Loading...
HomeMy WebLinkAbout20200260 Ver 1_BR-0124 Permit Drawings_20200218Hi'hwOy North Carolina Department of Transportation StDllYlbvc7tt'; Highway Stormwater Program = STORMWATER MANAGEMENT PLAN '«- (Version 2.08; Released April 2018) FOR NCDOT PROJECTS WBS Element: 48833.1.1 TIP No.: BR-0124 County(ies): Wilkes Page 1 of 1 General Project Information WBS Element: 48833.1.1 ITIP Number: BR-0124 Project Type: Bridge Replacement Date: 12/27/2019 NCDOT Contact: David Stutts Contractor / Designer: STV Engineers, Inc. / Shirshant Sharma Address: 1020 Birch Ridge Drive Raleigh, NC 27610 Address: 900 West Trade Street, Ste. 715 Charlotte, NC 28202 Phone: 919 707-6442 Phone: 704 816-2556 Email: dstufts@ncdot.gov Email: Shirshant.Sharma stvinc.com City/Town: Tra hill, NC County(ies): Wilkes River Basin(s): Yadkin -Pee Dee CAMA County? No Wetlands within Project Limits? No Project Description Project Length (lin. miles or feet): 0.12 Surrounding Land Use: Agricultural, Rural, Residential, Wooded Proposed Project Existing Site Project Built -Upon Area (ac.) 0.5 ac. 0.4 ac. Typical Cross Section Description: Bridge : Two 10' lanes, 5' to the left and right paved shoulders. Shumate Mountain Road Approach: Two 10' lanes, variable paved shoulders. Middle Fork Road Approach: Two 10' lanes, variable paved shoulders. Bridge: Two 12' lanes, 2' to the left and right shoulders. Shumate Mountain Road Approach: Two 10' lanes, variable shoulders. Middle Fork Road Approach: Two 10' lanes, variable paved shoulders. Annual Avg Daily Traffic (veh/hr/day): Design/Future: N/A Year: 2040 Existing: 470 Year: 2016 General Project Narrative: (Description of Minimization of Water Quality Impacts) The existing 136', 3 span bridge over West Prong Roaring River on SR 1745 (Shumate Mountain Rd) is being replaced with a 3 span bridge with a span arrangement of 1@40' (21" cored slab), 1 @60' (24" cored slab), and 1@40' (21" cored slab). The bridge will have 1.5:1 sloping abutments. The bridge will have a normal crown slope at 2% with 10' travel lanes with 5' to the right and 5' to the left shoulders, 27' clear width and 30' OTO width. The existing bridge structure will be removed. Overall drainage patterns will be maintained. There are roadside ditches that flow towards the begin end of the bridge on both sides of the roadway which will be maintained in the proposed condition. There is a proposed ditch reconstruction on the right side of Middle Fork Road. On the end side of the bridge, a traffic bearing grated drop inlet with double frame and grates (2GI) is placed on both sides of the roadway in the shoulder berm gutter to pick up runoff from the bridge. Class -II riprap abutment protection on both banks of the stream is also proposed to prevent future erosion and stream migration. Deck drains will be required to meet spread criteria but the drains will not discharge directly above water. Waterbody Information Surface Water Body 1 : West Prong Roaring River NCDWR Stream Index No.: 12-46-1-(5) NCDWR Surface Water Classification for Water Body Primary Classification: Class C Supplemental Classification: None Other Stream Classification: None Impairments: None Aquatic T&E Species? No Comments: NRTR Stream ID: Buffer Rules in Effect: N/A Project Includes Bridge Spanning Water Body? Yes Deck Drains Discharge Over Buffer? N/A Dissi ater Pads Provided in Buffer? No Deck Drains Discharge Over Water Body? No (If yes, provide justification in the General Project Narrative) (If yes, describe in the General Project Narrative; if no, justify in the General Project Narrative) (If yes, provide justification in the General Project Narrative) I See Sheet 1A For Index of Sheets See Sheet 18 For Standard Symbology Sheet — DETOUR VICINITY MAP z N.T.S. STATE OF NORTH CAR®I INA DIVISION OF HIGHWAYS WILKES COUNTY LOCATION: BRIDGE #166 OVER WEST PRONG ROARING RIVER ON SR 1745 (SHUMATE MOUNTAIN RD) TYPE OF WORK: GRADING, DRAINAGE, PAVING, & STRUCTURE SURFACE WATER IMPACTS PERMIT BEGIN CONSTRUCTION \ �\ \\\ SITE 2 —Y— STA.11 + 80.00 BEGIN TIP PROJECT BR-0124 —L— STA.11 + 45.00 10 O � 11 0 END TIP PROJECT BR—0124 �z w� —L— STA.17 + 80.00 END BRIDGE -L- STA. 15+78.25 s C SR 1745 (SHUMATE MOUNTAIN RD.) i / BEGIN BRIDGE 1 aN —L— STA. 14+35.75 5 SITE 1 H� THIS PROJECT IS NOT WITHIN ANY MUNICIPAL BOUNDARIES. CLEARING ON THIS PROJECT SHALL BE PERFORMED TO THE LIMITS ESTABLISHED BY METHOD — GRAPHIC SCALES 50 25 0 50 100 PLANS 50 25 0 50 100 PROFILE (HORIZONTAL) 5 2.5 0 5 10 PROFILE (VERTICAL) DESIGN DATA ADT 2016 = 470 ADT 2040 = N /A DHV = N/A D = N/A T = N /A V = 45 MPH FUNC. CLASSIFICATION: LOCAL SUB REGIONAL TIER STATE 8TAT8 PROJECT REPERENC6 NO. BR-0124 SPATE PROJ.NO. .APROI. NO. 48833.1.1 48833.2.1 ffiET TOTAL N0. BREETB S �CRIPI'[ON P.E. R.O.W/UTILITIES PERMIT DRAWING DOCUMENT NOT CONSIDERED FINAL SHEET 1 OF 5 UNLESS ALL SIGNATURES COMPLETED PROJECT LENGTH PLANS PREPARED FOR THE NCDOT BY: STV100 STV Engineers, Inc. 1 V soo West sae is HYDRAULICS GINEER LENGTH OF ROADWAY TIP PROJECT BR-0124 = 0.093 MILES LENGTH OF STRUCTURE TIP PROJECT BR-0124 = 0.027 MILES cbnriolce, NC zezaz NCTrade2 20 NC license Number F-0991 ®f HUNyy cr 2018 STANDARD SPECIFICATIONS TOTAL LENGTH OF TIP PROJECT BR-0124 = 0.120 MILES RIGHT OF WAY DATE. 1 2/I S12 01 9 NIKKI T. HONEYCUTT, PE P.E. ROADWAY DESIGN PROJECT ENGINEER ENGINEER ®p 8R RM8Q NCDOT CONTACT: DAVID STUTTS, PE LETTING DATE: BHUPESH R. JOSHI, EIT PROJECT DESIGNER Structures Management Unit 6/I6/2020 P.E. DETAIL C SPECIAL CUT DITCH (Not to Scale) c Front a 1 NaNral C, c Ditch Ground ?') D \oge Slope d Min. D-1.5 Ft. Type of Liner= PSRM Max d=1.5 Ft. FROM -Y- STA. 11+80 TO STA. 12+00 RT DECK DRAINS REQUIRED 9� 8" X 6" SLOTS ON 10' CENTERS (LT & RT) FROM STA. 14 + 44 TO STA. 14 + 64 F� FROM STA. 15 + 44 TO STA. 15 + 64 \\ \ BO0 O� \ PERMANENT IMPACTS IN SURFACE WATER = S2 SPECIAL CUT DITCH — O(DETAIL C) WORTH WINEBARGER AND WIFE, REBECCA WINEBARGER DECK DRAINS (TYP.) 8"x6" SLOTS ON IO' CENTERS (LT & RT) E 00 O O lIr � O SPECIAL LATERAL 'V' DITCH — C� (DETAIL D) CL-I RIPRAP & GEOTEXTILE (DETAIL E) 24" RCP -IV LU I, WOODS REMOVE & REPLACE F �HUMA= TE _ OUNTA/N WOOD a DETAIL A PIPE OUTFALL STABILIZATION (Not to Scale) 24" RCP —IV NATURAL EX. 48" CMP GROUND r