Loading...
HomeMy WebLinkAboutNCG020898_COMPLETE FILE - HISTORICAL_20161129f'�7D STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. /v �� (� a (A DOC TYPE HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ j u I�/ l l a YYYYMMDD i MCCRORY JAN - 4 2017 ` avernw DONALD R. VAN DER VAART . �r. •c.1,p r,,.,,ml rttlRilrti,',n„):tq„p secretor. Energy, Mineral and Land Resources ENVIRONMENTAL OLIALITV November 29, 2016 Isaac Goodwin Sea Level Mine, LLC 203 Willis Road Harkers Island, NC 28531 TRACY DAVIS D4eaor 9 DEC 18 2015 j Subject: General Permit No. NCG020000 Winding Creek Quarry COC NCG020898 Chatham County Dear Mr. Goodwin: In accordance with your application for a discharge permit received on August 11, 2016, we are forwarding herewith the subject certificate of coverage to discharge under the subject state — NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143- 215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please take notice that this certificate of coverage is not transferable except after notice to the Division of Energy, Mineral, and Land Resources. The Division may require modification or revocation and reissuance of the certificate of coverage. Please be aware that mine dewatering at your site has the potential to impact adjacent wetlands. The specific requirements for mine dewatering at facilities near wetlands can be found in Part III, Section E of your permit. You must have an approved Operation and Monitoring Plan before mine dewatering discharges occur at your facility. Discharging mine dewatering wastewater without Plan approval will be subject to enforcement action. An Operation and Monitoring Plan for your facility must be submitted to the Wilmington Regional Office within 60 days of your receipt of this permit. Contact Dan Sams at the Wilmington Regional Office at (910) 796-7215 for more information about the approval process. Please note that mine dewatering wastewater includes wet pit overflows caused solely y direct rainfall and groundwater seepage for this type of mining operation. Any discharge of this water (and any stormwater commingled with it) is subject to the effluent limitations in this permit. This general permit allows the discharge of stormwater and certain types of wastewater from your facility. In your application, you specified that only mine dewatering water would be discharged from this facility. If separate point -source discharges of stormwater occur (i.e., stormwater not combined with mine State or North Carolina I Environmental Quality I Energy, Mineral and Land Resources 1612 Mail Service Center 1 512 North Salisbury Street I Raleigh, NC 27699-1612 919 707 9200 T dewatering water), you will be required to adhere to the conditions in this permit for stormwater discharges. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Energy, Mining, and Land Resources, or permits required by the Division of Water Resources, Coastal Area Management Act, or any other federal or local governmental permit that may be required. If you have any questions concerning this permit, please contact Richard Riddle at telephone number (919)807-6375. Sincerely,. CRIGINALSIGNED BY MICHEAL F RANDALL for Tracy E. Davis, P.E., CPM cc: Wilmington Regional Office Central Files Stormwater Permitting Program Files State0fNx&Camlim I Eaiio til Quatiryl EnM-,]Sanal aodLod Rexnnces 16L\sit Senice Center 1512N�&S69mrySmet I Raleioh �X27MIW 919 707 9:00 T STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCG020908 STORM WATER AND MINE DEWATERING DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Sea Level Mine LLC is hereby authorized to discharge stormwater and mine dewatering-from a facility located at Sea Level Mine 1001 Nelson Bay Drive Sea Level Carteret County to receiving waters designated as Nelson Bay, a class SC water in the Tar -Pamlico River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, and V of General Permit No. NCG020000 as attached. This certificate of coverage shall become effective November 29, 2016. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day November 29, 2016. ORIGINAL SIGNED By MICHEAL F RANDALL for Tracy E. Davis, P.E., Director Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission ° (A)1 ekfJ1 w/ Aw1t• 141W Sh-1.1 • Aawf�; atil, �f Isf. Swv ur+i wl(1,� (7C cci d, —r �.-.1.__—t_46A,_�u� NCG020908 0 Sea Level Mine Latitude: 340 53' 01" N Longitude: -760 23' 4314" W County: Carteret Receiving Stream: Nelson Bay Stream Class: SC p�w:N7�pl�L��j1�\ srj% I Map Scale 1:24,000 Index Number: 21-35-7-10-(1) (Tar-Palmlico Basin) Facility Location Permit Number NCG020898 Program Category NPDES SW Permit Type Mining Activities Stormwater Discharge CDC Primary Reviewer rick.riddle Coastal SWRule Permitted Flow Facility Name Winding Creeks Quarry Location Address US Hwy 421 Bear Creek Owner NC 27207 RECEIVED OCT 21 MIS CENTRAL FILES DWR SECTION Central Files: APS _ SWP _ 1012012016 Permit Tracking Slip Status Project Type Active New Project Version Permit Classification 1.00 CDC Permit Contact Affiliation Major/Minor Region Minor Raleigh County Chatham Facility Contact Affiliation Bobby A. Branch PO Box 61 Gulf NC 27256 Owner Name Owner Type Winding Creek Holdings LLC Non -Government Owner Affiliation Bobby A. Branch / Manager Member 402 Forestwood Park Dr Dates/Events Sanford NC 27330 Scheduled Ong Issue App Received Draft Initiated Issuance Public Notice ,Issue Effective Expiration 10/19/2016 2/23/2016 10/19/2016 10/19/2016 9/30/2020 Regulated Activities Requested /Received Events Mining activities - stormwater discharges RO staff report received 10/19/16 RO staff report requested 3/11/16 Outfall 1 Waterbody Name Streamindex Number Current Class Subbasin Bear Creek 17-43-16 C 03-06-12 R Energy, Mineral and Land Resources ENVIRONMENTAL QUALITY October 19, 2016 Bobby A. Branch Roscoe Road Holdings, LLC P.O. Box 61 Gulf, NC 27256 PAT MCCRORY (imcmor DONALD R. VAN DER VAART Secmlary TRACY DAVIS Du-,, ar Subject: General Permit No. NCG020000 Winding Creek Quarry COC NCG020898 Chatham County Dear Mr. Branch: In accordance with your application for a discharge permit received on February 23, 2016, we are forwarding herewith the subject certificate of coverage to discharge under the subject state — NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143- 215.1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection Agency dated October 15, 2007 (or as subsequently amended). Please take notice that this certificate of coverage is not transferable except after notice to the Division of Energy, Mineral, and Land Resources. The Division may require modification or revocation and reissuance of the certificate of coverage. Please note that mine dewatering wastewater includes wet pit overflows caused solely y direct rainfall and groundwater seepage for this type of mining operation. Any discharge of this water (and any stormwater commingled with it) is subject to the effluent limitations in this permit. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Energy, Mining, and Land Resources, or permits required by the Division of Water Resources, Coastal Area Management Act, or any other federal or local governmental permit that may be required. If you have any questions concerning this permit, please contact Richard Riddle at telephone number (919)807-6375. Sin c INALSIGNEDBY MICHEAL F RANDALL for Tracy E. Davis, P.E., CPM cc: Raleigh Regional Office Central Files Stormwater Permitting Program Files State of Nonh Carolina I Environmental Quality � Energy, Mineral and Land Resources 1612 Mail Service Center 1 512 North Salisbury Street I Raleigh, NC 27699-1612 919 707 9200 T STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENTAL QUALITY DIVISION OF ENERGY, MINERAL, AND LAND RESOURCES GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCG020898 STORMWATER AND MINE DEWATERING DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Winding Creek Holdings, LLC is hereby authorized to discharge stormwater and mine dewatering-from a facility located at Winding Creeks Quarry US Highway 421 Bear Creek Chatham County to receiving waters designated as Bear Creek, a class C water in the Cape Fear River Basin, in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1,11, III, IV, and V of General Permit No. NCG020000 as attached. This certificate of coverage shall become effective October 19, 2016 This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day October 19, 2016. 