Loading...
HomeMy WebLinkAboutNCG140401_COMPLETE FILE - HISTORICAL_20100929STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /v DOC TYPE HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ a t7 ) -C) Q � a 9 YYYYMMDD Dumpor, Samir From: Edgerton, Thom Sent: Wednesday, September 29, 2010 11:12 AM To: Lowther, Brian Cc: Pickle, Ken; Hodge, Al; Dumpor, Samir; Vinson, Scott Subject: FW: SW General Permit NCG140401 Attachments: NCG140401_NOl.pdf Hello, The WaRO has no concern with the issuance of the COC. Permit compliance will lessen the impact. Please let me know if you need additional information. Thanks, Thom Thom Edgerton Environmental Engineer NCDENR - DWQ - Surface Water Protection Section Washington Regional Office (252)948-3955 Phone (252) 946-9215 Fax E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Edgerton, Thom Sent: Wednesday, September 29, 2010 8:45 AM To: Vinson, Scott Subject: FW: SW General Permit NCG140401 Hello, You sent Samir and I, a message trail from Ken Pickle on September 20th regarding a concrete plant in Wayne County, as a fyi. Is this part of the same project? Please let me know if I need to do anything with this. I am hoping these are the same project and that you have already completed this request. Thanks, Thom Thom Edgerton Environmental Engineer NCDENR - DWQ - Surface Water Protection Section Washington Regional Office (252)948-3955 Phone (252)946-9215 Fax E-mail correspondence to and from this address may be subject to the North Carolina Public Records law and may be disclosed to third parties. From: Lowther, Brian[mailto:brian.lowther@ncdenr.gov] Sent: Monday, September 27, 2010 1:47 PM To: Hodge, Al Cc: Thom Edgerton Subject: RE: SW General Permit NCG140401 Hey Al, I sent you this N01 last week but I wanted to check and see if you have a chance to look at it. Can you let me know how long the review will take and/or who it will be assigned to? Thanks Brian Brian C. Lowther Environmental Engineer NCDENR I DWQ I Stormwater Permitting Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 512 N. Salisbury St, Raleigh, NC 27604 Phone: (919)807-6368 Email: brian.lowther(u ncdenr.s,,ov Website: http://portal.ncdenr.ora/web/wq/wS/su E-mail correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties. From: Lowther, Brian Sent: Tuesday, September 21, 2010 5:08 PM To: Hodge, Al Subject: SW General Permit NCG140401 At, We've received an NOI from Southern Equipment Company, Inc. for their proposed facility in Goldsboro, Edgecombe County. The site currently doesn't discharge stormwater but could once the plant is operational. The receiving stream would be Big Ditch (C; NSW). The NOI is attached. The site will have no wastewater and might not have a stormwater discharge. They want the permit just in case a point sources occurs once they occupy the site. Ken and I meet with permittee and consultant this past Monday about the site. They wanted to make sure everything on the application was correct and expressed their need to get the permit as soon as possible. I told them I would call your office to explain their desired time frame. Can you do me a favor and let me know how long you think it will take to review this one? Thanks. Brian Brian C. Lowther Environmental Engineer NCDENR I DWQ I Stormwater Permitting Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 512 N. Salisbury St, Raleigh, NC 27604 Phone: (919) 807-6368 Email: brian.lowther(a)ncdenr.Bov Website: http://portal.nedenr.org/web/wq/ws/su 2 A"A NCDENR rmin.1.111 Wn NR . Prl.lo Division of Water Quality / Surface Water Protection National Pollutant Discharge Elimination System NCG140000 NCY USE ONLY m Rccelvcd Mondr Dav am orCnvcm §Ycar Amoun, 1UN3 —1 /at- � Assi io d to NOTICE OF INTENT National Pollutant Discharge Elimination System application for coverage under General Permit NCG140000: STORMWATER AND PROCESS WASTEWATER DISCHARGES associated with activities SIC (Standard Industrial Classification) Code - 3273 Ready Mixed Concrete For new plant sites that will discharge or recycle process wastewater (even If commingled with stormwater): This NOI Is also an APPLICATION FOR Authorization to Construct (ATC) wastewa treatment