Suite 400 Charlotte NC 28202 USA T 1 704 302 4910 W www.ghd.com CHARLOTTE CHARLOTTE WATER WJ)TER CHARLOTTE NORTH CAROLINA • ® 7030700047-17-503 Job No. File No. STEVENS CREEK Scales PLAN 1"=300' TRUNK SEWER PHASE l Know what's below. PROFILE Call before you dig. Hor• NTS KEY MAP Vert. NTS As Built Date A 2/16 TED FINAL DESIGNSheet Of L. ASSOC JEM TED MEB 5/1/18 3 26 No. Dote By Revision Surveyed By Designed By Drown By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT a - a j _ \ T✓ \ / \ PROPOSED STEVENS - - - - `V____ PROPOSED STEVENS _ �� - — - / - 100 YR FLOODPLAIN _ _ _ - ���\\ \ \ \\\ CREEK NATURE - - - CREEK TOB BY OTHERS I / ` ' - 7 \ a • • - � � a • � � `� � ( ) _ HAZARD AREA (TYP) \ I �\\\ ��� PRESERVE PEDESTRIAN 'BRIDGE (BY OTHERS) D #19524101MECKLENBURG COUNTY DB 12412 PG 394 EXISTING \ i000 STjVENS CREEK i • • • • • a 1 • , J ` -= woman_� 1 / ` �Z� ' TEMPORARY CONSTRUCTION\ I + - - PID #19514101 / / / / / EASEMENT (TYP) \ MECKLENBURG COUNTY 50' WETLAND BUFFER / �� / • • r i i DB 30459 PG 495 PERMANENT SEWER \ EASEMENT (TYP) • • • • • • • - - ! _ - - TEMPORARY ROCK \ 1 / - - - SEDIMENT DAM ` l WEIR = 4' \ • • • • • • i _ / 1cE TCE TYPE B (TYP) \ ICE T A O EXISTING MANHOLE i ' ICE T E \ STONE CHECK DAM TYP INTERCONNECTION _ / - - - TCE PsuE r E 10 (TYP) - pSUE \ SEE DETAIL SHEET 24 • • a (SEE DETAIL DWG 20)/ / / _ i / / — TC TcE BH -1 PsuE r E rcE OUTLET (TYP)ED STABILIZATION , _�` \ Muumuu — _ ICE —ICE - PSUE p3+00 A4 rcE4so -SEE DETAIL SHEET 25 \ SILT FENCE (TYP)�_ - _ _ ICE — –+00 — — 20' Pg UE — TCE = 3CE \ ^ \ SEE DETAIL SHEET 23 - - - ` Q ICE AZ+00 rcE \ \ TEMP. DIVERSION DITCH (TYP) Q ?SUE � - T - !� - - - - -� 4415+ TCE \ EE DETAIL SHEET 25 N8 , 5 N/ PE — — — —E — 0 g 43 5 �� _ - - _� 20' O UE TCE i Al+00/ g37.83� ITARY SEWER SUE �_ _ _-PS S - - l N66 �3�49"�y / P\E ce TCE • • • • ,,G, 24" SANITA TEMPORARY ROCK SILT_ _' — _ = = _ - - �� �°ROpOS •321.72• \ _6+ 00 rcE - - - - J / PROPOSE / CHECK TYPE B - _ - r ED 24p 00 \ Psu TcE LIJ A0+00 / ii ' SEE DETAIL SHEET 25 % i ' - - - ' _ Ems- - SAN�JrAl PERMANENT SEWER / / \ Psu �� rcE _ _ `7J EASEMENT(TYP)/ / A7+00 T , / / STA. A3+37.83 Q PrcE�o TEMPORARY SILT PID #19514101 suPROPOSED 5 NO3DITCH (TYP) MECKLENBURG COUNTY 4gbW rcE _J rcE / TEMPORARY SILT CHEC TYPE B iii / /i / D/A. MANHOLE MH -02 DB 30459 PG 495 PSUE Op •32¢99, A8+00 P �� ( \ LLJ W/ SILT BASIN TYPE B - _ OSEO 24b A �, v SEE DETAIL St'ET 25 /� / \ _ / / / / W/VENTED S TAR SE (� FRAME &COVER — — — PSUE wER As Q / /� / / --- =r— STA. Ao+oo 00000w- iPSUE - — — — — — _ — —PROPOSED 5' - STA. A6+59.55 ' ��— DIA. MANHOLE MH -01 , — ' — PROPOSED 5 \ - -- SUE D/A. MANHOLE MH -03 — — � Ss (BY OTHERS) _ — — / W/VENTED - — _ — -640-\PROPOSED STEVENS CREEK \_ 200' BUFFER LINE FRAME &COVER __— — — NATURE TRAIL (BY OTHERS) i SS Ssy_ SS�� /� PROPOSEDTORMWATER POND - - - / SS // - S& OUTFALL( BY ) 640- _OTHERS - - _ - - — // PROPOSED SANITARY- /�'� SEWER (BY OTHERS)�� / ----- ----- ���/ / _ _/--_---- --- PROPOSED STEVENS CREEK PUMP STATION (BY OTHERS)/�� / - -- ----- ----�/ jz -_� / _-_- _ ------------- -- _ A 2/16 TED No. Dote By woman Know what's below. Call before you dig. FINAL DESI Revision GHD Consulting Services Inc. 0 40' 80' , 222 South Church Street, Suite 400 Charlotte NC 28202 USA T 1 704 302 4910 W www.ghd.com CHARLOTTE CHARLOTTE WATER W6TER CHARLOTTE, NORTH CAROLINA 7030700-503 STEVENS CREEK Jobb No. No. File No. Scales PLAN 1" = 40' TRUNK SEWER PHASE l PROFILE Hor. 1" = 40' Vert. 1" = 4' PLAN AND PROFILE STA AO+00 TO STA A9+00 As Built Date Sheet Of L. ASSOC JEM TED MEB5 3! 18 4 26 Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT W J = W W to U)M o II ��� � +1W (0 Q = W ^- +IW WcMotn Q o o Z II �1� 3 W Az-^ v Ct o N ^ (0 11 C) IEXISTING Q _ m 640 64 O O +LO Q Qz U) W I W z= W C) Lj_j_ AT CENTERLINE (APPROX.) 6501 100 HAZARD YR FL AREA OD LAIN (TYP) 63C MIN. COVER 3.0' 4 P. SANITARY PROP. o ®0.20/ 24 D. I. SEWER [-- Cn __ / - - - \\ / � XIS NG BOTTOM STEVENS (APPROX.) // ♦ - \\ _ -♦ % �� CREEK PROP. 24" PVC SANITARY SEWER PROP. 24" PVC SANITARY SEWER 62C 6 0 ♦� PROP. 24 " PVC SANI TARY SEWER PROP. IN = 618.63 ®0.20% ®0.20% PROP. IN = 6 1 7.98 ®0.20% PROP. IN = 617.31 PROP. OUT = 617.9 8 PROP. OUT = 618.63 PROP. f OUT = XXX.XX (BY OTHERS) EXISTING MAN OLE NTERCONNECTION (SEE DETAIL DWG 20) E[ 0 p (_j a - a j _ \ T✓ \ / \ PROPOSED STEVENS - - - - `V____ PROPOSED STEVENS _ �� - — - / - 100 YR FLOODPLAIN _ _ _ - ���\\ \ \ \\\ CREEK NATURE - - - CREEK TOB BY OTHERS I / ` ' - 7 \ a • • - � � a • � � `� � ( ) _ HAZARD AREA (TYP) \ I �\\\ ��� PRESERVE PEDESTRIAN 'BRIDGE (BY OTHERS) D #19524101MECKLENBURG COUNTY DB 12412 PG 394 EXISTING \ i000 STjVENS CREEK i • • • • • a 1 • , J ` -= woman_� 1 / ` �Z� ' TEMPORARY CONSTRUCTION\ I + - - PID #19514101 / / / / / EASEMENT (TYP) \ MECKLENBURG COUNTY 50' WETLAND BUFFER / �� / • • r i i DB 30459 PG 495 PERMANENT SEWER \ EASEMENT (TYP) • • • • • • • - - ! _ - - TEMPORARY ROCK \ 1 / - - - SEDIMENT DAM ` l WEIR = 4' \ • • • • • • i _ / 1cE TCE TYPE B (TYP) \ ICE T A O EXISTING MANHOLE i ' ICE T E \ STONE CHECK DAM TYP INTERCONNECTION _ / - - - TCE PsuE r E 10 (TYP) - pSUE \ SEE DETAIL SHEET 24 • • a (SEE DETAIL DWG 20)/ / / _ i / / — TC TcE BH -1 PsuE r E rcE OUTLET (TYP)ED STABILIZATION , _�` \ Muumuu — _ ICE —ICE - PSUE p3+00 A4 rcE4so -SEE DETAIL SHEET 25 \ SILT FENCE (TYP)�_ - _ _ ICE — –+00 — — 20' Pg UE — TCE = 3CE \ ^ \ SEE DETAIL SHEET 23 - - - ` Q ICE AZ+00 rcE \ \ TEMP. DIVERSION DITCH (TYP) Q ?SUE � - T - !� - - - - -� 4415+ TCE \ EE DETAIL SHEET 25 N8 , 5 N/ PE — — — —E — 0 g 43 5 �� _ - - _� 20' O UE TCE i Al+00/ g37.83� ITARY SEWER SUE �_ _ _-PS S - - l N66 �3�49"�y / P\E ce TCE • • • • ,,G, 24" SANITA TEMPORARY ROCK SILT_ _' — _ = = _ - - �� �°ROpOS •321.72• \ _6+ 00 rcE - - - - J / PROPOSE / CHECK TYPE B - _ - r ED 24p 00 \ Psu TcE LIJ A0+00 / ii ' SEE DETAIL SHEET 25 % i ' - - - ' _ Ems- - SAN�JrAl PERMANENT SEWER / / \ Psu �� rcE _ _ `7J EASEMENT(TYP)/ / A7+00 T , / / STA. A3+37.83 Q PrcE�o TEMPORARY SILT PID #19514101 suPROPOSED 5 NO3DITCH (TYP) MECKLENBURG COUNTY 4gbW rcE _J rcE / TEMPORARY SILT CHEC TYPE B iii / /i / D/A. MANHOLE MH -02 DB 30459 PG 495 PSUE Op •32¢99, A8+00 P �� ( \ LLJ W/ SILT BASIN TYPE B - _ OSEO 24b A �, v SEE DETAIL St'ET 25 /� / \ _ / / / / W/VENTED S TAR SE (� FRAME &COVER — — — PSUE wER As Q / /� / / --- =r— STA. Ao+oo 00000w- iPSUE - — — — — — _ — —PROPOSED 5' - STA. A6+59.55 ' ��— DIA. MANHOLE MH -01 , — ' — PROPOSED 5 \ - -- SUE D/A. MANHOLE MH -03 — — � Ss (BY OTHERS) _ — — / W/VENTED - — _ — -640-\PROPOSED STEVENS CREEK \_ 200' BUFFER LINE FRAME &COVER __— — — NATURE TRAIL (BY OTHERS) i SS Ssy_ SS�� /� PROPOSEDTORMWATER POND - - - / SS // - S& OUTFALL( BY ) 640- _OTHERS - - _ - - — // PROPOSED SANITARY- /�'� SEWER (BY OTHERS)�� / ----- ----- ���/ / _ _/--_---- --- PROPOSED STEVENS CREEK PUMP STATION (BY OTHERS)/�� / - -- ----- ----�/ jz -_� / _-_- _ ------------- -- _ A 2/16 TED No. Dote By woman Know what's below. Call before you dig. FINAL DESI Revision GHD Consulting Services Inc. 0 40' 80' , 222 South Church Street, Suite 400 Charlotte NC 28202 USA T 1 704 302 4910 W www.ghd.com CHARLOTTE CHARLOTTE WATER W6TER CHARLOTTE, NORTH CAROLINA 7030700-503 STEVENS CREEK Jobb No. No. File No. Scales PLAN 1" = 40' TRUNK SEWER PHASE l PROFILE Hor. 1" = 40' Vert. 1" = 4' PLAN AND PROFILE STA AO+00 TO STA A9+00 As Built Date Sheet Of L. ASSOC JEM TED MEB5 3! 18 4 26 Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT W J —43 41 W J I� �p O M O co N OVM �CN Q �I4 p I MIO OO M Qc0 Q�p� II QQ o II \ �n��3� 4 1 1 1 1 6irk I0 CROSSING ti O XISIING AT CENTERLINE GRADE (APPROX.) O O 00 Q z MATTING HEET 25 Q z 100 YR HAZARD FL AREA ODPLAI (TYP) EROSION CONTROL DETAIL ( I EE 3 U) w Cl) W EXISTING S VENS 0 LLJ w REEK BOTTOM APP OX.)-- w w z= cn -- - -- -- - -- -- - -- - -- - -- -- - - -- -- - _ __ -- - cn W W - -- - -- -- - -- -- - . \� __ ` -- -� �� -' ��� y IN. COVER .0' '- -- -- _ __ U W - - -- -- - -- `` Q PROP. 24" D.I.P. SANITARY SE►NE Q 4_1 PROP. 24" PVC SANITARY SEWER PROP. 24" PVC SS PROP. 24" PVC SANITARY SEWER ®0.50 o ®0.50 2 PROP. PROP IN OUT = X621.52 = 620 PROP. IN = 622.17(6") 621 52 ®0.20' ®0.20% PROP. IN = 619.28 PROP. IN = 619.92 P. OUT = 619.28 PROP. OUT = 619.92 10+0 11+0 12+0 13+0 14+® 15+0 16+0 17+0 18+0 � -_ -� w / I � `" _ /.\� ��� - - -� --- - \= = //\\- / ` PID #19524101 x \ WROPOSE SI�VENS\�\ _ _ _ _ - _ _ _ _ _ MECKLENBURG COUNTY__ CREEK TOB (BY OTHERS)_ - 6 — - r --� - j - �� -�� _ \ DB 12412 PG 394 - � Ji EXISTING STEVENS CREEK \ PID 19524101 MECKLENBURG COUNTY ( ' / \ �� _ k I J ` STA. A 13+07.73 \ \ ` \ \% DB 12412 PG 394 ' _-� _ �✓ \ /� k \ _ PROPOSED 5'/;\\\\-,I I - \ D/A. MANHOLE MH -05_ / // t \ I - / ♦ ... // _ ` I i x \ y / W/WATER TIGHT _ ///� �� /� �� �� �' / _ \ ' TEMPORARY ROCK FRAME & COVER _ , ; SEDIMENT DAM �� \ \ \ - / / /TEMPORARY l \ -�/ J IJl ' —moo* ' ONSTRUC—■ TION '/' WEIR = 12' \\ \\ \ \' / EASEMENT (TYP) \ TYPE B (TYP) \ \ / �, I _ / _ TCE � CE \\ \ ter/ ICE \ \ \ \ TICE SEWER TEMP. DIVERSION DITCH (TYP) I ICE PSU �\ PERMANEN� \ Ice rcF \� EASEMENT (7Y ICE \ \ SEE IL SHEET 25 owns- / - - - \ ?SUE ICE +00 roe � \ - SILT FENCE (TYP) p13 ICE_ cF SEE DETAIL SHEET 23 - Psu i _ ' 1 ICE ?SUE _ - \ REINFORCED STABILIZATION' Al2+p0 \ q' l r�F \ OUTLET (�) �• ICE TCE _ _ ICE ' PsuE _ �W �' - - - _ _ 4f00 rcE \ SEE DETAIL SHEET 25Cn N66'03'49� Pa °?su� 1. N384 rcF _ +0 _ \ ICE ICE�� Al 0 24 3 SANITARY SEWER PSUE T ° ,`• I T _ PROpOs 4 �9 06� bH' PSUE rc� \rcF TCE p UE n _ , rcE D � P I 20 - - - _ \ E PROPOSED T A 1500 Sq'"'�TgRY — _ rc ��\ v lJ , SEER �\ �i� 6 ' 1 PSUE f�\ — — — _ SE-y,E. "SUE ro �c — R - - \ - \ k00 ��a, Ito SAI I / V 2� 1 •03'49"W p0 N66 g9, 4. 20' PSUE SEW ER - - - - \ _ - 100 YR FLOODPLAIN - - - - Ers / / - _ - - - -HAZARD AREA (TYP) _ TEMPORARY SILT \ \ DITCH (TYP) '4 i16,�00 - \ / Ep PROPOS % V , SANITARY psuE - / \ 24" -` \\ PERMANENT SE R / / PROPOSED STREAM RESTORATION T�MPORARY SILT CHECK TYPE B \ \ �F�, O • • PROPOSE PR PsuE \\ \ / STAGING AREA _ \ \ \ EASEMENT (TYP) \ I W/ SILT BASIN TYPE B \ \ �\CP SEE DETAIL SHEET 25 ' \`Ao\ 0 %C STA. A9+84.54 - l / ' ` \ \ \ _ ____ ' r PROPOSED 5' - ' \ / (, \ \\ \ TEMPORARY STREAM i I _1__--\ \ / _ -PRO-POSED ACCESS ROAD STA. A 16+26.79 � \ \ \ CROSSING (TYP) D/A. MANHOLE MH -04 \ I - - - N \ _ _ _ \ \ \ \ \ \� SEE DETAIL SHEET 23 (BY OTHERS) PROPOSED 5 40\ _ \ /�" ' O O W/VENTED - / \ - _ - - �� - - - - PID #19524101 - \ D/A. MANHOLE MH -06 \ \ _ \ \ \\ \\`' ;� \\ - - \\\\ TEMPORARY EROSION / \� CONTROL MATTING (TYP) � FRAME & COVER , _ _ _ �\ -MECKLENBURG COUNTY \ \ \ m DB 12412 PG 394 W/WATER TIGHT ` \ \ _ \\ SEE DETAIL SHEETZ,5 - \\\ ` _ \ — _ GHD Consulting Services Inc. - - - FRAME & COVER \ \\ - " _ _ \\ _,�\\\\ - �� 0 40� 80� 222 South Church Street, Suite 400 , PID #19514101 MECKLENBURG COUNTY - \ DB 30459 PG 495 111(\ \ \ _ _ _ - - - _ _ _ - _ NATURE PRESERVE \ / \ \/ \ I \ I N 6' SS CONNECTION \ / - - \ �' SEE SHEET C302 - - _ _ _ ---- \`\\ _ \\ \ \\� / _ arlotte NC 28202 USA Th1 704 302 4910 W www.ghd.com ---__-_ --_\ \,� - � IIII-\\ �- \ \\\ \_ _��-- _- / \ \ V _-- -- -- _ 200 BUFFER LINE \------- �_- \�~� -_ ------ \\ 50' WETLAND BUFFER__- \���\� -� \; ;�\___^ CHARLOTTE CHARLOTTE WATER ---------------- ------------ —\\\\ \_ --_� �\ \ \ \\- - \\__ W6TER CHARLOTTE, NORTH CAROLINA `\\ \\\ ' -----'—\_--'— ----- \ r \( / '— _ \\ `----' \— 1 , \ I\(l sso� \\-\_------- --\ _--__�'—� \\— \\ _ -\ \� \ • 0 7030700047-17-503 STEVENS CREEK Job No. File No. / --- ----------------- \ \\ \ Scales PLAN 1„ - 40' TRUNK SEWER PHASE l Know what's below. PROFILE ------------- — _ \N \ Hor. 1„ - 40' Call be fore you dig. PLAN AND PROFILE Vert. STA A9+00 TO STA A 18+00 \\\\ \\\\\ As Built Date ___`------\sss\\\\\ \\\ A 2/16. / TED Sheet Of FINAL DESIGN L. ASSOC JEM TED MEB 5/1 18 5 26 __/\_—_ - - - - - _ \ \ \ \ \ \ \ - / \ No. Date By Revision Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT W J ++ IQ O Q�p� II QCc _ NK 4 00 YR FLOODPLAIN Et Cc 4 AZARD AREA (TYP) O EXIS NG AT CENTERLINE GRADE (APPROX.) O __0 O O Q O N Z EXISiI CREEK G S BOTTOM NS (APPROX.) z � U7 W W 3 , MIN. COVER 3.0' /� -' 3 60 �� - -- = LiJ ®0.50% 4 „ D. I. P. SS PROP. LLJ = �� 24 PVC SANITARY SEWER w U PROP. 24" D.I.P. SANITARY W U (n SEWER Q ®0.50 0 Q ®0.50% PROP. IN = 623.57 PROP. OUT = 623.57 PROP. 24" D.I.P. SANITARY SEWER ®0.50% ANTI -SEEP COLLAR SEE DETAIL SHEET 21 2 2 1 8 1 9+ O+ 1+ 2+ 3+ 4 777 N \��\�� NOTES: 1. CONTRACTOR SHALL PROVIDE AND —\��=_ --- ---- �\ —\ \ \ \ \ \ I I �\\J 1\I�`>ll / PLANT 9 GALLON SIZED EVERGREEN — — — — — TREES, THREE (3) PER LOCATION ALONG PERMANENT EASEMENT LINE \� AT MANHOLE #7, 8, AND 21. � � \ I \ \ \ \ PID #19524101 \ I \ \ \ _ r / MECKLENBURG COUNTY I \,��yl _---•/� / ��\� \\'- \ \\ \\\\ \\ \\ / DB 122 PG 394 �� PROPOSED STEVENS CREEK TOB (BY OTHERS I \ J HAZARD AREA (TYPy 100 YR FLOODPLAIN// e1111.111, EXISTING STEVENS0 y/�/ 00 -CREEK / \ 0 / I n + \ �_���_� ; j \ \ \ TEMPORARY EROSION /"CON \ \ \ �, ` ���\ CONTROL MATTING Ct ONTRACT - �� `--\-\\ \ \ -SEE DETAIL 25 + REMOVE AND REPLACE 3 r- Q O s \ TEMPORARY = _-_-_ _ - - TRAND ELECTRIC WIRE � ` r - f \\� ���� �\ + NCE TO OUTSIDE LIMITS 1 CONSTRUCTION �� ti\ \ �� \� �� \ F TEMPORARY EASEMENT Q O z EASEMENT (TYP) IL ENCE (TYP) REORCED STABILIZATION �a - + �[\ - -(SEE DETAIL SHEET 26 DETAIL SHEET 23 \ %\ \ \ �% z Q PERMANENT SEWER ` ,OUTLET (NP) \ \ - _ - - FOR FENCE REPLACEMENT EASEMENT (TYP) \ .\_� - - SEE`DETAIL SHEET 2 c �� = 635 = %� - / \/ -�� Q CIO LLI/ \ \ � � � � \ � -� - L- �� �-� � /� � - - E CE TCE (n LTJ W T6E TCE TCE TCE TCE TCE CE - CE \ E E + C W = _ _ _FCE T Tc _ E` X - - - - - - - - PSUE Li z V J PSUE - SUE PS P E r X ,. ` ` I z V l J W 20' � A20+00 � X A23+00 A2 00 A19+00 I A22+00 I N76'2658 "W A21 +00 N78'30'38 "W — J L d U LTJ BH -2 20' 41 f.48' I 444.99 SEWER = W U (� PROPOSED 24" SAN/TAY SEWER �PRO�SED 24" SANITARY x - --- --- PSU P UE PS uE PSU P / _ \ ANTI -SEEP COLLAR _ i \ \� - PERMANENT SEWER FARM GA i/ / • (FODETAIL => SEE DETAIL SHEET 21 a \ \ \ \ EASEMENT (TYP) SEER SHEET 26) i SEE NOTE 1 STA. A20+38.27 PROPOSED 5' t / ` GHD Consulting Services Inc. , • • • REDUCE CLEARING TO 40' I D/A. MANHOLE MH -07 ! / / 0 40' 80' 222 South Church Street, Suite 400 , Charlotte NC 28202 USA _ I STA A19+20 TO STA A20+20 W1 WA TERT/GHT T 1 704 302 4910 W www.ghd.com �,�._ _ _ _ FRAME & COVER / / PID #19524101 /� 50' WETLAND BUFFER \ LI / 1 PID #19517155 / / / < MECKLENBURG COUNTY / / CHARLOTTE CHARLOTTE WATER / JAMES R WIGGINS JR / / DB 12412 PG 394 \ _ _ - & MITZI C WIGGINS i / / �/ i / / � - DB 8064 PG 520 � / � � W6T E R � MB 26 PG 552 / ,' f CHARLOTTE, NORTH CAROLINA �— / \ 200' BUFFER LINE / /�. �' - / /'�, `' i / / / / / —�� • 7030700047-17-503 STEVENS CREEK Job No. File No. Scales TRUNK SEWER PHASE I /� PLAN 1" - 40' �-\ i • a i i i I I� /// / ./ -/ /� _ Know what's below PROFILE � Hor. 1„ = 40' // //,/ /�/ \ / Call before you dig. vert. ," - 4' PLAN AND PROF/LE STA A 18+00 TO STA A24+00 As Built Date A 2/16. TED FINAL DESIGNSheet L. ASSOC JEM TED MEB 5/1/18 6 Of 26 No. Date By Revision Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT W J � W J O � M= M otr) � V O N W LQ �0 Q cMo Q Q p II _EXISTING QI022 � W II GRADE W oX (/� 3 AT CENTERLINE (APPROX.) 5 5 MoIQ ,QN o CIO+ oZ _ o +o IW ��� O O 1o°�OW 00 Nt co QQ oo II L Q O I _ Z II ��3Q CROSS NG #2--Q z z 100 HAZARD YR FLOODPLAIN AREA (TYP) Q 640 LLJ 6412 W = ___----_-. .---__- W = z Cf) W I EROSION SEE DETAIL CONTROL SHEET MATTING 25 (TYP) -LS S CREEK BOTTOM (APPROX.) - - "J - z W _ __ __ _ __ __ _ __ __ .,� ^ "' - � �� - W"" _ -� - -- -- - -- _ - = W Cn Q PROP. 16 " p, I.P. SANITARY_ 00.60 Q � -- - -- -- - -- -- - •, � SEWER � p p, 16 " D.I.P. SANITARY 1N-4FOR 310'O 3 PROP. IN 631.44 3 6PROP. 1" p, �, P. SANITARY PROP®0.60 SEWER- 0 1= OUT = 631.24 ANTI -SEEP COLLAR SEE DETAIL SHEET 21 7-;; 7-1 777 17.1 2 / L - 4 ®0.609' PROP. F /N = 628.71(12") AA/)i IPROP. IN = 628.96 PROP. OUT = 628.51 PROP. C IN = 626.55(12")- 26.55(12")PROP. IN=1 626.80(16 ") --PROP. I I I PROP. , f , OUT i = 625.80 PROP. 24" D.I.P. SS ®0.50% 4 5+ 6+ 7+ 8+ 9+ O+ 1+ 2+ 3+ 4+ 3 5 000, NOTES: 1. CONTRACTOR SHALL PROVIDE AND —� \ I / I \ \ \ \ — / \ ) / / / / / / / / / / N, PLANT 9 GALLON SIZED EVERGREEN TREES, THREE (3) PER LOCATION ALONG PERMANENT EASEMENT LINE AT MANHOLE #7, 8, AND 21. —655CD PWOOOOO 0 9 ` I 1 21 660 PID #19524101 MECKLENBURG COUNTY / / / \ \ — _ \ \\ / / Q \\ \\\ \ \ \ \ \ \ ��"� \ iso \ \ ,. \ \ DB 12412 PG 394 / ` \ — _ — — \ / — — _ — ' ) \ l \ 1 \ \ \ \ \\ -- \ \ \-- _\ //// / /// O G� Cj� / illllll\ EXISTING \ \ STEVENS CR I I \ \ I I I I \ \ \ \ \ — —_ _ — ' ' \ , 1 1 1I EROSION CONTROL MATTING (TYP) _ _ i" —650- — — / I ( \ \ \ SEE DETAIL SHEET 25 \\ —\\\\\�' STA. A32+32.51 \ \ \ ✓ / / / / / — — — / X X �� llllh x � \ \ \ \ `\ \ \ \ \ ` _ STA. A28+10.33 _ _ _ - / \ � \ .�00 BUFFER LINE I \ ' _ _ __ l j J / � I ` � � /00 PROPOSED 4 / 50 WETLAND U IIII Jill TEMPORARY EROSI \ \ \ \ \ \ \ \ \ _ \ PROPOSED 4 \ \ _ _ - _ - \ / / I \ sA \ I IIIII CONTROL MATTING (TYP.) \ \ S�E D TAI HEET 25 ` \ \ s\ \ 1 \ \ 1 \ PERMANENT SEWER DIA. MANHOLE MH -10 - - - DIA. MANHOLE MH -09 _ — \ \ EASEMENT (TYP) \ 655— \ W/VENTED + ANTI -SEEP COLLAR II f I / \ \ l \ \ \ \ \ I \ 1 ' —ARY ` \ \ \ W/VENTED \ \ \ ` FRAME & COVER FRAME & COVER - \ \ \ \\ ` - O SEE DETAIL SHEET 21 — _ / / \ \ \ \ \ \ \ O m + \ \ / ' I FORD CROSSING \ \ gg \ SEE TIL E T 23 - \ \ \ BH -4 / — — — \ \ \ \ — _ PsuE PsuE / — UE \ I Y \ \ / ` � REINFORCED'iTABILIZATION BH 3 PsuE PsuE Ps A32+00 15 suE � A30+00 -A31+00 S40'36 36 W / / — � PSUE — - 650 - — / j \ SLI s -b / \\ \\ // / / OUTLET TYP PSU; AIL SHEET A28+00 A29+00 _ � 422.18' — --1-59 1-5' — i / _ — — — _ _ � A33+Q0) _ — \l = 'app \ 1 �O 7T W \ \ 11 I I 0 oN o� i IIIII DE 25 15 / — R / +OO . ' 1 "W ' / A27 S35 37 3 CO+00 _ _ — PSU / //\ -� PROPOSED 16" SANITARY SEWER r ^ \ PSUE — PSE _ �♦ SUE \ P \ — — — — —, —_ P �� / x A34+00 PID #19517155 \ Psu \ — / \ �o ' �� so ` 327.07 �5 \ — / �A25+00 E JAMES R WIGGINS JR \ & MITZI C WIGGINS `\ �\ N s� \ �N A26+00 _ pROpOSED 16" SS PSUE \ 1 PSUE \ _PsuE / \ X PsuE IW / SLI / / / T / SO \ E TCE ���_ T� ' T A3 PROpOSE.� DB 8064 PG 520 \ MB 26 PG; 98\/T \ \ N x` \ 20, \ UE I \ \ _ — _ / / P �s51F TCE TCE - / CE TCE TCE \ _ — — — — — TCE / T \� ------ \ /TCE�\\. — \ uy\ —�\ // REDUCE CLEARING TO 40' STA A24+00 TO TA A25+ 5 \ SEE NOTE / PsuE\ ✓ , ��/ — Xoo T TCE \ — — \ 1� 20 6P' �C�\�\\� T \ \\ \ �rcE c STA. A24+83.26 1 a a \\ ��\ 1 \\y — �\ \ �— \ \ ' /� _ PERMANENT SEWER is45r� �"► TEMPORARY ROCK (TYP) EASEMENT TYP = STA 80+00 ' PROPOSED 5 q �`� \ N a� \ L \ \�\\ \ \\ \ I \ A GATE \ \ _\ m (FOR DETAIL v �� PERMANENT SEE SHEET 26 � � NT SEWER T / _ `SEDIMENT DAM \ \ ) ' �S ' ' / WEIR = 4'000 SILT FENCE (TYP) / / TYPE B TYP \\ \ x / ( �� / \ /� �� — / t * \\• T TYP -� D/A. MANHOLE MH -08\ ANTI -SEEP COLLAR ( ) \ fi x SEE DETAIL SHEET 21 v TEMPORARY / m W WATERT/GHT CONSTRUCTION �1T12A TOR SHALL REMOVE AN EASEMENT TYP FRAME &COVER / \ REPLACE 3 STRAND ELECTRIC WIRE ( ) I / ,, \ �_ �� SEE DETAI SHEET 23 v _ _ e / /� // TEMPORARY \,\ _ C 1 +00 `= ' �' / CONSTRUCTION \\��\\ / \ �\� \ /o i TEMPORARY \\\ EASEMENT (TYP) \� \` —�; \ \ // EXISTING SEDIMENT DAM \\� _ _ j STEVENS CREEK 7 \ f o ( \ �� _ iF \ _ // / WEIR = 6' ®\ —���—\ ) ' ��j/// / /,� _ ��` ���� �� _�� l j/ 'N /� l/ — ` TYPE B (TYP) \Z 0 40' 80' m FENCE TO OUTSIDE LIMITS OF����� \ MPORARY STREAM \ \ • a X / ? r' TEMPORARY EASEMENT (SEE DETAIL � 1 I \ O \ � CROSSING(TYP)\�' w �i�if 100 YR FLOODPLAIN / ��� JJ — �\ �/ // J HAZARD AREA TYP-1 �� ( ) f / i " �� — �//moi \ PROPOSED STEVENS --- y /�/// / — \ /// /^� \ l l / / STONE CHECK DAM (TYP) \� SEE AIL SHEET 24 \ \ \ \ -o O 1\ \ A \ •\ • / p NSF SHEET 26 FOR FENCE REPLACEMENT) (S DETAI SHEET 23 w _ �� / \ --�� DE \ \� � — ,, — _ / // �\ CREEK TOB (BY OTHERS) — /� �� / //// / r - r\\ //�/i / \ _ �_ _ _— J TEMP. DIVERSION DITCH (TYP) ^\\ FENCE REPLACEMENT /" I I/�j r� — —_ \ _ �� �/ / / / _' y _ �F �� __, — / SEE DETAIL SHEET 25 \ LOCATI N l \ r � /�l —.� �'` �\ I� � / \ \�� i �� \ \ GHD Consulting Services Inc. 9 222 South Church Street, Suite 400 1 Charlotte NC 28202 USA \ \ \ REINFORCED STA IL A 014- n OUTLET (TYP) ; \ `\\ _ / — — / X / / Z — S S — ' — — — — T 1 704 302 4910 W www.ghd.com \ \ • r' \ SEE DETAIL SHEET 25 — SHEET 15 X \ - JJ �;� Sg — PROFILE \ \ ► - - �,� x \ , 0 r r \ \ XIS I ING STEVENS / /,, — — _ _ _ _ � EXISTING � CHARLOTTE CHARLOTTE WATER \ \ \ • • c^� EXISTING WWTP \�\CI�EEKTR,)BUTARY/// � I — / / ��// /. PUMP STATION ;� MANHOLE +00_ _ // � � � _ \ SANITARY SEWER m _- W�T E R CHARLOTTE, NORTH CAROLINA • EXISIING FENCE TO BE REMOVED — TEMPORARY EROSION - e�X // AND REPLACED BY CONTRACTOR \ / -CONTROL MATTING (TYP.) / � X„ /� I {TYP) SEE DETAIL SHEET 21 / � SEE DETAIL SHEET 25 - • 7030700047-17-503 \ , \ X� �X �' S - - - - - QBE \\/�/ ' — Job No. File No. Scales STEVENS CREEK \ I SEE NOTE 1 I x 10 / /� �// / SS ��/ _ _ \ I _ , _ _ , _ _ - - _ - _ AN I — \ _ / PID #19517132 PID #19517133 PLAN 1 " = 40 TRUNK SEWER PHASE l a 30� ti PID #19517148 m / I //\ I / \ \ / -DEAN G HAWKINS & ' MICHAEL BRADLEY LITTLE — — — \ / KELLIE P HAWKINS _ & NOREEN A LITTLE \ Know what's below. PROFILE 1" = 40' Hor. \ \ \ . / MECKLENBURG COUNTY S ( ►� a - k / m S I DB 24274 PG 101 DB 8702 PG 72 — — — _ _ I I • a �/� I DB 24891 PG 862 �/ 1 \ I \ \ / LOT 32 — LOT 33 EXISTING WWTP Q lF C\5 \ I h \ / MB 22 PG 303 _ MB 22 PG 303 \ ` - Call before you dig. - g Vert. 1" 4' STA PLAN AND PROF/LE A24+00 TO STA A35+00 m PID #19517147 I CITY OF CHARLOTTE 30613 PG 431 J / — TCF / \ \ / _ _ I � � \, As Built Date Sheet Of _DB � _ - -- A 2/16 TED FINAL DESIGN L. ASSOC JEM TED MEB 5/1/18 �G No. Date By Revision Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT W J � = W ON +I W W two 6 6 J N_= BIZ W^ z Qp^Z II oo o°.��, +IW C�t�o ������ O �Q 0 Q N� o 0 + Q O +Q MQj 'Ilk Qom to Q to II I (nQ_ I EXISTING GRADE AT CENTERLINE (APPROX.) + 0-) -Q O Q LIJ 100 HAZARD YR FLOODPLAIN AREA (TYP)__17 (� W 5 S W W W = W = Un __zUn = W (APPROX.) = W IN. CO R 3 0' EXI CREEK TIN SIEVE BOTTOM NS U (%� _ _ ` U (W -- -- i 640 16" PVC SANITARY SEWER PROP. PROP. 16" D.I.P. SANITARY SEWER ®0.60% PROP. f IN = 638.11 PROP. OUT = 637.91 01 PROP. IN = 635.57 ®0.60 PROP. OUT = 635.37 PROP. f IN ,= 633.37 PROP. OUT = 633.17 5 6+ 7+ 8+ 9+ O+ 1+ 2+ 3 O (/I I I/ I I I \ I \ \\— /' /' // // /l l � 5, —670 -' STA. A42+42.63 �/ PROPOSED 4' — DIA. MANHOLE MH 131 W/VENTED Q FRAME & COVER QST S 1 \ I I I I 1 'STA. A35+20.43 \ -- \\\ \\,\ ---_ ��, I\ I\ I\ I 1 PROPOSED 4 \\ ��_ —_,\ /C\\\ ---� tixo°/- ' P� \�\ ��—�/ ��' /,-- /� /// / / /'////' �( \ \ \ , D/A. MANHOLE MH -11 \ \ �. / /� S �p— eS e �� /� x 6> \\ \\ \ \ \ , — _ _ _ \ \ — — / / \ \ \ W/VENTED \ \\ \ \ / / /� \ \ _ — — — — 200' BUFFER UNE / // /' \ \ ---J , / / ' / / '09 S���R / �O PERMANENT SEWER �� \\ \ FRAME &COVER \\ \\ \ / /'� _-- --___—_ /// /��//�/// SZg•�a 20P�\�pR� �O �c�/ �EASEMENT(TYP) \ \ /I 00 \ \ \ \ \ \ \ \ \ \ \ \ \ / PID #19524101 — — _ \ \ — — — / / // / /'36'' \ \ \ \ \ ( _ _ — — — \ \ \ \ PERMANENT SEWER- _665- — MECKLENBURG COUNTY - - / / / Ses�� TEMPORARY �i CONSTRUCTION es k00 Q / EASEMENT (TYP) \ _ '- J DB 12412 PG 394 \ \ \ \ \ \ \EASEMENT (TYP) / — . — �_ _ / / / / \ \ ' / P OP O O O x \ \ \ \ \ ` STA. A38+53.42 U` \ g3gx00 \ \ \ ,' / PROPOSED 4 ' \ \ / \ \ D/A. MANHOLE MH -12 + X \ \ ps�F \ \ \ — _ / / /' , s \ \ , , \ / / / / W/WATER T/GHT — �•. ����—�' - �,r,- % V% \\ OSE,0\3rr 08•� \\\ ,\ '—'// FRAME &COVER okoo fs"V m� noun low= \ \\ S4iVj�, g3���\\�66p__ // / esu e—/ 30' BUFFER LINE ro /\`// ` F \ \ \ \ as�q�y S x00 / 15' — ` `/ - / J / ' -- 50FFER LIN x/jj�� % �, W �� — ` X / — c� /� PSLF \\\ '/BH �� SILT FENCE (TYP) W \\\ `\\ / /1—�/ _— -5 /� \\\\ \� r,��J \ \ p 1J _—_-655 i / S�� 15' 8x0 15 SEEA SH ET2 /\3 _ Py9 25 --- 0 '40PF— W\\ \\ \ \ PSU 20 �i/a /jam // / / LLJ7 U(J-)III `— \ CF \ - I X7%1 � \\"► \ STONE CHECK �TYP)' L / j / rc O / x \ \ \ J F j� ��a — �c� SEE �pc E EE / \ ` _ / F / I TEMP. DIVERSION DITC& TYP \— x \ \ �c� 1 EE ETAIL SHE T !�i %/,�%/ = EXISTING , //// — / STEVENS CREEK PID I #19517142 — — rCF / x — —� ��/� 11111\ I —I cF / RosA E MASCORRO & MERCEDES H MONTALVO DB 17117 PG 944 � GHD Consulting Services Inc. 222 South Church Street, Suite 400 I I xl , _ ��\\\�\\ �\ x ---// —'— \ LOT 42 d MB 22 PG 303 , Charlotte NC 28202 USA ROPO$ED STEVENS 1 ` � / I, - � CREEK TOB BY OTHERS J — — — // / / ( ) TEMPORARY ROCK \ J ® / — / / / � / / T 1 704 302 4910 W www.ghd.com SEDIMENT DAM/i//�/ ,' -WEIR = 6' J — — // j �?� _� // / \ / / CHARLOTTE CHARLOTTE WATER TYPE B TYPE %—�// (TYP) , �_ / - /' �, // / / \\�\\/�_,, 100 YR FLOODPLAIN HAZARD AREA (TYP) W6T E R CHARLOTTE, NORTH CAROLINA / ! — — \ \ PID #19517141 .0001 JAMES T BOYLES JR • 7030700047-17-503 _ SS \\ \ — \\\ �\\\ �\ // /////� I \ \ .� / / / \ Y & ROBIN W BOYLES DB 13846 4G 682 ® Job No. File No. STEVENS CREEK ss _ \' i\\� \ \\ \ \ // / ►; / �/////// / \� \\ S \ / / \ S / / MB 2j i 303 e / Scales PLAN 1" = 40' TRUNK SEWER PHASE l _ SS\, I \ -/ \ , /' / %/�//// / \ \\ S—� — — / Know what,s below. PROFILE Hor. 1„ - 40' ���� PID #19517138 PID #19517139 — — — — — — — _ =\� PAMELA SULLIVAN & DAVID L COLE & — S PID #19517140 `� - JERRY M MUSSELWHITE JR Call before you dig. = PLAN AND PROF/LE Vert. STA A35+00 TO STA A43+00 PID #19517136 — _ — / PID #19517137 / �'"r•\ — KENNETH AUBREY TYREE ' TERESA A COLE RONALD L PUTNAM JENNIFER BROWER DEGROAT — DB 7455 PG 271 \ — — DB 8838 PG 329 \ DB 8131 PG 67— — & SHERRI H MUSSELWHITE DB 9277 PG 598 As Built Date Sheet Of DB 8006 PG 291 — — — — _ LOT 36 LOT 37 LOT 38 — _ _ _ — LOT 39 — MB 22 PG 303_ / — — MB 22 PG 303 / / _ MB 22 PG 303 — — _ MB 22 PG 303 — LOT 40 A 2 16 TED MB 22 PG 303 � �� No. Date By FINAL DESIGN L. ASSOC JEM Revision Surveyed By Designed TED MEB 5/1/18 G By Drawn By Project-Engr Approved By Date 8 2 V A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT W J � Z O QO ,6 0 1360 O -O O EXISTING GRADE O LU AT CENTERLINE (APPROX.) S EAM —CROSSING 100 HAZARD YR FLOODPLAIN AREA (TYP) + O Q O Q p 22 Qz Qz wEROSION w w = U) w w _ w 5 ATTING SEE DETAIL CO (TYP) TR SHE L T 25 XI TIN CREEK S VENS BOTTOM APPROX. 5 z (� Li � ` = w w w v� IN. COVER 0' Cl) 16" PVC SANITARY SEWER PROP. PROP. 16" PVC SANITARY SEWER ®0.37.6 4 4 ®0.606 PROP. IN = 640.44 PROP. OUT = 640.24 EWER PROP. 16" PVC SANITARY SEWER -- @ ®0.60% PROP. 16" D.I.P. SANITARY SEWER ®0.60% 3 4+ 5+ 6+ 7+ 8+ 9 -1- 00000/ / l I -J///// �6e0. \\ PID #19524101 / / — 200' BUFFER UNEP i l / / EROSION CONTROL / / / I \ MECKLENBURG COUNTY \ \ DB 12412 PG 394 MATTING (TYP) SEE DETAIL SHEET 25 ` \STA. A45+99.11 PROPOSED 4' _ 1 \ D/A. MANHOLE MH 14 6�//�r��/���f/ _---___— �� pSUF W/VENTED ___ 670\\�\ q4 \ \ - 6* FRAME & COVER / PERMANENT SEWER / EASEMENT (TYP) — — — _ — psfi — \ \ --� P SU — — — — — � '. �_---_=665_--- 0 15 f Ps 447 _ — _ — _ _ — — — PID #19523106 \ \ ?SUE p44+0 \ '�00 ps _ — _ _ _ \ uF — _ _ _ � MECKLENBURG COUNTY \ — — - � �� _ _ DB 12412 PG 394 ' 6'37"W 15' ' 1ce ro �P S _ — \ 524' � ! / / Tce x v � \ 86. 00 356.49 SEWER PsuE sso\ 1 6" SANITARY UIP T�\ P� \ \ \ \ \ \4sr, pR0p05E0 PsuE �' E x MPORARY STREAM ` \' \ \ ps�Fs'4N/r q48 \ \ \ tc � CROSSING (TYP) _ — x t v � S X00 \ Fy'Fip Ice //® SEE DETAIL SHEET 23-=� x t� Cay 15 \ O \ — �' ICE ' --_--� \\\ \F — p F� \ � r n ^ 1 1cE _ _ TEMPORARY ROCK - - _ = Su SEDIMENT DAM =_ \\\\�\\ \r�F T npsuF PERMANENT SEWER WEIR = S' /iii\ ` \� \ \ ` �\ �� rcF - —— r�rl EASEMENT (TYP) / TYPE B (TYP) �(/ �_ �?��\� ` \\\\\ ; \ q4g _ / \ x /�/PROPOSED STEVENS O• %� CREEK TOB (BY OTHERS) k STONE CHECK D M (TYP)rc SEE DETAIL SHEET 24 EXISTING / x /�, \ / / STEVENS CREEK / /� r `� J /�' TEMP. DIVERSION DITCH (TYP) �a\\�� _ — �V SEE DETAIL SHEET 25 50' BUFFER LINE / �,\� / ^ 16 PO PO AR / a ` Z PORA YI // / / / 5 \/� v / I IL /\_ SEDIMENT DAM _ —5- # /,, CONSTRUCTION l /r//// / / / i 30' BUFFER LINE 1 / ` / / / ` WEIR = 10 ` // `-' ) O I, EASEMENT (TYP , /�r / / / i �/ — — TYPE 6 (TYP) � // �� � � �>"`jam l �I / Wwoo �\ ` \� l I/ // —// SILT FENCE (lYP) � EE DETAIL SHEET 23 r '6g O / / 100 YR FLOODPLAIN/l//llI I �\ �\ I / / j / I \ \ i / I 0 40' GHD Consulting Services Inc. 80' 222 South Church Street, Suite 400 , \ _ HAZARD AREA (1YP) // I // // I I\' \ / Th1 704 302 4910 W www.ghd.com CHARLOTTE CHARLOTTE WATER +� W6TER CHARLOTTE NORTH CAROLINA \ _ / ® 7030700047-17-503 STEVENS CREEK PID #19517143 PID #19517144 PID #19517145 ` Job No. File No. ROBIN C CARROLL & RONDA S AVILA / ALEX P LECLAIR & + WILLIAM M CARROLL � DB 23069 PG 139 SAUNDRA LECLAIR \ \ Scales TRUNK SEWER PHASE l DB 23108PG 43 560 MB LOT\ T22 PG4303 \ DB 7636 PG 613 45 / \ \ / \I MB \ �+� �^'� PLAN 1" = Know what's below. PROFILE 40' MB 22 PG 303 _ 22TPG 303 11" \ \� / \ \ Call before you dig. - 4' PLAN AND PROF/LE Ma \ \ \ \ Ver. Vert. - Ma STA A43+00 TO STA A49+00 / \ As Built Date —� M� \ A 2 16 TED FINAL DESIGN L. ASSOC JEM Sheet TED MEB 5/1/18 Off V — \ No. Date By Revision Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT W OO Q to = o 10to to UN BIW W� jI X10 OV� � Q II Q (3W) II Q _ \ i 0100 Ln \ STREAM YR HAZARD FLOODPLAIN AREA (TYP) CROSSING 6 6 EXISTING GRADE CENTERLINE (APPROX.) O AT O O - O O7 Q 0 MATTING (NP) SEE DETAIL SHE T 25 � Q O I _ - Q MIN. COVER 3.0' - -- - -- W EXISTING STEVENS CREEK BOTTOM (APPROX 6512LLJ zv _ _ -- - -- - -- -- - -- ` PVC SANITARY SEWER z -ifit W - PROP. 16 U LLJ I PVC SANITARY PROP. 16" PVC SS U Ld � (/) 16" SEWER ®0.50 0 Q PROP. -- 16" PVC SS PROP. 16" D.I.P. SANITARY SEWER ®0.50% PROP. IN = 644.20 ®0.5 0% PROP. OUT = 644.00 ®0.37 o I I I I 4 4 PROP. f IN = 641.98 __j PROP. OUT = 641.78 4.9 O+ 1+ 2+ 3+ 4+ 5+ 6+ 7+ 8 PID #19523116 WYANE LAMAR SIGMON STA. A49+60.55 & MARY K. SIGMON J DB 2042 PG 270 _J _ _ -j �� I �_��' \\`\6S\ ,/ / PROPOSED 4' / / \ --- J _ �/- --______ t \\�\\ DIA. MANHOLE MH -15 -__ _// 200' BUFF R LINE / `� - - _ - - ` ��/ - - �,Lfl STA. A53+63.26 W VENTED // -'-----_;__, ,/ �� /1 \-- -�IBH-7 / ---- >„�____ �.- _--_ FRAME & COVER %/ _ — _ / PROPOSED 4 i -_, > � _- ___ / - - // /� i ' �_ _ / _- - - - - - DIA. MANHOLE MH -16 \ e� PID #19523106 ---� MECKLENBURG COUNTY — �\ PERMANENT SEWER � EASEMENT (TYP) i/ j � j� / � ' _ _ — _ -- — ��—_ �- W/WATERTIGHT — — _� � \ � � � _ _ 4 — DB 12412 PG 394 TE — — _ \ DITCH (TYP) _--_ FRAME & COVER PID #19510136 /ML _ _ CLYDE DANIEL TURNER -� \_---- ----- � �• DB 5218 PG 004 ./ --- 100 YR FLOODPLAIN 660, HAZARD AREA (TYP)PSUE Psu� n EROSION CONTROL0 TSD PSUE TSD PSUpMATTING (TYP) J 00 N82'10'S5"W A51 +00_� rsD PSUE SEE DETgIS�/EET�2�7 402.71' A52+00 �j' TSD rs�D r 'TSD SUE ��7 A53+00E v //rco g� tTSD PROPOSED �Su16" SAN/TARY SEWER PSE � � 5� TSD � � � � � _ lel y o Sy6 561.Q �6 / _ i �% PSUE S y`/ �05�e5J� / \ \/ / Ps A54+OOp �srE► PID #19510137 Q / _ PSUE Ps ` _ / �`� �i ITSL) — / CLYDE DANIEL TURNER O PSUE A55+00 Psu % / / DB 13710 PG 684+/� 01 TCE T 20� \ + PSUE / _ / - 655_ 5 5 % — — T TC� J — + \ r � A56-i-00�J TC TICE TICE RSO ^ /�/ `p / S /•(� PERMANENT SEWER, r* EASEMENT (TYP) �� TCE — L� / i \ Ps rcE w Ljj r\ / A57+00 s0 PSUE f'ROPpsE-p 448,50• \ 7 r�n L \ �\ /;� v//=��_`--�__— 700PORARY �' — = �� - - _ —� — SAN/T�p _ -- + = ���\ — — — — // i ��/ / PsuE A Y SEWER \ \\� vl AS 8 O �n lY �11CONSTRUCTION / - _ — — — /�— — TCE — — = — — \EASEMENT (TYP} ,��� /_ \ `�I�` /�/ �\ E UE _ kTEMP. DIVERSION DITCH TYP '�� 7 ( ) TEMPORARY ROCK � -SEE DET SHEFJ 2� ✓ SEDIMENT DAM � — — — —= = = �I — ' \\\ \ \\ /� ' �— = —= — _!�_ _ _ -- —\\� / r — ` REINFORCED STABILIZA ON j TICErcE rc PSUE �� VA A �- / E rc ` OUTLET \ I (� TONE CHECK DAM (TYP)\ WEIR = 12� l \SEE DETAIL SHEET 2¢m \ TYPE B (TYP) � SILT FENCE II �\ \ _ SEE DETAIL 25 r SEE DETAIL SHEET 23 \ rcE \\\\\\ \ / _ � /—�\ — \ ` _STEVE S CREEK —� J X — �� _ _ —_— _= + _ , R POP SE6 STEVENS /' —\\ \3 _\ ✓ — zz 7- CREEK TOB (BY OTHERS) \ /I \ X X GHD Consulting Services Inc. _ ✓ / / �./ / / �66� \ \ _ — _ , _ 50' BUFFER LINE \ / / ETEVE , Know what's below. 222 South Church Street, Suite 400 PID #19517146 .--� MARGARET RHYNE BIGHAM '` / — xI \ �' — S GREE / PID #19516201 PID #19516202 / PID #19516203 \ x PID #19516204 _ \ — 0' BUFFER LINE r MICHAEL P GOLIK / LUANN M JENKINS I WILLIAM E GENET JR — / MICHELLE MARIE MCFALL �X ,/ — N_�� y PID #19516205 PID #19516206 Call before you dig. Charlotte NC 28202 USA �, T1 704 302 4910 Wwww.ghd.com & LYNDA BIGHAM EVANS / DB 27507 PG 32 LOT 46 / DB 18649 PG 969 / DB 5849 PG 531 I DB 10576 PG 26 X I DB 23235 PG 890 i r \ AARON K FORSYTH 660- — - STEVEN M ADAMS & LOT 27 / LOT 28 LOT 29 LOT 30 & ASHLEY E FORSYTH - �_ _ / JOSEPHINE ALBERICO ' MB 21 PG 957 MB 21 PG 957 \ MB 21 PG 957 MB 21 PG 957 _ I 1 / DB 29839 PG 660 — DB 19279 PG 690 ' MB 22 PG 303 x LOT 31 LOT 32 MB 21 PG 957 _ MB 21 PG 57 CHARLOTTE CHARLOTTE W6TER WATER CHARLOTTE NORTH CAROLINA 7030700b No. File Job No. File No. STEVENS CREEK Scales PLAN 1" = 40' TRUNK SEWER PHASE I PROFILE Hor. 1" = 40' ," = 4' PLAN AND PROFILE Vert. STA A49+00 TO STA A58+00 As Built Date A 2/16 TED FINAL DESIGNSheet L. ASSOC JEM TED MEB 5/1/18 1 � Of 26 No. Date By Revision Surveyed By Designed By Drown By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT 0 0C 0 �Z CIC WM + I� V c0 Ntp co oZLAJ + hW I� v to W to 41 ~ Q (z)101) _j Q 43 Q) II N O W ^ J Q4 N ( Q_ Qp, O o +ip to W tj 1 (370 I N p ~ to _ O °o W W� Q p^ Z i; Q C V_ I I Q 4 I y p Q STREAM CROSSING #5 THOMPSON RD. T O `� 1 100 HAZARD YR FLOODPLAIN AREA (TYP) Q O Q z EXISTING AT CENTERLINE GRADE (AP,,ROX.) ROSION CONTROL I UTA s" GAS (/') W W W = MATTING SEDTIALLS)EET25 I III III I I 6 6 z_ C/)- 16" D.I.P. WTR _ _ -- r = W U (n XIS NGS CREEK BOTTOM VEN APPROX. _ -- - -- -- _ // - -- -- / - _- - I I �yA `_ �- -- _ -- -- /� i MIN. COVER 3.0' 18" MIN. SEPARATIO I 16" I CAP OR' PLUG PROP. IN = 648.93 5 PROP. 16" PVC SANITARY SEWER 5 PROP. 16" PVC SANITARY SEWER I PROP. OUT = 648.73 — 00.20 Yo STA A65+40 ®0.20^' INv = s4s.3s PROP IN 646.64 — PROP. IN — 647.72 STA A64+71 INV = 648.,00 PROPOSED LF PROP. OUT = 646.44 IN OF 30 CASING PIPE 1:1 THEORETICAL P. OUT = 647.52 PROP. IN = 648.31 EMBANKMENT PROP. 16" PVC PROP. 16" D.I.P. SANITARY SEWER PROP. OUT = 648.14 00.20% SANITARY SEWER 00.50% 8 9+ O+ 1+ 2+ 3+ 4+ 5+ 6 200' BUFFER LINE S TEMPORARY CON�TRR CTION 665 \\ ► I \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ EASEMENT (TYP) ' STA. A62+54.79 V \ I I 100 YR FLOODPLAIN ' TEMPORARY CONSTRUCTION I _PROPOSED 4 / ENTRANCE \ \ I I I 25' \ \ II (I I \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ 7 \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \ \\ \ \ \ - HAZARD AREA (TYP) � - DIA. MANHOLE MH- 18 1✓ \ \ I I� I ` \ \ I �� � PARCEL #19506127 i C /6\ w/w,a rERricHr PROPOSED STREAM I I RESTORATION STAGING \ \ �I I 1 / p RONALD COX 14709 THOMPSON RD, \ \ PID #19510137 � I `� CLYDE DANIEL TURNER PID #19510101 FRAME & COVER MEETA J TURNER AREA �►I \ I / I \ Z \ /� �^ - DB 13710 PG 684 STA. A58+11.76 DB 10105 PG 273 - � l V) ~ _ ' PROPOSED 4 / - SILT FENCE (TYP) \ - - - I I I TCE _ - \ O= TEMPO ARY STREAM — — D/A. MANHOLE MH -17 _ _ 660- — ' SEE DETAIL SHEET 23 _ _ _ _ \ _ _ Ir- n- - -CROSSING (TYP) SEE DETAIL SHEET 23 -- W/VENTED PERMANENT SEWER �< % EASEMENT (TYP) cE GE cE Q �" I \ 15'x4o' FRAME & COVER G cE I I I II LAUNCHING PIT — s�o�� STA. A64+63.77 \� p62+oo PROPOSED 5, °0 \ \ DIA. MANHOLE MH -19 / A61 +p0 ps�E \ / 3 \ I W/VENTED ' +oo , 4,3 "W PSUE A60 N61 443.04 SEWER ?SUE 15� SANITARY °� o 'I'?s;��, ps F TCE rcF s� sF� , ?p8 �.9 d� I I I sas98• I ` � II I IyI' FRA ME & COVER / cd < – A59+p0 -TCE 16" PROPOSED psuE T TCE rcF '4'QY /III \ I 1 g64V60, II 15'x20' - 15' PSUE TCE ICE ` rc SF* OF 1 1� \ ICE � � � s�F �— \ 41 ; �_ RECEVING PIT TEMPORARY CONSTRUCTION ENTRANCE pSUE TCE TCE � W"7 r ` �?�j � s E � -�� PsoE / TCE TCE \ � W _ - -. ■��! ` F \ I �� I A65+00 PROPOSED FUTURE A65+48 SS EXTENSION TCE / 000 A� RS / 0 \ woo_ — _ 660 x / l X-' REINFORCED STABILIZATION \- I I = _ STA. A65+48 � PROPOSED 5' - = -_ - = - - -� - - L �=�� -- — — —— �� OUTLET TYP - � = - / � - (TYP) / / SEE DETAIL SHEET 25 / ERRIANENT SEWERS l - --_` _ 1_ \ \ �ii �� /i �— DIA. MANHOLE MH -20 - ,_— / � �% _= _ _ � /� - _� � - �� �_ - _-EASEMENT �� \ _ ^�� - \\ 1 _ _= J/� __ TYP - - -�___ - - _ - - - _ _ R 10 CONTROL J- - ay TTI NG \ - - - I � j 1 ��%� W/VENTEDA \\L� -�7 'EXISTING / 50 BUFFER LINE \ TEMPORARY --s E DET IALTMSHEF.J�5 - = _ �� - _ CONSTRUCTION +- _� _ FRAME & COVER - Q �� STEVENS CREEK \'I I 1 1 \ _ EASEMENT (TYP) x �— x — ~ x \ - - _ �- \ r ' \ \ \ - - / 30' BUFFER LIN Ii\ I - �_ ` ^ EXISTING \ \ x fi F // PROPOSED 68 L /� - / - \ \ ✓ cp PROPOSED % k STREAM TOB J I I • \ I� -�\ ` STEVENS CR EK J / -__� .�. I OF 30" CASING PIPE , / _ - - / �llj �� �_" 0 40' 80' �I -----_ ,-_ N56°0323"W O _�/ / I I-II'I I \ /�_ —_— __ --- -- — - --y►�x 100 YR FLOODPLAIN �� hI \ ,I y ` I 84.23' PROPOSED 16 / / / _ ` // /// ///'- ----- GHD Consulting Services Inc. \�' PID 19516207 # I \ / HAZARD AREA (TYP) \ \ \ — \ \ _ ANITARY.-SErWER % / // / / / / / / / / / / / / — — — 222 South Church Street, Suite 400 CAROLS A BRENNAN DB 7266 PG 977 (� I 665' / / \ '`'I� / + \ / / I I � / � � \ / �� X \ \\ \ \ I / \ I � \ � / / / � _ _ .66`'// j / / / Charlotte NC 28202 USA \ T 1 704 302 4910 W www.ghd.com LOT / III - - ( x �� ' I / \ 3' / / MB 21 PG 957 G PID 19516208 I PID 19516225 - / # I II � # / TARRA G DEAN I I DEBORAH S WILLIAMS \ PID #19516226 PID #19516227 NC RE INVESTMENTS LLC MARK S PERRY & JASON C DEAN \N� DB 7525 PG 775 \ \ DB 12272 PG 728 > ) LOT 51 / LOT 34 ` MB 21 PG 363 MB 21 PG 957 I DB 30048 PG 917 / & SUSAN M PERRY LOT 52 / DB 17371 PG 335 MB 21 PG 363 LOT 53 I B 21 PG 363 \+ M11 CHARLOTTE CHARLOTTE WATER / I l - / W6T E R CHARLOTTE, NORTH CAROLINA \ I J / 7030700047-17-503 STEVENS CREEK Job No. File No. NOTE: / / �' / / — \ \ \\ 11 I / / _ — _ Scales 1" - PLAN 40' TRUNK SEWER PHASE I / \ �\ \` I x _ _ J/ — — — Know what's below. PROFILE EXCAVATIONS SHALL NOT ENCROACH UPON THE DESIGNATED 1:1 , THEORETICAL EMBANKMENT LINE. SHORING AS REQUIRED SHALL BE PROVIDED I x— _ _ �� _ \ Hor. Call before you dig. Vert. 11 - 4o PLAN AND PROF/LE BY THE CONTRACTOR. SHOULD MODIFICATIONS TO THE LIMITS OF THE BORE I I �I 11 I I PIT BE NEEDED APPLICATION AND MODIFICATION OF THE NCDOT CROSSING I -� � I I STA A58+00 TO STA A66+00 PERMIT SHALL BE COMPLETED AT THE EXPENSE OF THE CONTRACTOR. / \ i /I/ / I I As Built Date / v I / I A I , I 2 16 TED FINAL DESIGN L. ASSOC JEM Sheet TED MEB 5/1/18 1 1 Of 26 / /I No. Dote By Revision Surveyed By Designed By Drown By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT W J O LU Q j QO 65 �Iz � + � 6-4 1 1 1 650 O O NQ Q 0 N O J W = J �OIOSA! -I.O Z UWP QQ CIO i41 II t j �p pl VOj p ti =�2 + W �O m �II NJO O l to � h I to Q; _ 4,�3Q; O O 00 YR FLOODPLAIN HAZARD AREA (TYP) z II a,�3Qo; Q Cn W Qz (%) XIS AT CENTERLINE NG GRA E (APPROX.) 6 4 LJJ w 6,10 LLJ = LLJ LJ z U)MIN. __J LTJ COVER 3.0' EXISTING STEVENS C TRIBUTARY BOTTOM EEK APPROX. -- - -- - z (/') Cn ` ANTI -SEEP SEE DETAIL COLLAR SHEET 21 PVC SS PROP• 12 PROP. 12" PVC SS � -SEEP DETAIL COLLAR SHEET 21 ANTI SEE -SEEP DETAIL COLLAR SHEET 21 ®0.60/ o 17 PROP. IN ®�•60 = ° 630.75 63 ANTI SEE 6,30 7 7 ANTI -SEEP COLLAR PROP. OUT = 630.55 SEE DETAIL SHEET 21 PROP. IN = 628.29 PROP. 12" PVC SANITARY S WER PROP.l OUT = 628.09 ®0.60% — PROP. E IN — 626.55 PROP. /N = 626.80 PROP. 12" PVC SANITARY SEWER ®0.60% PROP. 12" ®0.60% D.I.P. SANITARY S WER _ PROP. OUT = 625.80 PROP. 24 " D. 1. P. SS ®0.50% PROP. 12" ®0.60% D.I.P. SA Nl TA R Y SEWER tt BO 1 2 3 4 5 6 7 +_+11 --, 77 000 01 ��//� .Z� REINFORCED STABILIZATION i PROPOSED STREAM \ \ \ � NOTES: — i I OUTLET (TYP) �� \ � FENCE EPLA�GEM � � ���5 E DETAIL SHEET 5 ` /// ��� RESTORATION STAGING AREA \ \ \ \ \ \ ' \ CITY OF 1CHARLOTTE \ \ . 1. CONTRACTOR SHALL PROVIDE AND //// �!• ` o / \� LOCATION x� ` I COITTRACTOR SHALL REMOVE AND REPLACE 3 STRAND ELECTRIC WIRE EXISTING STEVENS \ — _ DB 30613 PG 431 \ \\ PLANT 9 GALLON SIZED EVERGREEN TREES THREE (3) PER LOCATION + G\� j j CREEK TRIBUTARY \ \ ` \\` FE IDE LIMITS50' WETLAND BUFFER ALONG PERMANENT EASEMENT LINE N, J a � / E W x TEMPORARY NT \ TcFx\� �t� �- s C ® �� \ _(SEE DETAIL SHEET 26 FOR FENCE REPLACEMENT) Y \ \� \ AT MANHOLE #7 8 AND 21. i POA ORD CROSSING \ — x x -- _ 41 ` k��•�� STREAM BANK \ STABILIZATION (TYP)���� SEE DETAIL SHEET 23'\ QS, � � - / \ k \ \` ice / / TEMPORARY \ CONSTRUCTION EASEMENT (TYP) \ "W x \ J ARM GATE 00 N 2?,� SpN�1 PERMANENT SEWER EASEMENT lYP 10 (TYP) / (FOR DETAIL / X SEE SHEET 26) g1'� 12 SEE NOTE 1 �Io y _ S REDUCE CLEARING TO 40' x �/ ° pSU Q R Q x� + _ \ — l OF / �/ �� ✓ \\ �o STA 63+70 TO STA 65+00 _bPOSED \ A25+00 �� �� PR STE N CREEK TOB (BY OTHERS) STA. B2+ 14.46 B2+14.46 + /SILT / / F P SEE DEN IL (TYP) H ET 23 64x00 T �\ 1 PROPOSED 4' ! �; �\_� \ O ��E / p x ��_` — O \ v / •30 BO+00 ANTI -SEEP COLLAR DIA. MANHOLE MH -21 x r� , W/WA TER TIGHT 7 �pOS N��S pS - \ ANTI -SEEP COLLAR ` 1a g ,, SS / b• Z / / �� SEE DETAIL SHEET 21 SE NOTE 1s . • . . F Fp 8' �\ F FRAME &COVER • .? S� DETAIL SHEET 2\ \ �/ e SEp _ � � 'STA. A24+83.26PERMANENT S SF�F � _ Q- O /� / STA BO+OO _ — — PROPOSED 5 EASEMENT (TYPWER FENCE GATE FOR psUB5+00 DETAIL SEE SHEET 26 \ ANTI -SEEP COLLAR SEE DETAIL SHEET 21 D/A. MANHOLE MH -08 _ — — _ ~ ANTI -SEEP COLLAR . OF rcF / �/ C SEE DETAIL SHEET 21 ` \ 4 �/ W/WATER TIGHT '� _ H-10 � � � � _ 1 / pSUF rc� \ -� —� FRAME & COVER r — - \ v � 100 YR FLOODPLAIN ` \ J _ + HAZARD AREA (TYP) � _. STA. B5 91.49 / 50' WETLAND BUFFER i 1 \ PROPOSED 4 1 D/A. MANHOLE MH -22 ! _ _ — — / $ r PID #19517155 I W/WA TER TIGHT - — JAMES R WIGGINS JR FRAME & COVER & MITZI C WIGGINS - % \ DB 8064 PG 520 / _ "W MB 26 PG 598 N29'2448 --- ___--- / —' 392.71' / BUFFER LINE PROPOSED 12" SANITARY SEWER GHD Consulting Services Inc. _20_0' 0 40' 80' 222 South Church Street, Suite 400 , Charlotte NC 28202 USA // ------_ T 1 704 302 4910 W www.ghd.com -- �� PID #19517150 ROBERT A WINFREY - // DB 2996 PG 144 CHARLOTTE CHARLOTTE WATER W6TER CHARLOTTE, NORTH CAROLINA • / / — — — — — — — ® 7030700047-17-503 Job No. File No. STEVENS CREEK Scales PLAN 1" = 40' TRUNK SEWER PHASE I Know what's below. PROFILE 11 Call before you dig. PLAN AND PROF/LE Ver. Vert. - 4o - STA BO+00 TO STA B7+00 As Built Date A 2/16 TED FINAL DESIGNSheet Of L. ASSOC JEM TED MEB 5/1/18 � 2 26 No. Date By Revision Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT W i� A m Q p ` 41 Ftp O1* 2 II ONS THOMPSON RD. 74t C- 2 C9 + W�tVp m p�� II = N p h yl�� tQ p + O W p co m OtoJ :r: tV II v1 os-I� 00 II � Q. A 3 QC I W v = W 00 W 4pit�p � CIO tn tV W II ~ � _\� 5 - 5 ti�a�3o; ur 100 HAZARD FLOODPLAIN AREA (TYP) UT(2) 6" GAS Q E ISTING RADE O Q AT CENTERLINE (APPROX. 