Loading...
HomeMy WebLinkAboutNCG020019_COMPLETE FILE - HISTORICAL_20150608STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. IV C� �-oo' DOC TYPE N� HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ a"15 wA YYYYMMDD Issue date: 12-23-2014 Version number: 01 lf� SAFETY DATA SHEET ArrMaz 1. Identification of the product GHS product identifier FLOMIN FL 4620 Other means of identification Product Code ZP81801 Recommended use of the chemical and restrictions on use Recommended use Cationic Polymer in Solution. Recommended restrictions None known. Suppliers details Company name ArrMaz Address 4800 State Road 60 East Mulberry, FL 33860 Telephone EHS Contact Phone Number 863.578.1221 (US): E-mail MSDSinfo@arrmaz.com Emergency phone number CANUTEC (Canadian (613) 996-6666 Transport.): CHEMTREC (US (800) 424-9300 Transportation): ArrMaz CIA 24-hr Number (863) 578-1206 (US): 2. Hazard identification Classification of the substance or mixture Physical hazards Not classified. Health hazards Not classified. Environmental hazards Not classified. GHS label elements, including precautionary statements Hazard symbols None. Signal word None. Hazard statement Material can be slippery when wet. Precautionary statement Prevention Observe good industrial hygiene practices. Response Wash hands after handling. , Storage Store away from incompatible materials. Disposal Dispose of waste and residues in accordance with local authority requirements. Other hazards which do not None known, result in classification Supplemental information None. 3. Composition/information on ingredients Mixtures CAS number and other Chemical identify Common name(s), synonym(s) unique identifiers Concentration Cationic Polymer in Solution Proprietary 15 - < 40 Other components below reportable levels 20 - < 30 4. First -aid measures Description of necessary first -aid measures Inhalation Move to fresh air. Call a physician if symptoms develop or persist. Material name: FLOMIN FL 4620 SIDS MEXICO Z1081801 1 16 Issue date: 12-23.2014 Version number: 01 Skin contact Eye contact Ingestion Most important symptoms/effects, acute and delayed Indication of Immediate medical attention and special treatment needed General information 5. Fire -fighting measures Suitable extinguishing media Unsuitable extinguishing media Wash off with soap and water. Get medical attention if irritation develops and persists. Rinse with water. Get medical attention if irritation develops and persists. Rinse mouth. Get medical attention if symptoms occur. Do not induce vomiting. Direct contact with eyes may cause temporary irritation. Treat symptomatically. Ensure that medical personnel are aware of the material(s) involved, and take precautions to protect themselves. Water fog. Foam. Dry chemical powder. Carbon dioxide (CO2). Do not use water jet as an extinguisher, as this will spread the fire. Specific hazards arising from During fire, gases hazardous to health may be formed. The addition of water may increase slip the chemical hazard. Special protective actions for Wear suitable protective equipment. firefighters Fire fighting Move containers from fire area if you can do so without risk. equipment/instructions Specific methods Use standard firefighting procedures and consider the hazards of other involved materials. General fire hazards No unusual fire or explosion hazards noted. 6. Accidental release measures Personal precautions, protective equipment and emergency procedures For non -emergency Material can be slippery when wet. Keep unnecessary personnel away. For personal protection, personnel see section 8 of the SIDS. For emergency responders Keep unnecessary personnel away. Use personal protection recommended in Section 8 of the SDS. Environmental precautions Avoid discharge into drains, water courses or onto the ground. Methods and materials for Large Spills: Stop the flow of material, if this is without risk. Dike the spilled material, where this is containment and cleaning up possible. Cover with plastic sheet to prevent spreading. Absorb in vermiculite, dry sand or earth and place into containers. Do not get water on spilled substance or inside containers. Following product recovery, itush area with water. Small Spills: Wipe up with absorbent material (e.g. cloth, fleece). Clean surface thoroughly to remove residual contamination. Do not get water on spilled substance or inside containers. Never return spills to original containers for re -use. For waste disposal, see section 13 of the SIDS. 7. Handling and storage Precautions to ensure safe Observe good industrial hygiene practices. In case of spills, beware of slippery floors and surfaces. handling Do not breathe dustlfume/gas/misVvaporslspray. Provide adequate ventilation. Avoid contact with eyes, skin, and clothing. Conditions for sate storage, Store in original tightly closed container. Store away from incompatible materials (see Section 10 including any incompatibilities of the SDS). Keep away from heat and sources of ignition. Keep material from freezing Keep tightly closed in a dry and cool place. 