facilities. ATC requests must be submitted at least 90 days prior to construction'. For exlstina plant sites discharging or recycling process wastewater (even If commingled with stormwater): This NOI Is also an APPLICATION FOR Authorization to continue to operate wastewater treatment facilities In place. Construction, modification, or installation of any new treatment components at an existing site requires an ATC. Treatment facilities used to treat or recycle process wastewater (including stormwater BMP structures treating process wastewater flows commingled with stormwater) require an ATC prior to construction per 15A NCAC 2H .0138. The authorization to construct or continue to operate will be issued at the same time as the Certificate of Coverage (COC) for the NCG14 permit. Design of treatment facilities must comply with requirements of 15A NCAC 2H .0138 & .0139. Construction of wastewater treatment facilities (this Includes recycle systems) at new or existing plant sites requires submission of three (3) sets of plans and specifications signed and sealed by a Professional Engineer (P.E.) or qualified staff' along with this application. A copy of the design calculations should be Included. Please see questions 14 & 15. vi� For questions, please contact the DWO Regional Office for your area. (See page 5) (Please print or type) 1) Mailing address of owner/operator (address to which all Permit correspondence will be mailed): Name Street Address City Telephone No, 2) Location of facility producing discharge: Facility Name READY Mtmo CONCRETE — PORTABLC (PLANT Facility Contact R1nKY 11ol.L0r'IAN Street Address 0 N• AMES STREET - City Got o 5 Cio R o State tV C ZIP Code County WAYN E Telephone No. = I VA - 86 Fax: 919 'As per 15A NCAC 2H .0106 Page 1 of 5 °Unless treatment facilities are designed, constructed, and put Into operation by employees Internal to the company who are qualified to perform such work for their respective companies In accordance with General Statutes, 890.25 (7). plans and specifications must be signed and sealed by a P.E. SWU-229-071408 Last revised 7/14/08 NCG140000 N.O.I. 3) Physical location information: Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). TuST SouTh of TH E INTEI-SECTIoh7 OF GRAlv7_HAM STREET AND u _ TAn.tcs srvrF (A copy of a county map or USGS quad sheet vnth facility clearly located on the map Is a required part of this application.) e � u 4) Latitude N 35 Z3 31 Longitude W ql ,S9 10 r (deg, min, sec) 5) This NPDES Permit Application applies to which of the following: 2isNew or Proposed Facility Date operation is to begin ❑ Existing FWATAMLE _PLANT 6) Standard Industrial Classification: 10-15- 10 Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code: '3 2 r? 3 7) Provide a brief description of the types of industrial activities and products produced at this facility: (Include a site diagram showing the process areas present at this facility.) TH,S w14L ME A OfaN BATCH CONGR6.TE pLANT• Ttt ERG WIt.L. _Bra NO F9,0C.ES5 WASTEWATEtt C>ENERATEb AT THE S(T-E 8) Discharge points / Receiving waters: How many discharge points (ditches, pipes, channels, etc.) convey stormwater and/or wastewater from the property? NONE AT 1-1415 POINT UUT WILL gE EvA6vA_rF0 Ao NTINUALtY What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater and/or wastewater discharges end up in? B 1 G D 1 TG H If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). N A Receiving water classification (if known): C. N%w Note: Discharge of process wastewater to receiving waters classified as WS-II to WS-V or SA must be approved by the N.C. Dept. of Environmental Health. If DEH does not approve, coverage under NCG140000 cannot be granted. No new discharges of process wastewater are permitted In receiving waters classified as WS-I or freshwater ORIN. 9) Does this facility have any other NPDES permits? &-No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: 10) Does this facility have any Non -Discharge permits (ex: recycle permits)? No ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: 11) Does this facility employ any best management practices for stormwater control? ❑ No JKyes If yes, please briefly describe: G RAS SEp —MwK5 IN SECONDARY cot AREAS VVIASRE FSASIBLE OMMEVT ; AG(rRECATE S-r ADM, Page 2 of 5 S W U-229-071408 Last revised 7/14/2008 NCG140000 N.O.I. 12) Does this facility have a Stormwater Pollution Prevention Plan? 10"'No ❑ Yes If yes, when was it implemented? FAcIutTY WILL HAVE ONE Seli oPERA71o,/ 13) Are vehicle maintenance activities occurring or planned at this facility? R No ❑ Yes Wastewater Treatment Design Information 14) Are discharges occurring or planned from any of the following process wastewater generating activities? Vehicle and equipment cleaning ❑ Yes RINo Wetting of raw material stockpiles ❑ Yes Pf4o Mixing drum cleaning ❑ Yes 2<0 If yes to any of the above, please describe the type of process used to treat and/or recycle the process wastewater. For a sufficient application, you must provide design specifics (e.g., design volume, retention time, surface 1 area, etc.) and calculations to demonstrate compliance with permit effluent limits (pH - 6-9 SU, Total Suspended Solids (TSS) - 30 mg/I, and Settleable Solids (SS) - 5 mill.) [Use separate sheet(s)]. If all these discharges are recycled, please refer to Question 15. For plants that recycle and/or discharge process wastewater: When applying for this permit, you are also applying for an authorization to construct (new treatment facilities) or authorization to continue to operate (existing treatment facilities) as part of the N01. For new sites, you must submit three (3) sets of design plans and specifications with this application and provide supporting calculations that predict compliance of final discharge with permit limits. For ex/stlnq sites, applicants should submit three (3) sets of plans and specs for facilities as -built and provide as many design details as possible, or submit a detailed diagram of treatment systems in place that Includes Information such as tank volumes, dimensions, retention time, piping, settling basin details, etc. Please note: If new treatment systems are planned for an existing site, an ATC will be required prior to construction of those facilities. Plans/specs/calculations prepared by a P.E. and the request for an ATC may be submitted with this NOI, or separately at a later date. DINO may request the status of your plans for requesting an ATC upon Issuance of the COC. 15) Does the facility use or plan to use a recycle system? L7 No ❑ Yes If yes, what size storm event is the system designed to hold before overflowing? (for example, 10-yr, 24-hr) year, 24-hr rainfall event For a recycle system (regardless of when it overflows), please provide plans, calculations, and design specifics (e.g.. throughput assumptions/water balance, design volume, retention time, surface area, amount of freeboard in design storm event, etc.). [Use separate sheet(s)]. For a sufficient application, the information must demonstrate compliance of final discharge with permit _ effluent limits (pH - 6-9 SU, Total Suspended Solids (TSS) - 30 mg/I, and Settleable Solids (SS) - 5 ml/1), or must demonstrate that the recycle system has sufficient capacity to contain runoff from a 25-year, 24-hr rainfall event plus one foot of freeboard under design operating conditions. Page 3 of 5 SWU-229.071408 Last revised 7/14/200B NCG140000 N.O.I. 16) Air wastewater treatment facilities (including recycle systems) planned In the 100-year flood plain? R?No ❑ Yes If so, include information to demonstrate protection from flooding. (Minimum design requirements for treatment works include protection from the 100-year flood, per 15A NCAC 2H .0219.) 17) Hazardous Waste: a) Is is facility a Hazardous Waste Treatment, Storage, or Disposal Facility? Is ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of Wardous waste? No ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of hazardous waste? 