Loading...
HomeMy WebLinkAboutNC0088200_Compliance Evaluation Inspection_20200204ROY COOPER Governor MICHAEL S. REGAN Secretary LINDA CULPEPPER Director Kelly Craver City of Thomasville PO Box 368 Thomasville, NC 27361-0368 NORTH CAROLINA Environmental Quality February 4, 2020 Subject: Compliance Evaluation Inspection Report NPDES Permit NCO088200 Thomasville WTP, Davidson County Dear Mr. Craver: On January 16, 2020, Paul DiMatteo of the Division of Water Resources (Division), Winston- Salem Regional Office met with Misty Conder, Operator in Responsible Charge (ORC), to conduct a Compliance Evaluation Inspection of the above referenced wastewater treatment plant. This inspection consists of (1) a review of the permit and accompanying documentation to determine compliance with permit conditions, and (2) an on -site inspection of several collection system components. The attached inspection form notes the areas that were evaluated for the inspection, with any notable findings outlined as follows. Item of Concern — Flow Measurement. Please note that the Permit requires flow measurement devices to be calibrated at least "once per year and maintained to ensure the accuracy of the measurements is consistent with the accepted capability of that device." The facility uses a closed channel flow meter, which the operator said was difficult to have calibrated due to having no way to access a secondary measurement in or around the channel. In these cases, a secondary device that has been calibrated off -site may need to be utilized. Please ensure that the flow measurement device is calibrated as required. If you have any questions concerning this report please contact Paul DiMatteo at (336) 776-9691 or Lon Snider at (336) 776-9800. Sincerely, DocuSig ed by: T sMa� on ''9 n1C err, Regional Supervisor Water Quality Regional Operations Section Winston-Salem Regional Office Division of Water Resources, NCDEQ Enclosures — Inspection Report CC: WSRO Laserfiche Files D E QNorth Carolina Department of Environmental Quality I Division of Water Resources Winston-Salem Regional Office 1 450 West Hanes Mill Road, Suite 300 I Winston-Salem, North Carolina 27105 `_ D+� Mof�w�^ L lOnifi*\ 336.776.9800 United States Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 IN 1 2 15 I 3 I NCO088200 111 12 I 20/01/16 I17 18 I S J 19 L G] 201 I 211111 I I I I I I II I I I I I I I I I I I I I I I I I I I I I I I II I I I I I f6 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 QA ---------------------- Reserved ------------------- 671 70 I I 71 I I 72 I r I 73 I I 174 751 I I I I I I I80 u ty I I i Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES oermit Number) 12:30PM 20/01/16 19/09/01 City of Thomasville WTP 200 Old Lexington Rd Exit Time/Date Permit Expiration Date Thomasville NC 273610368 01:30PM 20/01/16 24/04/30 Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Number(s) Other Facility Data Leigh A Conder/ORC/336-475-4246/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Kelly Craver,PO Box 368 Thomasville NC 273610368/City Manager/336-475-4220/3364754283 No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Flow Measurement Operations & Maintenance Records/Reports Self -Monitoring Program Sludge Handling Disposal Facility Site Review Effluent/Receiving Waters Laboratory Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Paul DiMatteo Docusigned by: DWR/WSRO WQ/336-776-9691/ 2/4/2020 4� F10C7C2E5BB34D4... Signature of Management Q A Reviewer Docusigned by: Agency/Office/Phone and Fax Numbers Date E- '? SWer 2/4/2020 EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page# NPDES yr/mo/day Inspection Type NCO088200 I11 121 20/01/16 117 18 JCJ Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Page# Permit: NCO088200 Owner -Facility: City of Thomasville WTP Inspection Date: 01/16/2020 Inspection Type: Compliance Evaluation Operations & Maintenance Yes No NA NE Is the plant generally clean with acceptable housekeeping? 