8. Exposure control slpersonaI protection Control parameters Occupational exposure limits No exposure limits noted for ingredient(s). Biological limit values No biological exposure limits noted for the ingredient(s). Control banding approach Not available. Appropriate engineering Good general ventilation (typically 10 air changes per hour) should be used. Ventilation rates controls should be matched to conditions. If applicable, use process enclosures, local exhaust ventilation, or other engineering controls to maintain airborne levels below recommended exposure limits. If exposure limits have not been established, maintain airborne levels to an acceptable level. Material name: FLOMIN FL 4620 sos MExico ZP81801 216 Issue date: 12-23-2014 Version number: 01 Individual protection measures, such as personal protective equipment Eyelface protection Wear safety glasses with side shields (or goggles). Skin protection Hand protection Wear appropriate chemical resistant gloves. Other Wear suitable protective clothing. Respiratory protection In case of insufficient ventilation, wear suitable respiratory equipment. Thermal hazards Wear appropriate thermal protective clothing, when necessary. General hygiene Always observe good personal hygiene measures, such as washing after handling the material considerations and before eating, drinking, and/or smoking. Routinely wash work clothing and protective equipment to remove contaminants. 9. Physical and chemical properties Appearance Clear to Amber Viscous Liquid. Physical state Liquid. Form Liquid. Color Clear to Amber. Odor Slight Aliphatic. Odor threshold Not available. pH Melting point/freezing point Initial boiling point and boiling range Flash point 5 - 7 (0.5% dispersion in water) 27 °F (-3 °C) Not available. Not available. Evaporation rate Not available. Flammability (solid, gas) Not available. Upper/lower flammability or explosive limits Flammability limit - lower Not available. (°io) Flammability limit - upper Not available. (%) Explosive limit - lower (%) Not available. Explosive limit - upper (%) Not available. Vapor pressure Vapor density Relative density Solubility(ies) Partition coefficient (n-octanol/water) Auto -ignition temperature Decomposition temperature Viscosity Viscosity temperature Other information Density Density temperature 10. Stability and reactivity Reactivity Chemical stability Possibility of hazardous reactions Conditions to avoid Not available. Not available. Not available. Completely miscible in water. Not available. Not available. Not available. 700 - 1000 cP 77 °F (25 °C) 8.51 - 8.85 lb/gal 77 °F (25 °C) The product is stable and non -reactive under normal conditions of use, storage and transport. Material is stable under normal conditions. No dangerous reaction known under conditions of normal use. Contact with incompatible materials. Material name: FLOMIN FL4620 SIDS MEXICO ZP81801 316 Issue date: 12-23-2014 Version number: 01 Incompatible materials Strong oxidizing agents. Iron and Iron salts. Copper. Copper alloys. Aluminum. Steel. Hazardous decomposition Carbon oxides. Nitrogen oxides (NOx). Ammonia. Hydrogen chloride. Irritating and/or toxic fumes products and gases may be emitted upon the products decomposition. 11. Toxicological information Information on likely routes of exposure Inhalation Not classified. May irritate the respiratory system at high concentrations. Skin contact Not classified. May cause temporary skin irritation. May be slippery in contact with skin. Eye contact Not classified. Direct contact with eyes may cause temporary irritation. Ingestion Not classified. Symptoms Direct contact with eyes may cause temporary irritation. Information on toxicological effects Acute toxicity Not classified. Skin corrosionlirritation Not classified. Prolonged skin contact may cause temporary irritation. Serious eye damage/eye Not classified. Direct contact with eyes may cause temporary irritation. irritation Respiratory or skin sensitization Respiratory sensitization Not classified. Skin sensitization Not classified. This product is not expected to cause skin sensitization. Germ cell mutagenicity Not classified. No data available to indicate product or any components present at greater than 0.1 % are mutagenic or genotoxic. Carcinogenicity This product is not considered to be a carcinogen by [ARC, ACGIH, NTP, or OSHA. Reproductive toxicity This product is not expected to cause reproductive or developmental effects. Specific target organ toxicity Not classified. single exposure Specific target organ toxicity - Not classified. repeated exposure Aspiration hazard Not classified. Other information Not available. 