Loading...
HomeMy WebLinkAboutNCGNE0880_COMPLETE FILE - HISTORICAL_20111110I ?/o STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /V DOC TYPE da'HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ t7 ( O YYYYMMDD NCDENR North Carolina Department of Environment and Natural Resources Division of Water Duality Beverly Eaves Perdue Coleen H. Sullins Governor Director November 10, 2011 Mr. Francis Vega Vega Metals, Inc. 214 Hunt Street Durham, North Carolina 27701 Subject: No -Exposure Certification NCGNE0808 Vega metals, Inc. Durham County Dear Mr. Vega: Dee Freeman Secretary The Division has reviewed your submittal of the No -Exposure Certification for Exclusion from NPDES Stormwater Permitting form and made site visits to assess the potential for stormwater pollution. Based on our observations and your submittal and signed certification of no exposure at the above referenced facility, the Division is granting your conditional exclusion from permitting as provided for under 40 CFR 126.22(g), which is incorporated by -reference in North Carolina regulations. Please note that by our acceptance of your no -exposure certification, you are obligated to maintain no -exposure conditions at your facility. If conditions change such that your facility can no longer qualify for a no -exposure exclusion, you are obligated to immediately obtain NPDES permit coverage for your stormwater discharge. Otherwise, the discharge becomes subject to enforcement as an un-permitted discharge (subject to civil penalties of up to $25,000 per day). Your conditional no -exposure exclusion does not expire. However, you must self re- certify annually using the enclosed form, or obtain NPDES permit coverage for any stormwater discharges from your facility. Please store the completed re -certification forms in order to have them available during future inspections by DWQ. Your conditional exclusion from permitting does not affect your facility's legal requirements to obtain environmental permits that may be required under other federal, state, or local regulations or ordinances. If you have any questions or need further information, please contact Dave Parnell at (919) 791-4200 or at david.parnell@ncdenr.gov. OS�mely, i7 L r2,l for Coleen Attachment: cc: RRO County NE File Durham County Stormwater Permitting Unit Stormwater Permitting Unit No -Exposure Files North Carolina Division of Water Quality 1628 Mail service Center Raleigh, NC 27699-1628 Phone (919) 791-4200 Internet: www. ncwatercualitv.org Location: 3800 Barrett Drive Raleigh, INC 27609 Fax (919) 788-7159 An Equal Opportunity/Affirmative Action Employer— 50 % Recycled/10% Post Consumer Paper IC NorthCarolina Customer Attimallf 1-877-623-6748 No -Exposure Self Re -Certification Information: You are obligated to maintain no -exposure* conditions at your facility. If conditions change such that your facility can no longer qualify for a no -exposure exclusion, you are obligated to immediately obtain NPDES permit coverage for your stormwater discharge. Otherwise, the discharge becomes subject to enforcement as an un-permitted discharge. State statute provides for fines of up to $25,000 per day for un-permitted discharges. Your conditional no -exposure exclusion must be self re -certified at least annually as follows: - Complete the re -certification at a minimum of once per year using the included Self Re - Certification Form. (additional copies can be downloaded from http://portal.ncdenr.org/web/wq/ws/su/npdessw#tab-5 ) - Maintain a record of re -certifications on file at the facility. Do not submit the re -certification to DWQ unless requested. If requested, submit a copy of the re -certification to the Division and/or the municipality in which the facility is located. -During an inspection by DWQ or local government, provide the re -certifications immediately upon request. - Notify the Division of any changes in ownership, significant facility and/or activity changes, or if the facility can no longer maintain no -exposure. -Allow the NPDES permitting authority or, if discharging into a municipal separate storm sewer system, the operator of the system, to: (1) inspect the facility; and (2) make such inspection