3 O N EXISTING TRIBUTARY S VENS BOTTOM C EE (APPROX.) I 0 �� - O z I 16 D.I.P. WTR - - Q z MIN. COVER 3.0' (% V 4 W - -- . -- -- -� SEPARATION I PROP. 12" D.I.P. SS W W 4 W z= �, ,.------- ------------------ A _ __ _- PROP. 12 PVC SANITARY SEWER ®0.50 0 W = z - (� = PROP 12" PVC SANITARY SEWER J W -I I®0.5090 PROP. IN = 638.17 = W C) Q PROP. 12 PVC SANITARY SEWER ®0.5090 PROP. 12 D.I.P. SANITARY SEWER ®0.5090 PROP. OUT = 637.97 Q SANITARY ®0.60 YO SEWER PROP. 12 "PVC 00.50% STA 811+88 INV = 634.02 - PROP. 1 IN - 636.81 STA B12+55 INV = 634.42 PROP. OUT = 636.61 PROP. `` IN = 6. 'L .47 1:1 B NK ENT LIN PROP. PROP. IN = 633.30 I I r OUT = 633.10 3 PROP. PROP. OUT = 634.27 PROPOSE 7 F 24" CASING LF PROP. 1 PROP. IN = 635.14VER PIPE 00.50% PROP. OUT = 634.94 3 10 11 12 13 14 15 16 17 18 19 - \ / 'y \ / - - - _ - _ / i�� - / ✓� -7 T��� / / - �� / // /� " -^i '- - MICHAEL R & - i� JOHN ANTHONY GRUE - - �- BECKY BOBZIEN-SIMMS ANGELA B KROLL �� PID# 19508159 i� & T NEY SIMMSI �\ \ I \ MORITTZDPROPERTIES50816LLC //- \ \ \ / / I _ /o \ \ \ l l I I \ \ \ 0 `�/ __ \ \ ii \ \ �_--� \\� - _ _ \ / /��% - - �� i�i� _ - _---_ -= io �� / -_' --�� I I I I I \ \\ ss #COS _-//,/� ��� - _ i �� PID 19508161 �y� LOT 22 / / PID 19508158\\ =-���� DB 29543 PG 406 J/ / LOT 218\\\ ��� LOT 215 PG 488, 49 \ - DB 26978 PG 870 // J V _� ��DB 30678 \ B 56 PG / DB 30627 PG 990 \ - - MB 56 PG 49ld \ - -650= �- \--ce//- ''� PID #19517148 \ �J III MECKLENBURG COUNTY7.4�DB 24891 PG 862 MB 56 PG 49 iiiii s�; \ �� _ _ /��i/// "'TEMPORARY ���' -J / ` ' �' \ \\ \\ '_ �\ PROPOSED STEVENS CREEK 1 I \ ROCK 0 OSED STREAK SEDIMENT DAM �_��� //� i ESTORATION STAGING AREA INSTALL FIBERGLA � 10 � / \ - MARKER, SEE �� I x ��\� \ _ TRIBUTARY TOB (BY OTHERS) j \ / - r -1 I \ _ �� ,WEIR = = „ / / / 'SS _ / - - DETAIL SHEET 17 =TYPE B (TYP) - //� / STREAM -� / / MPORARY TEMPORARY / CONSTRUCTION ` I 3 c �,.-. N ,�: /% /// EST ATION EASMENT / CONSTRUCTION X \ f EASEMENT (TYP) - i \ EASEMENT (TYP) _ I !` J �� / a� EXISTING STEVENS / 30 %� 6 / /// STALL FIBERGLASS �// / / x i // / � SS MARKER SEE // ( / `� / �/� CONTRACTOR SHALL REMOVE ' AND REPLACE IN-KIND �� ONTRACTOR SHALL � �� \ EXISTING 4 -RAIL VINYL \ REMOVE AND REPLACE CREEK TRIBUTARY _ \ - - - r DETAIL X \ PERMANENT SEWER /� �-- / IN-KIND EXISTING. \ EASEMENT (TYP) / /,% x �� I _ _ / I x + REI FN ORCED STABILIZATION 4 -RAIL VINYL�NC� '\\ / OUTLET (TYP) ` S SEE DETAIL SHEET 25 TA. B 17+97.41 '+ PROPOSED 5 � T $ TCE E D/A. MANHOLE MH -27 T / l/ / cE T� W/WA TER TIGHT ) �e�s+ 30 I E g15+oo: 10 x Oo PSUE TCE rc FRAME & COVER , TEMP. DIVERSION DITCH (TYP), EE DETAIL SHEET 25 ' l l lI I p \ - E -TEMPORARY ROCK SEDIMENT DAM ` ' T III / / I g14 30 53 .1x00- N3TE �w / 57 % 2g3SANITARY SEWER s E 10 8�7+ DO Tc `� \\ O suE e / x P • . \ wooTYPE WEIR = 12' (TYP) B TYP �c / Tc D / I ( / I I / E ROPOSED,yt 2 / 1 P PsuE N16.4¢b p Q ' TCE Tc �� / / ,� g13+OD / 10 cwopPosEp 124 W (� 2 SAN/ B18+00. •• -I- / _ / 1 - CE TCE D ,� �� N TC TC TC TCE �� Tc g12+0 o / TEMPORARY I PSUE CONSTRUCTION 1% t Y SEjy + r, qR - \41 STA. B 15+64.77 I / N1 ` TCE ICE TC TC TC �� D P�E� r / I EASEMENT (TYP) SILT FENCE (TYP) l / \ SEE DETAIL SHEET 2 PROPOSED 4 _ - 65° '°RO�o- - X k Ep iY m O 30' // pStB11 1.00 PSUE �/ / " TREE PROTECTION PERMANENT SEWER AROUND 3 PINE TREES EASEMENT (TYP) D/A. MANHOLE MH -26 t?SS �, e19 Y I W/WATERTIGHT FENCE kAN�r �� , , Q z PsuE X69+00 PSUE BB+oo _ N36.32'18"W 192SANITARY SEWER PSUE g10+p0 ' 12 r,�t ��E /� 1 / / / / I I / 11 T E ICE STA. B 12+71.21 E _ REPLACEMENT - / , , 0 ( FRAME &COVER �• WETLAND BUFFER LOCATION x x V I 40 80 00 0' N2924'48'*W' --. PROPOSED pgUE / / l/ I / I 15'x40' PROPOSED 5' II BH W '_ 6r --:-=o TstPROPOSEDr�129 SANITARY SEWER;o P E TSD TSD PSUET i �' -"� �� C , / / / / / /I /� // -12 LAUNCHING PIT D/A. MANHOLE MH -25 100 YR FLOODPLAIN TEMPORARY W/WATERT/GHT HAZARD AREA (TYP) EXISTING 4 -RAIL .� x \ ' �"' /� VINYL FENCE TO BE RELOCATED. W W ' / _ - " / / = //�/ I J CONSTRUCTION ENTRANCE FRAME & COVER � / / \ x \ SEE NOTE 1 , z = - J PERMANENT SEWER TEMPORARY SILT CHECK TYPE B EASEMENT (TYP) W/ SILT BASIN TYPE B SEE DETAIL SHEET 25 //0 j i I , // O I I i / Q I -- _ �� ^ = - PROPOSED 12 I x - \_x - - - - - _ _ _ - _ - • T O l o - = = SANITARY SEWER RPIR1A�11FR Y OBE WN E \TCE\TCE / _ - �� / Z f - 'N3T30'S3"W ' �� �� ,---' x�------- _ ` x (� Q / - _ DB 2996 PG 144 TCE TCE R_ 4 frj ' Q 94.12 - - PID #19508105 _ _ I x Know -I _- 11----x--_- - - _ _ CHEVAL ASSOCIATES LLC ` x \ what's below. Call before you dig. TCE � CLAY A. LITTLEFIELD & � - - - PID# 19508131 x _ STA. B9+84.20 / � 15'x20' - - - STA. B 1 1 +77.09 RECEVING PIT r = , � JENNIFER LITTLEFIELD � � � i DB 30900 PG 385 I � - DB 19418 PG 1 - - - MB 44 PG 425 _ _ , _ PROPOSED 4' PROPOSED 5' 200' BUFFER UNE D/A. MANHOLE MH -23 TEMPORARY D/A. MANHOLE MH -24 CONSTRUCTION - - / / 2 - - PROPOSED 77 LF / / '6�5� OF 24" CASING PIPE / / / CONTRACTOR SHALL SECURE GHD Consulting Services Inc. SITE WITH FENCE TO PREVENT 222 South Church Street, Suite 400 EQUESTRIAN ENTRY DURING ALL / I VENTED ENTRANCE W WATERT/GHT FRAME & COVER `FRAME & COVER � / � � � � � PHASES OF CONSTRUCTION Charlotte T 1 NC 28202 USA 704 302 4910 W www.ghd.com � - /� I650- 3 ' ' ' CHARLOTTE CHARLOTTE WATER W�T E R CHARLOTTE, NORTH CAROLINA z// ,�� NOTES: ' 1. PRIOR TO SEWER CONSTRUCTION CONTRACTOR 7030700047-17-503 STEVENS CREEK SHALL REPLACE FENCE BETWEEN STATION Job No. File No. 18+00 TO 30+80 AS SHOWN ALONG Scores 1" = 40' TRUNK SEWER PHASE l PERMANENT SEWER EASEMENT WITH IN-KIND PLANEXISTING 4 -RAIL ACCORDANCE WITH VINYL CONTRACT DOCUMENTS. PROFILEHor. 1" = 40' vert. 1" = 4' PLAN AND PROFILE STA B7+00 TO STA B19+00 As Built Date A 2/16 TED FINAL DESIGN L. ASSOC JEM TED MEB Sheet Of 5 1 18 13 26 No. Date By Revision Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT W J 'IQ" aq 05 LQ o W W� 0 2 II M `O'Q +I� +C v��o C. � I �00� 660CNI6130 O m p coo I I ANO h I� 3 Q QC 100 HAZARD YR FLOODPLAIN AREA (TYP) it EXISTING GRAD AT CENTERLINE (APPROX.�- m 0 Qz - G O U) LL] W LLJ EX TRIBUTARY SUNG S VES BOTTOM REE (APPROX.) �- 1� i� - 1 MIN. COVER 3.0' ` _ Lij Lij (n 1 -- -- - -, PROP. 12" PVC SANITARY SEWER Q V/ 12" PVC SANITARY SEWER ®0.50 o PROP. IN = 645.19 PROP. OUT = 644.99 PROP. PROP. 12" PVC SS ®0.50�G PROP. f IN = 642.91 6 0 PROP. OUT = 642.71 6#0 ®0Z oz.509' PROP. FL /N = 640.13 PROP. FL OUT = 639.93 PROP. 12" D.I.P. SANITARY SEWER 00.50x 1 9 20 21 22 23 24 25 26 27 28 29 E330 00 31 \ \ JASON C & — MORITZ PROPERTIES LLC i \ _ / �` MORITZ PROPERTIES LLC — ' MORITZ PROPERTIES LLC • • ift • MORITZ PROPERTIES • Y — _ ANDREA E KNOTTS PID# 19508156 / � \ — \ � PID# 19508155 — — PID# 19508154 / LLC PID 19508157 — — — LOT 220 / LOT 221 LOT 222 PID 19508153 1., LOT 219 DB 26978 PG 870 ,�' / � , � / � = DB 26978 PG 870 —14 -, DB 26978 PG 870 / � + COMMUNITY WELL LOT I # — — — — \ / — # — — — DB 29473 PG 495 MB 56 PG 49 \ MB 56 PG 49 MB 56 PG 49 / DB 26978 PG 870 �— ��\ • • • • • • PROPOSED STREAM RESTORATION STAGING AREA / '�\ � � + \ MORITZ PROPERTIES LLC 1 \ \ 100 YR FLOODPLAIN � \' PID# 19508152 — 1� — — — \ LOT 223 HAZARD AREA (TYP) \ \ _ , \ � DB 26978 PG 870 \ MB�56PG 49 1 MB 56 PG 49 -- ----- ell + STABILIZATIONPERMANEN� SEWER_ \ — �, \\+ // + ' MB 56 P. G 49 — PROPOSED STEVENS CREEK— \ + \ \ \ \ \ \ 77RY TOB (BY OTHERS)REINFORCED - OUTLET (TYP) - - SEE DETA L S EET 25 _ _� EXISTING STEVENS i + EASEMENT (TYP) I TEMPORARY III \I� % �� / =� _-J%' / \\ /i \ \ J : / /i _ __ _ FENCE (A;; \ \ / + CREEK TRIBUTA__ / �- -� - - _ _ _SILT ONSTRUCTION/ / \� \ \__� - -; ±_ _ ���� _ _ ��___1__ _ - - / \ -SEE DETAIL SH ET 2*3 -- //I/ r J�� ��-� EASEMENT (TYP) - f --ft mmj memo �' �\� TCE k �- T TCE —� — \�� ��/�� \ / Now� / -_//% - - ii / III I ✓ `\TCE TCE SCE TCE� TCE / \ w CE C� \\\\� + T + o \\✓ 0 TeE- TCE TCE r v\\\ O /+ iCE TCE TCE �..�'�-U'� \ TCE TCE TCE TCF \ + TCE TCE TCE _� TCE TCE — _ _ _ _ \ — E� E TCE / /� T J \ \ T ` �' \ \ / T — T / — r — — — — V - SU r- 30' \ \ // \ — �.� -- PSB26+00 / -... �- - PSUE PSUE B25+00 824+00 B27+00' PSUE — - - - \ T R6D \TCE / / \ PSUE 1928+00 + S E \ r- 00"x- PSUL J + PSUE X U 2B 3 0000 x x x x x x —� 52 W _ _ _ _ — NOT3358"W 1929+00 ' m ' 0 - B20+00 - N10'49'17"W 10' 821+00 r N161 X P r suE B22+0� 515.30' E / X " SANITARY SEWER x / - — — — — ---. � �.. 0. 415 4 B30+79, � ROPOSED 12" / SAN/TgRy B30+00 PsuE / z x Q 351.20' PROPOSED 12" SAN/TARY SEWER x x _ - P E" _ x x x T I'� / / / / �� EX. 15" FES, .Owl 1x ,EWER - - ' � �\\ — — — / / ~ PsuE x x x Ps BH -13 x x x REPLACE_ / / RIP—RAP APRON ��"- f J / / �� / x / / / \\ — _ _ " / X I � EX. 12 FES, � _ / / REPLACE / j l A. (/) -� LLJ W W .� EXISTING 4 -RAIL VINYL FENCE TO BE RELOCATED. SEE NOTE 1 r / / �� ' FENCE REPLACEMENT / / - / LOCATION / / I� -'� - / , / - - -.► _ - / / \k, _ APRON _ - _ F=q / / / \\\ = RIP -RAP / " - - - - / / \ EX. 30" FES, _ __ _CON Ih'ECT T6 _ - EXI TING FENCE / \\ EX. 12 RCP_ - REPLACE / O 40 80 / \ - _-- = z x / - " EX. 15 RCP --- _ _ _ - - / _ _ _ - - , / _ - _ / / / / _ / / \ RIP -RAP APRON �_ \ ------ --' / �\ / \ \_ /� �� //--}� __ �/ `... 'PERMANENT SEWER / / - - - EASEMENT (TYP) _ I STA. B26+63.92 / // ///- _ ---- - EX. 30" RCP / / / - x - FENCE REPLACEMENT � ' / / / X - \ - ~• ✓ -•� 'Lij / PROPOSED - - _ 4 - _ - - / - - - / / �` Q //� - --_ / _ _ _ __ /- - _ - _ //�/ �/� - D/A. MANHOLE MH -29 '` // - - x , x x — --x x ix x x x / W/WATER TIGHT __ , , // -- I,_ __ STA. B30+79.35�-• - _ PROPOSED 4 / STA. B21+48.61 _ - X -__x x /� x �' D/A. MANHOLE MH -30 -__ - X x x / x x x PROPOSED 4' _ - -655- - - - / / - / / FRAME &COVER D/A. MANHOLE MH -28_ _ ` — — _ \ — — — _ _ CHEVAL ASSOCIATES LLC / / / / / / -x \ — —' — --__-_-_ _665 - ' W/VENTED _ CHEVAL ASSOCIATES LLC — — — - FRAME & COVER CONTRACTOR SHALL SECURE W/WATERT/GHT SITE WITH FENCE TO PREVENT EQUESTRIAN ENTRY DURING ALL FRAME & COVER — \ \ �\ �� - - , _ -- 660, �� \ \ _ i PID# 19508131 / / — \ DB 19418 PG 1 / / —�, — — — — — — — — / / / — — MB 44 PG 425 / /�� �� —� '��` _ — — J i _ i ' — — -- �_— _----- _ — — — �� — —� — ' — — — — — — PID# 19508131 — — , — __— k _ — _ — MB 44 PG 425 x x x =— / / PARIS FAMILY LLC Know what's below. --- PID 19507103 Call before you dig. PHASES OF CONSTRUCTION - — \ / �� �� — — \ / / / �r _-- _� � __ ' _ — — -- x1000e DB 25497 PG 724 — ' ' x _ kAo A7 or, ��z \� � WARM,Jim_ — /' / //' /' � \ y / �- X. x x - GHD Consulting Services Inc. /' ss� X�/ �\ —� t X — _ \ / y- — —� \ — — — — / ,66 / \ _ \ \ / / / / / / / �'' ' /' ' x ` /' / / / f ' / \ /' iX X — �/ I \ ' / X / 222 South Church Street, Suite 400 , — 200' BUFFER LINE / � x x x / ' ' / ' ' ' x x x x x X' / Tharlotte NC 28202 USA I x // 6 / I /� \�' 1 704 302 49 0 W www.ghd.com g x �'/�/ /' '' x x' I / / —' x x_ ����/ /� X / jf/ , , , __ ► \\ , CHARLOTTE CHARLOTTE WATER W TER / CHARLOTTE NORTH CAROLINA NOTES: 7030700047-17-503 STEVENS CREEK 1. PRIOR TO SEWER CONSTRUCTION CONTRACTOR Job No. File No, SHALL REPLACE FENCE BETWEEN STATION Scales 1" 40' TRUNK SEWER PHASE l 18+00 TO 30+80 AS SHOWN ALONG PLAN = PERMANENT SEWER EASEMENT WITH IN—KIND PROFILE EXISTING 4—RAIL VINYL FENCE IN Hor. 1" = 40' PLAN AND PROFILE ACCORDANCE WITH CONTRACT DOCUMENTS. Vert. 1" = 4' STA B19+00 TO STA B31+00 As Built Date A 2/16 TED FINAL DESIGNSheet Of L. ASSOC JEM TED MEB 5/1/18 14 26 No. Date By Revision Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT `\ \ ► \ FOR CONTINUATION SEE SHEET N o. $4Q°36i'36 "W - 7 x REINFORCED I I I I 22.18'I / STABILIZATION OUTLET (TYP)" \\\� EIS NGPROPbS D 16 ` \ / ) SEE DETAIL I I SHEET 2 ` \ \ ` S7VE�� C � EK I SANITAkY I SEIWE% ` \\ \\ \ \PROPOSD \ I I \ I I \ \ \ S EA TOB TEM OR RY R I \ \ \ \ SILT FENCE (TYP) / / \ \ 0 l � SEE DIT AIL HEET 23 \1�� /CROSSING (TYP) / PLUG AND RE—BEN H / I \ \ + \ ` I \\� ISEE DFS I SHE T 23 PID #19517148 / / MANHOLE AFTER cC4 \ I N61 a 10'50 "W \ ` I \\ \\ \ MECKLENBURG COUNTY TRANSFER TRHAVE ANSFERRED \ DB 24891 PG 862 / / 229.93' I 1 -SA\YR rLUUUt-LAIN PROPOSED Z CREEK TRUNK EWER PROPOSED 12"1zN/TARY SEWER _ nD AREA (TYP) 301 m —\ \ C7 00 UE ansd' C1+00\ wCO 0 SU i TCE J / / / 0 / SCE rcE x TCF PID #19517147 00 STA. A28+10.33 — — a i / / N TCE TC i /STREAM ANK CITY OF CHARLOTTE = Q DB 30613 PG 431 STA. C0+00 00 Tei / / �� STABILIZATION (TYP) PROPOSED 5' — �` l I r' SEE DETAIL T 23 STA. C2f56.22 / O PERMANENT StWER / I PROPOSED 4' D/A. MANHOLE MH -09 7' N EASEMENT (TYP) / STA. C2+29.93 W/WATERTIGHT / PROPOSED 5' D/A. MANHOLE MH -32 w� x TEMPORARY W WA TER FRAME & COVER D/A. MANHOLE MH -31, / . / h EASEMENT (TYP) _ _W WATERTIGHT FRAME & COVER 30' BUFFER LINE \�� k �N�� G \� FRAME &COVER _ � _ � o ws 50' BUFFER LINE ` — - — \��\ \ EXI'9fNG WWTP N31 *2256" W v / PERMANENT SEWER M M _ x TEb(PORARYU STATION MH 26.29' \ / — / C EASEMENT (TYP) h O CONSTRUCTION -1 o � i / � �I� � � � PROPOSED 8" ASEMENT (TYP) II ` SA + � / � EXISIIN� FENCE T 'BE REMOVED N/TARY SEWER---_ / a /ERMANENT SEWER AND REPLACED BY CONTRACTOR � ASEMENT (TYP)(TYP) SEE DETAIL SHEET 21 / \ y , FOR CONTINUATION SEE SHEET N o. 7 FI NOTES: 1. CONTRACTOR SHALL PROVIDE TEMPORARY BY—PASS LINE AROUND PROPOSED MANHOLE #31 & 32 TO FACILITATE CONSTRUCTION OF DOGHOUSE MANHOLES. FLOW SHALL BE MAINTAINED TO EXISTING PUMP STATION UNTIL FINAL ACCEPTANCE OF TRUNK SEWER AND STARTUP OF STEVENS CREEK PUMP STATION. 2. CONTRACTOR SHALL WORK WITH CHARLOTTE WATER STAFF FOR SHUTDOWN OF PWWTP PUMP STATION. CONTRACTOR IS RESPONSIBLE FOR REMOVING PIPE AND ABANDONING CONNECTIONS TO PUMP STATION. 3. ABANDONED PIPE SHALL BE DISCONNECTED A MINIMUM OF 2—FOOT FROM STRUCTURES. ALL DISCONNECTED LINES SHALL BE PLUGGED WITH WATERTIGHT MASONRY PLUGS. PLUGS SHALL FILL PIPE A MINIMUM OF 18—INCHES IN DEPTH AND CAP THE OUTER WALL BY A MINIMUM OF 4—INCHES. =_� Know what's below. 0111 before you dig. GHD Consulting Services Inc. 222 South Church Street, Suite 400 Charlotte NC 28202 USA T 1 704 302 4910 W www.ghd.com A CITY OF CHARLOTTE DEPARTMENT M O w 00 N Q ti II + V h O = 2 W M L- coo �pO II _ �� 3 _at LIIQ �� EXISTING GRADE NI,JO AT CENTERLINE (APPROX.) N (Wil w V �MJO II 100 YR FLOODPLAIN QI&I_ IV, HAZARDI AREA (TYP) ti IC 3 STREAM CROSSING #6 _ N�'K i- N V �Mp II kc y IQ� A 3Q: cJ rJ 340 64 STREAM BANK STABILIZATION TING R /N = 640.55 PROP. f OUT = 640.35 I I � � �= L PROP. 8" D.I.P. SANITARY SEWER ®2.00% MIN. COVER 3.0' PROP. 12 D.I.P. SANITARY SEWER 3 3 tPROP. 00.75% EX/ST/NG IN = 640.54 PROP. FL /N = 639.82 DROP PROP. f IN - 630.89 PROP. OUT = 630.69 P. E IN = 628.71 IN = 628.96 P. OUT X628.51 (12 ") 0+5 2 `\ \ ► \ FOR CONTINUATION SEE SHEET N o. $4Q°36i'36 "W - 7 x REINFORCED I I I I 22.18'I / STABILIZATION OUTLET (TYP)" \\\� EIS NGPROPbS D 16 ` \ / ) SEE DETAIL I I SHEET 2 ` \ \ ` S7VE�� C � EK I SANITAkY I SEIWE% ` \\ \\ \ \PROPOSD \ I I \ I I \ \ \ S EA TOB TEM OR RY R I \ \ \ \ SILT FENCE (TYP) / / \ \ 0 l � SEE DIT AIL HEET 23 \1�� /CROSSING (TYP) / PLUG AND RE—BEN H / I \ \ + \ ` I \\� ISEE DFS I SHE T 23 PID #19517148 / / MANHOLE AFTER cC4 \ I N61 a 10'50 "W \ ` I \\ \\ \ MECKLENBURG COUNTY TRANSFER TRHAVE ANSFERRED \ DB 24891 PG 862 / / 229.93' I 1 -SA\YR rLUUUt-LAIN PROPOSED Z CREEK TRUNK EWER PROPOSED 12"1zN/TARY SEWER _ nD AREA (TYP) 301 m —\ \ C7 00 UE ansd' C1+00\ wCO 0 SU i TCE J / / / 0 / SCE rcE x TCF PID #19517147 00 STA. A28+10.33 — — a i / / N TCE TC i /STREAM ANK CITY OF CHARLOTTE = Q DB 30613 PG 431 STA. C0+00 00 Tei / / �� STABILIZATION (TYP) PROPOSED 5' — �` l I r' SEE DETAIL T 23 STA. C2f56.22 / O PERMANENT StWER / I PROPOSED 4' D/A. MANHOLE MH -09 7' N EASEMENT (TYP) / STA. C2+29.93 W/WATERTIGHT / PROPOSED 5' D/A. MANHOLE MH -32 w� x TEMPORARY W WA TER FRAME & COVER D/A. MANHOLE MH -31, / . / h EASEMENT (TYP) _ _W WATERTIGHT FRAME & COVER 30' BUFFER LINE \�� k �N�� G \� FRAME &COVER _ � _ � o ws 50' BUFFER LINE ` — - — \��\ \ EXI'9fNG WWTP N31 *2256" W v / PERMANENT SEWER M M _ x TEb(PORARYU STATION MH 26.29' \ / — / C EASEMENT (TYP) h O CONSTRUCTION -1 o � i / � �I� � � � PROPOSED 8" ASEMENT (TYP) II ` SA + � / � EXISIIN� FENCE T 'BE REMOVED N/TARY SEWER---_ / a /ERMANENT SEWER AND REPLACED BY CONTRACTOR � ASEMENT (TYP)(TYP) SEE DETAIL SHEET 21 / \ y , FOR CONTINUATION SEE SHEET N o. 7 FI NOTES: 1. CONTRACTOR SHALL PROVIDE TEMPORARY BY—PASS LINE AROUND PROPOSED MANHOLE #31 & 32 TO FACILITATE CONSTRUCTION OF DOGHOUSE MANHOLES. FLOW SHALL BE MAINTAINED TO EXISTING PUMP STATION UNTIL FINAL ACCEPTANCE OF TRUNK SEWER AND STARTUP OF STEVENS CREEK PUMP STATION. 2. CONTRACTOR SHALL WORK WITH CHARLOTTE WATER STAFF FOR SHUTDOWN OF PWWTP PUMP STATION. CONTRACTOR IS RESPONSIBLE FOR REMOVING PIPE AND ABANDONING CONNECTIONS TO PUMP STATION. 3. ABANDONED PIPE SHALL BE DISCONNECTED A MINIMUM OF 2—FOOT FROM STRUCTURES. ALL DISCONNECTED LINES SHALL BE PLUGGED WITH WATERTIGHT MASONRY PLUGS. PLUGS SHALL FILL PIPE A MINIMUM OF 18—INCHES IN DEPTH AND CAP THE OUTER WALL BY A MINIMUM OF 4—INCHES. =_� Know what's below. 0111 before you dig. GHD Consulting Services Inc. 222 South Church Street, Suite 400 Charlotte NC 28202 USA T 1 704 302 4910 W www.ghd.com A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT CITY OF CHARLOTTE STANDARD CITY OF CHARLOTTE STANDARD CAST IRON FRAME AND COVER. CAST IRON FRAME AND COVER 4" MIN. CLEAR FROM USE BRICK OR CONC. GRADE (BOLT DOWN -WATER TIGHT) JOINT (ABOVE OR BELOW) RINGS FOR ADJUSTMENT OF FINISHED GRADE FLUSH MANHOLES. CUT TO FIT i 9 LF. i D.I.P. 1 /2 PIPE I.D. 6• 2' a N 7" MIN. 21" MAX 7" 24" E16" 5/8" COPPER GROUND ROD C O 5/8" COPPER GROUND ROD O.C. NF 1/4"x2" STAINLESS (SEE NOTES 14 AND 15) isa (SEE NOTES 14 AND 15) STEEL STRAP WITH W N HEIGHT OF RISER TING M.H. 2 ANCHOR BOLTS c AND CONE io SECTION VARIES JOINT � 4� If w N %MIN. of ENLARGED DETAIL STEPS N CORE HOLE FOR INFLUENT D.I.P. o (ON STRAIGHTWALL) m WITH CORING MACHINE AND Z 5" > INSTALL FLEXIBLE RUBBER 5'-000UPLING. Uj (SEE NOTE #5) CUJ NOTES: STRAIGHT WALL OF O.D. PIPE BARRELL M.H. TO BE LOCATED 1. MANHOLE TO CONFORM WITH ASTM C478 EXCEPT AS OVER INFLUENT PIPE MODIFIED BELOW. STANDARD (4'0 M. H.) 2. MANHOLE BASE TO BE REINFORCED WITH A MINIMUM AREA OF #12 COPPER zo 0.20 SQ. IN. PER LINEAL FOOT EACH WAY. WALL REINFORCING A A TRACER WIRE i F TO BE MINIMUM OF 0.12 SQ. IN. PER LINEAL FOOT. EITHER 4'-0' OR 5'-0' TONGUE OR GROOVE SHALL HAVE REINFORCING EQUAL IN i w N AREA TO MINIMUM OF WALL SECTION. SEE NOTE 13 , N W 3. ALL JOINTS SHALL CONFORM WITH ASTM C443. m 4. STEPS TO BE PLASTIC PER CITY STANDARDS. 5. ALL PIPE OPENINGS TO BE NO GREATER THAN 3" LARGER THAN OUTSIDE DIAMETER OF PIPE AND ADDITIONALLY 1/4"x2" STAINLESS / REINFORCED WITH A MINIMUM OF 0.20 SQ. IN. OF STEEL AT 90 DEGREES (ADDITIONAL REINFORCING NOT REQUIRED FOR STEEL STRAP WITH 2 CORED OPENINGS) ANCHOR BOLTS = 6. ALL SURFACES SHALL BE SMOOTH EVEN TEXTURED WITH A B o B MINIMUM OF HONEYCOMB, FINS AND OTHER IMPERFECTIONS. w 7. PENETRATING LIFTING HOLES SHALL BE PLUGGED WITH cn EXPANSION GROUT. w 77�STALLED RESHAPE INVERT /FLEXIBLE COUPLING CAST IN BASE OR 8. INVERTS MAY BE 3600 PSI READY MIX CONCRETE IN LIEU OF IN CORED HOLE WITH 00 SECTION B -B BRICK. PRECAST INVERTS ARE ACCEPTABLE. TAINLESS STEEL COMPRESSION DEVICE. 9. STEPS IN 5' DIAMETER MANHOLES TO BE OVER WIDEST SHELF. O8AND 10" PIPE, INVERTS ARE TO BE 10. 4'0 CONE SECTIONS MAYBE USED WITH 5'0 MANHOLES WITH A 3/4" PIPE OD AT TROUGH, FOR 12" AND 5'-4" TRANSITION SECTION PLACED DIRECTLY BENEATH THE 4 CONE. LARGER PIPE, PROVIDE FULL INVERT AS 11 MANHOLE SECTIONS SHALL BE DESIGNED FOR H-20 SECTION A -A SHOWN. THE SHELF SHALL SLOPE 2" FROM LOADING. THE MANHOLE WALL TO THE TROUGH. 12. MINIMUM HEIGHT FOR CONCENTRIC CONES ON MANHOLES WITH BOLT DOWN F&C IS 32". NOTES: 13. COPPER TRACER WIRE TO BE WRAPPED AROUND OUTSIDE OF MANHOLE AND UP TO CONNECT WITH GROUND ROD. 14. 5/8" COPPER GROUND ROD CAST IN MANHOLE 1" BELOW TOP 1. PIPE FOR INSIDE DROP SHALL BE SDR 35 PVC CONFORMING TO ASTM STEP IN CENTERLINE OF STEP, GROUND ROD NOT TO 2. SPECIFICATION D3034. BOTTOM BEND TO BE 90' SHORT BEND, BELL SPIGOT, OF SDR 35 PROTRUDE PAST INSIDE EDGE OF STEP. PVC. SPIGOT OF BEND TO REST DIRECTLY ON EXISTING SHELF. 15. CONNECT TRACER WIRE TO GROUND ROD WITH GROUND ROD CONSTRUCT MASONRY THROUGH FROM DROP EFFLUENT TO MAIN CLAMP WITH SS SCREWS. WRAP ALL EXPOSED METAL WITH Z)r CHANNEL. RUBBER ELECTRICAL SPLICING TAPE. 16. TRACER WIRE IN 1/2" PVC CONDUIT ATTACHED TO MANHOLE. 3. NOTCH BELL OF PVC DROP TO ACCEPT D.I.P. SPIGOT AS SHOWN. 4. LOCATE STRAPS AT PIPE BELL AND ABOVE BELL OF 90' BEND AS SHOWN. ADD EXTRA STRAPS AS NECESSARY TO MAINTAIN MAXIMUM SPACING OF TEN FEET. 5. HOLE IN MANHOLE WALL TO BE MADE WITH A CORING MACHINE. INSTALL FLEXIBLE RUBBER COUPLING. 6. CORE HOLE SHALL NOT ENTER CONE SECTION. 2" FALL 7. STEPS SHALL BE RELOCATED IF THEY CONFLICT WITH INSIDE DROP. (TYP.) I INSIDE DROP DETAIL PRECAST MANHOLES 4' & 5' DIAMETER NOTES: 1. MANHOLE BASE SHALL BE 4000 PSI CONCRETE PLACED ON = A A UNDISTURBED EARTH AND MAY BE PLACED AGAINST SHAPED i' BANKS IN LIEU OF FORMS. 2. CONTRACTOR SHALL NOT CUT THE EXISTING SEWER PIPE UNTIL PERMISSION IS GRANTED BY THE ENGINEER OR SRU INSPECTOR - AFTER FINAL PROJECT APPROVAL. 3. WRAP OUTSIDE MANHOLE SEAMS (JOINTS) WITH WIDE BUTYL TAPE. 4. MANHOLE TO CONFORM TO CITY STANDARDS AND (7)= SPECIFICATIONS FOR PRECAST MANHOLES. �10 5. ALL MANHOLES ARE REQUIRED TO BE VACUUM TESTED. 0 I 1-1/4" 6. 4' INSIDE DIAMETER MANHOLES SHALL HAVE 5" THICK WALLS rn 5' INSIDE DIAMETER MANHOLES SHALL HAVE 6" THICK WALLS 7. MANHOLES MUST NOT HAVE ANY LARGE CHIPPED AREAS, PLAN STAINLESS STEEL BROKEN AREAS, CRACKS, OR EXPOSED REINFORCEMENT, OR NUTS & BOLTS OTHER DEFECTS. DEFECTIVE MANHOLES WILL NOT BE ACCEPTED. V\8/ O BUTYL MASTIC BETWEEN A MANHOLE AND FRAME &COVER PRE -CAST RINGS (WHEN NEEDED) MAXIMUM OF 11 1/2- /2"A INCLUDING BUTYL MASTIC A- BUTYL RUBBER SEALS IN JOINTS 10-3/4- 12" = =L_\ 5" MIN 6" MIN \_.' CONCRETE BLOCK COPOLYMER POLYPROPYLENE PLASTIC PIPE DIA. CONCRETE MONOLITHIC POURED 1/2" GRADE 60 STEEL REINFORCEMENTZ 8" MIN UNDISTURBED SOIL OR COMPACTED SECTION AA WASHED STONE WHERE POOR SOIL SECTION A -A CONDITIONS EXIST 5-3/4" CHARLOTTE CHARLOTTE WATER THIS STEP TO BE DRIVEN INTO W6TER TAPERED HOLES IN PRECAST CHARLOTTE, NORTH CAROLINA MANHOLE SECTIONS. DO NOT USE AS A GROUTED -IN STEP. DOGHOUSE MANHOLE 7030700047-17- 503 1000 LB. PULL OUT TEST REPORT STEVENS CREEK REQUIRED ON EACH STEP. Job No. File No. Scales TRUNK SEWER PHASE I PLAN NTS PROFILE PLASTIC STEP CORED HOLE MANHOLE DETAILS (SHEET 1 OF 2) Vert. NTS DRIVEN IN PLACE As Built Date Of A 2/16 TED FINAL DESIGNSheet L. ASSOC JEM TED MEB 5/4/18 16 26 No. Date By Revision Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT 5/8"x2 1/2" EXPANSION ANCHOR BOLTS ON BOTTOM BRACKETS. 5/8"x4" EXPANSION ANCHOR BOLTS ON TOP BRACKET. BIRD/INSECT SCREEN Ell% YLAANGLEAS REQ'D, TO QUARELY ONE TOP BRACKET ONLY 11 1/2- 1 /2"> 1 /2" a 1/2- > 1/2- 1 /2"1 1 /2" I I I I 11/16"0 HOLES BRACKET FABRICATED DRILLED AS SHOWN FROM 1/4" STEEL PLATE PIPE BRACKET PIPE BRACKET (SEE THIS SHEET)- WASHER HEET)- WASHER PLATES TO PLUMB VENT 1 4" 1/4" PLATE A � I LJ A SECTION A -A ACCORDING TO THE TYPE OF PRECAST MANHOLE. WASHER SPACERS MAY BE REQUIRED ON LOWER BRACKETS. 1/4' 5"0 STEEL PIPE 1_Z4- 0 W or a CIT -r 0 9" I [ 1 4" PLUG WATERTIGHT FRAME AND COVER (BOLTED DOWN) STEPS AND VENT INSTALLED ON STRAIGHT WALL OF M.H. PRECAST CONCRETE MANHOLE MANHOLE VENT DETAIL NOTES: 1. VENT SHALL BE ON CREEK SIDE AND POINT DOWNSTREAM. 2. VENT AND BRACKETS SHALL BE PAINTED PER SPECS. 3. AVOID PLACING PIPE BRACKET AT MANHOLE JOINTS OR STEPS. 4. ANCHOR SLEEVE, THREADED STUD AND NUT SHALL BE STAINLESS STEEL OR GALVANIZED STEEL. 5. ROTATE STRAIGHT WALL OF MANHOLE TO CREEKSIDE. w O V a om z za X Y im ( 0"-72" 1 60" 1 3 72"-84" " )VER 84" 72" 3 GROUND LEVEL N 4" TOP VIEW 4- L A B E L Co TYPE "A" GROUN[ TOP VIEW 2.956" io LO rn R. TYPE "B" NOTE: 1. ALL MARKER POSTS SHALL BE INSTALLED PER MANUFACTURER'S RECOMMENDATIONS. MANHOLE VENT DETAIL C P A S I U E P T W E I E L 0 R I N N E Know what's below. Call Wore you dig. LABEL DETAILS CHARLOTTE CHARLOTTE WATER W6TER CHARLOTTE, NORTH CAROLINA 7030700047-17-503 Job No. File No. Scales PLAN NTS PROFILE Hor. NTS Vert. NTS STEVENS CREEK TRUNK SEWER PHASE I MANHOLE DETAILS (SHEET 2 OF 2) As Built Date A 2 16 TED FINAL DESIGN Sheet Of L. ASSOC JEM TED MEB 5/4/18 17 26 No. Dote By Revision Surveyed By Designed By Drawn By Project—Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT 3/4" LETTERS 1" LETTERS (RECESSED FLUSH) nRy 0 1" VENT HOLE (RECESSED FLUSH) 3/4" LETTERS IRO /y 1" ARIAL TEXT ®j;� 5/8" ARIAL STYLE TEXT NETRATING JpRT EI RpN wpRks �, ®� s� JpRDAN Wpb°�®RIOT (RECESSED FLUSH) EP �s T E®�� TF PICKNHOLESON 1 1" LETTERS 1 5/8" OT T E �� S �PR� wA 1 ARIAL TEXT G ° O T E �/—DETAIL GAP CAM LOCK 2 CORED �0 .9 (RECESSED FLUSH) P ICKBARS 5/8" ARIAL STYLE TEXT HOLESNETRATING -9� PICK HOLES � 1 5/8"� "WARNING SEE ASSEMBLY -z- CAM LOCK v WARNING � v ANITARY (2) CORED DO NOT ENTER SEE ASSEMBLY SANITAR , 1/2" DETAIL EWER DO NOT NT (2) - LIFTING BARS PICKBARS SEWER (2) - NON PENETRATING PICK HOLES � O (2) -NON PENETRATING PICK HOLES � 1 1/2-1 1 1 /2" "-11x4" � � 3/4" LETTERS TYPE 304 S.SBOLT HEX . 1 1/2- 4U 1 1/2"1 USF CAMLOCK WASHER ,A /2n (RECESSED FLUSH) 1 5/8" HEX HEAD BOLT 1 /16"x5/8"x1 1 /2" WASHER � � 3/4" LETTERS / s,�Q' q T N� E� S.S. TYPE304 RUBBER 5/8" ID 1.50 OD �� TYPE 304 S.S. C, s q �Q A s �� (RECESSED FLUSH) �C D O N®� A R Y s Do NO R Y E ON U.B. MADE i N USA 1" VENT HOLE ON U.S.�'° — = 2 3/8" 1 1/8-- BOSS LOCK LUG MADE IN USA / 26" 6 10/4" 4" 1 1/2- 0 26" 1 1/2" 26" 22 " — 3/8" 0 26" NUT HEX 5/8"-11 13/16" 1 1/2" TYPE 304 S.S. NYLK 15/16" � 13/16" � 6 1 /4" 15/16 " I 3 1/4- O 0 3 13/16" I = 3 1 /4" = O —� �� _ '"� 2 1/8- NUT HEX JAM 5/8"-11 TYPE 304 S.S. 3 1 /8" 1 /2rr 1 15/16" �� 5 3/16 1 5/8" 3 1/8- 1 /2" � 1 15/16 " 0 22 13/16" NEO NE 2 1/8" " GASKET 1 3/8" 0 22 13/16" 1 1/2" I� 5 3/16"� 3/16" 0 25 01" VENT HOLE - 15/16" 9/16" 15/16" I 3 13/16" O.D. OF GKT GROOVE T i I I � 011/16" 1 3/8" 6 1/2" 1/2" 9/16" 5/8" TYPE 304 5/8" TYPE 304 1/2" 5/8" TYPE 304 MACHINED S.S. ROD SURFACE S.S. ROD MACHINED SURFACE EAST JORDAN IRON WORKS S.S. ROD 3 16 DOVETAIL / GROOVE MACHINED 1 2rr '1800 /)��t/8"TYPE 304 EAST JORDAN IRON WORKS USF NR USF NL SURFACE .2400" MACHINED S.S. ROD SURFACE DATE 5/8" 3/4" 1 1/4- 1040C 2 1 /4" UT I 7/16" MO/DA/YR X PROD. NO. DATE 5/8" 3/4" 1 1/4- 3/16- 1040AGS 2 1/4- 7/16" lom " rr MO/DA/YR X 1 3/8 1 PROD. NO. CLASS 35 1 3/8" ASTM A48 CL35B 1 �� 0 7/8 CLASS 35 " CAM LOCK ASTM A48 CL35B -- -- -- -- 1" VENT HOLE HOLE ® 22" " 3/8 �- 5/8"- 5/16" ----- _ — - /4"" 3/grr �J L " DOVETAIL 180 rr [:.240" 1 1/8 3 4" / GROOVE GROOVE PICK HOLE DETAIL PICK HOLE DETAIL PICK HOLE DETAIL PICK HOLE DETAIL TYPE 1 24—INCH MANHOLE COVER (VENTED) TYPE 3 24—INCH MANHOLE COVER WATERTIGHT GASKET CAMLOCK (SOLID) (4)-0 1" ANCHOR g S S d � HOLES ONA b' S .n �Sn Ni �,o (4) - 0 1" ANCHOR ST JpRDAN IRON WpR P Ks n 0 33 3/4 B.C.D. � ��� b�V HOLES ON A E 0 31" B.C.D. / 0 0 s b S 0 (4)-0 1" ANCHOR / � HOLES ON A s �� b� 0 32 3/4" B.C.D. Y o 0Dz V) p w 0 2 0 C) o MACHINED r v 7) MACHINED SURFACE 0 0 cin SURFACE 0 0 1 1 /2" w Lp J 1 1 /2" EAST JORDAN IRON WORKS FMADE O,q T E MADE I N U S A IN USA MACHINED FRAME SURFACE MACHINED OO SURFACE 1 5/8" 1 1/2- Oq iE 27 1/4" FRAME 1 1/2" 34" I 1" 26 1/4" 1 1/2" 1 1/2" � n 26 1/4" 1 1/2 MACHINED 27 7/16" 1 SURFACE 26 1/4- FRAME 24" 4" 24" 1/2"A 27 15/16" 36r' 26 1/4" 4" 24" 26 1/4" 1 1/2" 36" 24" 27 1/4" 5/8» I 1 4 1 1 /2" F 27„ 4" I —T-5/8'5/8" CHARLOTTE CHARLOTTE WATER W�TER „ 11/2” CHARLOTTE, NORTH CAROLINA 36 26 1/4" MACHINED SURFACE 7030700047-17- 503 Job No. File No. STEVENS CREEK TYPE B 24—INCH MANHOLE FRAME 4 INCHES TALL TYPE C 24—INCH MANHOLE FRAME 4—INCHsales PLAN NTS TRUNK SEWER PHASE l TALL INVERTED — REVERSIBLE (CAST IN) PROFILE Hor. NTS NTS 24 IN. MANHOLE FRAME Vert. AND COVER DETAILS As Built Date A 2/16 TED FINAL DESIGNSheet Of L. ASSOC JEM TED MEB 5/4/11 1 $ 26 No. Date By Revision Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT MACHINED 0 1" VENT HOLE SURFACE 1" LETTERS (2) CLOSED (RECESSED FLUSH) � ORpTA PICKHOLES R0 ry w0R MACHINED TSURFACE 1" LETTERS T(RECESSED FLUSH) (2) CLOSED `pTTE-Wq�� G®0�R 1 5/8- Pss � s E 7- PICKHOLES 7" k 7/8 1 5/8" r-VENT HOLE \.O 1" DIA VENT VENT --I- ® CAM LOCK 7/16 " 1` (2) CAMS C.) �J (SEE DETAIL) CAM LOCK 8" PQ- �HOLE HOLE,Z.o .. V (2) CAMS DSEE ETAILSSEMBLY O DSEE ETAILSSEMBLY7/16" ® ®� ® (SEE DETAIL) 0 1/2"— WARNING g 7 g" / x of � 0 SANITARY �0 9" 32" �O ® ® 1 2" / 1*0 T SANITARY DO NOT ENTE �w SEWER WARNING 1 8 7/8" DO NOT ENTER,_� \I- 9" i 32" o O � ® ®® ®®® ® ®® ® N — "� o SEWE ® 1" ARIAL STYLE TEXT TYP. o " / .. 1 /4 1 3/4" LETTERING G „ ISTYLE j o 1 /4" ®® 5/16" RECESSED I v/� TEXT TYP. ® -V7�� 5/16" 'A �/ S,q ^n� NOTARY SG ORS GASKET NEOPRENE RUBBER 1 1 4" / (3 MACHINED DO N ® ® ® ORS GASKET SqN� �� 3 1/2" 1 1/4" /VG '( / " (2)-NON MADE IN U.S.P• PENETRATING 60 DUROMETER 1" LETTERING SURFACE M q ° s ' RECESSED wVv NEOPRENE T S RUBBER (2)-NON TA 60 DUROMETER Y D0 ND 1 3/4 LETTERING MACHINED M a RECESSED SURFACE a ° s PICKHOLES 1 1/2" I F� PENETRATING MADE IN U - s • P � E ' " 1" LETTERING 32 " 3 1/2" 27 3/4" PICKHOLES II 1 1/2 F� RECESSED 1 1/2" 28 5/8" 3 1/2" TYPE 1 X 3 1 /2" LG 5/8" I.D. 1 1 /2" O.D. 5/8" 1 1 /2" TYPE SS 32" 1/2" 27 3/4" " HEX TYPE 304 SS FLAT WASHER BOLT BOLT 1 1/2" 28 5/8" 5/8"-11 X 3 1 /2" LG 5/8" I.D. 1 1 /2" O.D. 5/8" 1 1 /2 3 1/2" TYPE 304 SS TYPE 304 SS FLAT WASHER _ _ F3 USF CAMLOCK 5/8" HEX HEAD BOLT " " 5/8 I.D. 1 1/2" O.D. r �� RUBBER WASHER F7T _ = USF CAMLOCK HEX 5/8" HEX HEAD BOLT BOLT 5/8" I.D. 1 1/2" O.D. RUBBER WASHER F J I ! MACHINED SURFACE ALL GRADE S.S. TYPE 304 3 1/2"-J5/16" MACHINED ALL GRADE S.S. MACHINED TYPE 304 -- 5/16" CAM LOCK ` BRONZE 1/4" 9 SURFACE LOCK LUG CAM LOCK SURFACE VENT HOLE 3 1/2 " MACHINED �� OCKBRONZLUG 1/4 9 SURFACE - 45, - 21/2" NEOPRENE 5/8-11 HEX GASKET I \ I — 2 1/2" NEOPRENE GASKET = ) JAM NUT TYPE 304 SS 45' = HEX 3/8" � I JAM N TYPE 304 SS AM N G s� WELD ON JAM NUT OR 3/8" 11 /16�� TYPE 304 SS PEEN END THREADS ON BOLT 5/88-11 NUT NYLOK G WELD ON JAM NUT OR 2 1/8" 11/16" � � \ 2 1 /8" 22'5' ORS GASKET 5/8-11 TYPE 304 SS PEEN END THREADS ON BOLT NYLOK NUT VENT HOLE-- 2 1/4" 22.5' ORS GASKET _ \ RUBBER v 4' 60 DUROMETER 3/4" 5/8" 1 1 /4 " 2 1 /4" 7/16" 1480GS A CLDI 1 3 8 o O / 1" PROD. NO. NEOPRENE r RUBBER 5/8" 4__ r 60 DUROMETER3/4" 1 1/4" GS 7/16" 1480ClCLDI 3/8" 1" PROD. NO. _ MO/DY/YR X —_ -- ----TT 3/16" II —1 MO/DY/YR X 0 7/8" CAM LOCK — -L— - 3/16„ \ -----� �-- 09HOLE ® 0 28 5/8" 3/8" 5/8" 5/16" 180" 3/4" 0 7/8" CAM LOCK HOLE ® 0 28 5/8" 3/8" 5/8 " F I 3/4" CLASS 35 GRDOVETAIL GROOVE .240 240" DI 80-55-06 — 18" 5/16" .180" f� " CLASS 35 3/16" DOVETAIL PICK HOLES DETAIL PICK HOLES DETAIL GROOVE DI 80-55-06 PICK HOLES DETAIL PICK HOLES DETAIL TYPE 4 30-INCH MANHOLE COVER VENTED, GASKET, CAMLOCK (VENTED) TYPE 5 30-INCH MANHOLE COVER WATERTIGHT, GASKET, CAMLOCK (SOLID) 31 b4 31 ba (6) - 0 1" ANCHORNV(11:lor lsb3 O / HOLES ONA 0 37 1/2S B.C.D.4� \ 6, // \\ s (1CHOR �o 0\� � // � 2J- HOLES 0N A y / (6) - 0 1" ANCHOR (6) // 0 35 5/8" B.C.D. �o s HOLES ON A 0 37" B.C.D. ICU ? �� O If /� o 0 \\ \� MACHINED /� 0 SURFACE O z 0 o \\ // ^0 \ MACHINED SURFACE FRAME--\20 / / O L \\ FRAME N \ \ / MACHINED J MACHINED SURFACE FOV NDRY op1�Q11 SURFACE 0 1 5/8F 1 1 1/2 • S (� FOUNDRY MADE IN USA O MO/DAY/YR 7/16" 40 3/4" 32 1/4" Ll 1/2- MACHINED SURFACE MACHINED SURFACE 38" 32 1/4" 30" 1 1/2" 1 1/2" 11/16" 30" 33 1/4" FRAME 32 1 /4" 33 1/4- 1 1/2" � � 4" I 1 1/2" 1 " 4" 32 3/16" 1 1/2" 4" 321/4" 1 1/2" 5/8" 4 1/2" 32 1/4" 33 1 4 /" CHARLOTTE CHARLOTTE WATER 30" 32 1/4" 2 9/16" 30" 33 15/16" V% �T E R WCHARLOTTE NORTH CAROLINA 9 " 40 3/4 40 3/4" 7030700047-17-503 STEVENS CREEK Job No. File No. Scales PLAN NTS TRUNK SEWER PHASE I TYPE E 30-INCH MANHOLE FRAME 4-INCH TYPE D 30-INCH MANHOLE FRAME 4-INCH TALL PROFILE TALL INVERTED - REVERSIBLE (CAST IN) Hor. NTS 30 /N. MANHOLE FRAME Vert. NTS AND COVER DETAILS As Built Date A 2/16 TED FINAL DESIGNSheet Of L. ASSOC JEM TED MEB 5/4/18 19 26 No. Date By Revision Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT 1900 INITIA PIF PIPE SPRIN HAUNCI BEDDIN, FOUNE SUBGRADEJ NOTES: 1. FOUNDATION MATERIAL ONLY REQUIRED WHEN UNSUITABLE SUBGRADE MATERIALS ENCOUNTERED. 2. SEE SPECIFICATION 02223 (BACKFILLING) FOR MATERIALS REQUIRED. TYPICAL TRENCH DETAIL STRAIGHT THROUGH 4 -WAY JUNCTION FORM BENCH WITH 4000 PSI CONCRETE 4ANHOLE WI RIGHT ANGLE 3 -WAY JUNCTION CONCRETE BASE SECTION :l�:T�P► SLOPE BENCH TO CHANNEL ® 1% PROPOSED MANHOLE NOTES: 1. FINISH ALL CHANNELS AT PROPER GRADE AS TO ALLOW SMOOTH AND UN -OBSTRUCTED FLOW ALL INVERTS TO BE FLUSH WITH THE INSIDES. MINIMUM CHANNEL SLOPE = 0.2% FLOW CHANNEL AND BENCH DETAIL CONDITION SCHEMATIC REQUIREMENTS CARRIER PIPE WL NCDOT THICKNESS I (INCHES) A. WATERLINE AND SEWER LINE PIPE LENGTHS TO BE CENTERED AT (INCHES) THOMPSON RD CROSSING. EACH LENGTH OF PIPE WATERLINE MORE THAN IS TO BE 10' MINIMUM. ABOVE 18 INCHES 0.250 SEWER LINE SL A. WATERLINE AND SEWER LINE PIPE SL LENGTHS TO BE CENTERED AT CROSSING. EACH LENGTH OF PIPE. B. COMPACTED SELECT FILL OR WASHED SAND TO THE CENTERLINE OF SEWER LINE MORE THAN EXISTING UTILITY PIPE. ABOVE 18 INCHES WATERLINE WL BACKFILL WL - WATERLINE SL - SEWER LINE, SANITARY OR STORM D PIPE BEDDING D -OUTSIDE DIAMETER OF PIPE IN NO CASE SHALL PIPES BE CLOSER THAN 18" APART. DISTANCES ARE MEASURED BETWEEN OUTSIDES OF PIPE. D PLUS 2' END CLOSURE SEE DETAIL BELOW DRAINAGE GRAVEL (10 CF OF STONE) WATERMAINZSEWER CROSSING SPIDER SUPPORTS OR APPROVED EQUAL SLOPE TO DRAIN PROVIDE" WEEP HOLE AT LOW POINT OF CASING ENCASEMENT PIPE r -PROPOSED SEWER MAIN RESTRAINED JOINT DIP CARRIER PIPE 45* ,'ARRIER PIPE _q STEEL SPIDER SUPPORTS ENCLOSE ENDS WITH 8" BRICK MASONRY (SEAL WITH NON -SHRINK GROUT AS 90, NECESSARY) END CLOSURE SECTION SECTION INIMUM SIZE AND THICKNESS STD. FOR ENCASEMEN PIPE LOCATION CARRIER PIPE CASING PIPE NCDOT THICKNESS w 1 (INCHES) (INCHES) (INCHES) THOMPSON RD 16 30 0.312 THOMPSON RD 12 24 0.250 STEEL ENCASEMENT PIPE NOTES: 1. REFER TO APPLICABLE PERMIT FOR MINIMUM REQUIREMENTS GOVERNING HIGHWAY UNDERCROSSINGS. 2. STEEL "SPIDERS" SHALL BE USED FOR SUPPORT OF THE CARRIER PIPE WITHIN THE ENCASEMENT (CASING) PIPE. 3. A MINIMUM REQUIREMENT OF 2 SPIDERS PER JOINT OF CARRIER PIPE SHALL BE REQUIRED. 4. SPACING OF SPIDERS WILL BE DICTATED BY THE LENGTH OF CASING PIPE AND NUMBER OF JOINTS OF CARRIER PIPE. 5. THERE SHALL BE NO WELDING OF CASING UNDER PAVEMENT. CASING PIPE WITH SPACERS STAINLESS STEEL TAKE-UP CLAMP 1 FOR PIPE 14.3" OD OR SMALLER 2 FOR PIPE 14.3" OD OR LARGER V SLOPE TO CHANNEL STAINLESS STEEL POWER SLEEVE RING OR APPROVED EQUAL CHANNEL - o GASKET EXISTING BENCH NOTES: 1. CORE DRILL ENTRANCE HOLE IN MANHOLE BARREL, BASE AND/OR BENCH FOR REQUIRED PIPE CLEARANCE. PER MANUFACTURERS RECOMMENDATIONS. 2. WATERTIGHT PIPE TO MANHOLE BOOT SEAL REQUIRED FOR ALL CORE DRILLED ENTRANCE HOLES IN MANHOLE BARREL AS SHOWN. CONNECTION TO EXISTING MANHOLE EXISTING PIPE CROSSING (SEE1'- WATER MAIN CROSSING DETAIL FOR CONCRETE ENCASEMENT) N Q J E: Y 0 a m o z 0 N w a CL 101 1 J 1 I SELECT FILL L_ Y ao J w 1 m� Y D C 0 Q a d _� N TRENCH BOTTOM PIPE CROSSING SUPPORT DETAIL mmm PIPE VARIES WITH / SLOPE PIPE BEDDING PROPOSED SEWER R EXIST. OR FINISHED GRADE 1�, MINIMUM 4' MIN. COVER AT T 22 -1/2 -BEND (PVC, DIP OR CISP.) COMPRESSION JOINT SEALER SEWER TAP SADDLE EPDXY SEALANT AS RECOMMENDED BY TAP SADDLE MANUFACTURER VITRIFIED CLAY, PVC OR DUCTILE IRON PIPE. NOTES: 1. THE OPENING PIPE SHALL BE CUT WITH A TAP MACHINE ONLY. 2. THE TAP SHALL BE MADE IN THE UPPER HALF OF THE PIPE AT 45' FROM THE HORIZONTAL. 3. MAXIMUM SIZE TAP SHALL BE FOUR INCHES. 4. TEE & BEND TO BE FULLY ENCASED WITH #67 CRUSHED STONE. 5. SDR 35 PVC LATERAL PIPE REQUIRE TYPE III GRANULAR BEDDING. 6. MIN. CLEAR TO PIPE JOINT ON MAIN SHALL BE 1'-0". 7. THE LATERAL MUST BE INSTALLED PERPENDICULAR TO THE MAIN. 8. IF THE LATERAL HAS LESS THAN 3' OF COVER, THE LATERAL MUST BE D.I.P. 4" LATERAL (TAP SURFACE FLOW DIVERTED BY SWALE 0 P� SURFACE FLOW DIVERTED BY SWALE SEED AND MULCH W/— SURFACE BINDER AGGREGATE BED OVER GEOTEXTILE FILTER CLOTH AGGREGATE APPROCH 1: 5 (V: H) MAXIMUM SLOPE ON ROAD SURFACE FLOW DIVERTED BY SWALE SURFACE FLOW DIVERTED BY SWALE \--NEW ROAD GEOTEXTiLE FILTER CLOTH ORIGINAL STREAM BED AGGREGATE BED OVER TEMPORARY FORD CROSSING CHARLOTTE CHARLOTTE WATER W6TER CHARLOTTE, NORTH CAROLINA 7030700047-17-503 Job No. File No. Scales PLAN NTS PROFILE Hor. NTS Vert. NTS As Built Date FINAL DESIGN L. ASSOC JEM Revision Surveyed By Designed By STEVENS CREEK TRUNK SEWER PHASE I STANDARD SEWER DETAILS (SHEET 1 OF 2) Sheet Of TED MEB 5/4 18 120126 Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT GRAVITY SEWER MAIN & MANHOLE MARKER SECTION VIEW 4'-6" 2'-6- 12* HOLE FILLED' WITH CONCRETE 5/8" COPPER GROUND ROD. CAST IN OR CORE IN MANHOLE 1" BELOW STEP IN CENTERLINE OF STEP. DO NOT PROTRUDE PAST INSIDE EDGE OF STEP. FLOW PLASTIC GREEN MANHOLE MARKER LABELED SEWER MH (SEE NOTES) SEWER LATERAL ♦ _ _ _ - - C- GROUND ROD CLAMP SECTION VIEW 1 6-[-- 12" MIN. I TRACER I CONNECT EACH TRACER WIRE TO GROUND I ROD WITH GROUND ROD CLAMP WITH STAINLESS STEEL SCREWS (SEE DETAIL ABOVE). WRAP ALL XPOS D M TA WITH E E E L RUBBER ELECTRICAL SPLICING TAPE. NO. 12 GAUGE SOLID ��COPPER TRACER NARES (TYP.) (SEE NOTES) ALL VERTICAL WARE SHALL BE PLACED IN 1" ID PVC CONDUIT N0 12 GAUGE SOLID (CO�PER E NOTES ,SSEEWER ADDLE )TAP FLOW WRAP EACH TRACER WARE AROUND OUTSIDE OF MANHOLE AND CONNECT TO GROUND ROD SEWER MAIN STEEL SCREWS (TYP.) SPLICE To MAIN TRACER WARE FOR NEW SEWER NEW SERVICE ON EXISTING MAIN MAGNESIUM ANODE (1 LB. MIN.) REQUIRED WHERE NO TRACER WIRE IS LOCATED ON SEWER MAIN NOTES: 1. TRACER WIRE SHALL BE AWG NO. 12 GUAGE SOLID COPPER WITH 30 MILS GREEN HDPE INSULATION. 2. FOR GRAVITY MAIN AND OR LATERAL INSTALLATIONS LESS THAN 8 FEET, THE TRACING WIRE SHALL BE ATTACHED TO THE PIPE. TRACER WIRE SHALL BE LAID FLAT AND SECURELY AFFIXED TO THE PIPE AT 10 FOOT INTERVALS USING ZIP TIES. FOR GRAVITY MAIN AND OR LATERAL INSTALLATION DEEPER THAN 8 FEET, THE TRACING WIRE SHALL BE ATTACHED TO THE PIPE AND PLACED AT A DEPTH OF 4 TO 5 FEET DIRECTLY ABOVE THE SEWER PIPE. TRACER WIRE SHALL BE PLACED IN CONDUIT WHEN NOT PLACED AT THE SEWER PIPE. (SEE CLTWATER STD. DETAIL TS1) THE WIRE SHALL BE PROTECTED FROM DAMAGE DURING THE EXECUTION OF THE WORK. NO BREAKS OR CUTS IN THE TRACER WIRE OR INSULATION SHALL BE PERMITTED. 3. WHERE LATERAL TAPS ARE MADE BY SERVICE SADDLES, THE TRACER WIRE SHALL NOT BE ALLOWED TO TO BE PLACED BETWEEN THE SADDLE AND MAIN. 4. SPLICES IN THE PRIMARY TRACER WIRE ALONG THE SEWER MAIN SHALL INCLUDE 3 FEET OF SLACK WIRE ON EACH SIDE OF EACH SPLICE. 5. FOR INSTALLING A NEW LATERAL ON AN EXISTING MAIN WITH TRACER WIRE, ONLY SPLICE TO EXISTING WIRE WITH 3 FEET OF SLACK ON NEW LATERAL. 6. MANHOLE MARKERS SHALL BE PLACED ADJACENT TO MANHOLES AT THE DISCRETION OF ENGINEER OR ENGINEER'S REPRESENTATIVE. FLOW NO. 12 GAUGE SOLID COPPER TRACER WIRE (TYP.) NEW SERVICE ON EXISTING MAIN MAGNESIUM ANODE (1 LB. MIN.) REQUIRED WHERE NO TRACER WIRE IS LOCATED ON SEWER MAIN LATERAL WRAP TRACER WIRE AROUND OUTSIDE OF NO.12 GAUGE SOLID COPPER MANHOLE AND CONNECT TRACER WIRE (TYP.) TO GROUND ROD EXISTING GRAVITY MAIN SERVICE CONNECTION zI SECTION VIEW wla `wyli w J WI PER REHAB 0 i rDETAIL n 0: 1 EXTEND TRACER WIRE M-� JUST ABOVE CLEANOUT PLUG. PROVIDE 24" NEATLY COILED -" WARE IN BOX. ALL VERTICAL WIRE SHALL BE PLACED-/ IN 1/4" OR 3/8" ID CONDUIT SDR 9 PEX TUBING - ASTM F876 (TYP.) NO. 12 GAUGE SOLID COPPER ¢ TRACER WARE (TYP.) MIN. FASTEN TRACER WIRE TO PIPE WITH ZIP TIES AROUND THE CIRCUMFERENCE OF PIPE AT 10' INTERVALS (TYP.) VALVE BOX ASSEMBLY (SEE CLTWATER STD. DETAIL) `STEEL REBAR SIZE #3 OR #4 CONCRETE PAD (SEE CLTWATER STD. DETAIL) NOTES: 1. THE TRACER WIRE SHALL BE CONTINUOUS TO THE GREATEST EXTENT POSSIBLE. WHERE SPLICES ARE NECESSITATED IN THE WIRE, THE SPLICES SHALL BE SECURELY BONDED TOGETHER WITH AN APPROVED INDUSTRIAL CONNECTOR TO PROVIDE ELECTRICAL CONTINUITY. CONNECTOR SHALL BE COPPER AND INSULATION SHALL BE REPAIRED TO SEAL OUT MOISTURE AND CORROSION AND SHALL BE INSTALLED IN A MANNER SO AS TO PREVENT ANY UNINSULATED WIRE EXPOSURE. (SEE CLTWATER STD. DETAIL TS1) 2. THE CLEANOUT AT THE RIGHT OF WAY AND OR EASEMENT SHALL SERVE AS THE TEST PORT. 3. SPLICED CONNECTIONS SHALL BE ALLOWED BETWEEN THE MAIN LINE TRACER WIRE AND THE LATERAL TRACER WIRE. 4. FOR NEW SEWER TAPS ON EXISTING MAINS VOID OF ANY TRACER WIRE, PROVIDE A 1 LB. MAGNESIUM ANODE FOR THE TRACING WIRE TERMINATION AT THE POINT OF THE NEW TAP ON THE EXISTING SEWER MAIN. PLACE ANODE AT BOTTOM EDGE OF TRENCH AWAY FROM MAIN & LATERAL. 5. PRIOR TO ACCEPTANCE (POST PUNCH LIST) EACH WIRE SEGMENT SHALL PASS A CONDUCTIVITY TEST, WITNESSED BY THE ENGINEER OR ENGINEER'S REPRESENTATIVE. TAPE TRACER WARE TO PIPE WITH 2" WIDE PVC \ TAPE AROUND THE CIRCUMFERENCE OF PIPE AT 10' INTERVALS (TYP.) GRAVITY SEWER MAIN PLAN VIEW SPLICE SEWER MAIN FLOW -ALL VERTICAL WIRE SHALL BE PLACED `NO. 12 GAUGE SOLID COPPER IN 1" ID PVC CONDUIT TRACER WIRE (TYP.) OUND ROD MANHOLE NOTES: 1. TRACER WIRE SHOWN AWAY FROM PIPE FOR CLARITY. TRACER WIRE SHALL BE INSTALLED IMMEDIATELY ADJACENT TO THE SEWER PIPE. TRACER WIRE SHALL BE FASTENED TO THE PIPE WITH ZIP TIES AT 10 FOOT INTERVALS. 2. TRACER WIRE SHALL BE SOLID COPPER NO. 12 GAUGE WITH 30 MILS GREEN HDPE INSULATION. FLOW TRACER WIRE FOR GRAVITY SEWER DEEPER THAN 8 ET SECTION VIEW SEWER SEWER MANHOLE FINISHED GRADE FINISHED GRADE f MANHOLE SPLICE CONDUIT GRAVITY SEWER MAIN PIPE - LESS THAN 8' DEPTH TRACING WIRE SHALL GRAVITY SEWER MAIN GREATER THAN 8' DEPTH BE ATTACHED TO PIPE TRACER WARE SHALL BE ATTACHED TO PIPE AND PLACED AT A DEPTH OF 4 TO 5 FEET DIRECTLY ABOVE SEWER PIPE WRAP TRACER WIRE AROUND OUTSIDE OF MANHOLE AND CONNECT EACH WIRE TO GROUND ROD - - (SEE CLTWATER STD. DETAIL) - - - - - - - - - SEWER TRUNK-"', LINE r, O R ANO. 12 GAUGE SOLID COPPER TRACER WIRE (TYP.) VALVE BOX ASSEMBLY (SEE CLTWATER STD. DETAIL) CONCRETE PAD (SEE CLTWATER STD. DETAIL) SEWER TRUNK N0. 12 GAUGE SOLID COPPER LINE TRACER WIRE (TYP.)1 STREET / ROADWAY CURB -- - - - - -- PLANTING STRIP SIDEWALK UFRIGHT-OF-WAY / N0. 12 GAUGE SOLID COPPER EASEMENT LINE A TRACER WIRE (TYP.) �/- WRAP TRACER WIRE AROUND OUTSIDE OF MANHOLE AND CONNECT EACH WIRE TO GROUND ROD (SEE CLTWATER STD. DETAIL) NO. 12 rTRACER WIREE(�) COPPER SEWER OUTFALL-/ SEWER MANHOLE -/\-SEWER OUTFALL �- NO SPLICE STREAM �... --- --------- �...