July 29, 2008
Mr. Rick Proctor
PLT Concrete Services, Inc.
4541 Dozier Rd
Rocky Mount, NC 27801
SUBJECT: Compliance Evaluation Inspection
PLT Concrete Inc., Rocky Mount Plant
Permit Number— NCG140320
County - Nash
Dear Mr, Proctor:
On June 5, 2008, Autumn Hoban, of the Division of Water Quality (DWQ), Raleigh Regional Office, performed a
stormwater compliance evaluation inspection of PLT Concrete, Inc. in Zebulon. The assistance and cooperation
of Mr. Dexter Clark and the other site personnel was helpful and greatly appreciated. Inspection findings are
listed below.
Industry, and Site Description;
PLT Concrete Plant mixes concrete on -site for delivery to construction sites, road projects, and residential
customers. Stormwater runoff and process wastewater generated at such facilities is regulated by General
Permit NCG140000. DWQ has therefore issued certificate of coverage, NCG140320, which became effective
on April 1, 2004 and expires on July 31, 2009.
Stormwater and other wash waters on -site are directed to a wet detention pond. The facility has one stormwater
outfall from the detention pond to a level spreader, to a sod filter strip and then sheet flows off the property.
There was no discharge the day of the inspection. This facility can use up to 20% fly ash in their concrete
mixture.
Inspectlon,Sumrtiary- 3
The facility keeps good records and was in compliance with permit requirements. The Stormwater Pollution
Prevention Plan (SWP3) was reviewed and implementation of BMP's evident.
Secondary Cbntaiririienf;
It is recommended that the facility insure the secondary containment area is adequate to contain the volumes of
product stored on -site in the event of a tank failure. Please use caution and do not store more product than the
secondary containment design allows. This facility was in compliance with secondary containment.
3400 Barrett Drive
Raleigh, North Carolina 27609
Phone: 919-791-4200 Fax: 919-788-7159
NorthCarolina
Natura!l�
Michael F. Easley, Governor
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
— --- .. Coleen H. Sullins, Director
Division of Water Quality
Qualitative Mon'itonng �';
Qualitative monitoring was completed as required and records were reviewed.
Analytical Monitonng;
The facility conducted the required analytical monitoring. The latest sample at the discharge outfall was taken
on 2/18/2008. The results showed Total Suspended Solids was 50 ni and Settleable Solids of 0.1. The day
of the inspection, sample results from the detention pond showed a Total Suspended Solids of 7 mg/L.
The facility has one outfall. The permittee was not discharging the day of the inspection.
Samples of wastewater were taken at the detention pond for analysis. The sample was taken to identify the
constituents of the wastewater on -site. The results indicate Total Dissolved Solids was 305 mg/L, with the
following levels of metals detected: Aluminum 1100 ug/L, Titanium 35 ug/L, Iron 960 ug/L, and Lithium 47 ug/L.
The presence of Titanium has not been seen at other cement plants in the Raleigh Region. The Aluminum and
Iron levels are consistent with the sample results from other cement plants in the area. The sample results
report is attached.
It is our goal to insure the quality of the surface waters of this State.
If you or your staff has any questions, do not hesitate to contact Autumn Hoban at 919-791-4200.
Sincerely,
Autumn Hoban
Enclosures
cc: Central files
RRO/DWQ Stormwater Compliance Files
Stormwater Permitting Unit
3400 Barrett Drive
Raleigh, North Carolina 27609
Phone: 919-791-4200 Fax: 919-788-7159
NorthCarolina
;Vatura!!y
Permit:
NCG140320
SOC:
County:
Nash
Region:
Raleigh
Compliance Inspection Report
Effective: 08/01/04 Expiration: 07/31/09 Owner: PLT Concrete Services Incorporated
Effective: Expiration: Facility: PLT Concrete Services Inc - Rocky Mount
4541 Dozier Rd
Rocky Mount NC 27801
Contact Person: Rick Proctor Title: Phone: 252-293-0500
Directions to Facility:
System Classifications:
Primary ORC: Certification: Phone:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 06/05/2008 ,Entry Time: 08:00 AM Exit Time: 08:30 AM
Primary Inspector: Autumn Hoban Phone: `1/ % /1
Secondary Inspector(s): qek����_.