0RC4 AI.SIGNEDgY MICHEAL F RAHDALL for Tracy E. Davis, P.E., Director Division of Energy, Mineral, and Land Resources By the Authority of the Environmental Management Commission NCG020898 Map Scale 1:24,000 Winding Creek Holdings, LLC Winding Creek Quarry Latitude: 350 37' 8.5" N Longitude: -790 22' 48" W County: Chatham Receiving Stream: Bear Creek Stream Class: C Index Number: 17-43-16 (Cape Fear River Basin) Facility Location Riddle, Rick L From: Wehner, Judy Sent: Tuesday, April 12, 2016 9:38 AM To: Riddle, Rick L Subject: RE: Winding Creek Quarry - Chatham Co, Yes. WEjust got it. Review is not complete. From: Riddle, Rick L Sent: Tuesday, April 12, 2016 8:34 AM To: Weimer, Judy <judy.wehner@ncdenr.gov> Subject: Winding Creek Quarry - Chatham Co, Good morning Judy, Hope you are well on this rainy Tuesday. Do you have a permit for Winding Creek in Bear Creek, NC, Chatham Co? If so, what is the status of the permit? Thanks Richard L. Riddle, Jr. Stormwater Engineer North Carolina Department Enviromental Quality North Carolina Division Energy Mineral Land Resources 919 803-6375 office rick.riddle cDr cdenr gov 512 North Salisbury Street 1612 Mail Service Center Raleigh, NC 27699-1612 �'•.� Nothing Compares�, w Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. Riddle, Rick L From: Riddle, Rick L Sent: Friday, March 11, 2016 9:01 AM To: Holley, John Subject: NCG020898 Winding Creek Quarry Attachments: NCG020898_Winding Creek_NOI.pdf John Holley: Another mine! Please review the attached NOI application and let me know of any recommendations for the permit. will forward you a copy of the site plan via mail. ICOC # IFacility (Location ICity/County INCG020898 I Winding Creek Quarry IUS Highway 421 (Bear Creek/Chatham If you need any more info, give me an email or call. If you could send me a recommendation for the permit by 4/1 1 /2016 so I can issue their COC, I'd appreciate it. Have a great day. Thank you. Richard L. Riddle, Jr. Stormwater Engineer North Carolina Department Enviromental Quality North Carolina Division Energy Mineral Land Resources 919 803-6375 office rick.riddle(@ncdenr.gov 512 North Salisbury Street 1612 Mail Service Center Raleigh, NC 27699-1612 Nothing Compares�, Email correspondence to and from this address is subject to the North Carolina Public Records Law and may be disclosed to third parties. © Division of Water Quality / Surface Water Protection NCDENR National Pollutant Discharge Elimination System NORIII c .. oo+NneNr or EMwNwMEM Wo Nmw4 fR au+rE+ NCG020000 NOTICE OF INTENT FOR AGENCY USE ONLY Date Received Year Month Day Certilimtc of Coverage NCG02A Check WAWouAtt Peooit Assikned to KitkAle National Pollutant Discharge Elimination System application for coverage under General Permit NCG020000: STORMWATER DISCHARGES associated with activities classified as: SIC (Standard Industrial Classification) Code -14XX Mineral Mining Industry (except a9 W1:11AMAIAV) The following activities are also included: DENR-LAND QUALITY STORMWATER PERMIT"iING Active or inactive mining operations (including borrow pits —except for NCDOT borrow pits) that discharge stormwater contaminated with or that has come in contact with, any overburden, raw material, intermediate products, finished products, byproducts or waste products located on the site of such operations, Stormwater from vehicle maintenance activities at mining operations; Overflow from facilities that recycle process wastewater; and/or Mine dewatering (wastewater) The following activities are specifically excluded from coverage under this General Permit: Stormwater discharges associated with peat mining, coal mining, and metal mining; Stormwater discharges from mining operations which are intermixed on site with stormwater from asphalt operations and/or concrete operations; Stormwater discharges associated with oil and gas extraction operations; and Stormwater discharges associated with tourist gem mines NCDOT borrow pits are covered under NCS000150 The following discharges are covered by NPDES general permit NCG520000 instead of NCG020000: Point source discharges of stormwater and wastewater from in -stream sand mining operations (i.e., sand dredging or dipping operations). Please contact the NPDES Wastewater Point -Source Group for more information on coverage under this Please print or tvpe all entries in this application form 1) Mailing address of owner/operator (official address to which all permit correspondence will be mailed): Legal Owner Name _ Winding Creek Holdings LLC (Attach the most recent Annual Report to the NC Secretary of Slate showing the current legal name of the corporation or entity. Alternatively this permit can be given to an individual or government authority. This name must be the same name as appears on the Division of Land Resources' Mining Permit.) Signee's Name (as signed for in permit signature at bottom) Bobby A. Branch Street Address P.O. Box 61 City Gulf State NC ZIP Code 27256 Telephone No. 919-708-8465 Email redmud(�windstream.net Alternate Contact Name Russ Patterson _ Email (if different) russ(aD_pattersonexploration.com Alternate Contact Telephone (if different) 919-774-3770 Page 1 of 8 SWU-NCG02-NOI Last revised 9/5/2012 NCG020000 N.O.I. 2) Location of facility producing discharge: Facility Name Winding Creeks Quarry Facility Street Address US Highway 421 Facility City Bear Creek State NC ZIP Code 27207 Facility County Chatham Facility Contact Bobby A. Branch Telephone No. 919-708-8465 Fax: no fax Contact E-mail redmudfaawindstream.net 3) Physical Location Information: Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). SE of the intersection of US 421 and NC 902, near Roscoe Road, must east of Bear Creek, NC. Center of site coords given below 4) Latitude 35" 37' 08.58" N Longitude 0790 22' 48.23" W (degrees, minutes, seconds) Permits: 5) This NPDES Permit Application applies to which of the following: X New or Proposed Facility ❑ Existing 6) Standard Industrial Classification: Date operation is to begin: Mid 2016 Date began mining: Provide the 4 digit Standard Industrial, Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code: 14 2 3 7) Provide a narrative description of the types of minerals mined at this facility: Metagravwacke will be mined to produce construction aggregate. 8) Is this mine an inactive mine site? X No ❑ Yes If yes, do you posses an "Inactive Renewal" from DEMLR and notified the DWQ Regional Office or have you certified to the DWQ that the site has been stabilized? ❑ No ❑ Yes 9) Does this facility already have a valid Mining Permit from the Division of Energy, Mineral and Land Resources (DEMLR) [formerly DLR]? X No If No, please indicate the status of the Mining Permit application: Permit has been submitted ❑ Yes If yes, please provide the Mining Permit number: Please also provide a copy of your DEMLR Mining Permit with this DWQ application. Note: DWQ cannot issue a COC for the NCGO20000 General Permit until a Mining Permit is issued or renewed by the DEMLR. 10) Does this facility have any other NPDES permits? X No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: Page 2 of 8 SWU-NCG02-NOI Last revised 9/5/2012 NCG020000 N.O.I. 11) Are you applying for a mining permit in the same location as a previously permitted mine? X No ❑ Yes If yes, specify permit number and name if known: 12) Does this facility have any Non -Discharge permits (ex: recycle permits)? X No ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: 13) Does total area of this mine site include ready -mix and asphalt areas? X No ❑ Yes If yes, do they have DWQ stormwater permits (if owned by the same company)? ❑ No ❑ Yes (provide permit number ) If not owned by the same company, who is the owner? 