12. Ecological information Ecotoxicity The product is not classified as environmentally hazardous. However, this does not exclude the possibility that large or frequent spills can have a harmful or damaging effect on the environment. Persistence and degradability No data is available on the degradability of this product. Bioaccumulative potential No data available. Mobility in soil No data available. Other adverse effects No other adverse environmental effects (e.g. ozone depletion, photochemical ozone creation potential, endocrine disruption, global warming potential) are expected from this component. 13. Disposal considerations Disposal methods Disposal instructions Collect and reclaim or dispose in sealed containers at licensed waste disposal site. Local disposal regulations Dispose in accordance with all applicable regulations. Hazardous waste code The waste code should be assigned in discussion between the user, the producer and the waste disposal company. Waste from residues 1 Dispose of in accordance with local regulations. Empty containers or liners may retain some unused products product residues. This material and its container must be disposed of in a safe manner (see: Disposal instructions). Contaminated packaging Empty containers should be taken to an approved waste handling site for recycling or disposal. Since emptied containers may retain product residue, follow label warnings even after container is emptied. 14. Transport information SCT Not regu)ated as dangerous goods. Material name: FLOMIN FL4620 sIDsMEXlco ZP81801 4/6 Issue date: 12-23-2014 Version number: 01 DOT Not regulated as dangerous goods. ADR Not regulated as dangerous goods. RID Not regulated as dangerous goods. ADN Not regulated as dangerous goods. IATA Not regulated as dangerous goods. IMDG Not regulated as dangerous goods. Transport in bulk according to Not applicable. Annex II of MARPOL 73178 and the IBC Code 15. Regulatory information Safety, health and This safety data sheet was prepared in accordance with the Official Mexican Standard environmental regulations (NOM-018-STPS-2000). specific for the product in question Mexico. Substances subject to reporting for the pollutant release and transfer registry (PRTR) Not listed. International regulations Montreal Protocol Not applicable. Stockholm Convention Not applicable. Rotterdam Convention Not applicable. Kyoto protocol Not applicable. Basel Convention Not applicable. International Inventories Country(s) or region Inventory name On inventory (yeslno)* Australia Australian Inventory of Chemical Substances (AICS) Yes Canada Domestic Substances List (DSL) Yes Canada Non -Domestic Substances List (NDSL) No China Inventory of Existing Chemical Substances in China (IECSC) Yes Europe European Inventory of Existing Commercial Chemical No Substances (EINECS) Europe European List of Notified Chemical Substances (ELINCS) No Japan Inventory of Existing and New Chemical Substances (ENCS) Yes Korea Existing Chemicals List (ECL) Yes New Zealand New Zealand Inventory Yes Philippines Philippine Inventory of Chemicals and Chemical Substances Yes (PICCS) United States & Puerto Rico Toxic Substances Control Act (TSCA) Inventory Yes 'A "Yes" indicates that all components of this product comply with the inventory requirements administered by the governing country(s) A "No" indicates that one or more components of the product are not listed or exempt from listing on the inventory administered by the governing country(s). Material name: FLOMIN FL 4620 sos MEXICO ZP81801 5/6 Issue date: 12-23-2014 Version number: 01 16. Other information List of abbreviations Not available. Disclaimer ArrMaz Products cannot anticipate all conditions under which this information and its product, or the products of other manufacturers in combination with its product, may be used. It is the user's responsibility to ensure safe conditions for handling, storage and disposal of the product, and to assume liability for loss, injury, damage or expense due to improper use. The information provided in this Safety Data Sheet is correct to the best of our knowledge, information and belief at the date of its publication. The information given is designed only as a guidance for safe handling, use, processing, storage, transportation, disposal and release and is not to be considered a warranty or quality specification. The information relates only to the specific material designated and may not be valid for such material used in combination with any other materials or in any process, unless specified in the text. This data sheet contains Product and Company Identification: Product and Company Identification changes from the previous Composition 1 Information on Ingredients: Ingredients version in section(s): Physical & Chemical Properties: Multiple Properties Regulatory Information: United States GHS: Classification Material name: FLOMIN FL 4620 sos MEXICO Z P81801 616 'ii=AMA NCDENR North Carolina Department of Environment and Natural Resources Pat McCrory Governor Ms. BEui'Y JO REDMOND — SECRETARY WADE MOORE EQUIPMENT COMPANY P. O. Box 546 LOUISBURG, NORTH CAROLINA 27549 Dear Permittee: Donald R. van der Vaart Secretary May 8, 2015 Subject: Multimedia Compliance Inspection Fleming Pit Franklin County Department of Environment and Natural Resources staff from the