reports publicly available upon request. * "No exposure" means that all industrial materials and activities are protected by a storm resistant shelter to prevent exposure to rain, snow, snowmelt, and/or runoff. Industrial materials or activities include, but are not limited to, material handling equipment or, activities, industrial machinery, raw materials, intermediate products, by-products, final products, or waste products. Material handling activities include the storage, loading and unloading, transportation, or conveyance of any raw material, intermediate product, final product or waste product. (40 CFR 122.26(g)) Information and forms related No -Exposure Certifications can be accessed on the website at: http://portal.ncdenr.org/web/wq/ws/su/npdessw#tab-5 Permit: NCGNE0808 Effective: SOC: Effective: County: Durham Region: Raleigh Contact Person: Francis Vega Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Compliance Inspection Report Expiration: Owner: Vega Metals Inc Expiration: Facility: Vega Metals Inc 214 Hunt St Title: Inspection Date: 11/01/2011 Entry Time: 02:00 PM Primary Inspector: David R Parnell Secondary Inspector(s): Durham NC 27701 Phone: 919-688-8267 Certification: Exit Time: 02:30 PM Phone: Phone: 919-791-4260 Reason for Inspection: Routine Inspection Type: Technical Assistance Permit Inspection Type: Stormwater Discharge, No Exposure Certificate Facility Status: ■ Compliant ❑ Not Compliant Question Areas: 0 Miscellaneous Questions NMisc (See attachment summary) Page: 1 r Permit: NCGNE0808 Owner - Facility: Vega Metals Inc Inspection Date: 11/01/2011 Inspection Type: Technical Assistance Reason for Visit: Routine Inspection Summary: A site visit on October 11, 2011 revealed metals that were being exposed to stormwater runoff. The metals were being stored at the rear of the facility. The dumpster had metal waste being exposed to the elements while being waiting to be hauled away and recycled. An opportunity was given to the facility to correct the storage of materials issue and implement BMPs to become eligible for the Certificate. Samples of stormwater were taken and the storage area were within benchmarks, the dumpster area had elevated lead readings. BMPs as well as removal of an old generator and other metals were implemented. A removable lid for the dumpster was inspected on November 2 and approved.. Based on the sample results, increase in BMPs and removal of metals from exposed stormwater the Certificate for No Exposure is granted to this facility. Misc Is the facility compliant? Comment: Yes No NA NE Page:2 7 :W INWA Division of Water Quality / Surface Water Protection Ax ® NC®ENR National Pollutant Discharge Elimination System NO EXPOSURE CERTIFICATION for Exclusion NCGNE0000 NO EXPOSURE CERTIFICATION FOR AGENCY USE ONLY Dale, Received Ycur Manih Duy Certificate of Covemgc NICIG IN[PR D8 National Pollutant Discharge Elimination System application for exclusion from a Stormwater Permit based on NO EXPOSURE: Submission of this No Exposure Certification constitutes notification that your facility does not require a permit for Stormwater discharges associated with industrial activity in the State of North Carolina because it qualifies for a no exposure exclusion. A condition of no exposure at an industrial facility means all industrial materials and activities are protected by a storm resistant shelter (with some exceptions) to prevent exposure to rain, snow, snowmelt, and/or runoff. For permitted facilities in North Carolina, DWQ must approve your application for No Exposure Certification before this exclusion is effective. Until you are issued a No Exposure Certification and your NPDES permit is rescinded, your facility must continue to abide by the terms and conditions of the current permit. Industrial materials or activities include, but are not limited to: material handling equipment or activities, industrial machinery, raw materials, intermediate products, by-products, final products, or waste products. Material handling activities include the storage, loading and unloading, transportation, or conveyance of any raw material, intermediate product, final product or waste product. A storm resistant