14) Will this mining operation precede development activities at this site? X No ❑ Yes 15) Is this mine located within one of the 20 Coastal Counties and will it add more than 10,000 ft2 of impervious surface? X No ❑ Yes If yes, you may be required to apply for an additional state stormwater permit. Check with your local Regional Office. See contact information and checklist below. 16) Is this mine located the Neuse, Tar -Pamlico, or Catawba River Basins, or the Randleman or Jordan Water supply Watersheds? X No ❑ Yes If yes, what size stream buffers are included on site? ft. Please show buffers in site plans. If yes, please include information and plans showing diffuse flow through buffers as required. Discharge Points Receiving Waters & Wetlands: 17) Receiving waters: What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater and/or wastewater discharges end up in? Tributary (intermittent) of Bear Creek If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). NA Receiving water classification (if known): Note: Discharge of industrial wastewater to receiving waters classified as WS-11 to WS-V, or SA, must be approved by the Div. of Water Resources, or Div. of Marine Fisheries. If DWR or DMF does not approve, coverage under NCG020000 cannot be granted. No new discharges of wastewater are permitted in receiving waters classified as WS4 or freshwater ORW. Wastewater discharges to Saltwater ORW will not be approved under the NCG02 General Permit. 18) If your facility has wastewater discharges and they are to HWQ and/or PNA waters (Primary Nursery Areas) waters, what is the proposed flow rate? NA (See http //www.ncdmf.netitnaps/FNA maps/index html, for map) Page 3 of 8 SWU-NCG02-NOI Last revised 9/5/2012 NCG020000 N.O.I. 19) Discharge Points: Number of discharge points (ditches, pipes, channels, etc. that convey discharges from the property): Onsite: Stormwater: 5 _ Mine dewatering: 1 Process Wastewater Overflow: Offsite: Stormwater: Mine dewatering: Process Wastewater Overflow: Discharge points should be clearly marked on the submitted site plan. Please provide short narrative description of discharges: Site has two intermittent streams (tributaries of Bear Creek) that borders the east & west sides of the site. Most drainage will eventually make it to these streams. Storm water and pit water will be directed to the sediment basins and recycled for process water. Except during initial construction activities and major storm events, most runoff will be used. Make up process water will be from a planned well to be constructed on the plant site. a) Is your mine dewatering and discharging? (Answer only if you are dewatering) ❑ No ❑ Yes If yes, where to? _Surface Waters and/or Wetlands (on -site or off -site) Other (on -site or off -site) Describe: b) Are you dewatering but not discharging? (Answer only if you are dewatering) ❑ No XYes If Yes, please explain how you are dewatering, and where that water will be directed: When mining starts and dewatering is necessary, mine water will be directed to Sediment Basin #6 to be recycled 20) Will mining operations require dewatering near wetlands or impact any stream, groundwater, or wetlands? X No ❑ Yes Note: Wetlands must be CLEARLY DELINEATED on the site plan. Mine dewatering activities that have the potential to drain wetlands or otherwise impact surface water or groundwater MUST develop and implement a Pumping Operation and Monitoring (O&M) Plan that has been approved by the Division. For sites that may drain wetlands — approval of a Pumping O&M plan may be required prior to coverage under this general permit. The Pumping O&M Plan should be submitted to the appropriate Regional Office and must be approved prior to operation. The plan shall include, but is not limited to: (1) Groundwater monitoring strategies to demonstrate the effect of pumping and to establish any pumping regime necessary to reduce impacts, and (2) Detailed plans to maintain surrounding hydrology and respective monitoring to demonstrate compliance. See checklist at end of document. Contact your local Regional Office for questions specific to your mine. 21) If you are dewatering, are there wetlands or surface waters within 400' of the mine pit perimeter? No Within 400' an intermittent tributary of Bear Creek X Yes If yes, what distance are they from the mine pit perimeter? 100-380 feet. 22) Have you been required to obtain a 404/401 Certification permits? X No ❑ Yes If yes, please briefly describe below (include information such a required mitigation, BMPs, setbacks, and/or O&M plans for on or off -site wetlands or other pertinent information). Attach other sheets as necessary: Page 4 of 8 SWU-NCG02-NOI Last revised 9/52012 NCG020000 N.O.I. 23) Have you been required to obtain a wetland delineation certified by the US Army Corps of Engineers? X No ❑ Yes If yes, please attach to application submission. Stormwater BMPs: 24) Does this facility employ any best management practices for stormwater control? ❑ No X Yes If yes, please briefly describe: Sediment Traps and Basins are constructed at discharge points Disturbed areas are reseeded where practible. See Mine Map 6 Plans for Details 25) Does this facility have a Stormwater Pollution Prevention Plan? X No ❑ Yes If yes, when was it implemented? 26) Will vehicle maintenance activities occur at this facility? X No ❑ Yes Wastewater Treatment Facilities: 27) Will mine dewatering discharges occur? X No ❑ Yes 28) Will discharges of overflows from process wastewater treatment systems occur? X No ❑ Yes If yes, a. Does this facility employ chemical additives to flocculate suspended solids? X No ❑ Yes If yes, please state the name, manufacturer and the quantity of average daily usage of the chemical additive Note: Please see our website for a list of evaluated polyacrylamide (PAMS) products for use in North Carolina: b. Does this facility overflow only during rainfall events exceeding the 10-yr, 24-hr rainfall event? ❑ No ❑ Yes 29) Are wastewater treatment facilities (including recycle systems) planned in the 100-year flood plain? X No ❑ Yes 30) Is your facility washing mined materials? ❑ No X Yes If Yes, are you discharging this water? NO wash water is contained on site and recycled Page 5 of 8 SWU-NCG02-NOI Last revised 9I5/2012 NCG020000 N.O.I. Other: 31) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? X No ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? X No ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of hazardous waste? X No ❑ Yes d) If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport / disposal vendor: Vendor address: 32) Is your facility providing appropriate secondary containment for bulk storage of liquid materials? See permit text for secondary containment requirements. X No Bulk storage of fuels on site is NOT planned. ❑ Yes 33) Does your site have an active landfill within the mining permit boundary? X No ❑ Yes If yes, specify type: ❑ LCID ❑ Final Checklist: This application will be returned as incomplete unless all of the following items have been included and initialed for. Please show that the following required information has been included by initialing in each space below. X Fee of $100 made payable to NCDENR. X Completed application and all supporting documents. X Copy of the valid approved mining permit (MP) for the facility or indication of MP application status. X Copy of a county map or other general location map that shows the mining site and nearest major roads. X Copy of USGS topographic map showing the mining site and surrounding areas, or other map that clearly shows site location in relation to nearby streams, wetlands, and other waters, etc. X 2 copies of large-scale (minimum 24" x 36") site plan with topographical lines with all outfalls, applicable buffers and wetlands clearly delineated, and 100-year flood plain line if applicable. A copy of your DEMLR mining permit. NA A copy of your US Army Corps -approved wetland delineation if you marked "yes" to question 23 above. _ A line drawing of the water flow through the facility. A pictorial description of the nature and amount of any sources of