HomeMy WebLinkAboutNCGNE1039_COMPLETE FILE - HISTORICAL_20141210STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. DOC TYPE HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ ao)y J I b YYYYMMDD VIA CERTIFIED MAIL 4 7013 0600 0001 1481 7102 Purdue Pharmaceuticats L.P. 4701 Purdue Drive Wilson, NC 27893 wmvpurduepharma.00m JL;3D December 1, 2014��� ��� North Carolina Department of Environment and Natural Resourccw DHNR OMw Stormwater Permitting Unit Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 Subject: Purdue Pharma Manufacturing L.P. 5235 International Drive Durham, NC 27712 No Exposure Certification To Whom It May Concern: Enclosed, please find a completed No Exposure Certification for the Purdue Pharma Manufacturing L.P. facility located in Durham, North Carolina. This facility is currently under construction. A Certificate of Occupancy is expected in May 2015. If you have any comments or questions please feel free to contact me at (252) 265-1680. Sincerely, Adam S. Postyn, CSP, CHMM Associate Director, Environmental, Health & Safety Purdue Pharmaceuticals L.P. Enclosures D NC MRP400'qW1oat* 7T Dedicated to Physician and Patient fi f :f:3U s ;.VAK) I&r ovelss+,13C Ovs i SOS U 1 tiny � WA Division of Water Quality / Surface Water Protection NCDENR National Pollutant Discharge Elimination System NORM CAMOue."[vurtMEMr OF NO EXPOSURE CERTIFICATION for Exclusion ENVIRONMENT ME NMURw REIII NCGNE0000 NO EXPOSURE CERTIFICATION National Pollutant Discharge Elimination System application for exclusion from a NO EXPOSURE: FOR AGENCY USE ONLY Dais Received ear Monlh Day cnificale ofcovenge NICIGN F DEC 0 6 2014 Permit based on Submission of this No Exposure Certification constitutes notification that your facility does not requrr for stormwater discharges associated with industrial activity in the State of North Carolina because it qualifies for a no exposure exclusion. A condition of no exposure at an industrial facility means all industrial materials and activities are protected by a storm resistant shelter (with some exceptions) to prevent exposure to rain, snow, snowmelt, and/or runoff. For permitted facilities in North Carolina, DWQ must approve your application for No Exposure Certification before this exclusion is effective. Until you are issued a No Exposure Certification and your NPDES permit is rescinded, your facility must continue to abide by the terms and conditions of the current permit. Industrial materials or activities include, but are not limited to: material handling equipment or activities, industrial machinery, raw materials, intermediate products, by-products, final products, or waste products. Material handling activities include the storage, loading and unloading, transportation, or conveyance of any raw material, intermediate product, final product or waste product. A storm resistant shelter is not required for the following industrial materials and activities: drums, barrels, tanks, and similar containers that are tightly sealed, provided those containers are not deteriorated and do not leak. "Sealed" means banded or otherwise secured and with locked or non -operational taps or valves; adequately maintained vehicles used in material handling; and final products, other than products that would be mobilized in stormwater discharges (e.g., rock salt). A No Exposure Certification must be provided for each facility qualifying for the no exposure exclusion. In addition, the exclusion from NPDES permitting is available on a facility -wide basis only —not for individual outtalls. If any industrial activities or materials are, or will be, exposed to precipitation, the facility is not eligible for the