Raleigh Regional Office conducted a multimedia compliance inspection of Fleming Pit on April 23, 2015 for permits and programs administered by the following Divisions: Division of Air Quality Division of Energy, Division of Water Division of Waste Mineral, and Land Resources Management Resources We appreciate your cooperation during the inspection and hope that you have enjoyed the benefit of our initiative to provide a single inspector capable of handling multiple areas of environmental compliance at your facility. The results of each applicable inspection and any associated response actions or necessary corrective measures are detailed in the inspection letters/reports attached to this transmittal sheet. If you have any questions regarding this multimedia inspection or the results of each program inspection, please contact the Raleigh Regional Office at (919) 791-4200 and ask to speak with the appropriate Division staff. Thank you for your cooperation. Copies: DEMLR RRO Files DWR RRO Files NCDENR Raleigh Regional Office 1628 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 3800 Barrett Drive, Raleigh North Carolina 27609 Phone: 919-791.42001 Fax: (919) 788-7159 An Equal Opportunity 1 A(frmahve Action Employer - Made in part with recycled paper North Carolina Department of Environment and Natural Resources, Division of Energy, Mineral, and Land Resources, Land Quality Section MINE INSPECTION REPORT E PERMITTED MINE SITE ❑ UNPERMITTED MINE SITE 1. MINE NAME: Fleminp, Pit _ 2. MINE LOCATION: SR 1600 3. COUNTY: Franklin - 4. RIVER BASIN: Tar -Pamlico 5. CASE: NA 6. OPERATOR: Wade Moore Equip. Co. 7. ADDRESS: PO Box 546 Loulsbure. NC 27549 8. MINING PERMIT #: 35-01 NIA 9. PERMIT EXPIRATION DATE: 8/29/2022 ❑ NIA 10. PERSON(S) CONTACTED AT SITE: Wilbur Moore & Betty Jo Redmond 11. PICTURES? ❑ Yes E No TAKEN BY: 12. TYPE OF INSPECTION: ❑ A. Initial Inspection (Unpermitted Mine Sites) 1..Size of affected land: ac. (attach sketch map) 2. How was this area measured? Measured by: ® B. Routine Inspection (Permitted Mine Sites) C. Follow-up Inspection 13. Date of last inspection: 3/7/2012 14. Any mining since that date? E Yes ❑ No If yes, cite evidence of such mining activity: Ongoing processing of sand and reclamation work along river side of site in particular 15. Was mine operating at time of inspection? ® Yes ❑ No If yes, explain: Maintenance work was underway at plant site 16. Is the mine in compliance with the Operating Conditions of the Permit? ❑ Yes E No ❑ N/A If no, explain: Condition 4(A) — runoff outfall below plant along old access road discharges to an old settling area that has been reclaimed adjacent to the river. Moderate erosion has contributed to minor sediment loss into that area. This outfall needs to be cleaned up and protected with an appropriate sediment trap or other measures, or eliminated, sufficient to prevent a sediment dischage. A_slope drain to the river below the plant also needs protection or elimination. The existing basin at SDO 92 needs to be cleaned out and provided with a fresh stone dam outlet to -protect the culvert discharging from that basin. Condition 5 — No boundaly markings have been provided. Much of the perimeter is established along the river side and SR 1600; however, these areas could be more clearly identified, and the remaining perimeter needs to be marked for clarity in the field. 17. Is the mine in compliance with the Reclamation Conditions of the Permit? E Yes ❑ No ❑ NIA If no, explain: 18. Is there any off -site damage? A. ❑ Yes B. E No C. ❑ None observed If A, describe the type and severity of the damage: If B or C, is there potential for offsite damage? E Yes ❑ No Explain: Soil loss could occur where the outfalls have been observed below the plant adjacent to the river. 19. Corrective measures needed and/or taken: Ground cover articular] aloe the river side looks ve good and overall housekeeping is excellent. Protective measures need improvement_ around the plant site as noted 20. Other recommendations and comments: Basin improvements at SDO#2 will establish a clear sampling location that will be easily accessed. Additional ground cover around the plant/stockpile areas could improve the stormwater runoff . Road ditch at entrance by NCDOT needs attention; will follow-up with NCDOT. 