Loading...
HomeMy WebLinkAboutWQ0041517_Application_20200303DWR Division of Water Resources KtUtivr-u DEQIDVVR State of North Carolina Department of Environmental Quality Al U 0 i 2020 Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Bladen Community Services, LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other 3. Signature authority's name: Gardner Altman. Jr. per 15A NCAC 02T .0106(b) Title: Secretary of Bladen Community Services, LLC 4. Applicant's mailing address: 601 W. Rosemary Street, Unit 1001, City: Chapel Hill State: NC Zip: 27516-. 5. Applicant's contact information: Phone number: (404) 200-8343 Email Address: ghair n chair-pa.com IL PROJECT INFORMATION: 1. Project name: Emereau Charter School Sanitary Sewer and Lift Station 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: WQ0040765 and issued date: 4/4/2019 If new construction but part of a master plan, provide the existing permit number: W000_ 3. County where project is located: Bladen 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.599677' Longitude:-78.5727330 5. Parcel ID (if applicable): 41069 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. Professional Engineer: Larry F. Graham License Number: NC 11602 Firm: Environmental En ingt eerinQ Services Mailing address: PO Box 426 City: Aberdeen State: NC Zip: 28315- Phone number: 910 944-1648 Email Address: larryizraham54@a.tunail.com IV. WASTEWATER TREATMENT FACILITY (WWTF) INFORMATION: 1. Facility Name: Town of Elizabethtown W WTP Owner Name: Town of Elizabethtown Permit Number: NCO026671 V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than W WTF): 1. Permit Number(s): WQCS00154 Downstream (Receiving) Sewer Size: 8 inch System Wide Collection System Permit Number(s) (if applicable): WQCS00154 Owner Name(s): Town of Elizabethtown FORM: FTA 04-16 Pagel of 5 VI. GENERAL REQUIREMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes []No ®N/A 2. If the Applicant is a Developer of lots to be sold, has a Developer's Operational Agreement (FORM: DE V) been attached? ❑ Yes ❑No ®N/A 3. If the Applicant is a Home/Property Owners' Association, has an Operational Agreement FORM: HOA) been attached? ❑ Yes [-]No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ❑ Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ❑ Retail with food preparation/service ❑ Hotel and/or Motels ® School / preschool / day care ❑ Medical / dental / veterinary facilities ❑ Swimming Pool /Clubhouse ❑ Food and drink facilities ❑ Church ❑ Swimming Pool/Filter Backwash ❑ Businesses / offices / factories ❑ Nursing Home ❑ Other (Explain in Attachment) 5. Nature of wastewater: 100 % Domestic/Commercial % Commercial _ % Industrial (See 15A NCAC 02T .0103(20)) "Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Hasa flow reduction been approved under 15A NCAC 02T .0114(f) ❑ Yes ® No ➢ If yes, provide a cony of flow reduction aooroval letter 7. Summarize wastewater generated by project: Establishment Type (see 02T.0114(fl) Daily Design Flow',b No. of Units Flow Charter School, Eventually Grades 1-12 10 gal/student/day 875 8750 GPD gall GPD gal/ GPD gal/ GPD gal/ GPD gal/ GPD Total 8710 GPD a See 15A NCAC 02T .0114(b), (d), (e)(1) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses; public access facilities located near high public use areas; and residential property located south or east ofthe Atlantic Intracoastal Waterway to be used as vacation rentals as defined in G.S. 42A-4). b Per 15A NCAC 02T .0114(c), design flow rates for establishments not identified [in table 15A NCAC 02T.01141 shall be determined using available flow data, water using fixtures, occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 8750 GPD (per 15A NCAC 02T .0114) ➢ Do not include future flows or previously permitted allocations If permitted flow is zero, indicate why: ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number: ❑ Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain): FORM: FTA 04-16 Page 2 of 5 VH. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & MDC (Gravity Sewers): 1. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material 8 1325 PVC ➢ Section II & III of the MDC for Permitting of Gravity Sewers contains information related to design criteria ➢ Section III contains information related to minimum slopes for gravity sewer(s) ➢ Oversizing lines to meet minimum slope requirement is not allowed and a violation of the WC VIH. PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC (Pump Stations/Force Mains): COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: PS # 1 2. Approximate Coordinates (Decimal Degrees): Latitude: 34.600368' Longitude:-78.573862' 3. Design flow of the pump station: 0.00875 millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): 85 gallons per minute at 49 feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length (feet) Material 3 1490 PVC 6. Power reliability in accordance with 15A NCAC 02T .0305(h)(1): ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T .0305(h)(1)(B) ➢ Required for all pump stations with an average daily flow greater than or equal to 15,000 gallons per day ➢ Must be permanent to facility Or if the pump station has an average daily flow less than 15,000 gallons per day: ® Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(I)(C): ➢ It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timeframes, shall be provided in the case of a multiple station power outage. FORM: FTA 04-16 Page 3 of 5 IX. SETBACKS & SEPARATIONS — (02B .0200 & 15A NCAC 02T .0305(f)): 1. Does the project comply with all separations found in 15A NCAC 02T .0305(fl & (g) ➢ 15A NCAC 02T.0305(f) contains minimum separations that shall be provided for sewer systems: Setback Parameter* Separation Required Storm sewers and other utilities not listed below vertical 24 inches Water mains vertical -water over sewer including in benched trenches 18 inches Water mains(horizontal) 10 feet Reclaimed water lines vertical - reclaimed over sewer 18 inches Reclaimed water lines(horizontal - reclaimed over sewer 2 feet **Any private or public water supply source, including any wells, WS-I waters of Class I or Class II impounded reservoirs used as a source of drinking water 100 feet "Waters classified WS (except WS-1 or WS-V), B, SA, ORW, HQW, or SB from normal high water or tide elevation and wetlands see item DI.2 50 feet **Any other stream, lake, impoundment, or ground water lowering and surface drainage ditches 10 feet Any building foundation 5 feet Any basement 10 feet Top slope of embankment or cuts of 2 feet or more vertical height 10 feet Drainage systems and interceptor drains 5 feet Any swimming pools 10 feet Final earth grade vertical 36 inches ➢ 15A NCAC 02T.0305(g) contains alternatives where separations in 02T.0305(fl cannot be achieved. ➢ **Stream classifications can be identified using the Division's NC Surface Water Classifications webpage ➢ If noncompliance with 02T.0305( or (). see Section X of this application 2. Does the project comply with separation requirements for wetlands? (50 feet of separation) ®Yes []No [—]N/A ➢ See the Division's draft separation requirements for situations where separation cannot be meet ➢ No variance is required if the alternative design criteria specified is utilized in design and construction ➢ As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per 15A NCAC 02B .0200? ® Yes ❑ No ❑ N/A ➢ This would include Trout Buffered Streams per 15A NCAC 2B.0202 4. Does the project require coverage/authorization under a 404 Nationwide or [—]Yes ® No individual permits or 401 Water Quality Certifications? ➢ Information can be obtained from the 401 & Buffer Permitting Branch 5. Does project comply with 15A NCAC 02T.0105(c)(6) (additional permits/certifications)? ❑ Yes ® No Per 15A NCAC 02T.0 I 05(c)(6), directly related environmental permits or certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent on issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). 6. Does this project include any sewer collection lines that are deemed "high -priority?" Per 15A NCAC 02T.0402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is subject to erosion that undermines or deteriorates the sewer. ❑ Yes ® No ❑ N/A ➢ If yes, include an attachment with details for each line, including type (aerial line, size, material, and location). High priority lines shall be inspected by the permittee or its representative at least once every six -months and inspections documented per 15A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. FORM: FTA 04-16 Page 4 of 5 EA CERTIFICATIONS: A. Does the submitted system comply with ISA DiCiIC 0sT, the t9ininuur Desiu Criteria for ite. 'yrmiaiu_o ur�;t>;;_aiion gnri F;Forcivi ups triGes_'&rsion�, and the Gatiits. > l-c, 6_:nire�un pesi.r�i C- It:a ilat�st �I �t�n.i, as applicable? 0 Yes ❑ No If No, complete and submit the Variance/AlWmative Design Request application (VADC 10.14) and supporting documents for review. Anoroval of the request is required prior to submittal of the Fast Track Application and supporting documents. 