0 ❑ ❑ ❑ Does the facility analyze process control parameters, for ex: MLSS, MCRT, Settleable ❑ ❑ ❑ Solids, pH, DO, Sludge Judge, and other that are applicable? Comment: Permit Yes No NA NE (If the present permit expires in 6 months or less). Has the permittee submitted a new ❑ ❑ ❑ application? Is the facility as described in the permit? 0 ❑ ❑ ❑ # Are there any special conditions for the permit? ❑ 0 ❑ ❑ Is access to the plant site restricted to the general public? 0 ❑ ❑ ❑ Is the inspector granted access to all areas for inspection? 0 ❑ ❑ ❑ Comment: Record Keeping Yes No NA NE Are records kept and maintained as required by the permit? 0 ❑ ❑ ❑ Is all required information readily available, complete and current? 0 ❑ ❑ ❑ Are all records maintained for 3 years (lab. reg. required 5 years)? 0 ❑ ❑ ❑ Are analytical results consistent with data reported on DMRs? 0 ❑ ❑ ❑ Is the chain -of -custody complete? 0 ❑ ❑ ❑ Dates, times and location of sampling Name of individual performing the sampling Results of analysis and calibration Dates of analysis Name of person performing analyses Transported COCs Are DMRs complete: do they include all permit parameters? ❑ ❑ ❑ Has the facility submitted its annual compliance report to users and DWQ? ❑ ❑ ❑ (If the facility is = or > 5 MGD permitted flow) Do they operate 24/7 with a certified operator ❑ ❑ ❑ on each shift? Is the ORC visitation log available and current? ❑ ❑ ❑ Is the ORC certified at grade equal to or higher than the facility classification? ❑ ❑ ❑ Is the backup operator certified at one grade less or greater than the facility classification? ❑ ❑ ❑ Is a copy of the current NPDES permit available on site? ❑ ❑ ❑ Page# 3 Permit: NCO088200 Owner -Facility: City of Thomasville WTP Inspection Date: 01/16/2020 Inspection Type: Compliance Evaluation Record Keeping Yes No NA NE Facility has copy of previous year's Annual Report on file for review? ❑ ❑ 0 ❑ Comment: Reviewed DMRs from 10/2018 and 8/2019. Lagoons Yes No NA NE Type of lagoons? Facultative # Number of lagoons in operation at time of visit? 1 Are lagoons operated in? # Is a re -circulation line present? ❑ ❑ 0 ❑ Is lagoon free of excessive floating materials? 0 ❑ ❑ ❑ # Are baffles between ponds or effluent baffles adjustable? ❑ ❑ ❑ Are dike slopes clear of woody vegetation? 0 ❑ ❑ ❑ Are weeds controlled around the edge of the lagoon? 0 ❑ ❑ ❑ Are dikes free of seepage? 0 ❑ ❑ ❑ Are dikes free of erosion? 0 ❑ ❑ ❑ Are dikes free of burrowing animals? 0 ❑ ❑ ❑ # Has the sludge blanket in the lagoon (s) been measured periodically in multiple 0 ❑ ❑ ❑ locations? # If excessive algae is present, has barley straw been used to help control the growth? 0 ❑ ❑ ❑ Is the lagoon surface free of weeds? 0 ❑ ❑ ❑ Is the lagoon free of short circuiting? 0 ❑ ❑ ❑ Comment: Effluent Pipe Yes No NA NE Is right of way to the outfall properly maintained? 0 ❑ ❑ ❑ Are the receiving water free of foam other than trace amounts and other debris? 0 ❑ ❑ ❑ If effluent (diffuser pipes are required) are they operating properly? 0 ❑ ❑ ❑ Comment: Flow Measurement - Effluent Yes No NA NE # Is flow meter used for reporting? 0 ❑ ❑ ❑ Is flow meter calibrated annually? ❑ 0 ❑ ❑ Is the flow meter operational? 0 ❑ ❑ ❑ (If units are separated) Does the chart recorder match the flow meter? 0 ❑ ❑ ❑ Page# 4 Permit: NC0088200 Inspection Date: 01/16/2020 Owner -Facility: City of Thomasville WTP Inspection Type: Compliance Evaluation Flow Measurement - Effluent Yes No NA NE Comment: A doppler device is used at the effluent. Mrs. Conder said she wasn't aware how such a meter could be calibrated. Page#