Loading...
HomeMy WebLinkAboutNCG140128_COMPLETE FILE - HISTORICAL_20030429STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. w u& DOC TYPE, 2HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ of U.3 (-Oy) YYYYMMDD r ; 4 0�0� W A TF9oG >_ULM O � Mr. Larry" Spence Ready Mix Concrete, Inc 3610 Bush Street Raleigh, NC 27609 Dear Mr. Spence: Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality 129 2003 Subject: Stormwater Compliance Inspection Ready Mix Concrete Butner Plant NPDES Stormwater Permit NCG 140128 Butner, NC Granville County On April 21, 2003 Myrl Nisely of the Raleigh Regional Office of Division of Water Quality made a compliance inspection at the Butner facility. The help Mr. Steven Ray provided was appreciated. The results were as follows (also see attached checklist): 1. Stormwater drains into two swales along each side of this site to separate discharge points, and eventually goes to Falls Lake. Near the end of each swale is a crushed rock checkdam that helps settle any solids. 2. Vehicle wash water flows onto a pervious crushed rock area. Volume is only occasionally enough to get to the swale. 3. Unused concrete is poured into blocks, or if a very small amount, is washed out to the drum wash pit. This pit is at the front of the plant. Water is retained unless a heavy rain occurs, when it makes its way to the head of one of the swales. Solids are removed from the pit two or three times per year. This material is taken offsite by a recycler. 4. Admixture chemicals and fuel were inside containment structures. 5. Documentation in the SP3 manual was complete and well organized. Three years' of sampling data showed compliance. This facility complies with the stormwater permit. Sincerely, 1Y et , )L Myrl A. Nisely Environmental Specialist xc: Orange County Health Dept. Central Files Raleigh Regional Office 1628 Mail Service Center phone (919) 571-4700 Customer Service NCUENR Water Quality Section Raleigh, NC 27699-1628 facsimile (919) 571-4718 1-877-623-6748 0 Readymix Concrete Stormwater Inspection Checklist Type of Visit MCompliance Inspection/Program Audit aQ,; Tech Assistance or Recon Location: Southern Equipm' ent`Readymi� #13 People Interviewed; SPPP Documentation (Site Plan Part II (A)(1) 1. Copy of Certificate of Coverage ®Yes pNo Copy of Permit ®Yes pNo Requested but not required 2. General Location (USGS) Map shows plant ®Yes pNo, lines —of discharge Part II(A)(1)(a) to water of State pYes KNo, Stream labeled ®Yes ®No, Latitude and longitude ®Yes ''piJo 3. Narrative Description of Practices ®Yes pNo!M Part II(A)(1)(b) 4. ite ma ®Yes Shows flows &areas served with arrows and Part II(A)(1)(c) _pNo % impervious surface ®Yes pNo, buildings ®Yes pNo, process areas ®Yes pNo, disposal areas ®Yes pNo, drainage structures ®Yes pNo, existing BMPs such as secondary containment p_Yes _pNo, list of potential pollutants ®Yes pNo Comments: 5. List of significant spills in last 3 years or certif. if none ®Yes pNo none Part II(A)(1)(d) RRO called? 'Yes'ONo 6. SW outfalls have been evaluated for process water ®Yes pNo . Part 11(A)(1)(e) 7. Feasibility of Changing Practices ®Yes pNo ' Part II(A)(2)(a) 8. Secondary Containment ®Yes pNo n ': Schedule needed?'Yes pNo Part II(A)(2)(b) Records of Draining Containment, Observations Made ®Yes pNo 9. BMP Summary ®Yes pNo ESEPart II(A)(2)(c) 10. SPRP Plan ®Yes pNo, Responsible personnel still employed here? ®Yes pNoo a Part II(A)(3) 11. PM and Housekeeine Plan ®Yes pNo P Record of Inspections? ®Yes pNo Part Il(A)(4) 12. Employee training ®Yes pNo — for everybody ®Yes pNo TRr' Part II(A)(5) 13. Responsible parties, chain of command page ®Yes pNoi Part II(A)(6) 14. Plan updated/reviewed annually ®Yes pNo Part II(A)(7) 15. Stormwater Facility Inspection Program pYes pNo Remmd`er,chatfeundertfntt-cvr Part II(A)(8) 16. This Plan Has Been Implemented (documents in manual, Part II(A)(9) employees show awareness ®Yes pNo Comments Sampling and Analytical Data Part II(C) All Stormwater and Process Water is Recycled (IiC(3)1 pYcs ®No Rain Gauge on site (not required)'Yes pNo If Q 0 yr storm and overflows, sample. If >I0 yr storm, sampling not required. How do they know if 10 yr storm or not'? Record of an overflow pYes pNo Details !f not all recycled, what is allowed to discharge? Vehicle Cleaning (IIC2) F] Recycle overflow (IIC3 above) [A Wetting of Aggregate (IIC4)Q Mixing drum cleanout (IIC5) E] Note: this checklist does not take the place of your permit. You are fully responsible for following the permit. For the topics checked in last question, Analytical data present ®Yes pNo, Compliant? ®Yes pNo Details: Qualitative Monitoring performed semiannual ly-®Yes-pNo-Wet-EJ—Dry-B------Part-II(F) --:— - Stormwater not combined with process wastewater- general runoff Partll(C)(1) Analytical data ®Yes No, Chain of Custody pYes [jNo, Qualitative Monitoring performed semiannually (Section F) ®Yes pNo, Wet M Dry If using cutoff policy, how many sample rounds Cutoff Concentrations met pYes pNo f yvEver have a Bypass? 