Reason for Inspection: Routine �° Inspection Type: Compliance Evaluation
Permit Inspection Type: Ready Mix Concrete Stormwater/Wastewater Discharge
CDC
Facility Status: ■ Compliant ❑ Not Compliant
Question Areas:
E Storm Water
(See attachment summary)
Page: 1
Permit: NCG140320 Owner- Facility: PLT Concrete Services Incorporated
Inspection Date: 06/05/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
Plant was designed with good stormwater controls. The site uses well water and has no recycle system. The forebay and
wet detention pond on -site are in need of maintenance. The detention pond had stagnant water, a lot of plant growth,
sediment, and an algal bloom.
Attention to routine maintainance is required to maintain the wet detention pond controls for performance as designed.
No water quality issues were observed the day of the inspection. No discharge.
The detention pond was sampled the day of the inspection with the following noted, TSS 7.5 mg/L, Aluminum 1100 ug/L,
Titanium 35 ug/L, Iron 960 ug/L, Lithium 47 ug/L. The presence of Titanium has not been seen at other cement plants in
the Raleigh Region, the Aluminum and Iron levels are consistent with the sample results from other cement plants in the
Raleigh Region. The sample results report is attached.
Page:2
Permit: NCG140320 Owner- Facility: PLT Concrete Services Incorporated
Inspection Date: 06/05/2008 Inspection Type: Compliance Evaluation
Reason for Visit: Routine
Stormwater Pollution Prevention Plan
Yes
No
NA
NE
Does the site have a Stormwater Pollution Prevention Plan?
■
❑
❑
❑
# Does the Plan include a General Location (USGS) map?
■
❑
❑
❑
# Does the Plan include a "Narrative Description of Practices"?
■
Cl
❑
❑
# Does the Plan include a detailed site map including outfall locations and drainage areas?
■
❑
❑
❑
# Does the Plan include a list of significant spills occurring during the past 3 years?
■
❑
❑
❑
# Has the facility evaluated feasible alternatives to current practices?
■
❑
❑
❑
# Does the facility provide all necessary secondary containment?
■
❑
❑
❑
# Does the Plan include a BMP summary?
■
❑
❑
❑
# Does the Plan include a Spill Prevention and Response Plan (SPRP)?
■
❑
❑
Cl
# Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?
■
❑
❑
❑
# Does the facility provide and document Employee Training?
■
❑
❑
❑
# Does the Plan include a list of Responsible Party(s)?
■
❑
❑
❑
# Is the Plan reviewed and updated annually?
m
❑
❑
❑
# Does the Plan include a Stormwater Facility Inspection Program?
■
❑
❑
❑
Has the Stormwater Pollution Prevention Plan been implemented?
■
❑
❑
❑
Comment:
Qualitative Monitoring
Yes
No
NA
NE
Has the facility conducted its Qualitative Monitoring semi-annually?
■
❑
❑
❑
Comment: Qualitative monitoring completed as required by the permit.
Analytical Monitoring
Yes
No
NA
NE
Has the facility conducted its Analytical monitoring?
■
❑
❑
❑
# Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas?
❑
❑
■
❑
Comment: Anayltical Monitoring completed as required by the permit.
Last sample was taken 2/18/2008. Results were as follows: Total Suspended Solids 50
mg/L and Setteable Solids 0.1.
Permit and Outfalls
Yes
No
NA
NE
# Is a copy of the Permit and the Certificate of Coverage available at the site?
■
❑
❑
❑
# Were all outfalls observed during the inspection?
00011
# If the facility has representative outfall status, is it properly documented by the Division?
■
❑
Cl
❑
# Has the facility evaluated all illicit (non stormwater) discharges?
■
❑
❑
❑
Page: 3
Permit: NCG140320 Owner- Facility: PLT Concrete Services Incorporated
Inspection Date: 06/05/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Comment: The forebay and stormwater pond are overgrown with cattails. The
stormwater pond had an algal bloom occurring the day of the site visit. The pond and
forebay need routine maintenance. The outfall was dry and no overflow to grass filter
strip observed. No creek was seen, sheetflows to neighboring commericial facility
behind site and eventually into a stormdrain by the road.