CL-I RIPRAP CL-I RIPRAP GEOTEXTILE FROM -Y- STA. 12+32 LT TO STA. 12+80 LT \\- 00 BEGIN CONSTRUCTION BR -0I24 \ -Y- POT STA. 11+80.00 j O I Ujl I t I 1 CL-I RIPRAP & G (DETAIL A) , TEMPORARY IMPACTS IN SURFACE WATER =S1 mlo � X � z N ►/ RETAIN 48" CMP CL-II RIPRAP EXCAVATION BEGIN T/P PROJECT BR-0124 CL-II RIPRAP & GEOTEXTILE Q (DETAIL F) -L- POT STA. 11 +45.00 STREAMBANK STABILIZATION 3 CL-II RIPRAP & GEOTEXTILE DECK DRAINS (TYP.) 8"x6" SLOTS ON (DETAIL F) IO' CENTERS (LT & RT) PERMANENT IMPACTS / Permit Drawing IN SURFACE WATER =S1 Sheet 4 Ot 5 GRAPHIC SCALE �PDE LU p � � DETAIL F STREAMBANK STABILIZATION .. ( Ni to Scale) PROPOSED PIERS ABUTMENT EXCAVATION DECK DRAIN J "PRAP PAD EXISTING PIERS — (TO BE REMOVED) 2' MIN of Liner = 115 CL-II Rif exfilr - ABUTMENT EXCAVATIO DECK DRAIN RIPRAP PAD tITE)M -IRIPRAP LE —NWSEL STREAMBED DECK DRAINS (TYP.) 8"x6" SLOTS ON IO' CENTERS (LT & RT) CL-II RIPRAP & GEOTEXTILE (DETAIL F) C CL-II RIPRAP & GEOTEXTILE (DETAIL F) WOODS 0 `, STV Engineers, Inc. PROJECT REFERENCE NO. STY 100 900 West Trnde St., 5,ute 715 BR-0124 charlotte, NC 28202 NC License Number F-0991 FW SHEET NO. ROADWAY DESIGN ENGINEER SHEET NO. A HYDRAULICS ENGINEER DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED LEGEND ®DENOTES TEMPORARY IMPACTS IN SURFACE WATER ®DENOTES IMPACTS IN SURFACE WATER -L- P/ Sta //+22J3 P/ Sta 12+93.00 A = /6' 55' 442r (LT) A = 7' 54 082r (LT) D = 9' 32' 575' D = 44628.P L = 17728' L = 16550' T = 8929' T = 82BW R = 600,W R = 1,200A0' P/ Sta 17+4098 P/ Sto 18+43A7 A = 5'18' 232' (RT) A = 6'06' 02P (RT) D = 405' 332' D = 8' lY 06.4' L = /21W L = 7453' T = 6488' T = 3730' R = /,400W R = 70040' Pl Sta 11+6298 P/ Sta 13+05.49 A = 67 56 JT (RT) A = 25 49 /72' (LT) D = 4404 252r D = 47 49'20P L = /54J5' L = 51BY T = 8759' T = 2636' R = /30w R = 115.00' PAS TIID \�F_ -- F — F — - - r' X X�X. PASTURE �STIr►r X \ LU TOE PROTECTION 0- CL-I RIPRAP & GEOTEXTIL PDE (DETAIL B) • \'­ CL-B RIPRAP & GEOTEXTILE 29 16 CL-II RIPRAP -RETAIN 15" CMP EXCAVATION DECK DRAINS (TYP.) 8"x6" SLOTS ON Cl END TIP PROJECT BR -012 -L- POT STA. 17 +80.00 O DEBBIE G. STEELMAN WETLAND PERMIT IMPACT SUMMARY WETLAND IMPACTS SURFACE WATER IMPACTS Site No. Station (From/To) Structure Size / Type Permanent Fill In Wetlands (ac) Temp. Fill In Wetlands (ac) Excavation in Wetlands (ac) Mechanized Clearing in Wetlands (ac) Hand Clearing in Wetlands (ac) Permanent SW impacts (ac) Temp. SW impacts (ac) Existing Channel Impacts Permanent (ft) Existing Channel Impacts Temp. (ft) Natural Stream Design (ft) 1 14+36.75 / 15+78.25 1 @ 40'(21" CORED SLAB) 1@60' (24" CORED SLAB), 1 @40' (21" CORED SLAB) - OAL = 142.5', IMPACTS FROM TURBIDITY CURTAINS 0.02 5* 1 14+36.75 / 15+78.25 1 @ 40'(21" CORED SLAB) 1@60' (24" CORED SLAB), 1 @40' (21" CORED SLAB) - OAL = 142.5', IMPACTS FROM STREAMBANK STABILIZATION 0.01 51 2 14+34.33 / 14+89.02 TRIBUTARY RUNNING THROUGH 48" CMP, IMPACTS FROM STREAMBANK STABILIZATION AT OUTFALL 0.02 63 TOTALS: I 1 0.03 1 0.02 1 114 1 5 *TEMPORARY IMPACTS LENGTH TOTAL = 56' (51' TAKEN INTO ACCOUNT IN PERMANENT STREAMBANK STABILIZATION IMPACTS) ATN Revised 3/31/05