Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NCG140110_COMPLETE FILE - HISTORICAL_20071011
STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /v u& I! Q l 1 0 DOC TYPE [�/HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ Jti b I to I' YYYYM M DD Commercial Ready Mix Products, Inc. P.O. Box 189 Winton, North Carolina 27986 Office Phone: (252) 358-5461 Fax: (252) 358-4912 October 11. 2007 Sent Via Certified Mail — Return Receipt Requested Mr. Al Hodge, Supervisor North Carolina Department of Environment and Natural Resources Surface Water Protection Section 943 Washington Square Mall Washington, North Carolina 27889 Subject: RESPONSE TO NOTICE OF VIOLATION DATED SEPTEMBER 27, 2007 COMMERCIAL READY MIX PRODUCTS, INC. PERMIT NUMBER NCG140110 CHOWAN COUNTY Ac�� /1/0i/6 Dear Mr. Hodge: OCT 7 201l, Ora�� Nov Zoos . P�. This letter serves as a written response to the Notice of Violation (NOV) issued by your office and dated September 27, 2007. Commercial Ready Mix Products, Inc. (CRMP) has hired an environmental engineering firm to assist us with the proper implementation of and compliance with NPDES Stormwater General Permit NCG140110. The firm has been retained to address the permit violations observed during the September 20, 2007 inspection conducted by Mr. Ed Warren from the Division of Water Quality. Listed below are the permit violations in italic followed by the corrective actions that will be conducted by CRMP. 1. Stormwater Pollution Prevention Plan (SPPP) A Stormwater Pollution Prevention Plan (SPPP) has been developed and recorded but not fully implemented. Specifically, all necessary secondary containment is not provided and employee training has not been preformed. CRMP Inc. has determined that some site improvements are detrimental to meeting the necessary requirements for SWQ on the subject of containment and runoff. These improvements would possibly require an update to our current SPPP. In order to implement these improvements, we would like to request a completion date of May 1, 2008 to have this issue in compliance. CRMP INC. Response to September 2007 NOV Commercial Ready Mix Products, Inc. Chowan County, NC October 8, 2007 Page 2 CRMP plant managers have attended SPPP training at the Ahoskie Plant during the September 20, 2007 inspection and will provide employee training at each of its facilities in the immediate future. Proper documentation of employee training will be kept at each facility and employee files at the corporate office. 2. Qualitative Monitoring Qualitative monitoring has not been conducted and recorded in accordance with permit requirements. The environmental engineering firm will assist plant managers in qualitative monitoring and record keeping. This will be completed during a one day training session at each facility. The annual non-stormwater discharge certification, semi-annual facility inspection and semi-annual visual monitoring of outfalls will be conducted during this training session. This training session is scheduled for early November 2007. 3. Analytical Monitoring Analytical monitoring has not been conducted and recorded in accordance with permit requirements. Sampling procedures and reporting requirements will be reviewed during the one day training session conducted by the environmental engineering firm. CRMP will collect water samples during the next representative storm event. The annual DMR will be submitted to DWQ upon receipt of analytical results. We appreciate your patience as we work to complete these tasks. If you have any questions or would like to contact me, please give me a call at 252-358-5461. Sincerely, COMMERCIAL READY MIX PRODUCTS, INC. -C Tommy ChharYes n rF9 0�f p g D b--07 �Or Y September 27, 2007 CERTIFIED MAIL 7007 0220 0003 1483 2551 RETURN RECEIPT REQUESTED Charles R Harrell Commercial Ready Mix Products PO Box 189 Winton NC 27986 Subject: NOTICE OF VIOLATION NOV-2007-PC-0626 Permit No. NCG140110 Commercial Ready Mix Products Chowan County Dear Mr. Harrell: Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Coleen Sullins, Director Division of Water Quality Ed Warren from the Washington Regional Office of the Division of Water Quality conducted a site inspection of your facility, Commercial Ready Mix Products located at 302 Hicks St., Edenton, Chowan County, North Carolina on September 20, 2007. The site drains to an Unnamed Tributary of Queen Anne Creek, Class C-NSW waters located in the Chowan River Basin. The site visit and file review revealed that the subject project is covered by NPDES Stormwater General Permit NCG140110. The facility was found to be in NONCOMPLIANCE with the NPDES Permit. The following observations and/or permit conditions violations were noted during the Division of Water Quality inspection: 1) Stormwater Pollution Prevention Plan (SPPP) A Stormwater Pollution Prevention Plan (SPPP) has been developed and recorded but not fully implemented. Specifically, all necessary secondary containment is not provided and employee training has not been performed. 