- STREAM TRENCH DETAIL PROFILE VIEW TRACER WARE SHALL BE CLASS B CONCRETE SPECIFICATIONS STREET / ROADWAY STREET VIEW - GRAVITY SEWER TRACER WIRE - - - - CURB - - - - - PLACED IN CONDUIT WHEN SEWER SERVICE - LATERAL - 5.5 - - - - - - - - - - - - - - - - PLAN VIEW 14' TO 5' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PLANTING STRIP SLUMP RANGE -_-_-_-_-_-_-_-_-_-_--- - - - - - - - - - - - CURB - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - CURB - - - - - - - - - - NEW SERVICE ON EXISTING MAIN SIDEWALK WRAP TRACER WIRE AROUND OUTSIDE OF MANHOLE AND CONNECT LATERAL NO. 12 GAUGE SOLID NO. 12 GAUGE SOLID COPPER TRACER MAGNESIUM ANODE (1 LB. MIN.) EACH HARE TO GROUND ROD TRACER WIRE (TYP.) COPPER TRACER ____T_ ­ SEWER REQUIRED WHERE NO TRACER VALVE BOX CLEANOUT (SEE CLTWATER STD. DETAIL) CONCRETE PAD WARE (TYP.) (SEE CLTWATER STD. DETAIL) MANHOLE WIRE IS LOCATED ON SEWER MAIN CONCRETE PAD (SEE CLTWATER STD. DETAIL) PROPERTY / EASEMENT LINE EASEMENT LINE 12" T (�•) LOW F~ 4 mmmp FLOW JJ ?? EXIST. SEWER MAIN LINE WTHOUT TRACER WIRE SEWER MANHOLE NO SPLICE SEWER MAIN LINE SPLICE NO SPLICE SEWER MAIN UNE NOTES: 1. TRACER WIRE SHOWN AWAY FROM PIPE FOR CLARITY. TRACER WIRE SHALL BE INSTALLED IMMEDIATELY ADJACENT TO THE SEWER PIPE. TRACER WIRE SHALL BE FASTENED TO THE PIPE WITH ZIP TIES AT 10 FOOT INTERVALS. 2. TRACER WIRE SHALL BE SOLID COPPER NO. 12 GAUGE WITH 30 MILS GREEN HDPE INSULATION. FLOW TRACER WIRE FOR GRAVITY SEWER DEEPER THAN 8 ET SECTION VIEW SEWER SEWER MANHOLE FINISHED GRADE FINISHED GRADE f MANHOLE SPLICE CONDUIT GRAVITY SEWER MAIN PIPE - LESS THAN 8' DEPTH TRACING WIRE SHALL GRAVITY SEWER MAIN GREATER THAN 8' DEPTH BE ATTACHED TO PIPE TRACER WARE SHALL BE ATTACHED TO PIPE AND PLACED AT A DEPTH OF 4 TO 5 FEET DIRECTLY ABOVE SEWER PIPE WRAP TRACER WIRE AROUND OUTSIDE OF MANHOLE AND CONNECT EACH WIRE TO GROUND ROD - - (SEE CLTWATER STD. DETAIL) - - - - - - - - - SEWER TRUNK-"', LINE r, O R ANO. 12 GAUGE SOLID COPPER TRACER WIRE (TYP.) VALVE BOX ASSEMBLY (SEE CLTWATER STD. DETAIL) CONCRETE PAD (SEE CLTWATER STD. DETAIL) SEWER TRUNK N0. 12 GAUGE SOLID COPPER LINE TRACER WIRE (TYP.)1 STREET / ROADWAY CURB -- - - - - -- PLANTING STRIP SIDEWALK UFRIGHT-OF-WAY / N0. 12 GAUGE SOLID COPPER EASEMENT LINE A TRACER WIRE (TYP.) �/- WRAP TRACER WIRE AROUND OUTSIDE OF MANHOLE AND CONNECT EACH WIRE TO GROUND ROD (SEE CLTWATER STD. DETAIL) NO. 12 rTRACER WIREE(�) COPPER SEWER OUTFALL-/ SEWER MANHOLE -/\-SEWER OUTFALL �- NO SPLICE STREAM �... --- --------- �...- STREAM TRENCH DETAIL PROFILE VIEW TRACER WARE SHALL BE CLASS B CONCRETE SPECIFICATIONS STREET / ROADWAY `SEE MANHOLE y MINIMUM CEMENT CONTENT, SACKS PER CUBIC YARD WITH ROUNDED COURSE AGGREGATE - - - - CURB - - - - - PLACED IN CONDUIT WHEN SEWER SERVICE - LATERAL - 5.5 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 14' TO 5' - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - PLANTING STRIP SLUMP RANGE - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - SEWER SERVICESEWER MINIMUM STRENGTH - 28 DAY PSI 2,500 ===mmmmmmmmilommmmol ===OF=== SERVICE LATERAL SIDEWALK LATERAL NO. 12 GAUGE SOLID COPPER TRACER N0. 12 GAUGE SOLID COPPER WIRE (TYP.) TRACER WIRE (TYP.) RIGHT ____T_ ­ -OF -WAY /J CLEANOUT EASEMENT LINE VALVE BOX CLEANOUT CLEANOUT VALVE BOX ASSEMBLY CONCRETE PAD ASSEMBLY (SEE CLTWATER I (SEE CLTWATER STD. DETAIL) (SEE CLTWATER STD. DETAIL) STD. DETAIL) PROPERTY / CONCRETE PAD (SEE CLTWATER STD. DETAIL) PROPERTY / EASEMENT LINE EASEMENT LINE NOTES: 1. TRACER WIRE SHOWN AWAY FROM PIPE FOR CLARITY. TRACER WIRE SHALL BE INSTALLED IMMEDIATELY ADJACENT TO THE SEWER PIPE. TRACER WIRE SHALL BE FASTENED TO THE PIPE WITH ZIP TIES AT 10 FOOT INTERVALS. 2. TRACER WIRE SHALL BE SOLID COPPER NO. 12 GAUGE WITH 30 MILS GREEN HDPE INSULATION. FLOW TRACER WIRE FOR GRAVITY SEWER DEEPER THAN 8 ET SECTION VIEW SEWER SEWER MANHOLE FINISHED GRADE FINISHED GRADE f MANHOLE SPLICE CONDUIT GRAVITY SEWER MAIN PIPE - LESS THAN 8' DEPTH TRACING WIRE SHALL GRAVITY SEWER MAIN GREATER THAN 8' DEPTH BE ATTACHED TO PIPE TRACER WARE SHALL BE ATTACHED TO PIPE AND PLACED AT A DEPTH OF 4 TO 5 FEET DIRECTLY ABOVE SEWER PIPE WRAP TRACER WIRE AROUND OUTSIDE OF MANHOLE AND CONNECT EACH WIRE TO GROUND ROD - - (SEE CLTWATER STD. DETAIL) - - - - - - - - - SEWER TRUNK-"', LINE r, O R ANO. 12 GAUGE SOLID COPPER TRACER WIRE (TYP.) VALVE BOX ASSEMBLY (SEE CLTWATER STD. DETAIL) CONCRETE PAD (SEE CLTWATER STD. DETAIL) SEWER TRUNK N0. 12 GAUGE SOLID COPPER LINE TRACER WIRE (TYP.)1 STREET / ROADWAY CURB -- - - - - -- PLANTING STRIP SIDEWALK UFRIGHT-OF-WAY / N0. 12 GAUGE SOLID COPPER EASEMENT LINE A TRACER WIRE (TYP.) �/- WRAP TRACER WIRE AROUND OUTSIDE OF MANHOLE AND CONNECT EACH WIRE TO GROUND ROD (SEE CLTWATER STD. DETAIL) NO. 12 rTRACER WIREE(�) COPPER SEWER OUTFALL-/ SEWER MANHOLE -/\-SEWER OUTFALL �- NO SPLICE STREAM �... --- --------- �...- STREAM TRENCH DETAIL PROFILE VIEW TRACER WARE SHALL BE CLASS B CONCRETE SPECIFICATIONS `SEE MANHOLE y MINIMUM CEMENT CONTENT, SACKS PER CUBIC YARD WITH ROUNDED COURSE AGGREGATE 5.0 PLACED IN CONDUIT WHEN MINIMUM CEMENT CONTENT, SACKS PER CUBIC YARD WITH ANGULAR COURSE AGGREGATE 5.5 CONNECTION DETAIL MAXIMUM WATER -CEMENT RATIO GALLONS PER SACK 14' TO 5' NOT PLACED AT SEWER PIPE SLUMP RANGE 2" TO 4" WARNING TAPE- APE=== TRACER WIRE MINIMUM STRENGTH - 28 DAY PSI 2,500 ===mmmmmmmmilommmmol ===OF=== N0. 12 GAUGE SOLID WARNING TAPE COPPER TRACER WIRE(TYP.) N0. 12 GAUGE SOLID TRACER WIRE _Q COPPER TRACER SEWER WARE (TYP.) PIPE 12" T LATERAL FLOW TRENCH WIDTH 4" NATIVE TOPSOIL RESTORED TO ORIGINAL GRADE AND SEEDED WITH WETLAND SEED MIXTURE. IN UNDEVELOPED AREAS BACKFILL REMAINING PORTION OF TRENCH IN MAX 12" LIFTS TO 95% MAX DENSITY. BACKFILL TO 18" ABOVE PIPE FOR A LENGTH OF 12" WITH 18" MIN III CLASS B CONCRETE SPECIFIED r BELOW OR WITH WITH IMPERMEABLE CLAY HAVING A SPECIFIC DISCHARGE OF UNDISTURBED I I 1 1 X 10-5 CM/SEC OR LESS. CID .�. ANTI SEEP COLLAR SHALL EXTEND ..` A MIN. OF 18" ABOVE THE PIPE, 6" " INTO UNDISTURBED TRENCH WALLS 12 MIN I- 7-r---71 i--r-r=T -1 i _ I EACH SIDE AND 12" INTO UNDISTURBED =I I I=I I I=I I I=I I I=I =I I I=I I TRENCH BOTTOM. =1 1� BEDDING MATERIAL SHALL NOT BE INSTALLED WHERE ANTI -SEEP COLLAR IS LOCATED. NOTES: 1. EXISTING TOPSOIL SHALL BE REMOVED STOCKPILED AND PROTECTED FROM CONTAMINATION AND SHALL BE REPLACED AS TOPSOIL AFTER UTILITY INSTALLATION. 2. ANTI -SEEP COLLAR SHALL BE PLACED AT THE DOWNSTREAM WETLAND BOUNDARY AND A MIN. SPACING OF 150' UP THE GRADIENT UNTIL THE UTILITY EXITS THE WETLAND BOUNDARY UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 3. ANTI -SEEP COLLARS MAY BE CONSTRUCTED WITH COMPACTED CLAY, CLASS B CONCRETE, PVC OR METAL COLLARS. WETLAND CROSSINGS THAT ARE DIRECTIONALLY DRILLED AND PERPENDICULAR WETLAND CROSSINGS THAT ARE OPEN CUT AND LESS THAN 150' IN LENGTH DO NOT REQUIRE ANTI -SEEP COLLARS. 4. CONTRACTOR SHALL PROVIDE SUITABLE FORMING (TO BE REMOVED) TO CONTAIN CONCRETE FOR PROPER SHAPE AND DIMENSIONS. PROVIDE#4 BARS ® 12"OC EACH WAY. 5. ANTI -SEEP COLLAR MATERIAL AND INSTALLATION SHALL BE APPROVED BY THE ENGINEER PRIOR TO PLACING AND PRIOR TO BACKFILLING. 6. CONSTRUCTION AND SEEDING IN WETLAND AREAS SHALL BE IN ACCORDANCE WITH STATE AND FEDERAL REGULATIONS AND THE OWNER'S PERMIT REQUIREMENTS. SPECIAL CONDITIONS FOR WETLAND AREAS 1. THE CONSTRUCTION CORRIDOR IS LIMITED TO 40' IN WIDTH AND MUST BE MINIMIZED TO THE MAXIMUM EXTENT POSSIBLE 2. PRECONSTRUCTION CONTOURS TO BE RESTORED 3. STABILIZATION IS REQUIRED IMMEDIATELY ON COMPLETION OF EACH INDIVIDUAL CROSSING. 4. RESTORATION TO INCLUDE SEEDING WITH ANNUAL SPECIES FOR WET LOCATIONS (PERENNIALS SUCH AS FESCUE PROHIBITED). 5. THE TOP 6" TO 12" OF THE TRENCH SHOULD GENERALLY BE BACKFILLED WITH TOPSOIL FROM THE TRENCH 6. EXCESS MATERIAL SHALL BE REMOVED TO UPLAND AREAS UPON COMPLETION OF UTILITY LINE. ANTI -SEEP COLLAR DETAIL CHARLOTTE CHARLOTTE WATER W�TER CHARLOTTE, NORTH CAROLINA 7030700047-17-503 Job No. File No. Scales PLAN NTS PROFILE Hor. NTS Vert. NTS As Built Date A 2 16 TED FINAL DESIGN L. ASSOC JM No. Date By Revision Surveyed By Designed By STEVENS CREEK TRUNK SEWER PHASE I STANDARD SEWER DETAILS (SHEET 2 OF 2) Sheet Of TED MEB 5/4 18 121126 Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT CLASS B CONCRETE SPECIFICATIONS A) MINIMUM CEMENT CONTENT, SACKS PER CUBIC YARD WITH ROUNDED COURSE AGGREGATE 5.0 B) MINIMUM CEMENT CONTENT, SACKS PER CUBIC YARD WITH ANGULAR COURSE AGGREGATE 5.5 C) MAXIMUM WATER -CEMENT RATIO GALLONS PER SACK 6.8 D) SLUMP RANGE 2" TO 4" E) MINIMUM STRENGTH - 28 DAY PSI 2,500 NOTES: 1. EXISTING TOPSOIL SHALL BE REMOVED STOCKPILED AND PROTECTED FROM CONTAMINATION AND SHALL BE REPLACED AS TOPSOIL AFTER UTILITY INSTALLATION. 2. ANTI -SEEP COLLAR SHALL BE PLACED AT THE DOWNSTREAM WETLAND BOUNDARY AND A MIN. SPACING OF 150' UP THE GRADIENT UNTIL THE UTILITY EXITS THE WETLAND BOUNDARY UNLESS INDICATED OTHERWISE ON THE DRAWINGS. 3. ANTI -SEEP COLLARS MAY BE CONSTRUCTED WITH COMPACTED CLAY, CLASS B CONCRETE, PVC OR METAL COLLARS. WETLAND CROSSINGS THAT ARE DIRECTIONALLY DRILLED AND PERPENDICULAR WETLAND CROSSINGS THAT ARE OPEN CUT AND LESS THAN 150' IN LENGTH DO NOT REQUIRE ANTI -SEEP COLLARS. 4. CONTRACTOR SHALL PROVIDE SUITABLE FORMING (TO BE REMOVED) TO CONTAIN CONCRETE FOR PROPER SHAPE AND DIMENSIONS. PROVIDE#4 BARS ® 12"OC EACH WAY. 5. ANTI -SEEP COLLAR MATERIAL AND INSTALLATION SHALL BE APPROVED BY THE ENGINEER PRIOR TO PLACING AND PRIOR TO BACKFILLING. 6. CONSTRUCTION AND SEEDING IN WETLAND AREAS SHALL BE IN ACCORDANCE WITH STATE AND FEDERAL REGULATIONS AND THE OWNER'S PERMIT REQUIREMENTS. SPECIAL CONDITIONS FOR WETLAND AREAS 1. THE CONSTRUCTION CORRIDOR IS LIMITED TO 40' IN WIDTH AND MUST BE MINIMIZED TO THE MAXIMUM EXTENT POSSIBLE 2. PRECONSTRUCTION CONTOURS TO BE RESTORED 3. STABILIZATION IS REQUIRED IMMEDIATELY ON COMPLETION OF EACH INDIVIDUAL CROSSING. 4. RESTORATION TO INCLUDE SEEDING WITH ANNUAL SPECIES FOR WET LOCATIONS (PERENNIALS SUCH AS FESCUE PROHIBITED). 5. THE TOP 6" TO 12" OF THE TRENCH SHOULD GENERALLY BE BACKFILLED WITH TOPSOIL FROM THE TRENCH 6. EXCESS MATERIAL SHALL BE REMOVED TO UPLAND AREAS UPON COMPLETION OF UTILITY LINE. ANTI -SEEP COLLAR DETAIL CHARLOTTE CHARLOTTE WATER W�TER CHARLOTTE, NORTH CAROLINA 7030700047-17-503 Job No. File No. Scales PLAN NTS PROFILE Hor. NTS Vert. NTS As Built Date A 2 16 TED FINAL DESIGN L. ASSOC JM No. Date By Revision Surveyed By Designed By STEVENS CREEK TRUNK SEWER PHASE I STANDARD SEWER DETAILS (SHEET 2 OF 2) Sheet Of TED MEB 5/4 18 121126 Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT THE FOLLOWING SCHEDULES SHALL BE USED FOR RESEEDING DISTURBED AREAL CONSTRUCTION SEQUENCE - OUTFALLS EROSION & SEDIMENT CONTROL 1—CED STEEP SLOPES OR POOR SOILS AND LOW MAINTENANCE ****** MIXTURE ********************* RATE (LB/ACRE)*************************************** TALL FESCUE 100 SERICEA LESPEDEZA 30 KOBE LESPEDEZA 10 SEEDING DATES FALL LATE WINTER BEST _ AUG. 25 — SEPT. 15 FEB. 15 — MAR. 21 POSSIBLE M AUG. 20 — OCT. 25 FEB. 1 — APR. 15 SEEDING NOTES 1. FALL IS THE BEST FOR TALL FESCUE AND LATE WINTER FOR LESPEDEZAS. OVERSEEDING OF KOBE LESPEDEZA OVER FALL SEEDED TALL FESCUE IS VERY EFFECTIVE. 2. AFTER AUG. 15, USE UNSCARIFIED SERICEA SEED. 3. WHERE A NEAT APPEARANCE IS SPECIFIED, OMIT SERICEA AND SUBSTITUTE BERMUDAGRASS AT 15 LB/ACRE. USE ONLY WHERE BERMUDAGRASS WILL NOT BECOME A PEST AND ONLY UPON THE APPROVAL OF THE DIRECTOR OF ENGINEERING. 4. BETWEEN MAY 1 AND AUG. 15 ADD 10 LB/ACRE GERMAN MILLET OR 15 LB/ACRE SUDANGRASS. PRIOR TO MAY 1 AND AFTER AUG. 15, ADD 40 LB/ACRE RYE GRAIN. FERTILIZER APPLY LIME AND FERTILIZER AS REQUIRED BY SOIL TESTING RESULTS OR APPLY 4,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER. NO FERTILIZER SHALL BE PLACED WITHIN TEN (10) FEET OF STREAMS. MULCH APPLY 4,000-5,000 LB/ACRE GRAIN STRAW, OR EQUIVALENT COVER OF SUITABLE MULCHING MATERIAL. TACK BY USING ASPHALT, ROVING OR NETTING. NETTING IS TO BE USED ON STEEP SLOPES AS DIRECTED BY THE CONSTRUCTION DRAWINGS. NOTE: LESSER AMOUNTS OF STRAW MAY BE USED WITH MECHANICAL SPREADERS. MAINTENANCE RESEED, FERTILIZE AND MULCH DAMAGED AREAS IMMEDIATELY. REFERTILIZE AT END OF WARRANTY PERIOD IF GROWTH IS NOT SATISFACTORY TO THE DIRECTOR OF ENGINEERING. 2—CED GENTLE SLOPES, AVERAGE/GOOD MOISTURE RETENTION AND LOW MAINTENANCE ****** MIXTURE ********************* RATE (LB/ACRE)***************************************** TALL FESCUE 80 SERICEA LESPEDEZA 20 KOBE LESPEDEZA 10 SEEDING DATES FALL LATE WINTER BEST _ AUG. 25 — SEPT. 15 FEB. 15 — MAR. 21 POSSIBLE M AUG. 20 — OCT. 25 FEB. 1 — APR. 15 SEEDING NOTES 1. FALL IS BEST FOR TALL FESCUE AND LATE WINTER FOR LESPEDEZAS. OVERSEEDING OF KOBE LESPEDEZA OVER FALL SEEDED TALL FESCUE IS VERY EFFECTIVE. 2. AFTER AUG. 15, USE UNSCARIFIED SERICEA SEED. 3. WHERE A NEAT APPEARANCE IS SPECIFIED, OMIT SERICEA AND INCREASE KOBE LESPEDEZA TO 40 LB/ACRE. 4. BETWEEN MAY 1 AND AUG. 15 ADD 10 LB/ACRE GERMAN MILLET OR 15 LB/ACRE SUDANGRASS. PRIOR TO MAY 1 OR AFTER AUG. 15, ADD 40 LB/ACRE RYE GRAIN. 5.IN WETLAND AREAS, RESEEDING/REPLANTING SHALL INCLUDE ENDEMIC PLANT SPECIES SUCH AS SMARTWEED, FALSE NETTLE, CATTAIL SEDGE, SEDGES AND OTHER PLANTINGS AS RECOMMENDED BY THE N.C. WILDLIFE RESOURCES COMMISSION AND THE N.C. DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES. PERENNIALS SUCH AS FESCUE ARE PROHIBITED. TOP 6" TO 12" OF TRENCH TO BE BACKFILLED W/ ORIGINAL TOPSOIL FROM TRENCH FERTILIZER APPLY LIME AND FERTILIZER AS REQUIRED BY SOIL TESTING RESULTS OR APPLY 4,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER. NO FERTILIZER SHALL BE PLACED WITHIN TEN (10) FEET OF STREAMS, MULCH APPLY 4,000 LB/ACRE GRAIN STRAW, OR EQUIVILENT COVER OF SUITABLE MULCHING MATERIAL. TACK BY USING ASPHALT, ROVING OR NETTING. NETTING IS TO BE USED ON STEEP SLOPES AS DIRECTED BY THE CONSTRUCTION DRAWINGS. NOTE: LESSER AMOUNTS OF STRAW MAY BE USED WITH MECHANICAL SPREADERS. MAINTENANCE RESEED, FERTILIZE AND MULCH DAMAGED AREAS IMMEDIATELY. REFERTILIZE AT END OF WARRANTY PERIOD IF GROWTH IS NOT SATISFACTORY TO THE DIRECTOR OF ENGINEERING. NPDES Stormwater Discharge Permit for Construction Activities (NCG01) NCDENR/Division of Energy, Mineral and Land Resources STABILIZATION TIMEFRAMES (Effective Aug. 3, 2011) SITE AREA DESCRIPTION STABILIZATION TIMEFRAME EXCEPTIONS 4, L; Perimeter dikes, swales, ditches, slopes 7 days None High Quality Water (HQW) Zones 7 days None Slopes steeper than 3:1 7 days If slopes are 10' or less in length and are not steeper than 2:1, 14 days are allowed. Slopes 3:1 or flatter 14 days 7 days for slopes greater than 50' in length. All other areas with slopes flatter than 4:1 14 days None, except for perimeters and HQW Zones. ENVIRONMENTAL PROTECTION SEDIMENTATION AND EROSION CONTROL ALL EXISTING SENSITIVE LAND FEATURES AND STRUCTURES SHALL BE PROTECTED FROM EROSION AND SEDIMENTATION. ITEMS TO BE PROTECTED SHALL INCLUDE, BUT ARE NOT LIMITED TO, ALL DOWNSTREAM PROPERTY, NATURAL WATERWAYS, STREAMS, WETLANDS, YARDS, LAKES AND PONDS, CATCH BASINS, DRAINAGE DITCHES, ROADS, GUTTERS, AND NATURAL AREAS. SOIL EROSION AND SEDIMENTATION CONTROL SHALL BE PROVIDED AND MAINTAINED BY THE CONTRACTOR, AT HIS EXPENSE, THROUGHOUT THE LIFE OF THE CONTRACT AND DURING THE CONTRACT WARRANTY PERIOD, FOR ALL AREAS THAT ARE GRADED OR DISTURBED AS A RESULT OF THE CONTRACTOR'S WORK ACTIVITY. CONTROL MEASURES SHALL CONSIST OF APPROVED PRACTICES FOUND IN THE EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL AND AS SHOWN ON THE CONSTRUCTION DRAWINGS AS APPROVED BY THE N.C. DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES AND INSTALLED AS SUCH. IN THE EVENT THAT LOCAL CONDITIONS CHANGE TO RENDER DESIGNED SEDIMENTATION AND EROSION CONTROL INEFFECTIVE, THE CONTRACTOR SHALL IMMEDIATELY NOTIFY THE NCDEQ INSPECTOR FOR A FIELD CHANGE DISPOSITION. AFTER DISTURBED AREAS ARE STABILIZED AND ALL TEMPORARY MEASURES REMOVED, THE SEDIMENT SHALL BE SPREAD IN A MANNER NOT TO ADVERSELY AFFECT PROTECTION PROCEDURES AND THEN THE AREA SHALL BE SEEDED AND MULCHED. OTHERWISE, SEDIMENT IS TO BE DISPOSED OF BY HAULING AND SPREADING AS DETAILED ON THE DIVISION OF LAND RESOURCES' APPROVED SEDIMENTATION AND EROSION CONTROL DRAWINGS. ALL AREAS SHOWN AS WETLANDS ON THE CONSTRUCTION DRAWINGS SHALL BE PROTECTED BY DIRECTIONS GIVEN ON THE PLANS AND ALL WORK WITHIN THESE AREAS SHALL BE IN ACCORDANCE WITH PROVISIONS AS SET FORTH IN THE ARMY CORPS OF ENGINEERS 404 PERMIT, THE N.C. DEPARTMENT OF ENVIRONMENTAL QUALITY AND NATURAL RESOURCES 401 PERMIT/CERTIFICATION, AND THE DIVISION OF ENERGY, MINERAL AND LAND RESOURCES LETTER OF APPROVAL. SEEDING, GROUND COVERS, AND MULCHING AREAS DAMAGED BY CONSTRUCTION WORK SHALL BE RESTORED TO A CONDITION APPROVED BY CHARLOTTE WATER BY WORKING, FERTILIZING, SEEDING, AND MULCHING. SEEDING SHALL BE DONE WITHIN FIFTEEN (15) DAYS AFTER THE INITIAL GROUND DISTURBANCE. THE BED SHALL BE PREPARED BY PULVERIZING THE SOIL TO A DEPTH OF THREE INCHES. TILLAGE SHALL CONTINUE UNTIL A WELL—PULVERIZED, FIRM, AND UNIFORM SITE IS PREPARED CONFORMING TO ADJACENT PROPERTY. THE SOIL MUST BE LOOSE ENOUGH FOR WATER INFILTRATION AND ROOT PENETRATION. GOOD DRAINAGE MUST BE PROVIDED AND VISIBLE PONDING WILL NOT BE ALLOWED. ALL STONES, ROCKS, STICKS, RUBBISH, AND OTHER OBJECTIONABLE MATERIAL SHALL BE REMOVED PRIOR TO FERTILIZATION. THE pH OF THE SOIL SHALL BE NON—TOXIC TO THE SEED MIXTURE. PLANT SMALL GRAINS NO DEEPER THAN 1 INCH AND GRASSES/LEGUMES NO DEEPER THAN 1/2 INCH. PLANTING IS TO BE UNIFORM. 1. OBTAIN GRADING/EROSION CONTROL PLAN APPROVAL FROM NCDEQ. 2. SET UP A ON—SITE PRECONSTRUCTION CONFERENCE WITH THE INSPECTOR FROM THE NCDEQ TO DISCUSS EROSION CONTROL MEASURES. 3. INSTALL SILT FENCE, INLET PROTECTION, SEDIMENT TRAPS, DIVERSION DITCHES, TREE PROTECTION, AND OTHER MEASURES AS SHOWN ON PLANS, CLEARING ONLY AS NECESSARY TO INSTALL THESE DEVICES. 4. CALL FOR ON—SITE INSPECTION BY NCDEQ INSPECTOR. 5. THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES. 6. FOR PHASED EROSION CONTROL PLANS, CONTRACTOR SHALL MEET WITH NCDENR INSPECTOR PRIOR TO COMMENCING WITH EACH PHASE OF EROSION CONTROL MEASURES. 7. STABILIZE SITE AS AREAS ARE BROUGHT TO FINISHED GRADE. 8. COORDINATE WITH NCDEQ INSPECTOR PRIOR TO REMOVAL OF EROSION CONTROL MEASURES. MEASURES WILL NOT BE REMOVED UNTIL AREAS ARE PERMANENTLY STABILIZED. 9. ALL EROSION CONTROL MEASURES SHALL BE CONSTRUCTED IN ACCORDANCE WITH THE N.C. EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL, AND DETAILS SHOWN IN THESE PLANS. 10. THE CONTRACTOR SHALL DILIGENTLY AND CONTINUOUSLY MAINTAIN ALL EROSION CONTROL DEVICES AND STRUCTURES TO MINIMIZE EROSION. THE CONTRACTOR SHALL MAINTAIN CLOSE CONTACT WITH THE NCDENR INSPECTOR SO THAT PERIODIC INSPECTIONS CAN BE PERFORMED AT APPROPRIATE STAGES OF CONSTRUCTION. A CITY OF CHARLOTTE DEPARTMENT S i r 1'1I1t^T WOVEN FILTER FABRIC 0 I N 6' MAX. GENERAL NOTES: 1. WOVEN FILTER FABRIC SHALL BE USED WHERE SILT FENCE IS TO REMAIN FOR A PERIOD OF MORE THAN 30 DAYS. 2. STEEL POSTS SHALL BE 5'-0" IN HEIGHT AND BE OF THE SELF -FASTENER ANGLE STEEL TYPE. 3. TURN SILT FENCE UP SLOPE ENDS. 4. ORANGE SAFETY FENCE IS REQUIRED AT BACK OF SILT FENCE WHEN GRADING IS ADJACENT TO SWIM BUFFERS, STREAMS OR WETLANDS (REFER TO SWIM BUFFER GUIDELINES). THE COLOR ORANGE IS RESERVED FOR VISUAL IDENTIFICATION OF ENVIRONMENTALLY SENSITIVE AREAS. 5. DRAINAGE AREA CANNOT BE GREATER THAN 1/4 ACRE PER 100 FT OF FENCE. 6. SLOPE LENGTHS CAN NOT EXCEED CRITERIA SHOWN IN TABLE 6.62A NORTH CAROLINA EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL. 7. DO NOT INSTALL SEDIMENT FENCE ACROSS STREAMS, DITCHES, WATERWAYS OR OTHER AREAS OF CONCENTRATED FLOW. #467 COARSE AGGREGATE 6" DEEP. EXTEND 25' EACH SIDE OF BANKS. 2 �1 STEEL POST FILTER FABRIC U_ m Q� FLOW N ico ANCHOR SKIRT; EXCAVATE TRENCH AND COMPACT STREA BACKFILL MAINTENANCE NOTES: 1. FILTER BARRIERS SHALL BE INSPECTED BY THE FINANCIALLY RESPONSIBLE PARTY OR HIS AGENT IMMEDIATELY AFTER EACH RAINFALL AND AT LEAST DAILY DURING PROLONGED RAINFALL. ANY REPAIRS NEEDED SHALL BE MADE IMMEDIATELY. 2. SHOULD THE FABRIC DECOMPOSE OR BECOME INEFFECTIVE PRIOR TO THE END OF THE EXPECTED USABLE LIFE AND THE BARRIER STILL IS NECESSARY, THE FABRIC SHALL BE REPLACED PROMPTLY. 3. SEDIMENT DEPOSITS SHOULD BE REMOVED WHEN DEPOSITS REACH APPROX. HALF THE HEIGHT OF THE BARRIER. ANY SEDIMENT DEPOSITS REMAINING IN PLACE AFTER THE SILT FENCE IS REMOVED SHALL BE DRESSED TO CONFORM TO THE EXISTING GRADE, PREPARED AND SEEDED. TEMPORARY SILT FENCE FILL WITH CMUD STANDARD RIP RAP ROCK 1 ft. min. �PE SIZED TO CARRY NORMAL FLOW WHEN FLOWING HALF FULL USE DUCTILE IRON CMP OR RCP ONLY. 6" #467 STONE I I NOTES: 1. CLASS OR MEDIAN SIZE OF RIPRAP AND LENGTH, WIDTH AND DEPTH OF APRON TO BE DESIGNED BY THE ENGINEER. 2. REFER TO THE CHARLOTTE MECKLENBURG STORM WATER DESIGN MANUAL FOR RIPRAP APRON DESIGN STANDARDS. 3. RIPRAP SHOULD EXTEND UP BOTH SIDES OF THE APRON AND AROUND THE END OF THE PIPE OR CULVERT AT THE DISCHARGE OUTLET AT A MAXIMUM SLOPE OF 2:1 AND A HEIGHT NOT LESS THAN TWO THIRDS THE PIPE DIAMETER OR CULVERT HEIGHT. 4. THERE SHALL BE NO OVERFLOW FROM THE END OF THE APRON TO THE SURFACE OF THE RECEIVING CHANNEL. THE AREA TO BE PAVED OR RIPRAPPED SHALL BE UNDERCUT SO THAT THE INVERT OF THE APRON SHALL BE AT THE SAME GRADE (FLUSH) WITH THE SURFACE OF THE RECEIVING CHANNEL. THE APRON SHALL HAVE A CUTOFF OR TOE WALL AT THE DOWNSTREAM END. 5. THE WIDTH OF THE END OF THE APRON SHALL BE EQUAL TO THE BOTTOM WIDTH OF THE RECEIVING CHANNEL. MAXIMUM TAPER TO RECEIVING CHANNEL 5:1 6. ALL SUBGRADE FOR STRUCTURE TO BE COMPACTED TO 95% OR GREATER. 7. THE PLACING OF FILL, EITHER LOOSE OR COMPACTED IN THE RECEIVING CHANNEL SHALL NOT BE ALLOWED. 8. NO BENDS OR CURVES IN THE HORIZONTAL ALIGNMENT OF THE APRON WILL BE PERMITTED. ""'^"' GRADE CROSSING LOCATIONS A16+25 A25+85 A29+75 A34+55 A45+05 A64+35 SURFACE FLOW DIVERSION //"-- SURFACE FLOW DIVERSION TEMPORARY STREAM CROSSING �o SURFACE FLOW 0 DIVERTED BY SWALE— IV NOTES: 1. REMOVE THE STRUCTURE WHEN NO LONGER NEEDED. (NOT TO EXCEED 1 YEAR). 2. AS A MINIMUM, DESIGN THE STRUCTURE TO PASS 2 YEAR PEAK FLOW WITHOUT OVERTOPPING. 3. ENSURE THAT DESIGN FLOW VELOCITY AT THE OUTLET OF THE CROSSING STRUCTURE IS NON-EROSIVE FOR THE RECEIVING STREAM CHANNEL. 4. ADDITIONAL MEASURES MAY BE REQUIRED BY THE EROSION CONTROL COORDINATOR OR CITY ENGINEER BASED ON SITE SPECIFIC CONDITIONS. 1/2 PIPE DIAMETER OR 12" WICHEVER IS GREATER RIP RAP F_ 1v 1�IZ_r_ rirF_ koF_F_ ivvIF_ �I PROVIDE PIPE SIZE, INVERTS, SLOPE AND MATERIAL FOR EACH CROSSING. SEED AND MULCH W/--1 / CROSSING LOCATIONS SURFACE BINDER AGGREGATE BED OVER A26+65 GEOTEXTILE FILTER CLOTH AGGREGATE APPROCH C1+70 1:5 (V: H) MAXIMUM SLOPE ON ROAD SURFACE FLOW DIVERTED BY SWALE SURFACE FLOW DIVERTED BY SWALE JNEW ROAD GEOTEXTILE FILTFER CL ORIGINAL STREAM BLD I I RIP RAP STD. DET. #29 I I W RIP RAP TEMPORARY FORD CROSSING H �I I� B B NOTES: 1. SLOPE APPROACHES TO CROSSING 2:1 OR FLATTER. 2. SPILLWAY LENGTH = BANK TO BANK WIDTH OF STREAM OR AS SHOWN ON PLANS. 3. PIPE TO EXTEND COMPLETELY ACROSS PERMANENT RIGHT OF WAY AND 1 ft BEYOND LIMITS OF RIP RAP. NOTE: MINIMUM H=2/3 PIPE DIAMETER PERMANENT STREAM CROSSING r, ,, vvl STONE LAYER OF FILTER FABRIC SECTION B -B (NOT TO SCALE) CHARLOTTE CHARLOTTE WATER W6TER CHARLOTTE, NORTH CAROLINA 7030700047-17-503 Job No. File No. Scales PLAN NTS PROFILE Hor. NTS Vert. NTS As Built Date STEVENS CREEK TRUNK SEWER PHASE I EROSION CONTROL DETAILS (SHEET 1 OF 3) A 2/161 TED I FINAL DESIGNSheet Of L. ASSOC JEM TED MEB 5/4/18 23 26 No. Date By Revision Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT A L = THE DISTANCE SUCH THAT POINTS A AND B ARE OF EQUAL ELEVATION 9" MIN. 1.5' MIN.1 A L B 6' TYP. FILL SLOPE NOTES: SPACE CHECK DAM IN A CHANNEL SO THAT THE CREST FILTER FABRIC OF DOWNSTREAM DAM IS AT ELEVATION OF THE TOE OF UPSTREAM DAM A 2' MI 2' MIN COMPACTED BERM CHECK DAM SPACING FINIS NATURq� SILT FENCE ) (SEE NOTE 2 GROUND CLASS B RIPRAP iygT CONSTRUCTION SPECIFICATIONS: 12" OF NCDOT #5 OR #57 1. PLACE STONE TO THE LINES AND DIMENSIONS SHOWN IN THE PLAN ON A WIDTH AND DEPTH U�4 G ROUND WASHED STONE FILTER FABRIC FOUNDATION. OF DITCH TO BE DESIGNED 2. KEEP THE CENTER STONE SECTION AT LEAST 9 INCHES BELOW NATURAL 2'7 BY ENGINEER (18" MIN) GROUND LEVEL WHERE THE DAM ABUTS THE CHANNEL BANKS. 24" MAX. 3. EXTEND STONE AT LEAST 1.5 FEET BEYOND THE DITCH BANK TO KEEP WATER AT CENTER FROM CUTTING AROUND THE ENDS OF THE CHECK DAM. 4. SET SPACING BETWEEN DAMS TO ASSURE THAT THE ELEVATION AT THE TOP FILTER CLOTH NOTE: OF THE LOWER DAM IS THE SAME AS THE TOE ELEVATION OF THE UPPER DAM. 5. PROTECT THE CHANNEL AFTER THE LOWEST CHECK DAM FROM HEAVY FLOW 1. DITCH SHOULD HAVE LONGITUDINAL SLOPE OF 1%. THAT COULD CAUSE EROSION. 4' TO 6' - 6. MAKE SURE THAT THE CHANNEL REACH ABOVE THE MOST UPSTREAM DAM 2. SILT FENCE MAY BE REQUIRED BEHIND BERM IS STABLE. SECTION VIEW A—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w z ~ w � N 00 U J m D a CHARLOTTE CHARLOTTE WATER W6TER CHARLOTTE, NORTH CAROLINA 7030700-503 STEVENS CREEK Jobb No. No. File No. Scales TRUNK SEWER PHASE I PLAN NTS STABILIZED CONSTRUCTION ENTRANCE PROFILE Hor. NTS EROSION CONTROL DETAILS Vert. NTS (SHEET 2 OF 3) As Built Date Of A 2/16 TED FINAL DESIGNSheet L. ASSOC JEM TED MEB 5/4/18 24 26 No. Date By Revision Surveyed By Designed By Drawn By Project—Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT TEMP. STONE DITCH CHECK SN�p. NOTES: P PMEN� USE CLASS 'B' EROSION CONTROL STONE FOR STRUCTURAL STONE. THE ENGINEER MAY DIRECT THE OPTION OF CLASS "A" STONE FOR SITES HAVING LESS THAN 4' MAX. 8' MAX. PLACE POST AT LOW POINTS ONE (1) ACRE DRAINAGE AREA AND A DITCH EDGE OF STRUCTURAL STONE PAVEMENT GRADE LESS THAN 3%. 5' MIN. 18" � G1• USE NO. 5 OR NO. 57 STONE FOR SEDIMENT 1' i N. 1 �3: SEDIMENT ��� OQ�' CONTROL. PLACE SEDIMENT CONTROL STONE 5 CONTROL STONE 5� AS DIRECTED BY THE ENGINEER. 5 MIN.�,OQ� ?'1 5' MAX. 2' STRUCTURAL STONE ELEVATION COARSE AGGREGATE 1 S S�Op Z• F BACK SLOPE 2-3" v� 3 8' n� LINE OF POST Mqk 18" z pW O 0 12" ISOMETRIC VIEW BEYOND ,1 II SUPPORT WIRE FILTER FABRIC PROFILE SECTION 1' MIN.NATURAL GROUND /r POST 18" SLOPE_ POST MN6�1 9 TYPICAL COMPACTED 14LASS A STONE STRUCTURAL STONE OVERFILL 6" DESIGN FOR SETTLEMENT MD TEMPORARY GRAVEL DIVERSION DITCH FOR VEHICLE CROSSING SETTLED TOP 2 MIN. dt- 2•� II MIN. MIN. T., CROSS SECTION If 5' MAX. FILL EMERGENCY VEE DITCH BY—PASS 6" 4" BELOW SETTLED WEIR LENGTH TOP OF DAM SECTION A — A PLUS 5 FEETNATURAL NATURAL GROUND GROUND 1' MIN. FOR POOR DEFINED CHANNELS CROSS SECTION A� ' MIN NOTES: COMPACTED SOIL I 2' MINS{ USE CLASS 'B' EROSION CONTROL STONE FOR STRUCTURAL STONE. CROSS SECTION TRAPEZOIDAL DITCH USE NO. 5 OR NO. 57 STONE FOR SEDIMENT CONTROL. MPX DIKE MAY EXTEND ALONG MORE THAN ONE SIDE OF THE TRAP AREA. PROVIDE A 2. 7 2:1 TOTAL SEDIMENT STORAGE VOLUME OF 1800± CUBIC FEET PER ACRE OF DISTURBED 'yq,� 18" MIN FLOW AREA. SOME OF THE REQUIRED VOLUME MAY BE PROVIDED BY OTHER UP OR BASE OF DITCH �� DOWNSTREAM CONTROLS. 4' MAX. AN UNDERLAY OF STRUCTURAL STONE WITH FILTER FABRIC MAY BE REQUIRED BY 12" 12" MIN. i THE ENGINEER. SEDIMENT IFTRAP A 6' TYPICAL FLOW PLAN DRAINAGE AREA WEIR LENGTH (ACRES) (FT) 6.0 -� I' 4-6" REINFORCED STABILIZATION OUTLET TEMPORARY EARTHEN DIVERSION DITCH 3 TYPE ------- 4 10.0 SILT BASIN 12" THICK SEDIMENT 5 12.0 CONTROL STONE ELEVATION VIEW TEMPORARY ROCK SEDIMENT DAM TYPE 'B' TEMPORARY ROCK SILT CHECK TYP 'B' 3'-0" BACKFILL TOP OF BANK SECTION TOP OF DITCH SLOPE 4 FT OF MATTING WITH MIN 6" TOPSOIL TOP OF BANK EXPOSE NO MORE THAN 12 IN 2 IN OF STAKE (TYP.) 30 IN BASE OF DITCH FORPLANTS —V— DITCH > 7 STAKE ALONG TOE OF HERBACEOUS (SWITCH GRASS) SEED AND MULCH WITH z SLOPE AT 1 FT SPACINGS COIR NET OVERLAY SECURE EROSION CONTROL MATTING ROLANKA BioD—MAT 70 OR APPROVED EQUAL N WITH 2 IN X 2 IN X 30 IN NOTCHED WOOD DEAD STAKES INSTALL ANCHORS IN ACCORDANCE WITH MANUFACTURES SPECIFICATIONS BASE OF DITCH EROSION CONTROL MATTING FOR FLAT TOE OF SLOPE SCOUR LINE 1• BOTTOM DITCH �Q�G TOP OF DITCH SLOPE STONE RIP—RAP O PLAN KEY IN EROSION CONTROL MATTING FILTER FABRIC, MIRAFI 160N OR EQUAL TOP OF DITCH SLOPE FOR A DEPTH OF 1 FT PER MANUFACTURER'S RECOMMENDATIONS O NOTES: NOTES: 24" MIN a + ,�1• 1. DETAIL #2 IS FOR MINOR STREAMS OR DRAINAGE FEATURES OUTSIDE MECKLENBURG COUNTY S.W.I.M. 1. BEGIN AT TOP OF SLOPE AND ANCHOR FIBER MATTING IN A 12 IN DEEP INITIAL ANCHOR BUFFERS. OTHERWISE NOTED ON PLANS. LENGTH IN FEET EQUALS TWCE THE NADTH TRENCH. BACKFILL TRENCH AND TAMP EARTH FIRMLY. Q 2. DETAIL SHALL ONLY BE USED UNDER REQUEST AND BASE OF DITCH FLOW LINE MINIMUM BASE OF DITCH FLOW LINE 2. UNROLL FIBER MATTING DOWNSLOPE IN THE DIRECTION OF WATER FLOW. tij DIRECTION OF OWNER/ENGINEER. 3. OVERLAP EDGES OF ADJACENT PARALLEL ROLLS BY 6 IN AND ANCHOR AT 12 IN CENTERS. 0z 4. WHEN FIBER MAT MUST BE SPLICED, PLACE END OVER END (SHINGLE STYLE) WITH 12 IN N OVERLAP AND ANCHOR USING TWO STAGGERED ROWS OF STAKES AT 6 IN CENTERS. CREEK BED 5. LAY FIBER MAT LOOSELY AND ANCHOR SUFFICIENTLY TO MAINTAIN DIRECT CONTACT CLASS 1 RIPRAP MINIMUM OF 24" THICKNESS WITH THE SOIL — DO NOT STRETCH. FOR STONE SIZE SEE SPECIFICATIONS. 6. FOR SLOPES 2:1 AND STEEPER USE A MINIMUM OF 3 STAKES PER SQUARE YARD AND FOR SLOPES FLATTER THAN 2:1 USE A MINIMUM OF 2 STAKES PER SQUARE YARD. 7. ANCHOR, FILL, AND COMPACT END OF FIBER MATTING IN 12 IN X 6 IN TERMINAL R L O T T E CHARLOTTE WATER ANCHOR TRENCH (MIRROR IMAGE OF INITIAL TRENCH). /CHARLOTTE �H�A �/ �/ 6T E R CHARLOTTE, NORTH CAROLINA ELEVATION STREAMBANK STABILIZATION DETAIL J2 SILT BASIN TYPE 'B' EROSION CONTROL MATTING DETAIL 7030Job 4No. -503 File No. STEVENS CREEK Scales TRUNK SEWER PHASE I PLAN NTS PROFILE Hor. NTS EROSION CONTROL DETAILS Vert. NTS (SHEET 3 OF 3) As Built Date Of A 2/16 TED FINAL DESIGNSheet L. ASSOC JEM TED MEB 5/4/18 25 26 No. Date By Revision Surveyed By Designed By Drawn By Project—Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT A CITY OF CHARLOTTE DEPARTMENT 8- 5/8- LAG BOLTS / 9. 1 0 l -- 8" x 8" TREATED x 8' PRESSURE POST INSTALLED14'- 5 PANEL STEEL FARM 28" LONG 5/16" _ 9" i -- 3' IN GROUND (TYP.) GATE, W/ 2" TUBING, 16GA, LINK CHAIN ;� 150" 5" SEE FENCE DETAILS 9" - - �5"� X X X X j X X X X 5" SQUARE POST VARIES EXISTING NATURAL GRADE i a C-4 1.9" 3.7" 10'-12' 4 -RAIL PVC FENCE .�" .085" 1.5" �5.5" #57 STONE (TYP.) E0- c 1 1/2" x 5 1/2" RAIL 0 0 0 � 1 1 / NOTES: 1. NO PADLOCK REQUIRED. GATE SHALL BE PROVIDED WITH CHAIN 0 / LATCH. o \ 2. ALL HARDWARE SHALL BE GALVANIZED STEEL. ° OUTSIDE CAP 5/8" LAG o BOLTS FARM GATE DETAIL EXISTING NATURAL GRADE 10'-12' 4 -RAIL PVC GATE DOME CORNER TOP RAIL BRACE RAIL CHAIN UNK FABRIC LINE POST (3) STRANDS OF BARBED WIRE NOTES: CHAINLINK FENCE DETAIL SHALL BE USED FOR ANY REMOVAL AND REPLACEMENT REQUIRED AT PACKAGE WASTEWATER TREATMENT PLANT CORNER TOP ARM POST 1.66" (42.2MM)(1 �") 1.66" (42.2MM) MESH GA 45' B/W ARM EA CONSISTING OF 2 STRAND PER SPECIFICATIONS UNE WIRE W/ 4 BARBS TO FACILITATE CONSTRUCTION. EXISTING FENCE MAY BE REQUIRED AND (OPTIONAL) (1) OD ANY REPLACEMENT PARTS NEEDED SHALL BE INCORPORATED AS FOLLOWS: END POST 1. FENCE FABRIC: WARE SHALL BE ZINC COATED, GALVANIZED AFTER iso WEAVING (GAW) 1.2 OZ SQ. FT. CLASS(, HELICALLY WOUND AND � WOVEN 6' FABRIC WITH 2" DIAMOND MESH, 9 GAUGE W/ CORE LENGTH VARIES (15' MAX.) DIAMETER OF 0.148" AND BREAK LOAD OF 1290 LBF. SELVAGE OF FABRIC SHALL BE TWISTED AT TOP AND KNUCKLED AT BOTTOM. 14 GUAGE WIRE TENSION BAND JIRAIL = 2. STEEL FENCE FRAME MEMBERS: STEEL PIPE - TYPE 1, SCHEDULE 12 O.C. 305MM TIE TENSION 40, HOT DIPPED GALVANIZED WITH MINIMUM AVERAGE 1.8 OZ/ SQ. BAR _ FT. OF COATED SURFACE AREA. END, GATE, AND CORNER POST i z z 2.875" OD, 5.79 LBS/FT. UNE POST 2.375" OD, 3.65 LBS/FT. TOP 4'-O" 6'-O" F BRACE BAND UNE m B RAIL AND BRACES 1.660" OD, 2.27 LBS/FT. a ll HOG POST TIE 12" as � V) � RING a 3. SWING PERSONNEL GATES: GALVANIZED FRAMEWORK; WELDED m 18" OC z w 1-5/8" OD GATE FRAME, WEIGHT - 2.27 LB/FT, 6' FABRIC, GAUGE v 9, 2" DIAMOND MESH; 3" OD GATE POSTS, WEIGHT - 5.79 LBS/FT. USE OF CORNER FITTINGS IS NOT PERMITTED. ADJUSTABLE TRUSS ROD TENSION WIRE s I" (9.5MM) DIA. a 7 GAUGE ° BOTTOM SELVAGE 4. DOUBLE PANEL SWING GATE: GALVANIZED FRAMEWORK; WELDED 2" KNUCKLED OD PIPE, WEIGHT - 2.27 LB/FT; 6' FABRIC, GAUGE 9, 2" MESH; TRUSS ROD TRUSS ROD 4" OD GATE POSTS, WEIGHT 9.10 LBS/FT. USE OF CORNER STEEL STUDDED T POST i ADJUSTING UNIT -T U. ADJUSTING UNIT FITTINGS IS NOT PERMITTED. (3 -STRAND) - 1.33LB/FT 20_0» (TYP) J� 5. ALL GATES SHALL HAVE DIAGONAL BRACING USING 3/8" 10'-0" O.C. MAXIMUM ADJUSTABLE TRUSS RODS. FENCE POST TO BE EQUALLY SPACED FOOTINGS: DIA. (4X) POST DIA, MIN 3'-0 (914MM) TI TYPICAL FENCE SECTION 6. FITTINGS: MEET ASTM F 626, ALL GLAVANIZED, 6" TOP RAIL SLEEVES, 7 GA GALVINIZED STEEL TENSION WIRE, ALL NUTS AND BOLTS SHALL BE GALVINIZED, TENSION BARS 3/16" x 3/4'. BARBED WIRE; GLAVANIZED COATED ASTM A-121 TYPE Z - CLASS 3 WITH 0.80 OZ/SF ZINC COATED WIRE - DESIGN #12- 4-5-14R, DOBLE STRAND, 12-1/2 GAUGE, TWISTED LINE WIRE WITH, 4 POINT BARBS, SPACED 5" OC W/ 3 STRANDS. PRESSED STEEL ARMS BARBED WIRE SUPPORT ARMS W/ 3 ATTACHMENT ROWS. 7. VERTICAL AND HORIZONTAL MEMBERS MAXIMUM 8' O.C. OPENING OPENING (FACE TO FACE) (FACE TO FACE) WIGGINS PROPERTY FENCE REPLACEMENT 3 STRAND DOME CAP 3 STRAND BARBED WIRE WHERE REQ'D TERMINAL/ BARBED WIRE TERMINAL/ WHERE REQ'D GATE POST GATE POST TOP RAIL TOP RAIL NoCHAIN LINK FABRIC TENSCHAIN (BANDS �v MESH GA LINK FABRIC MESH GA AR AT 12" INTERVALS PER SPECIFICATIONS CHARLOTTE PER SPECIFICATIONS BAR BANDS BRACE RAIL C H A RL O TT E W AT E R BRACE RAIL W6T E R 1-7/8" 0 D (48.3MM) FRAME 3/8 -TRUSS ROD LATCH CHARLOTTE, NORTH CAROLINA LATCH TENSION BAR x TENSION BAND TENSION BAR DROP 1-7/8" O.D. 7030700047-17-503 HINGE 3/8" TRUSS ROD ROD (48.3MM) FRAME Job No. File No. STEVENS CREEK BOTTOM TENSION WARE HINGE TRUSS RO BOTTOM TENSION WIRE Scales TRUSS ROD ADJUSTING TRUNK SEWER PHASE I ADJUSTING UNIT UNIT PLAN NTS FOOTINGS: DIA. (4X) PROFILE Hor. NTS POST DIA. MIN. tO FENCE DETAILS -FOOTINGS: DIA. (4X) I ° 3'-0" (914MM) Vert. NTS POST DIA. MIN. �t 3'-0" (914MM) As Built Date GATE PLAN TYPICAL DOUBLE SWING GATE A 2/16 TED FINAL DESIGNSheet L. ASSOC JEM Of TED MEB 5/4/18 26 26 No. Date By Revision Surveyed By Designed By Drawn By Project-Engr Approved By Date A CITY OF CHARLOTTE DEPARTMENT i r` � • .�� � s r � rl` Il y � � • t , ' � i Iy '� r - �.� riga f r— ���,�'i � ��P k �\- - fi', /G4 ,�, ,� I � e �. t�J• � 1p- - III - 3 o17) lana I. iso s L r 1 ✓. .V ��y,/ Vii,' ' - - / 9 588 '" 11 all \` _ � t.• - ��O �_ - � �I} -, .-_ � /� 3s87uoa^.N. 3 x•530 40' 531 1532 IN RIDR�EOi SLRVEv, RESTDN, VIRGINIA—,996 - 35°07'30" 53346 E 130°37'30" ROAD CLASSIFICATION I, I MILE Primary highway, Light-duty road, hard or ou UM 7000 FEET hard surface improved surface I KILOMETER Secondary highway, hard surface _ Unimproved road 329 J Interstate Route 00. S. Route (, State Route �P QUADRANGLE LOCATION FKAPP HIST RICA fS MIM HILL, NC�STANDARDS Revisions shown in purple compiled in Cooperation with35080-85-TF-024/EY North Carolina Department of Environment, Health and 10 �p INIA 22092 Natural Resources from imagery dated 1993 and other sourc 1993 m =r- AVAILABLE ON REQUEST Map edited 1996 REC T FILE COPY OMA 4854 II NW-SERIES V842 Information shown in purple may not meet I Content standards and may conflict with previously mapped contours 35° 9'19" N g r _g 35° 8'0!'N 530200 530600 531000 531400 531800 532200 3 0 Map Scale: 1:17,100 if printed on A landscape (11"x8.5") sheet Meters N 0 250 500 1000 1500 Feet 0 500 1000 2000 3000 Map projection: Web Mercator Comer coordinates: WGS84 Edge tics: UTM Zone 17N WGS84 G}DA Natural Resources Web Soil Survey Conservation Service National Cooperative Soil Survey Soil Map—Mecklenburg County, North Carolina, and Union County, North Carolina 3: o - o a M m ro 530200 530600 531000 531400 531800 532200 532600 539000 533400 533800 35° 9' 19" N g 35° 8'0" N 533800 3 lV V M 12/4/2017 Page 1 of 4 Soil Map—Mecklenburg County, North Carolina, and Union County, North Carolina MAP LEGEND Area of Interest (AOI) Area of Interest (AOI) Soils The soil surveys that comprise your AOI were mapped at Soil Map Unit Polygons im 0 Soil Map Unit Lines 0 Soil Map Unit Points Special Point Features Vo Blowout 4�, Other Borrow Pit Clay Spot •� Special Line Features Closed Depression Gravel Pit Water Features Gravelly Spot Streams and Canals Landfill Lava Flow Transportation Marsh or swamp + Mine or Quarry Miscellaneous Water Interstate Highways Perennial Water US Routes Rock Outcrop Major Roads Saline Spot 4 Sandy Spot Severely Eroded Spot Background Sinkhole ® Aerial Photography Slide or Slip oa Sodic Spot MAP INFORMATION Spoil Area The soil surveys that comprise your AOI were mapped at 1:24,000. Stony Spot Please rely on the bar scale on each map sheet for map Very Stony Spot measurements. Wet Spot Source of Map: Natural Resources Conservation Service 4�, Other Web Soil Survey URL: Coordinate System: Web Mercator (EPSG:3857) •� Special Line Features Maps from the Web Soil Survey are based on the Web Mercator Water Features projection, which preserves direction and shape but distorts Streams and Canals distance and area. A projection that preserves area, such as the Albers equal-area conic projection, should be used if more Transportation accurate calculations of distance or area are required. Rails This product is generated from the USDA-NRCS certified data as Interstate Highways of the version date(s) listed below. US Routes Soil Survey Area: Mecklenburg County, North Carolina Major Roads Survey Area Data: Version 16, Sep 26, 2017 Local Roads Soil Survey Area: Union County, North Carolina Survey Area Data: Version 17, Oct 3, 2017 Background ® Aerial Photography Your area of interest (AOI) includes more than one soil survey area. These survey areas may have been mapped at different scales, with a different land use in mind, at different times, or at different levels of detail. This may result in map unit symbols, soil properties, and interpretations that do not completely agree across soil survey area boundaries. Soil map units are labeled (as space allows) for map scales 1:50,000 or larger. Date(s) aerial images were photographed: Jun 14, 2015—Feb 8, 2017 The orthophoto or other base map on which the soil lines were compiled and digitized probably differs from the background imagery displayed on these maps. As a result, some minor shifting of map unit boundaries may be evident. UUP Natural Resources Web Soil Survey 12/4/2017 10111111 Conservation Service National Cooperative Soil Survey Page 2 of 4 Soil Map -Mecklenburg County, North Carolina, and Union County, North Carolina Map Unit Legend USDA Natural Resources Web Soil Survey 12/4/2017 Conservation Service National Cooperative Soil Survey Page 3 of 4 Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI CeB2 Cecil sandy clay loam, 2 to 8 865.4 59.2% percent slopes, moderately eroded CeD2 7.5% Cecil sandy clay loam, 8 to 15 109.0 percent slopes, moderately eroded 16.8 1.1% GeB2 Georgeville silty clay loam, 2 to 103.3 7.1% 8 percent slopes, moderately flooded eroded GeD2 Georgeville silty clay loam, 8 to 17.6 1.2% 15 percent slopes, moderately eroded GoD Goldston very channery silt 7.7 0.5% loam, 8 to 15 percent slopes HeB Helena sandy loam, 2 to 8 45.1 3.1% percent slopes LgB Lignum gravelly silt loam, 2 to 40.5 2.8% 8 percent slopes MeB Mecklenburg fine sandy loam, 3.8 0.3% 2 to 8 percent slopes MeD Mecklenburg fine sandy loam, 6.9 0.5% 8 to 15 percent slopes MO Monacan loam, 0 to 2 percent 152.1 10.4% slopes, frequently flooded PaE Pacolet sandy loam, 15 to 25 4.5 0.3% percent slopes VaB Vance sandy loam, 2 to 8 19.1 1.3% percent slopes VaD Vance sandy loam, 8 to 15 3.8 0.3% percent slopes W Water 1.2 0.1% Subtotals for Soil Survey Area 1,380.0 94.3% Totals for Area of Interest 1,462.9 100.0% USDA Natural Resources Web Soil Survey 12/4/2017 Conservation Service National Cooperative Soil Survey Page 3 of 4 Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI BdB2 Badin channery silty clay loam, 5.7 0.4% 2 to 8 percent slopes, moderately eroded BdC2 Badin channery silty clay loam, 8.4 0.6% 8 to 15 percent slopes, moderately eroded 16.8 1.1% ChA Chewacla silt loam, 0 to 2 percent slopes, frequently flooded USDA Natural Resources Web Soil Survey 12/4/2017 Conservation Service National Cooperative Soil Survey Page 3 of 4 Soil Map—Mecklenburg County, North Carolina, and Union County, North Carolina USDA Natural Resources Web Soil Survey 12/4/2017 Conservation Service National Cooperative Soil Survey Page 4 of 4 Map Unit Symbol Map Unit Name so Acres in AOI Percent of AOI GfB2 Georgeville silty clay loam, 2 to 24.3 1.7% 8 percent slopes, moderately eroded GoC Goldston very channery silt 4.6 0.3% loam, 4 to 15 percent slopes ScA Secrest-Cid complex, 0 to 3 1.9 0.1% percent slopes TaB Tarrus gravelly silt loam, 2 to 8 10.6 0.7% percent slopes TaC Tarrus gravelly silt loam, 8 to 4.8 0.3% 15 percent slopes TbB2 Tarrus gravelly silty clay loam, 5.8 0.4% 2 to 8 percent slopes, moderately eroded Subtotals for Soil Survey Area 82.9 5.7% Totals for Area of Interest 1,462.9 100.0% USDA Natural Resources Web Soil Survey 12/4/2017 Conservation Service National Cooperative Soil Survey Page 4 of 4 Mitigation Plan Additional Responses to Variance Application Section C. Proposed Impacts and Mitigation. 