2. Profssional Engineer's Certification: �.rah_am,.__PE—._,_— ___-_---..-- --- —attest that this application for (Professional Engineer's name from Application Item Ill. I.) Emereau Charter School Sanitary Sewer & Lift Station ^,as been reviewed by the and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest that to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version). Although other professionals may have developed certain portions ofthis submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and havejudged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215.6A and 143-215.613, any person who knowingly makes any faise statement, representation, or certification in any application package shall be guilty of a Cl misde ea 'h' r may include a line not to exceed $10,000, as well as civil penalties up to $25,000 per v' ... 0111 North Carolina Professional Engineer's seal, signature, and date: ,�00.� .-....:_ lei. SEAL 11602 3. Applicant's Certification per 15A NCAC 02T .0106(b): 1, _ Gardner Altman,__._Jr.—Secretary _ attest that this application for nature Authorit 's name & title fro t A pjication Item 13.) Emereau (SiNarter Sebool Lift Spta�ion has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments are not included. this application package is subject to being returned as incomplete. 1 understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — in accordance with General Statutes 1 ± 115.6A and 143-2i j;t13; any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor. which ntay include a fine not to exceed $10.000 as well as civil penalties up to $25,000 per violation. Signature:. / r4_�- Date:. /.'N�rldn.,�.,i�27...Li.7.d FORM: FTA 04-16 Page 5 of 5 EQ/DWR ENVIRONMENTAL ENGINEERING SER P.O. Box 426, Aberdeen, N.C. 28315 Phone: 910-944-1648 Fax: 910-944-1652 Email`U., FOO r, u lim P,or l(' - February 28, 2020 Mr. Trent Allen, Environmental Regional Supervisor c/o NCDENR-DEQ 225 Green Street, Suite 714 Fayetteville, N.C. 28301-5094 Re: Sanitary Sewer Lift Station Permit Modification Request for the Emereau Charter School at 995 Airport Road in Elizabethtown, NC. Bladen County. Existing Permit Number WQ0040765 (issued 4/4/2019). Dear Mr. Allen, As you may recall, the Emereau Charter School (ECS) in Elizabethtown is permitted to install a new sewage lift station for 1,200 students with a cafeteria and gymnasium. The contractor to do the work has been selected and we are working toward breaking ground soon. The school management and their General Contractor (GC) have been talking with me about the new lift station size and their anticipated growth. As with any school that is growing, there will be a growth curve, which means it will be several years before the final 1,200 enrollment number is achieved and it may be over 5 years before a cafeteria and gym are built. Emereau currently has 475 students enrolled. There will be several other phases of classroom construction that must take before any cafeteria or gymnasium are built. It is not known exactly when or if the 1,200-student enrollment will be achieved. According to estimated projections, the school plans not to exceed 875 students for another 3 to 5 years. The permit we have from your office includes the design for the 1,200 students plus a cafeteria and a gymnasium. To better match the infrastructure growth plans, we would like to modify the existing permit to reflect an enrollment of 875 students and NO cafeteria and NO gymnasium. Per our phone conversations, I am sending you this letter to summarize the changes we would like to make based on the new enrollment values mentioned above. I feel like this letter is needed to outline our thinking and to specify why the modifications are being requested. Please keep in mind that the basic intent of the lift station at ECS has not changed, but some of the needed hardware has changed. I will outline those major changes below. New drawings and specifications have been developed by EES and these will be furnished to the contractor as soon as we receive your OK. My correspondence to you includes: • The revised executed permit application form FTA 04-16, titled "FAST TRACK SEWER SYSTEM EXTENSION APPLICATION". I am sending you the revised original and a copy of the permit application. • One $480 check from Bladen Community Services, LLC who is the owner of the property. The check is made out to NCDEQ. I have attached a copy of the check to the