21. Is the Annual Reclamation Report +/- map accurate? ® Yes ❑ No (Explain) ❑ Not Reviewed ❑ NIA Reported affected areas appear consistent with the footprint on the current plans 22. Follow-up inspection needed? E Yes ❑ No Proposed date About 60 days (30-dayponse 23. No. of additional pages of Inspection Report 0 24. Copy of Report sent to operator Yes,5-7-2015 INSPECTED BY: John Rolle, Cory Larsen, Maureen Conner, Ray Williams DATE 4/23/2015 Telephone No: 919-791-4206 Copy to file Copy to operator Copy to Mining Specialist NCDENR North Carolina Department of Environment and Natural Resources. Pat McCrory Governor April 29, 2015 MS. BETTY REDMOND WADE MOORE EQUIPMENT COMPANY P. O. Box 546 LOUISBURG, NORTH CAROL' INA 27549 Subject: NPDES Stormwater Compliance Evaluation Inspection COC Number NCG020019 Fleming Pit Sand Mine NCG020000 General Permit for Mining Activities Franklin County Dear Ms. Redmond: Donald-R, van der Vaart Secretary Staff from the Department of Environment and Natural Resources conducted a stormwater compliance inspection on April 23, 2015 for permit no. NCG020019 as part of a multi -media inspection of your facility. We appreciate the assistance provided by you and Mr. Wilbur Moore during the inspection. Please reference the attached inspection report checklist and summary in addition to the comments provided below. Stormwater is well managed at the facility and was generally found to be in compliance with most permit conditions, however, a number of items do require your attention as follows: 1. The stormwater management plan was completed or last updated in 2006 and requires thorough updating to include all relevant information as required in Part III Section A:3 of the general permit and shall be updated on an annual basis going forward to account for any physical or operational changes at the facility. Two (2) additional stormwater discharge outfalls (SDOs) were identified during the inspection and must be added to the SMP and monitored in accordance with the general permit for qualitative and analytical monitoring. One of the outfalls may be eliminated by filling and grading as discussed onsite. 3. Qualitative monitoring shall be conducted twice per year at all SDOs. Analytical monitoring shall be conducted quarterly during a representative storm event (see Part III p.6 of permit) within the first 30 minutes of discharge through the outfall pipe at all SDOs receiving any dewatering or process wastewater, including truck bed washing, ArrMaz flocculant Flomin FL4620 used in the final settling pond to enhance solids settling performance is not currently approved for use by Division. Please contact the Stormwater Permitting Unit for approval of this product or replace it with one on the enclosed approved PAMS/flocculant list. Division of Water Resources, Raleigh Regional Office, Water Quality Operations Section http://portal.ncdenr.org/web/wq/aps 1628 Mail Service Center, Raleigh, NC 27699-1628 Phone: (919) 791-4200 Location: 3800 Barrett Drive, Raleigh, NC 27609 Fax: (919) 788-7159 An Equal Opportunity 1 Affirmative Action Employer- Made in part by recycled paper April 29, 2015 ' Nagc 2 of 2 Please provide your written response (including implementation schedule) to the above items within 30 days of receipt of this letter. If you have any questions regarding these matters, please contact me at cory.larsen a,nedenr.gov or 919-791-4200. Sincerely, Cory Larsen, E Environmental Engineer Raleigh Regional Office Enclosures: Compliance Inspection Report North Carolina DWR List of Approved PAMS/Floccu]ants cc: RRO/SWP Files Central Files HCD NR North Carolina Department of Environment and Natural Resources Pat McCrory John E. Skvarla, III Governor Secretary North Carolina DWR List of Approved PAMS/Flocculants Updated 11/10/2014 Company Product Maximum Recommended Concentration Applied Polymer System APS 712 59.3 ppm Applied Polymer System APS 730 5.6 ppm Applied Polymer System APS 740 5.2 ppm Applied Polymer System APS 703d ** Applied Polymer System APS 703d#3 ** Applied Polymer System APS 706b ** Applied Polymer System APS 705 27.7 ppm A uamark, Inc AQ100 Land surface application only at 39.7 pprn A uamark, Inc AQ109 Land surface application only at 0.180 /l Ashland Hercules Water Tech Ashland Charge Pac 55 10 m /L Ashland Hercules Water Tech Ashland Zalta MC 9500 10 m /L Cape Fear Consulting PAX-CFC39A 5 pern Cape Fear Consulting CFC-4330 4.5 pprn Carolina H drolo ics HYDROLOC PAM Land surface application only at 3.0 m /l Chemical Solutions, Inc. CS-1234 and/or CS-1234D 500 m /L per 18% solids *(see below)* Green Techniques Soil Defender Land surface application only at 0.008% HaloSource, Inc. GelFloc 2.56 m /L HaloSource, Inc. LBP-2101 500 m /L Hanes Geo Components TerraGuard Granular PAM 3.25m 1L Innovative Turf Solutions EnviroPam 200 mg/L Innovative Turf Solutions Erosion Guard Powder, Erosion Guard Logs/Erosion Guard Flats 200 mg/L Innovative Turf Solutions FLOC 650 m /L Leaner Meaner Greener, Inc L.M.G. Dust Magnet 281 Solution 0.05% Leaner Meaner Greener, Inc L.M.G. Dust Magnet 163 powder 0.5 m /L Leaner Meaner Greener Inc DBP-2100 28.125 m /L Nalco Nalco 8187 -100-PPM NTU GeoScrub 10 13 20 23 34 10 m /L NTU GeoScrub Bubbles 1 m IL Paschal Associates Sales PFR P251 25 ppm Southeastern Laboratories SEL FLOC 6026 7.5 ppm Storm Klear 3% Li ui-Floc .9.4 m /L Terra Novo EarthGuard .000625 mUL Additional information for specific products: • For use and toxicity guidance regarding CS-1234 and/or CS-1234D, please contact Cindy Moore with the DWR Aquatic Toxicology Branch at (919) 743-8442 or at cindy.a.mooreCQncdenr.gov See next page for additional information 1621 Mail Service Center, Raleigh, North Carolina 27699-1621 Location: 4401 Reedy