Loading...
HomeMy WebLinkAboutNCG140035_COMPLETE FILE - HISTORICAL_20081014PERMIT NO STORMWATER DIVISION CODING SHEET NCG PERMITS /v u& /,l0 035 DOC TYPE I ri HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ J L)D Y) o %y YYYYM M D D Michael 17. Easley, Governor William Ross, al Secretary '(n+,i L�J Iyr1vJt North Carolina Department of Environment and Natural Resources v Coleen H. Sullins, Director Division of Water Quality October 14, 2008 Mike Setzer, Division Manager 320 Market St. Sanford, NC 27330 Subject: Stormwater Compliance Inspection NPDES Permit No. NCG140035 Ready Mixed Concrete Co. Lee County Dear Mr. Setzer: On September 17, 2008), Vicki Webb of the Raleigh Regional Office conducted a stormwater compliance inspection of the subject facility. The facility is located at 320 Market Street in Sanford, NC. Your assistance was appreciated as it facilitated the inspection process. The following observations were made: Stormwater runoff from this site is discharged to the receiving waters designated as Little Buffalo Creek in the Cape Fear River Basin. The process water flows to the cement treatment pits. Water enters into the first pit and flows through.the series to filter out solids. The facility then recycles this water back into the plant operations. All components of the Stormwater Pollution Prevention Plan (SP3) were present including: detailed site map with labeled storm outfall, a list of potential contaminants, a spill and response plan, a narrative describing BMPs, and a contact list of whom to contact in an emergency. Employee training records were on -site. The facility inspects containment areas, storage tanks, and valves and piping on a monthly basis. This facility maintains good house keeping practices. The files are kept in a well organized fashioned. Such order eased the file review process. The overall condition of Ready Mixed Concrete Co. is compliant with Division standards. If you have any questions regarding the attached report or any of the findings, please contact Vicki Webb at: (919) 791-4256 (or email: vicki.webb n nemail.net Sincerely, Vicki Webb Environmental Specialist Cc: Central Files RRO files NYn`hCari olIna turrr n North Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Phone (919) 791-4200 Customer Service Intemet h2o.enestate.ne.us 1628 Mail Service Center Raleigh, NC 27699-1628 FAX (919) 571-4718 1-877-623-6748 An Equal Opportunity/Affirmative Action Employer— 50% Recycledl10% Post Consumer Paper Compliance Inspection Report Permit: NCG140035 Effective: 08/01/04 Expiration: 07/31/09 Owner: Ready Mixed Concrete SOC: Effective: Expiration: Facility: Ready Mixed Concrete -Sanford County: Lee 320 Market St Region: Raleigh Sanford NC 27330 Contact Person: Preston Satterfield Title: Phone: 919-776-8359 Directions to Facility: System Classifications: Primary ORC: Certification: Phone: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 09/1712008 try Tim : 08:50 AM Exit Time: 09:56 AM Primary Inspector: Vicki Webb /y (% ¢ O a' Phone: Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Ready Mix Concrete Stormwater/Wastewater Discharge COC Facility Status: ■ Compliant ❑ Not Compliant Question Areas: E Storm Water (See attachment summary) Page: 1 Permit: NCG140035 Owner - Facility: Ready Mixed Concrete Inspection Date: 09/17/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Page: 2 Permit: NCG140035 Owner - Facility: Ready Mixed Concrete Inspection Date: 09/17/2008 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? ■ ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ■ ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ■ ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ■ ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ■ ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ■ ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ■ ❑ ❑ ❑ # Does the Plan include a BMP summary? ■ ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? ■ ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? ■ ❑ ❑ ❑ # Does the facility provide and document Employee Training? ■ ❑ ❑ ❑ # Does the Plan include a list of Responsible Parly(s)? ■ ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ■ ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ■ ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ■ ❑ ❑ ❑ Comment: No spills. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ■ ❑ ❑ ❑ Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? WOOD # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ■ ❑ Comment: Permit and Qutfalls Yes No NA NE # Is a copy of the Permit and the Cenificate.of Coverage available at the site? ■ ❑ ❑ ❑ # Were all outfalls observed during the inspection? ■ ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ■ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ■ ❑ ❑ ❑ Comment: Page: 3 f.1rj�{ I is Guaranteed Strength February 18, 2005 READY MIXED CONCRETE COMPANY 3610 Bush Street, Raleigh, NC 27609 Telephone 919-790-1520 Fax 919-981-7475 NCDENR Mr. MICHAEL DARE 1628 MAIL SERVICE CENTER RALEIGH, NC 27699-1628 Dear Mr. Dare: P.O. Box 27326, Raleigh, NC 27611 In response to the Compliance Evaluation of NPDES Storm Water Permit, COC Number NCG140035 for Ready Mixed Concrete Co. Plant # 7, Sanford NC. Lee County. Item # 1. Disposal location of the liquid and solids from our detention pits. The pit system is designed to clean out solids with our wheel loader and store in a drying bin until material is dry, after drying it is used as back fill: The liquid is filtered with an industrial sand filter and reused washing down the trucks and as batch water in the production of concrete. We have on occasion used Sharpe trucking Co. to help control the freeboard in these pits. Sharpe told us that it dumped the water in a grassy field; I have included a copy of their bill for your review. Item # 4. The sediment pits in question were put in to catch solids from washing down the mixer trucks. A sand filter was added to help recycle the water in the production of concrete. The feasibility of protecting these pits from flooding of Little Buffalo Creek is impossible; during major storm events the whole section is flooded. The only recourse would be to move the whole facility. We have diverted stormwater away from these pits with curbing trying to maintain the system, but in a major storm event there is some flooding. We are open to any ideas on how to deal with this problem, other than moving the whole facility. I have also included invoices from Castrol Lubricants for the motor oil purchased at this facility during 2004. The mechanic stated that he though we were using about 300 gallons of motor oil a month. We only purchased 399 gallons for all of 2004, which equates to 33.25 gallons per month. Sincerely, <:5/=4Spence Regional Manager Member National Ready Mixed Concrete Association 02/18/2005 10:04 FAX 919 774 4040 READY HIM CONCRETE ¢J002/002 INVOICE No. N° 634 Sharpe Trucking Co., Inc. INVOICE DATE 1249 Frank Wicker Rd., Sanford, NC 27332 ICUSTOMM Phone/Fax: (919) 499-2646 1 ORDER NO. out • j V 1,1 :.4 waife, O'�r GRDCRGD On'3!,I f-P8L I DESr f--'Ir IIU^: I:!<r .:.I,:n _r„"100 o tj M En 1N{ N rn M M � r y� H t2 r+ 6 N O /. I O 0 � rl I n m ry� M W P. O ry Myy L F• I n 4- 0 H p 0— -Ca—st-rb-t 7 ORIGINAL INVOICE Please remit to: i Castro[ Heavy Duty Lubricants Inc PO BOX 409369 ATLANTA, GA 30384-9369 ,rel (410)5'14-5000, 1800)777-1466 Fax (410)780-8631 Sold To: READY MIXED CONCRETE Ship To: 320 MARKET STREET SANFORD NC 27330 Page: 1 Date 03/10/04 Customer: 347733 Brn/P1t: 2501 Related PO: Order Nbr: 51262726 S3 Invoice: 1380471 RI READY MIXED CONCRETE 320 MARKET STREET SANFORD NC 27330 Tax ID Tax Cer Salesperson: THOMAS E'WICKER f t ot qa CL�18io&T S. k` [�ui�a@•:' �t °".d 03/01/04 VRBL JAMIE 5 a s a a a a a a a a a as a a a a BULK a DRVER - ON TO FILL BULK TANK( I a 2.000 TECTION EXTRA 15W40-CASTRO 18510 B S 169.00 169.00 3.8300 647.27 03/01/0 BULK (GALLONS) Per GA 5 BULK 3.000 DUAL RANGE HV 66-CASTROL 42250 B S 225.00 225.00 3.7700 848.25 03/01/0 BULK (GALLONS) Per GA Vendor No. CA Site Invoice Date 3 -ia - o V Invoice Number o V �71 7l Net Amount Amount Div No GL Code Plant Coder Description DU,it� .2. 201 ct, +* 3 yl�;733 N. Terms: Net r Days D. r. r r. Rt: 7.000 104. ORIGINAL INVOICE —,co Castro[ ORIGINAL INVOICE Please remit to: _ 0 Castrol Heavy Duty Lubricants Inc PO BOX 409369 ATLANTA, GA 30364-9369 Tel (410)574-5000, (800)777-1466 Fax (410)780-8631 Sold To: READY MIXED CONCRETE Ship To: 320 MARKET STREET SANFORD NC 27330 Page: 1 Date 12/14/04 Customer: 347733 Brn/Plt: 2501 Related PO: Order Nbr: 51364078 S3 Invoice: 1534224 RI READY MIXED CONCRETE 320 MARKET STREET SANFORD NC 27330 Tax ID Tax Car Salesperson: THONAS E WICKER 12/02/04 VERBAL JAMIE 5 BULK Y Y4}; }i4#};i##;;4#LL4ii4;44;4}1; 411;1 ` DRIVER - OK TO FILL BULK TANKI ) ` 4;;;4;; 4};}#114444}44Y}Y}4YY4}}}4 4Y44L ` PER D BORA - DELIVERY ON 12/7/04 SURE ` 1.000 TECTION EXTRA 15W40-CASTROI 18510 B S 230.00 230.00 3.9800 12/02/0 BULK (GALLONS) Per GA Vendor No. Site Invoice Date _lf/ey Invoice Number is 3 yaa �L Net Amount Amount No" Code coder Description %9• f!8 7oi Aso a is o MS s Tetms: Net 30 Days Net Due Date: 01/13/05 64.08 915.40 ORIGINAL INVOICE ema 1 Y February 4, 2005 Mr. Larry Spence Ready Mixed Concrete - Sanford 3610 Bush St. Raleigh, NC 27609 Subject: Compliance Evaluation Inspection Ready Mixed Concrete - Sanford NPDES Stormwater Permit No. NCG140035 Lee County Dear Mr. Spence, Michael F. Easley, Governor William G. Ross, Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E., Director Division of Water Quality This writer, of the NC Division of Water Quality, conducted an inspection of the Ready Mixed Concrete - Sanford Plant on January 18, 2005. Mr. Steve Caulberg, Mr. Ray Jeffries and Mr. Jamie Godwin, represented the Ready Mixed Concrete - Sanford Plant during the inspection. The assistance of everyone was greatly appreciated. Findings during the inspection are as follows: 1) The collection trough, for process water associated with the recycle system, was filled to the top. A thick layer of ice had formed on the surface of the water in this trough. Mr. Caulberg stated that as soon as the weather warmed up he would have a septic -type hauling contractor pump this area out and any solids would be scooped up and placed in a spoils pile for future disposal. Please inform this Office of the disposal location for both the liquid and solids from this recycle system. The liquid disposal activity will likely require a NCDENR Pump and Haul Permit. 