2) Qualitative Monitoring Qualitative monitoring has not been conducted and recorded in accordance with permit requirements. 3) Analytical Monitoring Analytical monitoring has not been conducted and recorded in accordance with permit requirements. (Please see the attached addendum for information about your permit). Other Observations: 1. The required SPPP was completed recently but not being fully implemented. The analytical and qualitative monitoring has not been completed. Part Il, Section B and C of your permit outlines the requirements for analytical and qualitative monitoring. Failure to comply with the conditions contained in your permit is considered to be a violation. 2. You should read your entire permit and be aware of what is required in it. It is your responsibility as the permit holder to read and understand what your responsibilities are. 3. You are reminded that you must keep a copy of your permit and certificate of coverage on site. You had a copy on the inspection date. Please provide this Office with a written response within fifteen (15) days of your receipt of this letter. Please include anything you would like submitted to DWQ to address the violations observed on site. No�thCarolinn AWitrn!/y North Carolina Division of Water Quality Washington Regional Office Phone (252) 946-6481 Customer Service Internet: www.ncwaterqualiry.org 943 Washington Square Mall, Washington, NC 27889 FAX (252) 946-9215 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycled110% Post Consumer Paper Thank you for your attention to this matter. This Office requires that the violations, as detailed above, be properly D resolved. These violations and any future violations are subject to a civil penalty assessment of up to $25,000.00 per day for each violation. Should you have any questions regarding these matters, please contact Ed Warren at (252)948-3924 Si cerelly��� AI Hodge, Regional Supervisor Surface Water Protection Section Washington Regional Office Division of Water Quality Addendum Cc: WaRO — Water Quality Danny Smith — NPS-ACO Unit Water Quality Central Files ADDENDUM The National Pollutant Discharge Elimination System (NPDES) program was established under the federal Clean Water Act and then delegated to the Division of Water Quality for implementation in North Carolina. The NPDES permitting program for stormwater discharges was established in 1990. Phase I focuses on site and operations planning to reduce pollutant sources. Through the NPDES permitting program industrial facilities that fall into one of the subject ten categories are required to obtain permit coverage under a general permit or an individual permit, depending upon the facilities SIC code and the industrial activity occurring at the facility. There are currently 19 active general stormwater permits in North Carolina. One condition that is applicable to both the general permits and individual stormwater permits is the requirement to develop and implement site -specific comprehensive stormwater pollution prevention plans (SPPP). These plans are required to include a comprehensive evaluation of the site and operations to reduce pollutant sources and prevent pollutant discharge. Copies of the general permits and accompanying documents can be accessed from the following webpage: http://h2o.enr.state.nc.us/su/Forms Documents.htm Permit text, technical bulletins, discharge monitoring forms, and a Notice of lntent-[which is -the application of for coverage -under a NPDES General-Stormwater Permit] can -be found at this - web site. The following items are a subset of permit requirements and are listed to assist you and help bring your attention to certain permitting issues, process and condition requirements of your permit. That said, please see the above mentioned web site in order to obtain a copy of the permit such that you may fully comply with all the conditions therein. Failure to properly comply with conditions of the permit, like those bulleted below, constitutes violations and are subject civil penalty assessment of up to $25,000.00 per day. • Industrial facilities that fall into one of the subject ten categories are required to obtain permit coverage under a general NPDES stormwater permit or an individual NPDES stormwater permit • All persons desiring to have facilities covered by a General Permit must register with the Division of Water Quality (DWQ) by the filing of a Notice of Intent (NOI) and Applicable Fees. • This Notice of Intent (NOI) must be submitted and a Certificate of Coverage issued prior to any discharge of stormwater associated with the industrial activity, process wastewater, and/or