permit application copy. Of course, an original and one copy of this letter. Revised Sewage Flow Estimates. As you know, the construction of a sewage lift station based on a student population that is 4 to 6 years away can be costly and underutilized for years. The Emereau Directors have reconsidered their projections and wish to size the tank more in line with enrollment projections for the next few years. A student population of 875 is now being considered a target value from a design standpoint. Therefore, I have redesigned the lift station for the 875 students using sewage flow data outlined in "WASTE NOT DISCHARGED TO SURFACE WATERS" Subchapter 15A NCAC 02T, Section .0300 "Sewer Extensions", by the N.C. Department of Environmental Quality (DEQ), Division of Water Resources (DWR) Section .0114 (c). Seethe revised projected flows in Table 1. TABLE 1 Summa of Future Sew a a Flow Volumes at ECS Item Flow Per Number of Daily Flows Using a Future Student Students for the Enrollment of 875 Students Modified Design School Days Only) Unadjusted sewage flows 15A 10 gpd / 875 students 8,750 gals. per day NCAC 02T - Section .0114 c . student Sewage Flow Estimates with a Peaking Factor Added. According to the document titled "Minimum Design Criteria for the Permitting of Pump Stations and Force Mains", a peaking factor for populations served by pump stations is shown in Equation 1, but in no case shall the peaking factor for hourly flows be less than 2.5. PF = (18+ �P)/(4+4P) (Equation 1) Where: PF = Peaking Factor P = service population in thousands PF = (18+�0.875)/(4+q0.875) = (18+0.9354)/(4+0.9354) = 3.84 Schools produce most of their wastewater during regular school hours. Flows usually begin around 7 AM and diminish significantly after about 3 PM. Typically by 5 PM sewage flows stop. There will be some evening and weekend use of water from athletic events, school productions, and community meetings, but typically these sewage additions do not exceed school day peaks. Table 2 looks at calculating a peak one -hour flow based on typical school day flows. TABLE 2 Summary of Peak Flow Rates at ECS Assuming 875 Students Item Flow Per Student Unadjusted sewage flows 15A NCAC 02T - Section .0114 c . 8,750 gallons per day Average hourly flow assuming the typical hours of school operation is from 7 AM to 5 PM or 9 hours 972 gallons per hour 16.2 gallons per minute Calculated Peaking Factor for maximum hourly water production 3.84 Calculated Maximum estimated sewage production per hour 3,732 gallons per hour 62.2 gallons per minute Chosen pump -out capacity for the Lift Station 85 gallons per minute In the engineer's opinion, a Peaking Factor of 3.84 is high for a typical school, so the engineer used a flow simulation program to help in sizing the new lift station. This program uses typical sewage generation values throughout the school day, realizing that higher water use will take place around the lunch hour. Since time -of -day use was taken into consideration, the engineer used a peaking factor of 2.5 during the highest water use hour. Based on that simulation, a pump capable of pumping 85 gallons per minute is more than sufficient to manage even peak flows at the school while leaving a large emergency storage capacity in the tank. More will be said about emergency storage volumes below. Proposed Changes to the Lift Station Tank. The lift station itself has been changed to a cylindrical configuration. We believe this configuration will help with installation. In addition, it will afford us some extra emergency water storage volume. The plan is to use a 10 ft. diameter cylindrical concrete precast tank with an internal height of 18 feet. We plan to leave the 85 gpm duplex pumps in place. The full volume of this tank will be at least 10,575 gallons. Based on numerous simulations, the emergency storage in this tank with an 875- student enrollment is almost a full day of predicted water use at the school. Until enrollment reaches 875 students, there will be more than a day's sewage generation available for emergency storage. As I have mentioned to you before, my experience shows that seldom do sewage flows from schools without cafeterias or gyms use 10 gpd/student. Hopefully after 4 or 5 years of operation we will have more accurate flow data from the school and can re-evaluate the lift station details at that time. Proposed Changes to the Emergency Power Equipment. In our original pen -nit request, we estimated the sewage flows to exceed 