2) Mr. Godwin reported that new motor oil usage was approximately 300 gallons month. Because of this, the Analytical Monitoring Requirements for On -Site Vehicle Maintenance apply. (Applies to facilities using more than 55 gallons of new motor oil per month when averaged over the calendar year.) This requires that each stormwater discharge outfall (SDO) that discharges stormwater from areas of vehicle maintenance be sampled and results reported for pH, total suspended solids, oil and grease, new motor oil usage, total rainfall, event duration and total flow. (This would appear to apply to the "batch house" SDO only.) 3) In a response letter from you, to the NC Division of Water Quality, dated 12/12/2002, you indicated, "The sediment pit during a storm event can overflow and mix with stormwater." If this system is discharging, then you must comply with the monitoring requirements in your permit under the section, Process Wastewater Associated With Recycle Systems. This section requires that the recycle system discharge outfall be sampled and results reported for pH, total suspended solids, settleable solids, total rainfall, event duration and total flow. 4) North Carolina Administrative Code 15A NCAC 02H .0219, MINIMUM DESIGN REQUIREMENTS, specifies that treatment works and disposal systems (which would include the recycle system) be protected from a 100-year flood. Mr. Jeffries stated that, during severe storm events, water from the adjacent Little Buffalo Creek has flooded the process water collection trough area of the recycle system. This would indicate that this area is within the flood plain. Measures need to be taken to protect the collection trough, and any other portions of the recycle system affected, from floodwaters. Please inform this office of the steps to be taken to achieve this. 5) Significant gravel, sand and fines, from Plant operations, were noted leading to both Plant outfalls. These areas should be routinely cleaned to prevent the material from migrating to the creek. This procedure should be included in the Preventative Maintenance and Good Housekeeping Program portion of the Plant's Stormwater Pollution Prevention Plan. During this inspection, testing results were available for sampling that was performed at the "batch house' stormwater discharge outfall only. Analytical monitoring requirements also apply to the "Maple St." outfall. This includes sampling and reporting for pH, total suspended solids, total rainfall, event duration and total flow. All stormwater o ow aura(!y North Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Phone (919) 5714700 Customer Service Internet: h2o.encstate.nc.us 1628 Mail Service Center Raleigh, NC 27699-1628 FAX (919) 571-4718 1-877-623-6748 An Equal Opportunity/AKnna6ve Action Employer— 50%a Recycled/10%a Post Consumer Paper Mr. Spence Page 2 rr discharge outfalls have qualitative monitoring requirements for color, odor, clarity, floating solids, suspended solids, foam, oil sheen and other obvious indicators of stormwater pollution. As requested by Mr. Caulberg, I have attached a Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report form. Qualitative monitoring of outfalls is performed semi-annually, at the times specified in your Permit. 6) Mr. Caulberg stated that he believed the water used for the wetting of stockpiled materials was evaporating prior to leaving the property. If this system were to discharge, you would need to comply with the monitoring requirements in your permit under the section, Process Wastewater Associated with Raw Materials Stockpiles. This section requires that analytical monitoring of process wastewater associated with wetting of raw material stockpile discharges be performed for pH, total suspended solids, settleable solids, event duration and total flow. Should there be no runoff, you must submit an annual analytical monitoring report stating, "No discharge, therefore, no sampling required." 7) Past pH testing at your Plant has been performed by a Contract Laboratory. Because the holding time for pH samples is 15 minutes, this Office requests that you acquire a pH meter and perform all pH testing on -site. The meter must be calibrated prior to each use with a series of pH buffer solutions. (Note that pH paper is not acceptable.) Obviously, there is a training component in this requirement. Perhaps one person within the Ready Mixed Concrete organization could become proficient in the use of the meter and train all of those requiring this knowledge at the Ready Mixed locations with storm water permits. NC Division of Water Quality personnel may observe Ready Mixed Concrete personnel perform a calibration and test a sample during future inspections. Please provide to this Office in writing, the information requested in items 1 and 4 above, within 30 days of receipt of this letter. Please call me at (919) 571-4700 if you have any questions concerning the requested information or any other questions regarding this inspection. Sincerely, Michael Dare Environmental Technician Cc: EPA Central Files w 0 Stormwater Discharge Outfall (SDO) Qualitative Monitoring Report Permit No.: Facility Name: Countv: Inspector: Date of Inspection: or Certificate of Coverage No.: Phone No. By this signature, I certify that this report is accurate and complete to the best of my knowledge: (Signature of Permittee or Designee) 1. Outfall Description Outfall No. Structure (pipe, ditch, etc.) Receiving Stream: Describe the industrial activities that occur within the outfall drainage 2. Color Describe the color of the discharge using basic colors (red, brown, blue, etc.) and tint (light, medium, dark) as descriptors: 3. Odor Describe any distinct odors that the discharge may have (i.e., smells strongly of oil, weak chlorine odor, etc.) 4. Clarity Choose the number which best describes the clarity of the discharge where 1 is clear and 10 is very cloudy: 2 3 4 5 6 7 8 9 10 Page I 5 WU-242-101599 5. Floating Solids Choose the number which best describes the amount of floating solids in the stormwater discharge where 1 is no solids and 10 is the surface covered with floating solids: 1 2 3 4 5 6 7 8 9 10 6. Suspended Solids Choose the number which best describes the amount of suspended solids in the stormwater discharge where 1 is no solids and 10 is extremely muddy: 1 2 3 4 5 6 7 8 9 10 7. Foam Is there any foam in the stormwater discharge? Yes No 8. Oil Sheen Is there an oil sheen in the stormwater discharge? Yes No 9. Other Obvious Indicators of Stormwater Pollution List and describe Note: Low clarity, high solids, and/or the presence of foam or oil sheen may be indicative of pollutant exposure. These conditions may warrant further investigation. Page 2 SWU-242-101599 �- ATE, s � Ailun Ircli ...... - CERTIFICATE OF ANALYSIS - Attn: Mike Setzer Ready Mixed Concrete Co. P.O. Box 688 Sanford, NC 27330- ClientIt: S0930 cb / /G. \ �/J cL. Report Date: 24-Aug-0d, .� �- Reprinted Report Phone: (919)776-8359 ExL- FAX: (919) 774-4043 ATEL Lai) N: SAN0,1-01721 - COLLECTION INFORMATION - Date Received: E8/12/2004 Sample ID: Drain Dale Logged -la: 8/13/04 Collection Dale: 08/12/2004 Quote It: Collection Time: 2:20 PM Client PON: 1721 Collected By: Mike Stzei Client Project It: Matrix: Storm Water Sample Source: Swint Water Test Croup 'I'es( Method Result Units Analysis Date Analyst NVSN SS 160.2 22221 Residue, Nonfiltemble (Suspended) 55.0 utg/L 09/16/2004 MAJ PH -LAD 150.1 /9040 22211 pH, Lab 7.9 S.U. 08/12/2004 MAJ --- QC Related To Sample --- WSN QC Lab# QC Test ID Itsult (mils Anmmd - QC Calcula(iuus- -QC Calculations - Ln»'er Upper Code 01 Spike OCI Qe•2 Limit Limit 22211 SAN04-01721 U I'II-LA11 7.9 S.U. 11 0 ",61) 20 Report Approved By: Liu!of'Report North Carolina Cer(ilications: NCDWQ N332 / NCDEH 437742 Lab Nuurher S'dN04-017214'age I 936 N. HORNER BLVD. • SANFORD, NC 27330 PHONE 919-776-5999 • 1-800-522-2832 • FAX 919-774-7068 ATEL i4y�}Cry"haYi-y.✓f=Len i��^1w15! Aqua 'li,,h Con i .hour.. lnl Coburn lnr irs• hu Report Date: 06-A—uk_03., - CERTIFICATE OF ANALYSIS - Reprinted Report Attn: Mike Setzer Ready Mixed Concrete Co. 11.0. Box 688 SAnford, NC 27330- Client #: S0930 I CO Phone: (919) 776-8lExl: FAX: (919) 774-4043 359 I ATEL Lab #: SAN03-02105 �� r�r^•.l r`- I - COLLECTION INFORMATION Date Received: 7/23/2003 Sample ID: DRAIN =1 Dale Logged -In: 7/24/03 Collection Dale: 07/23/2003 Quote #: Collection 'Dime: 10:30 AM Collected By: MIKE SE,rzER Client PO#: 02105 Matrix: Source Water Client Project #: Sample Source: Source Water Test Group 'rest Method Result Units Analysis Date Analyst WS# PIi-LAB pi 1, Lab 150.1/9040 21372 6.4 S.U. 07/23/2003 RLC --- QC Related To Sample --- WSH QC Lab$ QC Test lD Result Units Amount - QC Caicuintions- - QCCalculations- Lower Upper Code Of Spike 1.6nit Limll QCI Qcz 21372 SAN03-02105 D 1111-1,AB 6.3 S.U. 0 2 %D 20 Report Approved By: End of Report North Carolina Certifications: NCDWQ 1032 / NCDEII #37742 lab Nnmher 3AN03-02105: rage I 936 N. HORNER BLVD. • SANFORD, NC 27330 PHONE 919-776-5999 • 1-800-522-2832 • FAX 919-774-7068 OF CERTIFIED MAIL RETURN RECEIPT REQUESTED Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources 12/8/2003 Alan W. Klimek, P.E. Director Division of Water Quality Preston Satterfield o I\ Ready Mixed Concrete PO Box 688 — Sanford NC 27330 cr SUBJECT: NOTICE OF VIOLATION AND REVOCATION FOR NON PAYMENT o PERMIT NUMBER NCG140035 Ready Mixed Concrete -Sanford Lee COUNTY Dear Permittee: Payment of the required annual administering and compliance monitoring fee of $80.00 for this year has not been received for the subject permit. This fee is required by Title 15 North Carolina Administrative Code 2H.0105, under the authority of North Carolina General Statutes 143-215.3(a)(1), (1 a) and (1 b). Because this fee was not fully paid within 30 days after being billed, this letter initiates action to revoke the subject permit, pursuant to 15 ncac 2H.0105(b) (2) (k) (4), and G.S. 143-215.1 (b) (3). Effective 60 days from receipt of this notice, subject permit is hereby revoked unless the required Annual Administering and Compliance Monitoring Fee is received within that time. Discharges without a permit are subject to the enforcement authority of the Division of Water Quality. Your payment should be sent to: N.C. Department of Environment and Natural Resources Division of Water Quality Budget Office 1617 Mail Service Center Raleigh, NC 27699-1617 If you are dissatisfied with this decision, you have the right to request an administrative hearing within Thirty (30) days following recipt of this notice, identifying the specific issues to be contended. This request must be in the form of a written petition conforming to Chapter 150E of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, Post Office Drawer 27447, Raleigh, North Carolina, 27611-7447. Unless such request for hearing is made or payments received, revocation shall be final and binding. If you have any questions, please