Page:4
SAMPLE RESULTS REPORT
Report Date :7/25/2008
Report Time : 8:03:51AM
Sample Delivery Group (SDG): 08060614
Thank you for your request. The following sample results are from our system as currently reported on the above date and time.
Sample Type Sample ID Test Code
Analyte Name
Result
Units
,MDL
Method
NCG 14032 AB31023
PHOSTOTP
Phosphorus_total as P in liquid
0.06
mg/L as
0.02
Lac to- 115-01-I EF
RESSUS_W
Residue_Suspended in liquid
7.5
mg/L
6.2
APHA2540D-20th
T AL_LIQ
AI by ICP
1100
ug/L
50
EPA 200.7
AS_LIQ
As by ICPMS
5.0
ug/L
5.0
EPA 200.8
ZN_LIQ
Zn by ICPMS
10
ug/L
10
EPA 200.8
PB_LIQ
Pb by ICPMS
10
ug/L
10
EPA 200.8
NI_LIQ
Ni by ICPMS
10
ug/L
10
EPA 200.8
CU_LIQ
Cu by ICPMS
2.0
ug/L
2.0
EPA 200.8
TEMP_REC
Sample temperature at receipt by lab
2.2
°C
CD_LIQ
Cd by ICPMS
1.0
ug/L
Lo
EPA 200.8
HG_LIQ
Hg 245.1
0.20
ug/L
0.2
EPA 245.1
TKNN_LIQ
Total Kjeldahl N as N in liquid
0.76
mg/L as N
0.2
Lachat107-06-2-H
NO2&NO3_
NO2aNO3 as N in liquid
0.02
mg/L as
0,02
Lac 10-107-04-1-c
NH3N_LIQ
NH3 as N in liquid
0.02
mg/L as N
0.02
LacIO-107-06-1-J
-is TDS_LIQ
Total Dissolved Solids in liquid
305
mg/L
12
APHA2540C-18TH
$WET_ICC
Sulfate
39
mg/L
20
EPA 300,0
$WET ICC
Chloride
3.4
mg/L
1.0
EPA 300.0
SWET_ICC
Fluoride
0,4
mg/L
0.4
EPA 300.0
CHROMIUM
Cr by ICPMS
10
ug/L
10
EPA 200.8
K_LIQ
K by ICP
62
mg/L
0.10
EPA 2003
MN_ICP_L
Mn by ICP
13
ug/L
10
EPA 200.7
CO_ICP_L
Cobalt by ICP
50
ug/L
50
EPA 200.7
• TI_LIQ
Ti (Titanium) by ICP
35
ug/L
10
EPA 200.7
THALLIUM
Thallium (Ti) ICPMS
10
ug/L
10
EPA 200.8
SN_LIQ
So by ICPMS
10
ug/L
10
EPA 200.8
SB_LIQ
Sb by ICPMS
10
ug/L
10
EPA 200.8
MO_LIQ
Min by ICPMS
10
ug/L
10
EPA 200.8
FE_LIQ
Fe by ICP
960
ug/L
50
EPA 2003
-r LI_LIQ
Li ICP
47
ug/L
25
EPA 200.7
NA_LIQ
Na by ICP
17
mg/L
0.10
EPA 200.7
CA_LIQ
Ca by ICP
31
mg/L
0.10
EPA 200.7
V_LIQ
V by ICP
25
ug/L
25
EPA 200,7
CO LIQ
Cobalt by ICPMS
PENDING
ug/L
EPA 200A
BE_LIQ
Be by ICP
5.0
ugfL
5,0
EPA 200.7
BA_LIQ
Ba by ICP
20
ug/L
10
EPA 200.7
AG_LIQ
Ag by ICPMS
5.0
ug/L
5.0
EPA 200,8
SE_LIQ
Se by ICPMS
5.0
ug/L
5.0
EPA 200.8
MG_LIQ
Mg by ICP
2.4
mg/L
0.10
EPA 200.7
Page 1 of 1
rvuuian r. eusiey, uuvemul
William G. Ross Jr., Secretary
North Carolina Department of Environment and Natural Resources
February 28, 2003
Mr. Rick Proctor, General Manager
PLT Concrete Services, Inc.