3. Provide a description of how mitigation will be achieved at your site pursuant to the mitigation requirements of the applicable river basin/watershed. As previously mentioned in the project description, Stevens Creek Trunk Sewer is being constructed in conjunction with the Stevens Creek Stream Restoration project (7,267 LF along Stevens Creek and 3,328 LF along Stevens Creek Tributary) under one contract. Charlotte Water and Mecklenburg County Storm Water have been working together to complete these projects on the same timeline. In doing this, we have been able to reduce overall clearing limits by utilizing each project's clearing area for construction. The sewer benefits from using temporary areas for construction, and the stream benefits from utilizing the sewer alignment for access which amounts to a reduction in total area needed to construct the sewer. A much greater amount of upland clearing would have been required had the sewer project been constructed outside of the stream restoration project limits. Without the stream restoration project, all temporary construction easements for the sewer project would have been placed upland versus utilizing the overlapping area which is provided from the stream restoration project. Construction will be performed utilizing Best Management Practices (BMPs) to reduce impacts by maintaining NCDEQ approved erosion control devices. The trunk sewer project will serve many needs one of which will provide sewer to the Stevens Creek Nature Preserve's nature center. In addition, this project will take an existing package wastewater treatment plant (PWWTP) offline and will convey wastewater to the McAlpine Creek WWTP. The Oxford Glen PWWTP is currently permitted for 0.075 MGD with average flows of 0.024 MGD (2016 flow data). The existing permit has the following monthly average limits: 11.0 mg/L BOD (16.5 mg/L daily maximum), 30 mg/L TSS (45 mg/L daily maximum), 0.5 mg/L NH3 as N for summer and winter (2.90 mg/L and 7.15 mg/L daily maximum for summer and winter respectively), and 200/100 mL fecal coliform (400/100 mL daily maximum). The plant has a daily maximum chlorine residual limit of 0.024 mg/L. The trunk sewer will ultimately be beneficial to the area by reducing the number of septic systems in use as aging systems begin to fail. A study conducted in 2012 (see attached document) analyzed the failure rate of septic systems within the Goose Creek Basin. Although the failure rate was determined to be low, it was established that septic system failures are happening within the Goose Creek Basin. It is anticipated that as these septic system continue to age that the failure rate will increase. There is an established need for residential sewer service in the immediate project area, and Charlotte Water has been receiving requests from homeowners currently on septic systems that would like to connect to the sewer system. The main request has come from residents in the Farrington Oaks subdivision but Charlotte Water cannot take applications and tap fees until an existing system is in place and close enough to extend service. Ultimately these homeowners will be able to make connections once the trunk line is in place and sewer street main extensions can be installed to meet these requests. Additionally, several developments are slated within the Stevens Creek basin. The availability for sewer connections within these developments will reduce additional septic systems being installed. Another goal for Charlotte Water is to reduce the number of existing pump stations in the area by constructing a regional pump station known as the Stevens Creek Lift Station. This will provide a basin wide pump station for the service area that will send sewer outside the Goose Creek basin to be treated at the McAlpine Creek WWTP, Permit NC0024970. While these improvements may not be defined as mitigation for the buffer, they will reduce existing point source discharges now and in the future. Mitigating Effects of Sewer on Stream • Reduction in septic systems that fail as they age which can in turn cause an increase in TMDLs on the stream. Septic issues are further referenced in Tetra Tech, North Carolina Piedmont Nutrient Load Reducing Measures Technical Report, September 2013, prepared for NCDEQ. Under Section 3 Remedy Malfunctioning Septic System, the report includes making connections to permitted NPDES sewer systems as a means to remove nutrient loads to nearby surface waters. A TMDL of 200/400 cfu (NC Standard for Class C waters) is being targeted. The below information from the NC DEQ Total Maximum Daily Loads for Fecal Coliform for Goose Creek, North Carolina Final Report (2005) summarizes the waste load allocations for Goose Creek. Section 2.2.1 of the report also cites failing septic systems a significant contributor to TMDL increases with the Goose Creek Basin having a specific failure rate of 2.4%. • NC DEQ Total Maximum Daily Loads for Fecal Coliform for Goose Creek (Page iv) 3. Allocation R"atershed/Stream Reach Segment 13-17-18a Wasteload Allocation (DVLA): 7.81x101' counts Load Allocation (LA): 1.14x101; counts Margin of Safety (MOS): More stringent geometric mean target of 180 counts 100 mL. as opposed to the 200 counts 100 mL standard: conservative modeling assumptions. TMDL (W'LA—LA—MOS): 1.22 x 1014 counts TMDL Component TN1DL Allocation Category Fecal Coliform Load Reductions Wasteload Allocation MS4 9_'.5°b Load Allocation von oust Sources 9_'.5°0 Wasteload Allocation Pernnited NXI'%TP's V A Segment 13-17-18b Wasteload Allocation (XVLA): ?.34x1013 counts Load Allocation (LA): ?.06x101' counts Margin of Safety (MOS): More stringent geometric mean target of 180 counts 100 mL_ as opposed to the 200 counts 100 mL standard: consen•ative modeling assumptions. TNiDL (IA-LA—LA—MOS): 2.08x1015 counts TMDL Component TMDL Allocation Category Fecal Coliform Load Reductions Wasteload Allocation MS4 92.5% Load Allocation Nonpoint Sources 92.5% Wasteload Allocation Pennnited R-X%TP's V A • Removal of point source discharge by decommissioning the existing PWWTP after trunk sewer is activated for service. • A reduction in pump stations will limit potential failures and demands of operating multiple stations. Alternate Mitigation Plan As part of this project variance request, we propose that the stream restoration be included as mitigation for the sewer construction mitigation requirements. Stream restoration is inherently a form of mitigation that is intended to restore a watershed to a functioning ecosystem that returns natural rates of ecological, chemical, and physical processes not found in the existing stream. The stream restoration will return the stream to a more natural state by creating stable pattern, profile and dimension, improving aquatic habitat, increasing floodplain connectivity, and establishing native plant species. Buffer areas, excluding the sewer maintenance corridor, disturbed during construction will all be restored with native species while also reducing invasive plant species. The sewer maintenance corridor will be planted with a riparian seed mix that includes grasses and wildflowers native to the area. Mitigating effects of these improvements will provide net watershed benefits that include the following: • Stream restoration will have mitigating effects that improve water quality by reconnecting the stream to the floodplain. • Existing buffer areas will be improved with native species plantings. • With support from US Fish and Wildlife Service, this stream restoration includes habitat structures for aquatic species. The restoration work will improve overall habitat and biotic reliability in the riparian zone. • Stream restoration will reduce the effects of erosion prevalent in the existing incised channel by creating a more stable channel with appropriate dimensions for various flow regimes and gentler slopes. This will mitigate the effects of erosion on water quality by providing a stable bed and riparian zones that promote vegetative growth. • Reference Study Data: Tetra Tech, North Carolina Piedmont Nutrient Load Reducing Measures Technical Report, September 2013, prepared for NCDEQ includes a section, 7 Stream Restoration/Enhancement, on the mitigating effects of restoration on nutrient loads to downstream surface waters. • Stream restoration connectivity to the existing floodplain will change based as shown on Table 1. As you can see, in the existing conditions smaller flood events, typically 2-10 year storms, never reach the floodplain and are thus disconnected from the riparian zone. The upstream reach on Stevens Creek from the confluence with the tributary has the largest stretch outside the 100 -year flood zone. As a result of the project, the stream will access the floodplain at less than a 2 year event. In the current state of the stream, it is accessing the floodplain at a 10-25 year event. As part of the project, the flood width for flood events is being increased up to a 10 - year event. For the tributary and upper portions of Stevens Creek, because of grading to a lower floodplain, the streams will have higher flood capacity at lower elevations. See Table 1 for flood conditions at various return periods. 3a. Is buffer restoration or enhancement proposed? Yes. We have included a Stantec's planting plans for restoration of the buffer areas. The sewer maintenance corridor is specified as follows... Riparian Buffer Seed (sewer maintenance corridor) 1. Riparian seed mix shall be applied along 15 -foot wide maintained easement corridor outside landscaped lawn areas and pastures. 2. Riparian seed mix shall be composed of native spices intended for the North Carolina piedmont region. Approved seed mix includes Ernst Seeds NC Piedmont Riparian Mix or approved equal. 3b. is payment into a buffer restoration fund proposed? No. We are requesting that the responses under question 3 and 3a be consider as mitigation in lieu of payment for mitigation. However, a mitigation request has been made to the NC Ecosystem Enhancement Program for a 15' wide maintenance corridor through existing buffer areas. An acceptance letter will be provided at a later date to be used if necessary to meet permitting requirements. Table 1 Stream Restoration Connectivity 2year flood Existing Proposed Flood Width flood Width Change in Flood Stage 5year flood Existing Proposed flood Width Flood Width Change in Flood Stage 10year flood Existing Proposed flood Width Flood Width Change in Flood Stage 25year flood Existing Proposed Flood Width Flood Width Change in flood Stage Soyear flood Existing Proposed Flood Width flood Width Change in Flood Stage 100year flood Existing Proposed Change in Flood Width Flood Width flood Stage Stevens Creek jabove confluence 19 27 0.4 26 43 -0.6 46 55 -1.1 156 83 -1.3 189 115 .1.2 216 159 .1.2 Stevens Creek lbelow confluence) 30 53 1.3 86 171 0.5 222 246 0.2 288 285 0.1 321 322 0.1 350 341 0.1 Tributary to Stevens Creek 17 21 0.1 23 31 -0.1 27 36 -0.3 105 65 -0.5 148 124 .0.4 182 160 .0.4 \ I � I 1 I � I � I � I � I v .--- - BEGIN REACH 1 STA. 10+00LO YARMOUTH ROAD o INVERT 100"X136"CMP IN j.100" 136" MP ELEV=657.70 ELEV=@57. _ \ ID 19 2 4 MIC ARI MCFALL B 23235 PG 890 d— LOT 30 BMs 665 P D # 9516205 / �13 21 PG 957 IN EASEMT T 0 I I 30' PUBQ STORM A ON K FORSYTH TIE IN EXISTING TRIBUTARY I i & ASHLE E FORSYTH I DRAIN EASEMENT Y Y — ALE10FROM I 298 660 CHANNEL SCALED F I OOK AGE 363" /I M P B4O0 21 PAG 363" / / j Pll�#1 516206 I I --LOT � STEVE M DAMS & g 7 J�6EP LBER ZONE 2B - PIEDMONT ALLUVIAL 0 °' DB 1 279 90 FOREST (SEEDING ONLY) (TYP.) 1 In . iI 3p–� — ��� q//'/ #% / MB 21 PG 7b A 3Msd v RT 1 36"CMP Ol ' PID 1951 CAPI E 1 16207AN / b3MsdELEV=657.59 = PROPOSED THALWEG EXISTING 1a" Opp n TARRA G DEA DB PG 77THALWEG =&JASON C DEAN 33�I INVE T-658.99\ I DB 12272 PG 728 B 2 PINERTI1 0"X13 MP_LOT 341 A65+48 EV o .� - MB 21 PG 954 \ r A65+1 EXISTING �� 3nnsll I TIE IN EXISTING STORMWATER I sa � \ � � �; {� \ S=—�\\ ` — / l b Tie `� ( CONCRETE -- CHANNEL I �� BRIDGE �'d� �sd� sa— ��sd o ----- 3Msd PROPOSED BANKFULLAr wx I I0 SCY 0` \ o _ 301 3n5 �- � � _���---- V 301 \ ( \ \ 0 I 0 0 1 0 \ '4 ------------------------------301 301 301 0 301 71 301 - _- 3Sd' /0 0 0 �� OXO /--------- L- ----------------- 301 301 301 301 301 _- - n 3n ` bnsd------- ---— -- -- 3�1 3a� — g6+00 / 3nsd ° ________ __ A n�a /-------------- 3nsd __ ------ ------ - d 3nsd _ 3Msd / � 3M -------------- 3nSd 3Jys/a/ \\ \ \ I ---------------------- - - ----- _-3 Sd -__-_- n �---------- _---—/ �+00 ins 3nsd 3 d � I 301 301 301 / 1 --- / A62+00 3nsd A +00 A60+00 ( �, 3n d PROPOSED SITE 3nsd 3nsd +p0 / SITE ACCESS A59+00 l � � ACCESS � 3nsd A5$ (PROPOSED 3Msa 3M ZONE 2A - PIEDMONT ALLUVIAL FOREST (TYP.) 3n sd ' STAGING AREA W 3Msa sd 3M 660 PROPOSED SEWER sa sd a 1 / I _ sM�\ LINE (BY OTHERS) 3M 3Msd 3""s%�� PROPOSED TEMPORARY 1 ZONE 2B PIEDMONT ALLUVIAL 3Msd 3M / Msa ��/ CROSSING \ I FOREST (SEEDING ONLY) (TYP.) \ 3Msd 3Msd — _ / I ZONE 1 - STREAMBANK PLANTING (TYP.) bbd I / i LEGEND i -- --- --- -- ����` \ PROPOSED THALWEG EXISTING WETLAND — PROPOSED BANKFULL -__-- / / EXISTING MAJOR CONTOUR PROPOSED GRADING LIMITS EXISTING MINOR CONTOUR — — PROPOSED SITE ACCESS — — —XXXXXXX— EXISTING FENCE LINE PLANTING ZONES EXISTING THALWEG ZONE 1 -STREAM BANK PROPERTY LINE ZONE 2A - PIEDMONT / \ o 0 o EXISTING TREE TO REMAIN ALLUVIAL FOREST 012"-18", 19"-24",-30", 25" 30"+ ( ) ZONE 2B -PIEDMONT ALLUVIAL / \ PSUE PROPOSED PERMANENT SEWER FOREST (SEEDING ONLY) EASEMENT — — — — TICE PROPOSED TEMPORARY — — — — — ZONE 3 - WETLAND FOREST SEWER EASEMENT / PROPOSED STORMWATER ZONE 3 -WETLAND FOREST � PSWE (SEEDING ONLY) EASEMENT 907o DESIGN NOT FOR CONSTRUCTION N O O 0 X 0 20' 40' 80' 1 ''=40' N .j cai E 0 U P � N U N U Permit -Seal E 0 Ln0 c 0 o N 0 � U N � U 0 z Q _N Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. # Revision Sheet 0 56 of 73 0 U C3 O z r � a a 0 '3 c Q U ° o N � C '^ O E a° C) o a 0— NM c') of OQ N D N N Q °76 ° c } — 00 04 3 ° 0011? > Ua 3 N c .O o ° , 'N D 3 ca a - ° E c U E: o � 0 0 0 o > a s ~ 0 U U C o o a Q Z H Q 5 i } O N C ° `c N z 3 aT o o 0 0 U -o U N U ° °' o o c 0 o N 0 � U N � U 0 z Q _N Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. # Revision Sheet 0 56 of 73 ao O U U R z a � 9 C3 i oLM Q� 6 c 'a O U .o 00 In 00 M CD � M o N U a) a o >^ 0�.: So, I I I - - I - � I ePUB IC STORM - - IN RA SEMEN T 0 CALED ROM _ MAP BO 21 PAGE 957" 0 , , PID9516203 / WI IA E GENET JR / I / 0576 PG 6 LOT -2-9 21 PG 7 !- 4 L� PID #19516202 UANN M JENKINS nR -�aa4 PG 531 TIE IN EXISTING STORMWATER ?8 CHANNEL 957 - - YARMOUTH ROAD 0 ' O PROPOSED THALWEG I U PROPOSED BANKFULL EXISTING MAJOR CONTOUR PROPOSED GRADING LIMITS - — — PROPOSED SITE ACCESS —xxxxxX X ' I I I I EXISTING THALWEG a U N O I �I ZONE 1 -STREAM BANK 2 PROPERTY LINE ZONE 2A - PIEDMONT 15' PUBLIC STORM DRAIN' BASEMENT CALED FROM �P BOOK ' O O OOg0 PID5173 ROBI C RR LL WI IAM M RROLL B 23168 P 560 LOT 43 MB 22 PG 30 �j o J \\ PID #19516201 CHAEL P GOLIK 18649 PG 969 LOT 27 PID #19517145 �1 ALEX P LECLAIR & �iD PID 19517144 / O a / 1B 21 PG 957 MARGARET_ HYNE BIGHA SAUNDRA LECLAIR \ FES 30" RCP # y' /� % ,yx & LYNDA BIGHAM EVANS DB 7636 PG 613 RONDA S AVILA / o , , R INVERT=649.32 ti > / , p \ DB 23069 PG 139 \ NDB - DB 27507 PG 32 LOT 45 / �f `N d� LOT 46 MB 22 PG 303 LOT 44 // / .N�� �M d MB 22 PG 303 MB 22 PG 303 I / / �� \ s / � N� � � SJ,/ / `N�� d I ' 1 �� � � A54+0 `� � '^ s ' , s \ . I TIE IN EXISTING TRIBUTARY ` V L CHANNEL sd � \ rZ PROPOSED THALWEG s .�_ s� �� TIE IN EXISTING \`s:.�J/ / sd STORMWATER ��� / CHANNEL �� a ` o .s \ ��s '4S x � �a � TIE IN EXISTING TRIBUTARY \ 00 ��� T� � , CHANNEL I V 1 o EXISTING \ d � � THALWEG sd SITE ACCESS a ° b \ ���s I 4 28+00 NN 2x _ _ , ® ZONE 2B - PIEDMONT ALLUVIAL \ \ SMs a O %I N s \` I PROPOSED BANKFULL 3s1 3�1 3�1 �/� a \ FOREST (SEEDING ONLY) (TYP.) N1311,v� / 1 I S Z - / / o \ °NN _ ) ° \ \ 4S1 x0NN \ ��� \ O 5 11 `. _ _ \ \ Sd _ _— -�t5s� / / / 3n� _ ZONE 2A - PIEDMONT +00 / / / / _ ALLUVIAL FOREST (TYP.) \ '-,�s qs0-NN 1 ZONE 1 - STREAMBANK PLANTING (TYP.) A49+Q0 3nsa � LEGEND ansa PROPOSED SEWER LINE (BY OTHERS) , bb Zz675 680 N 90% DESIGN NOT FOR CONSTRUCTION u f 00 Z 0 0 N ai i Q) O U 0) a� U N U � Permit -Seal PROPOSED THALWEG EXISTING WETLAND U PROPOSED BANKFULL EXISTING MAJOR CONTOUR PROPOSED GRADING LIMITS EXISTING MINOR CONTOUR — — PROPOSED SITE ACCESS —xxxxxX X EXISTING FENCE LINE PLANTING ZONES o '3 Q EXISTING THALWEG a U N O ZONE 1 -STREAM BANK 2 PROPERTY LINE ZONE 2A - PIEDMONT 1 O 000 EXISTING TREE TO REMAIN J ALLUVIAL FOREST (12"-18",19"-24", 25"-30", 30"+) ZONE 2B - PIEDMONT ALLUVIAL PROPOSED PERMANENT SEWER Q L -a N FOREST (SEEDING ONLY) PSUE EASEMENT — — — — — o ao } c - p PROPOSED TEMPORARY — — — — — ZONE 3 -WETLAND FOREST TCE a`o L SEWER EASEMENT PROPOSED STORMWATER m c U ZONE 3 -WETLAND FOREST PSWE EASEMENT (SEEDING ONLY) ansa PROPOSED SEWER LINE (BY OTHERS) , bb Zz675 680 N 90% DESIGN NOT FOR CONSTRUCTION u f 00 Z 0 0 N ai i Q) O U 0) a� U N U � Permit -Seal �o 0 Z 0) Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. # Revision Sheet 57 of 73 T 00 0 U C3 O a 0 0 0 -0 o '3 Q a U N O 2 O c O U a 4L- C E O 5 E o a_ a C) o a o N _ Q T a t 00 Q L -a N N C/)nQ 76 N o ao } c - p O 04 R, 3 o > O a`o L m c U E a O C N o O p@ o > a A U C R 0 0 ° a Z N N 2- a Q 5 a i `c Q p N c a `c N Jz 3 0T _ o o 0 0 U-0 U C'4U ° ° ° Z5 Z5 �o 0 Z 0) Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. # Revision Sheet 57 of 73 T 00 3 m pN O 00 PID #1951714 MERCEDES ORTE�A DB 31897 PG 742 LOT 42 MB 22 PG 303 10' PUBLIC STORM DRAIN EASEMENT "SCALED FROM MAP BOOK 22 PAGE 303" PID #19517141 JAMES T BOYLES JR & ROBIN W BOYLES DB 13846 PG 682 LOT 41 MB 22 PG\303 LEGEND 20' PUBLIC STORM -DRAIN EASEMENT-- ------ SCALED FROM MAP BOOK 22 PAGE 3 3" PID #19517139 DAVID L COLE & PID #1951714 TERESA A COLE JERRY M MUSSELWHI JR DB 8131 PG 67 & SHERRI H MUSSELWITE LOT 39 G 30 DB 9277 PG 598 LOT 40 MB 22 PG 303 11 / ' h S S6 KGF' 1 ( I VERT=647.52 1 i I I � I I 1 sd PID #19517138 PAMELA SULLIVAN & KENNETH AUBREY TYREE DB 8838 PG 329 LOT 38 MB 22 PG 303 i i i i I TIE IN EXISTING STORMWATER 3M CHANNEL A / a 3MS �Msd 3MSd � PROPOSED THALWEG o r (D3MSd 00000, — 3�1 650_--- _ ZONE 1 - STREAMBANK PLANTIN�(TYPJ ��Sd Z 3,js / J/''/',,,,, A��k�� 3056 N 3,j 3'ni 3�sa 655 660 'Ars 3�Sa 665 670 675 3�x00 1 Y100 SITE ACCESS / PID #19517137 JENNIFER BROWER DEGROAT DB 7455 PG 271 LOT 37 MB 22 PG 303 / - EXISTING THALWEG / / / / i PID #19517136 RONALD L PUTNAM DB 8006 PG 291 LOT 36 O MB 22 PG 303 \, / / PID #19517135 MEGHAN GAFFNEY & / MICHAEL A MITCHELL DB 25110 PG 329 LOT 35 MB 22 PG 303 / ZONE 2A - PIEDMONT ALLUVIAL FOREST (TYP.) / PID #19517134 LYNN A PERRY & JASON R PERRY DB 31059 PG 586 LOT 34 MB 22 PG 303 \ I \ ------------------- IL \ I \ \PROPOSED BANKFULL I J PROPOSED SEWER 11)� LINE (BY OTHERS) 42+00 3�1 _ 3313 — _ _ — 3�1 A35+00 G � -- nd \ — � o A3 o 4+ 3+0n TIE IN EXISTING TRIBUTARY �A32+00 I I I I I I ) 1 / �✓� ZONE 213 - PIEDMONT ALLUVIAL— / CHANNEL i ansa 0 /FOREST (SEEDING ONLY) (TYP.)— � \ — J / / \ bbP 90% DESIGN NOT FOR CONSTRUCTION PID #195171 MICHAEL BRADLE' & NOREEN A DB 8702 P LOT 3 0 20' 40' 80' 1 "=40' IN IN IN u (1) 4Jc 4J tn N .j c� N E O C/) U 0 4.-� U N U � Permit -Seal E O O c O i O Ln Q) U c O N cn PROPOSED THALWEG EXISTING WETLAND U PROPOSED BANKFULL EXISTING MAJOR CONTOUR PROPOSED GRADING LIMITS EXISTING MINOR CONTOUR — — PROPOSED SITE ACCESS —XXXXXXX— EXISTING FENCE LINE PLANTING ZONES EXISTING THALWEG ZONE 1 - STREAM BANK PROPERTY LINE ZONE 2A - PIEDMONT ° o o EXISTING TREE TO REMAIN ALLUVIAL FOREST (12"-18", 19"-24", 25"-30", 30"+) ZONE 2B -PIEDMONT ALLUVIAL PROPOSED PERMANENT SEWER FOREST (SEEDING ONLY) PSUE EASEMENT — — — — — C) PROPOSED TEMPORARY — — — — — ZONE 3 - WETLAND FOREST TC E O_ T O t N Q SEWER EASEMENT 0O Q L a N D PROPOSED STORMWATER ZONE 3 -WETLAND FOREST PSWE EASEMENT (SEEDING ONLY) 3�x00 1 Y100 SITE ACCESS / PID #19517137 JENNIFER BROWER DEGROAT DB 7455 PG 271 LOT 37 MB 22 PG 303 / - EXISTING THALWEG / / / / i PID #19517136 RONALD L PUTNAM DB 8006 PG 291 LOT 36 O MB 22 PG 303 \, / / PID #19517135 MEGHAN GAFFNEY & / MICHAEL A MITCHELL DB 25110 PG 329 LOT 35 MB 22 PG 303 / ZONE 2A - PIEDMONT ALLUVIAL FOREST (TYP.) / PID #19517134 LYNN A PERRY & JASON R PERRY DB 31059 PG 586 LOT 34 MB 22 PG 303 \ I \ ------------------- IL \ I \ \PROPOSED BANKFULL I J PROPOSED SEWER 11)� LINE (BY OTHERS) 42+00 3�1 _ 3313 — _ _ — 3�1 A35+00 G � -- nd \ — � o A3 o 4+ 3+0n TIE IN EXISTING TRIBUTARY �A32+00 I I I I I I ) 1 / �✓� ZONE 213 - PIEDMONT ALLUVIAL— / CHANNEL i ansa 0 /FOREST (SEEDING ONLY) (TYP.)— � \ — J / / \ bbP 90% DESIGN NOT FOR CONSTRUCTION PID #195171 MICHAEL BRADLE' & NOREEN A DB 8702 P LOT 3 0 20' 40' 80' 1 "=40' IN IN IN u (1) 4Jc 4J tn N .j c� N E O C/) U 0 4.-� U N U � Permit -Seal E O O c O i O Ln Q) U c O N cn 0 4- 0 Z Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. # Revision Sheet 0 58 of 73 0 U C3 O 0 0 0 0 -0 o '3 a Q U 0 O O c O U 0 � C � O E o 0. 0 C) o a o N cl)_ O_ T O t N Q 0O Q L a N D N C/) r 76 N} Q N a O c p O 04 = 0-N 3 0 > O 0`o L 'N D 3 O a �� 0 m 0 c U E 0 0 C N o O po > 0 -L ~ O U U C ON o o a Q Z H Q C p o o i } o `co a� `c300 N-0 0 0 0 -o Gt R cv U o 0 4- 0 Z Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. # Revision Sheet 0 58 of 73 / / o O \ / / / ZONE 2B - PIEDMONT ALLUVIAL \\ "\ FOREST (SEEDING ONLY) (TYP.) C2+ 5 - — — — — — — \ \ \ -- PID #19517132 DEAN G H KINS & __________ KELLIE P HA S 24274 PG 10 LOT 32 pQ 22 PG 30 \\ \ I Tq 1000 / _ : / 10' PUBLIC STORM /oo b rc DRAIN EASEMENT F 5 "SCALED FROM MAP BOOK 22 PAGE 303" \ b / TIE IN EXISTING STORMWATER CHANNEL \ FES INVERT IT E ELEV=639.80 I E \ 41 sUNNAMED TRIBUTARY b"d TO STEVENS - REACH 6 \ 3MSd %00ov n`SdC 3� Sd \ Y_ / SITE ACCESS otot c ` B0+00 \ a' � \ d ` P II D_�'�951715 sns \ MEsa^R *�NSJR \ ZONE 3B - WETLAND FOREST (SEEDING ONLY) (TYP.) \ a \ 301 ten`\`�Msd �/ \ �s°0 s a \ �sv d ZONE 3A - WETLAND FOREST (TYP.) 5a \ �\y o d \ d 1 / �Jq PROPOSED \22x00 1a THALWEG °S �� \ GF 0 i TSF C1+00 F � / xoo ++00 QUO 'ell ell / ^cell, lo, ZONE 1 - STREAMBANK PLANTING (TYP.) \\\ 0 P. X LEGEND 0 PROPOSED THALWEG EXISTING WETLAND PROPOSED BANKFULL EXISTING MAJOR CONTOUR PROPOSED GRADING LIMITS EXISTING MINOR CONTOUR — — PROPOSED SITE ACCESS —xxxxxxx— EXISTING FENCE LINE PLANTING ZONES EXISTING THALWEG ZONE 1 -STREAM BANK PROPERTY LINE ZONE 2A - PIEDMONT O c O U \\c)o EXISTING TREE TO REMAIN ALLUVIAL FOREST O (12---18--,19---24--, 25"-30", 30"+) ZONE 2B - PIEDMONT ALLUVIAL C) PROPOSED PERMANENT SEWER FOREST (SEEDING ONLY) PSUE EASEMENT — — — — — PROPOSED TEMPORARY — — — — — ZONE 3 -WETLAND FOREST TC E N CV SEWER EASEMENT a } c— 5 04 PROPOSED STORMWATER ZONE 3 -WETLAND FOREST PSWE EASEMENT (SEEDING ONLY) b1p PROPOSED SEWER LINE (BY OTHERS) `7� b NO lo, b1 O i P16 9 241 1 ECKL WUNTY \D 0�snsd \ \ 12 g 4 ��\q P � ? � �" www.----- ` 52+00 Sd � o < ° \ } \\ PROPOSED BANKFULL 1 ZONE 2A - PIEDMONT ALLUVIAL FOREST (TYP.) % - \ 90% DESIGN NOT FOR CONSTRUCTION 1 -- - - + \\ 1 ► w ► 1 Z X, 1 l \ 00 \640 \4� Ob 660 N -------- --------- 0 20' 40' 80' 1 "=40' N N c(D >Q) E O cn U P � N z U N U Permit -Seal c O i O � 0 N o O U N � U o <„ Z Q _N C/7 Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. # Revision Sheet 0 59 of 73 0 U C3 O a 0 0 0 -0 o '3 a Q U N O O c O U a � c � O E o a_ a C) o a o N M Q T p t o Q Q t a N CV a } c— 5 04 0011? CUP o > O a 3 'o .N D 3 O a 'o ca c U E: a CE) C N - o _r O 0c o >C a� -L 1.0O �? U o a a Q Z H Q a oo2EQ i `c-_ Q O N C 'c O T `c N z 3 a 0 o o 0 U o U cv U r- z -r- o c O i O � 0 N o O U N � U o <„ Z Q _N C/7 Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. # Revision Sheet 0 59 of 73 3 m N g 00 0 x ansa 645 1 1 ---------- 1 1 / 1 1 ZONE 2B - PIEDMONT ALLUVIAL _ 3nsa FOREST SEEDING ONLY TYP. 1 1 l ansa / t it � r d 0 �d I AVS — ansa 0L�jl � \` `� I I 41S6 3 ��� :gid �'�Sd PROPOSED SEWER -301 LINE (BY OTHERS) i PROPOSED ACCESS ALONG _ _ ' 640 \ +00 ansa i 301 ��� �0 \` i I EXISTING NATURE CENTER MAINTENANCE ROAD \ 301 \ `.` �Sd s PROPOSED ansa 3Di ��i d SITE ACCESS\3nsd— (D '- 301 3 3nsd i 3 \ 3j �� des `�\ I 1 3nsd 3nsd_ — 30 1 a '4r 3nsd - \��\\ `�4 `DO �sd �nsd I 3nsd _ "J/V3nsd 8 +0 \`�\\ I I A11+00 3nsd __3ns____ —---J------------------------------- ------ 3nsd 3�1-----3�1--------- ___ ____------ - 3FlSd _ 34&4 `-------_—__ 3�1 3�1--------- 301 END REACH 2 � _b � � 3ras� L____ --------- 301 301 01 1 ��` ��Sd 3nsd __--- I 1 301 �l _ 635 BEGIN REACH 3 __ ___ - 301 -T— a ---- \� STA. 60+68 \ \ � `�— — ---- 3-1 ----- -- 3�1 301 i — 3�1 3�1 3 I I ° \ I ------r---T------- --- I ' PROPOSED <I LEGEND a EXISTING THALWEG,t - \� \ �y + \ ; \ C) \ \ \ PID #19524101 \ , PLUG EXISTING {\ CHANNEL (TYP.) ° I TIE IN EXISTING TRIBUTARY CHANNEL I STAGING AREA I 1 I 1 PID #19524101 MECKLENBURG COUNTY DB 12412 PG 394 ZONE 2A - PIEDMONT ALLUVIAL FOREST (TYP.) o � r PROPOSED BANKFULL PID #19524101 MECKLENBURG COUN DB 12412 PG 394 0r-_� MECKLENBURG COUNTY_ __----- DB 12412 PG 394 \ — --- \ \\ PROPOSED THALWEG 6.80 ° \ \ kip , ------ ` ZONE 1 - STREAMBANK PLANTING (TYP.) PID #19524101 ° MECKLENBURG COUNTY 1 \ a \ / _i / rCN DB 12412 PG 394 `---------- \ \LLJ � _ r L \ \ \ \\ 640 — � \ �\ � \ � � / / ✓- — — — — 645— \ \ I 650 907o DESIGN NOT FOR CONSTRUCTION 0 20' 40' 80' 1"=40' 1 E E I f m N a� O cn D U ri _N � U N U Permit -Seal PROPOSED THALWEG EXISTING WETLAND U PROPOSED BANKFULL < EXISTING MAJOR CONTOUR PROPOSED GRADING LIMITS O < N EXISTING MINOR CONTOUR — — PROPOSED SITE ACCESS <—XXXxxxx— EXISTING FENCE LINE PLANTING ZONES EXISTING THALWEG ZONE 1 -STREAM BANK — — PROPERTY LINE ZONE 2A - PIEDMONT \oo() EXISTING TREE TO REMAIN ALLUVIAL FOREST (12"-18", 19"-24", 25"-30", 30"+) U N ZONE 2B - PIEDMONT ALLUVIAL PROPOSED PERMANENT SEWER FOREST (SEEDING ONLY) PSUE EASEMENT — — — — — PROPOSED TEMPORARY — — — — — ZONE 3 -WETLAND FOREST TC E C) o a NO SEWER EASEMENT Q L a PROPOSED STORMWATER co ZONE 3 -WETLAND FOREST PSWE EASEMENT (SEEDING ONLY) `---------- \ \LLJ � _ r L \ \ \ \\ 640 — � \ �\ � \ � � / / ✓- — — — — 645— \ \ I 650 907o DESIGN NOT FOR CONSTRUCTION 0 20' 40' 80' 1"=40' 1 E E I f m N a� O cn D U ri _N � U N U Permit -Seal 0 O z P. Project Number: 175613085 File Name: 13085C-002-VEG.dwg Dwn. Chkd. Dsgn. YY.MM.DD Drawing No. # Revision Sheet 0 60 of 73 >, m D 0 U z) a)O O N ON O ')(-) 7 o '3 a Q O U N O c O U O C O E o o a 2— C) o a NO Q L a D co o N N (n N Q N a O 0 } O � 0-N 3 2 > t3 � L � -o`o D O 3 O a o m c U i= � o 00 >� Sao O ~ _ O U o o a Q z H o g � oo moo_ Q o "• `c `o 3 a N 3 U -p U O C14U 3 ° (L) �zo 0 O z P. Project Number: 175613085 File Name: 13085C-002-VEG.dwg Dwn. Chkd. Dsgn. YY.MM.DD Drawing No. # Revision Sheet 0 60 of 73 >, m D 3 m g U O M 3nsd 3nsd DDlID/ISED SEWER OTHERS) 3nsd 1% ' ) ----A7±00----------------------A6+00 ---------------------- A5+00_______ 3nsd 3nsd 3nSd 3nsd --------------------------- _ -------------------------------- F-0- 301 301 301 X301 301 301 --r- 301 3U1 SITE ACCESS 301 I I I I I I I I I I I I I I I I I I � I I I I I I 3nsd 301 301 AO+00 P bp') 5jL ZONE 2B - PIEDMONT ALLUVIAL FOREST (SEEDING ONLY) (TYP.) 3nsd k00 4+00 3nsd------------- 3nsd \ / -- ��\ y - 301 331 331 301 \\ \\ 2 \ \ PID #19514101 / \\ \\ MECKLENBURG COUNTY \\ \\ DB 30459 PG 495 O 00 QD 1 PROPOSED BANKFULL 00 � EXISTING THALWEG tiQ Q Do 635GO) 640 (D 645 � LEGEND 0 PROPOSED THALWEG > EXISTING WETLAND PROPOSED BANKFULL EXISTING MAJOR CONTOUR PROPOSED GRADING LIMITS > EXISTING MINOR CONTOUR — — PROPOSED SITE ACCESS XXXXXx- - EXISTING FENCE LINE PLANTING ZONES EXISTING THALWEG ZONE 1 -STREAM BANK PROPERTY LINE ZONE 2A - PIEDMONT ON O') -i7 GOO()GOZf EXISTING TREE TO REMAIN ALLUVIAL FOREST (12"-18", 19"-24", 25"-30", 30"+) ZONE 2B - PIEDMONT ALLUVIAL PROPOSED PERMANENT SEWER FOREST (SEEDING ONLY) PSUE EASEMENT PROPOSED TEMPORARY — — — — — ZONE 3 - WETLAND FOREST TC E O C SEWER EASEMENT PROPOSED STORMWATER ZONE 3 -WETLAND FOREST PSWE EASEMENT (SEEDING ONLY) BTM CULVERT=618. _ \BTM CULVERT=618.7 PROPOSED THALWEG G C00 /, o Y) e--- ,,,, 0 630 16-1-00 (D635 PID #19524101 MECKLENBURG COUNTY bpi DB 12412 PG 394 ZONE 3A - WETLAND FOREST (TYP.) ZONE 2A - PIEDMONT ALLUVIAL FOREST (TYP.) I 907o DESIGN NOT FOR CONSTRUCTION 0 20' 40' 80' 1 "=40' N cn O U a� � U — N U Permit -Seal P. Project Number: 175613085 File Name: 13085C-002-VEG.dwg Dwn. Chkd. Dsgn. YY.MM.DD Drawing No. # Revision Sheet 0 61 of 73 0 U z) a)O O N ON O') -i7 a o '3 a Q O U N O c O U O C O E o D a 2— C) o a NO Q L a coN o N (n N Q N a O 0 } O � a N 3 0 > O � L � -D`o O }Oa o m c Um To z- OU > o 40 O ~ O U _ t - o� a Q z N H e o g Q O "• � `c3 `o I� a O O O N 3 U -a U O P. Project Number: 175613085 File Name: 13085C-002-VEG.dwg Dwn. Chkd. Dsgn. YY.MM.DD Drawing No. # Revision Sheet 0 61 of 73 \\ o" ,moo ----------------- -- ------- ---- u 3nsd ► `'--asp �� 3nsd PARIS FAMILY LLC _630 0i CHEVAL ASSOCIATES LLC PID# 19507103 ► - _-- �- 3nsd PID# 19508131 DB 25497 PG 724 ; ----- 0829+0p 943,8 PG 1 MB 43 PG 573 ,�_ \ MB 44 M BEGIN REACH 5 ` UT TO STEVENS CREEK STA. 100+00 EQUITY TRUST COMPANY PID# 19507105 LOT 2 DB 29642 PG 357 MB 55 PG 900 LEGEND - ► 3�i 301--- � -----___ 3 ZONE 2A - PIEDMONT ALLUVIAL FOREST (TYP.) —828.1. j►1 3��`3�� � _ _-______ \ ---3f4d-___ ' 3nsd 3f1Sd - ► �l 301 - B w� 27+0 /0 03�1�---___ �� ► i - \ 3�1 3� _ 4 B26+00, B �— 1 _ - \ +��� j --------------------------- T 3�1 3�1 3�1 301_ 301 331 - 30ft1 a� THE MEADOWS AT 1% CHEVAL HOMEOWNERS ASSOCIATION INC. PID# 19508152 COS DB 32382 PG 636 MB 56 PG 49 665 61 EXISTING WETLAND � --- 655 3nSd el IEVAL ASSGUIXFES 1-1-6 3nSd PID# 19508131 V . MB 44# - NMI i0 301� o1 31 PROPOSED THALWEG 301 301 731 (DG oplT) 3nsd - ° ° OD o ; .PROPOSED BANKFULL o\ e I � 6� \ ZONE 1 - STREAMBANK PLANTING (TYP.) PROPOSED r'�� STAGING AREA i � � � / � � � � � �o \ � � � (D , -------- r ----T--' I THEA MEADOWS AT j CHEVAL HOMEOWNERS I ASSOCCATION INOv. PID# / I 19 08152 BERNARD ROY i � i -'—/ C -0C PARSON II & KAREN \ D 32382 PG 6—FULLER PARSONS q I I PID# 19508153 q I MB 56 PG 49 MORITZ PROPERTIES LLC 660 -DB 3169f944 PG 706 / i i PID OT 208154 \ MB 56 PG 49- 22 DB 26978 PG 870 MB 56 PG 49 / O 66S 655 PROPOSED SITE ACCESS 731 — - a Q \ 660 / OZULFIQAR ALI TURK & 0� 665 SAIDAA TURK PID# 19508155 �A 90'7o DESIGN NOT FOR CONSTRUCTION 0 20' 40' 80' 1 ''=40'PEI T m U i cn E O cn 4 O U (D U Permit -Seal PROPOSED THALWEG U PROPOSED BANKFULL EXISTING MAJOR CONTOUR PROPOSED GRADING LIMITS EXISTING MINOR CONTOUR - - PROPOSED SITE ACCESS -XXXXXXX- EXISTING FENCE LINE PLANTING ZONES o '3 Q EXISTING THALWEG a U N O ZONE 1 -STREAM BANK 2 PROPERTY LINE ZONE 2A - PIEDMONT \Goo TREE TO REMAIN ALLUVIAL FOREST C O 4L- -30",EXISTING (12"-18", 19"-24", 25" 30"+) 5 E o o_ a ZONE 2B - PIEDMONT ALLUVIAL PROPOSED PERMANENT SEWER Cl)_ FOREST (SEEDING ONLY) PSUE EASEMENT - - - - - Cl)Q PROPOSED TEMPORARY N - - - - - ZONE 3 - WETLAND FOREST TICE O 04 R, 3 0 > O SEWER EASEMENT PROPOSED STORMWATER ZONE 3 -WETLAND FOREST PSWE EASEMENT (SEEDING ONLY) --- 655 3nSd el IEVAL ASSGUIXFES 1-1-6 3nSd PID# 19508131 V . MB 44# - NMI i0 301� o1 31 PROPOSED THALWEG 301 301 731 (DG oplT) 3nsd - ° ° OD o ; .PROPOSED BANKFULL o\ e I � 6� \ ZONE 1 - STREAMBANK PLANTING (TYP.) PROPOSED r'�� STAGING AREA i � � � / � � � � � �o \ � � � (D , -------- r ----T--' I THEA MEADOWS AT j CHEVAL HOMEOWNERS I ASSOCCATION INOv. PID# / I 19 08152 BERNARD ROY i � i -'—/ C -0C PARSON II & KAREN \ D 32382 PG 6—FULLER PARSONS q I I PID# 19508153 q I MB 56 PG 49 MORITZ PROPERTIES LLC 660 -DB 3169f944 PG 706 / i i PID OT 208154 \ MB 56 PG 49- 22 DB 26978 PG 870 MB 56 PG 49 / O 66S 655 PROPOSED SITE ACCESS 731 — - a Q \ 660 / OZULFIQAR ALI TURK & 0� 665 SAIDAA TURK PID# 19508155 �A 90'7o DESIGN NOT FOR CONSTRUCTION 0 20' 40' 80' 1 ''=40'PEI T m U i cn E O cn 4 O U (D U Permit -Seal 0 0 z Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. Revision Sheet 62 of 73 r m C 0 U C3 O a 0 0 0 -0 o '3 Q a U N O 2 O c O U C O 4L- O 5 E o o_ a C) -0-0 oN Cl)_ Q T O t N Q � Q L a N Cl)Q N to 76 N N a O } c - p O 04 R, 3 0 > O o`o L 'N 3 O a ' o m 0 c U E O O C 6 -6 2:E O po @ >2 -oT -L ~ O U U o o a Q i `g Q p N c 0 - `c3 0T 0 o 0 0 cv U N °' ° 0 o 0 0 z Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. Revision Sheet 62 of 73 r m 3 o> N g U 00 0 3nsd 331 301 3nsd 3nsd -- - 3nsd 0 CHEVAL OCIATE d' ---- ;�-- fls,+p —� d----- 3nsd e20+00 301=191 3��30 — Pon_ 3�Sd Sd — 3M / i / i l,� JASON C & X, ANDREA E KNOTTS s PID# 19508157 LOT 219 -29473 PG 495 MB 5&7 49 / r LEGEND 0 PROPOSED THALWEG EXISTING WETLAND C3 O PROPOSED BANKFULL EXISTING MAJOR CONTOUR PROPOSED GRADING LIMITS — EXISTING MINOR CONTOUR — — PROPOSED SITE ACCESS —XxxxxXX— EXISTING FENCE LINE PLANTING ZONES EXISTING THALWEG ZONE 1 -STREAM BANK PROPERTY LINE ZONE 2A - PIEDMONT O c O U o EXISTING TREE TO REMAIN ALLUVIAL FOREST O (12"-18",19"-24", 25"-30", 30"+) ZONE 2B - PIEDMONT ALLUVIAL C) PROPOSED PERMANENT SEWER FOREST (SEEDING ONLY) PSUE EASEMENT — — PROPOSED TEMPORARY — — — — — ZONE 3 -WETLAND FOREST TICE N C/) r" 76 CV} SEWER EASEMENT Qo C3 c – p op O PROPOSED STORMWATER ZONE 3 -WETLAND FOREST PSWE EASEMENT (SEEDING ONLY) u u I I I I I I < 655 PROPOSED STAGING AREA 650 INVERTa 9 CP=63 1 �n5 I 1 \ ZONE 2B -PIEDMONT ALLUVIAL 9 FOREST (SEEDING ONLY) (TYP.) I ZONE 2A - PIEDMONTI u ZONE 3A - WETLAND ALLUVIAL FOREST (TYP.) FOREST (TYP.) �tt 3na ykp0 6 �� J 3nsd 3nsd 3nsd PID #19508105 I ✓ �^�j \ CLAY A LITTLEFIr' _ & JENNIFER LITT B18+00 lmw- DB 309 P -1317+00 d 1316+00 ins sd------- _, 69a -A LLC PID# 19508131 - ' - DB 19418 PG' / ----------------------- — I � 3�1 u 3��''% �sL PROPOSED BANKFULL 301 - 301 301 301 �: a INVERT 84" RCPT _ THE MEADOWS AT — CHEVAL HOMEOWNERS BECKY BOBZIEN-SIMMS & TONEY SIMMS PID# 19508158 LOT 218 DB 30627 PG 990 MB 56 PG 49 Cu u_ u CD �I u F s a '9 k� I VERT ",ORCIP---639.50� 3 f Jo 16 , PID #19 MECKLENBUR � ITY - u DB 24891 862 - 3 r 655/ J J ASSOCIATION INC. Pq# 19508167 INVERT- 84" RCP=640.30 ° �S r , � 0 c DB032 8 'PG 636 bb / o uu u I � u / 6 PG 49 � bbd UNDERGROUND WATERLINE 6So u � / i/ 655 JOHN NTHONY G UE PI 1950815 LOT 22 665 DB 2 53 PG //4 MB 5" u u J 670 0{ u _----- 3MSd — 3MSd 3MSd o ZONE 1 - STREAMBANK PLANTING (TYP.) u 0 SHENARD D BYRD & ,D . u 7 90'7o DESIGN NOT FOR CONSTRUCTION 00000 0 0 8 Q 0 0 0 0 0 0 o I � I 0 0 0 0 I 0 I 0 C] 0 I 0 I 0 I 0 0 I 0 0 I 0 Q I I I / OVERHEAD POWER LINE I I / I � I/ I Q CL � I I / 20 4/ 80 40 ■ ■ N .j c� E O cn u P O � N U U Permit -Seal c O O O N IY N u Q) N (/7 Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. Revision Sheet 0 63 of 73 0 U C3 O O 'D 0 0 -0 0'3 a Q U N O O c O U a � C � O E o 00 C) o a o N _ a T a t o Q 0O Q L a N D N C/) r" 76 CV} Qo C3 c – p op O a a 3 o > O a`o L N o O 5 �N�} O a ' o ca c U E a O C N -6 2� O 0 .E o > a -L ~ O U U C T o o a Q Z H Q a c p o a i } O N C O `c _3 aT o o -o0 0 U � Z5 Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. Revision Sheet 0 63 of 73 3 om ON O U 00 0 3� / ��� 650 / O � l0 0 ZONE 2B - PIEDMONT ALLUVIAL / 0 00 FOREST (SEEDING ONLY) (TYP.) U-1 / I / I / I / I PROPOSED SITE ACCESS 645 / I \Pd ZONE 2A - PIEDMONT ALLUVIAL FOREST (TYP.) 3nS I 3 Sd3nsd 3nsd 3nsd3nSd 3MsdB10+00 I 3M3nsd �Msd ansd B11+OO�sdJMS 3nsd — 3nsd B9+00�d3nsd 3nsd d 3nsd 88+00 301 X ----------------- 3nsd 3nsd - d ------ 67± 0 > ------ - 5 -'0 - -- � � _---------------- - � ------ 3nsd X86+00_ 3 3Msd 3MSd /14 ��_Y 301 3�1 301 301 �1 --___ _ d _PROPOSED BANKFULL Msa 3ns,B5+ - 301 30 - 1 / 301 301 3J1 -- 3-3MSd3�1 ---- -- --- -------__-- w 31Sd dMsd ----___---- ----- -- 301 3=1 7M"53. 301 331 30 y 3�r 3�1 w 1'124+00 , n -cc ,/L �— o o 0 0 E�—E E E E E E E E E w - -�-l- - POWER POLE 61 Insd — 3nsd SBO+00 v i ° J S R DY306 / PB 6 x00 ZONE 3A - WETLAND FOREST (TYP.) 3nsd 3nsd 3nsd � //01 �B4+00-3nsd �3maj=83+003Msd 3MSd /3MS , �7.7 'yr3-' 01 301 231 OVERHEAD POWER LINE w ZONE 1 - STREAMBANK PLANTING (TYP.) w ` I LlI w ZONE 1 - STREAMBANK PLANTING (TYP.) o _ ` I 16 PID #19517147 - _ � � PIIS �1 Q51 71 4R - 90'7o DESIGN 301 NOT FOR CONSTRUCTION b; 1 66 I i i I vso- —` `_.`trz+uu qsG ��E F I E s Cb \ 10 C�\\ 0 40 :0 '0■■■ M _ Gd_ Q� U N cn N E O O U N � Q U - N U Permit -Seal C O L O 0 U V) Q) LEGEND I j PROPOSED THALWEG U EXISTING WETLAND z) a)O PROPOSED BANKFULL EXISTING MAJOR CONTOUR PROPOSED GRADING LIMITS EXISTING MINOR CONTOUR — — PROPOSED SITE ACCESS —XXXXXXX— EXISTING FENCE LINE PLANTING ZONES EXISTING THALWEG ZONE 1 -STREAM BANK PROPERTY LINE ZONE 2A - PIEDMONT o o a EXISTING TREE TO REMAIN ALLUVIAL FOREST o '3 a Q (12-18" 19"-24" 25"-30" 30"+) ZONE 2B - PIEDMONT ALLUVIAL PROPOSED PERMANENT SEWER FOREST (SEEDING ONLY) PSUE EASEMENT — — — — — PROPOSED TEMPORARY — — — — — ZONE 3 -WETLAND FOREST TCE SEWER EASEMENT PROPOSED STORMWATER ZONE 3 -WETLAND FOREST PSWE EASEMENT (SEEDING ONLY) E o 00 2— C) o a NO Q L a coN o N (n I Q N a O 0 } � � a N 3 0 > O � ar � O }Oa o m c U E a`) To 0� ; a O ~ O o U o� a Q Z 90'7o DESIGN 301 NOT FOR CONSTRUCTION b; 1 66 I i i I vso- —` `_.`trz+uu qsG ��E F I E s Cb \ 10 C�\\ 0 40 :0 '0■■■ M _ Gd_ Q� U N cn N E O O U N � Q U - N U Permit -Seal C O L O 0 U V) Q) LEGEND C 0 PROPOSED THALWEG U EXISTING WETLAND z) a)O PROPOSED BANKFULL EXISTING MAJOR CONTOUR PROPOSED GRADING LIMITS EXISTING MINOR CONTOUR — — PROPOSED SITE ACCESS —XXXXXXX— EXISTING FENCE LINE PLANTING ZONES EXISTING THALWEG ZONE 1 -STREAM BANK PROPERTY LINE ZONE 2A - PIEDMONT o o a EXISTING TREE TO REMAIN ALLUVIAL FOREST o '3 a Q (12-18" 19"-24" 25"-30" 30"+) ZONE 2B - PIEDMONT ALLUVIAL PROPOSED PERMANENT SEWER FOREST (SEEDING ONLY) PSUE EASEMENT — — — — — PROPOSED TEMPORARY — — — — — ZONE 3 -WETLAND FOREST TCE SEWER EASEMENT PROPOSED STORMWATER ZONE 3 -WETLAND FOREST PSWE EASEMENT (SEEDING ONLY) 90'7o DESIGN 301 NOT FOR CONSTRUCTION b; 1 66 I i i I vso- —` `_.`trz+uu qsG ��E F I E s Cb \ 10 C�\\ 0 40 :0 '0■■■ M _ Gd_ Q� U N cn N E O O U N � Q U - N U Permit -Seal C O L O 0 U V) Q) 0 0 z 2 P. Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. # Revision Sheet 0 64 of 73 Z) N C 0 U z) a)O O N ON O') �7 o '3 a Q O U N O c O U C O 4L- 5 O E o 00 2— C) o a NO Q L a coN o N (n N Q N a O 0 } O � a N 3 0 > O � ar � O }Oa o m c U E a`) To 0� ; a O ~ O o U o� a Q Z H j a o "• `c `o 3 a O o Ot N 3 U -p U O FN 3 °° _ 0 0 z 2 P. Project Number: 175613085 File Name: 13085C-002-VEG.dwg Drawing No. # Revision Sheet 0 64 of 73 Z) N 0) 3 a U CD 0 LO 00 0 Planting Summary for Vegetative Communities and Zones - Stevens Creek I I~ U 4 m) 7 i3 0 0 , o EQ 3 Streambank (Zone 1), Total Acreage a ■ Cn r Acres 1.54 Species C) Common Name Max Spacing (ft) Unit Type* Size Stratum °� p 0- Special Notes No. of Stems �>- 2Q1-0 -0 Cephalanthus occidentalis** Buttonbush 4 L 0.75 in diameter and 3 ft length Shrub 419 Cornus amomum Silky dogwood 4 L Understory 1,674 Salix nigra Black willow 4 L Understory 2,095 a a 3 a o �: Subtotal 4,189 o o -11 � � a Im C) C U To Piedmont Alluvial Forest (Zone 2a), Total Acreage 0 � o " o >o -0a) 0 U Acres 13.5 Species Common Name Max Spacing (ft) Unit Type* Size Stratum Special Notes No. of Stems C o a a Ulm us rubra Slippery elm lox 12.5 R or C 0.75 in RCD at 6 in above root ball or 1 gal Overstory 353 C4 3 Betula nigra River birch 10 x 1 .5 R or C Overstory 353 Carya ovata Shagbc rk hickory lox 1 .5 R or C Overstory 353 Acer negundo Ash -leaved maple lox 1 .5 R or C Overstory 353 Acer rubrum Red maple lox 1 .5 R or C Overstory 353 Quercus shumardii Shum rd oak lox 1 .5 R or C Overstory 353 Platanus occidentalis Syc more 10 x 1 .5 R or C Overstory 353 Juglans nigra Black walnut 10 x 1 .5 R or C Overstory 353 Cornus florida Flowering dogwood 10 x 1 .5 R or C Understory 469 Asimina triloba Pa paw 10 x 1 .5 R or C Understory 469 Cercis canadensis Re bud 10 x 1 .5 R or C Understory 469 Styrax grandifolius Bigleaf snowbell 10 x 1 .5 R or C Understory 469 Subtotal 4,701 Wetlands (Zone 3a), Total Acreage Acres 0.56 Species Common Name Max Spacing (ft) Unit Type* Size Stratum Special Notes No. of Stems Acer negundo Boxelder lox 12.5 R or C 0.75 in at 6 in above root ball or 1 gal Overstory 28 Betula nigra River birch lox 12.5 R or C Overstory 28 Carya ovata Shagbark hickory 10 x 12.5 R or C Overstory 28 Quercus shumardii Shumard oak 10 x 12.5 R or C Overstory 28 Cornus florida Flowering dogwood 10 x 12.5 R or C Understory 32 Asimina triloba Pawpaw 10 x 12.5 R or C Understory 32 Viburnum dentatum Southern arrowood 5.5 x 6 C 1al g Shrub Shrubs must be planted in groups 40 40 Cephalanthus occidentalis Buttonbush 5.5 x 6 C Shrub Subtotal 254 Permanent Seeding, (Zones 1-2a and 2b), Total Acreage Acres 16.3 Species Common Name Max Spacing (ft) Unit Type* Size Stratum Special Notes No. of Stems Lbs/ac Total Lbs Asclepias tuberosa Butterfly weed NA S NA Herb NA 5 82 Hibiscus moscheutos Rose mallow S Herb 5 82 Andropogon virginicus Broom sedge S Herb 5 82 Dicanthelium (Panicum) clandestinum Deer tongue S Herb 5 82 Panicum anceps Switchgrass S Herb 5 82 Elymus virginicus Virginia wild rye S Herb 5 82 Secale cereale I Rye grain S I Herb 20 327 Setaria italica Foxtail millet S Herb 10 163 Subtotal 60 980 Wetland Seeding, (Zone 3a and 3b), Total Acreage Acres 0.58 Species Common Name Max Spacing (ft) Unit Type* Size Stratu Special Notes No. of Stems Lbs/ c Total Lbs Cephalanthus occidentalis Buttonbush NA S NA Herb NA 3.5 2.0 Chasmanthium latifolium River oats S Herb 3.5 2.0 Elymus virginicus Virginia wild rye S Herb 3.5 2.0 Helianthus angustifolius Swamp sunflower S Herb 3.5 2.0 Lobelia cardinalis Cardinal flower S Herb 3.5 2.0 Mimulus ringens Monkey Flower S Herb 3.5 2.0 Pontederia cordata Pickerelweed S Herb 3.5 2.0 Pycnanthemum tenuifolium Narrowleaf mountain mint S Herb 3.5 2.0 Saururus cernuus Lizard's tail S Herb 3.5 2.0 Solidago nemoralis Gray goldenrod S Herb 3.5 2.0 Secale cereale Rye grain S Herb 20 11.6 Setaria italica Foxtail millet S Herb 10 5.8 Subtotal 65 38 Total 9,144 125 1,018 16.9 *C = Container; L = Live stake; R = Bare root; S = Seed **Only plant Buttonbush along the toe of the stream bank, this planting area is confined to the lowest planting row of live stakes. Note: Stem subtotals shall remain constant but the number of stems per species of within each stratum may vary. Note: Shrubs must be planted in groups more densely around the outer edges of the wetland PLANTING GUIDELINES: • ALL PLANTS WILL BE NATIVE TO THE NORTH CAROLINA PIEDMONT REGION. • INVASIVE SPECIES WILL NOT BE USED IN ANY WATER QUALITY BUFFER REVEGETATION • FOR DISTURBED AREAS WITH SLOPES 3:1 OR GREATER, SOIL WILL BE STABILIZED WITH MATTING OR OTHER APPROVED STABILIZATION METHOD UNTIL PERMANENT VEGETATION IS ESTABLISHED. ONLY 100% BIODEGRADABLE MATERIAL WILL BE USED. • PLANTING ALLOWANCES MAY BE MADE FOR EXISTING TREES. • IT IS RECOMMENDED THAT CHEMICAL FERTILIZERS AND PESTICIDES NOT BE USED IN THE BUFFER DUE TO THE RISK OF STORM WATER POLLUTION. INSTEAD, COMPOST OR ORGANIC MATTER SHOULD BE INCORPORATED INTO THE SOIL, WHICH WILL PROVIDE SUFFICIENT NUTRIENTS FOR ADEQUATE PLANT GROWTH. INVASIVE SPECIES SHOULD BE REMOVED BY HAND CLEARING INSTEAD OF USING PESTICIDES. • PLANTINGS SHOULD OCCUR AT THE APPROPRIATE TIME OF YEAR TO PROMOTE SURVIVABILITY. IN MECKLENBURG COUNTY, THIS IS TYPICALLY FROM NOVEMBER THROUGH EARLY MARCH. • 10% OF THE TREES PLANTED ARE TO BE CONTAINERIZED, THE REST ARE TO BE BAREROOT. • CONTAINERIZED TREES SHALL BE EVENLY DISTRIBUTED THROUGHOUT THE PROJECT SITE. NOTES: • NO SEED SHALL BE PLACED ON COMPACTED SOIL. PRIOR TO SEEDING, THE SOIL SHALL BE SCARIFIED TO A MINIMUM DEPTH OF 4 INCHES. ALL SEEDING AREAS SHALL BE COVERED WITH STRAW MULCH AT THE RATE OF 1-2 TONS PER ACRES. • TEMPORARY SEEDING SHALL BE APPLIED ON ANY DISTURBED AREAS TO REMAIN UNTOUCHED FOR MORE THAN 14 DAYS. PERMANENT SEEDING SHALL BE INSTALLED WITHIN 15 WORKING DAYS OF CONSTRUCTION COMPLETION. • FOLLOWING BUFFER RESTORATION, DIFFUSE FLOW WILL BE MAINTAINED THROUGH THE BUFFER IN PERPETUITY • IT IS RECOMMENDED THAT CHEMICAL FERTILIZERS AND PESTICIDES NOT BE APPLIED IN THE BUFFER • ALL PLANTS WILL BE MAINTAINED IN PERPETUITY AND WILL BE REPLACED AS NECESSARY TO ENSURE THAT THE ORIGINAL PLANTING DENSITY IS MAINTAINED. • FOLLOWING THE COMPLETE INSTALLATION OF THE APPROVED WATER QUALITY BUFFER REVEGETATION PLAN, A FINAL INSPECTION AND WRITTEN APPROVAL MUST BE MADE BY CHARLOTTE-MECKLENBURG STORM WATER SERVICES. CALL (704) 336-5456 TO SCHEDULE A FINAL INSPECTION. • IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO MAINTAIN THE REVEGETATED SITE AND REPAIR, PROTECT, AND ADD ADDITIONAL CONTROLS TO PROTECT THE BUFFER AS NECESSARY AT THEIR SOLE EXPENSE DURING THE WARRANTY PERIOD. \ ' BANKFULL 1 tiQTy POOL 1.. •• L I 11P �/TAA .