'Yes pNo (III (C)(4)al &2) Notification given? pYes pNo Outdoor Inspection located all discharge points ®Yes pNo No of areas served 2 Sample points appropriate ®Yes `pNo Location if different from discharge point Housekeeping: Trash pYes ®No Dust'Yes ®No Take pH pYes ®No Value(s) Take photos pYes ®No Containment Area satisfactory ®Yes pNo, Loose drums pYes ®No, Locked drain ®Yes ENO Concrete disposal pile comments Smell egularlydealttli Inspection Summary Comments Gompl iant,�;good�rdocumentatn;V al1r�A-OK Recommendations: Requirements: Letter is to go to: -.. . Name LarySpence Title Address Helpful Information at htto-//h2o con state nc us/su/Manuals Factshects.htrn Note: this checklist does not take the place of your permit. You are fully responsible for following the permit. United States Environmental Protection Agency EPA Washington, D.C. 20460 Form Approved. OMB No. 2040-0057 Water Compliance Inspection Report Approval expires 8.31-98 Section A: National Data System Coding (i.e., PCS) _ Transaction Code _ NPDES _ yr/mo/day Inspection Type Inspector Fac Type 1 I N 2 151 31 NCG140128 111 12I 03/04/21 1 17 161„I 19 [21 20 L LJ LJ IJ lJ Remarks 21,111111111111111111111��1IIIIIIIIIIIIIIIIIIII161 Inspection Work Days Facility Self -Monitoring Evaluation Rating B1 CA —--------- ----- ---------- Reserved ------------------- 67 1 69 70 1 3 1 71 I liI 72 I„ I 73 � 74 75I I I I I I I 180 LJ LJ Section B:FacilityData Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11:00 AM 03/04/21 99/08/01 Southern Equipment Co -Gran #13 Exit Time/Date Permit Expiration Date 100-A 2211nd SC Butner NC 27509 11L55 All 03/04/21 04/07/31 Names) of Onsite Representative(s)/Titles(s)/Phone and Fax Numbers) Other Facility Data Steven Ray/// Steven Ray/// Name, Address of Responsible Official/title/Phone and Fax Number Contacted Lyman Austin,3610 Bush St Raleigh NC 27609//919-790-1520/ IJo Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Records/Reports Storm water Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) See Attached Letter Names) and Signatures) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Myrl Nisely RRO WQ//919-571-4900/919-571-4718 Signature of Management O A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. q State of North Carolina tDepartment of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Kerr T. Stevens, Director JLA� NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES July 26,1999 LYMAN AUSTIN SOUTHERN EQUIPMENT CO INC-GRANVILLE #13 3610 BUSH STREET RALEIGH, NC 27609 Subject: Reissue - NPDES Stormwater Permit Southern Equipment Co Inc -Granville #13 COC Number NCG140128 Dear Permittee: Granville County In response to your renewal application for continued coverage under general permit NCG140000, the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983. The following information is included with your permit package: * A copy of general Stormwater permit NCG140000 * A Stormwater Pollution Prevention Plan (SPPP) Certification Form. Completion of this form is required to certify that you have developed and implemented the SPPP as per the conditions of the permit. This form must be completed and returned to the Division within 30 days of receipt of this letter. DO NOT SEND the SPPP with the signed form. * Five copies of the Analytical Monitoring form and five copies of the Qualitative Monitoring form * A copy of a Technical Bulletin for the general permit which outlines changes in the permit, key requirements, and addresses frequently asked questions * A Certificate of Coverage Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package please contact Tony Evans of the Central Office Stormwater and General Permits Unit at (919) 733-5083, ext. 584 Sincerely, for Kerr T. Stevens cc: Central Files Stormwater and General permits Unit Files Raleigh Regional Office 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 Fax 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140128 STORMWATER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, SOUTHERN EQUIPMENT CO INC-GRANVILLE #13 is hereby authorized to operate a process wastewater treatment system, and is hereby authorized to discharge process wastewater and stormwater from a facility located at SOUTHERN EQUIPMENT CO INC-GRANVILLE #13 100-A 22ND STREET BUTNER GRANV ILLE COUNTY to receiving waters designated as Butner MSSS to a UT of the Neuse River in the Neuse River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, V, and VI of General Permit No. NCG140000 as attached. This certificate of coverage shall become effective August 1, 1999. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day July 26, 1999. for Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission State of North Carolina 0 Department of Environ lHealth of Natu ral 0 nags enC5�oFE\G� • Division • James B. Hunt, Jr., Govern Jonathan B. Howes, Secreta Q�P� p E H N A. Preston Howard, Jr., P.E., ' March 10, 1995 Mr. Larry Spence Southern Equipment Co., Inc. 3610 Bush Street Raleigh, INC 27609 Subject: Certificate of Coverage (COC) COC NCG140128 Southern Equipment Co., Inc. Granville County Dear Mr. Spence: On March 3, 1995 the Division of Environmental Management (Division) issued COC NCG140128 to Ready Mixed Concrete Company. The Division made an error when preparing the Certificate of Coverage (Certificate). Accordingly, we are forwarding herewith a change to the subject Certificate to correct the error. The Certificate change includes the correct facility owner, Southern Equipment Co., Inc. covered by the Certificate. Please find enclosed an amended Certificate which you should use in place of the original ::You should discard the old Certificate. The Certificate change is issued pursuant to the requirements of North Carolina General Statutes 143-215.1 and the Memorandum of Agreement between North Carolina and the U. S. Environmental Protection Agency. If you have any questions concerning this Certificate change, please contact Antonio Evans at 919/733-5083, Ext. 584. Sincerely, Preston ard, Jr., P.E. cc. Raleigh Regional Office Central Files P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper �4. STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH,.AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No, NCG140128 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with die provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Southern Equipment Co., liu7. is hereby authorized to discharge sionmwater from a facility located at Ready Mixed Concrete Company 100-A 22nd Street Butner, NC Granville County to receiving waters designated as City of Butner Storm Sewer to an unnamed tributary to Neuse River in the Neuse River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Pans I, II, Ill and IV of General Permit No. NCGI40000 as attached. This certificate of coverage shall become effective March 3, 1995. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day March 3, 1995. Gt- Preston H war , Jr., P.E., Director Division of tvironmental Management By Authority of the Environmental Management Commission State of North Carolina Department of Health and Na 0 Raleigh, NC 27609 Dear Larry Spence: ronment, Resources rental Management Co Inc. P.E., Director March 3, 1995 A E 40 le IDEHNR Subject: General Permit No. NCG140000 Southern Equipment Co Inc. COC NCG140128 Granville County In accordance with your application for a stormwater discharge permit received on December 12, 1994, we are forwarding herewith the subject state - NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1983. The stormwater permit you are receiving, NCG 140000, does not permit wasting concrete, dumping excess concrete, directly into storm sewer outfalls or into waters of the state. Any facility which either dumps excess concrete or washes excess concrete into storm sewers or waters of the state will be operating in direct violation to both the terms of this permit and the North Carolina General Statutes. Such a discharge shall be considered an illegal discharge and may subject the owner to enforcement actions in accordance with North Carolina General Statutes 143-215.6A If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings Post Office Drawer 27447, Raleigh, North Carolina 27611-7447. Unless such demand is made, this decision shall be final and binding. Please take notice that this certificate of coverage is not transferable. Part II, 13.2. addresses the requirements to be followed in case of change in ownership or control of this discharge. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any question concerning this permit, please contact MR. ANTONIO EVANS at telephone number 919/733-5083, extension 584. cc: Raleigh Regional Office Mr. Roosevelt Childress, EPA Sincerely, f,rigjinal Signed By Gcleen H. Sullins A. Preston Howard, Jr. P.E. P.O. Box 29535, Raleigh, North Carolina 27626-0535 An Equal Opportunity Affirmative Action Employer Telephone 919-733-7015 FAX 919-733-2496 50% recycled/ 10% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140128 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Ready Mixed Concrete Company is hereby authorized to discharge stormwater from a facility located at Ready Mixed Concrete Company 100-A 22nd Street Butner, NC Granville County to receiving waters designated as City of Butner Storm Sewer to an unnamed tributary to Neuse River in the Neuse River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1,1I, III and IV of General Permit No. NCG140000 as attached. This certificate of coverage shall become effective March 3, 1995. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day March 3, 1995. Original Sinned By Colleen R Sullins A. Preston Howard, Jr., P.E., Director Division of Environmental Management By Authority of the Environmental Management Commission 1 A 11 \ 1 � 10, BM 386 urd h Center '°02 I ~ _ r FE Vremb � _Pen -001 Side- olub i�� /1 .04 2080000 FEET 36°07'30!,— 103 U(/NMAMI3Ml. 7g°45 the Geological Survey Mapped, edited, and published by M�• control by USGS, NOSINOAA, USCE,and North Carolina Geodetic Survey cN g1 \05F' Topography by photogrammetric methods from aerial photographs , taken 1974. Field checked 1974 ' 124 MILS 1-1 <i Projection and 10,000 foot grid ticks: North Carolina coordina e I I94MILS