no exposure exclusion. By signing and submitting this No Exposure Certification form, you certify that a condition of no exposure exists at this facility or site and are obligated to comply with the terms and conditions of 40 CFR 122.26(g). You are reauired to For questions, please contact the DWQ Regional Office for your area. (See page 6) (Please print or type) 1) Mailing address of owner/operator (address to which all certification correspondence will be mailed): Name Purdue Pharmaceuticals L.P. Contact Adam Poston Street Address 4701 Purdue Drive City Wilson State NC ZIP Code 27893 Telephone No. (252) 265-1680 Fax: (252) 265-1656 Email adam.postvn(d)pharma.com Page 1 of 7 ITn7j] 0 2014 NC DENR Raleigh Reglonet OMios SWU-NE-12Aug2010 �i N• ii7is ,�✓, NCGNE0000 No Exposure Certification 2) Location of facility producing discharge: Facility Name Purdue Pharma Manufacturing L.P. Facility Contact Adam Poston Facility Street Address 5235 International Drive City Durham State NC ZIP Code 27712 County Durham County Telephone No. (252) 265-1680 Fax: (252) 265-1972 Email adam.postynr7a pharma.com 3) Physical location information: Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). From Durham, 85 North to exit 182 (Red Mill Road). Turn left onto Red Mill Road. In 3.7 miles. turn left onto Teknika Parkway. In 0.6 miles. turn left onto Old Oxford Road. Take the first riaht on International Drive. Purdue Pharmaceuticals will be at the end of the road (see attached mao). (A copy of a map with the facility clearly located on it should be included with the certification application.) 4) Is the facility located on Native American Lands? ❑ Yes X No 5) Is this a Federal facility? ❑ Yes X No 6) Latitude (North): 36' 6' 9.00", Longitude (West): 780 50' 51.00" (deg., min., seconds) 7) This NPDES No Exposure Exclusion application applies to which of the following: X New or Proposed Facility ❑ Existing Date operation is to begin 5/22/15 Date operation began ❑ Renewal of existing No Exposure Certification Certification No.: NCGNE 8) Was this facility or site ever covered under an NPDES Stormwater Permit? ❑ Yes X No If yes, what is the NPDES Permit Number? NA Standard Industrial Classification: Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code:2834 9) Provide a brief description of the types of industrial activities and products produced at this facility: The industrial activities performed at the facility will involve the production of solid dose pharmaceuticals. 10) Does this facility have any Non -Discharge permits (ex: recycle permits)? X No ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: 3 �' oq S5`I A , 1F. �Y'1 ? q 7 Page 2 of 7 SWU-NE-Mug2010 NCGNE0000 No Exposure Certification Exposure Checklists (12. - 14.) 11) Are any of the following materials or activities exposed to precipitation, now or in the foreseeable future? (Please check either "Yes" or "No.") If you answer "Yes" to any of these items, you are not eligible for the no exposure exclusion. a. Using, storing, or cleaning industrial machinery or equipment, and areas where ❑ Yes X No residuals from using, storing or cleaning industrial machinery or equipment remain and are exposed to stormwater b. Materials or residuals on the ground or in stormwater inlets from spills/leaks ❑ Yes X No c. Materials or products from past industrial activity ❑ Yes X No d. Material handling equipment (except adequately maintained vehicles) ❑ Yes X No e. Materials or products during loading/unloading or transporting activities ❑ Yes X No f. Materials or products stored outdoors (except final products intended for outside ❑ Yes X No use [e.g., new cars] where exposure to stormwater does