mine dewatering. • Once the Notice of Intent is received. DWQ will review and determine whether a Certificate of Coverage (COC) may be issued. If this Certificate of Coverage is issued the facility is covered by the General Permit. That is, the permittee is authorized to discharge stormwater, process wastewater, and/or mine dewatering pursuant to the type of General Permit until the permit expires or is modified or revoked. • Any other point source discharge to surface water of the state is prohibited unless it is an allowable non- stormwater discharge or is covered by another permit, authorization or approval. • There are currently 19 active general permits. Permit conditions vary accordingly; however, most of the permits have following condition requirements (you must read your entire permit to ensure full compliance): o Development and compliance with the Stormwater Pollution Prevention Plan o Collection, reporting, and recording of Analytical Monitoring o Collection, reporting and recording of Qualitative Monitoring o Collection, reporting and recording of Vehicle Maintenance Monitoring o Records - Visual monitoring shall be documented and records maintained at the facility along with the Stormwater Pollution Prevention Plan. Copies of the analytical monitoring results shall also be maintained on -site. The Permittee shall retain records of all monitoring information, including all calibration and maintenance records and all original strip chart recordings for continuous monitoring instrumentation, and copies of all reports required by this general permit for a period of least 5 years for the date of the sample measurement, report or application. o Expiration - The permittee is not authorized to discharge after the expiration date of the general permit. In order to receive automatic authorization to discharge beyond the expiration date, the permittee shall submit forms and fees as are required by the agency authorized to issue permits no later than 180-days prior to expiration date. Any permittee that has not requested renewal at least 180 days prior to expiration, or any permittee that does not have a permit after the expiration and has not requested renewal at least 180 days prior to expiration, will be subject to enforcement. Failure to renew your permit is a violation. Transfer — The Certificate of Coverage (COC) issued pursuant to this general permit is not transferable to any person expect after notice to and approval by the Director. The Director may require modification or revocation and reissuance of the Certificate of Coverage to change the name and incorporate such other requirements as may be necessary under the Clean Water Act, The Permit is NOT transferable. o Name Change, Closure or Facility Ownership change — Permittee is required to notify the Division in writing in the event the permitted facility is sold or closed. The Division of Water Quality views changes of name or ownership as a modification that requires the Director's approval and reissuance of the permit. Name and ownership changes required you to complete a Name/ownership Change Form from the Division and mail it back to the Division of Water Quality along with all appropriate information. o Proper Operation and Maintenance is a requirement of the permit. Compliance Inspection Report Permit: NCG140110 Effective: 08/01/04 Expiration: 07/31/09 Owner: Commercial Ready Mix Products SOC: Effective: Expiration: Facility: Commercial Ready Mix Products County: Chowan 302 Hicks St Region: Washington Edenton NC 27932 Contact Person: Charles R Harrell Title: Phone: 919-482-3298 Directions to Facility: System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): 24 hour contact name Charles R Harrell Phone: 252-358-5461 On -site representative Thomas Charles Phone: On -site representative Tom Sawyer Phone: Related Permits: Inspection Date: 09/20/2007 Entry Time: 08:30 AM Exit Time: 10:30 AM Primary Inspector: Garland E WarrenC Phone:('�y�'-,��` Secondary Inspector(s): \/llT1^^�� Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Ready Mix Concrete StormwaterNdastewaler Discharge COC Facility Status: ❑ Compliant A Not Compliant Question Areas: 0 Storm Water (See attachment summary) Page: 1 Permit: NCG140110 Owner - Facility: Commercial Ready Mix Products Inspection Date: 09/20/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: The facility was determined to be in NONCOMPLIANCE with NPDES Permit No. NCG140110 for the following reasons: -All necessary secondary containment is not built and available. -Employee training has not been provided and documented. -Qualitative Monitoring has not been performed semi-annually. -Analytical Monitoring has not been performed. It was noted during the inspection that the facility has recently obtained a Stormwater Pollution Prevention Plan and is in the process