water and any collection and treatment measures. NA If mine site is in one of the 20 Coastal Counties: • Applicant has checked with the appropriate regional office to verify the need for a Coastal State Stormwater permit. Regional Office Contact: Page 6 of 8 SWU-NCG02-NOI Last revised 9/5/2012 NCG020000 N.O.I. • Applicant has included a detailed list of impervious surface areas and percentages, sub -drainage areas and total drainage area. _ If the mine is dewatering and near wetlands, or may otherwise impact surface waters or groundwater, include the following and contact your local regional office about a Pumping O&M Plan (see below for contact information). You may be required to provide an approved Pumping O&M plan prior to NCG02 issuance. _2 copies of detailed Full Size Plans (at least 24" x 36") delineating areas on the plans and listinq acreage (including: wetlands, ditches, well -placements, pits, borrow areas, overburden storage, stormwater controls/BMPs, vehicle maintenance areas, settling basins, product process (such as screening, stockpiles, waste piles), total drainage area, impervious surface percentages (if state sw programs apply), applicable buffers, and access and/or haul roads). Pump dewatering size and information on its specifications. _Well information (design, depths, maintenance). _Physical monitoring for the wetlands areas. _Settling pond sizing information, if applicable. _Level spreader design, if applicable. _Details about dewatering method. _Cone of influence calculations. _Description of measures to prevent erosion and flooding. _Description & information about 401/404 permits that have been obtained. _Copy of US Army Corps of Engineers wetland delineations or approved wetland delineation (if applicable). _I have contacted my local regional office about a Pumping O&M Plan. Regional Office Contact: Date contacted: -OR- X I will not any impact nearby wetlands, surface waters or groundwater by dewatering. Certification: North Carolina General Statute 143-215.6 b (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the [Environmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). 33) Signatory Requirements (per 40 CFR 122.22) All applications, reports, or information submitted to the Director shall be signed and certified. a. All notices of intent to be covered under this General Permit shall be signed as follows: (1) For a corporation: by a responsible corporate officer. For the purpose of this permit, a responsible corporate officer means: (a) a president, secretary, treasurer or vice president of the corporation in charge of a principal business function, or any other person who performs similar policy or decision making functions for the corporation, or (b) the manager of one or more manufacturing production or operating facilities employing more than 250 persons or having gross annual sales or expenditures exceeding 25 million (in second quarter 1980 dollars), if authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures. (2) For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or (3) For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official. I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I agree to abide by the following as a part of coverage under this General Permit: 1. 1 agree to abide by the approved Mining Permit for this mining activity. (A copy of the valid mining permit must be attached to this request. Page 7 of 6 SWU-NCG02-NOI Last revised 9/5/2012 NCG020000 N.O.I. 2. 1 agree to not discharge any sanitary wastewater from this mining activity except under the provisions of another NPDES permit specifically issued therefore. 3. 1 agree that bulk storage of petroleum products and other chemicals shall have adequate protection so as to contain all spills on the site. 4. 1 agree that solid wastes will be disposed of in accordance with N.C. statutes and rules governing solid waste disposal. 5. 1 agree that maintenance activities for vehicles and heavy equipment will be performed so as to not result in contamination of the surface or ground waters. I agree to abide by the provisions as listed above and recognize that the provisions are to be considered as enforceable requirements of the General Permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: Bobby A. Branch Title: Notice of Intent must be accompanied by a check or money order for $100.00 mad4fpayable to NCDENR. Mail the entire package to: Stormwater and General Permits Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Note The submission of this document does not guarantee the issuance of an NPDES permit. For questions, please contact the DWQ Regional Office for your area. DWQ Regional Office Contact Information: Asheville Office ...... (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ...(252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office ......... (919) 807-6300 Page 8 of 8 SWU-NCG02-N01 Last revised 9l512012 SITE c LOCATION MAP SCALE: NTS 5' �''~ GEOLOGICAL SURVEY GOLDSTON QUAD Sheet PATTERSON EXPLORATION SERVICES February 17, 2016 Larry W. Wade, P.E. NCDENR DEMLR 512 N. Salisbury Street Raleigh, NC 27604 P.O. BOX 3008 - SANFORD, N.C. 27331-3008 - (919) 774-3770 FAX: (919) 774-3510 RFrF7'11/7,7 ) FEB ? 3 2016 DENR-LAND QUALITY STORMWArER PERMIT) ING RE: NPDES Permit Application — Winding Creeks Quarry Larry, We are submitting this application on behalf of Winding Creek Holdings, LLC. Please find attached two copies of the above referenced permit application, two copies of the mine permit application drawing C-4, two general location maps, portion of USGS topographic map showing location, two DWQ stream "Buffer Determination" and a check for the $100.00 permit fee. We will forward the stream determination when we receive it from DWR. If you need anything else, or have any questions please contact me. Thanks, O.F. "R s" Patterson, III, P.G., C.P.G. PA SON EXPLORATION SERVICES 5225 PATTERSON EXPLORATION SERVICES, INC. GEOLOGICAL & GEOPHYSICAL EXPLORATION PO BOX 3008 - (919) 774-3770 SANFORD, NC 27331-3008 PAY TO THE A /` ORDER OF R.1 o--_ 66-456/531 DATE 7 $ /DO, DO DOLLARS 8.,.... FIRST [BANI(hc�-,o �o g98 PATfERSON EXPLORATION SERVICES, INC. VOID A 60 j I MWORD. NORTH GROUNA 37330 FOR .. IMA ©PA. Division of Water Quality / Surface Water Protection NCDENR National Pollutant Discharge Elimination System NyT, [iO OV•Fr✓F.rvr OF Ervviacxr+ervT vlD Nnwu R[w.w[[s NCG020000 NOTICE OF INTENT FOR AGENCY USF ONLY Date Rm6M Y. Monlh Day Certificate of Covcrugc N C G 0 2 Check d A out t 11=w A.i rcd to K)AAlt National Pollutant Discharge Elimination System application for coverage under General Permit NCG020000: STORMWATER DISCHARGES associated with activities classified as: tZ ry� ryry ��QQ SIC (Standard Industrial Classification) Code - 14XX Mineral Mining Industry (except of&9ctHeti I'91%) The following activities are also included: DENR•LAND QUALITY STORMWATER PERMIT ZING Active or inactive mining operations (including borrow pits except for NCDOT borrow pits) that discharge stormwater contaminated with or that has come in contact with, any overburden, raw material, intermediate products, finished products, byproducts or waste products located on the site of such operations; Stormwater from vehicle maintenance activities at mining operations; Overflow from facilities that recycle process wastewater; and/or Mine dewatering (wastewater) The following activities are specifically excluded from coverage under this General Permit: Stormwater discharges associated with peat mining, coal mining, and metal mining, Stormwater discharges from mining operations which are intermixed on site with stormwater from asphalt operations and/or concrete operations; Stormwater discharges associated with oil and gas extraction operations; and Stormwater discharges associated with tourist gem mines NCDOT borrow pits are covered under NCS000150 The following discharges are covered by NPDES general permit NCG520000 instead of NCG020000: Point source discharges of stormwater and wastewater from in -stream sand mining operations (i.e., sand dredging or dipping