not result in the discharge of pollutants) g. Materials contained in open, deteriorated or leaking storage drums, barrels, tanks, ❑ Yes X No and similar containers h. Materials or products handled/stored on roads or railways owned or maintained by ❑ Yes X No the discharger i. Waste material (except waste in covered, non -leaking containers [e.g., dumpsters]) ❑ Yes X No j. Application or disposal of process wastewater (unless otherwise permitted) ❑ Yes X No k. Particulate matter or visible deposits of residuals from roof stacks and/or vents not ❑ Yes X No otherwise regulated (i.e., under an air quality control permit) and evident in the stormwater outflow I. Empty containers that previously contained materials that are not properly stored ❑ Yes X No (i.e., not closed and stored upside down to prevent precipitation accumulation) m. For any exterior ASTs, as well as drums, barrels, tanks, and similar containers ❑ Yes X No stored outside, has the facility had any releases in the past three (3) years? 12) Above Ground Storage Tanks (ASTs): If you answer "No" to any of the following items, you are not eligible for the no exposure exclusion. a. Are exterior ASTs and piping free of rust, damaged or weathered coating, pits, or deterioration, or evidence of leaks? b. Is secondary containment provided for all exterior ASTs? If so, is it free of any cracks, holes, or evidence of leaks, and are drain valves maintained locked shut? X Yes ❑ No ❑ N/A X Yes ❑ No ❑ N/A Page 3 of 7 SW U-NE-12Aug2010 NCGNE0000 No Exposure Certification 13) Secondary Containment: If you answer "No" to any of the following items, you are not eligible for the no exposure exclusion. a. Is secondary containment provided for all single above ground storage X Yes ❑ No ❑ N/A containers (including drums, barrels, etc.) with a capacity of more than 660- gallons? b. Is secondary containment provided for above ground storage containers stored X Yes ❑ No ❑ N/A in close proximity to each other with a combined capacity of more than 1,320- gallons? 3,000 gallon fuel tank for the back-up generator has secondary containment. c. Is secondary containment provided for Title III Section 313 Superfund X Yes ❑ No ❑ N/A Amendments and Reauthorization Act (SARA) water priority chemicals*? d. Is secondary containment provided for hazardous substances** designated in 40 X Yes ❑ No ❑ N/A CFR §116? e. Are release valves on all secondary containment structures locked? Note: Site ❑ Yes ❑ No X N/A does not have any outside secondary containment structures requiring the release of precipitation. Secondary containment for inside containers consists of containment without release valves double walled tanks and storage of drums on spill pallets. 14) Hazardous Waste: a. Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? ❑ Yes X No b. Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste ❑ Yes X No generated per month) of hazardous waste? c. Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste X Yes ❑ No generated per month) of hazardous waste? When operations begin, the site will likely be a Large Quantity Generator If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: Various laboratory waste from QC lab and Isopropyl Alcohol waste How is material stored: In closed containers in the containment building with secondary containment Where is material stored: In a containment building attached to the building with secondary containment How many disposal shipments per year: 6 on average Name of transport / disposal vendor: Veolia Environmental Services Vendor address: 2176 Will Suitt Road, Creedmore, NC 27522 Footnotes to Questions 14) c. & d. Page 4 of 7 SW U-NE-12Aug2010 NCGNE0000 No Exposure