of implementing the Plan. Company representatives indicated that the discrepancies listed above would be addressed and performed in the immediate future. It was recommended that the facility schedule training, develop a schedule for providing the necessary secondary containment, perform Qualitative Monitoring at the next rain event and contact a commercial laboratory to obtain items necessary to conduct Analytical Monitoring during the next representative rainfall event. Facility was reminded of requirement to perform analytical monitoring during the first and last year of the permit term regardless of cut-off concentrations and to submit the results of the monitoring during the last year of the permit term with the permit renewal application. Page:2 Permit: NCG140110 Owner - Facility: Commercial Ready Mix Products Inspection Date: 09/2012007 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ® 0 0 0 # Does the Plan include a General Location (USGS) map? S 0 Cl 0 # Does the Plan include a "Narrative Description of Practices"? ■ 0 Cl 0 # Does the Plan include a detailed site map including outfall locations and drainage areas? ® 0 0 0 # Does the Plan include a list of significant spills occurring during the past 3 years? ® 0 0 0 # Has the facility evaluated feasible alternatives to current practices? ® Cl 0 0 # Does the facility provide all necessary secondary containment? 0 ■ 0 0 # Does the Plan include a BMP summary? ® 0 0 0 # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ®❑ 0 Cl # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ® 0 0 0 # Does the facility provide and document Employee Training? 0 0 0 # Does the Plan include a list of Responsible Party(s)? ® 0 0 0 # Is the Plan reviewed and updated annually? Cl ■ ❑ 0 # Does the Plan include a Stormwater Facility Inspection Program? ■ 0 0 0 Has the Stormwater Pollution Prevention Plan been implemented? Cl ■ 0 0 Comment: Facility has recently obtained a Stormwater Pollution Prevention Plan but has not fully implemented all of the Plan components. The Plan has not been reviewed and updated annually since it was recently developed. Company has not performed Plan arequired employee training at this facility. However, company representatives were attending training on the day of the inspection and plan on providing employee training at each of its facilities in the immediate future. Facility has secondary containment for fuel storage, but not for chemical storage areas. According to the Plan, all secondary containment will be provided in the immediate future. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? 0 m 0 0 Comment: Facility has not performed Qualitative Monitoring to date but will begin in the immediate future. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? 0 ® 0 0 # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? 0 0 0 0 Comment: Facility has not performed Analytical Monitoring to date but will in the immediate future. Permit and Outfalls Yes No NA NE Page: 3 Permit: NCG140110 Owner • Facility: Commercial Ready Mix Products Inspection Date: 09/20/2007 Inspection Type: Compliance Evaluation Reason for Visit: Routine # Is a copy of the Permit and the Certificate of Coverage available at the site? # Were all outfalls observed during the inspection? # If the facility has representative outfall status, is it properly documented by the Division? # Has the facility evaluated all illicit (non stormwater) discharges? Comment: The recently completed Plan contains a form to evaluate non stormwater discharges but facility has not completed task to date. Facility has eliminated Outfall #1 by building a catch basin to collect stormwater from the applicable drainage area for recycling. The Plan will be amended to reflect this basin and practice. There appeared to be a small amount of concrete waste in the receiving ditch for Outfall #1. It appeared that it had gradually accumulated over the years and the present owners indicated that it was there when they bought the site. The aforementioned catch basin should eliminate the potential for concrete waste products to be discharged to this ditch. M 0 0 0 ®❑ ❑ ❑ ❑❑M0 ❑M00 Page: 4 Stormwater Inspection Checklist for NCG 140000 Type of Visit: ® Compliance Inspection/Program ❑Technical Assistance ❑ Recon Location: 302 Hicks St, Edenton, NC Facility Name: Commercial Ready Mix Products COC# NCG140110 Date: 09/20/2007 Time in: 8:30 am Time Out 10:30 am Name/Title of contact(s): Thomas Charles, Tom Sawyer Stream Name: UT of Queen Anne Creek Classification: C-NSW RiverBasin: Chowan 1. Are stormwater and wastewater isolated from one another, ie: distinct and separate outfalls? 