Loading...
HomeMy WebLinkAboutNCS000115_DMR_20200221 Date: February 20,2020 Novozymes,NA Inc. 77 Perry's Chapel Church Rd. novozymese Franklinton,N.C. 27525 Rethink Tomorrow NCDEQ Division Of Water Quality RECEIVED 1617 Mail Service Center Raleigh,N.C.27699-1617 Attn:Division Of Water Quality MAR 0 5 2020 DENR-LAND QUALITY STORMWATER PERMITTING Storm Water Sampling, NPDES Permit No.NCS000115J Dear Sir/Madam, During review of storm water sampling results,it was observed that there was a slight exceeded benchmark in Biochemical Oxygen Demand(BOD)from our Outfall 2 location. Upon immediate investigation,per Tier One requirements,it was discovered that although during sample event no signs of potential issues were present,in the area approximately 20 yards from where samples are collected the combination of filtration systems not being properly maintained/serviced and the off-loading of raw materials,specifically sugar,are considered causes of the recent exceedance of BOD.Plans are in place to have personnel begin with cleaning filtration systems and more caution taken place while material is being handled. Also,due to storms during previous week,high winds were probable cause of material being blown into grass areas near Outfall 2. Continued monitoring by Environmental Services Department will take place in order to prevent future exceeded benchmarks in Biological Oxygen Demand (BOD) from Outfall 2. Kind Regard e6A1 Joe Ladd Environmental Compliance Coordinator Environmental Services r STORMWATER DISCHARGE OUTFALL(SDO) MONITORING REPORT Permit Number NCS 000115 SAMPLES COLLECTED DURING CALENDAR YEAR: 2020 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) FACILITY NAME Novozymes, NA Inc. COUNTY Franklin PERSON COLLECTING SAMPLE(S) Joe Ladd PHONE NO.(919 )494-3000 CERTIFIED LABORATORY(S) Enco Labs Lab# Lab# SIGNATURE OF PERMITTEE OR DESIGNEE REQUIRED ON PAGE 2. Part A: Specific Monitoring Requirements Outfall Date 50050 No. Sample Total Total pH HOD COD TSS Collected Flow(if app.) Rainfall mo/dd/yr MG inches 1 2/11/2020 .25" 7.0 3.3 22 83 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month?Oyes @no (if yes,complete Part B) Part B:Vehicle Maintenance Activity Monitoring Requirements Outfall Date 50050 00556 00530 00400 No. Sample Total Flow Total Oil&Grease Non-polar Total pH New Motor Collected (if applicable) Rainfall (if appl.) O&G/TPH Suspended Oil Usage (Method 1664 Solids SGT-HEM),if appl. mo/dd/yr MG inches mg/I mg/1 unit gal/mo Form SWU-247,last revised 6/12/2015 Page 1 of 2 f -. STORM EVENT CHARACTERISTICS: Mail Original and one copy to: Division of Energy Mineral and Land Resources Date 2/11/20 Attn:Central Files Total Event Precipitation(inches): .25" 1617 Mail Service Center Event Duration(hours): (only if applicable—see permit.) Raleigh,North Carolina 27699-1617 (if more than one storm event was sampled) Date Total Event Precipitation(inches): Event Duration(hours): (only if applicable—see permit.) "I certify,under penalty of law,that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information,the information submitted is,to the best of my knowledge and belief,true,accurate,and complete. I am aware that there are significant penalties for submitting false information, including the possibi' of fine d imprisonment for knowing violations." / . ' / 2/20/2020 (Signature of Per ee)A (Date) • Form SWU-247,last revised 6/12/2015 Page 2 of 2 STORMWATER DISCHARGE OUTFALL(SDO) MONITORING REPORT Permit Number NCS 000115 SAMPLES COLLECTED DURING CALENDAR YEAR: 2020 (This monitoring report shall be received by the Division no later than 30 days from the date the facility receives the sampling results from the laboratory.) FACILITY NAME Novozymes, NA Inc. COUNTY Franklin PERSON COLLECTING SAMPLE(S) Joe Ladd PHONE NO.