shelter is not required for the following industrial materials and activities: drums, barrels, tanks, and similar containers that are tightly sealed, provided those containers are not deteriorated and do not leak. "Sealed" means banded or otherwise secured and with locked or non -operational taps or valves; adequately maintained vehicles used in material handling; and final products, other than products that would be mobilized in stormwater discharges (e.g., rock salt). A No Exposure Certification must be provided for each facility qualifying for the no exposure exclusion. In addition, the exclusion from NPDES permitting is available on a facility -wide basis only —not for individual outfalls. If any industrial activities or materials are, or will be, exposed to precipitation, the facility is not eligible for the no exposure exclusion. By signing and submitting this No Exposure Certification form, you certify that a condition of no exposure exists at this facility or site and are obligated to comply with the terms and conditions of 40 CFR 122.26(g). For questions, please contact the DWO Regional Office for your area. (Seepage 6) ' 1) Mailing address o Name Contact Street Address City AUG 2 3 P011 WETLAH SANDST0RMWATTERBPMCH SW U-N E-12Aug2010 (Please print or type) Page 1 of 7 AUG 2 9 2011 �aPelc.: °- ' nl Ofi'1Ce R NCGNE0000 No Exposure Certification 2) Locati Facility Facility Facility City County Teleph Email of facility ­,4-�^i^^ Addre No. 3) Physical location information: Please (provide a narrative description of how to get to the facility (use street names, state distance and directioq from a roadway intersection)., k/'v1/1/ %4 %�fke- (A copy of a map with the facility clearly located on it sh6uld be included with the certification application.) I 4) Is the facility located on Native American Lands? ❑ Yes �r vo 5) Is this a Federal facility? ❑ Yes 141 6) Latitude,�� qs' Longitude r79, 05 /9 (deg., min., seconds) 7) This NPDES No Exposure Exclusion application applies to which of the following: ❑ New or Proposed Facility Date operation is to begin q / W Existing Date operation began f/ r ❑ Renewal of existing No Exposure Certification Certification No.: NCGNE 8) Was thus facility or site ever covered under an NPDES Stormwater Permit? ❑ Yes 0 N// o If yes, what is the NPDES Permit Number? 9) Standard Industrial Classification: Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code:.9 z 10) Provide a brief description of t types of industrial activities and pro ucts produced at this facility: 11) Do /es this facility have any Non -Discharge permits (ex: recycle permits)? Ii-ivo ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: a 3 Page 2 of 7 SW U-NE-1 Mug2010 IR MW NCGNE0000 No Exposure Certification Exposure Checklists (12. - 14.) 12) Are any of the following materials or activities exposed to precipitation, now or in the foreseeable future? (Please check either "Yes" or "No.") If you answer "Yes" to any of these items, you are not eligible for the no exposure exclusion. a. Using, storing, or cleaning industrial machinery or equipment, and areas where ❑ Yes M o residuals from using, storing or cleaning industrial machinery or equipment remain and are exposed to stormwater b. Materials or residuals on the ground or in stormwater inlets from spills/leaks ❑ Yes c. Materials or products from past industrial activity ❑ Yes 11eo d. Material handling equipment (except adequately maintained vehicles) ❑ Yes V.Wo e. Materials or products during loading/unloading or transporting activities ❑ Yes WNo f. Materials or products stored outdoors (except final products intended for outside ❑ Yes f'No use [e.g., new cars] where exposure to stormwater does not result in the discharge of pollutants) g. Materials contained in open, deteriorated or leaking storage drums, barrels, tanks, ❑ Yes ZAK and similar containers h. Materials or products handled/stored on roads or railways owned or maintained by ❑ Yes the discharger i. Waste material (except waste in covered, non -leaking containers [e.g., dumpsters]) ❑ Yes Ip 0 j. Application or disposal of process wastewater (unless otherwise permitted) ❑ Yes VVo k. Particulate matter or visible deposits of residuals from roof stacks and/or vents not ❑ Yes V-fo otherwise regulated (i.e., under an air quality control permit) and evident in the stormwater outflow I. Empty containers that previously contained materials that are not properly stored ❑ Yes 440 (i.e., not closed and stored upside down to prevent precipitation accumulation) m. For any exterior ASTs, as well as drums, barrels, tanks, and similar containers ❑ Yes E6-No stored outside, has the facility had any releases in the past three (3) years? 