Loading...
HomeMy WebLinkAboutNCG550261_Inspection_20141212United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN I 2 15 I 3 I NCG550261 111 12 I 14/12/11 I17 18 I S J 19 L G] 201 I 211111 1 1 I I I I II I I I I I I I I I I I I 1 I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 671 70 I I 71 I I 72 I r I u ty 73 � 74 75I I I I I I I I80 I I Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 01:00PM 14/12/11 13/08/01 885 Mills Gap Road 885 Mills Gap Rd Exit Time/Date Permit Expiration Date Fletcher NC 28732 01:20PM 14/12/11 18/07/31 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Billy J Cromer,885 Mills Gap Rd Fletcher INC 28732//704-684-4550/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit 0 Operations & Maintenance 0 Effluent/Receiving Waters Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Andrew W Moore ARO WQ//828-296-4684/ Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type (Cont.) NCG550261 I11 121 14/12/11 117 18 ICI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) At the time of the inspection, the current homeowners John and Michelle Schmidt were unaware of the wastewater discharge system serving their home. Ms. Schmidt and I discussed the system and the maintenance requirements. To properly maintain the system, and to bring the system into compliance with the permit, the owners should: 1) Complete and submit the enclosed Change of Ownership form, 2) Have the septic tank checked and pumped if the solids level is found to be more than 1/3 of the liquid depth in any compartment, 3) Purchase wastewater chlorine tabs and caps for the chlorination tubes, 4) and find, and maintain access to, the effluent pipe. Page# Permit: NCG550261 Inspection Date: 12/11/2014 Owner - Facility: 885 Mills Gap Road Inspection Type: Compliance Evaluation Operations & Maintenance Is the plant generally clean with acceptable housekeeping? Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit (If the present permit expires in 6 months or less). Has the permittee submitted a new application? Is the facility as described in the permit? # Are there any special conditions for the permit? Is access to the plant site restricted to the general public? Is the inspector granted access to all areas for inspection? Comment: Disinfection -Tablet Are tablet chlorinators operational? Are the tablets the proper size and type? Number of tubes in use? Yes No NA NE ■ ❑ ❑ ❑ ❑ ❑ ■ ❑ Yes No NA NE ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ ❑ ❑ ■ ❑ ■ ❑ ❑ ❑ Yes No NA NE ■ ❑ ❑ ❑ ❑ ■ ❑ ❑ 2 Is the level of chlorine residual acceptable? ❑ ❑ 0 ❑ Is the contact chamber free of growth, or sludge buildup? E ❑ ❑ ❑ Is there chlorine residual prior to de -chlorination? ❑ ❑ 0 ❑ Comment: No tablets were observed in the chlorination tubes, nor were there caps for the chlorination tubes. Chlorination tablets must be placed within the tubes for the system to effectively treat the wastewater prior to discharge. Make sure the chlorination tablets are certified for wastewater use. Wastewater tablets are not the same as those used for swimming pools. The permittee should purchase caps for the chlorination tubes. Septic Tank (If pumps are used) Is an audible and visual alarm operational? ❑ ❑ 0 ❑ Is septic tank pumped on a schedule? ❑ 0 ❑ ❑ Are pumps or syphons operating properly? ❑ ❑ 0 ❑ Are high and low water alarms operating properly? ❑ ❑ 0 ❑ Comment: The septic tank should be pumped out every five years or when the solids level is found to be more than 1/3 of the liquid depth in any compartment, whichever is greater. Records of the septic tank pumping events should be kept for future compliance inspections. Page# 3 Permit: NCG550261 Inspection Date: 12/11/2014 Owner - Facility: 885 Mills Gap Road Inspection Type: Compliance Evaluation Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? ❑ 0 ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? E ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? ❑ ❑ 0 ❑ Comment: The effluent pipe was not located. The permittee should locate, and maintain access to, the effluent pipe. Page# 4