contact: Mr. Ken Schuster, Raleigh Water Quality Regional Supervisor, (919) 571-4700. Sincerely, off` Alan W. Klimek, cc: Supevisor, Water Quality Permits and Engineering Unit - Raleigh Regional Office County Health Department 1617 Mail Service Center, Raleigh, NC 27699-1617 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled / 10% post -consumer paper READY MIXED CONCRETE COMPANY cr___ —1 ❑ xJ Guaranteed Strenqth August 15, 2003 3610 Bush Street, Raleigh, NC 27609 Telephone 919-790-1520 Fax 919-981-7475 NCDENR Paul B. Clark 1628 MAIL SERVICE CENTER RALEIGH, NC 27699-1628 Dear Mr. Clark: P.O. Box 27326, Raleigh, NC 27611 In response to your letter about NPDES permit NCG140035 Ready Mixed Concrete Co. Plant 7, Sanford, NC. Lee County. You ask that I respond to Item # 5 and #6. Item # 5: Number 5 is easy. I have included the new site plan in this letter for your review. The reason that the old site plan was still in our SWPP manual was we added the information to it that Mr. Nisely had requested. Item # 6: Our locations that are required to sample stormwater, test pH with pH test paper, during the storm event. Mike Setzer is so close to the lab that the lab has tested the pH for us. I will have Mike do his own pH test in the future, and the time concern will not be a problem in the future. We are looking at some systems to treat pH in our wash -pits. I will buy some pH monitors to check the accuracy of these systems, once these systems are up and operating. Sincerely,, Larry Spence Assets Manager Member National Ready Mixed Concrete Association Michael F. Easley, Governor ' O� F W ATF9QG William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources o Alan W. Klimek, P.E., Director Division of Water Quality September 4, 2003 Mr. Roger Kelley, County of Lee P.O. Box 1968 Tax Administrator Sanford, North Carolina 27331-1968 Subject: Tax Certification Ready Mixed Concrete - Sanford Process Wastewater Treatment System Certificate of Approval No. TCS-RH-160 Lee County Dear Mr. Kelley: Transmitted herewith are two (2) copies of Tax Certification TCS-RH-160. This certification is for the Ready Mixed Concrete - Sanford Facility (Plant #7) that is permitted under NPDES Stormwater General Permit NCG140000 - Certificate of Coverage NCG140035. Ready Mixed Concrete may use this Certification to obtain tax benefits in accordance with the appropriate North Carolina General Statutes. The attached Certification includes the water pollution abatement and associated equipment that should be used for tax exclusion purposes under North Carolina General Statute 105 — 275 (8). Please note that the Division of Water Quality has not attempted to confirm costs for the equipment. We have confirmed that the equipment was in place and operating properly during our inspection on July 29, 2003. If you have any questions regarding this matter, please contact Paul Clark, of my staff, at (919) 571- 4700, ext. 260. Attachment Raleigh Regional Office 1628 Mail Service Center, Raleigh, INC 27699-1628 Sincerely, Kennet e , .E. Regional Water Quality Supervisor Internet http://h2o.enr.state.nc.us/ Telephone (919) 571-4700 Fax (919) 571-4718 *A NCDENR DENR Customer Service Center An Equal Opportunity Action Employer Telephone 1 800 623-7748 50% recycled/10% post -consumer paper NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH, NORTH CAROLINA TAX CERTIFICATION (Franchise/Privilege; Amortization; Property) In accordance with the provisions of North Carolina General Statute 105-275(8), this document is to certify that: Ready Mixed Concrete - Sanford Lee County has been issued North Carolina Department of Environment and Natural Resources — Division of Water Quality General Permit No. NCG140000 — Certificate of Coverage No. NCG 140035 for the operation of the Ready Mixed Concrete — Sanford — Plant n7 that discharges stormwater to Little Buffalo Creek in the Cape Fear River Basin. The applicable wastewater treatment (filtration) system allows the recycle of process wastewater and prevents the discharge of process wastewater to North Carolina waters. The treatment system consists of the following: Pump Systems Industrial Filtration system (Model MOCK-FG-24) and associated equipment to serve the Ready Mixed Concrete Sanford —Plant #7 facility located in Lee County, North Carolina This treatment system is being operated in accordance with the North Carolina Department of Environment and Natural Resources — Division of Water Quality General Permit No. NCG140000 — Certificate of Coverage No. NCG140035. The Environmental Management Commission (EMC) and the Department of Environment and Natural Resources have found that the facility referred to above: a. has been constructed and placed into operation; b. complies with the requirements of the EMC; C. is being operated in accordance with the terms and conditions of the North Carolina Department of Environment and Natural Resources — Division of Water Quality General Permit No. NCG140000 — Certificate of Coverage No. NCG140035; and d. has as its primary, rather than incidental purpose, the reduction of pollution resulting from the operation of the facility. Tax Certification Ready Mixed Concrete - Sanford Page 2 Issued at Raleigh, North Carolina this 4`h day of September, 2003 By the direction of the North Carolina Environmental Management Commission and the North Carolina Department of Environment and Natural Resources. n Kenneth Schuster, P.E. Regional Water Quality Supervisor Raleigh Regional Office TCS-RH-160 OF N ATF9 Michael F. Easley, Governor o� pG William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources o < Alan W. Klimek, P.E., Director Division of Water Quality September 4, 2003 Mr. Larry Spence, Asset Manager Ready Mixed Concrete - Sanford P.O. Box 688 Sanford. NC 27330 Subject: Tax Certification Ready Mixed Concrete - Sanford Process Wastewater Treatment System Certificate of Approval No. TCS-RH-160 Lee County Dear Mr. Spence: Transmitted herewith are two (2) copies of Tax Certification TCS-RH-160. This certification is for the Ready Mixed Concrete - Sanford Facility (Plant #7) that is permitted under NPDES Stormwater General Permit NCG140000 - Certificate of Coverage NCG140035. Ready Mixed Concrete may use this Certification to obtain tax benefits in accordance with the appropriate North Carolina General Statutes. The attached Certification includes the water pollution abatement and associated equipment that should be used for tax exclusion purposes under North Carolina General Statute 105 — 275 (8). Please note that the Division of Water Quality has not attempted to confirm costs for the equipment. We have confirmed that the equipment was in place and operating properly during our inspection on July 29, 2003. If you have any questions regarding this matter, please contact Paul Clark, of my staff, at (919) 571- 4700. ext. 260. Attachment Raleigh Regional Office 1628 Mail Service Center, Raleigh, INC 27699-1628 Sincerely, i Z�Re — 4/�4hc4hst_e��P. nnE. Regional Water Quality Supervisor Internet http://h2o.enr.state.nc.us/ Telephone (919)571-4700 Fax (919)571-4718 VLIW �jWA NCDENR DENR Customer Service Center Telephone 1 800 623-7748 An Equal Opportunity Action Employer 50% recycled/10% post -consumer paper t i � Q Michael F. Easley, Governor ? �WATegO William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources o Y Alan W. Klimek, P.E., Director Division of Water Quality September 4, 2003 Mr. Larry Spence, Asset Manager Ready Mixed Concrete - Sanford P.O. Box 688 Sanford, NC 27330 Subject: Tax Certification Ready Mixed Concrete - Sanford Process Wastewater Treatment System Certificate of Approval No. TCS-RH-160 Lee County Dear Mr. Spence: Transmitted herewith are two (2) copies of Tax Certification TCS-RH-160. This certification is for the Ready Mixed Concrete - Sanford Facility (Plant #7) that is permitted under NPDES Stormwater General Permit NCG140000 - Certificate of Coverage NCG140035. Ready Mixed Concrete may use this Certification to obtain tax benefits in accordance with the appropriate North Carolina General Statutes. The attached Certification includes the water pollution abatement and associated equipment that should be used for tax exclusion purposes under North Carolina General Statute 105 — 275 (8). Please note that the Division of Water Quality has not attempted to confirm costs for the equipment. We have confirmed that the equipment was in place and operating properly during our inspection on July 29, 2003. If you have any questions regarding this matter, please contact Paul Clark, of my staff, at (919) 571- 4700. ext. 260. Attachment Raleigh Regional Office 1628 Mail Service Center, Raleigh, NC 27699-1628 Sincerely, �� I Z�Ken eth ch ste , P.E. Regional Water Quality Supervisor Internet http://h2o.enr.state.nc.us/ Telephone (919)571-4700 Fax (919)571-4718 R7La�A NC_DEP.R DENR Customer Service Center Telephone 1 800 623-7748 An Equal Opportunity Action Employer 50% recycled/10% post -consumer paper NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES RALEIGH, NORTH CAROLINA TAX CERTIFICATION (Franchise/Privilege; Amortization; Property) In accordance with the provisions of North Carolina General Statute 105-275(8), this document is to certify that: Ready Mixed Concrete - Sanford Lee County has been issued North Carolina Department of Environment and Natural Resources — Division of Water Quality General Permit No. NCG140000 — Certificate of Coverage No. NCG140035 for the operation of the Ready Mixed Concrete — Sanford — Plant 47 that discharges stormwater to Little Buffalo Creek in the Cape Fear River Basin. The applicable wastewater treatment (filtration) system allows the recycle of process wastewater and prevents the discharge of process wastewater to North Carolina waters. The treatment system consists of the following: Pump Systems Industrial Filtration system (Model MOCK-FG-24) and associated equipment to serve the Ready Mixed Concrete Sanford — Plant #7 facility located in Lee County, North Carolina. This treatment system is being operated in accordance with the North Carolina Department of Environment and Natural Resources — Division of Water Quality General Permit No. NCG140000 — Certificate of Coverage No. NCG140035. The Environmental Management Commission (EMC) and the Department of Environment and Natural Resources have found that the facility referred to above: a. has been constructed and placed into operation; b. complies with the requirements of the EMC; C. is being operated in accordance with the terms and conditions of the North Carolina Department of Environment and Natural Resources — Division of Water Quality General Pennit No. NCG140000 — Certificate of Coverage No. NCG140035; and d. has as its primary, rather