operations). Please contact the NPDES Wastewater Point -Source Group for more information on coverage under this Please print or tvoe all entries in this application form 1) Mailing address of ownerloperator (official address to which all permit correspondence will be mailed): Legal Owner Name Winding Creek Holdings LLC (Attach the most recent Annual Report to the NC Secretary of State showing the current legal name of the corporation or entity. Alternatively this permit can be given to an individual or government authority. This name must be the same name as appears on the Division of Land Resources' Mining Permit.) Signee's Name (as signed for in permit signature at bottom) Bobby A. Branch Street Address P.O. Box 61 City Gulf State NC ZIP Code 27256 Telephone No. 919-708-8465 Email redmud(dwindstream.net Alternate Contact Name Russ Patterson _ Email (if different) russ(&Pattersonexploration.com Alternate Contact Telephone (if different) 919-774-3770 Page 1 of 8 SWU-NCG02-NOI Last revised 9/5/2012 NCG020000 N.O.I. 2) Location of facility producing discharge: Facility Name Winding Creeks Quarry Facility Street Address US Highway 421 Facility City Bear Creek Facility County Chatham Facility Contact Bobby A. Branch Telephone No. 919-708-8465 Fax: no fax Contact E-mail redmud(rDwindstream.net 3) Physical Location Information: State NC ZIP Code 27207 Please provide a narrative description of how to get to the facility (use street names, state road numbers, and distance and direction from a roadway intersection). SE of the intersection of US 421 and NC 902, near Roscoe Road Oust east of Bear Creek, NC. Center of site coords given below 4) Latitude 350 37' 08.58" N Longitude 0790 22' 48.23" W (degrees, minutes, seconds) Permits: 5) This NPDES Permit Application applies to which of the following: X New or Proposed Facility ❑ Existing 6) Standard Industrial Classification: Date operation is to begin: Mid 2016 Date began mining: Provide the 4 digit Standard Industrial Classification Code (SIC Code) that describes the primary industrial activity at this facility SIC Code: 14 2 3 7) Provide a narrative description of the types of minerals mined at this facility: Metagraywacke will be mined to produce construction aggregate. 8) Is this mine an inactive mine site? X No ❑ Yes If yes, do you posses an "Inactive Renewal" from DEMLR and notified the DWQ Regional Office or have you certified to the DWQ that the site has been stabilized? ❑ No ❑ Yes 9) Does this facility already have a valid Mining Permit from the Division of Energy, Mineral and Land Resources (DEMLR) [formerly DLR]? X No If No, please indicate the status of the Mining Permit application: Permit has been submitted ❑ Yes If yes, please provide the Mining Permit number: Please also provide a copy of your DEMLR Mining Permit with this DWQ application. Note: DWQ cannot issue a COC for the NCG020000 General Permit until a Mining Permit is issued or renewed by the DEMLR. 10) Does this facility have any other NPDES permits? X No ❑ Yes If yes, list the permit numbers for all current NPDES permits for this facility: Page 2 of 8 SWU-NCG02-NOI Last revised 9/5/2012 NCG020000 N.O.I. 11) Are you applying for a mining permit in the same location as a previously permitted mine? X No ❑ Yes If yes, specify permit number and name if known: 12) Does this facility have any Non -Discharge permits (ex: recycle permits)? X No ❑ Yes If yes, list the permit numbers for all current Non -Discharge permits for this facility: 13) Does total area of this mine site include ready -mix and asphalt areas? X No ❑ Yes If yes, do they have DWQ stormwater permits (if owned by the same company)? ❑ No ❑ Yes (provide permit number ) If not owned by the same company, who is the owner? 14) Will this mining operation precede development activities at this site? X No ❑ Yes 16) Is this mine located within one of the 20 Coastal Counties and will it add more than 10,000 ft' of impervious surface? X No ❑ Yes If yes, you may be required to apply for an additional state stormwater permit. Check with your local Regional Office. See contact information and checklist below. 16) Is this mine located the Neuse, Tar -Pamlico, or Catawba River Basins, or the Randleman or Jordan Water supply Watersheds? X No ❑ Yes If yes, what size stream buffers are included on site? ft. Please show buffers in site plans. If yes, please include information and plans showing diffuse flow through buffers as required. Discharge Points, Receiving Waters & Wetlands: 17) Receiving waters: What is the name of the body or bodies of water (creek, stream, river, lake, etc.) that the facility stormwater and/or wastewater discharges end up in? Tributary (intermittent) of Bear Creek If the site stormwater discharges to a separate storm sewer system, name the operator of the separate storm sewer system (e.g. City of Raleigh municipal storm sewer). NA Receiving water classification (if known): Note: Discharge of industrial wastewater to receiving waters classified as WS-11 to WS-V, or SA, must be approved by the Div. of Water Resources, or Div. of Marine Fisheries. If DWR or DMF does not approve, coverage under NCG020000 cannot be granted. No new discharges of wastewater are permitted in receiving waters classified as WS-1 or freshwater ORW. Wastewater discharges to Saltwater ORW will not be approved under the NCG02 General Permit. 18) If your facility has wastewater discharges and they are to HWQ and/or PNA waters (Primary Nursery Areas) waters, what is the proposed flow rate? NA (See http'//www.ncdmf.net/maps/FNA maps/index.html, for map) Page 3 of 8 SWU-NCG02-NOI Last revised 9/5/2012 NCG020000 N.O.I. 19) Discharge Points: Number of discharge points (ditches, pipes, channels, etc. that convey discharges from the property): Onsite: Stormwater: 5 _ Mine dewatering: 1 Process Wastewater Overflow: Offsite: Stormwater: Mine dewatering: Process Wastewater Overflow: Discharge points should be clearly marked on the submitted site plan. Please provide short narrative description of discharges: Site has two intermittent streams (tributaries of Bear Creek) that borders the east & west sides of the site. Most drainage will eventually make it to these streams. Storm water and pit water will be directed to the sediment basins and recycled for process water. Except during initial construction activities and maior storm events, most runoff will be used Make up process water will be from a planned well to be constructed on the plant site a) Is your mine dewatering and discharging? (Answer only if you are dewatering) ❑ No ❑ Yes If yes, where to? _ Surface Waters and/or Wetlands (on -site or off -site) Other (on -site or off -site) Describe: b) Are you dewatering but not discharging? (Answer only if you are dewatering) ❑ No XYeSIf Yes, please explain how you are dewatering, and where that water will be directed: When mining starts and dewatering is necessary, mine water will be directed to Sediment Basin #6 to be recycled 20) Will mining operations require dewatering near wetlands or impact any stream, groundwater, or wetlands? X No ❑ Yes Note: Wetlands must be CLEARLY DELINEATED on the site plan. Mine dewatering activities that have the potential to drain wetlands or otherwise impact surface water or groundwater MUST develop and implement a Pumping Operation and Monitoring (O&M) Plan that has been approved by the Division. For sites that may drain wetlands — approval of a Pumping O&M plan may be required prior to coverage under this general permit. The Pumping O&M Plan should be submitted to the appropriate Regional Office and must be approved prior to operation. The plan shall include, but is not limited to: (1) Groundwater monitoring strategies to demonstrate the effect of pumping and to establish any pumping regime necessary to reduce impacts, and (2) Detailed plans to maintain surrounding hydrology and respective monitoring to demonstrate compliance. See checklist at end of document. Contact your local Regional Office for questions specific to your mine. 21) If you are dewatering, are there wetlands or surface waters within 400' of the mine pit perimeter? No Within 400' an intermittent tributary of Bear Creek X Yes If yes, what distance are they from the mine pit perimeter? 