13) Above Ground Storage Tanks (ASTs): If you answer "No" to any of the following items, you are not eligible for the no exposure exclusion. a. Are exterior ASTs and piping free of rust, damaged or weathered coating, pits, or deterioration, or evidence of leaks? b. Is secondary containment provided for all exterior ASTs? If so, is it free of any cracks, holes, or evidence of leaks, and are drain valves maintained locked shut? ❑ Yes ❑ No 19441A" Page 3 of 7 S W U-NE-12Aug2010 Z R NCGNE0000 No Exposure Certification 14) Secondary Containment: If you answer "No" to any of the following items, you are not eligible for the no exposure exclusion. a. Is secondary containment provided for all single above ground storage ❑ Yes ❑ No 2 /A containers (including drums, barrels, etc.) with a capacity of more than 660- gallons? b. Is secondary containment provided for above ground storage containers stored ❑ Yes ❑ No LR /A in close proximity to each other with a combined capacity of more than 1,320- gallons? c. Is secondary containment provided for Title III Section 313 Superfund ❑ Yes ❑ No I--N%A Amendments and Reauthorization Act (SARA) water priority chemicals'? d. Is secondary containment provided for hazardous substances" designated in 40 ❑ Yes ❑ No M-N/A CFR §116? e. Are release valves on all secondary containment structures locked? ❑ Yes ❑ No CAN/A 15) Hazardous Waste: a. Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? ❑ Yes M No b. Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste ❑ Yes Owe generated per month) of hazardous waste? c. Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste ❑ Yes [tYNo generated per month) of hazardous waste? If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport / disposal vendor: Vendor address: Footnotes to Questions 14) c. & d. 'Note that amounts below the 660-gallon (single) and 1,320-gallon (combined) bulk storage minimums require secondary containment. However, some exceptions may be made for de minimis amounts of certain substances, and/or other qualifiers, as described in the exemptions from reporting requirements of Title III SARA 313 in 40 CFR §372.38. "Note that amounts below the 660-gallon (single) and 1,320-gallon (combined) bulk storage minimums require secondary containment. However, some exceptions may be made for amounts less than the Reportable Quantities of the hazardous substances listed in 40 CFR §117.3. Page 4 of 7 S W U-N E-1 MugM 0 NCGNE0000 No Exposure Certification 16) Other information: If you answer "Yes" to any of the following items, you might not be eligible for the no exposure exclusion. A more in-depth evaluation of the site circumstances may be required. a. Does your facility store used, recycled, or otherwise reclaimed pallets outside? -Yes ❑ No b. Does your facility have coal piles on site? ❑ Yes ❑ No c. Does your facility store other fuel sources outside in piles, such as wood chips, ❑ Yes o sawdust, etc.? d. Does your facility have air emissions associated with its industrial activity (e.g., *1 es ❑ No degreasing operations, plating, painting and mgtal finishing)? If so, describe the industrial activity: cti Hl i 6w 7421 AI5. 'W e. If you answered yes to d., are t ose emissions ermitted by an Air Quality Permit? ❑ Yes U Fvo ❑ N/A Please specify: (tl< Aer S�_ �?