(919 )494-3000 CERTIFIED LABORATORY(S) Enco Labs Lab# Lab# SIGNATURE OF PERMITTEE OR DESIGNEE REQUIRED ON PAGE 2. Part A:Specific Monitoring Requirements Outfall Date 50050 No. Sample Total Total pH BOD COD TSS Collected Flow(if app.) Rainfall mo/dd/yr MG inches 2 2/11/2020 .25" 7.3 34 67 14 Does this facility perform Vehicle Maintenance Activities using more than 55 gallons of new motor oil per month?Oyes @no (if yes,complete Part B) Part B:Vehicle Maintenance Activity Monitoring Requirements Outfall Date 50050 00556 00530 00400 No. Sample Total Flow Total Oil&Grease Non-polar Total pH New Motor Collected (if applicable) Rainfall (if appl.) O&G/TPH Suspended Oil Usage (Method 1664 Solids SGT-HEM),if appl. mo/dd/yr MG inches mg/I mg/1 unit gal/mo Form SWU-247,last revised 6/12/2015 Page 1 of 2 STORM EVENT CHARACTERISTICS: Mail Original and one copy to: Division of Energy Mineral and Land Resources Date 2/11/20 Attn:Central Files Total Event Precipitation(inches): .25" 1617 Mail Service Center Event Duration(hours): (only if applicable—see permit.) Raleigh,North Carolina 27699-1617 (if more than one storm event was sampled) Date Total Event Precipitation(inches): Event Duration(hours): (only if applicable—see permit.) "I certify,under penalty of law,that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based on my inquiry of the person or persons who manage the system,or those persons directly responsible for gathering the information,the information submitted is,to the best of my knowledge and belief,true,accurate,and complete. I am aware that there are significant penalties for submitting false information, including the possib' ity of fines d imprisonment for knowing violations." a:Ae f 2/20/2020 (Signature of Pei-puttee) (Date) Form SWU-247,last revised 6/12/2015 Page 2 of 2 ENCO Laboratories Accurate. Timely. Responsive. Innovative. 102-A Woodwinds Industrial Court Cary NC,27511 Phone: 919.467.3090 FAX: 919.467.3515 Tuesday, February 18, 2020 Novozymes North America (N0008) Attn: Joe Ladd 77 Perry Chapel Church Road Franklinton, NC 27525 RE: Laboratory Results for Project Number: [none], Project Name/Desc: Stormwater Testing ENCO Workorder(s):CD01285 Dear Joe Ladd, Enclosed is a copy of your laboratory report for test samples received by our laboratory on Tuesday, February 11, 2020. Unless otherwise noted in an attached project narrative,all samples were received in acceptable condition and processed in accordance with the referenced methods/procedures. Results for these procedures apply only to the samples as submitted. The analytical results contained in this report are in compliance with NELAC standards, except as noted in the project narrative if applicable. This report shall not be reproduced except in full,without the written approval of the Laboratory. This report contains only those analyses performed by Environmental Conservation Laboratories. Unless