Certification 'Note that amounts below the 660-gallon (single) and 1,320-gallon (combined) bulk storage minimums require secondary containment. However, some exceptions may be made for de minimis amounts of certain substances, and/or other qualifiers, as described in the exemptions from reporting requirements of Title III SARA 313 in 40 CFR §372.38. "Note that amounts below the 660-gallon (single) and 1,320-gallon (combined) bulk storage minimums require secondary containment. However, some exceptions may be made for amounts less than the Reportable Quantities of the hazardous substances listed in 40 CFR §117.3. 15) Other information: If you answer "Yes" to any of the following items, you might not be eligible for the no exposure exclusion. A more in-depth evaluation of the site circumstances may be required. a. Does your facility store used, recycled, or otherwise reclaimed pallets outside? b. Does your facility have coal piles on site? c. Does your facility store other fuel sources outside in piles, such as wood chips, sawdust, etc.? d. Does your facility have air emissions associated with its industrial activity (e.g., degreasing operations, plating, painting and metal finishing)? If so, describe the industrial activity. e. If you answered yes to d., are those emissions permitted by an Air Quality Permit? Please specify: f. Please list any other environmental program permits (federal, state, etc.) not specified earlier in this application (such as Hazardous Waste Permits, etc.): Permit: Program: Permit: Program: Permit: Program: Permit: Program: Permit: Program: Permit: Program: Permit: Program: ❑ Yes X No ❑ Yes X No ❑ Yes X No ❑ Yes x No ❑ Yes ❑ No X N/A Page 5 of 7 SWU-NE-12Aug2010 NCGNE0000 No Exposure Certification 16) Certification: I certify under penalty of law that I have read and understand the eligibility requirements for claiming a condition of "no exposure' and obtaining an exclusion from NPDES stormwater permitting. I certify under penalty of law that there are no discharges of stormwater contaminated by exposure to industrial activities or materials from the industrial facility or site identified in this document (except as allowed under 40 CFR 122.26(g)(2)). I understand that I am obligated to annually self re -certify No Exposure and, if requested, submit the re -certification to DWQ or the operator of the local municipal separate storm sewer system (MS4) into which the facility discharges (where applicable). I understand that I must allow the North Carolina Division of Water Quality, or MS4 operator where the discharge is into the local MS4, to perform inspections to confirm the condition of no exposure and to make such inspection reports publicly available upon request. In the event that the site no longer qualifies for a No Exposure Exclusion, I understand that I must obtain coverage under an NPDES permit prior to any point source discharge of stormwater from the facility. Additionally, I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is to the best of my knowledge and belief true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Title: Vice President (Signature of r19 i1%JJ stO r/-( ( ate Si ned) Please note: This application for the No Exposure Exclusion is subject to approval by the NCDENR Regional Office prior to issuance. The Regional Office may inspect your facility for compliance with no exposure conditions prior to that approval. The Regional Office may also inspect your facility at any time in the future for compliance with the No Exposure Exclusion. North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document fled or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental Management) Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). There is currently no fee for a No Exposure Exclusion. Page 6 of 7 SWU-NE-12Aug2010 NCGNE0000 No Exposure Certification Final Checklist This application should include the following items: X This completed application and all supporting documentation. X A map with the location of the facility clearly marked. X If the site currently has an NPDES Stormwater Permit, be sure to indicate the permit number in Question 8. Mail the entire package to: Stormwater Permitting Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Note The submission of this document does not guarantee the issuance of a No Exposure Exclusion. For questions, please contact the DWQ Regional Office for your area. DWQ Regional Office Contact Information: Asheville Office ...... (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ...(252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office ......... (919) 807-6300 Page 7 of 7 SWU-NE-12Aug2010 V ! (%1 ' U� , o l L�? C��i '��� �llri�,h. ; �-S=•'��`-y�T-� 7� / Q -k C p `\ g,8.'. �o��\.. 'd.' L�' '�`.-' ''�� 1 { 1 � ,, :a,lJ;�"� s �'�`l4l �C� '`� � �\I;.:. p// ,1 '�..< .• 1 4� <°, �—� �`��l4, (�'y, /'-.I ;�,:��. ni��)�/! r'�'j+� � +,�•�1�� j �J`� wr�: ti, �'� ����� '��uC ,.'}1(`�,i� IS ,�� r-1� ,�., x =• • -—I`"ll.�v I �. toikea .:5� , x ' `.' rtic ;v-1 ,./ N� lr` � �L - , �T��e yam' � ,j � � , -i �• \ ? ' •' P .,Ij l 1 l ��t�ii� l � .:�:. - z �- jam` lh(i/ ^ - % h` , , �i�',� �` '�' y .•8 �Jt 'till 0"T �'1 4�f1 �l','��� ,., yl`,ay�nn+�i.'.�• �kf���'J�Z�� I.n�es.l���� �-n �.n, \\�v F `��� �\`�'(t•� i�s � ��`�. n ��_�, l� . —.. (j�� 4 -1 �.'�. � ` ` �t ((�� ifs'. _Y�, :� �` _-r �F � l� t �•___y_I ��`, �� 1` _�_ __ ,= � \EU56 # ATE ' A! �S V � i• -i M 1 ~mil l'r"O �})J--•�rMO� in �k�. �� • � S "� [ / l µ� wit j(L � �•yf I `91 [ ' ' a i f u 1 r�..l }, .—"f' �i{ �n�,i' .- . Vl-'3 -^-0-�.� q SUBJECT PROPERTY 4731 Old Oxford Road UFt.S URS C-Mon„on - North Caman0 1600Perii" c rPa° D""r .11 .' mill"'V"nh ofi.. s6n SITE LOCATION FILE NO. 31829210 Durham, North Carolina Tdmhnn,(919)J6141M F—(919)461-1413 MAP FIG. NO. 1 Sale Source: Date: n1a M Topo.com oA117113 p i R SECURITY FENCE (SEE DETAIL SHEET C600) m \ x CO. \\ I YNERATO \ 30' DUKE POWER EASEMENT x TRANSFORMER TYR STEEP VES /:• � SYORMW�ER? MANAGEMENT / / l / FACILITY K POND MAINTENANCE & ACCESS EASEMENT BUFFER'C' _ (25' UNDISTURBED NATURAL BUFFER) \� / \ \ %30' SIDE YARD �\ \ N/F ` \\ 1THERN RESEARCH INSTITUTE \ PIN: 0845-04-45-2272 \ E: IND/INDUSTRIAL (UNDIFF) ` ZONING: IL TIER: SUBURBAN 30' SIDE YARD N/F MERCK & CO INC PIN: 0845-02-58-9 USE: IND/PHARMACEUDICj ZONING: IL TIER: SUBURBAN PROJECT SIGNAGE \� J EX. 6' ASPHALT GREENWAY TRAIL EXISTING INTERNATIONAL DRIVE (70' PUBLIC R/W) W W RELATION OF WATER MAINS TO SEWERS 1. WATER MAINS SHALL BE LAID AT LEAST 10 FT. LATERALLY FROM EXISTING N W W W W OR PROPOSED SEWERS, UNLESS LOCAL CONDITIONS OR BARRIERS PREVENT A _t pM� ... 10 FT. LATERAL SEPARATION, IN WHICH CASE: y A. THE WATER MAIN IS LAID IN A SEPARATE TRENCH, WITH THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 IN. ABOVE THE TOP OF THE SEWER, OR, Z ■ W W W W B. THE WATER MAIN IS LAID IN THE SAME TRENCH AS THE SEWER WITH THE / W W WATER MAIN LOCATED AT ONE SIDE ON A BENCH OF UNDISTURBED EARTH, Zil AND THE ELEVATION OF THE BOTTOM OF THE WATER MAIN AT LEAST 18 IN. l ABOVE THE TOP OF THE SEWER. CROSSING A WATER MAIN OVER A SEWER. y WHENEVER IT IS NECESSARY FOR A WATER MAIN TO CROSS OVER A SEWER, y W THE WATER MAIN SHALL BE LAID AT SUCH AN ELEVATION THAT THE BOTTOM y W W W OF THE WATER MAIN IS AT LEAST 18 IN. ABOVE THE TOP OF THE SEWER, W W UNLESS LOCAL CONDITIONS OR BARRIERS PREVENT AN 18 