than incidental purpose, the reduction of pollution resulting from the operation of the facility. Tax Certification Ready Mixed Concrete - Sanford Page 2 Issued at Raleigh, North Carolina this 4`h day of September, 2003 By the direction of the North Carolina Environmental Management Commission and the North Carolina Department of Environment and Natural Resources. Kenneth Schuster, P.E. Regional Water Quality Supervisor Raleigh Regional Office TCS-RH-160 Michael F. Easley, Governor OF W A T�9 o� qG William G. Ross Jr., Secretary y North Carolina Department of Environment and Natural Resources o < Alan W. Klimek, P.E., Director Division of Water Quality September 4, 2003 Mr. Roger Kelley, County of Lee P.O. Box 1968 Tax Administrator Sanford, North Carolina 27331-1968 Subject: Tax Certification Ready Mixed Concrete - Sanford Process Wastewater Treatment System Certificate of Approval No. TCS-RH-16C Lee County Dear Mr. Kelley: Transmitted herewith are two (2) copies of Tax Certification TCS-RH-160. This certification is for the Ready Mixed Concrete - Sanford Facility (Plant #7) that is permitted under NPDES Stormwater General Permit NCG140000 - Certificate of Coverage NCG140035. Ready Mixed Concrete may use this Certification to obtain tax benefits in accordance with the appropriate North Carolina General Statutes. The attached Certification includes the water pollution abatement and associated equipment that should be used for tax exclusion purposes under North Carolina General Statute 105 — 275 (8). Please note that the Division of Water Quality has not attempted to confirm costs for the equipment. We have confirmed that the equipment was in place and operating properly during our inspection on July 29, 2003. If you have any questions regarding this matter, please contact Paul Clark. of my staff, at (919) 571- 4700 ext.260. Attachment Raleigh Regional Office 1628 Mail Service Center, Raleigh, NC 27699-1628 Sincerely, Kennet ch e . .E. Regional Water Quality Supervisor Internet http://h2o.enr.state.nc.us/ Telephone (919) 571-4700 Fax (919)571-4718 ASA NCDENR DENR Customer Service Center An Equal Opportunity Action Employer Telephone 1 800 623-7748 50% recycled/10% post -consumer paper Comments on Review of Sanford Ready Mixed Request for Tax Exemption, 8/6/03 A properly engineered system would take into account whether the facility is located on a 100 year flood plain. If it is in the flood plain, we will want to discuss the situation with the Stormwater Group downtown. A check of maps for this location shows the recycle structure to be very near or slightly inside the flood plain, but too close for us to call from the maps. The 100 year elevation is shown to be 357' above sea level. The elevation of the structure maybe between 355 and 358'. Steve Mitchell recommends that we ask Ready Mixed to establish accurately the elevation of the recycle pits at the point closest to the stream, and have them determine whether or not they are in the flood plain. If they are in the flood plain, might they erect an outside wall to shield the pit from infiltration during a big rain? Myrl City of Sanford �P�"IFFOHD 370143 STREET TR�E E r STROUo �F9 339 340 34 MC Glt'_ STREET STREET, ®r 1. (D? PLEE Ty 1343 ZONE AE TALLEY 3 15�5 _�L-�- 1J=111S E AE FN-1-51 SYCAMORE STREET � }qF M 5 71 � 1� •� I,jja • �� art �� � 4 .{i }� �.J�- lV��'V �}`fi T„ ,i'. I /J /..vi \ .�\r y/ :I A/- \. �`� •'kdra r t"�. t 45 r � J4rz��� .,� ti� 1 b.. �.. 1 � �+ �� ��: a e• f r y*` " a ck �r 'k. arl «r faa�\. -•,.�`. w \A �• ,^r. t ,. rx+.k•4 r��a4 r A/! Fy � :f �•.L1 �' ✓+ L �, w`.v . 36 Ski ewJ fe'>, r>'` �� >r i 1 M �/ yF yi '1✓S�r t i 4 n ate, 1 • .. �/' � ...Po ,Y � ,L i �x: v 'C, -' � C � M 1 vM1 t � V � � P" `"�' £i Nr �',"�1 {' '£} ' r k �+ ✓Jb"�t „ r" xx � r�• r e wti � � � ., r�l tinby, av �.� \ � �.A � v� ... ,.� �r rcL.."- '� R t � yl r n .r". rr✓ � � ��{ 'C £ £" t,19� '°' " if?. 5 � N� � � h "' o- �x�e° Ah i . 1�,� � � � . > �'s �"e ✓. ��, is � t � '! yam:., x ,1 v i �''�' .✓�A, � �'?k '� ��, M1Ye a tl �. � h,+ '",+ 9 '' . / . .+" Y ""� ��4 �-. � � a �tiw . r'�'-t " r Kv1 � 7 •. +' � f +f `tr✓a '!fi � a •• i e \`���=j �� � S v'L., a O, S`'yA i '. � yti r h .. [j r. / p •` S i �� * t w 7 ,C,� �i,i vr�i� �k r SxAr• k,"y rf'" �' S �1fi rrrf v� ��fi / �y,r , 3 � � �. y . •be � 4 C R �" * r f~ ,+ R: �'i r h t r '� rrt\G.4 `R � �k � , � � r • `�.^+y � Y A,r 4'.'�'t"'k''rf d ^ -f-._ , i � 1... 1 �:�._r l � q� x' _ 4'V'yyA v� � K fi .A O��tl r ♦t-` r'`.. ` k.�'f � f7� • • � \4 ,.z rs, � x .tiS b r \ ..Fn, n ✓'r aK , v A �t vpp r �' ,/ �� A S S y h F Q� h✓ • o �y ,r �{� � 3:� � o-,�x �¢ �r � '��,��X p�j/�1?F r4v� / ,hey S S .'r ' r `� -i • ` 'A.w r 5 '� ,�,i}S t±,'�`f�- • • � i n4a r '{hh *'\A t' ✓ G} � 2 2� ♦ r 1s'vv J r � • 1' / r 5 �..' AJ .��, .,�V vy * • " f�;' �.+ '.�`1 5 tk 'i x t •q �.A ..; ., �`•J ' , � � � b" zh � I•t S �� r � f�. �Sr Yr ,� � w .�� J,� .� 1'.. a$ 1 7�� +£.\� 7.._d kY Sir p vry t 5 � ♦ _ +•'fit ��. hF /�" �� �� t r o:-t � • v r 1 •♦ „ ±, i�� I m M r`r y.u."y ».,. `: r.-......^ ,A '�'° T�ar^�F ��:. `'"....�• tQ�f. ..`:.� v'.`Wr _ opyrignt (L,) iaar, Mapiecn, inc -- ana�.. �; t¢`..?fy, .:. y a. '�. �r. a r7 a d ,r•:kd#� I 5'° x�r:' n�.-' I ^b'i c .. / I a ° a `'' � A . p•�, rc*, y"'' 4 `-' U t za wi"e,•��..'�tr T _ ns°.: a�' r�•� ° ` I � s F I •ry I d �..*�, � ,�` ifU°�'st � bnt� °�la f '.� i � �°f._,�.�'9 �" 2.,,s` ,�'��rT''�—' _ � _. �"..it. � it � �., � � -� � °�' �°�' � �9'sym t �Y .��a' _ r�„ r-7 ems. .�..r.-+,--. _ �*.��.; •y �r�n� x'.� ry ^ >. a. a" i.�+ �:` �"._ s'-,a=8 a'�. � � ?, :� �a 3- Y'" �S, -'- .. .:_ r= �` ��•hr a.°�Ti s� s�gaai�r°a. � 4 ' �.....-..., r „a a m - ��"�•� � 'I�� a �° t ..° n � ' ,,+��� >L' r�j1P e. t� �at`§.nnav a°.sa`'� ,+ � p1�y `S,_' 1 c� a^•;�'`��i. �zi �gia a�A � rn4.�-rr_ 9p���T � �i'., � I . i a y xp i_ ti s a 2(9 ))) � I. }P' �� � 1 .• 'r' saa a t i' 1 °a. ,;, .aa� �' •.- >Ftt�" ,. �. ;r' x°- �yu ��p� /s _t .'xda � ten.: I ; 2 �,� a, s '.+" z"F .x^s.� s 9 u a r• r to n, ❑ �' a- n s� .. � `'e�; t i - z/ y -� (( z rs ta' ro•'. I a v f �i.. a �'�.°� u, 7iYa4a na a,..a a a. sy Pd`4, Ike . sn �i fF eF d a5 :� � va yu .-I° T '- -j'jS+aF m _ n I;`�' 9 Y '�A� � 1, 4 -v a7 i •y Y,y�(� ° 1 °•` x 31 �� £'I'a ' � I -.'-'.'g.�.'vc �n r —� s�, 'ae ' - nv4�. `�J - ', -na � ;'r :+t `str F °a , .r i °a a- .�•` � u � b -p.a , y _. r i . Q 1°d r 'rs, y s. a: g x ,�_--N` r � ' 2 a :. r a-� rt , ,2,%• r� � �w r � �_��_- 'f �EII `c . n ;� .. •R- 'fi',ar�n I -a 1�-= a x :a._.. ' r. «' �. �II � sp �I �.� vl �a.A•i I �yt £° �^a �` e2. a�5 � �F2 fi? � °tn,i i�� t frt ❑ d `r Eva :'�a ,s.°�=. i a 'c' h,g•. ..�',yr � a. � . p� I �!'{ __ n �`�'%� 4° '�. 6 l w ti 4 ,fp,,, '? as P. 2 as,Pj.� ,. n _ i t xr- , Ct _ •. °� mow:. �.��x5� � � � .� � d Fnv�o P •tag .-t:`} .�' I �Edr a R j r r �. yr �"� � �� i s�.� n`• - 7f = Yr e� � � 1° � a 0;.: � fit. a i w� S,� nki, i" � aao`•+, 9 ;,,.d•�''PiF°ss .'C� y� an � �t u 14 Imo`¢ a` ° J 2'i 3Ak -�7 � F �4 •(-�y.� ) {�at :°�.O y ' YyJ n- � i {a-{'lyy }`y �F � t 'Ce a -,s5e a'` a ' ' 7 l ._: -u�a Fa' .,•a to e' I. z'x. "tt„a�•r. 'ra ^- a C`4,yax. z�t.'� I I O�� i tip ye` °r �'4. � &�, •", zya Y 'tsm,='r '�` �{: r x-n td_;. - � 1�fi�t y '"',a4`n PH � r I i I I I r n::l ° .s,,,xl •Aa: Ct L y � a -� d .. .c 1. r n '% i u � 3• '�'�rG�'e� :��. -�� � _,}`,� ' I ¢ I ��� � �'.J��a,� ��t7+y�,� �14 .b� 7��',•8s9 � 4 y--�'t yy_'• i I -�^'i ��� ° o. a ' .. - I� �r�._ j. � f x � ° !�� f •� `Jr a 'l* : �'F ;� al � °°,a a s nor 1 '' ;Rxfrs, tY•e�C� �sv�.... i , r-. } �.: i, ._�-t_ - ��( R t !�. °.. i'n A- " ^``.e`s e� la � .� <al t � 4 «.tu.-,• . , G � a-�-, ` 'r� `'� � I'��i- sl b4,,, r¢' a a'ti. 4 . 5 �+ • 3 .. a s�v h �I� .,,.� ;,� 1 la a t. "`�L��° .., 3. �I�-°l Michael --. Easlev. Governor G[, Ud' William G. Ross Jr.. Secretary r North Carolina Department of Environment and Natural Resources o Alan W. Klimek. F.E.. Director Division of `Plater Quality August 5, 2003 Mr. Larry Spence Ready Mixed Concrete - Sanford 3610 Bush Street Raleigh. NC 27609 Subject: Compliance Evaivation Inspection Ready Mixed Concrete — Sanford NPDES Stermwater Permit NCG140035 Lee County Dear Mr. Spence: On July 29. 2003. a Compliance Evaluation Inspection was conducted by the Division of Water Quaiity (DWQ) Raleigh Regional Office staff at Ready Mixed Concrete - Sanford Plant Y7 . The ccoperatign cf Mr. Mike Setzer was arestly appreciated As a result cf the inspection. the following comments ancicr recommendations were developed: General Permit No. NCG140000 — Cerificate of Coverage No. NCG1A003H became effenv= August 1. 1999 and will exojre July 31. 2004. _. The pfgce SS Wastewater recycling area Is completeiv surrcu'nced by coy^c,ete c-ir-ns (aDceaf is have been reinforced in some spots since Myri Niseiy's October 2002 site visit) that prevent stormwater from flowing into this area. All prccess wastewater (primahly ceneroted from the rinsing and washing of concrete truck) flows first into one. and then the second. of cYvo concrete -reucns. Process wastewater is then pumped through a fllter into o 301001 gallon i'onK one Then a HH, cailci,- tank, Where the water Is reused There Is no gischarce of process '.vasievvatef ;i C,T, ;.^iIS SYSicm. Examination of the creek (that is less than 10 feet from the two concrete trouans) apoearec tc indicate that the stream water level may rise dangerously close to the two concrete trouens during heavy rain events. Mike Setzer said that he has never known that the stream has ovencoeed the concrete troughs. 