3214 Tumage Rd
Wilson, NC 27893
Subject: Notice of Violation
Stormwater Compliance Inspection
PLT Concrete Services, Inc.
NPDES Stormwater Permit NCG 140320
Rocky Mount, NC
Nash County
Dear Mr. Proctor:
Alan W. Klimek, P.E. Director
Division of Water Quality
a CCp�1
On February 24, 2003 Mr. Myrl Nisely of the Raleigh Regional Office of the Division of Water Quality made a
compliance inspection at the Rocky Mount facility. A copy of the inspection is attached. The help provided by Mr.
Wayne Maxwell was appreciated. The results are as follows:
1. The Stormwater Pollution Prevention Plan manual (SP3) is to contain the following sections for which data was
missing or incomplete:
a) a USGS map with latitude and longitude shown (a map was in the front pocket, contrary to what was said in the
telephone conversation with Mr. Nisely. Please add the latitude and longitude) Part II(A)(1)(a)
b) a Narrative Description of Practices per Part II(A)(1)(b)
c) a site map showing rainwater flow patterns, % impervious surface and so forth per Part II(A)(1)(c)
d) a statement certifying there have been no spills in the last three years (or since the plant opened), per Part
II(A)(1)(d)
e) Feasibility of Changing Practices (a short statement concerning design of the site with stormwater in mind) per
Part II(A)(2)(a) See also g) below.
f) Records of Draining Containment Areas and Observations made, Part II(A)(2)(b)
g) A summary of BMPs used at this plant, Part II(A)(2)(c)
h) A narrative Spill Prevention and Response Plan, in addition to the reporting templates in the manual, Part II(A)(3)
i) A Preventative Maintenance and Housekeeping Plan, Part II(A)(4)
j) Record of Employee Training, signed by each attendee with Stormwater topic(s) covered, Part II(A)(5)
k) A page showing Responsible Parties and chain of command, with telephone numbers, Part II(A)(6)
1) Please revise the statement by the Engineering firm who crafted the manual that the Plan will be reviewed and
updated ANNUALLY, not "at least every three years". Part II(A)(7)
m) Part II(A)(9), Implementation will be satisfied in the future by evidence of data in each section of the manual
n) At the time of your first sampling round, be sure to include Qualitative Monitoring, Part II(F). Please also enter
into the manual a narrative of how and where annual sampling will be done.
The above omissions warrant NOV status for this inspection. The manual is to be the repository for activities in each
area and a resource for employees regarding stormwater protection.
u'.'"T
NCDE<tiR
N. C. Division of Water Quality 1628 Mail Service Center Raleigh, NC 27699-1628 (919) 571-4700 Customer Service
Raleigh Regional Office 1 800 623-7748
ru wi iu etu aei vices, uic.
rage z
The back of the manual held many engineering design charts, maps and other data related to the design of the plant
but not a part of the permit. You may wish to move these to another storage binder as the manual fills with the above
information over time.
2. It was noted that inspections of the facility were documented monthly, going beyond the permit requirement of semi-
annual inspections. This is commendable, especially for the first couple of years as experience is gained in how the
stormwater system performs.
3. A tour of the site showed that concrete disposal, if any, is done by either pouring blocks or by increasing the paved
area. Drum washouts are done is a specially designed area in which the washout water is reused for other drum
washouts, but is not used in making more concrete. In a heavy rain, this water may overflow that recycle system into
another cell normally holding only rainwater. In an extremely heavy rain, that cell would slowly discharge to the
perimeter swale and make its way to the stormwater pond and subsequent system.
4. Vehicle washing is done near the entrance gate. These solids accumulate at the head of the eastern swale that runs the
length of the plant. These are periodically scooped up for disposal.