�e, R 44 b �RS�r. i S 9 /4r-y�o4 f. Please list any other environmental program permits (federal, state, etc.) not specified earlier in this application (such as Hazardous Waste Permits, etc.): Permit: Program: Permit: Program: Permit: Program: Permit: Program: Permit: Program: Permit: Program: Permit: Program: Page 5 of 7 S W U-N E-12Aug2010 NCGNE0000 No Exposure Certification 17) Certification: I certify under penalty of law that I have read and understand the eligibility requirements for claiming a condition of "no exposure" and obtaining an exclusion from NPDES stormwater permitting. I certify under penalty of law that there are no discharges of stormwater contaminated by exposure to industrial activities or materials from the industrial facility or site identified in this document (except as allowed under 40 CFR 122.26(g)(2)). I understand that I am obligated to annually self re -certify No Exposure and, if requested, submit the re -certification to DWQ or the operator of the local municipal separate storm sewer system (MS4) into which the facility discharges (where applicable). I understand that I must allow the North Carolina Division of Water Quality, or MS4 operator where the discharge is into the local MS4, to perform inspections to confirm the condition of no exposure and to make such inspection reports publicly available upon request. , In the event that the site no longer qualifies for a No Exposure Exclusion, I understand that I must obtain coverage under an NPDES permit prior to any point source discharge of stormwater from the facility. Additionally, I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gathered and evaluated the information submitted. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is to the best of my knowledge and belief true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and imprisonment for knowing violations. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Please note: This application for the No Exposure Exclusion is subject to approval by'the NCDENR Regional Office prior to issuance. The Regional Office may inspect your facility for compliance with no exposure conditions prior to that approval. The Regional Office may also inspect your facility at any time in the future for compliance with the No Exposure Exclusion. North Carolina General Statute 143-215.6 B(i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsities, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). There is currently no fee for a No Exposure Exclusion. Page 6 of 7 S W U-NE-12Aug2010 W Vr NCGNE0000 No Exposure Certification Final Checklist This application should include the following items: V, This completed application and all supporting documentation. t� A map with the location of the facility clearly marked. ❑ If the site currently has an NPDES Stormwater Permit, be sure to indicate the permit number in Question 8. Mail the entire package to: Stormwater Permitting Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Note The submission of this document does not guarantee the issuance of a No Exposure Exclusion. For questions, please contact the DWQ Regional Office for your area. DWQ Regional Office Contact Information: Asheville Office ...... (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ...(252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office .........(919) 807-6300 Page 7 of 7 SW U-N E-12Aug2010 ' � r F ' 214 Hunt St, Durham, NC 27701 - Google Maps Page 1 of 1 Address 214 Hunt St +oosC maps Durham, NC 27701 Get Google Maps on your phone Text the word "GMAPS"to 466 553 ti http://maps.google.com/maps?f�—q&source=s_q&hl=en&geocode=&q=214+Huiit+St,+Dur... 8/ 16/2011 p po e Crane MID -ATLANTIC ASSOCIATES, INC. Engineering d Environmental Solutions 409 Rogers View Court/Raleigh /North Carolina 127610 800486-75681919-250-99181919-250-9950 Facsimile wwmA1AAonline.com November 1. 2011 Mr. Dave Parnell North Carolina Department of Environment and Natural Resources Division of Water Quality Surface Water Protection Section 1628 Mail Service Center Raleigh, North Carolina 27699 Subject: STORMWATER SAMPLING RESULTS VEGA METALS 214 HUNT STREET DURHAM, DURHAM COUNTY, NORTH CAROLINA MID -ATLANTIC JOB NO. OOOR2302.00 Dear Mr. Parnell: Mid -Atlantic Associates, Inc. (Mid -Atlantic) is pleased to submit the attached analytical results for the stormwater sampling conducted at the above -referenced site. Mid -Atlantic personnel mobilized to the site on October 18, 2011 and collected a representative stormwater sample from two areas of the site, labeled as Outfall 001 and Outfall 002 on the attached Site Map. The