100-380 feet. 22) Have you been required to obtain a 404/401 Certification permits? X No ❑ Yes If yes, please briefly describe below (include information such a required mitigation, BMPs, setbacks, and/or O&M plans for on or off -site wetlands or other pertinent information). Attach other sheets as necessary. Page 4 of 8 SWU-NCG02-NOI Last revised 9/5/2012 NCG020000 N.O.I. 23) Have you been required to obtain a wetland delineation certified by the US Army Corps of Engineers? X No ❑ Yes If yes, please attach to application submission. Stormwater BMPs: 24) Does this facility employ any best management practices for stormwater control? ❑ No X Yes If yes, please briefly describe: Sediment Traps and Basins are constructed at discharge points Disturbed areas are reseeded where practible. See Mine Map B Plans for Details 25) Does this facility have a Stormwater Pollution Prevention Plan? X No ❑ Yes If yes, when was it implemented? 26) Will vehicle maintenance activities occur at this facility? X No ❑ Yes Wastewater Treatment Facilities: 27) Will mine dewatering discharges occur? X No ❑ Yes 28) Will discharges of overflows from process wastewater treatment systems occur? X No ❑ Yes If yes, a. Does this facility employ chemical additives to flocculate suspended solids? X No ❑ Yes If yes, please state the name, manufacturer and the quantity of average daily usage of the chemical additive Please see our website for a list of evaluated polyacrylamide (PAMS) products for use in North Carolina: b. Does this facility overflow only during rainfall events exceeding the 10-yr, 24-hr rainfall event? ❑ No ❑ Yes 29) Are wastewater treatment facilities (including recycle systems) planned in the 100-year flood plain? X No ❑ Yes 30) Is your facility washing mined materials? ❑ No X Yes If Yes, are you discharging this water? NO wash water is contained on site and recycled Page 5 of 8 SWU-NCG02-NOI Last revised 9/5/2012 NCG020000 N.0.1. Other: 31) Hazardous Waste: a) Is this facility a Hazardous Waste Treatment, Storage, or Disposal Facility? X No ❑ Yes b) Is this facility a Small Quantity Generator (less than 1000 kg. of hazardous waste generated per month) of hazardous waste? X No ❑ Yes c) Is this facility a Large Quantity Generator (1000 kg. or more of hazardous waste generated per month) of hazardous waste? X No ❑ Yes d) If you answered yes to questions b. or c., please provide the following information: Type(s) of waste: How is material stored: Where is material stored: How many disposal shipments per year: Name of transport / disposal vendor:_ Vendor address: 32) Is your facility providing appropriate secondary containment for bulk storage of liquid materials? See permit text for secondary containment requirements. X No Bulk storage of fuels on site is NOT planned. ❑ Yes 33) Does your site have an active landfill within the mining permit boundary? X No ❑ Yes If yes, specify type: ❑ LCID ❑ Final Checklist: This application will be returned as incomplete unless all of the following items have been included and initialed for. Please show that the following required information has been included by initialing in each space below. X Fee of $100 made payable to NCDENR. X Completed application and all supporting documents. X Copy of the valid approved mining permit (MP) for the facility or indication of MP application status. X Copy of a county map or other general location map that shows the mining site and nearest major roads. X Copy of USGS topographic map showing the mining site and surrounding areas, or other map that clearly shows site location in relation to nearby streams, wetlands, and other waters, etc. X 2 copies of large-scale (minimum 24" x 36") site plan with topographical lines with all outfalls, applicable buffers and wetlands clearly delineated, and 100-year flood plain line if applicable. _ A copy of your DEMLR mining permit. NA A copy of your US Army Corps -approved wetland delineation if you marked "yes" to question 23 above. A line drawing of the water flow through the facility. A pictorial description of the nature and amount of any sources of water and any collection and treatment measures. NA If mine site is in one of the 20 Coastal Counties: • Applicant has checked with the appropriate regional office to verify the need for a Coastal State Stormwater permit. Regional Office Contact: Page 6 of 8 SWU-NCG02-NCII Last revised 9/5/2072 NCG020000 N.O.I. • Applicant has included a detailed list of impervious surface areas and percentages, sub -drainage areas and total drainage area. If the mine is dewatering and near wetlands, or may otherwise impact surface waters or groundwater, include the following and contact your local regional office about a Pumping O&M Plan (see below for contact information). You may be required to provide an approved Pumping O&M plan priorto NCG02 issuance. _2 copies of detailed Full Size Plans (at least 24" x 36") delineating areas on the plans and listing acreage (including: wetlands, ditches, well -placements, pits, borrow areas, overburden storage, stormwater controls/BMPs, vehicle maintenance areas, settling basins, product process (such as screening, stockpiles, waste piles), total drainage area, impervious surface percentages (if state sw programs apply), applicable buffers, and access and/or haul roads). Pump dewatering size and information on its specifications. _Well information (design, depths, maintenance). _Physical monitoring for the wetlands areas. _Settling pond sizing information, if applicable. _Level spreader design, if applicable. _Details about dewatering method. _Cone of influence calculations. _Description of measures to prevent erosion and flooding. _Description & information about 401/404 permits that have been obtained. _Copy of US Army Corps of Engineers wetland delineations or approved wetland delineation (if applicable). _I have contacted my local regional office about a Pumping O&M Plan. Renional Office Contact: . Date contacted: •OR- X I will not any impact nearby wetlands, surface waters or groundwater by dewatering. Certification: North Carolina General Statute 143-215.6 b (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan, or other document filed or required to be maintained under this Article or a rule implementing this Article; or who knowingly makes a false statement of a material fact in a rulemaking proceeding or contested case under this Article; or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under this Article or rules of the (Environmental Management] Commission implementing this Article shall be guilty of a Class 2 misdemeanor which may include a fine not to exceed ten thousand dollars ($10,000). 33) Signatory Requirements (per 40 CFR 122.22) All applications, reports, or information submitted to the Director shall be signed and certified. a. All notices of intent to be covered under this General Permit shall be signed as follows: (1) For a corporation: by a responsible corporate officer. For the purpose of this permit, a responsible corporate officer means: (a) a president, secretary, treasurer or vice president of the corporation in charge of a principal business function, or any other person who performs similar policy or decision making functions for the corporation, or (b) the manager of one or more manufacturing production or operating facilities employing more than 250 persons or having gross annual sales or expenditures exceeding 25 million (in second quarter 1980 dollars), if authority to sign documents has been assigned or delegated to the manager in accordance with corporate procedures. (2) For a partnership or sole proprietorship: by a general partner or the proprietor, respectively; or (3) For a municipality, state, federal, or other public agency: by either a principal executive officer or ranking elected official. I hereby request coverage under the referenced General Permit. I understand that coverage under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I agree to abide by the following as a part of coverage under this General Permit: 1. I agree to abide by the approved Mining Permit for this mining activity. (A copy of the valid mining permit must be attached to this request. Page 7 of 8 SWU-NCG02-NOI Last revised 9/5/2012 NCG020000 N.O.I. 2. 