2(No ❑ Yes d) If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport / disposal vendor: Vendor address: 18) Certification: North Carolina General Statute 143-215.6 B(I) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule Implementing this Article: or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article: or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental Management] Commission Implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Title: _A EAA of q-1'7- to (Date Signed) Notice of Intent must be accompanied by a check or money order for $100.00 made payable to: NCDENR Page 4 of 5 SWU-229-071408 Last revised 7/14/2008 NCG140000 N.0.1. Final Checklist This application will be returned as Incomplete unless all of the following Items have been Included: ❑ Check for $100 made payable to NCDENR. ❑ This completed application and all supporting documentation (including design details and calculations for treatment systems). ❑ If an Erosion & Sedimentation Control (E&SC) Plan is required from Division of Land Resources (DLR) or local designee: documentation verifying applicant has developed and submitted that Plan to the governing agency (required per 15A NCAC 02H .0138). ❑ For new sites (or sites that will Install new treatment facilities): Three (3) copies of plans and specifications for wastewater treatment facilities (including recycle systems), signed and sealed by a Professional Engineer or qualified staff meeting requirements of G.S. 89C-25 (7). ❑ For existing sites: three (3) copies of plans and specifications for wastewater treatment facilities (including recycle systems) as built, stamped and sealed by a Professional Engineer, or (only if plans not available) a detailed diagram of treatment systems in place that includes information such as tank volumes, dimensions, retention time, piping, settling basin details, etc. ❑ A site map showing, at a minimum, (existing or proposed): (a) outline of drainage areas, (b) stormwater/wastewater treatment structures, (0) location of stormwater/wastewater outfalls (corresponding to which drainage areas), (d) runoff conveyance structures, (e) areas where materials are stored, (f) impervious areas, and (g) site property lines. ❑ A county map or USGS quad sheet with location of facility clearly marked. Mail the entire package to: Stormwater Permitting Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Note The submission of this document does not guarantee the Issuance of an NPDES permit. For questions, please contact the DWO Regional Office for your area. DWO Regional Office Contact Information: Asheville Office ...... (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ...(252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office .........(919) 807-6300 Page 5 of 5 SWU-229.071408 Last revised 7/14/2008 ATTACHMENT A DRAWINGS MID -ATLANTIC ASS O C [ ATE S. [ N C. Engirirering @ £rmironnirnml Snlurionr Aid n'� N REFERENCES: 1. NORTHEAST GOLDSBORO, NC AND NORTHWEST GOLDSBORO, NC DIGITAL RASTER GRAPHIC FILES, US GEOLOGICAL SURVEY. SCANNED FROM 1:24,000SCALE MAPS OF THE SAME NAMES, PUBLISHED 1998, USGS. 2. INSET MAP DIGITAL DATA FROM 2002 NATIONAL TRANSPORTATION ATLAS, BUREAU OF TRANSPORTATION STATISTICS, WASHINGTON, D.C. TT TOPOGRAPHIC SITE MAP MID -A 1 1.ANTII READY MIXED CONCRETE 708 NORTH JAMES STREET Eng ureerure & Pn si rourn enm7 snlu.re°'` GOLDSBORO, NORTH CAROLINA SCALE: 1:12,000 1,000 DRAW BY: DRAFF CHECK: ENG. CHECK: 11 MM Feet 2,000 DATE: SEPTEMBER 2( JOB NO: 00OR1255.27 01G-R1255,27-1 V0: 1.1 MID -ATLANTIC AS SOCtATES, INC. Engineering & Environmental Sohrrions 409 Rogers I7ew Cnurr I RaI,igI, IN,,, Carofma 127rilir 506-486J5631919-250-99181919-? 0-9950 Focsunile W1111 /rL1iNI1110e. i Jrll September 20, 2008 Mr. Ken Pickle North Carolina Department of Environment and Natural Resources Division of Water Quality Stormwater and General Permits Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Subject: SUBMITTAL OF NOTICE OF INTENT READY MIXED CONCRETE COMPANY 708 NORTH JAMES STREET GOLDSBORO, NORTH CAROLINA MID -ATLANTIC PROJECT NO.000R1255.27 Dear Mr. Pickle: Mid -Atlantic Associates, Inc. (Mid -Atlantic), on behalf of Ready Mixed Concrete Company (RMCC), appreciates the opportunity to submit this Notice of Intent (NOI) for the portable ready mixed concrete facility proposed for 708 North James Street in Goldsboro, North Carolina. This plant will be a portable plant associated with a specific job recently awarded in the county. The plant anticipates starting operation on or about October 15, 2010 and would