otherwise noted,all analyses were performed at ENCO Cary. Data from outside organizations will be reported under separate cover. If you have any questions or require further information, please do not hesitate to contact me. Sincerely, Aijb( Chuck Smith Project Manager Enclosure(s) FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 1 of 8 Q_o www.encolabs.com SAMPLE SUMMARY/LABORATORY CHRONICLE Client ID: Outfall 1 Lab ID: CD01285-01 Sampled: 02/11/20 09:45 Received: 02/11/20 16:07 Parameter Preparation Hold Date/Time(s1 Preo Date/Time(sl Analysis Date/Time(s1 SM 2540D-2011 NO PREP 02/18/20 02/13/20 09:29 02/13/20 09:29 SM 5210 B-2011 NO PREP 02/13/20 09:45 02/12/20 10:40 02/12/20 10:40 SM 52200-2011 Same 03/10/20 02/17/20 12:06 02/17/20 15:45 Client ID: Outfall 2 Lab ID: CD01285-02 Sampled: 02/11/20 10:15 Received: 02/11/20 16:07 Parameter Preparation Hold Date/Time(s1 prep Date/Time(s1 Analysis Date/Time(s1 SM 25400-2011 NO PREP 02/18/20 02/13/20 09:29 02/13/20 09:29 SM 5210 B-2011 NO PREP 02/13/20 10:15 02/12/20 10:40 02/12/20 10:40 SM 52200-2011 Same 03/10/20 02/17/20 12:06 02/17/20 15:45 FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 2 of 8 ( 1 " 'CIO) www.encolabs.com SAMPLE DETECTION SUMMARY Client ID: Outfall 1 Lab ID: CD01285-01 AlielAs Resuly4 Flaq MIX P L ruAta Method Notes Biochemical Oxygen Demand 3.3 2.0 2.0 mg/L SM 5210 B-2011 Chemical Oxygen Demand 22 10 10 mg/L SM 5220D-2011 Total Suspended Solids 83 25 25 mg/L SM 2540D-2011 Client ID: Outfall 2 Lab ID: CD01285-02 Analvte Results Flaq MU PS& Units Method Notes Biochemical Oxygen Demand 34 2.0 2.0 mg/L SM 5210 B-2011 Chemical Oxygen Demand 67 10 10 mg/L SM 5220D-2011 Total Suspended Solids 14 4.2 4.2 mg/L SM 2540D-2011 FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 3 of 8 ( : :c )O www.encolabs.com ANALYTICAL RESULTS 1 i. Description: Outfall 1 Lab Sample ID:CD01285-01 Received: 02/11/20 16:07 Matrix: Surface Water Sampled:02/11/20 09:45 Work Order:CD01285 Project: Stormwater Testing Sampled By:Joe Ladd Classical Chemistry ParametersIl ^-ENCO Cary certified analyte[NC 591] Analvte FCAS Numberl Results flan Units QE E12L EQl Batch Method Analyzed By Notes Biochemical Oxygen Demand^ 3.3 mg/L 1 2.0 2.0 0612005 SM 5210 8-2011 02/12/20 10:40 JOC Chemical Oxygen Demand^ 22 mg/L 1 10 10 0B17025 SM 5220D-2011 02/17/20 15:45 JOC Total Suspended Solids^ 83 mg/L 10 25 25 0B13004 SM 2540D-2011 02/13/20 09:29 BDC Description: Outfall 2 Lab Sample ID:CD01285-02 Received: 02/11/20 16:07 Matrix: Surface Water Sampled:02/11/20 10:15 Work Order:CD01285 Project: Stormwater Testing Sampled By:Joe Ladd Classical Chemistry Parameters 1 ^-ENCO Cary certified analyte[NC 591] Analvte ICAS Numberl Results flag Units DE MPS PQ.L latch Melba! Analyzed By Notes Biochemical Oxygen Demand^ 34 mg/L 1 2.0 2.0 0B12005 SM 5210 B-2011 02/12/20 10:40 JOC Chemical Oxygen Demand^ 67 mg/L 1 10 10 0B17025 SM 5220D-2011 02/17/20 15:45 JOC Total Suspended Solids^ 14 mg/L 1.67 4.2 4.2 0B13004 SM 2540D-2011 02/13/20 09:29 BDC FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 4 of 8 - o ► _ _ www.encolabs.com QUALITY CONTROL DATA h Classical Chemistry Parameters-Quality ControlII Batch 0812005-NO PREP Blank(0812005-BLK1) Prepared&Analyzed:02/12/2020 10:40 Spike Source %REC RPD Analvte Result Ela9 POl. Units Level Result %REC Linda RPD Limit Notes Biochemical