1 agree to not discharge any sanitary wastewater from this mining activity except under the provisions of another NPDES permit specifically issued therefore. 3. 1 agree that bulk storage of petroleum products and other chemicals shall have adequate protection so as to contain all spills on the site. 4. 1 agree that solid wastes will be disposed of in accordance with N.C. statutes and rules governing solid waste disposal. 5. 1 agree that maintenance activities for vehicles and heavy equipment will be performed so as to not result in contamination of the surface or ground waters. I agree to abide by the provisions as listed above and recognize that the provisions are to be considered as enforceable requirements of the General Permit. I certify that I am familiar with the information contained in this application and that to the best of my knowledge and belief such information is true, complete, and accurate. Printed Name of Person Signing: Bobby A. Branch Title: Notice of Intent must be accompanied by a check or money order for $100.00 madcrpayable to NCDENR. Mail the entire package to: Stormwater and General Permits Unit Division of Water Quality 1617 Mail Service Center Raleigh, North Carolina 27699-1617 Note The submission of this document does not guarantee the issuance of an NPDES permit. For questions please contact the DWQ Regional Office for your area. DWQ Regional Office Contact Information: Asheville Office ...... (828) 296-4500 Fayetteville Office ... (910) 433-3300 Mooresville Office ... (704) 663-1699 Raleigh Office ........ (919) 791-4200 Washington Office ...(252) 946-6481 Wilmington Office ... (910) 796-7215 Winston-Salem ...... (336) 771-5000 Central Office .........(919) 807-6300 Page 8 of 8 SWU-NCG02-NOI Last revised 9/5/2012 ' / ROSCOELi ROADi SITE �'Ap � I L I LOCATION MAP € SCALE: NTS 79' 15 ° 37'30L m/3=6 N. GEOLOGICAL SURVEY GOLDSTON QUAD Sheet 20% 651 NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor August 26, 2015 Rex Hester 367 Roscoe Rd. Bear Creek, NC 27207 Determination Type: I Buffer Call I Isolated or EIP Call Donald R. van der Vaart Secretary Subject: Buffer Determination NBRRO#15-227 Chatham County ❑ Neuse (15A NCAC 2B .0233) ❑ Tar -Pamlico (15A NCAC 2B .0259) ® Ephemeral/Intermittent/Perennial Determination ❑ Isolated Wetland Determination ❑ Jordan (15A NCAC 2B .0267) Project Name: Hester Property Location/Directions: Property is located at 367 Roscoe rd Bear Creek, Chatham County, NC Subject Stream: _Hester Determination Date: July 31, 2015 Staff: James Graham Feature /Flag E/I/P* Start@ Stop@ Soil urve USGS Topo A I throughout throughout X B P throughout throughout X C E throughout throughout X D 1 Approx. to -cation on maps throughout X X E I Approx. location on maps Confluence of D X F E X G F X GI I Pond outfall1, Pond outfall 2 To Pond 2, throughout X X H F X ro Carolina aturally North Carolina Division of Water Resources 1628 Mail Service Center Raleigh, NC 27699-1628 Phone (919) 7914200 Internet: vnaw.ncwaterqualdy.or9 Location: 3800 Barrett Drive Raleigh, NC 27609 Fax (919) 788-7159 An Equal Opportunity/Affirmative Action Employer - 50% Recyded/10%Post Consumer Paper Hester Property Wake County August 26, 2015 Page 2 of 2 I I Approx. location throughout X X on maps P throughout throughout X X K I Approx. location Confluence of X on maps B *F/I/P - Ephemeral/Intermittent/Perennial Explanation: The feature(s) listed above has or have been located on the Soil Survey of Wake County, North Carolina or the most recent copy of the USGS Topographic map at a 1:24,000 scale. Each feature that is checked "Not Subject" has been determined not to be a stream or is not present on the property. Features that are checked "Subject" have been located on the property and possess characteristics that qualify it to be a stream. There may be other streams located on your property that do not show up on the maps referenced above but, still may be considered jurisdictional according to the US Army Corps of Engineers and/or to the Division of Water Resources (DWR). This on -site determination shall expire five (5) years from the date of this letter. Landowners or affected parties that dispute a determination made by the DWR or Delegated Local Authority may request a determination by the Director. An appeal request must be made within sixty (60) days of date of this letter or from the date the affected party (including downstream and/or adjacent owners) is notified of this letter. A request for a determination by the Director shall be referred to the Director in writing. If sending via US Postal Service c/o Karen Higgins DWR — 401 & Buffer Permitting Unit 1617 Mail Service Center Raleigh, NC 27699-1617. If sending via delivery service (UPS, Fed Er, etc.) Karen Higgins DWR — 401 & Buffer Permitting Unit 512 N. SalisburyStreet Raleigh, NC 2760. This determination is final and binding unless, as detailed above, you ask for a hearing or appeal within sixty (60) days. The owner/future owners should notify the Division of Water Resources (including any other Local, State, and Federal Agencies) of this decision concerning any future correspondences regarding the subject property (stated above). This project may require a Section 404/401 Permit for the proposed activity. Any inquiries should be directed to the Division of Water Resources (Central Office) at (919)-807-6300, and the US Army Corp of Engineers (Raleigh Regulatory Field Office) at (919)-554-4894. If you have questions regarding this determination, please feel free to contact James Graham at (919) 791 4256. 7R p ectfull l Danny Smith, upervisor Water Quality Regional Operation Section Raleigh Regional Office cc: RRO/SWP File Copy Michael Blakley Drafting and Design Services. Inc. 346 Woolard Rd. Sanford, NC27330 V tt - -y �q .f +tea'_ - is •.x �0 'Si 1 t f3 aY w VIA SON Lg, k�r` _.---'Ssy x n �:3a 3g iXi�;I� �:r F "t a � n t '<,« r, .`—tea, � a i`.' .� cam' .., .�}1! s z -�• w•'• Y 3-0 l 17 {. ! i^ i.. 3 }EIiaE o T1 ii TY y .V.. #ik e �k'T •��] t�x iy M +F ��yyy$4i i2 A. T^Jo science for a cnanging worta rar r5- 3 v? ip 7/ ItIts CONSTRUCTION SEQUENCE MINING ACTIVITY PHASE 1 1. PRIOR TO COMMENCEMENT OF CONSTRUCTION ACTIVITIES CONTACT NCDEQ LAND QUALITY SECTION (919) 7914200. 2. INSTALL CONSTRUCTION ENTRANCE ON hWY 421 PER PLAN. INSTALL SILT FENCE PER PLAN BELOW ALL PERMA E TITEMPORARY DIVERSIONS AND BASINTRAPS W/ SILT FE E OUTLETS LOW 3. I N N N I 1 NC IN AREAS PER PLAN. 4. INSTALL SKIMMER BASIN 91, 2,3 5. STABILIZE AND SEED ALL SLOPES IMMEDIATELY. ONLY CLEAR AS NECESSARY TO INSTALL BASINS. MAINTAIN SILT FENCE AND SILT FENCE OUTLETS DOWN STREAM UNTIL GOOD GROUND COVER IS ESTABLISHED 5. INSTALL TEMPORARY DIVERSIONS # 1,2,3,4,5,6,7,8 PER PLAN. STABILIZE AND SEED ALL SLOPES IMMEDIATELY. ONLY CLEAR AS NECESSARY TO INSTALL DIVERSIONS. MAINTAIN SILT FENCE AND SILT FENCE OUTLETS DOWN STREAM UNTIL TEMPORARY/PERMANENT LINING, AND GOOD GROUND COVER ON FILL SLOPES IS ESTABLISHED. 6. BEGIN CLEARING NECESSARY AREAS TO INSTALL ACCESS ROAD AND PLANT SITE AND REMOVAL OF OVERBURDEN FROM PIT FOR FILL MATERIAL. 7. BEGIN CONSTRUCTING ACCESS ROAD W/ CULVERT 418 PERMANENT DIVERSIONS AND PIT HAUL ROAD ALONG WITH PLANT SITE. MAINTAIN ALL EROSION CONTROL MEASURES WEEKLY AND AFTER ANY STORM EVENTS, 8. ONCE PLANT SITE, SITE ACCESS ROAD (PERMANENT DIVERSIONS CONSTRUCTED), PIT HAUL ROAD AND SCALE HOUSE SITE GRADES ARE MET AND ALL SLOPES STABILIZED AND SEEDED. BEGIN CONSTRUCTING BERMS PER PLAN. MAINTAIN ALL DOWNSTREAM DIVERSIONS AND SILT FENCE UNTIL GOOD GROUND COVER IS ESTABLISHED. 9 INSTALL PERMANENT SKIMMER BASIN #4. STABILIZE AND SEED ALL SLOPES IMMEDIATELY. ONLY CLEAR AS NECESSARY TO INSTALL BASINS. MAINTAIN SILT FENCE AND SILT FENCE OUTLETS DOWN STREAM UNTIL GOOD GROUND COVER IS ESTABLISHED. 