15,000 gpd using 02T values for schools. Now that we have reduced the student enrollment to 875 and removed the gymnasium and cafeteria from the mix, the average daily flow will be 8,750 gallons. This means we no longer need a permanent standby electrical generator. Since we will have a day or more of emergency storage in the new tank, the threat of overflows is not of great concern. I have included a quick connection electrical coupler for a portable generator should the need arise. I might also mention that I have added a quick connection for a portable sewage pump if that would become necessary. All -in -all removing the generator is prudent as long as the Emereau flows remain below 15,000 gpd. Summary. In summary, the revisions for the ECS sewage lift station are: • Change the predicted enrollment to 875 students and to eliminate the addition of a gymnasium and cafeteria. Projected average daily flows are now at 8,750 gallons. • Flow simulations with peaking factors added demonstrate an emergency storage volume in the new tank design to be at least one day at an average flow of 8,750 gallons. • Change the configuration of the concrete tank to a cylindrical model with more emergency storage volume. The new tank would have a 10 ft. internal diameter and have an internal height of 18 feet and contain around 10,575 gallons. • To eliminate the need for a permanent standby electrical generator at the lift station. A portable generator connection will be added so the system can be operated via this power source. • Most of the other basic infrastructure for the new lift station has remained the same as stated in the original permit. • This permit revision does not propose any changes to the upstream sanitary sewer components as designed by Anderson Engineering & Associates. • The installation contractor will be provided a complete copy of the new drawings and specifications as mentioned above. Once your office is OK with these revisions and gives us the green light to proceed, I will coordinate with everyone to get revised plans out and hold pre -construction meetings. Duties, responsibilities, questions, etc. will be handled at the pre -construction conference. When the system is finally installed, I will send you and all concerned my certification of completeness. In order to meet construction deadlines, we will need to begin construction ASAP, so please do not hesitate to get back to me with any questions or needs. I will also be happy to furnish you with copies of the revised plans upon your request. On behalf of Emereau Charter School, Bladen Community Services, LLC, and Anderson Engineering & Associates, I want to thank you for your timely review of this project. Please let me know if you have any questions. Best Enclosures Cc: GardnerAlhnan Larry Anderson Trey Greer Chad DeVane F. GrW=, P.E. mmental Engineering Services 4 t6t1Vt3! ���,� State of North Carolina Department of Environmental Quality vl a-f 0 3 2020 Division of Water Resources 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources 1°ROS FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DwR) AR items must be completed or the application will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Bladen Community Services. LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other ctL-fLA:: 'v(<® b 3. Signature authority's name: Gardner Altman. Jr. per 15A NCAC 02T .0106(b) ty' P ) DEQiDVVR Title: Secretary of Bladen Community Services, LLC 10 A it 0 3 V7P 4. Applicant's mailing address: 601 W. Rosemary Street. Unit 1001, City: Chapel Hill State: NC Zip: 27516-_ 5. Applicant's contact information: Vhf 6�E.011-HC= Phone number: (404) 200-8343 Email Address: ghairaa ehaina.com IL PROJECT INFORMATION: 1. Project name: Emereau Charter School Sanitary Sewer and Lift Station 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W00040765 and issued date: 4/4/2019 If new construction but part of a master plan, provide the existing permit number: WQ00_ 3. County where project is located: Bladen 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.5996770 Longitude:-78.572733' 5. Parcel ID (if applicable): 41069 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: • •__.