Loading...
HomeMy WebLinkAbout20200110 Ver 1_PLTS-GRADING AND DRAINAGE-C2.11_20200203c 4 Y W IY W 0 W J m m m I � n Z 00 Q N CY 00 z0 N Y � 0� 0 CN mN 0 n I W W ~ Eo N 0 J n 00 CS1 N 10 W CD C. ai Z N Q Y -5ry 0 w �I D 0 d Ire Err rLr 6rr 6' rWr 61r z _ 11/2" CLR. TYP . p: ° #4 REBARS :. I :. W J p I Q °C x I o a > a 3 I #5 REBARS 12" o' CENTERS_(TYP.) SECTION 'A -A' cc c J r U rLr + 1'-0" � B A r A #4 R BARS •o 0 � B 6rr rLr 6rr WAFFLE WALL PLAN VIEW 6rr 'L' 611 1" MIN. CLR. 0 = 4x4 W4xW4 uj 0 o' WWF (LAP WWF m 6" ONTO REBARS) o a cr #5 REBARS 12" p > CENTERS (TYP.) SECTION 'C-C' I SMOOTH SURFACE, REMOVE ALL DEBRIS AND SEED/MULCH BEFORE PLACING MATTING. e o #4 REBARS o0 : w o J THE PATTERN OF THE 00 co KNOCK -OUT 3" , PANELS ARE SHOWN I•' a x FOR ILLUSTRATIVE I:. m PURPOSES ONLY. 3 ( #5 REBARS /�l 2 CENTERS SECTION 'B-B' D v v o. . v •° z o � 1" MINP. . ' o CLR.(TYP) r 0 4x4 W4xW4 - WWF (LAP ° i WWF 6" ON- TO REBARS) v o v 1" MIN. CLR.(TYP) 4C #5 REBARS @ 12" CENTERS (HORIZ. & VERT.) (USE WITH 4' X 4' & LARGER DRAINAGE STRUCTURES D TYPICAL) SOLID WALL PLAN VIEW 6,r AWr 6rr 1" MIN. CLR. 4x4 W4xW4 WWF (LAP L o WWF 6" ON- o` Q TO REBARS) o .17 Q X #5 REBARS o' So: o: (TYPICAL)CENTER SECTION 'D-D' co ANCHOR MATTING IN 6" TRENCH WAFFLE WALL ISOMETRIC VIEW �'• v •• .. v v .::o. '• . o .::17 D. j:..'• o::.'D• a::.'D. o::.D• o::.'D• . •o. o . o . o.. o ••D•o SOLID WALL ISOMETRIC VIEW COCONUT STRAW MATTING PLACED FLUSH WITH BACK SURFACE, LAP OVER DOWNSTREAM/ DOWNSLOPE SEAMS. gopw 7:�: STREAM BANK REPAIR SCALE: NOT TO SCALE 12" WOOD STAKE PLACED IN 3' O.C. DIAMOND PATTERN -MATTIN ANCHORED 1' BELOW STREAM BED z oU) aQ cr U LLJCL 0 0 Ucr 2 uj U- U O H H CnHU- OJ 0OUa 1 C~ ' Q W o H LL V J zQr< � H � N Lu o LU u- Q a Z zoo Q U) G o H a J o N 0 o� °C W cc a HEET 1 OF 2 840.45 GENERAL NOTES: * THIS PRECAST BOX MAY BE USED FOR THE FOLLOWING STANDARDS: 840.01, 840.02, 840.04, 840.05, 840.13, 840.14, 840.15, 840.17, 840.18, 840.19, 840.26, 840.275 840.285 840.315 840.32 AND 840.41. * INSTALL PRECAST DRAINAGE STRUCTURES AND PAY FOR IN ACCORDANCE WITH SPECIFICATION SECTION 840. * DO NOT PLACE PRECAST DRAINAGE STRUCTURES UNDER TRAFFIC OR WHERE TRAFFIC WILL BE DETOURED. * USE 4000 PSI CONCRETE. * PROVIDE ALL REINFORCING STEEL WHICH MEETS ASTM A615 FOR GRADE 60 AND WELDED WIRE FABRIC CONFORMING TO ASTM A1064. * LIMIT MAXIMUM DEPTH TO TOP OF BOTTOM SLAB FOR WAFFLE WALL STRUCTURE TO 10'-0"; LIMIT SOLID WALL STRUCTURE TO 15'-0". * PLACE LIFT HOLES OR PINS IN ACCORDANCE WITH OSHA STANDARD 1926.704. • CUT OR FORM OPENINGS FOR PIPE TO PROVIDE REQUIRED SIZE AND LOCATION. ORIENT WAFFLE WALL STRUCTURES SO THAT PIPES ENTER THROUGH THE KNOCKOUT/WAFFLE PANELS ONLY. PIPES MAY ENTER THROUGH THE CORNERS OF SOLID WALL BOXES IF A MINIMUM OF 6" OF WALL IS PROVIDED ABOVE THE HOLE. * ALL ELEMENTS