Creek Road, Raleigh, North Carolina 27607 Phone: 919-743-84001 FAX: 919-743-8517 Internet: portal. ncdenr.orghxebtwq/home An Equal Opportunity 1 Affirmative Action Employer Please check for updates to this list online by navigating to the following link: httpa/portal.ncdenr.org/c/document_librarylget file?uuid=0422f500-1781-4818-b46a- db0708dd2f57&groupld=38364 For more information on the use of polymers, please contact Boyd DeVane at (919) 807-6373 or at boyd.devanencdenr.gov . For additional information about toxicity testing requirements, please contact Cindy Moore at (919) 743-8442 or at cindy.a.moore[�ncdenr.gov . A list of laboratories that have been approved by the DWR to perform toxicity testing can be found at: httpalportal.ncdenr.org/c/document library/get file?uuid=97ceb8ed-0454-4a4b-ae0a- 3450fd756661 &groupld=38364 Permit: NCG020019 SOC: County: Franklin Region: Raleigh Compliance -Inspection Report Effective: 01/01/10 Expiration: 12/31/14 Owner: Wade Moore Equipment Company Effective: Expiration: Facility: Wade Moore Equipment Company Fleming Pit Contact Person; Betty J Redmond Title: Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s); Related Permits: Inspection Date: 04/23/2015 EntryTime: 10:OOAM Primary Inspector; Cory Larsen Secondary Inspector(s): Louisburg NC 27549 Phone; 919-496-3794 Certification: Phone: Exit Time: 04:OOPM Phone: 919-807-6300 Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Mining Activities Stormwater Discharge COC Facility Status: ❑ Compliant Not Compliant Question Areas: 0 Storm Water (See attachment summary) Page: 1 Permit: NCG020019 Owner • Facility: Wade Moore Equipment Company Inspection Date: 04/2312015 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: A multi -media pilot program inspection was conducted by Division staff from Water Resources, Energy, Mining and Land Resources, Air Quality, and Solid Waste on April 23, 2015 to evaluation compliance with mining and stormwater permit compliance at the facility. The stormwater inspection results for NCG020019 are presented below. The stormwater pollution prevention plan (SPPP) was reviewed and contained most of the required components however, it has not been updated since 2006 and will need to be amended as necessary and updated thereafter. Qualitative monitoring has not been consistently performed at SDO 1 and SDO 2 on a semi-annual basis. Both outfalls receive process and/or dewatering wastewater and require wastewater analytical monitoring to be performed quarterly. It is currently conducted semi-annually and during periods of no -flow through the outfall (ponds are sampled and analyzed but not the actual discharge) and will need to be sampled properly. Vehicle maintenance is conducted under roof in well -kept areas away from potential stormwater discharge points. Staff inspected SDO 1 and SD02 of which the former was discharging at the time of inspection. Flomin FL 4620 chemical flocculant is dripped into the final settling basin to enhance particle settling. This flocculant is not currently approved by DEMLR and will need to be evaluated or switched to an approved chemical. No evidence of sediment deposition was observed at SDO 1 outfall to Buffalo Creek. SDO 2 discharges down a riprap spillway to the Tar River and was not discharging at the time of inspection but appeared to be stable. Staff suggested some improvements at SD02 pond outlet to facilitate ease of sampling as well as cleanout of solids contained in the pond. The inspection also revealed two (2) unidentified outfall locations, one directly behind the sand screw with a plastic corrugated pipe discharging down the bank to the Tar River, which will require monitoring if not filled and eliminated; and another discharge point flowing to the riparian floodplain near the confluence of Buffalo Creek and Tar River. Staff suggested installation of sediment control measures at this location (sediment basin) and explained that this point would require analytical and qualitative monitoring of discharges. Two large diesel engine pumps were noted and confirmed to be exempt from applicable air quality regulations. The mining inspection results are covered under separate report. No solid waste violations were observed. Page: 2 Permit: NCG020019 Owner - Facility: wade Moore Equipment Company Inspection Date: 0412312015 Inspection Type: Compliance Evaluation Reason for Visit: Routine Stormwater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? E ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? 0 ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ E ❑ # Has the facility evaluated feasible alternatives to current practices? 0 ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? N ❑ ❑ ❑ # Does the Plan include a BMP summary? 0 ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? 