5. Solids accumulated in the washout areas are held in a containment area near the drum washout system, and are
periodically hauled away for use as fill.
6. Secondary containment structures for fuels and for admixture chemicals were clean and the drain handles were
locked. Draining practice is to leave about %:" of water to avoid draining any oily layer. An observation record is to
be used and signed each time a containment is drained. All held only clean rainwater at this time.
7. Housekeeping was excellent, and the concrete surfaces in the plant were clean and well kept.
8. Only minor runoff into a crushed stone surface is expected from aggregate sprays in the center of the site. This will
be insignificant.
9. Vehicle Maintenance reportedly uses less than 55 gallons of new motor oil per month, so is exempt from Part II(B)(2)
Thank you for your attention to correcting the program omissions identified. If you have comments or questions, please
contact Mr. Myrl Nisely at 919 571-4700.
Sincerely,
Kenneth Schuster, P.E.
Regional Supervisor
cc: NPDES Compliance Unit
Nash Co. Health Dept.
Central Files
Readymix Concrete Stormwater Inspection Checklist
Type of Visit -Compliance Inspection/Program Audit Tech Assistance or Recon
Location: P.LT Cone' " ete Servlces IncRocky'MounNC
} r
Facility Number NCG14W20Datc2/24/03 Time lril: fo,PFM Time Out 2 S-
People Interviewed, and Titles: Wayne Max ell,l n0Manager Rick UPcroctor,';Geii �Mg
SPPP Documentation (Site Plan Part II (A)(1)
1. Copy of Certificate of Coverage ®Yes pNo Copy of Permit ®Yes ®No Requested but not required
2. General Location (USGS) Map shows plant'Yes 'E]No, lines of discharge Part II(A)(1)(a)
to water of State 71,Yus FmA'Nu, Stream labeled'Yes piJo, Latitude and longitude pYes nNo
Comments: Is atno�ri��d schargeisite"r,sojr doaIines
3. Narrative Description of Practices es E)�,
4. Site map MYes'_No Shows flows & areas
% impervious surface 'Yes cc"No, buildings
disposal areas ®Yes pNo, drainage structures'
D'Yes pNo, list of potential pollutants MYes't
5.
EM Part II(A)(1)(b)
led with arrows and Part II(A)(1)(c)
rallo, process areas pYes'pNo,
s pNo, existing BMPs such as secondary containment
List of significant spills in last 3 years or certif. if none't]Yes ®TIo Nofieirice tart
RRO called?
A
7. Feasibility of Changing Practices g Yes NNo 'Eofe pinf was%de`sig�nec
8. Secondary Containment ®Yes MNol= Schedule needed? pYess I
Records of Draining Containment, Observations Made _pYes E
9. BMP Summary [Yes'
No
10. SPRP Plan pYes 'oNo, Responsible personnel still employed here?
11. PM and Housekeepine Plan ®Yes ®No M Record of Inspectio
12. Employee training pYes MNo — for -everybody 'Byes 'No "�
13. Responsible parties, chain of command page m Yes ®No
14. Plan updated/reviewed annually ®Yes ®No To be done`annually,
^w?'
15. Stormwater Facility Inspection Program Ayes pNo B,ein�g;3 §
donemc
16. This Plan Has Been Implemented (documents in manual,
employees show awareness ° Yes MNo Comments:: ocdments�rf"ieedM
Sampling and Analytical Data
All Stormwater and Process Water is Recycled (IIC(3)1 pYes ®No
Rain Gauge on site (not required) pYes Fi N
Part II(A)(1)(d)
Part II(A)(1)(e)
Part II(A)(2)(a)
Part II(A)(2)(b)
Part II(A)(2)(c)
es "MNo '" t Part II(A)(3)
ac Yes No
Part II(A)(4)
Part II(A)(5) .
Part II(A)(6)
IE-1ee
Part II(A)(7)
ly
Part II(A)(8)
Part II(A)(9)
Part II(C)
If 40 yr storm and overflows, sample. If>16 yr storm, sampling not required. How do they know if 10 yr storm or not?