PRECAST TO MEET ASTM C913. * FRAME AND GRATE HEIGHT MAY BE ADJUSTED WITH CONCRETE OR BRICK IN ACCORDANCE WITH STANDARD 840.25. * PROVIDE PRECAST STRUCTURES OVER 4'-0" IN DEPTH WITH STEPS AS DIRECTED BY THE ENGINEER. * WELDED WIRE FABRIC MAY BE SUBSTITUTED FOR REBAR AS LONG AS THE SAME AREA OF STEEL IS PROVIDED. * SEAL JOINTS WITH A FLEXIBLE BUTYL RUBBER BASE CONFORMING TO FEDERAL SPECIFICATION SS-S-21A, AASHTO M-198, TYPE B - BUTYL RUBBER. * LIMIT MAXIMUM STRUCTURE SIZE TO INSIDE CLEAR DIMENSIONS OF 5'-0" X 5'-0". * THE OUTSIDE PIPE DIAMETER PLUS 2" OR THE OPENING REQUIRED FOR FRAME AND GRATE IS THE MINIMUM STRUCTURE SIZE WHICHEVER IS GREATER. • USE MANHOLE FRAME AND COVER AS INDICATED ON THE PLANS. REINFORCE OPENING AS SHOWN ON THIS SHEET. BOTTOM OF STREAM BED- - PROPOSED CULVERT TO BE BURIED 12" BELOW STEAM BED ELEVATION NCDOT STD. 838.80 PRECAST CONC. HEADWALL SEE SHEET C2.9 SECTION A -A SCALE: NOT TO SCALE OPENING SHALL BE LOCATED AS REQUIRED I STEPS I I C I #5 BARS @ OPENING 6" L' PLAN TOP SLAB Ci 'L' OR 'W' + 1'-0" z z 00 (A Q #4 REBARS 6" CENTERS - m a H cr U #5 BARS waQL2 @ OPENING Q U = O H SECTION 'C-C' U=U-oz_j 0OU)a °C z � o. TLu C 11 Wu o�� CORNER CUT DETAIL (SOLID WALL BOX) o 6" L' OR 'W' 6rr a y 0 W z #4 REBARS O Q 6" CENTERS cr a #4 REBARS :;r a Z Lu 1" 6" CENTERS z H CLR r < aLL. Z G Q PRECAST RISER PLAN PRECAST RISER DETAIL } Lu o N z D. :o .:,• a O v CC Lu a 6" 6" SECTION VIEW SECTION VIEW OPTIONAL JOINT DETAILS SHEET 2 of 2 840.45 NCDC PRECAST C( TYP.,EACF S NOTES: INSTALL ALL STEPS PROTRUDING 4" FROM INSIDE FACE OF STRUCTURE WALL. Z O� U STEPS DIFFERING IN DIMENSIONS, CONFIGURATION, OR MATERIALS FROM THOSE SHOWN MAY ALSO BE USED PROVIDED THE CONTRACTOR HAS FURNISHED Q Q THE ENGINEER WITH DETAILS OF THE PROPOSED STEPS AND HAS RECEIVED WRITTEN APPROVAL FROM THE ENGINEER FOR THE USE OF SUCH STEPS. 0 U \� 3a LLJOH OOP=z wazL= r 1 aUCCOH Cn F— LLO J frH 00U� - Z H 5 r win U t TT T 'Ste'. _ I_ PLAN SIDE ELEVATION PLAN SIDE ELEVATION - M� 5 _ N \ FL o0 W �� 1 I 14/2r I � 1 Q I CAST IRON CAST IRON z N ELEVATION ELEVATION Lu 7 cc BAR OR a 11 3 ;� 1 8/4 \GALV'D. #8 BAR za5/8 113/1,#6 rrU) W CS T a a PLAN T POLYPROPYLENE 0 Z 1/2" SIDE PLASTIC SIDE a Q 1�- /8' ELEVATION COMPOSITE PLAN ELEVATION G REINFORCING STEEL 12" ELEVATION NOTE: #3 DEFORMED 12" DO NOT USE IN STEEL ROD _ SANITARY SEWER MANHOLES. SHEET 1 OF 1 SECTION A -A ELEVATION 840.66 70 L.F. OF IMPACT SECTION B-B SCALE: NOT TO SCALE BOTTOM OF STREAM BED m z O m O LEI W Q 0 w m m O O O LL O N N � (n E ar O E W N � � O N Z O) J Y � � d a � N 3 N Q Z L W Lo Q ,co U 3 0f) W W Q Z > O I —I 13••I Q W CC) W �../ U) Z � o 1� c 4? O � W z f W W �o I� T� V Z L� m Cn ISSUED FOR: DATE: BY: m REVIEW 01/14/20 RDH n REVIEW 02/03/20 DOB c::) CD CD Z L _j LLI C7 JOB NO. GNW2001 .01 A c a SHEET CD E C2.1 1 C,