stormwater discharge at each of these locations was relatively clear with no distinct odor, color or evidence of foam, an oil sheen or significant solids. There was also no visible evidence of erosion at the site or erosion deposition at the sample locations. The stormwater samples were analyzed in the laboratory for total suspended solids (TSS), total recoverable lead and oil and grease and in the field for pH. The analytical results and pH measurements were compared to the benchmark values established in National Pollutant Discharge Elimination System (NPDES) General Permit NCG030000. With the exception of lead detected in the sample from Outfall 001, all parameters were reported below or within their respective benchmark values (see attached Table). Based on the laboratory results and our observations at the site, the lead concentration detected in the sample collected from Outfall 001 does not appear to be the result of operations at the site. It appears that the elevated lead concentration may be the result of sediment from recent grading activities (installation of a new sidewalk, placement of new gravel/crush and run) becoming entrained in the stormwater runoff. Stormwater Sampling Results Vega Metals — 214 Hunt Drive Durham, North Carolina November 1, 2011 Page 2 Mid -Atlantic appreciates the opportunity to provide you with these services. If you have any questions or need additional information, please contact me at 919-250-9918. Sincerely, MID -ATLANTIC ASSOCIATES, INC. Charles B. Hoffman Staff Geologist Attachments: Table Site Map with Outfall Locations Laboratory Analytical Report TABLE . STORMWATER SAMPLING RESULTS VEGA METALS- 214 HUNT DRIVE DURHAM, NORTH CAROLINA MID=ATLANTIC JOB NO. OOOR2302.00 OUTFALL001 OUTFALL002 BENCHMARK ' VALUEIRANGE' TSS 99.5 mg/L 17.7 mg/L 100 mg/L Oil and Grease 5.3 mg/L < 5.0 mg/L 30 mg/L Lead 4.46 mg/L 0.0016 mg/L 0.033 mg/L pH 7.5 7.6 Notes: mg/L - Miligrams per Liter ' - As defined by NPDES General Permit NCG030000 Bold values indicate concentrations exceeding the benchmark value Outfall 002 4 ea S° PAIW- Lis. mi L. ! Outfall001 r 3 'i +77"! - SG� Laboratory Report of Analysis To: Chuck Hoffman MID -ATLANTIC ASSOCIATES 409 Rogers View Court Raleigh, NC 27610 Report Number: 31102948 Client Project: Vega Metals Dear Chuck Hoffman, Enclosed are the results of the analytical services performed under the referenced project for the received samples and associated QC as applicable. The samples are certified to meet the requirements of the National Environmental Laboratory Accreditation Conference Standards. Copies of this report and supporting data will be retained in our files for a period of five years in the event they are required for future reference. All results are intended to be used in their entirety and SGS is not responsible for use of less than the complete report. Any samples submitted to our laboratory will be retained for a maximum of thirty (30) days from the date of this report unless other arrangements are requested. If there are any questions about the report or services performed during this project, please call Michael D. Page at (910) 350-1903, We will be happy to answer any questions or concerns which you may have. Thank you for using SGS North America Inc. for your analytical services. We look forward to working with you again on any additional analytical needs. Sincerely, SGS North America Inc. Digitally signed Michael Page Date: 2011.10.31 14:53:44-05'0O' Michael D. Page Date Project Manager michael.page@sgs.com Print Date. 1013V2011 N.C. Certification N 481 SGS North America Inc. 15500 Business Drive, Wilmington, NC 28405 Page 1 of 14 -gil _S_G Laboratory Qualifiers Report Definitions DL Method, Instrument, or Estimated Detection Limit per Analytical Method CL Control Limits for the recovery result of a parameter LOQ Reporting Limit DF Dilution Factor RPD Relative Percent Difference LCS(D) Laboratory Control Spike (Duplicate) MS(D) Matrix Spike (Duplicate) MB Method Blank Qualifier Definitions Recovery or RPD outside of control limits B Analyte was detected in the Lab Method Blank at a level above the LOQ U Undetected (Reported as NO or < DQ V Recovery is below quality control