Record of an overflow pYes ®No Details
If not all recycled, what is allowed to discharge? Vehicle Cleaning (IIC2) E] Recycle overflow (IIC3
above) Fq Wetting of Aggregate (IIC4)E] Mixing drum cleanout (IIC5) E]
Compliant?
Total precip ®Yes pNo, Storm duration g Yes ONO, Total flow Est. RjYes ®No,Field pH 'Yes ONO,
pY Chain of custody es pNo
Qualitative Monitoring performed semiannually MYes j§No Wet g DryI?h Part II(F)
Stormwater not ayes
with process wastewater — general runoff PartlI(C)(1)
Analytical data 4[T es 'No, Chain of Custody pYes ONO, Qualitative Monitoring performed
semiannually (Section F) pYes pNo,
Wet Q Dry d
If using cutoff policy, how many sample rounds
Cutoff Concentrations met ®Yes E&o MEver have a Bypass? pYes bNo (III (C)(4)al &2)
Notification given? 'py'es p'Vo
Outdoor Inspection
I located all discharge points eBi Yes DNo No. of areas served
Sample points appropriate
Housekeeping: Trash pYes pNo Dust p'%es pNo CI`ean we 1Fkeut s Ye
Take -pEpYes'ONO Value(s)
Take photos pYes ®No
Containment Area satisfactory Eyes pNo, Loose drums EYes''oNo, Locked drain ®Yes pNo
Concrete disposal pile comments No"neJse"left ouergfor blocks o" ""r"pavin
Recommendations:
Requirements:
Letter is to go to:
Name Rick1Progt r-11 n' eral;Iylan ger
Title
Address
United Stales Environmental Agency
Form Approved.
EPA Washington, D C. 20460
OMB No. 2040-0057
- Water Compliance -Inspection Report
Approval expires&31-98
Section A: National Data System Coding (i.e., PCS)
Transaction Code NPDES yr/mo/day Inspection Type Inspector Fee Type
1 t„I 2 'cl 3I N00140320 I11 12I 03/02/24 117 18f�.1 191S1 201�1
[Li
U Li LJ LJ
Remarks
2111111111111111111111111111111111,1111111111111161
Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 OA. ---------------------Reserved-----------------
67 1 1 69 70 1 3 1 71 Lj 72 1„J I 1 t I 73 I I' 74 75I 11 1 I I I 180
LJ l
Section B: Facility Data
Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include
Entry Time/Date
Permit Effective Date
POTW name and NPDES permit Number)
01:20 PM 03/02/24
02/05/17
PLT Concrete Services Inc - Rocky Mount
Exit Time/Date
Permit Expiration Date
-
Dozier Road
Rocky Mount NC 27801
02:55 PM 03/02/24
04/07/31
Name(s) of Onsite Representative(s)/Titles(s)/Phone and Fax Numbers)
Other Facility Data
Rick Proctor//252-451-6807/
Wayne Maxwell//252-451-9450/
Name, Address of Responsible Official/Title/Phone and Fax Number
Contacted
Ricky Proctor,3214 Turnage Rd Wilson NC 27893//252-293-0500/ No
Section C: Areas Evaluated During Inspection (Check only those areas evaluated)
Permit Records/Reports Facility Site Review Storm water
Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary)
Site engineered for SW. Non-compliance centers around documents needed in the Stormwater Manual at the
site.
Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date
RRO WQ//919-571-4700/919-571-9718
MyYl Ni sely .\'I1N,I1.\'��ljnV/�/P�
4
Sig of Management O A Reviewer Agency/Office/Phone and Fax Numbers Date
��. c�4&All 2- Z 703
EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete.
p f F W ATF
I! �Q Michael F. Easley
j, \0 OG Governor
VJ. r William G. Ross Jr., Secretary
>_ y Department of Environment and Natural Resources
O T Gregory J. Thorpe, Ph.D, Acting Director
Division of Water Quality
May 17, 2002
Mr. Rick Proctor —
PLT Concrete Services, Inc.