2. For wastewater (or combined SW and WW), is there a means of attenuating TSS? YES NO NA NE 3. Is there a means for attenuating pH? ❑ ® ❑ ❑ 4. Do process water discharges at the outfall (s) meet pH 6.9? (Check with DWQ Meter) ❑ ❑ ® ❑ 5. Do stormwater discharges (not process water) meet pH 6.9 at the outfall(s)? ❑ ❑ ❑ 6. Is water used for appropriate purposes (tanks on trucks, new batches, but not lawns? or toilets)? ® ❑ ❑ ❑ 7. Do secondary containment structures have integrity (not damaged or cracked)? ® ❑ ❑ ❑ 8. Have I conveyed the requirement of an Authorization to Construct for any new or remodeled wastewater treatment unit? ® ❑ ❑ ❑ 9. Were pictures taken during the inspection? ❑ ® ❑ ❑ Comments: There was no discharge on the day of the inspection. There is no means for attenuating pH. All stormwater flows across the concrete and rock areas of the lot, is collected in a storm drain on site and piped to the unnamed tributary, There are no grass swales or other means for attenuating pH on this site. `2 Inspector Name: � ���� Date: L USPS --track R Confirm httpJArkcnfrnl I .snli.usps.cons/P'I-Slnternet W eb/InterLabel l nquiry.do UNITED STATES. 2 POSTAC SERVICEe Track & Confirm Search Results Label/Receipt Number: 7007 0220 0003 1483 2551 Status: Delivered Your item was delivered at 9:41 AM on October 1, 2007 in WINTON, NC 27986. Additional Dofails> Return to USPS.cam Hamo> Notification Options Home I Help I Sign In Track & Confirm FAOs Track & Confirm Enter Label/Receipt Number. Go> Track & Confirm by email Get current event information or updates for your item sent to you or others by email. Gp> IJ POSTAL INSPECTORS site map contact us government services jobs National & Premier Accounts Preservinq the Trust Copyright© 1999-2004 USPS, All Rights Reserved. Terms of Use Privacy Policv ' ■ Complete. items 1, 2, and 3. Also complete Item 4 if Restricted Delivery Is desired. ■ Print your name and address on the reverse so that we can return the card to you. ■ Attach this card to the back of the mailpiece or on the front if space permits. 1. Article Addressed to: CHARLES R HARRELL COMMERCIAL READY MIX PRODUCTS PO BOX 189 WINTON NC 27986 ❑ Agent Ived Dy (P�npd Nsme) C. Date of Delit a n �L r �V 2icf s 1 D. Is delivery address different from Item 1? ❑ Yes If YES, enter delivery address below: ❑ No 3. Service Type ❑ Certified Mall ❑ Express Mail ❑ Registered ❑ Return Receipt for Merchandise ❑ Insured Mall ❑ C.O.D. 4. Restricted Delivery? (Extra Fee) ❑ Yes 2. Article Number 7007 0220 0003 1483 2551 (Ransfer from service IabeQ' , PS Form 3811, February 2004 Domestic Return Recelpt 102595-02-M-1540 I of 1 10/23/2007 10:39 AM N 5 r (1J Total Postage 8 Fees - - - C rWnTrol—CHARLES R HARRELL o NjwpF COMMERCIAL READY MIX PRODUCTS m P0&nl PO BOX 189 �� WINTON NC 27986 State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Kerr T. Stevens, Director 1� NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES July 26, 1999 THOMAS C WILSON COMMERCIAL READY MIX PRODUCTS, INC. P.O. BOX 27326 RALEIGH, NC 27611 Subject: Reissue - NPDES Stormwater Permit Commercial Ready Mix Products, Inc. CDC Number NCG140110 Dear Permittee: Chowan County In response to your renewal application for continued coverage under general permit NCG 140000, the Division of Water Quality (DWQ) is forwarding herewith the reissued Stormwater general permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983. The following information is included with your permit package: * A copy of general Stormwater permit NCG 140000 * A Stormwater Pollution Prevention Plan (SPPP) Certification Form. Completion of this form is required to certify that you have developed and implemented the SPPP as per the conditions of the permit. This form must be completed and returned to the Division within 30 days of receipt of this letter. DO NOT SEND the SPPP with the signed form. * Five copies of the Analytical Monitoring form and five copies of the Qualitative Monitoring form * A copy of a Technical Bulletin for the general permit which outlines changes in the permit, key requirements, _ and addresses frequently asked questions * A Certificate of Coverage Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree... If you have any questions regarding this permit package please contact Tony Evans of the Central Office Stormwater and General Permits Unit at (919) 733-5083, ext. 584 Sincerely, for Kerr T. Stevens cc: Central Files Stormwater and General permits Unit Files Washington Regional Office p �IG1��f� ICI AUG - 5 1999 WASHINGTON REGIONAL OFFICE DWO 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 Fax 919-733-9919 An Equal Opportunity Affirmative Action Employer 50 % recycled/ 10 % post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140110 STORMWATER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, COMMERCIAL READY MIX PRODUCTS, INC. is hereby authorized to operate a process wastewater treatment system, and is hereby authorized to discharge process wastewater and stormwater from a facility located at COMMERCIAL READY MIX PRODUCTS, INC. 302 HICKS ST EDENTON CHOWAN COUNTY to receiving waters designated as a UT of Queen Armes Creek in the Chowan River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, 11, III, IV. V. and VI of General Permit No. NCG140000 as attached. This certificate of coverage shall become effective August 1, 1999. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signcd this day July 26, 1999. for Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission 17 iT State of North darolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Kerr T. Stevens, Director Mr. Charles R. Harrell Commercial Ready Mix Products, Inc. Post Office Box 190 Cofield, North Carolina 27922 Dear Mr. Harrell: �r NCDENR April 9, 1999 Subject: Permit Modification -Name and Ownership Change Commercial Ready Mix Products, Inc. Permit No. NCG 140110 (formerly Ready Mix Concrete Co.) Chowan County In accordance with your request received April 7, 1999, the Division is forwarding the subject permit. The changes in this permit are only with regard to a name and an ownership. All other terms and conditions in the original permit remain unchanged and in full effect. This permit modification is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between North Carolina and the U. S. Environmental Protection Agency dated December 6, 1983. This permit does not affect the legal requirement to obtain other permits which may be required by the Division of Water Quality or permits required by the Division of Land Resources, Coastal Area Management Act, or any other Federal or Local government permit that may be required. If you have any questions concerning this permit, please contact Ms. Vanessa Wiggins at telephone number (919)733-5083, extension 520. Sincerely, ORIGINAL SIGNED BY WILLIAM C. MILLS Kerr T. Stevens cc: Central Files Washington Regional -Office, Water_Quality Section- Stormwater and General Permits Unit Point Source Compliance Unit APR 14 1999 WASHINGiON REGIONAL OFFICE P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper PLUCE STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG140000 CERTIFICATE OF VERA E No. 140110 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Poliution Control Act, as amended, Commercial Ready Mix Products, Inc. is hereby authorized to discharge stormwater from a facility located at Commercial Ready Mix Products, Inc. 302 Hicks Street Edenton, NC Chowan County to receiving waters designated as an unnamed tributary to Queen Anne Creek in the Chowan River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, 11, 111 and IV of General Permit No. NCG 140000 as attached. This Certificate of Coverage shall become effective April 9, 1999. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day April 9, 1999. ORIGINAL SIGNED BY WILLIAM C. MILLS Kerr -1 . Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission State of North Carolina 1�7 Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Kerr T. Stevens, Director Mr. Charles Harrell Commercial Ready Mix Products, Inc. Post Office Box 1009 Mountain Home, North Carolina 28758 1\ !: ' NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES March 30, 1999 FILAPR - 5 1999 GTON REGIONAL OFFICE Subject: NPDES Stormwater Name/Ownership Change Commercial Ready Mix Products, Inc. NCG140110 Chowan County Dear Mr. Harrell: On March 29, 1999, the Division of Water Quality received letter requesting a name/ownership change for NPDES Stormwater Permit No. NCG140110. The following was not received: Completed and signed Name/Ownership Change form. X Copy of a legal documentation (required only if it is ownership change) The submittal is considered incomplete. Therefore, the Division of Water Quality is not able to process your submittal until the required information has been submitted. Your letter and other attachments are being returned to you herein for resubmittal. If you have any questions, please contact Vanessa Wiggins at (919) 733-5083 ext. 520. Sincerely, Bradley Bennett, Supervisor Stormwater Group NPDES Unit Attachments cc: Washington Regional-Officel P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper �, 'r. ��. _ ��1%J lira ' r 6�0(u.;triif.ik State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary A. Preston Howard, Jr., P.E., Director March 15, 1999 CERTIFIED MAIL RETURN RECEIPT REQUESTED Yam:riIS►:�YyrJINWO]`.I READY MIXED CONCRETE CO - CHOWAN P.O. BOX 27326 RALEIGH, NC 27611 Dear Permittee: AA NCDENR NORTH CAROLINA DEPARTMENT OF D11G����]C� D LJ U MAR 16 1999 WASHINGTON REGIONAL OFFICE DWD Subject: FINAL NOTICE - NPDES Stormwater Permit Renewal Ready Mixed Concrete Co - Chowan COC Number NCG 140110 Chowan County Your facility is currently covered for stormwater discharge under General Permit NCG 140000. This permit will expire on July 31, 1999. North Carolina General Statute 