IN. VERTICAL SEPARATION - IN WHICH CASE BOTH THE WATER MAIN AND SEWER SHALL BE P^ CONSTRUCTED OF FERROUS MATERIALS AND WITH JOINTS THAT ARE Vl W EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FT ON EACH SIDE OF THE POINT OF CROSSING. W W J / . C. CROSSING A WATER MAIN UNDER A SEWER. WHENEVER IT IS NECESSARY y FOR A WATER MAIN TO CROSS UNDER A SEWER, BOTH THE WATER MAIN AND THE SEWER SHALL BE CONSTRUCTED OF FERROUS MATERIALS AND WITH JOINTS EQUIVALENT TO WATER MAIN STANDARDS FOR A DISTANCE OF 10 FT. ON EACH SIDE OF THE POINT OF CROSSING. A SECTION OF WATER MAIN PIPE SHALL BE / CENTERED AT THE POINT OF CROSSING. W W D. CROSSING A SEWER .LINE OVER OR UNDER A STORM DRAIN. WHENEVER IT IS / NECESSARY FOR A SEWER LINE TO CROSS A STORM DRAIN PIPE THE SEWER W W W LINE SHALL BE LAID AT SUCH AN ELEVATION THAT THE OUTSIDE OF THE SEWER LINE NEAREST TO THE OUTSIDE OF THE STORM DRAIN PIPE SHALL W y W W MAINTAIN A 24 IN. CLEAR SEPARATION DISTANCE (NCAC 2T RULES), OR THE y W y W SEWER LINE SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE OR ENCASED IN ,,��.u""""a,,�� W W w EITHER CONCRETE OR DUCTILE IRON PIPE FOR AT LEAST 5 FT. ON EITHER SIDE .. �y\ CARO W y W OF THE CROSSING PER NCAC 025 0.0305. y i UTILITY NOTES✓2I� '= W W W W y 1. WATER MAINS AND SEWER LINES PROPOSED IN THIS PROJECT ARE TO BE y / PRIVATE SYSTEMS UNLESS OTHERWISE SPECIFIED.�i� �(�iry��,•�JQv�.; W W W 2. ALL WATER AND SEWER SHALL BE INSTALLED IN ACCORDANCE WITH THE yq�c SP•`�.`,t W W W W W CITY OF DURHAM'S WATER AND SEWER CONSTRUCTION SPECIFICATIONS & �'�''�ru un��l�1�'(��) W "REFERENCE GUIDE FOR DEVELOPMENT". LATEST EDITION. W W 3. WATER MAINS SHALL BE DUCTILE IRON PIPE WITH A MINIMUM OF 36" OF W COVER. WATER SERVICE SHALL BE TYPE DUCTILE IRON PIPE. W 4. SANITARY SEWER: y -SANITARY SERVICES SHALL BE PVC SCHEDULE 40. SANITARY SEWER MAINS W SHALL BE PVC SDR 35 WITH A MIN. OF 48" COVER IN NON -TRAFFIC AREAS AND 60" COVER IN TRAFFIC AREAS. W W / -ALL SANITARY SEWER MAINS SHALL BE 8" UNLESS NOTED OTHERWISE. -SANITARY SEWER SERVICES SHALL BE 4" PVC SCHEDULE 40 AT 2.0% MINIMUM SLOPE OR 6" PVC SCHEDULE 40 AT 1.0% MINIMUM AS SHOWN ON PLANS. W CLEANOUTS SPACED AT 75'/100' MINIMUM (TYPICAL). 9 Z v W / -CLEANOUTS LOCATED IN PAVEMENT/STRUCTURAL SLAB AREAS SHALL BE N W / HEAVY DUTY TRAFFIC BEARING CASTINGS. o 5. PIPE CONNECTIONS TO EXISTING MANHOLES SHALL BE CORE DRILLED AND A, FLEXIBLE "RUBBER BOOT" INSTALLED TO CONNECT THE NEW PIPELINE TO THE MANHOLE. 6. VAULTS USED IN TRAFFIC AREAS SHALL BE HEAVY-DUTY TRAFFIC BEARING VAULTS. \ \\ \ 7. THE LOCATION OF EXISTING UTILITIES SHOWN ON THESE PLANS ARE BASED �\ \ ON FIELD LOCATIONS AND THE BEST AVAILABLE RECORDS. IT IS THE UTILITY a > co -- \\ CONTRACTOR'S CONSTRUCTION. FIELD -VERIFY ACTUAL LOCATIONS R PORTANYDSCREPANCESTOTHE ENGINEER TO w BEGINNING \ B. UTILITY AND GRADING CONTRACTORS SHALL CALL THE FOLLOWING UTILITY C�2 \ \ LOCATION SERVICES AT LEAST 48 HOURS PRIOR TO BEGINNING CONSTRUCTION: / \ NORTH CAROLINA ONE CALL - (800) 632-4949: CITY OF DURHAM - (919) a � \ \ 560-4326. xi A Z \\\\ 9. SEWER SERVICES WITH LESS THAN 1 FOOT DIFFERENTIAL BETWEEN BUILDING a - ^ F.F.E. AND CONNECTING MANHOLE TOP SHALL BE EQUIPPED WITH BACKWATER W `Z 50' NEUSE. RIVER .STREAM BUFFER L? EXISTING SANITARY SEWER OPEN CUT AT WETLAND ( 1 CROSSING. PERMITTING FOR R WETLAND IMPACTS REQUIRED. V \I \\ ,A \I W VALVE IN ACCORDANCE WITH THE NC PLUMBING CODE. 10. THE SANITARY SEWER LINES SHALL BE CONSTRUCTED OF EITHER PVC OR A a PROPOSED\ ., DUCTILE IRON, BASED. ON CITY OF DURHAM STANDARDS. THE. PIPE SHALL BE PROPERTY LINE INSTALLED IN ACCORDANCE WITH THE CITY OF DURHAM SPECIFICATIONS ANDpa a INSTALLATION REQUIREMENTS FOR THE PIPE MATERIAL SELECTED, O 11. CONTRACTOR