3214 Turnage Road
Wilson, NC27893 11 MA� 2 AT,l�
Subject: General Permit No. NCG140000
PLT Concrete Services, Inc.
COC NCG140320 —
Nash County
Dear Mr. Proctor:
In accordance with your application for discharge permit received on April 10, 2002, we are forwarding herewith
the subject certificate of coverage to discharge under the subject state - NPDES general permit. This permit is issued
pursuant to the requirements of North Carolina General Statute 143-215 .1 and the Memorandum of Agreement between
North Carolina and the US Environmental Protection agency dated December 6, 1983.
The stormwater permit you are receiving, NCG140000, does not permit wasting concrete, dumping excess
concrete, directly into storm sewer outfalls or into waters of the state. Any facility which either, dumps excess concrete or
washes excess concrete into storm sewers or waters of the state will be operating in direct violation to both the terms of
this permit and the North Carolina General Statutes.Such,a discharge shall be considered ad illegal discharge and may
subject the owner to enforcement actions in accordance with North Carolina General Statutes 143-215.6A
If any parts, measurement frequencies or sampling requirements contained in -this permit are unacceptable to
you, you have the right to request an individual permit by submitting an individual permit application. Unless such
demand is made, this certificate of coverage shall be final and binding.
Please take notice that this certificate of coverage is not transferable except after notice to the Division of Water
Quality. The Division of Water Quality may require modification or revocation and reissuance of the certificate of
coverage.
This permit does not affect the legal requirements to obtain other permits which may be required by the Division
of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act or any other
Federal or Local governmental permit that may be required.
If you have any questions concerning this permit, please contact Mr. Mack Wiggins at telephone number 919/733-
5083 ext. 542.
cc: Raleigh -Regional Office
Central Files
Stormwater and General Permits Unit Files
Sincerely,
-•�Stsiitu 8Y
Gregory J. Thorpe, Ph.D
=M
,NCDENR
Customer Service
1 800 623-7748
Division of Water Quality 1617 Mail Service Center Raleigh, NC 27699-1617 (919) 733-7015
STATE OF NORTH CAROLINA
DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES
DIVISION OF WATER QUALITY
GENERAL PERMIT NO. NCG140000
CERTIFICATE OF COVERAGE No. NCG140320
STORMWATER AND PROCESS WASTEWATER DISCHARGES
NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM
In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and
regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the
Federal Water Pollution Control Act, as amended,
PLT Concrete Services, Inc.
Is hereby authorized to discharge stormwater and washwater from drum wash basin, from a facility located at
PLT Concrete Services, Inc.
Dozier Road
west Rocky Mount
Nash County
to receiving waters designated as Stony Creek, Class C-NSW waters in the Tar -Pamlico River Basin
in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III,
IV, V, and VI of General Permit No. NCG140000 as attached.
This certificate of coverage shall become effective May 17, 2002.
This Certificate of Coverage shall remain in effect for the duration of the General Permit.
Signed this day May 17, 2002.
!tnl3lN��A/1lS(,�t.ty av
Gregory-J. Thorpe, Ph.D, Acting Director
Division of Water Quality
By Authority of the Environmental Management Commission
77-
Qt
ng
-W. Low
4�lyCou'rs P v;ICoAQ,,,.
'2
7`2-62 5�
7A
IVI
10h.-
Ay 1, WPI
�WM
p% 'Pig
70
wkm 25
;e
jp
."Kiv
-1b 3, "'MOM-
L
1,41 C
gr
3S.", W-A!
Ja
We - � IF; s � X�K.;
A'
Pip
�r,cek
Kl-
r
4
11'"scharg'b"i!� 'efV -
va
W2V*'
Pj
77-7�f--- Park I
C1.1-
1MV
Tr u Par Ch k1k,
ip
r.I
6nbur It.
M"T It
NX
vi
4 -�AR�
11,; WEN
'Halifax I Mj
A
A� A ........
�'y�a` '4rt.^ 2 ��,�5 Zap i r �i� ��—�
NIP,
Al
a.
-MIR
N.
N
7
9*W
Copyright (C) 1997, Maptech, Inc