4. Mike Setzer demonstrated the backwash capability of the water filtration pump. It properiy discharged backwash water into the first of the two concrete troughs. The Ready Mixed Concrete Facility manual was reviewed for records of spills. BMPs, housekeeping, qualitative and quantitative monitoring, training, etc. The manual appeared complete, except that an updated site map (that was referenced in your December 12, 2002 letter) needs to be included in the manual. DWQ requests that a copy of this revised site map be sent to our office. Raleigh Regional Office 1628 Mail Service Center, Raleigh, NC 27699-1628 Internet http:/ih2o.cnr.state.nc.us/ Telephone (919) 571-4700 Fax (919.)571-4718 DENR Customer Service Center An Equal Opportunity Action Employer Telephone 1 800 623-7748 50% rerycled/10% post -consumer paper Mr. Larry Spence Page 2 August 5,2003 6. Mike Setzer states that after samples are collected, they are stored and chilled in a cooler and then transported to the laboratory. Mike Setzer stated that holding times for samples are met because the laboratory is only five miles from the facility. Because pH sample holding time is only 15 minutes, DWQ recommends that a pH meter be made available for on site use. Ready Mixed Concrete could purchase one pH meter to be used at several of its facilities. Please respond to item nos. 5 and 6 in writing by September 5, 2003. If you have any questions concerning this evaluation summary, please contact me at 571-4700 x 266. Thank you. Sincerely, D J l•, / Paul B. Clark Environmental Engineer cc: Central Files EPA United States Environmental Protection AgenZj Form Approved. EPA Washington, D.C. 20460 OMB No. 2040-0057 Water Compliance Inspection Report Approval expires8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yr/mo/day Inspection Type Inspector Fac Type 1 1„I 2 151 3I NCG140035 11 121 03/07/29 I17 18I„1 19 C1 20Li LJ LJ l-� U Remarks 211111111111111111111111111111111111111111111111161 Inspection Work Days Facility Self -Monitoring Evaluation Rating 31 CA ---------- —------- ----- Reserved ---- ------------------ 67 1 169 70 J 11 71 Lj 72 1L„ 1 73 1 1 174 75I I I I 11 80 IJ I I I Section 3: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 09:30 AM 03/07/29 99/08/01 Ready Mixed Concrete -Sanford Exit Time/Date Permit Expiration Date 320 Market Sc Sanford NC 27330 11:00 AM 03/07/29 04/07/31, Name(s) of Onsite Representative(s)/Titles(syPhone and Fax Number(s) Other Facility Data Larry Spence//919-790-1520/ Mike Setzer//919-776-8359/ Name, Address of Responsible Official/Title/Phone and Fax Number Contacted Preston Satterfield,PO Box 688 Sanford NC 27330//919-776-8359/ No Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Permit Operations & Maintenance Records/Reports Self -Monitoring Program Facility Site Review Effluent/Receiving Waters Storm Water Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) Name(s) and Signature(s) of Inspector(s) Agency/Office/Phone and Fax Numbers Date Paul Clark PRO WQ//919-571-4700/919-571-4718 Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. �iT %t r7 +.4�a{ � g4v'xr1l� `��i J,a'v"?�lurr'.v+pN�`y Aq ue 7i•, h I: rmi rn..... Ld Lahnra forira, L¢. Report Date�g - CERTIFICATE OF ANALYSIS - ""J Attn: PRESTON SATTERFIELD = READY MIXED CONCRETE CO T e li 320 MARKET ST SANFORD, NC 27330- 4 ' Phone: Client #: S0930 c (919) 776-8359 - Ext.- tr PAX: (919) 774-40,131 ATEL Lab #: SAN02-02454 T-- COLLECTION INFORMATION - Date Received: 7/26/2002 Sample ID: Drain Date Logged -In: 7/30/02 Collection Date: 07/26/2002 Quote #: Collection Tinie: 1:40 I'M Collected By: M. Selzer Client I'O#: 2454 Matrix: Other/Undefine Client Project#: 2454 Sample Source: Other Test Croup Test Method Result Units Analysis Date Analyst WS# SS 160.2 19776 Residue, Nonfiltei able (Suspended ) 7.8 mg/L 07/31/2002 KA13 PI I -LAB 150.1 /90+10 19775 pl 1, Lab 6.7 S.U. 07/26/2002 KAB --- QC Related To Sample --- WSH QC Lab# QC Test ID Itesuk Unils Amount - QC Calculations- - QC Calculations- Luker Upper Code OfSpike QCI QC2 _ Limit Limit 19775 SAN02-02454 D I'll -LAIC 6.7 S.U. fl %O ---- — -- -- 20 Report Approved By: /Axi/� /' 8nrl of Repot North Carolina Ceilifications: NCDWQ #332 / NCDEI-I #37742 Lab Nunlher.SNN02-0245d:Pagc I 936 N. HORNER BLVD. • SANFORD, NC 27330 PHONE 919-776-5999 • 1-800-522-2832 - FAX 919-774-7068 READY MIXED CONCRETE COMPANY l tgllp Guaranteed December 12, 2002 3610 Bush Street, Raleigh, NC 27609 Telephone 919-790-1520 Fax 919-981-7475 �Ia npe MR. KENNETH SCHUSTER, P.E. 1628 MAIL SERVICE CENTER RALEIGH, NC 27699-1628 Dear Mr. Schuster: P.O. Box 27326, Raleigh, NC 27611 In response to the Notice of Violation of NPDES Storm Water Permit COC Number NCG140035 Ready Mixed Concrete Co. Plant 7, Sanford, NC., Lee County. The first question in the letter of notice of violation references the design calculations to show that the present recycle configuration can control the stormwater and process water in accordance with our permit? This structure is only for process water, stormwater is diverted away from these concrete sediment pits by concrete curbing. This is why Mike Setzer said we could control the process water by recycling and the use of a permitted pump and haul company to help haul off water if we were at full capacity. The second statement noted that the pH of 11.45 was sampled out of the recycle tank with a note about pH higher than 10 being caustic. We are very aware of the dangers of high pH and even give customers MSDS sheets for our product, but this is not an a violation of our permit all concrete wash pits have high pH. We are trying to recycle all of this water to ensure no high pH water leaves our property. The third question asked about runoff on the Maple street side of the plant, that runoff needed to be tested and identified on the plant site map. I have included page 41 out of our stormwater plan Sec 2 Item D., it list the outfalls and the GPS coordinates and also the body of water that these outfalls drain to. The only run-off at this point is sheet flow. was not aware of the 30' vegetation rule for sheet flow. We will sample this discharge point from now on. The fourth Statement was about a zoomed in USGS-type map. Our plan includes a USGS map of the site. We have a narrative in our plan that provides the information you have asked for. I have tried to blow up a USGS map to the scale you have asked for and the information that you asked for is still not shown. I have included a copy for your review. The last statement requested that we show the areas being served by each discharge point on our site plan. This is also included in our S WPPP plan as part of the map section of the Member National Ready Mixed Concrete Association pR� READY MIXED CONCRETE COMPANY ® o; e 3610 Bush Street, Raleigh, NC 27609 P.O. Box 27326, Raleigh, NC 27611 �7 A)I Telephone 919-790-1520 r Fax 919 981 7475 Guaranteed Strength plan, yet since it is not on the actual sit map I will have Mid Atlantic Associates draw a new site map and include this information in it, when completed I will send you a copy. I have also included the section describing the run off square footage computation for your review that is already in our plan After reading Myrl Nisely letter of Notice of Violation, I cannot see what was in violation. All the info that you are requesting is already in our plan. I will forward a copy of the new site plan when it is completed. Sincerely, arty Spence Assets Manager Member National Ready Mixed Concrete Association 12/12/2002 07:46 919-774-4043 READY MIXED SANFORD PAGE 02 TABLE 2.1 VOLUMES pOTENTIAL;RUNOFE N.CR3004 OB NO MAA 95 . READY MIX TDC MID ATLAN ASSOCIATES COEFFICIENT : RUfVOFF STORM EVENT RAINFALL SURFACE .VOLUME, AREA, ftZ OF RUNOFF gal. RATE 0.91 5g,060 104,100 1 in124 hr 1 in124 hr 0.91 324 810 10 yr storm 5.5 in124 hr 104,100 0.91 383,870 6.5 in/ 24 hr 104,100 25 yr storm in Modified Rational Method 'Runoff coefficient for use ftz = square feet in inch hr = hour * Modified Rational Method Q = CiA where Q = total flow, cf = rainfall, ft i Z A = surface area, ft C = runoff coefficient 1 cf = 7.481 gallons Page t 2 'SITE ASSESSMENT A. SITE MAP ( Drawings 1.1 ) B. USGS MAP ( Drawings 2.1 ) ' Outfall 7.1 Drains into Little Buffalo creek that flows to the Deep River C. Significant Spills and Leaks- (Form 1.0) File (Appendix A.) ' There have been no significant spills or leaks at this location in the past three years.( 01-01-02) D. Non -Storrs Water discharges Non -Storm Water discharges were not observed at this plant location April 4, 2002. Non -Storm Water Discharge Certification ( Form 'File (Appendix A.) Outfall # 7.2 may contain Non-stormwater during a storm event. E. Outfall Narrative: Outfall # 7.1 N 35' 28.765 & W 79' 10,486 Outfall Narrative: Outfall # 7.2 N 35' 28.721 & W 79' 10.452 Outfall # 7.1 is located southwest of the plant at the drive way entrance this is more of's�G sheet flow off our property. Possible pollutants could be fuel, oil, from the mixer trucks and fines from sand and stone stockpiles. Q�trnJ"� Outfall # 7.2 Is located behind the truck wash down/wash out sediment pit north of the plant office. The sediment pit during a storm event can overflow and mix with stormwater. Possible pollutants could be fuel, oil, from our mixer trucks, cement/flyash fines from the wash pit and truck washing cleaners. Through our good housekeeping program these pollutants should be controlled. SWPPRMCC 1 Is V , V-:" "I nju Son, ny- — 0, V4"x Send To Printer Back To TerraServer 11 x 17 Print Size Image courtesy of the U.S. Geological Survey © 2002 Microsoft Corporation. All rights reserved. Terms of Use a Michael F. Easley, Governor d % William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality CERTIFIED MAIL RETURN RECEIPT REQUESTED Preston Satterfield Ready Mixed Concrete PO Box 688 Sanford NC 27330 12/13/2002 SUBJECT: NOTICE OF VIOLATION AND REVOCATION FOR NON PAYMENT PERMIT NUMBER NCG140035 Ready Mixed Concrete -Sanford Lee COUNTY Dear Permittee: Payment of the required annual administering and compliance monitoring fee of $80.00 for this year has not been received for the subject permit. This fee is required by Title 15 North Carolina Administrative Code 2H.0105, under the authority of North Carolina General Statutes 143-215.3(a)(1), (1a) and Itb). Because this fee was not fully paid within 30 days after being billed, this letter initiates action to revoke the subject permit, pursuant to 15 ncac 2H.0105(b) (2) (k) (4), and G.S. 143-215.1 (b) (3). Effective 60 days from receipt of this notice, subject permit is hereby revoked unless the required Annual Administering and Compliance Monitoring Fee is received within that time. Discharges without a permit are subject to the enforcement authority of the Division of Water Quality. Your payment should be sent to: N.C. Department of Environment and Natural Resources Division of Water Quality Budget Office 1617 Mail Service Center Raleigh, NC 27699-1617 If you are dissatisfied with this decision, you have the right to request an administrative hearing within Thirty (30) days following recipt of this notice, identifying the specific issues to be contended. This request must be in the form of a written petition conforming to Chapter 150E of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, Post Office Drawer 27447, Raleigh, North Carolina, 27611-7447. Unless such request for hearing is made or payments received, revocation shall be final and binding. If you have any questions, please contact: Mr. Ken Schuster, Raleigh Water Quality Regional Supervisor, (919) 571-4700. Sincerely, Alan W. Klimek, P.E. cc: Supevisor, Water Quality Permits and Engineering Unit Raleigh Regional Office County Health Department P.O. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919.733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled / 10% post -consumer paper READY MIXED CONCRETE COMPANY 320 Market Street, Sanford, NC 27330 Telephone 919-776.8359 Fax 919-774-4043 Guaranteed Strength February 18, 2002 Mr. Joe Albiston NCDEiNR 1628 Mail Service Center Raleigh, NC 27699-1629 Re: Notice of Violation Permit NCG 1400035 Dear Mr. Albiston: fJ 1=-il <;1 r P.O. Box 688, Sanford, NC 27330 Please allow us to respond to your letter about our Sanford plant. As you observed we have installed a water recycling system at our facility. All the water that we produce is 100% recycled. When you were at our plant you observed water seeping from a joint that was cut in the curb. This has been repaired. Again all the water that we produce is contained on our yard. In retercnce to the bulk storage tank at our shop. This is a 330-gallon waste oil tank. On February 12, 2002 you stated that 660-gallon tanks and above had to be contained. We have placed a dike wound this tank just to be on the safe side. As you can see we have and will continue to comply with all regulations. If you have :any questions, please feel free to call me. Sincerely, /� -v 3 Mike Setzer Ready Mixed Concrete Company Member National Ready Mixed Concrete Association State of North Carolina Department of Environment and Natural Resources Raleigh Regional Office �s Michael F. Easley, Governor NC®ENR William G. Ross, Jr., Secretary NORTH CAROUNA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES CERTIFIED MAIL DIVISION OF WATER QUALITY RETURN RECEIPT REQUESTED January 31, 2002 MR. MIKE SETZER READY MIXED CONCRETE - SANFORD P O BOX 688 SANFORD, NC 27330 Subject: Notice of Violation Permit NCG 1400035 Sanford, NC Lee County Dear Mr. Stephens: On December 12, 2001 Mr. Joe Albiston of the Raleigh Regional office of Division of Water Quality met with Ray Jefferies to conduct a stormwater inspection of Ready Mixed Concrete in Sanford. Upon inspection of the storage area for chemicals it was observed that secondary containment for this area was not in place. According to Certificate of Coverage NCG140035 Part II Section A 2(b) "A schedule to provide secondary containment for bulk storage of liquid materials, storage of Section 313 of Title III of the Superfund Amendments and Reauthorization Act (SARA) water priority chemicals, or storage of hazardous substances to prevent leaks and spills from contaminating stormwater runoff." According to Certificate of Coverage NCG140035 Part III Section A I "The Stormwater Pollution Prevention Plan shall be developed and implemented within 12 months of the effective date of the initial certificate of coverage issued pursuant to this general permit and updated thereafter on an annual basis." 1) Please submit above schedule and information on implementation. Runoff from the washing of the concrete trucks was not running into the containment pond but running off site. According to Certificate of Coverage NCG1400035 the Daily Maximum Limit for Total Suspended Solids is 30 mg/L, Settleable Solids is 5 mVL and pH is a range of 6-9. Please respond in writing to Mr. Joe Albiston of this office within 10 working days of receipt of this notification. Sincerely, Kenneth Schuster, P.E. Regional Supervisor cc: Central Files Lee County Health Dept. 1628 Mail Service Center, Raleigh, NC 27699-1628 Telephone (919)571-4700 FAX (919)571-0718 An Equal Opportunity Affirmative Action Employer 50% recycled110% post -consumer paper State'of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Kerr T. Stevens, Director PRESTON SATTERFIELD READY MIXED CONCRETE-SANFORD P.O. BOX 688 SANFORD, NC 27330 Dear Permittee: NCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES July 26, 1999 Subject: Reissue - NPDES Stormwater Permit Ready Mixed Concrete-sanford COC Number NCG140035 Lee County In response to your renewal application for continued coverage under general permit NCG 140000, the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983. The following information is included with your permit package: * A copy of general stormwater permit NCO140000 * A Stormwater Pollution Prevention Plan (SPPP) Certification Form. Completion of this form is required to certify that you have developed and implemented the SPPP as per the conditions of the permit. This form must be completed and returned to the Division within 30 days of receipt of this letter. DO NOT SEND the SPPP with the signed form. * Five copies of the Analytical Monitoring form and five copies of the Qualitative Monitoring form A copy of a Technical Bulletin for the general permit which outlines changes in the permit, key requirements, and addresses frequently asked questions * A Certificate of Coverage Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package please contact Aisha Lau of the Central Office Stormwater and General Permits Unit at (919) 733-5083, ext. 578 Sincerely, for Kerr T. Stevens cc: Central Files Stormwater and General permits Unit Files Raleigh Regional Office 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 Fax 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140035 STORVIWATER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, - READY MIXED CONCRETE-SANFORD is hereby authorized to operate a process wastewater treatment system, and is hereby authorized to discharge process wastewater and stormwater from it facility located at READY MIXED CONCRETE-SANFORD 320 MARKET ST SANFORD LEE COUNTY to receiving waters designated as Little Buffalo Creek in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, V, and VI of General Permit No. NCG140000 as attached. This certificate of coverage shall become effective August I, 1999. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day July 26, 1999. for Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission Slate of North'Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director February 24, 1995 J Randall Carlson Ready Mixed Concrete Company P.O. Box 688 Sanford, NC 27330 Subject: General Permit No. NCG 140000 Ready Mixed Concrete Company COC NCG 140035 Lee County . Dear I Randall Carlson : In accordance with your application for a stormwater discharge permit received on November 18, 1994, we are forwarding herewith the subject state - NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 .l and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1983. The stormwater permit you are receiving, NCG140000, does not permit wasting concrete, dumping excess concrete, directly into storm sewer outfalls or into waters of the state. Any facility which either dumps excess concrete or washes excess concrete into storm sewers or waters of the state will be operating in direct violation to both the terms of this permit and the North Carolina General Statutes. Such a discharge shall be considered an illegal discharge and may subject the owner to enforcement actions in accordance with North Carolina General Statutes 1.43-215.6A If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter. This request must be in the form of a written petition, conforming to Chapter 150B of the North' Carolina General Statutes, and filed with the Office of Administrative Hearings Post Office Drawer 27447, Raleigh, North Carolina 27611-7447. Unless such demand is made, this decision shall be final and binding. Please take notice that this certificate of coverage is not transferable. Part 11, B.2. addresses the requirements to be followed in case of change in ownership or control of this discharge. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Environmental Management or permits required by the Division of Land Resources. Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any question concerning this permit, please contact MS. AISHA LAU at telephone number 919/ 733-5083, extension 578. cc: Raleigh Regional Office Mr. Roosevelt Childress, EPA Sincerely. •`y A. Preston Howard, Jr. P.E. P.O. Box 29535, Raleigh, North Carolina 27626-0535 An Equal Opportunity Affirmative Action Employer Telephone 919-733-7015 FAX 919-733-2496 50% recycled/ 10% post -consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No NCG140035 STORMWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, otter lawful standards and _:regulations promulgated and adopted by the North Carolina Environmental Management Commission,_and-the,., Federal Water Pollution Control Act, as amended, Ready Mixed Concrete Company is hereby authorized to discharge stonnwater from a facility located at Ready Mixed Concrete Company 320 Market St. Sanford Lee County to receiving waters designated is Lithe Buffalo Creek in the Cape Fear River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III and IV of General Peoria No. NCG 140000 as attached. This Certificate of Coverage shall become effective February 24, 1995. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day February 24, 1995. A. Preston Howard, Jr., P.E., Director Division of Environmental Management By Authority of the Environmental Management Commission 0 r 0 a O W/JIM NCDENR Stormwater and General Permits Unit COC Number NCG140035 Facility Name Ready. Mixed County C&hIc. Co. Outfall Number 1 Date Sample Collected 10/14/1995 Certified Laboratory # 1 Certified Laboratory # 2 > 55 gall mo New Oil Usage N New Motor Oil Usage gal/month Total Event Precipitation 1.25 inches Event Duration 3.5 Hrs. �TIN { M hS. Ky VUQIk" Parameter Total Flow (MG) Total Suspended Solids (mg/1) ph (units) General Permit NCG140000 5tormwater Discharge Outfall Monitoring Report Data Entry Date 2/16/1996 Parameter VMA Total Flow (MG) VMA Oil & Grease (mg/1) VMA TSS (mgll) VMA MBAs (mg/1) VMA Lead jotal (mg/1) VMA pH (units) Submitt Value Submitt Value 0.066 NCDENR Stormwater and General Permits Unit COC Number NCG140035 Facility Name Ready Mixed County Ci%lc. Co. Outfall Number 2 Date Sample Collected 10/15/1995 Certified Laboratory # 1 Certified Laboratory # 2 > 55 gal/ mo New Oil Usage N New Motor Oil Usage gal/month :x Parameter Submitt Value Total Flow (MG) Total Suspended Solids (mg/1) ph (units) Total Event Precipitation 1.25 inches Event Duration 3.5 Hrs. General Permit NCG140000 "NINs Stormwater t' Discharge Outf all Monitoring Report t4C`0,4 ht'j �j rQ miData Entry Date 1�h�J 2/28/1996 Parameter VMA Total Flow (MG) VMA Oil & Grease (mg/1) VMA TSS (mg/1) VMA MBAs (mg/1) VMA Lead,Total (mg/1) VMA pH (units) 650 11.5 Submitt Value 0.066 NCDENR Stormwater and General Permits Unit COC Number NGG140035 Facility Name Ready Mixed County �lC. Co. - Outfall Number Date Sample Collected 7/12/1996 Certified Laboratory # 1 Certified Laboratory # 2 > 55 gall mo New Oil Usage New Motor Oil Usage gal/month Total Event Precipitation inches Event Duration Hrs. mw:e� Parameter Submitt Value Total Flow (MG) Total Suspended Solids (mgll) ph (units) General Permit NCG140000 Stormwater Discharge Outfall Monitoring Report Data Entry Date 9/24/1996 Parameter VMA Total Flow (MG) VMA Oil & Grease (mg/1) VMA TSS (mgll) VMA