Oxygen Demand 2.0 U 2.0 mg/L B-03 LCS(01312005-BS1) Prepared&Analyzed:02/12/2020 10:40 Spike Source %REC RPD Analvte Result Ilan P0k Units Level Result %REC Limits RPD Limit Notes Biochemical Oxygen Demand 200 2.0 mg/L 198 102 85-115 Duplicate(0B12005-DUP1) Prepared&Analyzed:02/12/2020 10:40 Source:CC20544-01 Spike Source %REC RPD Analvte Result Elan QUnitsLevel Result %REC Limits RPD Limit Notes Biochemical Oxygen Demand 6.7 2.0 mg/L 6.6 2 30 Batch 0813004-NO PREP Blank(0B13004-BLK1) Prepared&Analyzed:02/13/2020 09:29 Spike Source %REC RPD Analvte Result flan P0k Units Level Result %REC Limits RPD Limit Notes Total Suspended Solids 2.5 U 2.5 mg/L LCS(0B13004-B51) Prepared&Analyzed:02/13/2020 09:29 Spike Source %REC RPD Analvte Result Elan P0k Units Level Result %REC Limits RPD Limit Notes Total Suspended Solids 92 2.5 mg/L 100 92 80-120 Duplicate(0B13004-DUP1) Prepared&Analyzed:02/13/2020 09:29 Source:CD01285-01 Spike Source %REC RPD Analvte Result flea £01. Units Level Result %REC Limits RPD Limit Notes Total Suspended Solids 91 25 mg/L 83 9 20 Duplicate(0B13004-DUP2) Prepared&Analyzed:02/13/2020 09:29 Source:CD01495-02 Spike Source %REC RPD -Anal ite Result Ilan EQL Units Level Result %REC Limits RPD Limit Notes Total Suspended Solids 110 12 mg/L 110 3 20 Batch OB17025-Same Blank(0B17025-BLK1) Prepared:02/17/2020 12:02 Analyzed:02/17/2020 15:45 Spike Source %REC RPD Analvte Result flan POI. Units Level Result %REC jam& RPD Limit Notes Chemical Oxygen Demand 10 U 10 mg/L LCS(0B17025-BS1) Prepared:02/17/2020 12:02 Analyzed:02/17/2020 15:45 Spike Source %REC RPD _Malian Result Elan EQL Units Level Result %REC Limits RPD Limit Notes Chemical Oxygen Demand 500 10 mg/L 500 101 90-110 FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 5 of 8 ( 1 —am C) ► — www.encolabs.com QUALITY CONTROL DATA 1 Classical Chemistry Parameters-Quality Control Batch OB17025-Same-Continued L _Matrix Spike(0B17025-MS1) Prepared:02/17/2020 12:02 Analyzed:02/17/2020 15:45 Source:CC11394-01 Spike Source %REC RPD Analvte Result Flag POL Units Level Result %REC Unfits RPD Limit Notes Chemical Oxygen Demand 2600 40 mg/L 2000 620 100 90-110 Matrix Spike Dup(0B17025-MSD1) Prepared:02/17/2020 12:02 Analyzed:02/17/2020 15:45 Source:CC11394-01 Spike Source %REC RPD Analvte Result Flag POL Units Level Result %REC kraal RPD lima Notes Chemical Oxygen Demand 2600 40 mg/L 2000 620 100 90-110 0.3 5 FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 6 of 8 • — www.encolabs.com www.encolabs.com FLAGS/NOTES AND DEFINITIONS B The analyte was detected in the associated method blank. D The sample was analyzed at dilution. The reported value is between the laboratory method detection limit(MDL)and the laboratory method reporting limit(MRL),adjusted for actual sample preparation data and moisture content,where applicable. U The analyte was analyzed for but not detected to the level shown,adjusted for actual sample preparation data and moisture content,where applicable. E The concentration indicated for this analyte is an estimated value above the calibration range of the instrument.This value is considered an estimate. MRL Method Reporting Limit.The MRL is roughly equivalent to the practical quantitation limit(PQL)and is based on the low point of the calibration curve,when applicable,sample preparation factor,dilution factor,and, in