143.215.1(c) requires that an application for permit coverage renewal be filed in a timely manner. A prior notice of renewal was sent for this site on January 12, 1999. To date, no response has been received by the Division of Water Quality (DWQ). In order to assure your continued coverage under the general permit, you must apply to DWQ for renewal of your permit coverage. Enclosed you will find a general permit renewal application form. This form serves two purposes. First, it is an application for renewal of your permit coverage. Second, it serves as an invoice for the $80.00 permit fee. The application must be completed and returned with the required fee by April 5, 1999 in order to assure continued coverage under the general permit. Recent legislation modified the fee structure for DWQ permits. Your general permit fee has been changed to an annual fee of $80.00. A copy of the new fee schedule is enclosed in this package. Failure to request renewal by April 5, 1999 will result in a civil assessment of at least $250.00. Larger penalties may be assessed depending on the delinquency of the request. Discharge of stormwater from your facility without coverage under a valid stormwater NPDES permit would constitute a violation of NCGS 143-215.1 and could result in assessments of civil penalties of up to $10,000 per day. If you have any questions regarding the permit renewal procedures please contact Robert Tankard of the Washington Regional Office at 252-946-6481 or Tony Evans of the Central Office Stormwater Unit at (919) 733-5083, ext. 584 Sincerely, Bradley Bennett, Supervisor Stormwater and General Permits Unit cc: Central Files Washington, Regional'Office j P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recyded/ 10% post -consumer paper State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director Thomas C Wilson Ready Mixed Concrete Co 302 Hicks St Edenton, NC 27932 Dear Thomas C Wilson: February 24, 1995 & LT IT [D EHHNR WASH NGTONEOFFICE MAR 0 1 1995 D. E M. Subject: General Permit No. NCG10000 Ready Mixed Concrete Cc COC NCGI40110 Chowan County In accordance with your application for a stormwater discharge permit received on November 28, 1994, we are forwarding herewith the subject state - NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1983. The stormwater permit you are receiving. NCG140000, does not permit wasting concrete, dumping excess concrete, directly into storm sewer outfalls or into waters of the state. Any facility which either dumps excess concrete or washes excess concrete into storm sewers or waters of the state will be operating in direct violation to both the terms of this permit and the North Carolina General Statutes. Such a discharge shall be considered an illegal discharge and may subject the owner to enforcement actions in accordance with North Carolina General Statutes 143-215.6A If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings Post Office Drawer 27447, Raleigh, North Carolina 27611-7447. Unless such demand is made, this decision shall be final and binding. Please take notice that this certificate of coverage is not transferable. Part II, B.2. addresses the requirements to be followed in case of change in ownership or control of this discharge. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any question concerning this permit, please contact MR. ANTONIO EVANS at telephone number 919/733-5083, extension 584. Sincerely, original Signed By Coieen H. Sullins A. Preston Howard, Jr. P.E. cc: Washington Regional Office Mr. Roosevelt Childress, EPA P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-7015 FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG1401U STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended Ready Mixed Concrete is hereby authorized to discharge stormwater from a facility located at Ready Mixed Concrete 302 Hicks Street Edenton, NC Chowan County to receiving waters designated as an unnamed tributary to Queen Anne Creek in the Chowan River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV of General Permit No. NCGI40000 as attached. This certificate of coverage shall become effective February 24, 1995. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day February 24, 1995. Signed P,y Colecn K Sullins A. Preston Howard, Jr., P.E., Director Division of Environmental Management By Authority of the Environmental Management Commission ssy7mw.P 'r91 199t f°93 F aa5i . •I /i c= tl a _ _ ' 4 - t b x 11 b � li /I I I of �� .I d6.0 . C 32 /Radio Tower CDJI I ��--' � `n ShCente�r IiW ss �,/ St e r.. { •"^` - , " �NOIV Temple " Beav HIII ?'�Vlde Oahe',' r • mo 1/ • �, -Unlprr Grove . 'I� \ Ch ;�•IIpS �_�� - ' • Ce Cell h J o O 43 t // to r • _ �� a5 } •, RovTdawi 17 �. ACF Y. p AO 5 / I / / - - / _ I Il • re I `- pUF ,y CAUA[M1. � e. IYD C,l'm \ I ° i' 3� /' .� � I \' . . U I Cem• I 1 .. e.