-=--- ` --._r n_..,.1..,,,,. T -1 h mher NC 11602 M44V 41t1...; CIIIIGrC�/i�% TO NCDEQ THE C/O LARRY GRAHAM ENV ENGINEERING ORDER PO BOX 426 OF ABERDEEN, NC 28315-0426 12837 1i111111hilruld1111i11111111Piiilllllllllrgllllulmdih . uw�wa wmen 480.00 �t1@§tiprla Ta ., 19/530 BILL PAYMENT ;,OQ000OJ1rJ291 B Mard02 N20 N.A. 0110001 k012837 DOCLAR- Void After 189. DAYS. Signafure Gan file This check has been authorized , by Your depositor, rvT vi. a 5 tutivtu DEQ '� State of North Carolina VVR Department of Environmental Quality 'ei Ax 0 3 2020 Division of Water Resources '' 15A NCAC 02T .0300 — FAST TRACK SEWER SYSTEM EXTENSION APPLICATION Division of Water Resources FTA 04-16 & SUPPORTING DOCUMENTATION Application Number: (to be completed by DWR) All items must be comuleted or the anolication will be returned I. APPLICANT INFORMATION: 1. Applicant's name: Bladen Community Services. LLC (company, municipality, HOA, utility, etc.) 2. Applicant type: ❑ Individual ® Corporation ❑ General Partnership ❑ Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ❑ Other V �arF aN;T t c, � it,J- 3. Signature authority's name: Gardner Altman. Jr. per 15A NCAC 02T .0106fb) -;) /,h �� OTEC Title: Secretof Bladen Community Services, LLC ary 4. Applicant's mailing address: 601 W. Rosemary Street. Unit 1001, 4 .Zd o24 City: Chanel Hill State: NC Zip: 27516-_ 5. Applicant's contact information:� rn i3 t" t � ` Phone number: 404 200-8343 Email Address: &ajr@ghajr-pa.com IL PROJECT INFORMATION: 1. Project name: Emereau Charter School Sanitary Sewer and Lift Station 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project If a modification, provide the existing permit number: W00040765 and issued date: 4/4/2019 If new construction but part of a master plan, provide the existing permit number: WQ00_ 3. County where project is located: Bladen 4. Approximate Coordinates (Decimal Degrees): Latitude: 34.5996770 Longitude:-78.572733° 5. Parcel ID (if applicable): 41069 (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: t;—.. Numherc NC 11602 rui vi. r r1 DIr O"iDiiVOR TT PLEA SE POST THIS PAYMENT FOR OUR,MUTUALCUSTOMER Accotar�t: - EMER�AU .. .. •� ., •`i 480.00 Please Rinact ADy Qrlestions Ta ; 19/530 (856) 739 M6 ,ONLINE BANKING BILLPAYMENT" I1LApE COMb1UNITy $EIiS(ICES, LLC VA I NVALLEYETh.O2, - QOOOOOSI ST ATGy�NTAI C+A E� A3LANTA 020 " `; ., ?• BANK OF AMFRICA; N.A. ,• 120 7379032 012849 62849 0001/0001 k012837 i Pay FOUR HUNDRED EIGHTY AND 00/100------------------,---........... DOLLARS TO NCDEQ $ 1 ,. THE C/O LARRY GRAHAM ENV ENGINEERING Void After T80'DAYS. ! ORDER PO BOX 426 OF ABERDEEN, NC 28315-0426 12837 &gnatbke,On F* • IIII'IIIIIIII'IIIII'I'll'II"II'IIIIIIII'II'I'I'II"Iill'IIIIIIII This check has 4eenatlthorizetl by your dgposftnr i Permit Number WQ0041517 Central Files: APS _ SWP 3/4/2020 Permit Tracking Slip Program Category Status Project Type Non -discharge Active New Project Permit Type Version Permit Classification Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions 1.00 Individual Primary Reviewer Permit Contact Affiliation stephanie.zorio Coastal SWRule Permitted Flow 8,750 Facility Facility Name Major/Minor Region Emereau Charter School Sanitary Sewer and Lift Station Minor Fayetteville Location Address County Bladen Facility Contact Affiliation Owner Owner Name Owner Type Bladen Community Services LLC Non -Government Owner Affiliation Gardner Altman Jr. 601 W Rosemary St Dates/Events - Chapel Hill NC 27516 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 3/4/2020 3/3/2020 3/4/2020 3/4/2020 Regulated Activities Requested /Received Events Wastewater collection Additional information requested Additional information received Quffall Waterbody Name Streamindex Number Current Class Subbasin Permit Number WQ0041517 Program Category Non -discharge Permit Type Gravity Sewer Extension, Pump Stations, & Pressure Sewer Extensions Primary Reviewer stephanie.zorio Coastal SWRUle Permitted Flow 8,750 Facility Facility Name Emereau Charter School Sanitary Sewer and Lift Station Location Address Owner Owner Name Bladen Community Services LLC Central Files: APS _ SWP 3/4/2020 Permit Tracking Slip Status Project Type Active New Project Version Permit Classification 1.00 Individual Permit Contact Affiliation Major/Minor Region Minor Fayetteville County Bladen Facility Contact Affiliation Owner Type Non -Government Owner Affiliation Gardner Altman Jr. 601 W Rosemary St Dates/Events Chapel Hill NC 27516 Scheduled Orig Issue App Received Draft Initiated Issuance Public Notice Issue Effective Expiration 3/4/2020 3/3/2020 3/4/2020 3/4/2020 Regulated Activities Requested /Received Events Wastewater collection Additional information requested Additional information received Curtail Waterbody Name Streamindex Number Current Class Subbasin