TO COORDINATE ACTIVITIES WITH U11UTY COMPANIES INVOLVED `WW� ® IN ANY RELATED RELOCATION (I.E. POWER POLES, TELEPHONE PEDESTALS, P " WATER METERS, ETC.). A 12. PROTECTION OF EXISTING VEGETATION: AT THE START OF GRADING INVOLVING THE STRIPPING OF TOPSOIL OR LOWERING OF EXISTING GRADE AROUND A TREE, A CLEAN, SHARP, VERTICAL CUT SHALL BE MADE AT THE EDGE OF THE TREE SAVE AREA AT THE SAME TIME AS OTHER EROSION CONTROL MEASURES ARE INSTALLED. THE TREE PROTECTION FENCING SHALL BE • INSTALLED ON THE SIDE OF THE CUT FARTHEST AWAY FROM THE TREE TRUNK AND SHALL REMAIN IN PLACE UNTIL ALL CONSTRUCTION IN THE VICINITY OF W THE TREES IS COMPLETE. NO STORAGE OF MATERIALS, FILL OR EQUIPMENT AND NO TRESPASSING SHALL BE ALLOWED WITHIN THE BOUNDARY OF THE PROTECTED AREA. 13. ALL UTILITIES MUST BE INSTALLED UNDERGROUND. 14. BACKFLOW PREVENTER PERMIT REQUIRED FOR PROJECT. BACKFLOW PREVENTER INSTALLER MUST CONTACT DURHAM CROSS -CONNECTION CONTROL, DEPARTMENT OF WATER MANAGEMENT AT (919) 560-4194 TO OBTAIN PERMIT AND INSTALLATION REQUIREMENTS PRIOR TO INITIATING WORK. 15. ALL FIRE HYDRANTS AND FIRE DEPARTMENT CONNECTIONS MUST BE u PROVIDED WITH 5 INCH DIAMETER STORZ CONNECTIONS. 16. PROVIDE FIRE PLANS EXAMINER ONE COPY OF UTILITY CONSTRUCTION DRAWINGS, SHOWING UNDERGROUND PIPING LAYOUT AND ALL FIRE APPURTENANCES. PERMIT FOR INSTALLATION OF PRIVATE FIRE HYDRANTS MUST BE ISSUED BY FIRE PLANS EXAMINER PRIOR TO INSTA OF SAID FIRE HYDRANTS. � ,- IUf1U1 II O LI11(} UTILITY LEGEND D� R '„ & SUPFEP p„, �} ORE HYDRANT ASSEMBLY WATERLINEERMIT7INNE / w ORE DEPARTMENT CONNECTION (FDC) WATER SERVICE LINE ^ W `.d O 13 VATER METER SANITARY SEWER 11 VATER VALVE SEWER SERVICE LINE PIV POST INDICATOR VALVE — T — •t• EASEMENT. LINE h 100 YEAR FLOODPLAIN /\ © 6ACKFLOW PREVENTER •,�++++• • SANITARY SEWER MANHOLE W W.W W W L WETLANDS r"W'^1 • SEWER CLEAN -OUT EWER FLOW DIRECTIONROW _ WETLAND BUFFER e.. D PRORRC'1' No. PPH-13010 CrrY of DURHAM PPH13010—OAU1 PUBLIC WORKS DEPARTMENT ENGRCMWJNG: _ STORM HATER _ TRANSPORTATION APPROVED DEC 0 IU14 nERGISI O BY: MJES DATE ; ";. DRAWN BY: RLU DATE NC DENR Ralelgh RegWd P02-17-20141 DATE GRAPHIC SCALE DATE 100 0 50 100 200DATEI inch = 100 ft S FINAL DRAWING — RELEASED FOR CONSTRUCTION r EXISTING .� PROPERTY LINE +f+f \+\ YARD DE \ \ \ \ f \ N/F +\. BUFFER 'A' - \ MERCK & CO INC /+f + (25' UNDISTURBED \ \ r NATURAL BUFFER PIN: 0645-02-58-9335 + ) \ \ USE: IN0/PHARMG., IL CAL-HLTH f + \ \ ZONING: IL +f+ \ \ \ ♦ TIER: SUBURBAN D \ f \+ \ + f+ 12" 45'.BEND \ / 12" 45'.BEND \ R W y FIRE HYDRANT / + +�+ \ \\ \ ♦ j R I \ SECURITY FENCE (SEE N { DETAIL SHEET C600) •��• \ / / \ ~� + \\ \ \ 3 x / / x �✓ `'�za -,• i, '• x/x / / EX SSMH STORMWATER C / ?f 'm "� xv r'z'`m'' .>r °r i�x� / / ` MFACILITTYEBT Y 1,^'\� \ t.y` � �'��,� T ` ✓,_''> `� � ,�• ems,--,��� -,fis 0 f POND MAINTENANCE � � ` \\ / / '✓ � \ `° '` X < r,�K*'•i->'., -, x & ACCESS EASEMENT le 45, BEND I \ x r "'` x.k :,k ,�.' r e.�\\\ , 1141 — x - �. t'' rr -,? s •< a 64q ^, `✓Z-G tit 'Sr "'si r,',t. \ �.� }/ t � � s 7>�.�t ✓ , c n x ✓ -: ht Y'*s`.; 3�'"r > x J.+sS3r'Y'�..�n��"+ '�.,'-'',.* � z"" `y�,a \ \ \ � � / / / \\ VT •. s ,� � � x t� ->c 's � �`,'•�. ,. opt �.� �Y '�,�.� ,�,` SECURITY FENCE (SEE gyp py. �yy�j .z { • .. �.� ... / ,:N!• L.''iMy+'wiT �Y� /5 4 fr}'"•y3a£liw:'t i„ k •.t K'� Yl y•£'i �'. .i" ) DETAIL SHEET C600 / } ' r <}"'. a ,� �+r y `•' n„-.`w` '+a' t<3-^-v. r rs. e" aas�-�`�-';�SS `y4' r / �L V/ �l/ V/ x a"5 v s- ' r i �' -'Ls .q'•-29'ay..x�', 'ems-w'f Y".;'.' ..n.ta.s " %�-�X_'--X \ % X�-X—X_-X_X—XL __X—.K—X�"- / / \ \ 25' WETLAND / w \L \. \ BUFFER \ " ) FIRE HYDRANT �L � �L �L � � \V } e�• . ASSEMBLY �",r ' 3 ` ' ^" r`" %r✓"a-^'mom,'',. z,x`* v.:::r`.