limit. The data has been validated based on a favorable signal-to-noise and detection limit A Amount detected is less than the Lower Method Calibration Limit J Amount detected is between the Method Detection Limit and the Lower Calibration Limit O The recovery of this analyte in the OPR is above the Method QC Limits and the reported concentration in the sample may be biased high E Amount detected is greater than the Upper Calibration Limit S The amount of analyte present has saturated the detector. This situation results in an underestimation of the affected analyle(s) Q Indicates the presence of a quantitative interference. This situation may result in an underestimation of the affected analyte(s) I Indicates the presence of a qualitative interference that could cause a false positive or an overestimation of the affected analyte(s) DPE Indicates the presence of a peak in the polychlorinated diphenylether channel that could cause a false positive or an overestimation of the affected analyte(s) TIC Tentatively Identified Compound EMPC Estimated Maximum possible Concentration due to ion ratio failure NO Not Detected K Result is estimated due to ion ratio failure in High Resolution PCB Analysis P RPD > 40% between results of dual columns D Spike or surrogate was diluted out in order to achieve a parameter result within instrument calibration range Samples requiring manual integrations for various congeners and/or standards are marked and dated by the analyst. A code definition is provided below: M1 Mis-identified peak M2 Software did not integrate peak M3 Incorrect baseline construction (i.e. not all of peak included: two peaks integrated as one) M4 Pattern integration required (i.e. DRO, GRO, PCB, Toxaphene and Technical Chlordane) M5 Other- Explained in case narrative Note Results pages that include a value for "Solids (%)" have been adjusted for moisture content. Print Date', 10/31/2011 N.C. Certification k 481 SGS North America Inc. 15500 Business Drive, Wilmington, NC 28405 Page 2 of 14 Sample Summary Client Sample ID Lab Sample ID Collected Received Matrix Outfall 001 31102948001 10/19/2011 15:30 10/21/2011 10:10 Water Outfall 002 31102948002 10/19/2011 16:00 10/21/2011 10:10 Water Print Date: 10/31/2011 N.C_ Certification d 481 5500 Business Drive, Wilmington, NC 28405 SGS North America Inc. . of n rzn r oro r of n xn r co ,...... ..,,., Page 3 of 14 SGS North America Inc, SS00 Business Drive, Wilmington, NC 2840S Page 4 of 14 5500 Business Drive, Wilmington, NC 28405 SGS North America Inc. ,,,,,,,, ,,,,,,,,.__..._______ Group Page 5 of 14 SGS North America Inc. 5500 Business Drive, Wilmington, NC 28405 Member of SGS Group Page 6 of 14 SGS, 5500 Business Drive, Wilmington, NC 28405 SGS North America Inc. ............... ............._ Page 7 of 14 SG-S, SGS North America Inc. I5500 Business Drive, Wilmington, NC 28405 Page 8 of 14 SGS North America Inc. 5500 Business Drive, Wilmington, NC 28405 Page 9 of 14 0 Page 1 of i 0 MOTEST Laboratory Report c' Lab Location Yd' !�? Lab Location 'C' Lab Location 'IP NCNVW Cen.#: 067 NC/DW Cen.#: 37731 NC1WW Ced.#: 103 NC/DW Cert.#: 37733 NCAVW Cerl.#: 075 NC/DW Cen11: 37721 6701 Conference Dr, Raleigh, NC 27607 ) 6300 Ramada Dr, Suite C2, Clemmons, NC 27012 6624 Gordon Rd, Unit G. Wilmington, NC 28411 i Ph: (919) 8344984 Fax: (919) 834-6497 h Ph: (336) 766-7846 Fax: (336) 766-2514 Ph: (910) 763-9793 Fax: (910) 343-9688 Project No.: 01 Project ID: 31102948001 & 31102948002 — Prepared for -- : MICHAEL PAGE SGS NORTH AMERICA 5500 BUSINESS DRIVE WILMINGTON, NC 28405 - Report Date: 1013112011 Dale Received: 1012412011 Work Order #: 1110-01737 Cust. Code: SGSNA Cust. P.O.: .. ., No. Sample ID Date Sampled Time Sampled Matrix Sample Type Condition .601 31102948001 1011912011 15:30 WW Grab 4+1-2 deg zed Test Performed Method Results Lab Loc Date Time Qualifier Total Suspended Solids SM 2540D 99.5 mgfL R 10125111 16:53 Oil & Grease EPA 1664A 5.3 mg/L R 10125/11 15:00 No. Sample ID Date Sampled Time Sampled Matrix Sample Type Condition 002 31102948002 1011912011 16:00 WW Grab 4+1-2 deg Test Performed Method Results Lab Loc DateyZed Time Qualifier Total Suspended Solids SM 2540D 17.7 mg/L R 10/25/11 16:53 Oil & Grease EPA 1664A <5.0 mg/L R 10124/11 15:00 Reviewed by: for Tritest, Inca. Page 10 of 14 CHAIN OF CUSTODY RECORD (o'atl" SGS North America Inc. CLIENT SGS Reference - 311 PAGE I OF 1 . CONTACT G NENO(9 to) �. 