appreciate a expedited review of this NOI. We apologize for this request but RMCC have been working diligently to get the information necessary for this submittal since being awarded the job. As shown on the attached drawing and based on a site visit by RMCC personnel, there are currently no point source discharges off site. The plant will be inspected during operation to see if this situation changes. In addition, there will be no process wastewaters generated at this site. Truck washing and mixing drum clean out will occur at RMCC's nearby permanent plant location. Due to the timing of this project, aggregate stockpiles will not need to be irrigated. Submittal of Notice of Intent Ready Mixed Concrete Company. 708 North James Street Goldsboro, North Carolina September 20, 2008 Page 2 We appreciate the opportunity to submit this information. If you have any questions or need additional information, please do not hesitate to call us at 250-9918. Sincerely, MID- LANTIC ASSOCIATES, INC. Darin M. McClure, PE Principal Engineer Attachment: Notice of Intent Attachment A —Drawings cc: Mr. Dexter Tart, Ready Mixed Concrete Company 1255.2719-16-10 NOI Cover Letter/DMM/bro MID -ATLANTIC ASS O C I ATE S. INC. Eng Lree ring & Errrirorvo eu ral So huianr NCDENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Governor Director September 29, 2010 Mr. Ricky Holloman Southern Equipment Company, Inc. 3610 Bush Street Raleigh, NC 27609 Dee Freeman Secretary ":;; Ir ' 17. rt7 7 r s OCT — 5 mo Subject: General Permit No. NCG140000 Southern Equipment Company, Inc. Ready Mixed Concrete — Portable Plant COC NCG140401 Wayne County Dear Mr. Holleman: In accordance with your application for a discharge permit received on September 20, 2010, we are forwarding herewith the subject certificate of coverage to discharge under the subject state —NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143- 215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please take notice that this certificate of coverage is not transferable except after notice to the Division of Water Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or anv other federal or local governmental permit that may be required. If you have any questions conceming this permit, please contact Brian Lowther at telephone number (919) 807-6368 Sincerely, for Colleen H. Sullins cc: Washington Regional Office Central Files Stormwater Permitting Unit Files Wetlands and Stormwate: °ranch One 1617 Mail Service Center, Raleigh. North Carolina 27699-1617 NorthCat of i na Location: 512 N. Salisbury St. Rateyh. North Carolina 27604 q// Phone. 919 807-63001 FAX. 919wuw.£07-64941 Customer Service: 1.877-623-6748 ��ll�lllll![� Internet: ncwa:erqualiry.org [(�� ;/ STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY II STORMWATER DISCHARGES In compliance with the provision of North Carolina, General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Southern Equipment Company, Inc. is hereby authorized to discharge stormwater from a facility located Ready Mixed Concrete — Portable 708 N. James Street Goldboro. NC Wayne County to receiving waters designated as Big Ditch, a class C; NSW water accordance with the effluent limitations, monitoring requirements, in Parts 1, II, 111, IV, V, and VI of General Permit No. NCG140000 the Neuse River Basin, in d other conditions set forth attached. This certificate of coverage shall become effective September 29, 201.0 This Certificate of Coverage shall remain in effect for the duration Signed this day September 29, 2010. ,for Coleen H. Sullins, Director Division of Water Quality By the Authority of the Environmental General Permit. Commission LOCATION MAP: `zf1" S MLj �F % �.� � •II if ,+I� � rurr �la _ si!\ ����M1.e�ry` �� � � ` `-1 � I- } I . i �. I� E� ( '' N S /•l' .�%V � y � t, a !: ,. d� f lid �_-. ) ` sr ♦ -- ._ — � t.�ia %�e-- h:6alm�M, N� .: ::�. Ready Mised Concrete -Portable Plant � t NCG140401 Southern Equipment Company, Inc. Ready Mised Concrete -Portable Plant Lab hide: 350 23' 31" N Longibide: 770 59' 40" W } ..' County: Wayne Recewng Stream: Big Dtdi Stream Cass: C; NSW Mn n Scale 1,24,000 Sub-badn: 03-04-12 (Neuse River Bacin) Facility Location