MBAs (mg/1) VMA Lead jotal (mg/1) VMA pH (units) Submitt Value I State of North Carolina Department of Environment and Natural Resources Raleigh Regional Office Michael F. Easley, Governor William G. Ross, Jr., Secretary CERTIFIED MAIL RETURN RECEIPT REQUESTED Division of Water Quality November 6; 2002 Mr. Larry Spence Ready Mix Concrete, Inc 3610 Bush Street Raleigh, NC 27609 AILT74 NC®NK NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: Notice of Violation Ready Mix Plant #7 NPDES Stormwater Permit NCG 140035 Sanford, NC Lee County Dear Mr. Spence: On October 18, 2002 Mr. Myrl Nisely of the Raleigh Regional office of Division of Water Quality made a compliance inspection at the Cary facility. The help provided by Mr. Ray Jeffries and Mr. Mike Setzer was appreciated. The results are as follows: Documentation requirements (the SPPP manual) were complete except for training records. Mr Setzer stated that videos are arriving soon and that training will be done the week of 10/21. We discussed how to document that session plus other stormwater related training given throughout the year. All employees are to receive stormwater and spill response training at least annually. The handling of stormwater/process wastewater in the water recycle system appears to be satisfactory, although two questions remain. How does the elevation of the recycle system compare to that of flood levels of the creek? Are there design calculations to show that the present water recycle configuration can control the stormwater and process wastewater in accordance with the permit? Mr. Setzer stated that in times when overflow threatens to occur, a local pump and haul company removes enough water to stay in compliance. The Division cannot consider this emergency pumping approach as satisfactory design engineering. On the other hand, recent observations were reported that a 5 to 6" rain was successfully contained. With potential storage in the 3000 and 500 gallon tanks, perhaps the present system can satisfy the permit with specific operating procedures. Sanford Ready Mix Concrete, November 6, 2002 p. 2 Measurements made in the last cell showed pH of 11.45, as well as a sample taken from the 500 gallon recycle tank. We bring to your attention a health note. High pH water (>I0) is strongly caustic, and is damaging to skin and eyes. Workers should use great caution in spaying down trucks or otherwise coming in contact with this water. On the Maple St. side of the plant various materials are stored. Runoff from that side of the plant collects in the concrete trough along Maple St. to form a point discharge. This runoff must also be sampled and identified on the plant site map. While no active process takes place, the runoff may still show pH and solids outside the limits. If so, this will require steps to meet the permit. On the location map for Part II Section A (I.)(a) please prepare a USGS-type map "zoomed in" somewhat closer to show the facility's location in reference to transportation routes (as the present map does) as well as where all stormwater discharges from the property. Identify the surface receiving stream. Please send a copy of this map to the Division. A change is also requested on the plant site map. Please designate the approximate areas being served by each discharge point (Section A(1)(c)). Also send a copy of this map to the Division. Please respond in writing within 30 days of receipt of this letter. If you have any comments or questions, contact Myrl Nisely at 919-571-4700. Sincerely, 1111___�ZQ Kenneth Schuster, P.E. Regional Supervisor cc: NPDES Compliance Unit Lee Co. Health Dept. Central Files 1628 Mail Service Center, Raleigh, NC 27699-1628 Telephone (919)571-4700 FAX (919)571-4718 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer paper 0 1 Michael F. Easley, Governor d % William G. Ross Jr.. Secretary North Carolina Department of Environment and Natural Resources 12/13/2002 CERTIFIED MAIL RETURN RECEIPT REQUESTED Preston Satterfield Ready Mixed Concrete PO Box 688 Sanford NC 27330 Alan W. Klimek, P.E. Director Division of Water Quality SUBJECT: NOTICE OF VIOLATION AND REVOCATION FOR NON PAYMENT PERMIT NUMBER NCG140035 Ready Mixed Concrete -Sanford Lee COUNTY ✓ / Dear Permittee: 3 Payment of the required annual administering and compliance monitoring fee of $80.00 for this year has not been received for the subject permit. This fee is required by Title 15 North Carolina Administrative Code 2H.0105. under the authority of North Carolina General Statutes 143-215.3(a)(1), (1a) and (1b). Because this fee was not fully paid within 30 days after being billed, this letter initiates action to revoke the subject permit, pursuant to 15 ncac 2H.0105(b) (2) (k) (4), and G.S. 143-215.1 (b) (3). Effective 60 days from receipt of this notice, subject permit is hereby revoked unless the required Annual Administering and Compliance Monitoring Fee is received within that time. Discharges without a permit are subject to the enforcement authority of the Division of Water Quality. Your payment should be sent to: N.C. Department of Environment and Natural Resources Division of Water Quality Budget Officd 1617 Mail Service Center Raleigh. NC 27699-1617 If you are dissatisfied with this decision, you have the right to request an administrative hearing within Thirty (30) days following recipt of this notice, identifying the specific issues to be contended. This request must be in the form of a written petition conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings, Post Office Drawer 27447, Raleigh, North Carolina, 27611-7447. Unless such request for hearing is made or payments received, revocation shall be final and binding. If you have any questions, please contact: Mr. Ken Schuster, Raleigh Water Quality Regional Supervisor, (919) 571-4700. cc: Supevisor, Water Quality Permits and Engineering Unit Raleigh Regional Office County Health Department Sincerely, Alan W. Klimek, P.E. P.O. Box 29535, Raleigh, North Carolina 27626-0535 An Equal Opportunity Affirmative Action Employer Telephone 919-733-5083 FAX 919-733-9919 50% recycled / 10% post -consumer paper State of North Carolina Department of Environment and Natural Resources Raleigh Regional Office Michael F. Easley, Governor William G. Ross, Jr., Secretary CERTIFIED MA[L RETURN RECEIPT REQUESTED Division of Water Quality October 23, 2002 Mr. Larry Spence Ready Mix Concrete, hic 3610 Bush Street Raleigh, NC 27609 INK? wir"AA NCDENii ENVIRONMENT AND NATURAL. RESOURCES Subject: Notice of Violation Ready Mix Plant #7 NPDES Stormwater Permit NCG 140035 Sanford, NC Lee County Dear Mr. Spence: On October 18, 2002 Mr. Myrl Nisely of the Raleigh Regional office of Division of Water Quality made a compliance inspection at the Cary facility. The help provided by Mr. Ray Jeffries and Mr. Mike Setzer was appreciated. The results are as follows: Documentation requirements (the SPPP manual) were complete except for training records. Mr Setzer stated that videos are arriving soon and that training will be done the week of 10/21. We discussed how to document that session plus other storniwater related training given throughout the year. All employees are to receive stormwater and spill response training at least annually. The handling of stormwater/process wastewater in the water recycle system appears to be satisfactory, although two questions remain. In a 10 year, 24 hour storm (about 5.6" in this area), will the creek rise enough to flood into the system? Are there design calculations to show that the present water recycle configuration can control the rain from a 10 year storm? Mr. Setzer stated that in times when overflow threatens to occur, a local pump and haul company removes enough water to stay in compliance. The Division cannot consider this emergency pumping approach as satisfactory design engineering. On the other hand, recent observations were reported that a 5 to 6" rain was successfully contained. With potential storage in the 3000 and 500 gallon tanks, perhaps the present system can satisfy the permit with specific operating procedures. Sanford Ready Mix Concrete, October 18, 2002 p. 2 Measurements made in the last cell showed pH of 11.45, as well as a sample taken from the 500 gallon recycle tank. We bring to your attention a health note. High pH water (>10) is strongly caustic, and is damaging to skin and eyes. Workers should use great caution in spaying down trucks or otherwise coming in contact with this water. You might want to consider the possibility that if used to clean up at a customer's site, this water may damage grass, as well. On the Maple St. side of the plant various materials are stored. Runoff from that side of the plant collects in the concrete trough along Maple St. to form a point discharge. This runoff must also be sampled and identified on the plant site map per Part 11 Section B(1). While no active process takes place, the runoff may still show pH and solids outside the limits. On the location map for Part II Section A (l.)(a) please prepare a USGS-type map "zoomed in" somewhat closer to show the facility's location in reference to transportation routes (as the present map does) as well as where all stormwater discharges from the property. Identify the surface receiving stream. Please send a copy of this map to the Division. A change is also requested on the plant site map. Please designate the approximate areas being served by each discharge point (Section A(1)(c)). Also send a copy of this map to the Division. Please respond in writing within 30 days of receipt of this letter. If you have any comments or questions, contact Myrl Nisely at 919-571-4700. Sincerely, Kenneth Schuster, P.E. Regional Supervisor cc: NPDES Compliance Unit Lee Co. Health Dept. Central Files 1628 Mail Service Center, Raleigh, NC 27699.1628 Telephone (919)571-4700 FAX (919)571.471 An Equal Opportunity Affirmative Action Employer 50% recycled/10% post -consumer pape Guaranteed READY MIXED CONCRETE COMPANY 3610 Bush Street, Ifti'u1'U'T: UU-i JLU , �t March 26, 2002 Randy Jones DENR Raleigh Regional Office 1628 Mail Services Center Raleigh, N.C. 27699-1628 Dear Randy, P.O. Box 27326, Raleigh, NC 27611 Referencing the phone conservation that you and I had March 26, 2002 about the recycling equipment that we installed at our Sanford plant. We installed a water filter from Pump Systems, Inc to recycle water from the wash down of our mixer trucks. This water is being reused in the making of fresh concrete, replacing city water. We are trying to recycle all the process water that we have in our batching process. What we are wanting is a Tax Certification to obtain tax benefits in keeping with the General Statutes of North Carolina. Randy the plant is located at 320 Market Street Sanford, NC. Mike Setzer is our Division Manager working out of that office. You can reach Mike at G(919) l776-8359. �1,1 Aj99 - 35/8�-� �013f L� If I can be of any more help please give me a II (19) 790-1520. 