19oT .JJ No SAP r PE Nsmay .. PROJECT 31' I SITEIPWS109 1 00 N T A IN E R $ � caw A po R".w 3 y T V REMARKS REPORTS 70 S FAX NO ( ) INVOICE TO IOUOTEA PO NUMBER 2 LAB NO SAMPLE IDENTIFICATION GATE TIME MATRIX 3110*�`IN o )0 9 u i: w a 0 8 IJe3L ✓ 8 4 C011ecled/Relingwshed By (1) Date it Time ) �I ��� Received By Shipping Carrier Shipping Ticket No Samples Received Cold? (Circle) YES NO Temperaturo C Reh Awished By (2) Date Time Received By Special Deliverable Requirements Chain of Custody Seal (Circle) INTACT BROKEN' _ ABSENT Relinquished By (3) Date Time Received By Special lnsWcuons - Relinquished By (4) Date Time Received By Requested Turnaround Time ❑ RUSH i�1a0 �c161 R - ❑ STD U 200 IN Pager Drive AochOraO., AKS951B Tel (907)%2-2343 Fax (907)561,5301 05500 Bisiness Dnve Wilmington, NC 23A05 Tel (910)35 1903 Fft (910)350-1557 �' WM1Y-ReleavO Ey UC �- RYNneO P/ Geiii '� L 7ROUTEST SAMPLE PRESERVATION CHECK -IN SHEET WON ^, -ol 73 7..- . Checked in by ' Date ( d -Z.� 1'imc Tcmp (°C) Route D TTS TTPU I USM I PEDX GC UPS SamPle No. Analysis Requested Chlorine Samples Preserved Properly! Comments ` Pos / Yes No A Pos / n g Yes No A Pos /n e No N/A Pos / ne Y s No N/A Pos /neg Yes No N/A Pos/neg Yes No N/A Pos / neg Yes No N/A '- Pos / neg Yes No NIA Pos / neg Yes No N/A Pos / neg Yes No N/A Pos / neg Yes No N/A Pos / neg Yes No N/A - Pos/neg Yes No N/A Pos/neg Yes No N/A Pos / neg Yes No N/A Pos/neg Yes No N/A Pos / neg Yes No N/A -- Pos neg Yes No N/A . Pos / neg Yes No N/A .. „ Pos neg Yes No N/A Pos / neg Yes No N/A Pos / neg Yes No N/A Pos / neg Yes No N/A . - Pos neg Yes No N/A Pos /neg Yes No N/A CHAIN OF CUSTODY RECORD SGS Environmental Services Inc. Locations Nationwide •Alaska •Hawaii . Ohio • Maryland - • New Jersey • North Carolina West Yirgirua 091166 wnw.us.sgs.com LPAGEi ? PHONE NO:(4) Fj(j(,& SGS Reference: OF �1� No SAMPLE Pra .w uses Tp-LS SITE/P4VSID#: `1Z- 2312-00 C O. N T q I E R S -TYPE.' COMP GRAB Nielyeis ReyWed - O I H c Y —+ W:• . REMARKS REPORTS TO: E-MAIL: �eU7>Fc.Aa.a AIVrAOiJNNG.[ON (1. YjvFFN4M1tei FAXNO:( ) 2 INVOICETO: QUOTA# P.O. t UMBER 21.0'1, 00 LAB NO. SAMPLE IDENTIFICATION DATE TIME MATRIX m w buzFau Oo l tATG CbL t 1► 30 &eo 92,0 Fj 0 3 G 'A o_ a 4 Shipping Cartier: Shipping Ticket No: Samples Received Cold? (Cirol E NO Temperature 5 CpUected/Relinquished By:(1) / I Date �a Time Received By: Date Time Relinquished By: (2) Date Time R ed By: t Time Special Deliverable Requirements: Chain of Custody Seal: (Circle) - INTACT BROKEN SEN Relinquished By: (3) Date Time Received By: Date Time Special Instructions: Relinquished By: (4) Date Time Received By: __J Date I Time 1 Requested Turnaround Time: ❑ RUSH Needed STD Date N _. __.. _.,. ...... F__.,�. 134"oat Mks - Retained by Lab 0200 W. Potler Ortrs Anchersgs,AK99319 Tel:(W7)Se2.2343 Fex:(907)Set-5301 01270Gmenbder Street Charleeton.VP/2A11 ier.lxwl ro.n ��•��---i^_. _. ifiti ,,_„o,�„o,, ,•,......�.. Rnk-Retekfed by Sampler SGS North America Inc. Sample Receipt Checklist (SRC) ant: Mid -Atlantic Work Order No.: 31102948 1. x Shipped Notes: Hand Delivered 2, x COC Present on Receipt COC —No Additional Transmittal Forms 3. Custody Tape on Container x No Custody Tape 4. x Samples Intact Samples Broken / Leaking 5. x Chilled on Receipt Actual Temp.(s) in °C: 0.8 on Receipt _Ambient on Ice; Coming down to temp. —Walk-in Received Outside of Temperature Specifications 6. x Sufficient Sample Submitted Insufficient Sample Submitted 7. absent _Chlorine x HNO3 < 2 < 2 _HCL Additional Preservatives verified (see notes) 8. x Received Within Holding Time Received Within Holding Time —Not Pb 3030C out of 125MLP instead of 500MLP 9. Discrepancies Noted container. —No x Discrepancies Noted NCDENR notified of Descrepancies' 10. Headspace present in VOC vials —No Headspace present in VOC vials >6mm nts: Inspected and Logged in by: TP Date: Fri-10/21/1100:00 `NCDENR must be notified when collection, hold iaggt/mecor preservation requirements are not met. MI_11.6