• / S RIFFLE THALWEG TO Q/ LOW FLOW WATER SURFACE POOL ••' •'1 LIVE STAKES BUDS (FACING UPWARD) BASAL END CUT AT 450, 1/2" TP 1-1 /2" IN DIAMETER LIVE STAKES INNER BERM I - 1 LIVE STAKING 65 NOT TO SCALE PROPOSED STREAMBED Cf 6" MIN. - HORIZONTAL OVERLAP VERTICAL OVERLAP 7' ITVDI 700 g/m2 COIR FIBER MATTING 6" MIN.J HORIZONTAL OVERLAP MATTING STAKING VIEW 2 MATTING, TYPICAL 65 NOT TO SCALE 1. INSERT PLANTING BAR AS SHOWN 2. REMOVE PLANTING BAR AND PLACE AND PULL HANDLE TOWARD SEEDLING AT CORRECT DEPTH. PLANTER. 4. PULL HANDLE OF BAR TOWARD PLANTER, FIRMING SOIL AT BOTTOM. 5. PUSH HANDLE FORWARD FIRMING SOIL AT TOP. DIBBLE PLANTING METHOD USING THE KBC PLANTING BAR (FOR FLOODPLAIN BUFFER PLANTING AND UPLAND BUFFER PLANTING) 3 PLANTING LINEAR BAREROOT 65 NOT TO SCALE 2' LONG 1"x 2" WOOD STAKES w/ 2" GALVANIZED ROOFING NAIL AT THE TOP TO HOLD MATTING I� BKF ELEVATION PROPOSED GROUND NOTES: 1. LIVE STAKES SHALL BE INSTALLED WHERE INDICATED ON THE DRAWINGS AND DETAILS. 2. LIVE STAKES SHALL BE CUT FROM AN APPROVED SOURCE WITH A SHARP TOOL. STAKE SHALL BE FREE FROM DISEASE OR EXCESS DEAD TWIGS, 2.5 TO 4 FEET IN LENGTH WITH A BASAL END 0.5 TO 1.5 INCH IN DIAMETER. PRIOR TO INSTALLATION BASAL END SHALL BE CUT AT A 45 DEGREE ANGLE AND THE TOP END SHALL BE CUT FLAT WITHOUT CRACKS. 3. LIVE STAKES SHALL BE INSTALLED BY GENTLY TAMPING INTO THE SOIL LEAVING 20% EXPOSED. STAKES SHALL BE PLACED IN A RANDOM PATTERN AT A RATE OF 1 LIVE STAKE PER SQUARE YARD ALONG BANKS FOR 8 FEET WIDTH (APPROXIMATELY 3 ROWS). 4. LIVE STAKES SHALL BE INSTALLED WHEN THEY ARE DORMANT, WHICH TYPICALLY OCCURS BETWEEN OCTOBER 31 AND MARCH 31. 5. SEE PLANTING SCHEDULE. -OIR MATTING FROM TOE OF SLOPE BA�1` II I Tr 2 FT. BEYOND 3. INSERT PLANTING BAR 21N. TOWARD PLANTER FROM SEEDLING. 6. LEAVE COMPACTION HOLE OPEN WATER THOROUGHLY. SECTION A -A BANKFULL w/ 2" GALVANIZED ROOFING NAIL AT THE TOP TO HOLD MATTING CE:t-T1t-NK1 D D NOTES: 1. ALL MATERIALS ARE TO BE APPROVED BY ENGINEER OR ENGINEER'S ONSITE CONSTRUCTION MANAGER. 2. BEFORE INSTALLING COIR MATTING, TILL UPPER 3'4' OF SOIL TO HELP VEGETATION TO ESTABLISH. RAKE SOIL LEVEL AND ADD SEED AND MULCH BEFORE INSTALLING COIR FIBER MATTING. 3. MATTING SHALL TERMINATE AND BE BURIED AT THE EDGE OF CHANNEL SUBSTRATE. MATTING SHALL NOT EXTEND BELOW LOW -FLOW STAGE IN TWO-STAGE RIFFLE. PLANTING BAG: DURING PLANTING, SEEDLINGS SHALL BE KEPT IN A MOIST CANVAS BAG OR SIMILAR CONTAINER TO PREVENT THE ROOT SYSTEMS FROM DRYING. KBC PLANTING BAR: PLANTING BAR SHALL HAVE A BLADE WITH A TRIANGULAR CROSS SECTION, AND SHALL BE 121N. LONG, 41N. WIDE AND 11N. THICK AT CENTER. ROOT PRUNING: ALL SEEDLINGS SHALL BE ROOT PRUNED, IF NECESSARY, SO THAT NO ROOTS EXTEND MORE THAN 10 INCHES (101N.) BELOW THE ROOT COLLAR. NOTES: 1. TREE REFORESTATION SHALL BE PLANTED CTO 10' ON CENTER, RANDOM SPACING, AVERAGING 8' ON CENTER, APPROXIMATELY 680 PLANTS PER ACRE. 2. OTHER PLANTING METHOD CAN BE USED WITH THE PERMISSION OF THE PLANTING SUPERVISOR. 3. ALL MATERIALS ARE TO BE APPROVED BY ENGINEER OR ENGINEER'S ONSITE CONSTRUCTION MANAGER. V0 I I~ U 4 m) 7 i3 0 0 , o EQ 3 a ■ Cn r � C) S (TYP) C) ■ °� p 0- �>- 2Q1-0 -0 D CO 11 ■ ■ ■ ■ ■ ■ 6" MIN.J HORIZONTAL OVERLAP MATTING STAKING VIEW 2 MATTING, TYPICAL 65 NOT TO SCALE 1. INSERT PLANTING BAR AS SHOWN 2. REMOVE PLANTING BAR AND PLACE AND PULL HANDLE TOWARD SEEDLING AT CORRECT DEPTH. PLANTER. 4. PULL HANDLE OF BAR TOWARD PLANTER, FIRMING SOIL AT BOTTOM. 5. PUSH HANDLE FORWARD FIRMING SOIL AT TOP. DIBBLE PLANTING METHOD USING THE KBC PLANTING BAR (FOR FLOODPLAIN BUFFER PLANTING AND UPLAND BUFFER PLANTING) 3 PLANTING LINEAR BAREROOT 65 NOT TO SCALE 2' LONG 1"x 2" WOOD STAKES w/ 2" GALVANIZED ROOFING NAIL AT THE TOP TO HOLD MATTING I� BKF ELEVATION PROPOSED GROUND NOTES: 1. LIVE STAKES SHALL BE INSTALLED WHERE INDICATED ON THE DRAWINGS AND DETAILS. 2. LIVE STAKES SHALL BE CUT FROM AN APPROVED SOURCE WITH A SHARP TOOL. STAKE SHALL BE FREE FROM DISEASE OR EXCESS DEAD TWIGS, 2.5 TO 4 FEET IN LENGTH WITH A BASAL END 0.5 TO 1.5 INCH IN DIAMETER. PRIOR TO INSTALLATION BASAL END SHALL BE CUT AT A 45 DEGREE ANGLE AND THE TOP END SHALL BE CUT FLAT WITHOUT CRACKS. 3. LIVE STAKES SHALL BE INSTALLED BY GENTLY TAMPING INTO THE SOIL LEAVING 20% EXPOSED. STAKES SHALL BE PLACED IN A RANDOM PATTERN AT A RATE OF 1 LIVE STAKE PER SQUARE YARD ALONG BANKS FOR 8 FEET WIDTH (APPROXIMATELY 3 ROWS). 4. LIVE STAKES SHALL BE INSTALLED WHEN THEY ARE DORMANT, WHICH TYPICALLY OCCURS BETWEEN OCTOBER 31 AND MARCH 31. 5. SEE PLANTING SCHEDULE. -OIR MATTING FROM TOE OF SLOPE BA�1` II I Tr 2 FT. BEYOND 3. INSERT PLANTING BAR 21N. TOWARD PLANTER FROM SEEDLING. 6. LEAVE COMPACTION HOLE OPEN WATER THOROUGHLY. SECTION A -A BANKFULL w/ 2" GALVANIZED ROOFING NAIL AT THE TOP TO HOLD MATTING CE:t-T1t-NK1 D D NOTES: 1. ALL MATERIALS ARE TO BE APPROVED BY ENGINEER OR ENGINEER'S ONSITE CONSTRUCTION MANAGER. 2. BEFORE INSTALLING COIR MATTING, TILL UPPER 3'4' OF SOIL TO HELP VEGETATION TO ESTABLISH. RAKE SOIL LEVEL AND ADD SEED AND MULCH BEFORE INSTALLING COIR FIBER MATTING. 3. MATTING SHALL TERMINATE AND BE BURIED AT THE EDGE OF CHANNEL SUBSTRATE. MATTING SHALL NOT EXTEND BELOW LOW -FLOW STAGE IN TWO-STAGE RIFFLE. PLANTING BAG: DURING PLANTING, SEEDLINGS SHALL BE KEPT IN A MOIST CANVAS BAG OR SIMILAR CONTAINER TO PREVENT THE ROOT SYSTEMS FROM DRYING. KBC PLANTING BAR: PLANTING BAR SHALL HAVE A BLADE WITH A TRIANGULAR CROSS SECTION, AND SHALL BE 121N. LONG, 41N. WIDE AND 11N. THICK AT CENTER. ROOT PRUNING: ALL SEEDLINGS SHALL BE ROOT PRUNED, IF NECESSARY, SO THAT NO ROOTS EXTEND MORE THAN 10 INCHES (101N.) BELOW THE ROOT COLLAR. NOTES: 1. TREE REFORESTATION SHALL BE PLANTED CTO 10' ON CENTER, RANDOM SPACING, AVERAGING 8' ON CENTER, APPROXIMATELY 680 PLANTS PER ACRE. 2. OTHER PLANTING METHOD CAN BE USED WITH THE PERMISSION OF THE PLANTING SUPERVISOR. 3. ALL MATERIALS ARE TO BE APPROVED BY ENGINEER OR ENGINEER'S ONSITE CONSTRUCTION MANAGER. V0 U 4 m) 7 i3 0 0 , o EQ 3 0 0 N 0 o� E � 4 m) 0 0 , o EQ 3 0 0 N O c U U r � C) Q2 C) °� p 0- r 2Q1-0 -0 D CO om v2 � �- a5 N IQ C 0 o � a a 3 a o �: V) N C '0 o o -11 � � a Im C) C U To 0 � o " o >o -0a) 0 U ~ o z a) R> o� a) C o a a Q p a a c T a c 3 a o o 0� C4 3 2 U U c�1 U 3 o 0 0 0 0 r r IQ I¢ Im Im O N N Ln a� U N cn N 0 E i O cn O U 0) U � N � O � U U Permit -Seal EO Project Number: 175613085 File Name: 13085C-002-VEG.dwg Dwn. Chkd. Dsgn. YY.MM.DD Drawing No. # Revision Sheet O 65 of 73 Goose Creek Watershed On -Site Wastewater System (Septic System) Failure Rate Analysis By Jeremy Michael A project submitted to the Graduate Faculty of North Carolina State University In partial fulfillment of the requirements for the degree of Masters of Environmental Assessment Raleigh, North Carolina 2012 Approved by advisory committee Advisory Chair: Linda Taylor ABSTRACT Michael, Jeremy A. Goose Creek Watershed On -Site Wastewater System (Septic System) Failure Rate Analysis. (Under the direction of Linda Taylor). The Goose Creek Watershed located in Mecklenburg County, North Carolina is home to the federally endangered Carolina heelsplitter mussel which is sensitive to many pollutants commonly found in municipal and industrial wastewater releases. On-site wastewater systems were evaluated within the Goose Creek Watershed from April 2009 through April 2011 to determine if any failing on-site wastewater systems could have had a significant impact on high fecal coliform counts found in the tributaries. This project considered how the following criteria could contribute to on-site wastewater system performance: system design, age of system, seasonal impacts, operation and maintenance, and siting location. On-site wastewater failures were found at 12 out of 1,422 sites inspected, with a failure rate of 0.84%. This failure rate is considerably lower than other failure rate studies conducted in North Carolina and abroad. Only three of the twelve failures were located within 400ft of any surface water indicating a minimal impact on-site wastewater failures may have contributed to the high fecal coliform counts throughout the watershed. Age and excessive water usage from leaks or too many people living in the residence was a major contributing factor to more than half of the failures observed. On-site wastewater systems that were sited based on the soil type, operated per design, and maintained routinely had lower impacts on failures. This may be attributed to Mecklenburg County having a licensed soil scientist on staff, along with conducting routine public management entity (PME) inspections. There was a higher failure rate observed in the wet season as opposed to the dry season. Further investigation is needed to determine other potential sources of fecal coliform found in the tributaries throughout the watershed. BIOGRAPHY Jeremy Michael attended Western Carolina University and earned a B.S. in Environmental Health in 2003. During the summer of 2002 he interned as a Jr. Commissioned Officer with the United States Public Health Service working with the Indian Health Services in Minot, ND. He started his professional career working as a Registered Environmental Health Specialist for Lincoln County Environmental Health and as a consultant for S&ME. Mr. Michael has worked for Mecklenburg County since 2006 and is a Supervisor in the Groundwater and Wastewater Services section. His area of interest has been in evaluating soils along with permitting and designing on-site wastewater systems throughout many counties in the Piedmont and Mountains of NC. ACKNOWLEDGEMENTS I would like to express sincere thanks to all involved in this project including staff from the Groundwater & Wastewater Services and Water Quality Departments of Mecklenburg County. I would also like to thank Mr. Jeff Price for his assistance with statistical analysis of data collected for this project. To my advisor Ms. Linda Taylor who was very helpful at answering my questions and guiding me though this graduate program. Lastly, I would like to thank my family especially my wife and daughter for your endless support during graduate school. TABLE OF CONTENTS LISTOF FIGURES...........................................................................................v LIST OF APPENDICES....................................................................................vi INTRODUCTION............................................................................................. l METHODS AND MATERIALS............................................................................3 StudyArea.............................................................................................3 StudyDesign..........................................................................................4 Preparations for Field Survey.......................................................................7 FailureDefinition.....................................................................................8 DataCollection.......................................................................................9 RESULTS AND DISCUSSION.............................................................................9 SystemAge Impacts................................................................................10 Siting Impacts/ System Use Practices............................................................13 System Design/ Maintenance Impacts............................................................15 Wet vs. Dry Season Failures.......................................................................17 Surface Water Quality Impact.....................................................................18 SUMMARY AND CONCLUSION.......................................................................20 REFERENCES CITED......................................................................................23 iv LIST OF FIGURES Figure 1. Cumulative on-site wastewater system failure rate percentage vs. age of the system.......................................................................................11 Figure 2. Individual on-site wastewater system failure rate percentage vs. age of the system.......................................................................................12 Figure 3. Causes of on-site wastewater system failures in the Goose Creek Watershed..... 14 Figure 4. On-site system types in the Goose Creek Watershed.................................16 Figure 5. Box and whisker plot on before and after fecal counts in the Goose Creek tributary......................................................................................1 9 VA LIST OF APPENDICES Appendix 1. Map and location of on-site wastewater system inspections in the Goose Creek Watershed....................................................................................26 Appendix 2. On-site wastewater system inspection form used in the Goose Creek Watershed...................................................................................27 Appendix 3. Information pamphlet used in the Goose Creek Watershed ..........................28 Appendix 4. Goose Creek Watershed On-site wastewater system failure chart..................29 vi INTRODUCTION On-site wastewater systems (also called septic systems) have been used effectively in treating sewage for many years. Approximately 21 % of American homes are served by on-site wastewater systems and 95% of these are septic systems (USCDC, 2009). Over 50% of households across North Carolina use onsite wastewater systems with new systems being installed at a rate of 40,000 per year (Hoover and Konsler, 2004). However, there have not been many studies conducted on the lifespan, failure rates, and survival ability of on-site wastewater systems across the State. Other studies that have been conducted within North Carolina by standard practice have taken two different approaches in carrying out an on-site wastewater system failure analysis. One is drawing random on-site wastewater system permits from the local health department and studying a broad area, while the other is to zero in on a particular area and conduct a blanket or enforcement survey (Hoover, 2011). Both of these methods, while different, offer valuable data to be used in the future of on-site wastewater system designs, technology, and maintenance. On-site wastewater system failures are important to remediate due to the potential health concerns to humans, wildlife, and the environment. Sewage that has surfaced to the ground can contain many harmful bacteria and pathogens that could cause disease such as dysentery, hepatitis, typhoid fever, and acute gastrointestinal illness if exposure to humans occurs (Mass DEP, n.d.). Nutrients in untreated sewage, particularly nitrates, nitrites, and phosphorous if in excess can cause nutrient overload also known as eutrophication to occur in surface waters. The Goose Creek Watershed is comprised of 42 square miles in Union and Mecklenburg counties and is also home to the Carolina heelsplitter mussel which was added to the federal endangered species list in 1993. Due to elevated bacteria levels, the N.C. Department of Environment and Natural Resources (DENR) indentified Goose Creek as being impaired. Management rules were developed and approved by DENR to protect the water quality and habitat needed to recover and sustain the Carolina heelsplitter mussel. In order to comply with the state rules, the Town of Mint Hill and Mecklenburg County established a Water Quality Recovery Plan (WQRP) with the goal to identify and remove sources of fecal coliform in the watershed. The WQRP specified that fecal coliforms shall not exceed a geometric mean of 200/100 ml (membrane filter count) based upon at least five consecutive samples examined during any 30 -day period, nor exceed 400/100 ml in more than 20 percent of the samples examined during such period (Mecklenburg County Storm Water Services, 2009). Samples collected in different locations throughout the watershed were found to have fecal coliform results higher than what the WQRP specified. Results from one specific sampling point had a median of 960 CFU/ 100ml and a mean of 1,162 CFU/ 100ml out of 21 fecal coliform samples collected. Mecklenburg County Storm Water Services conducted field surveys, stream walks, and identified all storm water outfalls, in addition to sampling, and these efforts have not been successful in identifying sources of fecal coliform. During stream walks, environmental specialist would look for leaking sewer laterals that crossed creeks along with overflowing sewer access risers that were adjacent to creeks. On-site wastewater systems were the most likely source of fecal coliform contamination that had not been evaluated. Approximately 54% of the residences located within the Goose Creek Watershed are served by on-site wastewater systems. The purpose of this study was to identify all failing on-site wastewater systems in the Goose Creek Watershed within Mecklenburg County and determine if the onsite wastewater systems are a significant contributor to high fecal coliform contamination in the tributaries. 2 Investigating all on-site wastewater systems within a specific location provided the opportunity to identify failing systems, repair the systems, and evaluate on-site wastewater system performance under a variety of real-life operating conditions. In addition, the performance and longevity of different on-site wastewater system types (i.e. conventional, approved, low pressure pump panel block systems, drip irrigation etc.) could be evaluated. On- site wastewater systems that are identified as failing would be further investigated as to the reason why the failure occurred. The results from this study will provide Groundwater and Wastewater Services of Mecklenburg County with a snap shot of how well on-site wastewater systems are performing within the county and to determine if they have a significant impact on surface water quality of Goose Creek. METHODS AND MATERIALS Study Area Mecklenburg County is located in the southwest portion of the Piedmont area of North Carolina. The Goose Creek Watershed includes the Goose Creek and Duck Creek subbasins both located in the southeast portion of Mecklenburg County and is within the city limits of Mint Hill (Appendix 1). Although the majority of the Goose Creek Watershed is in Union County, the on- site wastewater system survey only included the portion in Mecklenburg County where the headwaters for the watershed originate. The estimated acres and percentage of the Goose Creek subbasin located in Mint Hill is 4,938 acres (18.1%) and 2,354 acres (8.6%) of the Duck Creek subbasin which together is a total of 7,292 acres (26.7%) of the Goose Creek watershed located in Mecklenburg County that was surveyed (NCWRC and NCHP, 2005). Cecil soils occur most often in Mecklenburg County and in the Goose Creek Watershed on gently sloping to strongly sloping topography, and make up about 41percent of the counties 3 soils. Cecil soils are well drained soils that have predominantly clayey subsoil and are formed in residuum from acid igneous and metamorphic rock. Soils in the Goose Creek Watershed were predominantly mapped as CeD2- Cecil sandy loam, 8 to 15 percent slopes, eroded, and CeB2- Cecil sandy clay loam, 2 to 8 percent slopes, eroded (McCachren, 1977). Typically on an auger boring 48 inches deep, the surface layer is sandy clay loam to about 6 inches with the majority of the subsoil consisting of clay and clay loam texture towards the bottom of the boring. According to the NC Regulations for Sewage Treatment and Disposal systems these soils are considered to be Group IV- clayey texture soils, and are classified as provisionally suitable with respect to soil texture (NCDENR, 2000). Study Design The study area for this project includes all parcels that are served by on-site wastewater systems within the Goose Creek Watershed in Mecklenburg County. All parcels connected to municipal sewer were not included in this study although existing sewer laterals could be a potential source of fecal coliform contamination. Goose Creek Watershed is subdivided into 14 separate catchment basins and the study was carried out one catchment basin at a time. Factors used to determine the order (priority) that on-site wastewater systems were inspected were as follows: 1. Catchment basin (14 total), 2. Proximity to stream (200 ft. buffer), 3. Age of on-site wastewater system (estimated from CAMA development data). Catchment basins were prioritized from 1 to 14 by the Water Quality (WQ) program and provided to Groundwater & Wastewater Services (GWS). Groundwater and Wastewater Services then develop an inspection schedule for each catchment based on the following matrix: 4 Tier Proximity to stream 1 <= 200 ft. 2 <= 200 ft. 3 > 200 ft. 4 > 200 ft. 5 > 200 ft. Septic System Age (yrs.) 29+ (Pre -1980) 0-28 (1981-2009) 29+ (Pre -1980) 14-28 (1980-1995) 0-13 (1996-2009) There were a total of 2,740 parcels in all 14 catchment basins within the Goose Creek Watershed. In Mecklenburg County forty three percent (1,187 parcels) of the total number of parcels were vacant or served by municipal sewer. This was determined by looking at sewer lateral maps, knowledge of known subdivisions on municipal sewer, and aerial photography. Because the catchment basins parcels were computer generated there were 73 parcels that were picked twice on two separate catchment basins where they may have fell on the line separating the catchments. In these instances these parcels were accounted for and only evaluated one time. Therefore there were 1,480 on-site wastewater systems within the Goose Creek Watershed to investigate. Unlike some previous studies on failure rate analysis in North Carolina, this study was conducted over a longer period of time, beginning in April 2009 and completing in April, 2011. Most failure rate analysis assessments are performed during a short amount of time or days to minimize potential impacts (and biases in the results) due to variation in soil moisture status and/or precipitation for different parts of the study sample (Hoover, Lynn et al. 2005). Generally, because groundwater recharge is more substantial during the wet season (spring), failure rates are more likely to occur. However, an important component of this study was to eliminate any and all sources of fecal coliform that may be coming from parcels served by on- site wastewater systems. Although failure rates may be greater during one season over another, 5 there is beneficial information that can be obtained from inspecting on-site wastewater systems over all seasons of the year and with varying hydraulic conditions. After all, on-site wastewater systems are in use year round and groundwater recharge is only one variable among many that may contribute to on-site wastewater system failures. Methodologies used in conducting the study in the Goose Creek Watershed included a notification, inspection, and education carried out by an inspection form and an educational information pamphlet (see appendix 2 and 3). In addition, if on-site wastewater systems were observed failing at the time of inspection, a home owner interview form was used to diagnose the problem. All participants in the study were notified through a letter that was mailed out before a site visit was made to inspect the on-site wastewater system. Information detailing the purpose of the on-site wastewater system inspections was included in the letter, but it did not give a specific time when the inspections would be conducted. Others studies avoid sending out letters prior to an inspection to prohibit home owners from getting illegal (non- permitted) repairs installed. Some homeowners did have their septic tanks pumped prior to the inspection, but this rarely fixes a failing septic system and is not considered a repair. In addition, there were no illegal repairs reported or found on any of the parcels inspected during the course of this study. The letter was sent out prior to an inspection to notify the homeowner that the inspection would be taking place and give them an opportunity to respond if they refused the inspection or had additional information. If no response came back and the homeowner was not present at the time of inspection, the inspector could legally walk around the premises and evaluate the on-site wastewater system. In addition, this was an opportunity for homeowners to call the office and set up a time for an inspection, allowing inspectors to gain access to properties that had locked 11 gates and dogs. However, if there was a fence or gate that was closed and the on-site wastewater system was not visible at the time of the inspection, than the site was classified as inaccessible. Any site where the homeowner refused to allow an inspection was also deemed inaccessible and these sites were turned over to the Mecklenburg County Water Quality Department for further evaluation. Most cases of inaccessibility were from locked gates or tall fences around the septic field and not homeowner refusal. Of the 1,480 on-site wastewater systems in the watershed, only 58 (3.92%) were inaccessible. Moreover, there were only 419 sites out of the 1,480 where the homeowner was present for the inspection thus reiterating the need for the letter to be mailed out so inspectors could legally walk around the premises to conduct the inspection. Preparations for the Field Survey There were a total of six inspectors within Groundwater and Wastewater Services to conduct the study. All inspectors were Registered Environmental Health Specialist with the State of North Carolina and authorized in on-site wastewater. Inspections were spread out among each inspector with the number of inspections varying depending on the catchment. When the inspections were sent out to the inspectors, there was a deadline date to have them completed. This deadline varied depending on the number of inspections to complete but was usually quarterly. Each inspector conducted their inspections at their own pace working in between their regular assigned job duties. Prior to going out to each lot, the inspector would search the county database to see if there was an existing permit on the property showing where the septic system was located and to identify what type of aggregate was used in the nitrification field. 7 The inspectors were equipped with an information pamphlet, and a carbon copy inspection form. Inspectors would knock on the door and if the homeowner was present, they would announce themselves and educate them on why their septic system was being inspected along with handing the homeowner an information pamphlet on the Goose Creek Watershed and the Carolina heelsplitter (appendix 3). If the homeowner consented, the inspector would probe the nitrification field and determine the type of onsite wastewater system. For any innovative or accepted system, each inspector had a permit on hand to confirm the system type. The age of the system was determined by the operation permit date on file with the Mecklenburg County Health Department. The age for systems where no operation permit was found was determined by the date the house was built found through Mecklenburg County online geographical POLARIS system. Most of the older systems where a permit could not be found were determined to be gravel systems. Observations were made to determine if there were trees in the nitrification field area, irrigation systems, or wells on the property. All information was recorded on the inspections survey form (appendix 2). Failure Definition A failure described in the Laws and Rules For Sewage Treatment, And Disposal Systems (1900 Rules) is (1) a discharge of sewage or effluent to the surface of the ground, the surface waters, or directly into groundwater at any time; or (2) a back-up of sewage or effluent into the facility, building drains, collection system, or freeboard volume of the tanks; or (3) a free liquid surface within three inches of finished grade over the nitrification trench for two or more observations made not less than 24 hours apart. Observations shall be made greater than 24 hours after a rainfall event (NCDENR, 2000). For the purpose of this study the failure definition was limited to (1) a discharge of sewage to the surface of the grounds or (2) a straight pipe to the land surface, or (3) when a nitrification line was probed the sewage surfaced to the ground. If one of these observations were made at the time of the inspection, the system was documented as failing and a notice of violation was mailed to the homeowner. Data Collection For every on-site wastewater system inspection performed, a work order was created in City Works Server. City Works is a computer program used by Mecklenburg County that can be used to geospatially register on-site wastewater systems and wells. If a site had an on-site wastewater system or well on the property, the inspector would register the on-site wastewater system or well in the database and a separate point would show up on a map indicating there was an on-site wastewater system or well. For every on-site wastewater system registered, a work order was created and information was entered into the computer program summarizing the findings of the survey. RESULTS AND DISCUSSION On-site wastewater failures were observed at 12 out of 1,422 sites inspected, with a failure rate of 0.84% over the course of the survey. Hydraulic field assessments of conventional and alternative technologies have been conducted over the last 25 years that identified system failure rates ranging from less than 5% to almost 50% (Hoover, 2011). This failure rate percentage was lower than other low end failure rates found in other studies (Hoover et al. 2007) which found a 9.7% failure rate in Wake County, and less than 5% failure rate in a multi county health district in eastern North Carolina (Lindbo et al, 1998). 01 The study conducted in Wake County, North Carolina was different in nature taking random on-site wastewater systems throughout Wake County and inspecting all on-site wastewater systems during the wet season when hydraulic failures occur more often (Hoover et al. 2007). The study that took place in the multi county health district in North Carolina (Lindbo et at, 1998) was a separate assessment 5 years after a management entity was put into place from a previous (Hoover et al. 1993) study that found a 12 to 16% failure rate in conventional aggregate -laden and sand lined trench systems less than 5 years old (Hoover, 2011). During the Goose Creek survey there were a total of 12 notices of violations issued. Out of the 12 failures, there were only three considered to be high risk of fecal contamination to tributaries in the Goose Creek Watershed. The three high risk sites occurred within a 400ft buffer around creeks or surface waters (see appendix 1). Each on-site wastewater system that was failing was further investigated as to the probable cause of the failure (see appendix 2). Because the number of failing septic systems was so low, statistical analysis could not properly be done however trends and observations could be made. System Age Impacts The average age of the on-site wastewater systems inspected in the Goose Creek Watershed was 27.4 years old. The average age of the failing on-site wastewater systems in the Goose Creek Watershed was 34 years old. There was not an operation permit on file for one on- site wastewater system that according to POLARIS the house was constructed100 years ago. This number was thrown out because 100 years ago the residence more than likely used an outhouse or privy and a record of the on-site wastewater installation could not be determined. There was a significant correlation between increased age of the on-site wastewater system and 10 percentage of on-site wastewater failure in the Goose Creek Watershed as opposed to a (Hoover et al. 2007) Wake County study that found a 10% failure rate for newer systems matched about a 10% failure rate of older systems. All but one septic system failure found during this survey was older than 20 years, with seven of the failures occurring between the ages of 30 and 38 years old (see figure 1 and 2). Cumulative Septic System Failure Rate Figure 1. Cumulative on-site wastewater system failure rate percentage vs. age of the system 11 0.16 0.14 0.12 0.10 Q) 3 m 0.08 U. 0.06 0.04 0.02 0.00 Septic System % Failure Rate c-INM�lf1101�00010�--INM� V1101�00010�--INM�I.!)lflI�00010�--INM� V11D1�00410�--INM�L.()101�00010�--INM�Lf1 e--I�--I�--I�--I�--I�--Ic-I�--I�--I�--INNNNNNNNNNMMMMMMMMMM����������tf1 V1 V1 V1 V1 V1 System Age Figure 2. Individual on-site wastewater system failure rate percentage vs. age of the system Although there were more on-site wastewater failures found with an age greater than 20 years, it must be noted that it does not necessarily indicate the failures were a direct result of age. Water usage among other variables can contribute to an on-site wastewater failing regardless of age. It is reasonable to conclude in this study, that if on-site wastewater systems are designed and used properly they can be expected to last 30 years before they start to show age related failures. 12 Siting Impacts/ System Use Practices Trees were located within the nitrification field on 398 (27.99%) sites, and irrigation was installed within the nitrification field on 96 (6.75%) sites. Tree roots or biomat problems and excessive watering over the nitrification field can contribute to failures of on-site wastewater systems. Trees were observed in the nitrification field on 5 out of the 12 failures found. After a more thorough investigation was conducted only 2 out of the 5 on-site wastewater system failures found with trees in the nitrification field were caused by tree roots and/or biomat problems. Biomat is a bacteria layer that forms along the bottom and sidewalls of a drainage trench. As the on-site wastewater system ages and the biomat grow thicker it can reduce infiltration rates to a point where ponding occurs. Two of the failures occurred due to age/biomat clogging up the nitrification field. None of the on-site wastewater systems found failing had irrigation systems over the nitrification field. A further study would be required to determine if irrigation systems located within nitrification fields contribute to failure rates of on- site wastewater systems. There was a strong correlation with increased failure and excessive water usage within the majority of on-site wastewater systems found failing in this study. Half of the on-site wastewater system failures that occurred were caused by excessive water usage. Out of the six excessive water usage sites, three sites had more people living in the residence than the on-site wastewater system was designed to support, and the other three had leaking toilets that were continuously running. In addition, there were two failures that occurred because the on-site wastewater system was damaged or destroyed. One on-site wastewater system found failing had a garage built over the nitrification field and the other site had a wash line that was straight piped to the surface of the ground (see figure 3). 13 7 6 S 4 3 2 1 0 Causes of Septic Failures ■1■ ■ Number of Septic Failures Figure 3. Causes of on-site wastewater system failures in the Goose Creek Watershed Soils were evaluated on failures that needed a repair permit to add additional nitrification fields. There were no soil suitability issues on any of the sites that were failing. All sites that needed a repair were given a long term acceptance rate (LTAR) of 0.3 GPD/FT 2. A 0.3 LTAR is a common upper limit loading rate given to Cecil type soils found in the Goose Creek Watershed. However, in addition to soil properties, landscape position is taken into consideration when assigning a LTAR. Similar to the (Hoover et al. 2007) study conducted in Wake County in 2003, soil suitability not being a main contributing factor in on-site wastewater system failures in this survey is attributed to the expertise of a licensed soil scientist evaluating all soils within Mecklenburg County. Previous studies in North Carolina (Hoover and Amoozegar 1989; Hoover et al. 1993) and in Pennsylvania (Hoover et al. 1981) have found failure rates of 20% and greater where soil suitability did not match well with that recorded on the system permit by the environmental specialist. As a result, septic systems were installed in 14 Jya�e �°lea c�+�e Qat ■1■ ■ Number of Septic Failures Figure 3. Causes of on-site wastewater system failures in the Goose Creek Watershed Soils were evaluated on failures that needed a repair permit to add additional nitrification fields. There were no soil suitability issues on any of the sites that were failing. All sites that needed a repair were given a long term acceptance rate (LTAR) of 0.3 GPD/FT 2. A 0.3 LTAR is a common upper limit loading rate given to Cecil type soils found in the Goose Creek Watershed. However, in addition to soil properties, landscape position is taken into consideration when assigning a LTAR. Similar to the (Hoover et al. 2007) study conducted in Wake County in 2003, soil suitability not being a main contributing factor in on-site wastewater system failures in this survey is attributed to the expertise of a licensed soil scientist evaluating all soils within Mecklenburg County. Previous studies in North Carolina (Hoover and Amoozegar 1989; Hoover et al. 1993) and in Pennsylvania (Hoover et al. 1981) have found failure rates of 20% and greater where soil suitability did not match well with that recorded on the system permit by the environmental specialist. As a result, septic systems were installed in 14 soil conditions that did not have proper loading rates issued by environmental specialist (Hoover et al. 2007). Registered environmental health specialist do have the ability to evaluate soils in North Carolina to permit on-site wastewater systems, however the only soils training is obtained from a three week centralized intern training course in Raleigh and on the job experience. Mecklenburg County has supported having a licensed soil scientist on staff and it is the author's opinion that this level of expertise has prevented on-site wastewater failures from occurring due to systems being installed in properly characterized soils. System Design/Maintenance Impacts Conventional gravel on-site wastewater systems were most prevalent type of system used in the Goose Creek Watershed with 1,046 (72%) inspected (Figure 4). Most of these were gravel bed systems meaning the trench was greater than 3ft in width. Although all failures found were conventional gravel systems, the failures were not attributed to system type alone but rater excessive water usage and age related issues. There was no indication that system type had any impact on the failure rate. Other studies have shown that lack of professional maintenance of low-pressure pipe systems (LPP) can increase failure rates (NCDENR, 2011). In addition to there being a low percentage of LPP and pump systems in this watershed, the overall low failure rate could be contributed to the Public Management Entity (PME) program that is implemented within Mecklenburg County. 15 Septic System Types in The Goose Creek Watershed Gravity Conventional ■ Gravity 25% Reduction Pump 25% Reduction Pump Conventional ■ LPP Panel I Gavity Panel 5% 3% <1% Figure 4. On-site wastewater system types in the Goose Creek Watershed. The rules that govern onsite wastewater systems in North Carolina require that the Health Department conduct PME inspections for LPP systems once every three years and single pump systems once every five years. In reality very few counties across North Carolina conduct these inspections due to limited staff and resources. There are benefits to inspecting systems with mechanical features by identifying systems that are failing or may fail without maintenance, and routinely educating the owners of these systems with information and a written report on their on-site wastewater system inspection. There was no indication that on-site wastewater system failures occurred more often based on the system type alone. Although there were a lower percentage of pump and LPP systems inspected in the Goose Creek Watershed, it is the author's opinion that routine PME inspections, identifying maintenance issues, educating homeowners, along with certified operator reviews of these systems contributed to a 0% failure rate on these types of systems during the course of this study. 