1 have also enclosed a copy of the equipment cost for your information. (9JO) 25,5_ 65'l ( P1/VE/tV/25 T Sincerely, G� rry Spence Assets Manager Ready Mixed Concrete Co. Member National Ready Mixed Concrete Association 'PumpSystems, Inc. 420 N. Main St. Kemersville, N.C. 27284`1 Phone: (336) 992-2929 � N0, Fax: (336) 992-0912 pumpsystems®yahoo.com ,4. 'ysBILL TOIu ��'�"i yn�+�,'q...a *r%..-n.kt:P.v. Ready Mixed Concrete Co. P.O. Box 27326 Raleigh, NC 27611 INVOICE 8 DATE:ix�{irw�i. ~>INVOICE#.S:Y 6/5/2001 01-3291 d7m `Fl"i Ta 1RGfl,»f c.% ITT Ready Mixed Concrete Co. 320 Market St. / Sanford, NC 27331 Y Attn: Lyman Austin FRT FACTORY 00 O.00T 0.00 0.00 6.00% 357.00 PAST DUE INVOICE SUBJECT TO 1.5% MONTHLY SERVICE CHARGE AFTER 30 DAYS FROM DATE OF INVOICE. Thank you for your business. TOTAL I $6,307.00 VulnpSystems, Inc. f, 420 N. Main St. Kemersville, N.C. 27284,1�. ti Phone: (336) 992-2929 Fax: (336) 992-0912 pumpsystems®yahoo.com �\ NCR H Ready Mixed Concrete Co. P.O. Box 27326 Raleigh, NC 27611 w ar hx L. Austin Net 30 w� INVOICE paiE- m ainv� 611V2001 01-3428 Ready Mixed Concrete Co. 320 Market St. Sanford, NC 27331 Attn: Lyman Austin FRT F. PAST DUE INVOICE SUBJECT TO 1.5% MONTHLY SERVICE CHARGE AFTER 30 DAYS FROM DATE OF INVOICE. nk you for your business.. _ TOTAL $s9s5 Afes... lCgG Z 4 i STORMWATER POLLUTION PREVENTION PLAN DEVELOPMENT AND IMPLEMENTATION CERTIFICATION N.C. Division of Water Quality, Stomnvater and General Pei7nits Unit Facility Name: READY MIXED CONCRETE-SANFORD COC Number: NCG140635 Location Address: 320 M RKET ST SA RD, NC 27330 County: E POINT SOURGI, tSRAnl.n " I certify, under penalty of law, that the Stormwater Pollution Prevention Plan (SP ) document and all attachments were developed and implemented under my directien or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information required by the SPPP. Based on my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information gathered is, to the best of my knowledge and belief- true- accurate. and complete" "I certify that the SPPP has been developed, signed and retained at the facility location and the SPPP has been fully implemented at the named facility location in accordance with the terms and conditions of the stormwater general permit." "I am aware that there are significant penalties for falsifying information- including the possibility of fines and imprisonment for knowing violations" Sign (according to permit signatory requirements) and return this Certification. Return within 30 days of receipt if the date on your initial Certificate of Coverage is hefore August 1, 1999. If your initial Certificate of Coverage was issued after August 1, 1999. sign and return this Certification within 31) days of implementation of your Stormwater Pollution Prevention Plan. DO NOT SEND THE STORNIWATER POLLUTION PREVENTION PLAN WITH THE CERTIFICATION. Sienature Dale cti d A E— L4 Print'or type name of person signing above Title Please Return to: Division of Water Quality/ WQ Section Stormwater and General Permits Unit 1617 Mail Service Center Raleigh, North Carolina 27699-1617 .SPIT Ccrtificmiurt 07/99 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10 % post -consumer paper State of North Carolina Department of Environment and Natural Resources Division of Water Quality James B. Hunt, Jr., Governor Wayne McDevitt, Secretary Kerr T. Stevens, Director July 26, 1999 PRESTON SATTERFIELD READY MIXED CONCRETE-SANFORD P.O. BOX 688 SANFORD, NC 27330 �® MCDENR NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES Subject: Reissue - NPDES Stormwater Permit Ready Mixed Concrete -Sanford COC Number NCG140035 Lee County Dear Permittee: In response to your renewal application for continued coverage under general permit NCG 140000, the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983. The following information is included with your permit package: * A copy of general stormwater permit NCG140000 * A Stormwater Pollution Prevention Plan (SPPP) Certification Form. Completion of this form is required to certify that you have developed and implemented the SPPP as per the conditions of the permit. This form must be completed and returned to the Division within 30 days of receipt of this letter. DO NOT SEND the SPPP with the Signed form - Five copies of the Analytical Monitoring form and five copies of the Qualitative Monitoring form * A copy of a Technical Bulletin for the general permit which outlines changes in the permit key requirements. and addresses frequently asked questions * A Certificate of Coverage Your coverage under this general permit is not transferable except after notice to D`,VQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance. order, judgment, or decree. If you have any questions regarding this permit package please contact Aisha Lau of the Central Office Stormwater and General Permits Unit at (919) 733-5083, ext. 578 Sincerely. for Kerr T. Stevens cc: Central Files Stormv ':er and General permits Unit Files Rsleiah Regional Office 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 Fax 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10%post-consumer paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG140000 CERTIFICATE OF COVERAGE No. NCG140035 STORMWATER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended. READY MIXED CONCRETE-SANFORD is herebv authorized to operate a process wastewater treatment system. and is hereby authorized to discharge process wastewater and stormwater from a facility located at READY MIXED CONCRETE-SANFORD 320 MARKET ST SANFORD LEE COUNTY to receiving waters designated as Little Buffalo Creek in the Cape Fear River Basin in accordance with the effluent limitations. monitoring requirements. and other conditions set forth in Parts I. II. III. IV, V. and VI of General Permit No. NCG140000 as attached. This certificate of coverage shall become effcctice August 1. 1999. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day July 26, 1999. for Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission ,tvorth Carolina ,Wt ment of Environment, Alth and Natural Resources ivision of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director J Randall Carlson Ready Mixed Concrete Company P.O. Box 688 Sanford, NC 27330 Dear J Randall Carlson February 24, 1995 Subject: General Permit No. NCG 140000 Ready Mixed Concrete Company COC NCG 140035 Lee County . In accordance with your application for a stornlwater discharge permit received on November 18, 1994, we, are forwarding herewith die subject state - NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1.983. 'Fhe storruwater permit you are receiving, NCG140000, does not permit wasting concrete, dumping excess concrete, directly into storm sewer outfalls or into waters of the state. Any facility which either dumps excess concrete or washes excess concrete into storm sewers or waters of the state will be operating in direct violation to both the terms of this permit and the North Carolina General Statutes. Such a discharge shall be considered an illegal discharge and may subject the owner to enforcement actions in accordance with North Carolina General Statutes 143-215.6A It' any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to YOU. you have the right to an adjudicatory hearing upon written request within thirty (30) days following receipt of this letter.. This request must be in the form of a written petition, conforming to Chapter 150B of the North Carolina General Statutes, and filed with the Office of Administrative Hearings Post Office Drawer 27447, Raleigh, North Carolina 27611-7447. Unless such demand is made, this decision shall be final and binding. Please take notice that this certificate, of coverage is not transferable. Part 11, B.2. addresses the requirements to be followed in case of change in ownership or control of this -discharge. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any question concerning this permit, please contact MS. A1SHA LAU at telephone number 919/ 733-5083, extension 578. cc: Raleigh Regional Office Mr. Roosevelt Childress, EPA Sincercl}�, A. Preston Howard, Jr. P.E. P.O. Box 29535, Raleigh, North Carolina 27626-0535 An Equal Opportunity Affirmative Action Employer Telephone 919-733-7015 FAX 919-733-2496 50% recycled/ 10% post-consurner paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL RESOURCES DIVISION OF ENVIRONMENTAL MANAGEMENT GENERAL PERMIT NO NC 14 000 CERTIFICATE OF COVERAGE No. N G140 35 STORMWATER DISCHARGES NATIONAL POLLUTANT DIS IIARGG FI IMINA"r1UN SYSTEM In compliance with die provision of North Carolina General Statule 143-215.1, otherlawful standards and —arcgulations promulgated and adopted by the North Carolina Euvirouutentat Management Commission;-and_the-._ Federal Water Pollution Contiol Act, as amended, Ready Mixed Concrete Company is hereby authorized to discharge stonnwatcr from a facility located at Ready Mixed concrete Company 320 Market St. Sanford Lee County to receiving waters designated as Little Buffalo Creck in the Cape Fear River Basin in accordance with the effluent limitations, monitoring rquircnhcnts, and other conditions set fordi in Pans 1, 11, HI and IV of General Permit No. NCG140000 as attached. 'rhis Certificate of Coverage shall become effective February 24, 1995. This Certificate of Coverage shall remain in effect for life duration of tlhc General Permit. Signed this day February 24, 1995. A. Preston Howard, Jr, P.E., Director Division of Environmcntal Management By Authority of the Environmental Management Commission I I m I o 00 00 I O 9 - .- 1.0 qo W � a z I � n I y D 1 1 1 I El N ID -ATLANTIC Engrneeriug ASSOCIATES, INC. & EnvhmmewdSoludons REFERENCE: MID —ATLANTIC FIELD NOTES. lom J 40 V# 4A Ll SITE MAP READY MIXED CONCRETE ' PLANT #7 320 MARKET STREET SANFORD, NORTH CAROLINA -40 DRAWN DATE: JUNE 2003 BY: DRAFTING CHECK BY: ,JOB NO: OOOR1255.02 ,/ ENGINEER CHECK BY: CAD # 01-125540-02 APPROVED tlf iM DWG N0: 3.2 COC_NUMBER OUTFALL_l DATE_SAMPL NCG 140035 1 10/14/ 1995 NCG140035 2 10/15/1995 NCG140035 0 7/12/1996 NCG 140035 8/12/2004 TOTA L_FLO W 0.000000 0.000000 0.000000 PH TOTAL_SUSP NEW_MOTOR_ 8.70 180.00 N 11.50 650.00 N 9.68 59.00 7.90 55.00 COUNTY TOTAL EVEN EVENT_DURA PACILITY_N Lee 1.25 3.50 Ready Mixed Conc, Co. Lee 1.25 3.50 Ready Mixed Conc. Co. Lee 0.00 0.00 Ready Mixed Conc. Co. - Sanford VMA_TOTAL_ VMA_OIL_ VMA_TSS VMA_MBAS_ VMA_PFI_UN 0.066 0.00 0.0 0.00 0.00 0.066 0.00 0.0 0.00 0.00 0.000 0.00 0.0 0.00 0.00 n -13,11V , 41 I m sae oA►r � ..,.w AddONOW _d