Loading...
HomeMy WebLinkAboutNC0021920_Pretreatment_Annual_Report_20200225Darren Currie ;�.1i rvi. City Manager o Bombe Williams City Clerk - n 317 S. Madison Street PO Box 607 1833 Whlteville, NC28472 910-642-8046 Whilevillecitvne,eov February 25 2020 Ms. Vivien Zhong Environmental Engineer PERCS Unit Division of Water Resources Department of Environmental Quality 1617 Mail Service Center Raleigh, NC, 27699-1617 Subject: PAR 2019 Dear Ms. Vivien: Terry L. Mann Mayor Justin S. Smith Mayor Pro- Tem Tim Blackmon Council Member Jimmy Clarida Council Member Tim Collier Council Member Robert Leder Council Member Kevin G. Williamson Council Member Please find enclosed for your review: the Pretreatment Annual Report (PAR) covering January through December 2019. Thanks for all of your help. If you have any questions, please contact me at 910-642-5818. Sincerely, Brandon Rich Pretreatment Coordinator Enclosure: PAR 2019 Allocation Table Pretreatment Info Database Cc: Tom Tharrington NCDENR/DWQ, Wilmington Region City of Whiteville (NPDES # NC0021920) 2019 PAR Narrative GENERAL INFORMATION: GENERAL PROGRAM INFORMATION: AT, SUO, ERP, IWS, LTMP are up to date. GENERAL PERMIT INFORMATION: Permit for Columbus Regional HealthCare is due for renewal on 3/15/2021. Permit for Clean Water Solution is due for renewal on 1/14/20 SIU INFORMATION, listed alphabetically Clean Water Solutions (IUP # 0006) Notice of Violation was issued on November 6, 2019 for Zinc limit violation. Zinc SNC violation is due to only one sample taken within the last 6 months of the year that was above the limit. Oil & Grease results are not recorded due to commercial laboratory failing to add O&G to the sampling schedule. Columbus Regional HealthCare (IUP # 0001) SNC INFORMATION: - This SIU was compliant for this PAR year. Waste Reduction Activities: The City of Whiteville has contracted recycling services with Waste Management. Waste Management provides recycling for plastic, glass (green, brown, and clear), aluminum, newspaper, magazines, and curbside pick up of lawn debris. Our Industries themselves participate in several waste reduction activities. These are outlined on the following pages. Chapter 9, PAR Guidance Pretreatment Performance Summary (PPS) 1 2 3. 4. 5. 6. 7. 8 9 10 11 12. 13. 14. 15. 16. 17. Pretreatment Town Name: Whiteville "Primary" NPDES Number NC00 21920 or Non Discharge Permit # if applicable => PAR begin Date, please enter 01 /01 /yy or 07/01 /yy 3. => 1 /01 /19 PAR end Date, please enter 06/30/yy or 12/31/yy 4. => 12/31/19 Total number of SIUs, includes CIUs 5. => 2 Number of CIUs 6. => 0 Enter the Higher Number, either (7a) or (7b) here => 0 7a. Number of SIUs not sampled by POTW 7a. => 0 7b. Number of SIUs not inspected by POTW 7b. => 0 Number of SIUs with no IUP, or with an expired IUP 8. => 0 Total Number of SIUs in SNC due to either IU Reporting violations or IUP Limit violations. To avoid double counting some SIUs Enter ( 9a + 9b ) - 9c here => 1 Enter the Number of SIUs in SNC for: 9a. IU Reporting violations 9b. IUP Limit violations 9c. Both IU Reporting & Limit violations Number of SIUs in SNC due to IU Reporting violations that were not sampled or inspected by POTW Number of SIUs in SNC due to violation of Compliance Schedule due dates Number NOVs, NNCs, AOs, or similar assesed to SIUs Number Civil or Criminal Penalties assessed to SIUs Number of SIUs included in public notice Number of SIUs from which penalties collected Total Amount of Civil Penalties Collected 16. => $ Total Number of SIUs on a compliance schedule Foot Notes: AO Administrative Order CIU Categorical Industrial User CO Consent Order IUP Industrial User Pretreatment Permit NNC Notice of Non -Compliance 9a. => 0 9b. => 1 9c. => 0 10. => 0 11. => 0 This Column for office use only EPA WENDB PSSD PSED SIUS CIUS NOIN NOCM PSNC MSNC SNPS SNIN SSNC 12. => 1 FENF 13. => 0 JUDI 14. => 0 SVPU 15. => 0 IUPN 0 17. => 0 NOV Notice of Violation PAR Pretreatment Annual Report POTW Public Operated Treatment Works SIU Significant Industrial User SNC Significant Non -Compliance, formerlv RNC 091M Chapter name: PAR Guidance File name: PAR PPUdfngm iei®vdaftriAckgiUdptt99A Section B, Page 5 Blank PPS Form, Copy and use in your PAR Pretreatment Annual Report (PAR) Significant Non -Compliance Report (SNCR) SNC LIMITS Violations Only Use separate sheet for each WWTP Cover year of report and previous year Discuss actions taken in response to SNC in narrative Control Authority, Town