0 ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? N ❑ ❑ ❑ # Does the facility provide and document Employee Training? ❑ ❑ ❑ # Does the Plan include a list of Responsible Party(s)? ❑0 ❑ ❑ # Is the Plan reviewed and updated annually? ❑ 0 ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? N ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? ■ ❑ ❑ ❑ Comment: SPPP needs thorough updating Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ❑ 0 ❑ ❑ Comment: Has not been conducted consistently at required frequency. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ 0 ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ 0 ❑ Comment: Analytical monitoring has been conducted but not at required frequency (quarterly). Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? N ❑ ❑ ❑ # Were all outfalls observed during the inspection? 0 ❑ ❑ ❑ # If the facility has representative outfalt status, is it property documented by the Division? ❑ ❑ 0 ❑ # Has the facility evaluated all illicit (non Stormwater) discharges? 0 ❑ ❑ ❑ Comment: Two (2) SDO locations were identified during the inspection that are not currently monitored. Will need to be added. Page: 3 Permit: r11! Owner - Facility: nr Inspection Dato: Inspection Type: Compliance Evaluation Stormwater Pollution Prevention Plan Does the site have a Stormwater Pollution Prevention Plan? # Does the Plan include a General Location (USGS) map? # Does the Plan include a "Narrative Description of Practices"? £c%�P. (�o • Nl. p-, T # Does the Plan include a detailed site map including outfall locations and drainage areas? # Does the Plan include a list of significant spills occurring during the past 3 years? # Has the facility evaluated feasible alternatives to current practices? # Does the facility provide all necessary secondary containment? # Does the Plan include a BMP summary? # Does the Plan include a Spill Prevention and Response Plan (SPRP)? # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? # Does the facility provide and document Employee Training? # Does the Plan include a list of Responsible Party(s)? # Is the Plan reviewed and updated annually? # Does the Plan include a Stormwater Facility Inspection Program? Has the Stormwater Pollution Prevention Plan been implemented? Comment: Qualitative Monitoring Has the facility conducted its Clualitative Monitoring semi-annually? Comment: Analytical Monitoring Has the facility conducted its Analytical monitoring? # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? Comment: Permit and Outfalls # Is a copy of the Permit and the Certificate of Coverage available at the site? # Were all outfalls observed during the inspection? Reason for Visit: Routine # If the facility has representative outfall status, is it properly documented by the Division? # Has the facility evaluated all illicit (non stormwater) discharges? Comment: f-C4VW-L+ B'D❑❑ d❑❑❑ EY0 ❑ ❑ a"D00 ❑❑d❑ Q'❑❑❑ d❑❑❑ Y 0 0 0 Vo 0 0 Gl'❑ ❑ ❑ 51/❑❑❑ 0NrOD ❑ R(❑ ❑ fV!� g/❑❑❑ 01❑❑❑ Yes No NA NE ❑0U11 Yes No NA NE `2- .SOUf FL 1� t I t I [Manor K. Ocker S l I I Donlols t DMIGIS Fame. Inc. W r. M F. FVw Gl LAND QUALITY SECTION The m Ron" UnnoM. N w rmwr ' + wnr b-4"• ten r,' w,a.ere.e �r.. rnt h 1'..100'. rWyW p.p.�N F.�/11 M M111 MI..lC.� fa.L �M .CMON we xr .d. F.mn mow« ..s LL 4=r� ra.or� �.';a2dk7alytical' www.pecelabs.com i Wilbur Moore Wade Moore Equipment Company PO Box 546 Louisburg, NC 27549 1'1C�r0 2-001 Laboratory Report Project: STORMWATER SAMPLING 06/02/15 Pace Project No.: 92252409 - Sample: SITE 1 GP Lab ID: 92252409001 Collected: 06/02/15 12:45 Parameters Turbidity Total Settleable Solids Total Suspended Solids pH at 25 Degrees C Sample: SITE 2 GP Parameters Turbidity Total Settleable Solids Total Suspended Solids pH at 25 Degrees C ANALYTE QUALIFIERS Results Units Report Limit Analyzed 5.8 NTU 0.50 06/0311513:40 ND mUUhr 0,10 06103/1513:33 6.9 mg/L 3.3 06/03/1511:46 7.1 Sid. Units 1.0 06/05/15 14:30 Lab 10: 92252409002 Collected: 06/02/15 12,30 Results Units Report Limit Analyzed 10.9 NTU 0.50 06103/1513:40 ND mLIL1hr 0.10 06103l1513:32 ND mg/L 12.5 06/0311511:46 6.8 Std. Units 1.0 06/05/15 14:30 H6 Analysis initiated outside of the 15 minute EPA recommended holding time. Reviewed by: Brittany Gibson for Terri Page terri,page@pacelabs.com Raleigh Certification IDs 6701 Conference Drive, Raleigh, NC 27607 North Carolina Wastewater Certification #: 67 Eden Certification 1Ds 205 East Meadow Road Suite A, Eden. NC 27288 North Carolina Drinking Water Certification #: 37738 PacoAnalytical Services, Inc, 6701 Conference Drive Raleigh, NC 27607 (919)834-4984 Page 1 of 1 Report Date: 06/08/2015 Date Received: 06/02/2015 Matrix: Water Qualifiers H6 Matrix: Water Qualifiers H6 North Carolina Bioassay Certification #: 16 North Carolina Drinking Water Certifcatlon #: 37731 North Carolina Wastewater Certification #: 633 VirginiaNELAP Certification #:460025 Page 1 of 3 F ?CmferenGe eAnalytical www.