16 Wet vs. Dry Season failures The wet season in the Piedmont of North Carolina occurs in the springtime. Typically there is more rainfall during the summer months but with higher temperatures along with evaporation and transpiration, the subsoil is usually dryer during the summer than in the winter and spring. Most short-term on-site wastewater failure rate studies are conducted in the wet season when the hydraulic performance is most limited for on-site wastewater system and hydraulic failure is most likely to occur. (NCDENR, 2011). As expected, the wet season failure rate was higher than the dry season failure rate. During the spring time antecedent soil moisture conditions are the wettest, rainfall is plentiful and groundwater recharge is substantial (Hoover et al. 2007). Generally in November and December, when most of the vegetation is dormant and the evaporative capacity of the air is low, the groundwater levels begin to rise (LeGrand and Mundorff, 1952). Out of the 12 system failures found, 7 were during the spring months of March through May. The other 5 system failures were found during the winter months of November through February. There were no on- site wastewater failures found or reported over the summer months during the course of this study. High dry season failure rates have been reported in another study (Hoover et al, 198 1) which found cumulative failure rates of 40-50% in Pennsylvania for undersized sand mound systems that were less than 3 years old (NCDENR, 2011). In future studies, using monitoring well groundwater level and drought data from the USGS and NC Division of Water Resources could be useful to determine if seasonally high groundwater levels correlate to an increase in on- site wastewater failures. 17 As mentioned previously, half of the on-site wastewater system failures found in this study were due to excessive water usage. It is unknown if these systems were failing in the summer months prior to the inspections that took place over the winter and spring months, or if the wetter soil conditions during this time contributed to the failure of these systems. Further study would be required to determine if excessive water usage failure rates fluctuated with wet vs. dry seasons. Surface Water Quality Impact Aside from the on-site wastewater systems failure rate analysis, fecal coliform samples were analyzed in several tributaries within the Goose Creek Watershed to determine if failing on- site wastewater systems contributed to higher fecal coliform counts in the creeks. There were only three failing on-site wastewater systems found within 400ft of any stream within the boundaries of this study. One specific area with a high number of on-site wastewater systems within 200ft of a stream was further analyzed for fecal coliform counts after a on-site wastewater system was found failing within 200ft of the creek. Samples had been taken before the failing on-site wastewater system was found and after the on-site wastewater system was repaired. A non -parametric statistical box and whisker plot analysis was used to determine if there was a statistical significance in fecal coliform counts (CFU/100ml) before and after the on-site wastewater system was repaired (See figure 5). The P value was .02 and anything below .05 is considered to be statistically significant. The .02 p value indicates a 98% confidence level that the data results were not based on error or random significance. However it must be noted that there were 21 fecal samples collected prior to the failing on-site wastewater system being repaired and only seven samples collected after the on-site wastewater system was repaired. 18 Ideally it would have been better to collect additional samples after the on-site wastewater system was repaired, but considering the downward trend in fecal counts along with the cost for sampling, additional samples were not collected. The Water Quality Department had a DNA analysis test performed on a bacteria sample collected to determine if it contained fecal coliform from a human or animal. The results of the test came back with a high percentage that the fecal coliform came from a human source. Further test were not done due to the high cost. Goose Creek Tributary95% Cl otc a utter Boxplot 95- Cl Mean Diamond + Outliers > 1.5 and < 3 IQR nl 28 Fecal Coliform n Rank sum Mean rank U 21 342.5 16.31 35.5 7 63.5 9.07 111.5 Fecal Before After n I Mn I 1st Quartile 21 140 626. 7 170 165. 480.0 110.0 to +m (normal approximation) 35.5 2.02 0.0218 (normal approximation, corrected for ties) Median 95% Cl I 3rd Quartile I Max IQR 960.0 640.0 to 1500.0 1500.0 39001 873.3 480.0 170.0 to 3600.0 631.7 3600 446.7 Figure 5. Box and whisker plot on before and after fecal counts in the Goose Creek tributary As illustrated in the diagram above, the median for fecal coliform counts before the on- site wastewater system was repaired was 960 CFU/100ml vs. 480 CFU/100ml after the on-site wastewater system was repaired. The U.S. EPA (1975) reported on studies performed in 19 Atlantic Beach and Surf City, North Carolina which showed high concentrations of fecal coliforms in surface waters that were in close proximity to dense housing developments served by on-site wastewater systems. It was observed that effluent from the on-site wastewater systems reached surface waters by using dye tracers and dye was detected in surface water within 4 to 60 hours respectively (Cardona, 1998). There is a vast difference in soil texture between the Coastal Plain and Piedmont soils. The soils in the Goose Creek Watershed are primarily of a clay texture as opposed to sand in the coastal region. Crane and Moore (1983) reported that under unsaturated flow conditions bacterial population could be reduced to up to 95% within the first 1-5 cm of soil and that clays were more effective than sand in bacterial removal. Other conditions such as saturated conditions, rainfall events, saturated conductivity, and low temperatures have been confirmed to enhance bacterial survival (Cardona, 1998). Dye packs were given to homeowners that lived along both sides of the Goose Creek Tributary that was sampled for fecal coliform. They were asked to flush the dye pack down their toilet and afterwards a representative from Water Quality would observe this section of Goose Creek. No dye was observed or reported in the creek, thus any coliform bacteria that may have entered Goose Creek directly from on-site wastewater systems may have come from surface runoff through rain events rather than subsurface movement of effluent. SUMMARY AND CONCLUSION A field study which took place from April 2009 through April 2011 in the Goose Creek Watershed of Mecklenburg County, North Carolina found on-site wastewater system hydraulic failures at 12 out of 1,422 sites inspected, with a failure rate of 0.84°/x. This failure rate was 20 considerably lower than other studies however the survey was in one specific area of the county as opposed to random sampling throughout the entire county. This low rate is consistent with reported failures within the same boundaries of the study a year after the study was conducted with only three on-site wastewater system failures reported from April, 2011 through March, 2012. The majority of the failures observed were due to age and excessive water usage from leaks or too many people living in the residence. Site maintenance through the PME program, education of homeowners, and certified operator contracts were considered a factor in the absence of on-site wastewater failures for pump, drip irrigation, and LPP systems inspected. Wet season hydraulic failures were considerably higher during the winter and spring months, with no failures found during the summer months. Siting had no significant impact on hydraulic failures in this study. Professional licensed soil scientists that have been on staff with Mecklenburg County for the past 30 years are attributed with a low on-site wastewater failure rate by siting and evaluating the soil in the areas that on-site wastewater systems are installed. In addition, there was no indication that system type had anything to do with failure rates. The majority of the on-site wastewater systems inspected were conventional bed systems that have proven to properly function with a very low failure rate and could be expected to last over 30 years if operated and maintained properly. Fecal coliform counts were statistically lower after one on-site wastewater system was repaired that was found failing within 200ft of Goose Creek. As for the entire watershed, there is little evidence that high fecal coliform counts over the desired TDML standards was attributed to failing septic systems within the watershed. Only three failing on-site wastewater systems were found within 400ft of tributaries throughout the watershed. Further research would be needed to 21 determine if on-site wastewater systems attributed to higher fecal coliform counts in surface waters by using DNA or other fingerprinting techniques to differentiate animal from human fecal coliform, and to trace samples collected from surface water back to samples taken from a failing on-site wastewater system. On-site wastewater system failures are not suspected as having a big influence for the decline of the Carolina heelsplitter mussel in the Goose Creek Watershed. The Carolina heelsplitter is more susceptible and sensitive to ammonia and prescription drugs found in surface waters from storm water runoff and sewage package plant overflows around Stevens Creek (Fridell, J (2008, January 20). Telephone interview). Urbanization along with construction activities that do not adequately control soil erosion contribute to excessive amounts of silt, pesticides, fertilizers, heavy metals, and other pollutants that suffocate and poison freshwater mussels (U.S. Fish and Wildlife Service, 2011). If any future studies are to be conducted within Mecklenburg County it would be beneficial to collect water samples from wells on properties that are also served by on-site wastewater systems to determine if there are any impacts on groundwater. In addition, it would be beneficial to compare the Goose Creek Watershed findings to a failure rate analysis using randomly selected on-site wastewater systems within the entire county. Overall the study was a success and gave Mecklenburg County an indication on how well on-site wastewater systems are performing within the study area, along with educating residences about on-site wastewater system use and maintenance. 22 REFERENCES CITED Cardona, M.E. (1998). Nutrient and Pathogen Contributions to Surface and Subsurface Waters From On-site Wastewater Systems -A Review. North Carolina State University Cooperative Extension Service. Hoover, M.T. (2011). "Failure rate, Lifespan and Survivability of On -Site Systems." North Carolina Soils and On -Site Wastewater Training Academy. Tech 201: Wastewater in the Environment, Col. Agr. and Life Sci., North Carolina Cooperative Extension, North Carolina State University, Raleigh, NC. Hoover, M.T. and Amoozegar, A. (1989). "Performance of alternative and conventional septic Tank systems." Proceedings of Sixth Northwest On -Site Wastewater Treatment Short Course. Univ. of Washington, Seattle, Washington., 173-203. Hoover, M.T., Evans, R.O., Hinson, T.H., Heath, R.C. (1993). Performance of sand -lined trench septic systems on wet, clayey soils in northeastern North Carolina. Soil Sci. Dept., Col. Agr. and Life Sci., North Carolina State University, Raleigh, NC. Hoover, M.T. and Konsler, T. (2004). Soil Facts: Septic systems and their maintenance, Publ. No. AG -439-13, North Carolina Cooperative Extension, Raleigh, NC. Hoover, M.T., Lynn, W.E., King, L.D., Nelson, L.A., Harris, S.M., Bristow, S.W., Angoli, P.M., Lowery, W. Daeke, K.G. (2007). On -Site Wastewater System (Septic System) Surface Hydraulic Failure Rates. Wake Co. ASCE JHE, Dept. review draft, Department of Environment Services, Raleigh, NC. 23 Hoover, M.T., Peterson, G.W., Fritton, D.T. (1981). "Utilization of Mound Systems for Sewage Disposal in Pennsylvania." Individual On -Site Wastewater Systems: Proc. 7th National NSF Conference. Edited by McCleland, N.I., Evans, T.L. National Sanitation Foundation, Ann Arbor, MI., King, L.D., Hoover, M.T., Polson, R.L., Everett, R.W. "Surface failure rates of chamber and traditional aggregate -laden trenches in Oregon." Small Flows Quarterly, Fall 2002, 3(4). Nat. Small Flows Clearinghouse, West Virginia University, Morgantown, WV., 27-36. LeGrand, H.E., Mundorff, M.J. (1952). "Geology & Ground Water Resources in the Charlotte Area, North Carolina. " U.S Geological Survey. Lynn, W.E., Hoover, M.T., King, L.D. Nelson, L.A., Harris, S.M., Bristow, S.W., Angoli, P.M., Lowery, W. Daeke, K.G. (2005) Wake County field performance and operation & Maintenance survey of systems installed 1982-2002. Wake Co. Department of Environmental Services, Raleigh, NC. Massachusetts Department of Environmental Protection (Mass DEP) (n.d.). How Failing Septic Systems Can Be Hazardous to Your Health. Retrieved January 28, 2012 from http://www.studygs.net/citation.htm. McCachren, C.M. (1977). Soil Survey of Mecklenburg County, North Carolina. USDA, Soil Conservation Service in cooperation with Mecklenburg County Board of Commissioners and North Carolina Agricultural Experiment Station. Washington, D.C. 24 Mecklenburg County Storm Water Services (2009). Goose Creek Water Quality Recovery Program Plan for Fecal Coliform TMDL. Version 2: November 12, 2009. North Carolina Department of Environment and Natural Resources (NCDENR) (2000). Laws And Rules for Sewage Treatment, and Disposal Systems. 15A NCAC 18A. 1900. NCDENR, Department of Environment and Natural Resources Division of Environmental Health On-site Wastewater Section. NC Wildlife Resources Commission (NCWRC), NC Natural Heritage Program (NCHP), (2005). Technical Support Document for Consideration of Federally -listed Threatened or Endangered Aquatic Species in Water Quality Management Planning for the Goose Creek Watershed. Goose Creek TSD 073105revision review draft. U.S. Centers for Disease Control and Prevention [USCDC]. (2009). Healthy Housing Reference Manual, Chapter 10. On -Site Wastewater Treatment. Retrieved January 28, 2012 from http://www.cdc.gov/nceh/Tublications/books/housing/chalo.htm U.S. Fish and Wildlife Services. (2011). Carolina heelsplitter. Ashville Ecological Services Field Office, Ashville, NC. Retrieved January 28, 2012 from http://fws.gov/asheville/htmis/listedspecies/Carolina heelsplitter.html 25 Appendix 1. Map and location of on-site wastewater system inspections in the Goose Creek Watershed . 0 Septic Inspections In The Goose Creek Watershed o 0 po O 0O q° o00 o , 0 0.O ol To o O of �co8°° ° a of° 0 0 0 � 00 , 0°° 0 °o o O O O® 5 8�aA511P4 °o ° ���LLLfffiiS{{{555U6U6U6 oo 0 0 m °S 8 o O R° O O ccyY o°Oo° ° q8 00 / ob 0 00° °. Opo °O B B O o80 ��OC� O vq O B 00 O °O O OO rBnslN �o O °Oo0 O 0 O 0° 00 O 1 8Y,Qi 8 O OM �o O e IN13 �. 0 0 ° o .o ° °° o �� o I og o � o o 0 3,800 7,600 1 inch = 2,642 feet B _on° 8 o Oo o �Op o O p ° °o oe o 0 ooh Wnslrvfa 8 000 15 200 Fee[ Legend e High Rlsk Septic Ippedi ons O Septic l nspect,o + Fali,g Septic Systems Wth,,400ftofSream 5[ream s � Irfters[ale 400fi SYream BURer OParcels Served By Waste Water Trea[m erft PI.. Basins 'all other values BRSIN_ID 19 sIN1 BASUN BASIN11 13 sIN1z BAS IN , Bn IN14 BASIN2 BA IN3 BASIN4 BASINS 13 SIN BASIN] 13 SIN8 BASUN Streets OParcels G.— Creek Watershed This map was created by Jeremy Michael on December 1, 2011. This map was created for GIS 510 North Carolina State University. Data used in this map was obtained from Mecklenburg County GIS Intranet folder %%meckgismapimageld, and the Mecklenburg County nternal5hared docume"Itsfolder(xfer)onthel drive. The useof this map was intended for Mecklenburg County Groundwater and Wastewater Services Department. Appendix 2. On-site wastewater system inspection form used in the Goose Creek Watershed Inspection Date: Site Parcel Id #: GWS File #: Septic System Information: System Classification: ❑ II ❑a ❑ b System Description: Septic System Inspection Form Inspection Completed By: Site Address: Watershed: El III El IV ❑V F-1 vi El El El El El Groundwater & Wastewater Services Catchment Id: 700 N. Tryon St., Suite 211 Charlotte, NC 28202 Ph: 704-336-5103 (Ex: pump to 25% reduction) Year Operation Permit Issued: (If no permit record is available use built date year from POLARIS.) System Age: Years ❑ Actual ❑ Estimated Inspection Information: Comments Site accessible for inspection: ❑ Yes ❑ No Owner present: ❑ Yes ❑ No Drain field probed: ❑ Yes ❑ No System malfunction observed: ❑ Yes ❑ No Notice of Violation required: ❑ Yes ❑ No System located <200 ft. from ❑ Yes ❑ No surface water body: System located <50 ft. from ❑ Yes ❑ No stormwater BMP or diversion: Trees/vegetation in drain field: ❑ Yes ❑ No Irrigation on drain field: ❑ Yes ❑ No Well(s) located on property: ❑ Yes ❑ No General comments/observations: # photos taken: Dye Pack Left: ❑ Yes ❑ No Signature: 27 Appendix 3. Information pamphlet used in the Goose Creek Watershed. About your watershed The baose Creek watir-sired is made of 9z square miles in Ltion and Medllanburg wurrf;es wdndudes perm d hTrttl�. The watershed 's home m the Card'na heelspimer mussel which was res added m the federal endangered :spades list in 1993. n order m promR the rater quality and habitat needed msm hu' an reocaaer {ard'nahaelspimer populaticn, a setof tnanagemercrulas were deuekaped and appramd by the N. C. Department of Ehruirann•nnt& Naeural Hesdrraas [NCI]ENR). hi order m comply with the rules put forth b7 the Stam, the Town of Mont Hi and lledlen r[p {maty establdwd a Water Quality Reoo1eery Plan QWWP) lorfeEEl culfform in deo 6a Creek Wubrstred- The Trane pack d the MRP is m idwtty and ramora sournas d feel ookform in the Water had. Storm Wafer 5Serkems has oondu�.ed field surveys of the wetershed'nddieg the sampling errs idernfic tion of al s -o m w .er outfalls, in -stream s prrg and saaenn walks of the mire w .Bmtlsd. Threw effor3 here nit been suooes_dul in dermfykg w rtes of fecal chcliforrn. The one rennanenq potent" source -hat hes ye- to be dhn r uo* onuestip kmd is septic systems. Septic systems are being targeted beaa4r4e the vast m** of the fimr a Creek W whershrd does nd saris a municpel sanitary serer system. About your septic system A typml septic system hes four ..in components: a pp. From the horn., a septic tank_ a drainfAd, and the sai. Mi—bas in the soil digest or remove most ccntaminerhts from wastewater before it—tually readies groundwaim rb�a4rr sa sa Graana.eller Homearmers are respors laforthe care and maintanenca -= -he4 s=.-ic <--- -h raa. ra• E ;;E a•a .;.?z _.... ... .. -: -o .as✓E �o.: 5y5:E --,erars.r 'E'8re: • _, -9413 p, mpirg of the sept g. from the septic ar.c. i L—d.tF. naptic ta,k lid a,d keep it merkEdL i Kn—wF.t-Fa T nirm wai--arca requirements are 1,r V., :ype cf -.pt, Er -,— i '.spo-d t, a tai ng s),tem with r.q.ir.d -i.r-e: ar_, p3r:ica arlywhen —Fta frig of ALent ccxurs or r.dor5 are apparent i Keep records of the system desgn, 1-dicn and maintenance adNifi s (indhding pumping detms . lieepiny year :y:tem functioning properly prevent: ih—p—d of inlection and di:ease and preteets water re ee ureas. For questions ccro rrvng septics inns, well. and ground wabsr issues contact 6rwnrdwatw & Wasterrater Services 704-336-5103 wa I k ag @dnn ee k len bu rgeau n tyro. gore For qu tsticns ocnoeming the Water Qua* Recu y Plan d the 5unme Creek watershed oontad David Kroening 704-33Cr5448 dairidLknoonirq@nneckIenhurgcaunt mc.gov About your inspection Prio• -o - a ; = a c up ctiehh the inspector reviewed the Farr: ssaec rr ars:alaf— of the system and looked at recent aerial plxabgraphyta idarCytha location of the system. The inspadormaf haue'prahad'the arae of the drain field to determine the an3tion of the tan L and drain lines and any rapairareas. The inspadur locked for vgns of e mallu,ct mg syA— Y—optic 5),stam was inspected on: ihspecWra name: Inspector's c—Led number: Twr impaction showed: ❑ No pral,k—. system furthering —, dly ❑ P -ring sewage on the hand wrf— ❑ Trees growing in the drain field ❑ Irrigation of the drair fell Please call the above in:pecter directly H you here q—ti— or con cern. a6vut the inspection aF your septic system. A Guide for Homeowners sit-PhC sy5b--m5 iin Coo5e Creek aLer5hed To prated your ground and surface watw msawca Tips for a healthy system Akh.ugh aaamErhteral optr system hes m —img pees and ncrmellj locos[ require rreeUy yr hly meintena-i a:tentim met be paid to cone g3nerd prndp� of maim.— Impw-arr. malt—not pr—i— mriude the followN: Oep prize ureter usage. • depeileelyteu-Hs endicila:s prump:F{ • Rin dshrra;h.rs 6 rredhig nechinas tnyn lull hods • Turn water elf while shaving, bru;Hng teeth, — hing dishes, etc • h¢ull 1—fi w faucets end wa[e—ing =_h s.arheads. Provide adequate site drainage • Drect gutm•s and c..nspouts -q from the sepdctank and cninh.d. a ao notdrihe oueror park onthe dminfield. Use proper landscaping. • Aheehty g•sss ;a.e• s�.ud to main-3ined Quer the drir'ec ro p•evem sail erosion • Trees enc sieves should not be plumbed too cloy m the draidield. i Na structures, sheds, pooh, patios, or paned Euff—ss hddd he mnstrucmd averse sapdc t :r c'31'Ih9 d a -- Use -Ilse sound waste disposal practice �.-..... ... .... . .E. Ecco tum 6 C— • -:E' i - - ::E5 • _ -s•q nae ': • = e, ort • -i- ��15 • —"E .A. n—,lom wash For mare kip: on septic :yxtenh: risit http:flr reandwater.eh armeek. cry. 28 Appendix 4.Goose Creek Watershed on-site wastewater system failure chart NOV Issued System Age (years) Design Flow Failing System Code Failure Type Primary Cause LTAR Remedy Code Compliance Achieved By: 4/30/2009 30 600 GPD Gravel Bed SD -Discharge to surface Excessive Water Usage/ Many kids home schooled, 0.3 Tire Chip Bed Septic system repaired 5/18/2009 32 360 GPD Gravel Bed/Washer Line SD -Discharge to surface Damaged or Destroyed 0.3 Gravel Bed Washer lime repaired 5/27/2009 32 360 GPD Gravel Bed SD -Discharge to surface Excessive Water Usage/ Had many visitors N/A Terra Lift Maintenance 3/15/2010 10 480 GPD Gravel Drain Lines SD -Discharge to surface Excessive Water Usage/Leak in house 0.3 Tire Chip Bed Septic system repaired 2/10/2010 37 360 GPD Gravel Bed SD -Discharge to surface Site Problems/Buikling over Drainfield 0.3 Tire Chip Bed/Int. Drain Septic system repaired 4/19/2010 36 360 GPD Gravel Bed SD -Discharge to surface Excessive Water Usage/ 10 people living there 0.3 Tire Chip Bed Septic system repaired 3/23/2010 38 360 GPD Gravel Bed SD -Discharge to surface Age/ Normal Exhaustion/ Roots 0.3 Tire Chip Bed Septic system repaired 11/16/2010 38 240 GPD Gravel Bed SD -Discharge to surface Excessive Water Usage/Leak in house N/A Fixed Leak Maintenance 11/29/2010 23 480 GPD Gravel Trench SD -Discharge to surface Excessive Water Usage/Leak in house N/A Terra Lift/ fixed leak Maintenance 12/15/2010 55 360 GPD Gravel Bed SD -Discharge to surface Age/ Normal Exhaustion/ Roots N/A Roots/Cleaned Out Maintenance 4/18/2011 47 360 GPD Gravel Bed SD -Discharge to surface Straight Piped Wash Water 0.3 Tire Chip Bed Washer lime repaired 2/23/2011 100 360 GPD Gravel Bed SD- Discharge to surface Damaged or Destroyed -Lids on septic tank broken N/A Tank lids replaced Maintenance 29 Mitigation Services ENVIRONMENTAL OVALITY May 21, 2018 Nicole Bartlett Charlotte Water 5100 Brookshire Blvd Charlotte, NC 28216 Project: Stevens Creek Trunk Sewer Phase 1 ROY COOPER Govemor MICHAIEL S. REGAN Secretary Expiration of Acceptance: 11/21/2018 County: Mecklenburg The purpose of this letter is to notify you that the NCDEQ Division of Mitigation Services (DMS) is willing to accept payment for compensatory mitigation for impacts associated with the above referenced project as indicated in the table below. Please note that this decision does not assure that participation in the DMS in - lieu fee mitigation program will be approved by the permit issuing agencies as mitigation for project impacts. It is the responsibility of the applicant to contact permitting agencies to determine if payment to the DMS will be approved. You must also comply with all other state, federal or local government permits, regulations or authorizations associated with the proposed activity including G.S. § 143-214.11. This acceptance is valid for six months from the date of this letter and is not transferable. If we have not received a copy of the issued 404 Permit/401 Certification/CAMA permit within this time frame, this acceptance will expire. It is the applicant's responsibility to send copies of the permits to DMS. Once DMS receives a copy of the permit(s) an invoice will be issued based on the required mitigation in that permit and payment must be made prior to conducting the authorized work. The amount of the in -lieu fee to be paid by an applicant is calculated based upon the Fee Schedule and policies listed on the DMS website. Based on the information supplied by you in your request to use the DMS, the impacts for which you are requesting compensatory mitigation credit are summarized in the following table. The amount of mitigation required and assigned to DMS for this impact is determined by permitting agencies and may exceed the impact amounts shown below. River Basin I Impact Location Impact Type Impact Quantity Yadkin i Goose Creek I Zone 1 1 Up to 121,546 ft2 Upon receipt of payment, DMS will take responsibility for providing the compensatory mitigation. The mitigation will be performed in accordance with the In -Lieu Fee Program instrument dated July 28, 2010 and 15A NCAC 02B .0295 as applicable. Thank you for your interest in the DMS in -lieu fee mitigation program. If you have any questions or need additional information, please contact Kelly Williams at (919) 707-8915. cc: Jason Marshall, agent Sincerely, James.: B Stanfill Ash anagement Supervisor State ofNorth Carolina I Environmental Quality I Mitigation Services 1652 Mail Service Center I Raleigh, NC 27699-1652 1 217 W. Jones Street, Suite 3000 919 707 8976 T Pipe — Specifications and Testing SECTION 02601 PRECAST CONCRETE MANHOLES AND STRUCTURES PART1 GENERAL 1.01. DESCRIPTION A. Scope 1. CONTRACTOR shall furnish all labor, materials, equipment, and incidentals required to furnish and install all precast concrete manholes and structures as shown, specified and otherwise required to complete the Work. a. The Work includes, but is not limited to the following: 1) Precast concrete manholes. 2) Precast concrete structures and catch basins. 3) Frames and covers. 4) Inside drop manhole connections. 5) Manhole and structure testing requirements. 2. Structures shall conform in shape, size, dimension, material, and other respects to the details shown or as ordered by the ENGINEER. B. Coordination 1. Review the work under other sections and coordinate with the work that is related to this Section. C. Related Work Specified Elsewhere 1. Section 02222 — EXCAVATION 2. Section 02223 - BACKFILLING 3. Section 02225 — TRENCHING 4. All other related sections for piping, appurtenances and specials. 1.02. QUALITY ASSURANCE A. Reference Standards 1. ASTM A 48, Gray Iron Castings. 2. ANSI A 14.3, Safety Requirements for Fixed Ladders. 3. ASTM B 221, Aluminum Alloy Extended Bars, Rods, Wire Shapes and Tubes. 4. ASTM C 478, Precast Reinforced Concrete Manhole Sections. Stevens Creek Trunk Sewer Phase 1 PRECAST CONCRETE Charlotte Water Job No. 7030700047-17-503 02601-1 MANHOLES AND STRUCTURES ASTM C32, Sewer and Manhole Brick (made from clay or shale). 1.03. SUBMITTALS A. Shop Drawings 1. Submit for approval Shop Drawings of design and construction details of all precast concrete. 2. Submit for approval manufacturer's certification of brick, block, gaskets, precast sections, frames, covers, and all other accessories required. 3. Shop Drawings for the fabrication and erection of all casting assemblies and miscellaneous metal work. 4. Copies of manufacturer's specifications, load tables, dimension diagrams, anchor diagrams, and installation instructions for products to be used for miscellaneous metal works and casting assemblies. 5. Certified copies of factory test reports for manholes. 6. All precast concrete structures shall be designed by a licensed North Carolina State Registered Professional Engineer. Each Drawing for design shall be stamped and signed by the Licensed North Carolina State Professional Engineer. 1.04. PRODUCT DELIVERY, HANDLING AND STORAGE A. Delivery: All necessary precautions shall be taken to prevent damage to precast concrete sections, cones, bases, frames and covers and other materials during shipment and delivery. All materials shall be securely fastened to truck or rail car to prevent movement or damage during shipment. Inspector shall examine all materials before unloading. B. Handling: All precast concrete materials shall be handled to prevent damage. Precast concrete sections shall not be dropped, rolled, or pushed off from any height on delivery, storage or installation. C. Storage: All precast concrete materials shall be stored in such a manner as to safely protect the structures at all times. PART PRODUCTS 2.01. PRECAST CONCRETE MANHOLES AND STRUCTURES A. General: The following requirements apply to all precast concrete manholes and structures furnished on this Project. Precast Concrete structures shall be manufactured in accordance with ASTM C478, latest revision, and shall be designed for HS -20 live load, latest revision. 2. Precast concrete manholes and structures shall be of approved design and of sufficient strength to withstand the loads to be imposed upon them. Mark date of manufacture and name or trademark of manufacturer on inside of structure. Stevens Creek Trunk Sewer Phase 1 PRECAST CONCRETE Charlotte Water Job No. 7030700047-17-503 02601-2 MANHOLES AND STRUCTURES 4. All precast concrete structures shall be installed on a base of select backfill material as shown on the Contract Drawings. All concrete in precast units shall be stone aggregate and develop strength of 4,000 psi at 28 days and shall conform to the following specifications: a. All concrete furnished for precast concrete manholes and structures shall be in accordance with ACI 318 Code for reinforced concrete. b. Materials 1) Cement: Portland cement, ASTM C150, Type I or Type 11. 2) Admixtures: Admixtures other than air entraining admixture shall not be used. Air entraining admixture shall conform to ASTM C260. Air content of concrete with 3/4 -inch maximum size aggregate shall be 6 percent plus or minus 1 percent volume. Water: Clean and free from injurious amounts of oils, acids, alkalis, organic materials or other substances. Aggregates: Aggregates shall conform to ASTM C33, latest revision. Course aggregate shall be size number 67 (nominal 3/4 -inch to No. 4). e. Proportions: Proportions of materials in concrete and strength of concrete shall be subject to the following conditions: 1) Minimum 28 -day compressive strength — 4,000 psi 2) Maximum water to cement ratio by weight — 0.45 3) Minimum cement content (pounds per - 600 lbs/cubic yard) 6. All precast concrete shall be manufactured by wet cast methods only, and shall be approved design. 7. All precast concrete shall be steel reinforced. Reinforcing shall be designed for all applicable loads and forces encountered. Steel reinforcing shall be ASTM A496 -A, 615, Grade 60-60 KSI. 8. Prior to backfilling, all below grade exterior faces of the precast concrete manholes and structures installed on sanitary sewers shall be painted with an asphaltic sealer as shown on the Drawings. Sealer shall be manufactured by one of the following: a. RC -70 Protective Coating as manufactured by Midland Asphalt b. Bitumastic 300M as manufactured by Carboline Or equal 9. If cast -in-place bases are required, the concrete and reinforcing shall conform to the Specifications as outlined under Section 03001 10. All holes and cutouts for adjacent piping shall be no less than 6 inches from any joint in the structure at either the top or bottom of the line on any branch piping. Stevens Creek Trunk Sewer Phase 1 PRECAST CONCRETE Charlotte Water Job No. 7030700047-17-503 02601-3 MANHOLES AND STRUCTURES 2.02. PRECAST CONCRETE MANHOLES A. In addition to the general requirements for precast concrete structures outlined above, the following shall apply: 1. Precast concrete manhole bases shall be monolithic reinforced concrete and shall have an O-ring gasket as outlined for the manhole sections. Thickness of the bottom of precast concrete manhole bases shall be a minimum of 6 inches for 48 -inch diameter manholes and a minimum of 8 inches for 60 -inch diameter manholes. 2. Precast concrete manhole bases shall be provided with a base flange extending no less than 6 inches beyond the outside walls of the monolithic base. 3. Unless a larger size is required by the Drawings, the barrel of the precast concrete manholes shall be constructed of standard reinforced concrete manhole sections. The barrel shall be constructed of various lengths of pipe in combination to provide the correct height with the fewest joints. Wall sections shall not be less than 5 inches thick for 48 -inch diameter manholes, or less than 7 inches thick for 60 -inch diameter manholes. 4. Joints shall be rubber gasket and concrete using O-ring gaskets, conforming to AWWA C302. For rubber ring joints, the base of the bell shall be buttered with 1:" cement -sand ratio to provide a uniform bearing for the spigot of the entering pipe. 5. A precast slab or precast eccentric cone with a minimum opening of 24 inches shall be provided at the top of the manhole barrel to receive the cast iron frame and cover. The slab or cone shall be of acceptable design and of sufficient strength to safely support an HS -20 loading. Concrete slabs shall not be less than 8 -inches thick. 6. Manhole sections shall contain manhole steps, 12 inches on centers, accurately positioned and embedded in the concrete. 7. Where the proposed piping passes through exterior walls of a precast concrete manhole on structure, the manufacturer shall provide an oversized opening and mechanical type seal or shall provide an assembly consisting of a flexible rubber boot with clamp assembly. The boot assembly shall meet the requirements of ASTM C- 923 and shall have a stainless steel power sleeve and clamps. 8. Product and Manufacturer: a. Precast concrete manholes shall be manufactured by: 1) Kistner Concrete Products 2) Or approved equal. 2.03. PRECAST CONCRETE CATCH BASINS A. In addition to the general requirements for precast concrete structures outlined above, the following shall apply to precast concrete catch basins: Precast concrete catch basins shall be manufactured as one- or two-piece units with integral bottom and wall cast in one pour per piece so that there are a minimal number of joints present in the sections. Stevens Creek Trunk Sewer Phase 1 PRECAST CONCRETE Charlotte Water Job No. 7030700047-17-503 02601-4 MANHOLES AND STRUCTURES 2. Catch basin base and walls shall be of acceptable design and of sufficient strength to safely support HS -20 loading. 3. For precast concrete base section, the minimum thickness of base slab shall be 6 - inch thickness or other thickness as recommended by the manufacturer. 4. Precast concrete walls for catch basin shall be 6 -inch thickness except at knockouts where the minimum thickness shall be 2 inches. 5. Pipe connections to catch basins for storm drainage piping shall consist of a knockout in the catch basin wall for installation of the proposed piping. The void between the proposed piping and the wall of the catch basin shall be grouted with cement -mortar grout and shall be approved by the ENGINEER. 2.04. MISCELLANEOUS METALS A. Steps and ladder rungs (manholes) 1. The CONTRACTOR shall provide steel reinforced copolymer polypropylene steps as follows: a. Conform to requirements outlined in ASTM 2146 under Type II, Grade 16906. b. Steel reinforcing used in steps shall be continuous 1/2 -inch diameter reinforced rod. C. Steel reinforcing rod shall be Grade 60 and conform to requirements of ASTM A-615. d. "Press Fit" step hand driven by hammer into preformed holes in the precast concrete manhole sections. e. Steps shall be in conformance with ASTM C-478, paragraph 11 and shall be in conformance with all applicable OSHA standards. f. Space steps uniformly at a maximum of 12 inches on centers and project evenly from manhole or chamber walls. 2. Product and manufacturer: Provide one of the following: a. M.A. Industries, Inc., Model PS -2 -PFS b. Or equal. B. Frames and covers: (Manholes) 1. For manholes, provide frames and covers as follows: a. For sewer manholes, frames and covers shall conform to the following: 1) Made from merchantable gray cast iron, tough, even -grained, and free from all flaws or defects, ASTM A48, Class 35, cast iron, or equal. b. Frame and cover shall be rated for HS -20 loading, latest revision. Stevens Creek Trunk Sewer Phase 1 PRECAST CONCRETE Charlotte Water Job No. 7030700047-17-503 02601-5 MANHOLES AND STRUCTURES C. Machined to ensure proper fit and even bearing in all positions. d. Covers shall be solid covers and shall be furnished without lettering. e. Covers within the 100 -year flood plain shall be furnished with watertight gasket and two (2) camlocks. f. Covers outside of the 100 -year flood plain shall be furnished with one (1) each, 1 -inch diameter vent holes, and two (2) Cored Pickbars as shown on the Drawings. g. Manhole frame and cover shall be furnished in accordance with the details shown on the Drawings. 2.05. DROP MANHOLE CONNECTIONS A. Drop manhole connections shall conform to the design and details shown, or as directed by the ENGINEER, and shall be constructed where shown on the Drawings. B. Install inside drop manhole connections at all sewers entering a manhole where the proposed sewer enters the manhole at an elevation of 24 inches or more above the manhole invert. C. The inside drop manhole connection shall be constructed of the following components: Inside drop bowl assembly, Model A-6 as manufactured by Reliner/Duran Inc. or equal. 2. Schedule 35 PVC piping and fittings to complete installation. D. The drop connection shall be attached to the manhole wall using 1/4" x 2" stainless steel strap with two (2) anchor bolts. A minimum of two clamping brackets shall be installed for each drop connection. E. Connection between the drop bowl assembly and the PVC drop piping shall be completed using a Fernco coupling. F. Install suitable bend at bottom of drop connection to direct flow into the existing manhole invert/bench. G. Installation of drop manhole connections shall not interfere with the existing manhole access or steps. PART 3 EXECUTION 3.01. INSTALLING PRECAST CONCRETE STRUCTURES A. Precast concrete structures shall be installed and set in accordance with the manufacturer's recommendations and as outlined herein. 3.02. MANHOLE BASES AND CATCH BASINS A. Precast and cast -in-place manhole bases and concrete catch basins shall be set on a concrete or crushed stone foundation base as shown. Bases shall be set at the proper grade and carefully leveled and aligned. Cast -in-place bases shall conform to the details shown on the Drawings and shall be constructed in accordance with Section 03001. Stevens Creek Trunk Sewer Phase 1 PRECAST CONCRETE Charlotte Water Job No. 7030700047-17-503 02601-6 MANHOLES AND STRUCTURES B. Set sections vertical with steps and sections in true alignment. C. Install sections, joints, and gaskets in accordance with manufacturer's recommendations. D. Lifting holes shall be sealed tight with a solid rubber plug driven into hole and the remaining void filled with 1 to 2 cement -sand mortar. 3.03. MANHOLE CHANNELS A. Inverts shall conform to the size and elevation of the adjoining pipes. Side inverts shall be curved and main inverts, where direction changes shall be laid out in smooth curves of the longest possible radius which is tangent to the centerline of the adjoining pipelines. B. For straight through flow, channels shall be formed from polyvinyl chloride (PVC) pipe laid through the manholes. A bench of 4,000 psi concrete shall be built up to the 2/3 point of the vertical sewer diameter before the top of the sewer pipe is broken out. C. Where side channels and curved sections occur, the channels within the manholes shall be formed of 4,000 psi concrete and shall be given a hard trowel finish. 3.04. GRADING AT MANHOLES AND CATCH BASINS A. Precast concrete grade rings shall be used for all precast manholes, structures and catch basins where necessary to set frame and cover to final elevations. Grade rings shall be maximum of 6 inches (2 -inch, 4 -inch, or 6 -inch), and shall not exceed 12 inches in total height, constructed on the roof slab or cone section on which the frame and cover shall be placed. The height of the grade rings shall be such as is necessary to bring the frame and cover to the proper grade. However, no more than two grade rings will be allowed. B. Concrete blocks or bricks shall be used to set new frames and grates on new or existing catch basins. C. All manholes in unpaved areas shall be built as shown or directed to proper elevation. 3.05. MANHOLE WATERTIGHTNESS A. All manholes shall be free of visible leakage. Each manhole shall be tested for leaks and inspected, and all leaks shall be repaired in a manner subject to the ENGINEER's approval. B. After installing manhole sections and making O-ring joints, CONTRACTOR shall trowel on inside and outside face of joint mortar coating, "PRECO-PATCH" or equal. 3.06. PIPE JOINT A. Materials required for pipe stubs shall be of the same make and manufacture, including lining and coating of the main adjoining piping. 3.07. CONNECTIONS TO EXISTING MANHOLES AND CATCH BASINS A. The CONTRACTOR shall make connections between the proposed manholes and the existing manholes where shown on the Drawings, and between proposed catch basins where shown and required. B. The CONTRACTOR shall core drill into the existing manhole at the locations shown on the Drawings and at the elevations shown on the Drawings and at such an angle so that no reverse flow conditions will be created and so that the core drilling does not interfere with the existing pipes. Stevens Creek Trunk Sewer Phase 1 PRECAST CONCRETE Charlotte Water Job No. 7030700047-17-503 02601-7 MANHOLES AND STRUCTURES C. If the existing manhole has a bench and channel, it shall be removed and reconstructed to permit flow through the manhole as it exits now and also into the new outlet pipe. The CONTRACTOR shall be responsible for diverting flow or pumping water so that a channel and bench may be constructed in a dry condition. D. Diversion of the water flow shall only be done with the approval of the ENGINEER and the agency involved. E. Subsequent to construction of the connecting pipe and the connection to the existing manhole and before the diversion or pumping procedures are stopped, the CONTRACTOR shall install a plug in both the inlet and outlet ends of the pipe connections of the proposed manhole and the existing manhole. The plugs shall be secured to a chain which shall be secured to the manhole in which it is installed. The plugs shall be watertight. 