Name => Whiteville WWTP Name => Whitemarsh NPDES # _> NCO021920 PAR begin date => 1-Jan-19 PAR end date => 31-Dec-19 Check here if no SIU's in SNC for periods 1, 2, 3, 4 => Note: The information on this form does not confirm or deny that an industry contributed to NPDES violations. IUP # Pipe # Industry Name Parameter SNC Y/N STATUS (NC, RP, or R) 1 2 3 4 1 2 3 4 0006 001 Clean Water Solution Zinc Y NC 1 - Previous Pretreatment Annual Report Year -1st 6 months: 2 - Previous Pretreatment Annual Report Year-2nd 6 months: 3 - Current Pretreatment Annual Report Year-1 st 6 months: 4 - Current Pretreatment Annual Report Year-2nd 6 months: uates: from 01/01/18 to 06/30/18 from 07/01/18 to 12/31/18 from 01/01/19 to 06/30/19 from 07/01/19 to 12/31/19 if ESViolation =©©0 NC - Non compliant (SNC and no schedule issued) RP - Resolved pending (SNC and schedule issued) R - Resolved (no SNC and schedule completed; or permit modified, no SNC, and no overallocation) Comprehensive Guide, Chapter 9, Section B, page 8 Blank SNCR Form, Copy and use in your PAR PAR-SNCR Page 1 of 1 Chapter name: PAR Guidance File name: PAR SNCR.xls Revision date: August I, 1994 Pretreatment Annual Report (PAR) Industrial Data Summary Form (IDSF) Use separate forms for each industry/pipe Enter BDL values as < (value) Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) => * or Average (mg/1) => * or Average Loading (lb/d) => % violations,(chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) => * or Average (mg/1) => * or Average Loading (lb/d) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) => * or Average (mg/1) => * or Average Loading (lb/d) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Control Authority, Town Name => WWTP Name => NPDES # => 1 st 6 months, dates => 2nd 6 months, dates => Whiteville Whitmarsh 01/01/19 to 06/30/19 07/01/19 to 12/31/19 Industry Name Columbus Regional Healthcare IUP # 0001 Pipe # 01 Flow mad BOD TSS Ammonia I st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 12nd6months 1st 6 months 2nd 6 months 10 10 4 4 4 4 1 1 0.081 0.092 236 95 138 68 18 8.46 0.073 0.083 123.25 74.75 93.0 56.0 18.00 8.46 ** ** ** ** Arsenic Cadmium Chromium Col per 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1 1 1 1 1 1 1 1 <0.010 <0.010 <0.010 <0.010 <0.010 <0.010 0.066 0.040 <0.010 <0.010 <0.010 <0.010 <0.010 <0.010 0.066 0.040 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** C anide Lead Me cury Nickel 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1 1 1 1 4 4 1 1 <0.005 <0.005 <0.010 <0.010 <0.0002 <0.0002 <0.010 0.010 <0.005 <0.005 <0.010 <0.010 <0.0002 <0.0002 <0.010 0.010 ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** ** BDL => Below Detection Limit mg/I => milligrams per liter * POTW must enter at least one of these IUP => Industrial User Permit Ib/d => pounds per day four rows, Please indicate how averages were calculated SNC => Significant Non -Compliance mgd => million gallons per day Avg period could be month, Qtr, or 6-mouth & if BDL, 1/2BDL, or zero values used. TRC => Technical Review Criteria WWTP => wastewater treatment plant ** Moniter Only ** Moniter Only ** Moniter Only Chapter: PAR Guidance File name: PAR_IDSF.xls Revision date: August 1, 1994 Page I of Pretreatment Annual Report (PAR) Industrial Data Summary Form (IDSF) Use separate forms for each industry/pipe Enter BDL values as < (value) Total # of samples => * Maximum (mg/1) _> * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) _> % violations, (chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> Total # of samples => * Maximum (mg/l) _> * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) _> % violations, (chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> Total # of samples => * Maximum (mg/1) _> * or Maximum (lb/d) _> * or Average (mg/1) _> * or Average Loading (lb/d) _> % violations, (chronic SNC is >= 66%) _> % TRC violations, (SNC is >= 33 %) _> Industry Name Columbus Regional Healthcare page 2 IUP # Pipe # Silver Zinc On & rease Irtiospnorus 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 4 4 1 1 4 4 1 1 <0.010 <0.010 0.085 0.033 21 59 3.72 2.43 <0.010 <0.010 0.085 0.033 14.0 22.25 3.72 2.43 ** ** ** ** ** ** ** ** WIN 311161111IM --1 D 1UW LCLCULIUII Lmllt * POTW must enter at least one of these IUP => Industrial User Permit four rows, Please indicate how averages were calculated SNC => Significant Non -Compliance Avg period could be month, Qtr, or 6-month & if BDL , 1/2BDL, or zero values