Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
820358_Inspection_20181211
wisYoriW,Water �O�D�.vasioi°ofS'o�Land Water�Gonservahon� � °"'�� ''' Type of Visit: 70utine iance Inspection Operation Review 0 Structure Evaluation 0 Technical Assistance Reason for Visit: 0 Complaint 0 Follow-up 0 Referral 0 Emergency 0 Other 0 Denied Access Date of Visit: _]ry / �j� Arrival Time: } 0 Departure Time: I Ti c?ja County: '&Jce e— Region: / 4 Farm Name: �' %�, �,<, S0 Owner Email: Owner Name: �� % �� Phone: Mailing Address: Physical Address: Facility Contact: A - � - I I--y— '0 Title: Onsite Representative: Certified Operator: [�) - a Back-up Operator: Location of Farm: Latitude: Phone: Integrator: Certification Number: %(�s 7 J O Certification Number: Longitude: Design Current D esi n'r "Cu entCurren g;., g *�{ Capac ty Popt V�?et Poultry �Capacztyr Prop Cattle Capacafy *Pop ' 6 iSw ne' Layer 14 Non Layer 5 ') 4 .; 4 es�gn ,Current t `.) t �D;ry7P,ou�tty tCa �aciy iP`o ; , : zr t®ether , �� Other ` Y 1 �M .....:..:_, _.A.�9,....._a,..._ _...........__a:..:n...�...vre.....: ._.. u.....:_r.,.S.. .::: w..� '.. .....».. �: . _.. ......i......:»....«..c.aa.�.. �s ., s,.._.._... ....4+. Wean to Finish Wean to Feeder c Feeder to Finish Farrow to Wean t� �,.;� Farrow to Feeder Farrow to Finish Gilts Boars Discharges and Stream Imuacts � Layers Non -Layers � Pullets Turkeys ;1 h Turkey Poults ' s Other Dairy Cow � Dairy Calf � Dairy Heifer D Cow } � Non -Dairy Beef Stocker � Beef Feeder � Beef Brood Cow 1. Is any discharge observed from any part of the operation? ❑ Yes 0 No ❑ NA ❑ NE Discharge originated at, ❑ Structure ❑ Application Field ❑ Other: a. Was the conveyance man-made? ❑ Yes [-]No [ NA ❑ NE b. Did the discharge reach waters of the State? (If yes, notify DWR) ❑ Yes ❑ No F3/NA ❑ NE c. What is the estimated volume that reached waters of the State (gallons)? d. Does the discharge bypass the waste management system? (If yes, notify DWR) ❑ Yes ❑ No ❑DNA ❑ NE 2. Is there evidence of a past discharge from any part of the operation? ❑ Yes ❑/No ❑ NA ❑ NE 3. Were there any observable adverse impacts or potential adverse impacts to the waters ❑ Yes [ No ❑ NA ❑ NE of the State other than from a discharge? Page 1 of 3 21412015 Continued Facility Number: jDate of Inspection: IG Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? ❑ Yes a. If yes, is waste level into the structural freeboard? ❑ Yes Structure 1 Structure 2 Structure 3 Structure 4 Identifier: Spillway?: Designed Freeboard (in): Observed Freeboard (in): 5. Are there any immediate threats to the integrity of any of the structures observed? (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a waste management or closure plan? Structure 5 ©>e'❑ NA ❑ NE ❑ No 1A ❑ NE Structure 6 ❑ Yes MNo ❑ NA ❑ NE ❑ Yes E] No ❑ NA ❑ NE If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental t reat, notify DWR 7. Do any of the structures need maintenance or improvement? ❑ Yes n No ❑ NA ❑ NE 8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes �o ❑ NA ❑ NE (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require ❑ Yes No ❑ NA ❑ NE maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ Yes El"No ❑ NA ❑ NE maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes ® No ❑ NA ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12. Crop Type(s): 1Z e-r�u"A ❑ NE 13. Soil Type(s): ueel 4,A 14. Do the receiving crops differ from those designated in the CA ? ❑ Yes ❑ ❑ NA ❑ NE 15. Does the receiving crop and/or land application site need improvement? ❑ Yes 0 No ❑ NA ❑ NE 16. Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes JD'N—o ❑ NA ❑ NE acres determination? 17. Does the facility lack adequate acreage for land application? ❑ Yes [<o ❑ NA ❑ NE 18. Is there a lack of properly operating waste application equipment? ❑ Yes io ❑ NA ❑ NE Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes ff 'No ❑ NA ❑ NE 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes �'No ❑ NA ❑ NE the appropriate box. ❑ WUP ❑ Checklists []Design ❑ Maps ❑ Lease Agreements ❑ Other: 21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes [5No ❑ NA ❑ NE ❑ Waste Application ❑Weekly Freeboard ❑Waste Analysis ❑Soil Analysis ❑Waste Transfers ❑Weather Code ❑ Rainfall ❑ Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections ❑ Sludge Survey 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes u o ❑ NA ❑ NE 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes No ❑ NA ❑ NE Page 2 of 3 21412015 Continued Facility Number: k - 7[ate of Inspection: 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes ❑ No 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check [:]Yes ❑ No the appropriate box(es) below. ❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail provide documentation of an actively certified operator in charge? ❑ Yes ❑ No 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? ❑ Yes [—]No Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? 34. Does the facility require a follow-up visit by the same agency? ❑ NA ❑ NE ❑NA ONE ❑NA ❑NE ❑NA ❑NE ❑ Yes ❑ No ❑ NA ❑ NE ❑Yes ❑No ❑NA ❑NE ❑ Yes ❑ No ❑ NA ❑ NE ❑ Yes ❑ No ❑ NA ❑ NE ❑ Yes ❑ No ❑ NA ❑ NE ❑ Yes ❑ No ❑ NA ❑ NE ❑ Yes [:]No ❑ NA ❑ NE cccvicwciiiu��ccwi ivauic. v.. - • •�. - - - Reviewer/Inspector Signature: Date: Page 3 of 3 f 21412015