10. INSTALL PERMANENT DIVERSIONS #9, 10. MAINTAIN ALL DOWNSTREAM DIVERSIONS AND SILT FENCE UNTIL GOOD GROUND COVER IS ESTABLISHED. 11. ONCE BERMS ARE COMPLETE AROUND PLANT SITE STABILIZE AND SEED. MAINTAIN SILT FENCE UNTIL THIS ACHIEVED, REMOVE TEMPORARY DIVERSIONS #123456. MAINTAIN ALL DOWNSTREAM DIVERSIONS AND SILT FENCE UNTIL GOOD GROUND COVER IS ESTABLISHED. 12. ONCE PLANT SITE AND BERMS ARE CONSTRUCTED BEGIN PLACING OVERBURDEN IN THE OVERBURDEN AREA. MAINTAIN ALL EROSION CONTROL MEASURES WEEKLY AND AFTER ANY STORM EVENTS UNTIL FINAL MAX FILL IS MET. STABILIZE AND SEED ALL SLOPES AND DENUDED AREAS. 13. ONCE GOOD GROUND COVER IS ESTABLISHED AND NO RUTTING OF SLOPES IS OCCURRING REMOVE ALL EROSION CONTROL MEASURES WHILE MAINTAINING SILT FENCE ON DOWNSTREAM SIDE. 14. ONCE THE BERM CONSTRUCTION IS COMPLETE AND PIT EXCAVATION IS BELOW SKIMMER BASINS #1Z, 3AND TEMPORARY DIVERSION#1, 2, 3, 4, 5,6, REMOVE BASINS AND DIVERSION AND MAINTAIN THAT SURFACE RUNOFF STAYS WITHIN THE PIT. 15. DEWATER ALL SKIMMER BASINS AND SEDIMENT TRAPS WITH SILT BAG PER DETAIL. 16. MAINTAIN SILT FENCE AFTER MAJOR RAIN EVENTS. 17. STABILIZE AND SEED ALL DENUDED AREAS IN WHICH WORK WILL NOT RECOMMENCE WITHIN 7 WORKING DAYS OR 14 CALENDAR DAYS. 18. CALL NCDEQ LAND QUALITY SECTION FOR INSPECTION (919) 7914200. PHASE 2 1. BEGIN MINING ACTIVITIES. 2. TEMPORARY SEED OVERBURDEN AREAS THAT WILL BE DENUDED FOR 30 DAYS OR MORE, 3. MAINTAIN ALL EROSION CONTROL DEVICES WEEKLY AND AFTER MAJOR STORM EVENTS. 4. CALL NCDEQ LAND QUALITY SECTION FOR INSPECTION (919) 7914200. 2%SLOPE 2%SLOPE 2%SLOPE SOIL NOTES: 1. ALL DENUDED AREAS LEFT INACTIVE BETWEEN PERIODS OF GRADMFG ACTIVITY SHALL BE TEMPORARILY SEEDED WITH IN 15 WORMOS DAYS OR 30 CALENDAR DAYS, SHICHEVER IS SHORTER. SEE SEEDING SCHEDULE IN DETAMS. 2. OVERBURDEN PILE TO BE CONSTRUCTED AND STABILIZED FROM BOTTOM PER ABOVE DETAIL AS FILLED. ONCE FINAL LIFT IS RUCHED THE LOW ER SLOPES AND BENCHES SHALL BE COMPLETED WEETING THE RECL MATION PLAN). 3. FOR FINAL STABILVATION O F FILL SLO PES. GRADE TO 3:1 SLOPE, COVER WITH TOPSOIL, SEED AND MULCH. DIVERSION DRCHBERM i- SbIL WASTE PILE RECLAMATION (TYP) NTS EROSION CONTROL LEGEND TOP OF BERM SEDIMENT BASIN WIER FFLES ROCK CHECK DAMS - SILT FENCE -" - sr TEMPORARY DIVERSION DITCH D OUTLET PROTECTION I Irtr J-HOOK W/ SILT FENCE OUTLET SILT FENCE OUTLET DISTURBED AREAS TAILINGS/SEDIMENT PONDS 1.5 AC STOCKPILES 3.5 AC OVERBURDEN STOCKPILE 17.2 AC PROCESSING AREA/HAUL ROADS 2.6 AC MINE EXCAVATION 23.9 AC OTHER MISC EXCAVATION 11.0 AC (BERMS, DIVERSIONS, ETC.) ITOTAL AFFECTED AREA 59.7 AC LEGEND ACTIVE PERMIT BOUNDARY EXISTING CONTOUR ------ EXISTING BUFFER AFFECTED AREA ........ CREEK BERM POND 100 FT CONSTRUCTION ENTRANCE t v i 1 PROPS BOUNDAR (TYP) ' 119,2 A \ AFFECT AREA (TYP) Ism AZ-t1- 1 \\478 \ \ T T \ \ X l \ \ i \ i IL 470 T SITE ACCESS ✓ / .., ,_ - / `., _ _ _ SEE SHEET C-5 L PLANIPROFILE /� SILT FENCE (TYP) \\ .: ,',., .. �-- TEMPORARY /; - \ `��' � � o SKIMMER BASIN #5 W1 RISER TOP DIME: x254 \ ` 27 1 \ .. . BOTTOM DIM-- 109 x236 , CHECK DAM (TYP) --- - / - POOL DEPTH=3.0' TOP ELEE "1.5 �� / _- ,., .. BOTTOM EL=435.0 �� \��� / ✓ A -�450- - .E, PRINCIPAL SPILLWAY EL=438.0 v� OVERBURDEN oLPROPosED=es973cF ��Av 17.2 AC }�- \ VOL REQUIRED=58480 CF .Yl, - WEIRL= 24.0' X V r WEIR D=2.0' \ _ - A RIP RAP A T � - / WEIRLINING CLA '� v WEIR STONE D=9" TDkB (TYP) SKIMMER ORFICEEE4.7"44Q RISER SIZE - 52" CMP V BARREL SIZE-36 CMP > l \ TD#6 (TYP) �` A TD#7 (TYP) '\. - / �/,r OUTLET PROTECTION ( BARREL CONCRETE BASE= 7.0 x 7.0 x 1.0 1 A + _ ', La=152.0' ) BAFFLES=3 DIVERSION INLET PROTECTION La=12.0' 446 STONE E; CLASS B RIP RAP D STONE = 1 5 T SON /. STONE O=CLASS A RIP RAP D=1.0 1 \� \ ++ - ++ '� TEMPORARY v ` A _ SKIMMER BASIN 94 / \ / A SILT FENCE OUTLET(TYP) + 446 + // /, ,' _ BASIN LINING• CLASS ARIP RAP A TOP DIM- 80 x 160 1 BOTTOM DIME: 44x 124 - +� �PD#9 (TYP) / //LL POOL DEPTH-6.0' \ +'+ / / TOP EL=442.0 PLANT SITE A\ : A BOTTOM EL=434.0 WEIR ELEE"0.0 4.9 AC VOL PROPOSED= 54768 CF 1 _ L SILT FENCE OUTLET (TYP) A OVERSIZED FOR PLANT OPERATIONS � VOL REQUIRED= 10800 Cr WEIR L-- i WEIR D= 2.0' 2.0' / CHECK DAM (TYP) + + + + +` A - WEIR LINING=CLASS A RIP RAP 'T L \� / i - + ♦ +,+ + y + + + + ,A v WEIR STONED=1.0' +j �, + ': ' V ' �, _. -EMERGENCY SPILLWAY + r OUTLET PROTECTION #2 CONSTRUCT NATURAL GROUND ! CULVERT#2 ++ % YLa=12.0FT 'y` - SKIMMER SIZE=6" _V A TEMPORARY / ' 50 LF 24" RCP @ 1.0% ^+ W=6.0 FT _ - -- SKIMMER ORFICE=3.7" \ ` SILT FENCE TYP) + Y + i/ STONE 0= CLASS B RIPRAP -.. .BAFFLES= 3 SKIMMER BASIN 92 ,! TOP DIM= 74 x 148 \ + / - +« STONE D= 1.0 FT - - _. DIVERSION INLET PROTECTION BOTTOM DIM= 56 x 130 \ TD#4 (TYP) / - \ \ La=12.0' '\ \ +:+ - \ TEMPORARY / POOL DEPTH 30 ' I ,. __ ___ \'" ++ \ \\ �\ \ - SKIMMER BASIN#3 _ W=9.D' + + v / A _ TOP EL= 422.0 V A - ++ \ � + ,+ v ` A v TOP DIME: 82 x 124 STONE O=CLASS A RIP RAP BOTTOM EL=417.0 ` A ' / + / --BOTTOM DIM=44x 106 DEE1.0' L \ WEIR EL=420.0 V A � + POOL DEPTHI \\ VOL PROPOSED=27348 CF v �v 1 �' •1+ ` ++ ' ✓ TOP EL=426.0 V V A v VOL REQUIRED=21960 CF �` t TD96 (TYP) ` - BOTTOM EL=421.0 / - ��. WEIRL=30.0'�\ , I CHECK DAM (TYP) + \ - WEIR EL=424.0 WEIRD 2.0' - + - VOL PROPOSED= 18528 CF \ WEIR LINING=CLASS A RIP RAP / µ \ - - - + \ VOL REQUIRED= 15300 CF - _ t V A WEIR STONE D=1.0' - / +�+ v � + t VA WEIR LEE 21.0 - t V v EMERGENCY SPILLWAY + . A WEIR D=2.0' `� A CONSTRUCT NATURAL GROUND A _ / \ + /" WEIR LINING=CLASS A RIP RAP , - ! \ SKIMMER SIZE 6' , A v " 1 ++ �� / / / WEIR STONED=1.0' ` - - 1 SKIMMER ORFICE 2.6 \ _ - \ \ - � V A A TD#3 (TYP) ++ v � - / / EMERGENCY SPILLWAY- �' BAFFLES=3 V A TD#5 TYP � YR ��T " + -CONSTRUCT NATURAL GROUND _ v DIVERSION INLET PROTECTION L, 'V �A L (, ) + + v SKIMMER SIZE=4" - �- r� La=12.0' V v +++ l SKIMMER ORFICE=2.2"-- i 23. l + a W-6.0 - A A BAFFLES=3 STONE O=CLASS A RIP RAP \ -� A� - `�� A `, � + ', ! 9 AC,+I- A _. - + � DIVERSION INLET PROTECTION \� v , WEV6 01 _ \. �( \) ,l + \ - - (TYP) +� O=CLASS A RIP RAP A CHECK TYP I z V, I1 STONE V SILT FENCE OUTLET TYP * ' + /� + SILT FENCE TYP ( ) /+, ' SILT FENCE OUTLET (TYP) _ + \ T 4-20 +\+• TD#1 (TYP) +t - V - - / VF v IFUTURE\v �v l� v /OVER8URb Ej v / + v v + SKIMMER BASIN #1 W/ RISER - - A ' Q 180 0 160 360 640 + TOP DIM= 85 x 170 � vAA +" ,L�%? ', , 1 BOTTOM DIM=67 x 152 +,+ V0'" \ POOL DEPTH=3.0' _ ++ _ _4� - v ��� VI- TOP EL=403.5 + r i BOTTOM EL=397.0- SCale: 1" = 180' + + + + + + + t PRINCIPAL SPILLWAY EL=400.0 //' V� WEIR EL=401 5 CHANNEL ID CHANNEL SLOPE SIDE SLOPES PROPOSED DIVERSION TABLE CHANNEL DEPTH TEMPORARY LINING PERMANENT LINING LINING DEPTH TD#1 3.0% 3:1 2.0 FT CLASS A RIP RAP CLASS A RIP RAP 1.0R 70#2 8.0 % 31 2.0 FT CLASS 1 RIP RAP CLASS i RIP RAP 1.0 -T 7D93 1.0% 31 2.0 FT STRAW W/ NETTING SERMUDAGRASS - 7D#4 0.8% 3:1 2.0 FT STRAW W/ NETTING BERMUDAGRASS - TDFS 1.0% 3:1 2.0 FT STRAWW/NETTING BERMUDAGRASS - TD#6 5.6 % 3.1 2.0 FT CLASS B RIP RAP CLASS B RIP RAP 1.5 GT TD#7 5.5 % 3:1 2.0 FT CLASS B RIP RAP CLASS B RIP RAP 1.5 =T TD#8 1 A % 3:1 2.0 FT STRAW W/NETTING BERMUDAGRASS PM 1.0% 4:1 2.0 FT STRAW W/ NETTING BERMUDAGRASS - PD#10 1.0% 4:1 2.0 FT STRAW W/NETTING BERMUDAGRASS - VOL PROPOSED= 38951 CF / SILT FENCE OUTLET (TYP) _ VOL REQUIRED=28980 CF WEIR L- 12.0' \ WEIR D=2.0' - _. WEIR LINING=CLASSA RIP RAP / \ v WEIR STONE D-9" �f ' SKIMMER SIZE=6„ ✓ `� OUTLET PROTECTION (BARREL) _ SKIMMER ORFICE=3.0" v� 71 / La=12.0' _ / RISER SIZE =30"CMP W=6.0' BARREL SIZE=24" CMP STONE OE: CLASS B RIP RAP - ---"� CONCRETE BASE 4 0 x 4.0' x 1.0 - i� STONE D= 1.5' V BAFFLES= 3 / _ L � / v Z? RAFTING AND DESIGN SERVICES, INC. 346 WOOLARD ROAD Sanford, North Carolina 27330 (919)499-8759 phone draftinganddesign@ymaii.com Y �� IY3i G<t EM a a CpJTPRCT( PATTERSON EXPLORATION SERVICES P.O. BOX 30D8 SANFORD, NC 27331-3DO8 Z O a H W 09 Ip i� Z V �Z 30 a Z C U) 'a Z_ Z W UJ LLI Ma W REVISIONS AGENCY REVIEW ONLY NOT FOR CONSTRUCTION Scale: 1'=180 Drawn by: DRAFTING AND DESIGN SERVICES, INC. Sheet: Designed by: DRAFTING AND DESIGN SERVICES, INC. Reviewed by: PATTERSON EXPLORATION SERVICES /� c C4 of 16 Project Number: DDS JOB #: 2015-30 PXS JOB #: 010115 Date: JAN 2016 i IS i i u 1 f +