used. TRC => Technical Review Criteria ** Moniter Only ** Moniter Only Chapter: PAR Guidance File name: PAR_IDSF.xls Revision date: August I, 1994 mgn =� muugrams per user Ib/d => pounds per day mgd => million gallons per day WWTP => wastewater treatment plant ** Moniter Only Page a of a Pretreatment Annual Report (PAR) Industrial Data Summary Form (IDSF) Use separate forms for each industry/pipe Enter BDL values as < (value) Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) => * or Average (mg/1) => * or Average Loading (lb/d) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) => * or Average (mg/1) => * or Average Loading (lb/d) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) => * or Average (mg/1) => * or Average Loading (lb/d) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Industry Name Clean Water Solution IUP # 0006 Pipe # 001 w m d Benzene Eth lbenzene X lenes ff 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 7 7 7 7 7 7 7 0.005 13.0 29.4 13.0 9.3 1.2 106.0 0.002 0.003 2.2 5.5 2.0 1.8 0.5 19.3 MTBE Na hthalene Lead Bis(2-eth Ihex 1) hthalate 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 7 7 7 7 7 7 7 7 12.1 87.9 13.0 2.9 13.0 10.9 87.7 35.1 1.9 20 2.3 1.6 6.4 6.1 22.1 9.3 Carbazole Fluoranthene n-Decane n-Octadecane 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 7 7 7 7 7 7 7 7 <0.10 <0.99 2.5 <0.16 312 2.5 393 16.7 <0.10 <0.2 <0.5 <0.2 46.5 1.0 63 6.6 * POTW must enter at least one of these four rows, Please indicate how averages were calculated Avg period could be month, Qtr, or 6-month & if BDL, 1/2BDL, or zero values used. ** Moniter Only BDL => Below Detection Limit IUP => Industrial User Permit SNC => Significant Non -Compliance TRC => Technical Review Criteria ** Moniter Only mg/I => milligrams per liter Ib/d => pounds per day mgd => million gallons per day WWTP => wastewater treatment plant ** Moniter Only Chapter: PAR Guidance File name: PAR IDSF.xls Revision date: August 1, 1994 page i of a Pretreatment Annual Report (PAR) Industrial Data Summary Form (IDSF) Use separate forms for each industry/pipe Enter BDL values as < (value) Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) => * or Average (mg/1) => * or Average Loading (lb/d) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) => * or Average (mg/l) => * or Average Loading (lb/d) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Total # of samples => * Maximum (mg/1) => * or Maximum (lb/d) => * or Average (mg/1) => * or Average Loading (lb/d) => % violations, (chronic SNC is >= 66%) => % TRC violations, (SNC is >= 33 %) => Industry Name Clean Water Solution page 2 lUP # Pipe # Oil & Grease Chromium Cobalt Co er 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1st 6 months 2nd 6 months 1 1 1 1 1 1 1 1 ! ! <10.0 <10.0 <50.0 <50.0 <25.0 43.1 ! ! <10.0 <10.0 <50.0 <50.0 <25.0 43 ** ** ** ** m Linc 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 st 6 months 2nd 6 months 1 1 1 1 <50.0 <50.0 170 237 <50.0 <50.0 170 237 1 st 6 months 2nd 6 months 1st 6 months 2nd 6 months 11st6months 2nd 6 months 1st 6 months 2nd 6 months BDL => Below Detection Limit * POTW must enter at least one of these IUP => Industrial User Permit four rows, Please indicate how averages were calculated SNC => Significant Non -Compliance Avg period could be month, Qtr, or 6-month & if BDL, 1/2BDL, or zero values used. TRC => Technical Review Criteria ** Moniter Only ** Moniter Only Chapter: PAR Guidance File name: PAR_IDSF.xls Revision date: August 1, 1994 mg/I => milligrams per liter Ib/d => pounds per day mgd => million gallons per day WWTP => wastewater treatment plant ** Moniter Only Page % of �l PUBLIC NOTICE OF SIGNIFICANT INDUSTRIAL WASTEWATER PERMITVIOLATIONS The City of Whiteville, in accordance with 40 CFR Section 403.8 of the State and Federal Pretreatment Regulations, promulgated by the United States Environmental Protec- tion Agency, hereby provides the public with notice that the City collected and ana- lyzed samples from the wastewater discharge of Industrial Users between January 1 and December 31, 2019.. No Industrial Users were found to be insignificant non-com- pliance during this period. Newlyn McCullen,.Pretreatment Director Whiteville Wastewater Reclamation Facility 1000 Nolan Avenue Whiteville, N.C. 28472 Brandon Rich, Pretreatment Coordinator Whiteville Wastewater Reclamation Facility 1000 Nolan Avenue Whiteville, N.C. 28472 City of Whiteville Oil and Grease Awareness Did you know that cooking grease