3.08. ADJUSTMENT OF FRAMES, COVERS AND GRATES AND INSTALLING NEW FRAMES, COVERS AND GRATES A. Frames, covers and grates shall be adjusted to new grades necessary to match final pavement surface. B. Limits of excavation and pavement removal shall be kept to the minimum necessary to complete the work. C. Provide all blocks, bricks and appurtenances necessary for grade adjustment. D. CONTRACTOR is responsible to ensure, check and verify all grades. END OF SECTION Stevens Creek Trunk Sewer Phase 1 PRECAST CONCRETE Charlotte Water Job No. 7030700047-17-503 02601-8 MANHOLES AND STRUCTURES SECTION 02733 SANITARY SEWER PIPING PART1 GENERAL 1.01. SECTION INCLUDES A. Gravity flow sanitary sewers, fittings, accessories, including outfall sewers, materials and installation. B. Connection of sanitary sewers to manholes. C. Tests and inspections. D. Pipe Schedule. 1.02. RELATED SECTIONS A. Section 02225 - TRENCHING B. Section 02228 - COMPACTION C. Section 02734 — MANHOLES AND COVERS D. Section 02735 - LEAKAGE TESTS OF SEWERS 1.03. REFERENCES A. Ductile Iron Gravity Sewer Pipe ASTM A746 Ductile Iron Gravity Sewer Pipe AWWA C151 Ductile -Iron Pipe, Centrifugally Cast AWWA C104 Cement -Mortar Lining for Ductile Iron Pipe and Fittings ANSI/AWWA Push -On Joints and Mechanical Joints A21.11/C111 B. Plastic Gravity Sewer Pipe AWWA C900 Polyvinyl Chloride (PVC) Pressure Pipe and Fabricated Fittings, 4 In. Through 12 In. (100 mm Through 300 mm), for Water Transmission and Distribution ASTM D1784 Standard Specification for Rigid Poly(Vinyl Chloride) (PVC) Compounds and Chlorinated Poly(Vinyl Chloride) (CPVC) Compounds Standard Specification for Joints for Plastic Pressure Pipes Using Flexible ASTM D3139 Elastomeric Seals ASTM D2412 External Loading Properties of Plastic Pipe by Parallel -Plate Loading Standard Specification for Resilient Connectors Between Reinforced ASTM C923 Concrete Manhole Structures, Pipes, and Laterals Elastomeric Seals (Gaskets) for Joining Plastic Pipe ASTM F477 1.04. SUBMITTALS Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02732-1 SANITARY SEWER PIPING A. Submit under provisions of Section 01300, Submittals. B. Product Data - Provide data indicating conformance to ASTM/AWWA codes, pipe material, sizes, class, dimensions, joint type, and pipe accessories. C. Manufacturer's Installation Instructions - Indicate special procedures required to install Products specified. D. Results of shop tests, if required. E. Manufacturer's Certificate - Certify that products meet or exceed specified requirements. 1.05. PROJECT RECORD DOCUMENTS A. Submit documents under provisions of Section 01700, Record Documents. B. Record location and length of pipe runs, connections, manholes and rim and invert elevations. Invert elevations to be of the pipe invert at a point where the pipe enters or exists a structure. C. Identify and locate on record drawings the discovery of exposed uncharted existing utilities and services. 1.06. REGULATORY REQUIREMENTS A. Conform to applicable NCDEQ code for materials and installation of the Work of this Section. B. Conform to requirements of permits obtained by Owner and attached to these Specifications. 1.07. FIELD MEASUREMENTS A. Prior to construction, verify by field measurements and exploratory excavations that existing facilities locations and elevations are as shown on Drawings. Notify Engineer of potential inferences and allow Engineer sufficient time to determine any changes required as a result of such interferences. 1.08. COORDINATION A. Coordinate work under provisions of Sections 01039, Coordination and 01500, Temporary Facilities, including field engineering, maintenance of traffic, access to private driveways, emergency vehicle access and areas with shared with other contractors. B. Coordinate the Work with termination of sanitary sewer and connection of existing sewers with Charlotte Water. Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02732-2 SANITARY SEWER PIPING PART PRODUCTS 2.01. GRAVITY SANITARY SEWER PIPE MATERIALS A. Ductile Iron Pipe: 1. Ductile Iron Gravity Sewer Pipe - ASTM A746, Class 250 and 350, bell and spigot. 2. Ductile Iron Pipe Joint Devices - ANSI A21.11 rubberjoint device. B. Plastic Pipe (8 inches to 24 inches) — AWWA C900, ASTM D1784, Cell Class 12454, Poly (Vinyl Chloride) (PVC) material; minimum pipe class DR25 (Rate 165 psi); bell and spigot style with rubber gasket conforming to ASTM D3139 and ASTM F477 respectively. Pipe color shall be green. 2.02. PIPE ACCESSORIES A. Fittings - Same size, material and class as pipe molded or formed to suit pipe size and end design, in required tee, bends, elbows, cleanouts, reducers, couplings, adopters, traps and other configurations required. B. Trace Wire - Magnetic detectable conductor, green plastic covering, standard #12 AWG copper tracer wire. C. Pipe Connections 1. Male End of New Sewer Pipe to Female of Existing Pipe - Fernco Inc. Standard Flexible Couplings; or equal. 2. Male End of New Sewer Pipe to Male End of Existing Pipe - Fernco Inc. Standard Flexible Couplings; Dresser Model 360 "All -Around" Pipe Repair Clamps in Stainless Steel; or equal. D. Identification Each pipe length and fitting shall be clearly marked with: 1. Manufacturer's name and trade mark. 2. Nominal pipe size and class. 3. Material designation. E. Connections to Manholes 1. 8" pipe to 16" pipe - Provide flexible watertight boots cast in as integral part of manhole base or installed in cored opening with stainless steel compression band conforming to ASTM C923. 2. 18" pipe and larger may be furnished with manhole precast bottom section with flexible boots, flexible seals, or concrete collars. Flexible seals shall be A -Lok or Contour Seal. Connections shall meet ASTM C923 and connections details in Contract Drawings. 2.03. SHOP TESTS Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02732-3 SANITARY SEWER PIPING A. General 1. All shop tests of pipe and pipe materials required by this section and/or the applicable ASTM/AWWA Specifications shall be performed at the Contractor's expense. 2. When no specific shop tests are required, the manufacturer shall submit a Performance Affidavit certifying his product meets or exceed these specifications and the applicable ANSI/ASTM and AWWA requirements. If required by the Engineer, certified test reports of prior tests shall be submitted with the performance affidavit. 3. Tests shall be conducted at the pipe manufacturer's plant or when approved test facilities do not exist at the point of manufacture, the tests shall be conducted in certified private testing laboratories approved by the Engineer. 4. All testing machines, gages, laboratory apparatus and other devices used for the required shop tests shall be in first class condition and accurately calibrated. Shop tests shall be conducted by qualified personnel. 5. The Contractor shall submit to the Engineer the name or names of the proposed manufacturers of pipe for this project, including shop drawings of the proposed pipe and appurtenances. Each pipe manufacturer shall notify the Engineer and the Contractor when shop tests on the lot or lots of pipe for this project are to take placed, allowing sufficient time for the Engineer to send a representative to witness the tests. 6. Tests shall be conducted in accordance with the applicable ANSI/ASTM or AWWA specifications except as modified by these specifications. 7. Wherever in the appropriate ANSI/ASTM or AWWA Specification tests are required to be performed for all pipe furnished for this project, certified copies of all test (and retest) results shall be submitted jointly to the Engineer and the Contractor unless the foregoing Paragraph No. 3 applies. 8. Specific modifications and/or amendments to the applicable ASTM Specifications are as follows: a. Crushing Strength - Crushing strength tests shall be conducted using the 3 - edge bearing method except that the lower bearing strips utilized in these tests may be of hardwood or hard rubber material complying with the applicable ASTM Specification, unless such option is precluded under the companion ASTM Specification which covers the pipe itself. 9. Specimens showing obvious leakage in the pipe wall or at the joint, which will prevent compliance with the required leakage tests in the field, shall be tagged and rejected. If the joint assembly itself is suspected as the only cause for leakage, another test may be run on the same specimens using another set of gaskets and couplings. If this leakage test is met, the original gaskets and couplings shall be rejected, although the pipe sections themselves may be shipped. 10. Upon completion of shipment of the pipe furnished for this project, the pipe manufacturer shall provide the Engineer with a certificate, signed by an officer of the corporation or firm and witnessed by a notary public, attesting that the pipe and Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02732-4 SANITARY SEWER PIPING appurtenances furnished were manufactured and successfully tested in full accordance with these specifications and the applicable ASTM Specifications. 11. Any section or lot of pipe, fittings or specials which does not meet the requirements of these specifications and the applicable ASTM/ANSI or AWWA Specifications under which the product is required to be manufactured, will be rejected. PART 3 EXECUTION 3.01. EXAMINATION A. Verify that trench cut, excavated base and pipe bedding is ready to receive work and pipe bedding dimensions and elevations are as indicated on Drawings. B. All pipe, fittings, and specials shall be carefully inspected in the field before lowering into the trench. Cracked, broken, warped, out -of -round, damaged joints, including damaged pipe linings or coatings, or otherwise defective pipe, fittings or specials, as determined by the Engineer, shall be culled out and not installed. Such rejected pipe shall be clearly tagged in such manner as not to deface or damage it, and the pipe shall then be removed from the job site by the Contractor at his own expense. C. Any pipe showing a distinct crack with no evidence of incipient fracture beyond the limits of the visible crack, if approved, may have the cracked portion cut off by, and at the expense of, the Contractor before the pipe is laid so that the pipe used is perfectly sound and will form an approved joint. The cut shall be made in the sound barrel at a point at least 12 inches from the visible limits of the crack. D. If authorized, cutting of the pipe shall be done in a neat and workmanlike manner without damage to the pipe lining. All pipe cutting shall be done by means of an approved type of power cutter and in accordance with manufacturer's instructions. The use of hammer and chisel, or any other method which results in rough edges, chipped or damaged pipe, is prohibited. 3.02. PREPARATION A. The Contractor shall have on the job site with each pipe laying crew, all the proper tools, gauges, pipe cutters, lubricants, etc., to handle and cut pipe for pipe laying and for joining of the pipe. B. Prior to installing the foundation, trenches shall have all water moved and all work performed in a dry trench. C. All pipes, fittings or specials which are to be installed in the open trench excavation shall be properly bedded in, and uniformly supported on pipe foundations of the various types specified in Section 02225, Trenching, and shown on the Contract Drawings. D. Flat -bottom trenches of required width shall be excavated to the necessary depth as required and maintained in accordance with Section 02225, Trenching. E. Bedding material shall be spread in maximum of 8 -inch layers for the pipe foundation and each layer shall be compacted until the required total depth of bedding has been built up. F. Suitable holes or depressions shall be provided in the pipe bedding to permit adequate bedding of bells, couplings or similar pipe projections. Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02732-5 SANITARY SEWER PIPING G. Compaction methods include hand tamping with T -bars, flat heads, shovel slicing, as well as mechanical compactors. H. The Contractor shall perform his bedding operations with care to maintain line and grade. 3.03. LINES AND GRADES A. The Contractor shall furnish all labor, materials, surveying instruments, and tools to establish and maintain all lines and grades. The Contractor shall have personnel on duty or on standby call, at all times, who are qualified to set and check grades of sewers and manholes as they are installed. B. Easements, property lines, manholes and pipe centerlines necessary for locating the work as well as elevations used in the design of the work are shown on the Drawings. Bench marks are shown on the drawings or the contractor will be provided a list of bench marks. C. The Contractor shall use this information to set line and use laser equipment to set line and grade. The Contractor shall check the grade of pipe by use of level instrument and rod at not more than 50 -foot intervals. D. The use of string levels, hand levels, carpenter's levels or other crude devices for transferring grade or setting pipe are not permitted. E. During construction, the Contractor shall provide the Engineer, when requested, all reasonable and necessary materials, opportunities, and assistance for setting stakes and making measurements, including the furnishing of one or two rodmen or chainmen as needed at intermittent times. F. The Contractor shall carefully preserve bench marks, reference points and stakes, established by the Engineer or Owner, and in case of willful or careless destruction by his own operations he will be charged with the resulting expense to re-establish such destroyed control data and shall be responsible for any mistakes or delay that may be caused by the unnecessary loss or disturbance of such control data. 3.04. TOLERANCES A. Pipes shall be laid to the lines and grades shown on the Drawings. B. Pipes shall be straight between manholes or between points of connection to structures or existing pipes. C. The grade of the sewer between manholes and from pipe length to pipe length shall not vary from the design grade shown on the Contract Drawings by more than 0.15 times the design grade, unless a change in grade has been ordered by the Engineer, in which case the same tolerance shall apply. D. Invert elevations at any location shall not vary from the design elevations by more than 0.05 feet, unless a change in invert elevation has been ordered by the Engineer, in which case the same tolerance shall apply. E. Any sewer grade or invert elevation which exceeds these tolerances shall be corrected by the Contractor at his own expense in a manner prescribed, and to the extent ordered, by the Engineer. 3.05. INSTALLATION Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02732-6 SANITARY SEWER PIPING A. The Contractor shall furnish slings, straps, and/or approved devices to provide satisfactory support of the pipe when it is lifted. Transportation from storage areas to the trench shall be restricted to operations which can cause no damaged to the pipe or lining or castings. B. The pipe shall not be dropped from trucks onto the ground or into the trench. C. Pipe laying shall proceed upgrade with spigot ends pointing in the direction of flow. D. Each pipe section shall be placed into position in the trench on the pipe bedding in such a manner and by such means required to cause no injury to the pipe, persons, or to any property. E. The pipe fittings and specials shall be firmly bedded in the pipe foundation so that the pipe barrel is uniformly supported and graded throughout its length. F. Blocking will not be permitted under the pipe, except where the pipe is to be installed in concrete encasement or concrete cradle. G. Holes and depressions in the pipe foundation shall be provided to receive bells, couplings, or similar projections to assure proper bedding of the pipe barrel. H. When the pipe is in proper position, it shall be joined or coupled to the mating end of the previously laid pipe, using the required joint and, the manufacturer's recommended assembly procedure. I. After the pipe has been joined, the pipe bedding material to be placed and spread in maximum 8 -inch layers to the midpoint of the pipe. J. Each layer shall be compacted using mechanical compactors, hand tamping with T -bars, and shovel slicing so that pipe barrel is firmly embedded in the pipe bedding material. K. If inspection of the pipe indicates that the pipe has been properly installed as determined by the Engineer, the Contractor may then continue to spread the pipe foundation material to 12 - inches over the top of the pipe. L. The pipe foundation above the midpoint of the pipe shall be spread and compacted in 12 -inch layers to 12 inches above the top of the pipe. M. When PVC or polyethylene pipe is used, do not compact directly over pipe until the depth of backfill has reached 2 feet above the top of the pipe. N. After completing the pipe foundation to 12 inches above the top of pipe the Contractor may then backfill the remainder of the trench in accordance with Sections 02225, Trenching and 02228, Compaction and the typical trench details shown on the drawings. O. At the end of each day's work or at intervals of length at the option of the Engineer, the Engineer, with the Contractor, will check the grade and inspect the pipe for alignment with lamps or mirrors. Defective work shall be dug up and reinstalled to the satisfaction of the Engineer. P. The completed assembly of pipe sections shall form a sewer with uniform slope. Q. Manufactured pipe plugs or temporary bulkheads shall be placed in the open ends of sewer lines whenever pipe laying is stopped overnight, over weekends, or whenever dirt or debris could enter the pipeline during construction. 3.06. CONNECTION TO EXISTING STRUCTURES Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02732-7 SANITARY SEWER PIPING A. Where sewers are to be connected to existing manholes, or other structures, and where no stub or opening has been provided for the connection, the Contractor shall cut an opening of minimum diameter through the side wall of the structure for inserting the pipe, at the required location. B. In making connections to existing manholes or structures, care shall be taken to avoid damage to the manhole or structure or allowing debris to enter the pipe lines. Any damage resulting from the Contractor's operations shall be repaired and made good by the Contractor at his own expense. C. After inserting the pipe, the annular space remaining outside the pipe shall be completely filled with an expanding joint sealer (activated oakum or compressed foam) and covered with non -shrinking watertight mortar and such joint made watertight so that leakage of water into the structure is prevented. D. The pipe shall be positioned so that the finished or trimmed end of the pipe is flush with the inside wall surface of the structure. The mortar filler shall be struck off neatly to form a smooth, dense surface flush with the inside wall surface of the structure. E. For PVC, plastic or polyethylene pipe, furnish and install a rubber joint waterstop ring around exterior of pipe or provide a manhole adaptor to make a watertight manhole connection as manufactured by Fernco Type "CMA" adaptor: The General Engineering Co. Type "CT" adaptor, Certain -teed, Johns -Manville, or equal. F. Benchwalls in existing structures shall be altered to form a new trough so the new connection will enter the existing flow channel at a 45 degree angle in the direction of flow. G. Benchwalls to be extended upwards to the top of pipes as shown on Drawings. H. Existing flow to be maintained through manhole or by bypass pumping or piping. 3.07. LEAKAGE TESTING A. All installed sanitary sewer pipe and manholes shall be subject to a leakage test as described in Section 02735, Leakage Tests of Sewers. 3.08. FINAL INSPECTION A. Prior to final inspection, the Contractor shall thoroughly clean all new pipes by flushing with water or other means to remove all dirt, stones, pieces of wood, etc., which may have entered during the construction period. B. Each section of installed sewer between manholes, or structures will be inspected by the Engineer before final acceptance. Such inspection will be visual by traversing the inside of the pipe, by closed circuit television inspection. DVD recordings shall be made available to Owner and Engineer for review. Defective work or materials shall be repaired as directed by the Engineer. C. Deflection tests shall be conducted on plastic pipe (PVC). Deflection gauge mandrel meeting ASTM D3034 and F679 shall be pulled on each run of pipe between manholes. 5% deflection mandrels shall be used for testing. D. The pipe and fittings shall be true to both line and grade, shall show no leaks, shall show no obstruction to flow, shall have no projections of connecting pipe into the line, shall be free from cracks and protruding joint materials, and shall contain no deposits of dirt, debris or other material which will in any way reduce the full cross sectional area of the pipe. Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02732-8 SANITARY SEWER PIPING E. Any section of sewer or drain, or portions thereof, which do not comply with the inspection criteria defined above, shall be promptly corrected or repaired by the Contractor at his own expense. F. Pipe which is cracked or collapsed shall be dug up and replaced with new pipe; pipe which is out of line or grade shall be dug up and re-laid to the correct line and grade. G. Deposits of dirt and debris shall be flushed with water through to the downstream manhole and removed. H. At points of leakage, the pipe shall be dug up and replaced or repaired with approved repair clamp couplings (stainless steel Type 304 with stainless steel bolts and nuts or cast iron coupling with stainless steel bolts and nuts) so as to permanently stop the leak in a manner which shall receive the prior approval of the Engineer. I. All manholes shall be watertight. All joints between precast wall sections, between cast iron frame and brick, and between brick units themselves shall be neat, continuous, and flush with the adjacent surfaces. Dirt and debris shall be removed from all manholes. 3.09. PIPE SCHEDULE LOCATION SIZE TYPE OF PIPE TYPE OF JOINT LINER REMARKS See Contract 8" DIP Class 350 Pushed Joint w/ Mortar w/ Drawings Rubber Gasket Asphaltic Coating See Contract 12" PVC DR 25 Pushed Joint w/ NA Restrain joints where — Drawings Rubber Gasket indicated on drawings See Contract 12" DIP Class 350 Pushed Joint w/ Mortar w/ Restrain joints where Drawings Rubber Gasket Asphaltic indicated on drawings Coating See Contract 16" PVC DR 25 Pushed Joint w/ NA Restrain joints where Drawings Rubber Gasket indicated on drawings See Contract 16" DIP Class 250 Pushed Joint w/ Epoxy Liner Restrain joints where Drawings Rubber Gasket indicated on drawings See Contract 24" DIP Class 250 Pushed Joint w/ Epoxy Liner Restrain joints where Drawings Rubber Gasket indicated on drawings See Contract 24" PVC DR 25 Pushed Joint w/ NA Restrain joints where Drawings Rubber Gasket indicated on drawings END OF SECTION Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02732-9 SANITARY SEWER PIPING SECTION 02735 LEAKAGE TESTS OF SEWERS PART1 GENERAL 1.01. SECTION INCLUDES A. Leakage testing by air pressure methods. B. Manhole vacuum testing. 1.02. RELATED SECTIONS A. Section 02732 - SANITARY SEWER PIPING B. Section 02734 — MANHOLES AND COVERS 1.03. REFERENCES A. Uni-Bell Plastic Pipe Association - UNI -B-6-98 Recommended Practice for Low Pressure Air Testing of Installed Sewer Pipe. Refer to example calculation at end of this Section. B. ASTM 1598 - Standard Test Method for Time -to -Failure of Plastic Pipe under Constant Internal Pressure C. ASTM D2122 - Standard Test Method of Determining Dimensions of Thermoplastic Pipe and Fittings 1.04. SUBMITTALS A. The CONTRACTOR shall submit proposed materials, methods, equipment, and operations regarding cleaning and testing of gravity sanitary sewers to the ENGINEER for approval prior to the start of cleaning and testing operations. 1.05. TEST REQUIREMENTS A. Backfilling of the sewer trench to ground or road surface shall be in place and completed for 30 calendar days or as approved by Engineer, prior to start of testing of each Section of sewer. B. Testing shall be completed prior to final paving and final restoration. C. Low pressure air test shall not exceed drop of 1.0 psig for time period listed in attached Table 02735-1. Test procedure shall conform to ASTM C828 except as modified by the UNI -Bell Plastic Pipe Association Publication UNI -B-6-98, for Low Pressure Air Testing Of Installed Sewer Pipe. Refer to Table 02735-1 for maximum allowable time for a 1.0 psig drop. D. Deflection Test - Maximum deflection 5 percent. Refer to Section 02732 for detail of GO -NO- GO mandrel. E. Maximum test length shall not exceed 1,000 feet. Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02735-1 LEAKAGE TESTS OF SEWERS In the case of sewers laid on steep grades, the length of line to be tested at any one time may be limited by the maximum allowable internal pressure on the pipe and joints at the lower end of the line. The recommendations of the pipe manufacturer shall be followed in this regard. F. The Engineer shall witness all tests. G. Leakage Tests - Replacement of Existing Sewer Systems - Leakage tests shall be performed on new sewer and manholes, replacing existing sewers and manholes, using one of the two methods described as follows: Where existing live sewers and live laterals have been replaced with new piping, leakage tests shall be performed by the above-described methods if (a) the section has no laterals between manholes; (b) can be plugged off without affecting existing connected facilities; and (c) the flow at the upstream manhole can be pumped around the section to be tested. 2. Where the section to be tested has live lateral connections, test methods shall be performed by television inspection and joint testing methods. Where the new piping fails to pass inspection or joint tests, the failed pipe or joint shall be re -excavated and replaced with a permanent repair satisfactory to the Engineer (using chemical sealant to stop leaks in new pipe is not an acceptable method). 1.06. PROJECT RECORD DOCUMENTS A. Submit documents under provisions of Section 01700, Record Documents. B. The following copies of forms for testing are attached to the end of this Section. 1. Low Pressure Air Testing of New Sewers. 2. Table 02735-1, Low Pressure Air Testing of Sewers, including attached Appendix I. Manhole vacuum tests. 1.07. FIELD MEASUREMENTS A. Low Pressure Air Testing Measure length of section to be tested. 2. Measure time interval and pressure drop. 3. Record measurements on GHD Form 169. 1.08. COORDINATION A. Coordinate maintenance of traffic with local authorities. PART PRODUCTS Not used. Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02735-2 LEAKAGE TESTS OF SEWERS PART 3 EXECUTION 3.01. EXAMINATION A. Backfill has been in place the required time before start of test. B. No connections to live sewers or live laterals have been made unless directly replacing existing sewer. 3.02. PREPARATION A. Pipelines and manholes have been flushed and cleaned of all debris, stones, silt, etc. such that all surfaces of pipe and manholes are visible. B. The Contractor shall have on the job all the proper tools, pipe plugs, air bags, gauges, pumps, wires, water trucks, compressors, etc. necessary to properly test the pipe and manholes. 3.03. TESTING A. Low Pressure Air Testing 1. Prior to start of test permanently repair all visible leaks. 2. Isolate each section to be tested with air tight plugs. 3. Low pressure air testing procedures shall conform to ASTM C-828 as modified by UNI -B-6-98. 4. On ductile iron pipe sewer sections, no pressure drop is permitted. 5. On PVC sewers, the maximum allowable drop in pressure from the test pressure shall be 1.0 psig during the minimum holding time. a. Test pressure shall be calculated using the following equation: P = 3.5 + H (psig) 2.31 where: P = Test pressure, maximum of 10 psi H = Height of groundwater above invert 6. All pressurizing equipment used for low-pressure air testing shall include a regulator or relief valve set no higher than 10 psig to avoid over -pressurizing and displacing temporary or permanent plugs. In no case should the starting pressure exceed 10.0 psig. 7. Either mechanical or pneumatic plugs may be used. All plugs shall be designed to resist internal testing pressures without the aid of external bracing or blocking. If pneumatic plugs are utilized, a separate hose shall also be required to inflate the pneumatic plugs from the above ground control panel. Plug the upstream end of the line first to prevent any upstream water from collecting in the test line. This is Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02735-3 LEAKAGE TESTS OF SEWERS particularly important in high groundwater situations. When plugs are being placed, the pipe adjacent to the manhole shall be visually inspected to detect any evidence of shear in the pipe due to differential settlement between the pipe and the manhole. A probable point of leakage is at the junction of the manhole and the pipe, and this fault may be covered by the pipe plug, and thus not revealed by the air test. 8. To facilitate test verification by the Engineer, all air used shall pass through a single, above ground control panel. The above ground air control equipment shall include a shutoff valve, pressure regulating valve, pressure relief valve, input pressure gauge, and a continuous monitoring pressure gauge having a pressure range from 0 to at least 10 psi. The continuous monitoring gauge shall have minimum divisions of 0.10 psi and an accuracy of +0.04 psi. The equipment to include a separate certified test gauge for periodic checking of the accuracy of the basic equipment gauges. 9. Two separate hoses shall be used to: (1) connect the control panel to the sealed line for introducing low-pressure air, and (2) a separate hose connection for constant monitoring of air pressure build-up in the line. Low pressure air shall be slowly introduced into the sealed line until the internal air pressure reaches 4.0 psig greater than the average back pressure of any groundwater above pipe, but not greater than 10.0 psig. After a constant pressure of 4.0 psig is reached, the air supply shall be throttled to maintain that internal pressure for at least 2 minutes or until the temperature of the entering air to equalize with the temperature of the pipe wall. When temperatures have been equalized and the pressure stabilized at 4.0 psig, the air hose from the control panel to the air supply shall be disconnected. 10. The continuous monitoring pressure gauge shall then be observed while the pressure is decreased to no less than 3.5 psig (greater than the average back pressure of any groundwater over the pipe). At a reading of 3.5 psig, timing shall commence with a stop watch or other timing device that is at least 99.8 percent accurate. 11. If the time shown in Table 02735-1 (at the end of this Section) for the designated pipe size and length elapses before the air pressure drops 1.0 psig, the section undergoing test shall have passed the leakage test. The test may be discontinued once the prescribed time has elapsed even though the 1.0 psig drop has not occurred. 12. If the pressure drops 1.0 psig before the appropriate time shown in Table 02735-1 has elapsed, the air loss rate shall be considered excessive and the section of pipe has failed the test. 13. If the section fails to meet the above requirements, the Contractor shall determine at his own expense the source, or sources of leakage, and he shall repair or replace all defective materials and/or workmanship to the satisfaction of the Engineer. The extent and type of repair as well as results, shall be subject to the approval of the Engineer. The completed pipe installation shall then be retested and required to meet the requirements of this test. 14. The times shown in Table 02735-1 are for the length of main sewer tested. For lengths other than those shown, the time to be interpolated. Further, the tables do not have any reduction of time for length of laterals connected to the section of sewer being tested since it normally is not significant. For all precise calculation of time allowance including laterals, refer to UNI -Bell UNI -B-6 publication and the sample calculations and formula shown at the rear of this section. Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02735-4 LEAKAGE TESTS OF SEWERS B. Manhole Vacuum Testing General a. After the manhole has been completely constructed, the frame installed thereon, and the trench backfilled, a vacuum test shall be performed. b. Any damage caused to properties due to sewage handling and/or sewage backup while vacuum testing shall be the responsibility of the Contractor. 2. Vacuum Testing Equipment - Furnish testing equipment as specified in the manufacturer's written instructions. For this procedure, pressure gauge MUST read in inches of mercury, not in psi. Vacuum Test Procedures a. Perform vacuum testing in accordance with the testing equipment manufacturer's written instructions. b. Draw a vacuum of 10 inches of mercury and close the valves. Manhole will be acceptable when vacuum does not drop below 9 inches of mercury for the following manhole sizes and times: 1) 4 -Foot Diameter - 60 seconds. 2) 5 -Foot Diameter - 75 seconds. 3) 6 -Foot Diameter - 90 seconds. Repair or replace defective manholes and retest. 4. If the manhole fails to meet the above testing requirements, the Contractor shall determine, at his own expense, the source(s) of the leakage, and he shall repair or replace all defective materials and/or workmanship to the satisfaction of the Engineer. The extent and type of repair, as well as results, shall be subject to the approval of the Engineer. The completed repairs shall then be retested and required to meet the leakage requirements of this test. Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02735-5 LEAKAGE TESTS OF SEWERS TABLE 02735-1 LOW PRESSURE AIR TESTING OF SEWERS PIPE DIAMETER (INCHES) *SHORTEST TIME (MIN:SEC) LENGTH FOR SHORTEST TIME (FT.) TIME FOR LONGER LENGTH (SEC.) TIME (MIN:SEC) FOR LENGTH (L) SHOWN 100 FT. 150 FT. 200 FT. 250 FT. 300 FT. 350 FT. 4 3:46 597 0.380 L 3:46 3:46 3:46 3:46 3:46 3:46 6 5:40 398 0.855 L 5:40 5:40 5:40 5:40 5:40 5:40 8 7:34 298 1.520 L 7:34 7:34 7:34 7:34 7:36 8:52 10 9:26 239 2.374 L 9:26 9:26 9:26 9:53 11:52 13:51 12 11:20 199 3.418 L 11:20 11:20 11:24 14:15 17:05 19:56 15 14:10 159 5.342 L 14:10 14:10 17:48 22:15 26:42 31:09 18 17:00 133 7.692 L 17:00 19:13 25:38 32:03 38:27 44:52 21 19:50 114 10.470 L 19:50 26:10 34:54 43:37 52:21 61:00 24 22:40 99 13.674 L 22:47 34:11 45:34 56:58 68:22 79:46 27 25:30 88 17.306 L 28:51 43:16 57:41 72:07 86:32 100:57 30 28:20 80 21.366 L 35:37 53:25 71:13 89:02 106:50 124:38 33 31:10 72 25.852 L 43:05 64:38 86:10 107:43 129:16 150:43 36 34:00 66 30.768 L 51:17 76:55 102:34 128:12 153:50 179:29 *Time allowed for 1.0 psig drop in pressure. Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02480-6 LEAKAGE TESTS OF SEWERS ;F['1_tillj)! 1 usrl aroit 17 641:nudA, ISI AI 4,0WA0LF Alf; IDIS HATE Iacefel aewera h.1,■ been a8nassJ: she Best 10.6 EXAMPLE Cl A Q value u(0 We Coble fess pas uuseuie lune &hall The 841.'wnnpu4Ed 40 la:Judr all go 9 Fl+rapllik A wbmik-4c I.1 efoaabuir terlh of pet sgoA14I 9009 6114H be uIII9964 fes a9SL1ae Iala6al Kwdsa 108141g Ilia 1011016•IAS 1`00111101■: JOIN pulpa" of Ilial App4nJtx is au 11lus• 14 Inch pipe Is C! feta 1unF. W. fake Owns# 44 quality plea nia&rrlals. Vsod line 14.4 pauper applicallua of 4141, I41:P+n- sequlfed tsar 9ialir 1..1 is O .i pias worl6n.a&41p, and li1ha jn181t. t,.esded practice wish $alar.$ in appearelele J+uPit 9 1 T EST IrSM9 CAI CULA TION ry •i -0#L • . , to N[ it .1 Aiutr a• 14 Il,u. 10.44. 5 no pit a al. .4 64 S..181n b ($10' 7ahl. 91 no -to Star Al! Iasi 9(.010 mh+ll b1, t'+Frul-646d 1051ssg `-,I,] ►- Pea Tit•7i=l y+ •-.•u�e1.`V ina lot 15.16 ■ vaIis9i of candhlnal which a it S rov pma4bua4 aloe 46 1ptclrl. Ile nli.Is+'a equa11.1a- '"by be 11bc4,waleleJ In Ilia field, Its 7 EXAPLIN gz fess a Itaa H.ni gess 79 fa. . [1K ' F A 1154ti.l41.1 with lame wlialuwra salt T 0 UIS � A neanw1,.t o lls nlanhalc mca,16 f nn fttlaak ■ 34 lucl. pip -Lite. 1lksi nslnirnl.ne Worth: 7 � S11091461 shut, in 14.witals, 0 ta.1r pipe is ISO 1861 lung. 140 lam.$ 54811 apply. Thus, tilt requuccl 1YJmee�: T - ShuAatl Ione, in ■econds, allowed 11-1 Ihs &IN pan- :samr:n.p41 6.186 to Ihs reach. Whet 9s tht sec a 0 S psis pit at -#t de up Poll1 a110..9J fur like 1'i, pees- suit to dt.kei e.0 p818 rsqulted lest Ilene (0s, a 04 pit$ paeeuNa (11 inilwlraanJ ti0ir:nttd,l Sure 464mnr 1-Opdg. {( + 00013$19 (1`111.1 as "a L, • dti,li lo.i E14A1Ir4c c K - 0 kMI10 111., Moe nut lei ■ Ilal&1, bug 1101 be as 8-4"Oln&- Tile required tell Flint aaa be A 411 (oat ataltni of #ansbul Than 10. 99550 1.0, its 1 d64csly final T-6%lt It, Fur )SO feel lower pops has been rr-6ditJ Joe a• Q - 1] f0II cub{: Its I11wh1u0e/ mil I'- Iwcl1 plest. 111E it quit 94 ie sl line■ it A ealal of III fact afnaminal6 1 &quirt (cal of snscrn.l Q � O rasa 4o./sg.1`e. 9. SI 49 lain o;cs and Is accondl]. a$ 1-iping an -:1 1411 fees of analht i' P 1 &s.r12:e. i e l mum al inlrr,lig w+fi:a; 18.31KAUPJLF O lalc.al piping baancl off Of 9%e IS 1,11,.1414141 (•spa d,anrcacs in A 7511 fmi.,e ascl4,a of 000145.1 I I In k Alpe sewer lips- AW Jart+als he-* 6cs• lot beg. and IN asady for [titins. A $alai of 130 lots of ■0d%D& pl..gitJ aaJ a dl be 1.0led 4 !.&+1814 of pine %.list$ lest- 111j,11j). - NiWnLnal dlamearrr of aloe 4 jostle $al ost saws@ pipe Is :a0m;A sc4 so Wilk Slit 95 inch lwafn line. IIIm& ed 1.1 feti- ■rte. dlffeianl sisc piers beim= she 350 flak $*clean and will 45 In.:ludsd pee8110ae ding' .a.licll will be &ern IrltsJ. In ns,► 4951. What will be she +equaled sees pilot What 19 rhe mpps1,•p6149e less _ FDr 40041' 4IN-isnl ieallnl uF Inns evil Ibi s1, far a 5 pe Ig V asusee dr.op? alit peps nrar-ofl;? ace,h•n6 6ndju, Ntttlk.nb of 151ote. ds.neeaer 1-e. Ll, Ita&ptilive Icngltkr 1,.f lilt Sal -jaw- I lasest sswele loans, Cs dlssssutj• S.•fufi+n: All las,oal icw,s ,foga an #'free. a 11119EJ peesune deep all V S peas ear. d+flcf6ns $!be pipe% being Ed rhea 6asec9bls $aid tine■ lice Se:lisn near be dialcgs6dr.i linea @heir gas 0464V be pied les lieu of it's 1 O raiz limotd lisle J. 9 41. 1 hctconse. lbs @aquhrd itst sine will gcnually out 11$016.-401 enough as p116.61N■ J#.qa. ff a O S psis rlerawe dr.q• IN 1-: she Sane as (am kaawlple. A. It., Yntta. camppuNstn lstfra 10 Sanr..m 9 4 mimed. like ■ppl.mpela4& isqui+ed Iia& al-Ikes It slit ss.o.tmpuldd late $k ne Is abuse ennugk e.ikr. and Sg accunds. It roust be Slacks fan a O.5 pail shall ht r1'a:ily fall as It -no al lhae0 011- la ailLow 114 at Ca ion &sped to go os. Hera% tits Nora: if latcNal "Witt lied awl bar• dh• chap. T11e foul let salusnn In Sas 11 rained using Ilafas:itA% afpsas4on floe T earlitill 111-11 lift p14atmn■i41 10 b1, less of ScBa&dmA. Har eequ6■Nd im time woull be vides $ht spriaplless Aitonvle for ailed above. 4c(4Ns anJ varnplg r.l1h Iiia Spec{fka4i+n- Ill anlnutea and 1) lcrondl, it.. Daily 34 Ing Slot Itqulsed Itll Being bec8uet 9.4 TESTIN9114AJN $111WEAI WI■11 Safi SPECIi(FA IrIMI TARkE= &c:o#LdS Iwrsr4. Is 1-06.4, 1166.1 Is.. 116.4 calurwas I.ATE11AL SEW! fIS Ta 14:1114aar 411e ptopse use ami $ties rstnm• 90.4 Ex^"?I E C 159 Iasi, 11 is clean is,rlvcnlcell N+lnauda iAnniiaed snend:d piscikt I.as air 4s&lin6. she follow. W1125 J1P10J4 She «qulled fall $ltnr lee fJr a 8016461 &cw&Ba when feeling aSWtB 111.41■ [no hide's ate plasided. Table I tewlitne 10 pals prta&uet daup In 117 [ca. ..f nun%- T • I 67s 1- - i 671 .S 411 - 1.141t. 114001 initial fewcts- If i•rllil &ewaaa 4,1' Alma 11.4 "Ise d fob l+din"on 11ent&segtali a4 1.1 is usat 1 40.1■ dianulw pip■ b441vrsa aw.a - Included 4s ahs less, 9llelr kwgl9es+n6y ben• 1 O p&Il err -late daup roans E tlrrling Via a. msnhuicel The required Iasi #mend It 1,41$0 at sully W ilynurtd flit COmpmilln$ esg4mjled guts of ■1 stage 1.5 pall gssales $ban life S •isei.tt: The ttlacl arta Isms IS fealty a nils kalca a.rJ :O c. .%A lees 111sles. 11.16 can bs dibble I.tr.use in aiN+rgt beta, pasittaos of 6nV #+uuwd+r&&re ra1.-uliied ler "eine] Table k T66es 4 14 paaelkt. Jtnaeblag time beaw.i.. I.e9.ai, 0s, @Ware abs y.eps'a JaveNa. Table 11 ,anasip, uead 6i:au5s 6 9.0 VSA4 rmesau.c El.or Is - house ea.wra■ wage nunnally 161,•.54" it.. 91.c9lf-14 mnlwlnsusn 4LW146fig qua641d foe ke O-5 mprrlfkd. S11k is 317 1'.it t1..•f9ls 1,l.& 29s, ■a..dly of 81-9 air lama wbenewrr the Bufed eslot prm■au.. d,ar Goin . jr :..... fwm 9-nlll, asa.wiatad Wilk nae ,0in4wun5 .a.r.c..... 46 kill Ilio 615 agn6641 Idea w of as 1-6464 1'.1 pJs i.46,ee than cake 6,449#4 Base sense far on it Jerk psptllne. eke frnsrsl, likes aha loses some of N41leclbw ulaYnnly ba buck p.suure of any Asaundw.me@ •beta sit Italian In Table 1 shalt be used 1k# qu41IV Incesuud &bout 7.1.- Il she legal @salad Sum• Ihs pipe'& invest eauwlats glia required less ahue at fukla..l: f4c& are■ IS gatsles Ilsan 41% Silsbee, feel, JBronllog else laleold Kwela wgll only slislliy T s 8,S109.. 