the case of soil samples,moisture content. PQL PQL: Practical Quantitation Limit. The PQL presented is the laboratory MRL. N The analysis indicates the presence of an analyte for which there is presumptive evidence(85%or greater confidence)to make a"tentative identification". P Greater than 25%concentration difference was observed between the primary and secondary GC column. The lower concentration is reported. [CALC] Calculated analyte-MDL/MRL reported to the highest reporting limit of the component analyses. B-03 Blank exceeds the method required oxygen depletion of<0.20 mg/L. FINAL This report relates only to the sample as received by the laboratory,and may only be reproduced in full. Page 7 of 8 ( 1 — - ENVIRONMENTAL CONSERVATION LABORATORIES CHAIN-OF-CUSTODY RECORD ma al www.encolabs.can to775 Centre]port Dr. 48�0 F-xecubve Perk Cart.sole 11, ttrt-A Waodwnnds Industrial CL _ Orlando.FL 32824 Jacksonville,FL 3221660e9 Cary,NC 27511 1407)82&531a Jacksonville,(904)�s aoo� Fax(904)288 s2,o (919)467-30e0 Fax(919)as735 fs Page of Client Name Project NuMer Analyses Requested Turnaround Navozymes North America(N0008) [none] Times Address Project NnadDsse Note:Rush requests subpG to 77 Perry Chapel Church Road Stomnwater Testing acceptance by the taclty Cily/ST/Zp Poe/Oiling trio Franklinton,NC 27525 3800487045 o CI 0 _Standard Tel Fax Reporting Contact 0 W - 484-3370 Jae Ladd in i 6/''.. Expedited Sanple,s)Name.Affiliation(Print) Biling Contact . N +S� 1 n !Jourz.rwt4 S Accounts Payable V) Cl) Due /_/ Sampler(s) . site Location/Terte zone 'Y O O tab Worko der 2,4, /} l� ��ivtt'C.�in�. m U 1...2 - l/�_�^�^/1 R ��(See Codes)(Combine as necessary) y V�/ ■��+5 Collection Matrix Total a of rem• Sample ID(Field identification) le line Comp I Grab see codes) Containers Sample Comments _ Outfal 1 0 t t?!J-43 04345. 6 & SW 3 X X X See(2cnutex 'S Outfal 2 C2/)J 1b2,c 14I S Gib SW 3 X X X — �elbW <-Total#of Containers Sample Kit Prepared By Date/Time Relinquished By cone Received DalarTme 0-� L // I(f a 2-(( .)k.CmilmantreaoecWI Reporting Requirements rivitnOilihed By 2 '/S/.lpme �f coal� �7` P' " • �• Relinquished By Date/Tine •� Daia,Tme • • Cooler I s&Temps on Receipt 'Condeon Upon RScellif 5. (0 Acceptable Unacceptable Matrix:Gw-Groundwater SO-Soil OW-Drinking Water SE-Sediment SW-Surface Water WV-Wastewater A-Air 0-Other Metal in comments) Preservation:41ce H-HCI N-HNO3 SH2SO4 NO-NaOH 0-Other(detail in comments) Noe:Al samples submitted to ENCO Labs are in accordance with the terms and conditions listed on the reverse of this form,unless prior written agreements exist Sample Preservation Verification ENCO Cary (Epjcc )` Work Order: CD01285 Project: Stormwater Testing Client: Novozymes North America (N0008) Project#: [none] Logged In: 11-Feb-20 16:16 Logged By: Rachel Ann Yonis 2.1 1 1 7 Preservation Check Performed By: N Date/Time: 7-0 1 CD01285-01 Cont T Pres(pH) pH Checked/ j Date/Time Used/Comments Type Requirement In Control pH Adjusted Adjusted Reagent C 250mLP+H2SO4 <2 L%/ N / NA Y / // NA CD01285-02 Cont Type Pros(pH) pH Checked/ Datefiime Requirement In Control pH Adjusted Adjusted Reagent Used/Comments C 250mLP+H2SO4 <2 A,_()1 N / NA Y (N)NA Reagent Name ID Reagent Name ID Reagent Name ID 1 3 5 .2 4 6 pH Strip ID: PH Strips COA0898 C:1elmnt\Prir,.,..,...... ,..,,.a.,..,,.,„m..,,,,tat Page 1 of 1