is the main cause of most residential sewer line and City sewer system blockages? These blockages can result in sewer spills throughout the City. Cooking grease coats the inside walls of sewer pipes, similar to the way fatty foods can clog your arteries. The grease that clings to the pipe builds up over time and acts as a host for other materials to cling torestricting the size of the pipe even more. Eventually the pipe becomes completely clogged and sewer will back up either in the homeowner's yard or through a man- hole into the City streets and possibly to nearby streams. By doing a few simple things in your home or business, you can help prevent costly sewer spills and reduce environmental impacts associated with spills. Listed below are things to remember: • All cooking oils (including salad oil, frying oil, bacon fat, and marinades) need to be poured into a container. The container can be an old milk carton, frozen juice container or other non -recyclable container and disposed of in the garbage. You may use cat litter or used coffee grounds to absorb the liquid in the container. • Dry wipe all pots and dishes. Use a paper towel or napkins to remove greasy leftovers from pots and dishes prior to washing in the sink or dishwater. • Place leftover foods, fat trimming from meat etc. in the trashcan instead of the garbage disposal. • Whenever meat is drained in a colander, place the colander over newspaper instead of the sink, and then throw the newspaper away. • Never dump motor oil or other lubricants down the drain. Take them to a collection point. Paste Clipping of Advertisement Here. NORTH CAROLINA, COLUIVIBUS COUNTY: AFFIDAVIT OF PUBLICATION Before the undersigned, a Notary Public of said County and State; duly commissioned, qualifieA and authorizz;d by law to administer oaths, personally appeared ...... ....r-X.<........ ...Gf�J............................... who being first duly sworn, deposes and says: that he is the .....Pik owner, publisher or employee authorized to make this affidavit) of The News Reporter Co., Inc. engaged in the publication of a newspaper known as THE NEWS REPORTER, published, issued and entered as second class mail in the CITY of Whiteville, in said County and State: that the notice or other legal advertisement, a true copy of which is attached hereto; was published in theAews Reporter on the following dates: -------------------- jA,..�.r.�4.&Q................................ and that the said newspaper in which such notice, paper, document, or legal advertisement was published was. at the time of each and every such publication, a newspaper meeting all of the requirements and qualifications of section 1-597 of the General Statutes of North Carolina and was a qualified newspaper within the meaning of section 1-597 of the General Statutes of North Carolina. This .........�r--•-•---.day of ... ......... . ........ ................. (Signature Of Person Making Affidavit.) Sworn to and subscribed before me, this ...... //)................... day of --•---........7't� ......... ............ .............. 20. U... ,I �. Notary Public ilk My Commission expires .. D. .... q .............. . 2 0. �i� �A [SA:RAH E CRUTCHFIELD Notary Public mbus County, N, C. ission Expires 10/9/2024 Pretreatment Program Info Database for Program Name Whiteville WWTP Name City of Whiteville Program Approval Date 07/01/1983 Pretreatment Status Full Region WIRO County Columbus NPDES Number NC0021920 printed on: 12/20/2019 Stream Information 7 IWC °io at 7Q10 49.70 7Q10 Flow cfs / mgd 4.7 / 3.04 1Q10 Flow cfs / mgd 3.92 / 2.53 Stream Classification C-SW Basin Number LUM58 Receiving Stream Name WHITE MARSH NPDES Effective Date 05/01/2017 Last PAR Rec 02/26/2019 PAR Due Date 03/01/2020 mercury 1631 Expire Date 08/31/2019 NPDESYear Current Fiscal 08/27/2019 required PCI Done es POTW is Primary WWTP TRUE Last Audit on 09/13/2016 Audit Year Next20/21 Design Flow mgd 3.0000 % Design mgd is SIU permitted 4.17 Permitted SIU flow (mgd) [Pt—SIU) .125 WWTP SIU's 1 Program SIUs 1 ^IWS WWTPCIU's 0 Program ClUsP HWA LTMP SUO ERP� date Inactive Date Next Due 07/01/2020 01/31/2024 Date Received by DWR 02/11/2019 01/28/2019 04/30/2019 12/18/2013 07/15/2016 Date Approved 02/26/2019 03/05/2019 06/05/2019 02/18/2014 09/29/2016 Adopt Date Required Date Adopted 11/25/2014 Related NOVs from Toxictiy in July 2000 Toxicity in August 2000 Zn Sludge violation 2000 DWR Central Office Contact ivien Zhong DWR Regional Contact fom Tharrington