� ' I / / EX. WETLANDS / (TYP)r.av ,: {ham �} cx •Tr ,. a' +°`.'.k`' !t`^'�'` °,Y-"aE `' cSr ,,„r :r x-*.i.r�' x / GILDING `-..yz `-z`-zr",���Nb�.Y' CURITY BUILDING :T, '�•'t•fs- "�.., t 5'.CONCRETE tF \ x t�$ ,,. z. .z �" +..s'� ", vs'. - ra`T,.x 1`-`;a"�...� sr�a �.::"�`& .SIDEWALK/ EX SSAIH x \�� � V .i i 1 y.,.-r L R '.Y✓.. `l'N '"• 5�`{�{e ��3� ..0 a� 'a n✓ � �' \( CL.ENd � � ]�L .. � f T OUT (TYP) eiT"a-.-r,- 20' POND MAINTENANCE ELECTRICAL PRIMARY \ , r s r r�.'�F�ra ., .., f, s.m I \..4' �'ssr�ti u'•y*b.., nr..�.-a.F4-x ` l &ACCESS EASEMENT Jf �Ir 326.40 �� ay g � •. �u syx�=T�S?� <$ s' ,C"i„�? sL,'Er i a z Tt �'--- f � � / 1. �i x \ \ \ \ d f a s r s �-• 3 e r of ,�`` '.'r.3-tiny,„, , rc.- -.f+ vzc3 r "f / ' �V w j 41r\ • / t0,x a �.�yk u'y$r'-`wg'.*e.'srn''Ys .�.,,rs"` FIRE HYDRANT / .,y ,a 1 "v "a''rcr .€K t {--s"`r. ..-� - ASSEMBLY (TYP) / / YAROSTREET -\ / ` x Cf r r`. r r 't r,' ° r-�„ s, ,av ,y. 4+2,r. a�1 i- xs. r'^„ 3'�'�c`' ' / / Y `� \ \ \ f' `� r -,. r .s.~; rn��. _,Y '<5 - "�_-:. ,r`�-• = ifs'' 3✓ ,y+ `>'>4xv- a !„ +a,-, v lc .,r�4 / PROPERTY LINE ' PROPOSED \ ()r \ '•` a- sf Ftn .s* �."° e'`.'1'Y5°"`'�`sl,_A"-"-n,`4r k-Yy=y s`r,"yti'.�-'wr r,.y.,C / / / t x `f' �'s„ x S: --Y s „t 7 I £ ue�.;:` t•, �Y a „y,.a=x->2. "" ��y.+fr r. ".lr�"" wg° 5 y'v '- 3 / _ / — — — — — _ ✓ !4[� r "F l a� `;� KS :�•5,. ..F yx..: " . C � I / / y W r'3 (t.. GV ''' 1N .:rF ,� ✓> .irr�c.. ter'' -:..i / f...�� /� 30' DUKE POWER x , } EASEMENT 12" 4b' BEND Cy lr r tea.. '' .,tic' �"'yjs�-s��3' `+,., rS' 3'z ' rt'rs3'•.�r" i s q C / / GO 10 �' -r, i.'Ia - '+e ; r gxx. s w~ ry -3 i, ^'ks3ra'X-.iKam.., t e s •„ .,•x e ,s m .r y, sH- � / ' �L I { EX. SANITARY SEWER + INV.325.60 •� ,r �.✓7zr "`.;, c >° ..�. ?. ,�'J .i.:-w° s} .i�w az ,'a3="vrs �.,„,�.a`s' .2{` xu ` �, na ,WrE7s;' r s '."; 1 / /f 08. 1223 PG. LAbLMtN I' D 39Ti UNKNOWN 12•X6" TEE +.< e r r, w . p+£-. +«x, ts�.�-rnr r ,r,-.,t` t, `' r e..� DB. 1510 PG. 958 j ° '" ti ate- :[ ry,3sl r,'' r�.er�.t k''V f'. < •s,. +5'>n tr„ :. skn p / 12o 9 TEE EX SSMH + ro 9 g^ i � 'tip" cF P t,m,}. 'S�^ ,: INV­328.12 3 r r r ,k,.. t spn r,.. wet � } =.-. t,..T�'rs�,. S ' a. v : ,,, y l_ / l +/ �B $ INV-325.03 ..-- �, / POND MAINTENANCE , r '� '— v ' -S.y tr k.r- ::`'"� '"E'z r i * k ' I •( • /j \ / / i % &ACCESS EASEMF1d� / .. , ` \ a 12' 45' KENO @q� - .'. r a..- �` x� s. �x. {i' Y^+ } .FS " 1 //�/ \ I / TREYBURN CORPORATE PARK LLC \ rr , r 12" 22.5 BEND C. J • PIN: 0845�04�64-0807 / / / \ \ " P� 5$ZRA / // / I ZONING: IL 12 45' BEND USE: VACANT INDUSTRIAL � / ' TIER: SUBURBAN \ $S INV= • ' f DECORATIVE SECURITY // / `I' Jr Ji w /� �L / \ .• r ` : ,� z 50' NEUSE RIVER + / / OJr: \ . ' 4"" "z / STREAM BUFFER / MT GEMENT , , , 324.00 r �-% _ /"� FENCE (SEE DETAIL / /+/ / /• / FACILIA' A i SSMH 7 ,r > x arya' v .• J /.. SHEET C600)/J� C _ / /MATCHUNE SHEET C402 y / o 8 NOTE $ 1. CLEANOUTS LOCATED IN PAVEMENT/STRUCTURAL SLAB AREAS SHALL BE UTILITY LEGEND CITY OF DURHAM PUBLIC BgRlI.4 DEPARTMENT FIRE HYDRANT ASSEMBLY WATERLINE s HEAVY DUTY TRAFFIC BEARING CASTINGS. APPROVED WATER SERVICE LINE Y FIRE DEPARTMENT CONNECTION (FDC) ENGINEERING: DATE O WATER METER SANITARY SEWER STORM WATER DATE � N WATER VALVE SEWER SERVICE LINE TRANSPORTATION DATE PIV POST INDICATOR VALVE -- EASEMENT .LINE © El.,..•= 100 YEAR FLOODPLAIN c DATE BACKFLOW PREVENTER 5 oDATE SANITARY SEWER MANHOLE W "W W WETLANDS SEWER -OUT r >���• SEWER FLOW NDIRECTION WETLAND BUFFER ARROW GRAPHIC SCALE 50 0 25 50 100 In ?d111 1 inch 50 It - FINALDRAWING — RELEASED FOR CONSTRUCTION PROJWT NO. PPH-13010 FUMNAMR: PPH13010—U1 DMGN O BY. MJES SCALE: 1 "=50' Der& 02-17-2014 S!$ET N0. C 4 01. 'JI MCADAMS NC DENR Raleigh Regional Office r;