1.11 if 317 r 497 ae:0ndi dde@rabt lest as wemisy of 11.9 $.14, In life evens a 1901 scc4lo$o, fatoing a Thsnfarr, Ihs Requited fes t[nte 1`o+ a 1.0 told udeaslal sulf6rr 2048 1s4a ahue Els pJ$ pIvia usa drop is 497 seconds, as, 4 ►nles- ugU6111 /4141, fill, 90 pabe $he ala 1414 w1s60 Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02480-7 LEAKAGE TESTS OF SEWERS LOW PRESSURE AIR TESTING OF NEW SEWERS Date: _ Project: Contractor: Weather: Job No. Contract No. Section Tested (List Manholes) Length (Feet) Diameter (Inches) Material Time Start/Time Finish Time Interval (Minutes) Air Pressure Initial/Final (psig) Total Pressure Loss (psig) Pass/ Fail to to to to to to to to COMMENTS: WITNESS: OWNER/ENGINEER Name WITNESS: CONTRACTOR Name Title Title Signature Signature Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02480-8 LEAKAGE TESTS OF SEWERS MANHOLE VACUUM TEST Date: _ Project: Contractor: Weather: Job No. Contract No. Manhole No. Inside Diameter (Feet) Required Test Time (Seconds) Initial Vacuum (10 inches) Final Vacuum I Pass/Fail COMMENTS: WITNESS: OWNER/ENGINEER Name WITNESS: CONTRACTOR Name Title Title Signature Signature END OF SECTION Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 02480-9 LEAKAGE TESTS OF SEWERS 0 February 14, 2018 North Carolina Division of Water Resources Public Water Supply Section Plan Review Group Attn: Ms. Shashi Bhatta 512 N. Salisbury Street, Rm. 925S Raleigh, NC 27604 Dear Ms. Bhatta: Reference No. 11123681 Re: Stevens Creek Trunk Sewer Phase 1 — Variance Application: Leakage Test of Sewers Specification Approval Project Name: Stevens Creek Trunk Sewer Coordinates: approximately (35.146,-80.650) GHD Job Number: 11123681 Charlotte Water Project Number: 2017000405 We are working with Christyn Fertenbaugh with the PERCS Unit of NC-DWR on a variance request to utilize PVC as an equal to ductile iron pipe for our gravity sewer project (Stevens Creek Trunk Sewer) located within the Goose Creek Riparian Buffer. As part of this variance, we are requesting approval of our quality testing method specifications for leakage tests of gravity sewers (attached). We are proposing to low pressure air test the sewer main in place of the water pressure test method as specified in the water main standards as found in 15 A NCAC 18C, per 15A NCAC 02T.0305(g)(5). We have found air testing to be an adequate and effective method for leakage testing equal and/or greater to that of water testing methods for low pressure gravity sewer main applications. We are proposing to utilize PVC, AWWA C900 Pressure Class 165 psi, DR25 pipe for this project. As our project is a proposed gravity sewer with generally lower pressures than pressurized water mains, and in utilizing a higher class of PVC pipe than typically required for gravity flow applications, it is our understanding that high pressure hydrostatic testing should not be required. Due to its lower viscosity and surface tension properties, air has been shown to more effectively indicate leaks within pipes. These properties allow air to seep through smaller openings than water which also allows for leakage testing at lower pressures. Understanding the expansive properties of air and the potential for increased dangers versus the use of water, low pressure testing is not to exceed 10 psi as indicated in our specifications. All necessary safety precautions will be taken and have been outlined in our specifications procedure for air testing. In addition to the above mentioned benefits for performing leakage testing with air for our application, due to the location of the proposed sewer alignment through a largely wooded area and large horse pasture, it may be difficult for the contractor to access water sources suitable to perform testing. It may also be difficult for the contractor to de -chlorinate the test water prior to disposal to the environment should it be required. Included with this letter you will find plans, detail and specifications for the proposed project. GHD appreciates your assistance with this project. Please contact me at (704) 342-4913 or Jason.MarshalI@ghd.com if you have any questions or require additional information. OHD ISO 9001 222 South Church Street Suite 400 Charlotte North Carolina 28202 USA -x704 342 4910 F 704 342 4911 W www.ghd.cam Sincerely, GHD Jason Marshall, PE Project Coordinator Encl. Plans Specifications and Details cc: Nicole Bartlett, Charlotte Water Michael Bisignani, GHD Lindsay Matthy, GHD Leakage Test Specification Response Letter - 02.14.2018 (001) Pressure Testing with Air VS. Pressure Testing with Water Pressure testing of water mains and sewage force mains to detect leakage prior to final payment, is common construction practice. The EJP Service Department does pressure tests with either air or water, as required. We are often asked why air testing must be done at lower pressures than with water. The following questions and answers discuss the reasons for lower air test pressures. Question® 150 (lbs./sq. inch) of water pressure equals how many (lbs./sq. inch) of air pressure? Answer 150 (lbs.Aq. inch) of water pressure equals 150 (lbs.Aq. inch) of air pressure. The force experienced on the interior of the pipe is the same for either air or water This would be significant if a pressure test were performed to determine if the pipe had structural integrity, (i.e. will it burst during its ser- vice life?). However, this is not the purpose of a pressure test for leakage. Question: If the forces are the same for both air and water, why should people refuse to test to 150 (lbs./sq. inch) with air? Answer It's very dangerous!!! Unlike water, which is incompressible, air is very compressible, making it hydraulically equivalent to a large mechanical spring. If something were to break or come free during a high pressure air test, the released air could propel an object a great distance with much force. This is why the necessary elimination of trapped air when initially filling pipelines can be so hazardous; air tries to move things to relieve built up pressure; water, because it is incompressible, does not. Question: In finding leaks, why is a low pressure (30-50 lbs./sq. inch) air test as effective as a high pressure (150 lbs./sq. inch) water test? Answer The viscosity and surface tension of water are eachrg eater than that of air Both of these are unique forces that prevent water from escaping through a very small hole, but do not prevent air from escaping from the same small hole. Reasonings: Dynamic Viscosity of Water @ 40 degrees F = 0.0000323 lb. ft. per sq. ft. Dynamic Viscosity of Air @ 40 degrees F = 0.000000363 lb. ft. per sq. ft. So, the viscosity of water is about 89 times greater than the viscosity of air, where... Viscosity is the internal friction of water and makes it resist the tendency to flow, particularly through a small opening Surface Tension of a Water to Air Surface = 0.005 lb. ft./ft. Air has no surface tension (no free surface). Plastic sewer pipelines are typically leakage -tested after installation. The most common method is low-pressure air testing per ASTM F1417 "Installation Acceptance of Plastic Non -Pressure Sewer Lines Using Low -Pressure Air." Since air is a compressible material that expands rapidly if released, safety precautions should be followed. AIR -TEST THRUST FORCES FOR LARGE -DIAMETER PVC SEWER PIPE ASTM F1417 recommends air testing at .. However, the standard calls for increasing the internal test pressure to counteract ex- ternal pressure caused by groundwater above the joint. The maximum internal pressure permitted is 9 psi. The table below provides the thrust forces for large -diameter PVC sewer pipe for pressures in 1 psi increments from 4 to 9 psi. SAFETY GUIDANCE ASTM F1417: The ASTM air -testing standard cautions that measures should be taken to protect personnel. Section 6 provides safety precautions, including the following: Clause 6.1.1: "No one shall be allowed in the manholes during testing." Clause 6.1.3: "When lines are tested, it is mandatory that all the caps and plugs be braced as an added safety factor." Clause 6.1.5: "A regulator or relief valve set no higher than 9 psi shall be included on all pressurizing equipment." Plug Manufacturer's Installation Instructions: The installer of end -plugs should also review and conform to the recommenda- tions of the producer of the plug being used. SAFETY IS PARAMOUNT Although the pressures specified for sewer -pipe air testing are considered low, the resulting thrust forces on a pipeline's end plugs can be substantial. Note: this document discusses low-pressure (maximum 9 psi) air testing for PVC gravity sewer pipes. Under no circumstances should high-pressure air testing be performed on any PVC pipes. Uni-Bell's Handbook of PVC makes this point in section 11.8.3: "Air pressure testing of installed PVC pressure pipe is expressly prohibited for reasons of safety." References: ASTM F679 "Polyvinyl Chloride (PVC) Large -Diameter Plastic Gravity Sewer Pipe and Fittings" (2015); ASTM F1417 "Installation Acceptance of Plastic Non -Pressure Sewer Lines Using Low -Pressure Air," (2011); Handbook ofPVC Pipe, Uni-Bell (2013) 06.13.16 Thrust Force Against Air -Test End -Plug Pipe Size (in) 4 psi 5 psi 6 psi 7 psi 8 psi 9 psi 24 1700 2100 2600 3000 3400 3900 27 2200 2700 3300 3800 4400 4900 30 2900 3600 4300 5000 5700 6400 36 4100 5200 6200 7200 8200 9300 42 5500 6900 8300 9700 11000 12400 48 7200 9000 10800 12600 14400 16200 54 9300 11600 13900 16200 18600 20900 60 10600 13300 15900 18600 21200 23900 SAFETY GUIDANCE ASTM F1417: The ASTM air -testing standard cautions that measures should be taken to protect personnel. Section 6 provides safety precautions, including the following: Clause 6.1.1: "No one shall be allowed in the manholes during testing." Clause 6.1.3: "When lines are tested, it is mandatory that all the caps and plugs be braced as an added safety factor." Clause 6.1.5: "A regulator or relief valve set no higher than 9 psi shall be included on all pressurizing equipment." Plug Manufacturer's Installation Instructions: The installer of end -plugs should also review and conform to the recommenda- tions of the producer of the plug being used. SAFETY IS PARAMOUNT Although the pressures specified for sewer -pipe air testing are considered low, the resulting thrust forces on a pipeline's end plugs can be substantial. Note: this document discusses low-pressure (maximum 9 psi) air testing for PVC gravity sewer pipes. Under no circumstances should high-pressure air testing be performed on any PVC pipes. Uni-Bell's Handbook of PVC makes this point in section 11.8.3: "Air pressure testing of installed PVC pressure pipe is expressly prohibited for reasons of safety." References: ASTM F679 "Polyvinyl Chloride (PVC) Large -Diameter Plastic Gravity Sewer Pipe and Fittings" (2015); ASTM F1417 "Installation Acceptance of Plastic Non -Pressure Sewer Lines Using Low -Pressure Air," (2011); Handbook ofPVC Pipe, Uni-Bell (2013) 06.13.16 Q PVC PI P E Uni-Bell PVC Pipe Association 2711 LBJ Freeway, Suite 1000 Dallas, TX 75234 �r Phone: (972) 243-3902 1 Fax: (972) 243-3907 1 info@uni-bell.org association SECTION 09880 PROTECTIVE COATINGS FOR CONCRETE PART GENERAL 1.01 SECTION INCLUDES A. Multi -coat, chemical resistant, lining system. B. Surface preparation and testing. 1.02 RELATED SECTIONS A. Section 03301 - CONCRETE 1.03 REFERENCES ASTM D638 Standard Test Method for Tensile Properties of Plastics ASTM D695 Standard Test Method for Compressive Properties of Rigid Plastics ASTM D790 Standard Test Methods for Flexural Properties of Unreinforced and Reinforced Plastics and Electrical Insulating Materials ASTM D2240 Standard Test Method for Rubber Property—Durometer Hardness ASTM D4060 Standard Test Method for Abrasion Resistance of Organic Coatings by the Taber Abraser ASTM D7234 Standard Test Method for Pull -Off Adhesion Strength of Coatings on Concrete Using Portable Pull -Off Adhesion Tester 1.04 SYSTEM DESCRIPTION A. On the interior walls of concrete manhole, Contractor shall install a polymer epoxy lining system. The system shall be designed specifically for protection of the concrete surfaces from hydrogen sulfide corrosion. 1.05 SUBMITTALS A. Prior to submittal, provide specification to product manufacturer to review project requirements and to make project -specific product recommendations, if appropriate. B. Product Data - Provide manufacturer's data on specified products, describing physical and performance characteristics. C. Samples - Submit sample, minimum 3 -inch x 3 -inch in size illustrating color and standard finish. D. Manufacturer's Installation Instructions - Indicate required pre–application testing, surface preparation, primer, perimeter conditions requiring special attention, top coat, and total material thicknesses. E. Submit qualifications statement (letter) from manufacturer stating Contractor's training, qualifications, and approved status to install products. G. Submit maintenance information. Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 09851-1 PROTECTIVE COATINGS FOR CONCRETE H. Submit manufacturer's inspection reports for surface preparation. Submit minimum one year manufacturer's warranty. 1.06 QUALIFICATIONS A. Manufacturer - Company specializing in manufacturing the Products specified in this Section with minimum five years' documented experience. B. Applicator - Company specializing in performing the work of this Section with minimum five years' documented experience demonstrating five successful projects and a letter of approval by manufacturer. C. Supervisor - Trained by product manufacturer. 1.07 MANUFACTURER'S REPRESENTATIVE A. Manufacturer shall provide on-site representative to review all installation procedures and to inspect surface preparation. 1.08 DELIVERY, STORAGE, AND HANDLING A. Deliver materials to project site in original, factory -sealed containers or packages labeled with identification of contents, manufacturer's name, address, trademark, date of manufacture, specification number, batch number, color, instructions for use, and recommendations for protective measures against toxicity. B. Materials shall be stored in a dry, enclosed area protected from exposure to moisture. Temperature of storage shall be maintained between 50 degrees F and 75 degrees F. Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 09851-2 PROTECTIVE COATINGS FOR CONCRETE C. Store materials for three days prior to installation in area of installation to achieve temperature stability. 1.09 ENVIRONMENTAL REQUIREMENTS A. Maintain ambient temperature required by manufacturer three days prior to, during, and 24 hours after installation of materials. 1.10 WARRANTY A. Warranty - Include coverage against protective coating delamination from substrate, degradation of surface finish, and spalling. 1.11 MAINTENANCE DATA A. Maintenance Data - Include maintenance procedures, recommended maintenance materials, and procedures for repairing surface. PART2 PRODUCTS 2.01 MANUFACTURERS A. Raven Lining Systems, Broken Arrow, OK. B. Carboline, St. Louis, MO. C. Sauereisen, Inc., Pittsburgh, PA. D. Approved equal. 2.02 LINING SYSTEM A. Raven Lining Systems - Products: Raven 495 epoxy coating system. B. Carboline - Products: Plastie 5371. C. Sauereisen, Inc. - Products: Sewergard Glaze 210GL. Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 09851-3 PROTECTIVE COATINGS FOR CONCRETE PART 3 EXECUTION 3.01 TESTING A. The contractor shall complete the following test prior to application of any coatings. Test results shall be reviewed by the material manufacturer's representative and approved in writing. 1. Moisture Content, ASTM 04263 2. Tensile Strength, ASTM 04541 3. Surface temperature, surface dial thermometer. 3.02 SURFACE PREPARATION A. Concrete surfaces shall be prepared in accordance with manufacturer's instructions and SSPC- SP 13/NACE 6. B. New concrete shall obtain a minimum age of 28 days prior to testing, surface preparation, and application of primer. C. Remove substrate ridges, fins, and other irregularities. D. All concrete surfaces to be coated shall be abrasive blasted to remove weak concrete and surface laitance. Finished surface shall have a texture of medium grit sandpaper. E. At masonry and concrete surfaces, after application of primer, fill bug holes and surface imperfections with a scratch coat epoxy or vinyl ester mortar. 3.03 INSPECTION REPORTS A. Prior to application of coatings the product manufacturer's representative shall inspect surfaces and submit a brief report with required corrections and/or approval. Sewer and manhole installations shall be complete and tested prior to installations of epoxy coatings. 3.04 INSTALLATION A. General - Mix and apply each coat of resinous lining system in compliance with manufacturer's directions to produce a uniform, monolithic surface of specified thickness. B. Apply multi -coats as required to achieve a minimum final thickness of 125 mils. C. Finish to smooth or non -slip level surface without open areas, cracks or voids. D. Follow manufacturer's instructions for application of coatings. 3.05 PROTECTION OF FINISHED WORK A. Barricade area to protect coating until cured. 3.06 QUALITY CONTROL TESTING Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 09851-4 PROTECTIVE COATINGS FOR CONCRETE A. Finished coatings shall be tested in accordance with ASTM D4787 to locate holidays for repair. A minimum of 100 volts per mil of coating thickness shall be used to detect holidays. All holidays and defects shall be repaired according to manufacture instructions. B. Adhesion testing shall be conducted in accordance to ASTM D3359 Method A for evaluation of pull -off strength of coating from substrate. One test shall be performed for every five(5) manholes installed. Test results including procedure, equipment, materials, adhesion values(psi), and photos shall be submitted for evaluation and approval. END OF SECTION Stevens Creek Trunk Sewer Phase 1 Charlotte Water Job No. 7030700047-17-503 09851-5 PROTECTIVE COATINGS FOR CONCRETE Reference No. 11123681 North Carolina #!vision OT 401 & Buffer Permitting Unit Attn: Ms. Christyn Fertenbaugh 512 N. Salisbury Street, Rm. 925S Raleigh, NC 27604 Dear Ms. Fertenbaugh'. Be: Stevens Creek Trunk Sewer Phase 1 — Variance Application: Request for Additional Information EroLect Nam Stevens Creek Trunk Sewer Coordinates: a - - roximately 1135-146 -80.65" GHD Job Number 11123681 Charlotte Water Pro ect Number . 2017000405 i In response to your email dated Friday, January 19, 2018, we have compiled a list of responses and documents requested to complete the review process. On behalf of Charlotte Water, GHD requests your approval for the construction of a sanitary sewer along Stevens Creek and Stevens Creek Tributary, and within the Goose Creek Basin, utilizing PVC, AWWA 0900, Pressure Class 165 psi, DR25 as an equal to ductile iron pipe. There have been no changes in request from the submittal on December 8, 2017 and that includes the use of ductile iron pipe for all stream crossings and for pipe cover depths of greater than 20 --feet as shown on plans. Included with the enclosed variance application, you will find plans, details, and specifications for the proposed project. GHD appreciates your assistance with this project. Please contact me at (704) 342-4913 or Jason. Mars,hall@ghd.com if you have any questions or require additional information. Sincerely, GHD, Jaso Marshall, PE Project Coordinator Encl. Plans Specifications cc: Nicole Bartlett, Charlotte Water Tony Martin, Charlotte Water Chuck Bliss, Charlotte Water Michael Bisignani, GHD 1609001 GHD 222 South Church Street Suite 400 Charlotte North Carolina 28202 USA T7()4 342 4910 F 704 342 4911 w wvvw.ghdxarn Lindsay Matthy, GHD Response to General Comments: DEQ Comment: As the entirety of this project is shown to be constructed within the 200 -foot buffer as required by 15A NCAC 0213, and multiple areas constructed within the 50 -foot buffer, please provide clarification as to what design alternatives were considered to potentially avoid these impacts. Please also provide more information about how the project construction/materials as depicted on the provided plans shall meet the requirements of 15A ICAC 02T.0105(n); and specifically, how they shall provide equal or better protection of the environment in this area. GHD Response: Alternatives outside of the 200 ft buffer zone were evaluated but deemed unfeasible to locate a gravity trunk sewer The trunk sewer project matches the project limits for the Stevens Creek Stream Restoration project being completed by Mecklenburg County Stormwater and Stantec. GHD and Charlotte Water have been working with the stream restoration team to design and construct the proposed alignment with the Stevens Creek and its Tributary stream restoration in order to minimize overall project disturbance. Both of these projects will be bid together and constructed along the same timeline. This will ultimately reduce clearing and minimize disturbance to the overall area. Additionally the alignment was chosen with input from NODE Q's Mooresville office and the project team has held several field meetings and walks with Alan Johnson of NCDEQ for input on the location and disturbance to limit the overall disruption to all stakeholders. Meetings and field visits have also been completed with USACE and US Fish and Wildlife. For requirements of 15A CAC 02T 0 1 05(n), (1) equal or better treatment of the waste-, - P,VC pipe material provides an equal level of service for the conveyance of wastewater. (2) equal or better protection of the waters of the state; and — PVC pipe material produced under A WWA and ASTIR standards is considered an equal to ductile iron pipe produced under similar standards for water and sewer service. Gaskets materials are the same or similar in design and function to provide equal protection for a leak free system. All pipe, no matter the material must pass a zero leakage test to ensure a watertight system. PVC also has the advantage of being inert to corrosion caused by hydrogen sulfide gas. Charlotte Water has experienced corrosion issues with DIP and prefers to utilize PVC for its inert properties, Utilizing PVC eliminates the need for corrosion protection required for DIP sewers providing equal or better protection against leaks and pollution caused by corrosion. (3) no increased potential for nuisance conditions from noise, odor or vermin. — Pipe material does not affect environmental conditions. 2. DEQ Comment: It appears that the alignment of the buffers as shown on the plans (30-, 50-, and 200 -feet) is based on a proposed stream alignment, not the existing alignment. Please provide more information regarding the proposed realignment of the stream, as this affects the buffer zones through which this project is proposed to be constructed, GHD Response: In prior discussions with Alan Johnson from NC DEQ and Mecklenburg County Stormwater, it was determined that utilizing the 50 and 30 foot buffers reflecting the proposed stream restoration alignment was most appropriate, As both projects will be constructed at the same time, the 30 and 50 foot buffers for the proposed stream alignment are most reflective of conditions at the time of post construction. Additionally, in most cases, the proposed stream EMC Variance Response Letter - 02 7.2018 X1%,1,,7 , IFIN, alignment buffers pushes the proposed sewer alignment further from the existing stream top Of bank. a. DEQ Comment: it also appears that the 100 -year flood elevation lines are based on the existing creek alignment rather than the proposed alignment. Please provide more information, as this affects the installation of different manhole -types, per 15A NCAC 02T.0305(e), GHD Response: We are awaiting final base flood models revision reflective of the 100 -year flood elevation for the proposed stream restoration. We are aware of the requirements for either minimum two feet rim elevations above the 100 -year flood line, or watertight lids and vents, We have requested the revised floodplain mapping currently in process for a Conditional Letter of Map Revision and wit] make changes to update manhole types, elevations, and vents as necessary to comply with 15A N CA C 02 T, 0305(e). 3. DEQ Comment: As this project requests the usage of PVC in most locations whereas both the 02T and 026 rules require ductile iron within such a buffer, please provide clarification as to why ductile iron cannot be utilized for this project. GHD Response: We are requesting that PVC be considered as an equal to ductile iron pipe as PVC is preferred to DIP due to its inert corrosion resistant properties. Ductile iron pipe requires special coatings for sewer service and is susceptible to corrosion once liner has deteriorated, 4. DEQ Comment: The provided VAR 10-2013 form indicates that sewer lines located in wetland areas shall have anti -seep collars installed, however, it was not clear where wetland areas are impacted nor where anti -seep collars may be installed. Please clarify, GHD Response: Plans will be updated accordingly to show the anti -seep collars. Where the sewer alignment passes through wetland areas, we have callouts specifying to reduce clearing to 40 feet width in the permanent easement. 'Wetiands are located on sheets 6, 7, and 12 and anti -seep collars have been added to the drawings. Plans/Sp ecif icatio n s: t. DEQ Comment: All plans and specifications submitted for the variance must be signed/sealed by a Professional Engineer licensed to practice in North Carolina, Please revise. GHD Response: Plans and Specifications have been signed and sealed included in this submittal. 2. Brief sections of specifications were provided. Please clarify if these are parts of Charlotte Water's standard specifications, which are referenced by the provided plan sheets. All specifications to be referenced by this variance that are not part of Charlotte Water's standard specifications must be signed/sealed by a Professional Engineer licensed to practice in North Carolina. GHD Response: Technical specifications were provided specific to Stevens Creek Sanitary Trunk Sewer project that incorporate Charlotte Water's standards for materials and construction. Full project specifications have been Signed and Sealed for review. 3. DEQ Comment: Have the quality testing methods for gravity lines outlined in the provided specifications been approved by the Public Water Supply Section — Plan Review Group as being equivalent to water main standards as found in 15A NCAC 18C, per 15A NCAC 02T.0305(g)(5)2 if so, please provide a copy of the letter or email approving the testing methods. If this has not yet been verified, please contact the Plan Review Team Leader Shashi Bhatta at Shashi. Bhatta@ncdenr.gov, EMC VadanCe Response Letter - 02 7.2018 P ,GHD Response: GHD is working with Sashi Bhatta for a resolution and will provide a formal response at a later date. 4. DEQ Comment: It appears that multiple manholes depicted as being located within the current I00 -year flood elevation are listed as having vented covers (e.g. H-17, 19, 20, 24, 25), All manholes located within the 100 -year flood elevation must have a watertight seal, per 15A NCAC 02T.0305(e). Please revise such that all manholes located within the 100 -year flood elevation are depicted as having watertight covers and frames, and ensure that the manhole schedule located on plan sheet 2 correctly reflects which type of manhole cover shall be installed, GHD Response: See previous response and general comments 2.a. Manholes with vented cover located inside the 1007year floodplain have rim elevations well above (at least 2 feet) 100 -year floodplain elevations. All manholes are pending further revisions pending flood study analysis. Please note General Comment #2, as it appears that in many locations, the location of the 100 -year flood elevation may change significantly if the stream is realigned as shown on the plans. See previous response and general comments 2.a. 5. DEQ Comment: On plan sheets 9 and 11, a temporary stream crossing is depicted. Please clarify if these tributary streams shall permanently cross the sanitary sewer after construction is completed, and if so, please revise such that these sections of sewer are constructed of DIP as the provided VAR 10-2013 form for variance requests to the 15A NCAC 02B rules indicates that ductile iron shall be used for all stream crossings. GHD Response: These intermittent tributaries crossings have been revised to include DIP at the crossings. Please see plans included in this submittal. 6. DEQ Comment: On plan sheet 14, the distance between MH -28 and MH -29 appears to be greater than 425 linear feet (measured at approximately 465 linear feet). Per 15A NCAC 02T.0305(i)(2), please provide documentation from Charlotte Water indicating that they have the capability to provide routine cleaning and maintenance on the sewer at the specified manhole separation, GHD Response, - Charlotte Water has the capabilities to clean sewers beyond 500' and we have verified with their Operations and Maintenance staff. Please see email communication between Charlotte Water, Project Manager, Tony Martin and operations staff Lee William, See enclosures. EMC; Variance Response Letter -02.7.2098 L From: Jason Marshall <)ason]ManhaU@ghdzmm/ Sent: Wednesday, February 28,20l83:39PM To: 8hatta.Sbashi Cc -Lindsay K4atthy;Fenenbaugh.ChristynL ^ RE: [External] FW: Additional Information for Stevens Creek Variance W[S Shashi, Thanks you foryour response and I hope the following will address any concern or issues to be resolved. Our specification for sewer references C908which references C605 and K823 and Charlotte Water will only accept materials and installations that meet all applicable industry standards. Below is a clipped image from JM Eagle's product brochure for PVC pipe. All applicable standards are listed on the cut sheet and this is typical of what we would look for during our shop drawing review, VVe reference UNI -Bell for our testing standard |oour specification df So I would like to address DWQ!s concerns and also want to be certain that the issue is over leakage concerns,is this correct? | was looking back at some other project specifications for local projects on Brier and McAlpine Creek both mention ezero leakage inthe testing specification.SpecificaN Brier states ° Passing the joint air test shaHnot preclude required tan��rdiszero rejection fthe xvnrkifgromndxvaterin��n*tinnsubsequently nccuoatthe joint, Th The s e �|eakage.".'Vou|dadding language 10our specification thattheaOowab|e|eakageisOgaHonsforbnthpipeandnanholes help meet the requirements? Wecould also add imaddiion to passing the air test that there should bemnvisible leakage or mowing water observed in the pipe and invert. Infiltration testing and add or additional air testing and repairs vvVu|d be required prior tofinal acceptance inthese situations occur. We can update the specifications to address and send over for review if acceptable? Please let meknow if there is anything else I can do to address any concerns for our resubmittal to Christyn. ~ ~ ^ -/^� �u~-L' �� Thanks, �������)J�' ,�c�ui�w\�� `�c� �~�wc� ( »rV /����"&����� �~_~~~ ^ `~~1/ , -- ~ Jason ZI z- % XNN T E, Assembly Mark I.D., Inside Danneter El : Distan between Ist Insertion/ 0,D,: Outside Diameter. Assembly Mark to the end of spigot, T.: Wall Thickness E2: 0iistance between 2nd Insertion/ 0`1: Bell Outside) Diameter Assernbly Mark to the end of spigot, Pipe Compound: ASTM D! 784 Cells Class 12454 Gasket: ASTM F477 Integral Bell joint: ASTM D3139 Certifications: ANSI/NSF Standard 61 1� UL Standard 1285 Pipe Length: 20 feet (+/- 1 ") laying length, AWWA C605 Installation.- JIVI EagleInstallation Guide -1 ev i s ed 1, 2 01,_ T his s in10rm n ,iia, , V$� From: 13hatta, Shashi Imailto:shashi.bhatta@ncdenr.gov] Sent: Wednesday, February 28, 2018 2:03 PM To: Jason Marshall <Jason. M a rsha ll@ghd.com> Cc: Lindsay Matthy <Lindsay. Matthy@ghd.com>; Fertenbaugh, Christyn L <christyn.fertenbaugh@ncdenr.gov>; l3hatta, Shashi <shashi.bhatta@ncdenr.gov> Subject: RE: [External] FW: Additional Information for Stevens Creek Variance WCS Hello Mr. Marshall, I understand the difficulties with applying the water main testing standards for sanitary sewer lines. Therefore; I do not have a definite answer as to if the sanitary sewer testing procedure that you proposed would be equal to the water main testing procedure.,, Since the issue is to reduce the potential of leaking sanitary sewer lines, I recommend focusing on installing PVC sewer lines with less joints (or no joints if possible, e.g. HDPE), and making sure the joints and PVC sewer lines are installed as specified in AWWA C605 and AWWA Manual M23. I hope this helps. -I also had a discussion with Christyn about your proposal just a few minutes ago. Thanks. Shashi \jex-�-(:�crA as V a Uf Vi G VVeVet—j S ru Oak \\A-aJe"CX1Vta 'or& -s "a4cy- riicun sitAn&acc§s From, Jason Marshall [rnailto:Jason.Marshalf@gh(J.coi-n] F J LA.�tt V.X— 4V\�, YYAOS�— (�eUttvCLUr4— Sent: Tuesday, February 27, 2018 4:27 PM 4` To: To: Bhatta, Shashi <shashi.bhatta@ncdenr-gov> Oao-) Cc: Lindsay Matthy <Lindsay.Matthy@ghd.com>; Fertenbaugh, Christyn L <christyn.fertenbailg�_@ELdenr.gov> Subject., RE: [External] FW: Additional Information for Stevens Creek Variance WCS Thanks and see my responses below, Jason Sent:_gilltoshashi -YJ 2018 3:46 PM — Tuesday, February 27, 0hat1u To: Jason Fer��nbau�h Chr�YnL ' Cc: dndsayK0�thy<^ Shashi |mfornmationforStevensCreekVmrianceVvCS [External] RE: ic^,u�.� ...: Additional posing? Same standard bell and spigot with gaskets utilized for water Hello Mr, ��arshaU,xvhottype ofjoints are you pro ins See page 4ofproduct b/ochurefor typical joints web _df is i i �o heinsta|\edvvithdirectional drillingnd cover construction. Havegravity service by conventional cut anot specified HDPE for gravity service, other than pipe bursting,HDD contractors are using it for pressure lines but I would needinput. Charlotte Water had issues getting contractors to bid on anto spea w t con ot as familiar with the material and installation. I have read throughHDPE water main�becau:se local contractors are n e proposed would be considered "equal" tothe proposal but need a little more time. I will let you know if what you havwater main standard tomorrow. I still need to review some AWWA standards and manuals to decide. Thanks. dt/filesJBlue-Rrute__ --p Shashi Sent: Tuesday, February 27, 2018 11:09 AM To Vnana Snus/» nbau�h �hr�\ynL Cc: Undsuym«am'Y~ mnfor Stevens Creek Variance V«C) Subject: FW: [External] FW: Additional Shashi, Have you had achance tmlook over the eo�ai|7lmehave our res pmnselo[hr�tynFer��uh�u�hreadyamdvvouk�Uketo send in our response to haveyou/connmemtsaddressed-Qdmenmisevvecam�atethatyourcomme,'p�.`p=.....",-�_ the other comments. Please let meknow ifthere isanything you need. Jason From: Jason Marshall Sent: Thursday, February l5,2O18l1:l3AKX 3 Cc: Fertenbaugh, Christyn L <christyn.fertenbaugb �a Matthy��d.c�orn @ncdenr.go >; Lindsay Matthy <.Lindsa > Subject: RE: [External] FW: Additional Information for Stevens Creek Variance WCS Shashi, A map of the project area is attached for reference, Figure 5. No water mains are present at this location just gravity sewer and there are no conflicts with separation between water and sewer. We are installing DIP under creeks but the buffer rules for this area state that DIP be used at all locations per 15A NCAC 02B.0607, Page 5. We are requesting a variance for the approval of PVC for al:l areas other than creek crossings. I've also attached our permit letter for the original request. The reason for the deviation is that Charlotte Water prefers PVC over DIP for sewer due to corrosion issues. PVC is also easier to work with and we believe the rules may have been written at a time when PVC was less robust and there were issues with quality. Let me know if you have any further questions. Thanks Jason From: Bhatta, Shashi mailto:shashi.bhatta,@,n.cdenr.go Sent: Thursday, February 15, 2018 9:55 AM To: Jason Marshall <Jason. Marsha ll@?ghd.com> Cc: Fertenbaugh, Christyn L <christvn.ferten.baugh@ncdenr.go >; Lindsay Matthy <Lindsay.Matthy@ghd.com> Subject: RE: [External] FW: Additional Information for Stevens Creek Variance WCS Hello Mr, Marshall, can you please provide additional information on this before I can provide an answer? is there a water main proposed at this location that does not meet the separation requirements of the Rules Governing Public Water Systems, Section .0906? or is itjust a sewer line project under a creek and you are proposing to install PVC line instead of DIP? What is the reason for the deviation? Thanks. Shashi ShasKm. Fhqtt-a, P.F. PZapi. Review 7-eaku ","der public water siqp1gSection. ,r)ZvZsiok,i, of wqterresoarces 1634 meqiZ service cektter, Raleigh, mr, 2�6_yq-26-34 Epnaii r-orrespokidexze to atLd front tK-- address is s"Yeet to the North r—qrOzzPta 7>1'(Wo Records Lawqk,�d nca be disclosed to third Parties. From: Jason Marshall LTailtojason -Marshal I@ghd corn] Sent: Wednesday, February 14,ZO18S:2OPK8 To: Bhatta, Shashi Cc: Fedcnbaugh,[hrbtynL >; Lindsay Ma1Whv > Subject: [External] FW: Additional Information for Stevens Creek Variance VV[6 Shashi, GHD is working on a variance application and have been asked to respond to the comment highlighted below from Christyn Fertenbaugh. I've attached a letter and specification to address this comment and request your approval as part of our variance application. If you have any questions or comments please let me know and we will work to address them. I appreciate your assistance. From- Fertcnbaugh,ChristynL Sent: Friday, January 1A,Z0184:S1PM To: Jason Marshall Cc: Higgins, Karen Subject: Additional Information for Stevens Creek Variance WCS Hello, VVehave reviewed the variance request regarding the Stevens Creek Trunk Sewer Phase 1,with avariance needed for construction utilizing PVC within a stream buffer. In accordance with the provisions of 15A NCAC 02T01056dfor alternative design criteria, please provide the following information: General Comments: As the entirety of this project is shown to be constructed within the 200 -foot buffer as required by 15A NCAC U2B,and multiple areas constructed within the S&-fuotbuffer, please provide clarification astuwhat design alternatives were considered to potentially avoid these impacts. Please also provide more information about how the project construction/materials as depicted on the provided plans shall meet the requirements of 15A NCAC 02TO105(n); and specifically, how they shall provide equal or better protection of the environment in this area. Itappears that the alignment of the buffers as shown omthe plans (30 -,S0 -, and 200 -feet) is based on proposed stream alignment, not the existing alignment. Please provide more information regarding the proposed realignment of the stream, as this affects the buffer zones through which this project is proposed to be constructed. a. It also appears that the 100 -year flood elevation lines are based on the existing creek alignment rather than the proposed alignment. Please provide more information, as this affects the installation of different manhole -types, per 15A NCACO2TO305(e). 3. As this project requests the usage of PVC in most locations whereas both the 02Tand 02B rules require ductile 4. The provided VAR 10-2013 form indicates that sewer lines located in wetland areas shall have anti -seep on|lao installed, however, it was not clear where wetland areas are impacted nor where anti -seep collars may be installed. Please clarify. I. All plans and specifications -submitted for the variance must hesigned/sealed 6naPnofessiona|EnQinee/|ioensed topractice in North Carolina. Please revise. 2. Brief sections of specifications were provided. Please clarify if these are parts of Charlotte Water's standard specifications, which are referenced by the provided plan sheets. All specifications to be referenced by this variance that are not part of Charlotte Water's standard specifications must be signed/sealed by a Professional Engineer licensed tnpractice inNorth Carolina. 3. Have the quality testing methods for gravity lines outlined in the provided specifications been approved by the Public Water Supply Section — Plan Review Group asbeing equivalent to water main standards asfound ln15A NCAC 18C, per 15A NCAC 02TO305(g)(5)? if so, please provide a copy of the letter or email approving the testing methods. If this has not yet been verified, please contact the Plan Review Team Leader Shashi Bhatta at . 4. It appears that multiple manholes depicted as being located within the current 100 -year flood elevation are listed as having vented covers (e.g. IMH'17, 19, 20, 24, 25)./\U manholes located within the 100'yearflood elevation must have awatertight sca|,per 1SAN[A[Q2T.O3O564.Please revise such that all manholes located within the 100-yearflood elevation are depicted as having watertight covers and frames, and ensure that the manhole schedule located on plan sheet 2 correctly reflects which type of manhole cover shall be installed. a. Please note General Comment #2, asitappears that inmany locations, the location ofthe 100'yemr flood elevation may change significantly if the stream is realigned as shown on the plans. S. Unplan sheets 9 and 11,atemporary stream crossing bdepicted. Please clarify if these tributary streams shall permanently cross the sanitary sewer after construction bcomp|eted,andifs4p{easems/isexuchthatihexe sections of sewer are constructed of DIP as the provided VAR 10-2013 form for variance requests to the 15A NCAC 02B rules indicates that ductile iron shall be used for all stream crossings, 6` On plan sheet 14, the distance between MH -28 and MH -29 appears to be greater than 425 linear feet (measured at approximately 465 linear feet). Per 15A NCAC 02T.0305N(2), please provide documentation from Charlotte Water indicating that they have the capability to provide routine cleaning and maintenance on the sewer at the specified manhole separation. If you have any questions, please let me know. Thanks! ChristynL Fertenbaugh, P.E. Environmental Engineer PERCS Unit Division ufWater Resources Department ofEnvironmental Quality 3l8-8O7-6312—Office 919-807-6489 — Fax K4aiUuK: 1617Mail Service Center Raleigh, NC27699-1617 Physical: SIZN.Salisbury Street, Rm. 925l Raleigh, NC 27604'1170