�acelabs.com 67Drive, Raleigh, NC 27607 ph: (919) 834.4984. fax: (919) 834-6497 NCVVW Cert#67, NCDW Cert#37731 Report Resui� Company: Address: _ Gil � Chain of Custody Bill T . n Attn: v nY112 11Lwr�!:= Phone: 911 — `f 4 4o — 37 9 Fax: —11 9 -- q- Z �9 Sampled by (signature): To: LJU'k w.o. # o 5 ` 011 Project Reference: Project Number: Purchase Order #: * Standard Report Delivery ❑ Rush Report Delivery (w/surcharge) "Rush profects are subfoot 10 prior approval by the laboratory Requested Due Date: 13 +. SO. Pit It- ti tQ +� �t 1` �� •So �_ , l�tt �ss , W1"b�l l I`lI� Reif ished by (sign tur) R by (signature) Date Time Relinquis d by signature) Received by (signature) Date Time Relinquished by (signature) Received by {signature) Date Time Receipt Conditions (L�t� U,�p Only) Q 4#2°C II Temp: °C Res. Chlorine: ❑ Absent ❑ Present ❑ n/a Acid preserv. <2? 0 Yes ❑ No ❑ n/a Base preserv. >12? 0 Yes © No 0Page 2 of 3 U 'aceAnafytica!" Document Name: Sample Condition Upon Document Revised: May 15, 2015 Recei t SCUR Page 1 of 2' Document NO.:- Issuing Authorities: r F-RAL-CS-001-rev.03 Pace Raleigh Qualit Office "Page 2 of 2, is for Internal Use Only Client Name: Courier (Circle): Fed Ex UPS USPS Client Commercial Pace Other Custody Seal on Cooler/Box Present: ❑ yes no Seals intact: yes ❑ no Packing Material: ❑ Bubble Wrap Bubble Bags /None Other Circiq Thermometer Used: IR Gun 122065387T a of Ice. Wet Blue Node Samples on ice, cooling process has begun IR Gun Bac • 22065371 Temp Correction Factor: Add I ubtract Corrected Cooler Temp.: C Temp should be above freezing to 6'C , D C t3iologica! Tissue is Frazee Yes Nu NIA Comments: Date and Initials of parson examining chock: �! Pr©eg tl n� (� i 7 Chain of Custody Present: Yes ❑No DNIA 1 r ' Chain of Custody Filled Out:-- Yes ❑No •❑NIA 2: Chain of Custody Relinquished: Yes ONO .. ❑N1A 3. Sampler name & Signature on COC: Yea ❑No._ ❑N1A. 4• .. . Samples Arrived within Hold Time: Yss ❑No ❑N1A 5. Short Hold Time Analysts <72hr : Yes El No '❑N1A 6. Uu Rush Turn Around Time Requested- ❑Yes KNo ❑NIA 7. C\ A (1d i ' a Sufficient Volume: as ©No ❑N!A B, Correct Containers Used. -Pace Corit6i6ers Used: 'I-45lYes ❑No ❑NIA /byes ❑No ❑NIA 9. . Containers Intact: Yes ❑No ❑NIA 10, Filtered volume received for Dissolved tests Oyes ❑No ' IA 11, Sample Labels match COC: -Includes dateltimellblAnal sis Matrix: Yes ❑No ❑Nm 12. All containers'rieeding preservatlori have been checked. All contalners needing preservation are found to be in compilance with EPA recommendation. exceptions: VOA, coliform, TOC, 0&G, WI-DRO (water} fes ❑No EINIA as ❑No ❑N!A yes EJNo 13. Samples checked for dechlorination: vas ❑No ❑N!A 14. Headspace_in VOA Vials ( >6mm): ❑Yes DNo IA 15. Trip Blank Present: Trip Blank Custody Seals Present Pace Trip Blank Lot # if: purchased): ❑Yea LlNo ir.INIA ©Yes ❑ No. AINIA 16. Client Notiflcatiori! Resolutlori: Field Data Repaired? y I N Person Contacted. Date/Time: Comments! Resolution: SCURFISRF Review:: E}ate: Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this .form v0l be nynt to the North Carolina DEHNR Certification Office( i.e out of hold, Incorrect preservative, out of temp,' Incorrect cr-Malnem, uoa: e2zszame IIIIIIf09 Mllllllll llnl A O Page 3 of 3 ac�Analytical www.peadabs.com I Laboratory Report Wilbur Moore Wade Moore Equipment Company PO Box 546 Louisburg, NC 27549 Project: WADE MOORE - SITE 1 & 2 Pace Project No.: 92279728 Pace Analytical Services, Inc. 6701 Conference Drive ` Raleigh, NC 27607 (919)834-4984 Page 1 of t Report Date: 12/24/2015 Date Received: 12/14/2015 Sample: SITE 1 GP Lab ID: 92279728001 Collected: 12/14/15 08:15 Matrix: Water Method Parameters Results Units Report Limit Analyzed Qualifiers SM 2130B Turbidity 19.7 NTU 0.50 12/15/15 12:51 SM 2540F Total Settleable Solids ND mUUhr 0.10 12/15/15 12:40 SM 4500-H+B pH at 25 Degrees C 7.0 Std. Units 1.0 12/22/15 15:03 H6 SM 2540D Total Suspended Solids 25.4 mg/L 5.0 12/16/15 09:26 Sample: SITE 2 RP Lab ID: 92279728002 Collected: 12114/1 5 08:30 Matrix: Water Method Parameters Results Units Report Limit Analyzed Qualifiers SM 2130B Turbidity 5.2 NTU 0.50 12/15/15 12:51 SM 254OF Total Settleable Solids ND mUUhr 0.10 12115/15 12:40 SM 4500-H+B pH at 25 Degrees C 6.2 Std. Units 1.0 12/22/15 15:03 H6 SM 2540D Total Suspended Solids 4.1 mg[L 2.8 12/16/15 09:26 ANALYTE QUALIFIERS H6 Analysis initiated outside of the 15 minute EPA recommended holding time. Reviewed by: Brittany Gibson for Terri Page terri.page@pacelabs.com Raleigh Certification IDs 6701 Conference Drive, Raleigh, NC 27607 North Carolina Wastewater Certification #: 67 Asheville Certification IDs 2225 Riverside Drive, Asheville, NC 28804 Florida/NELAP Certification #: E87648 Massachusetts Certification #: M-NC030 North Carolina Drinking Water Certification #: 37712 Eden Certification IDs 205 East Meadow Road Suite A. Eden, NC 27288 North Carolina Drinking Water Certification #: 37738 North Carolina Bioassay Certification #: 16 North Carolina Drinking Water Certification #: 37731 North Carolina Wastewater Certification #: 40 South Carolina Certification #: 99030001 West Virginia Certification #: 356 VirginiaNELAP Certification #: 460222 North Carolina Wastewater Certification #: 633 Virginia/VELAP Certification #: 460025 Page 1 of 3 aceAnalytical www.pacelabs.com 6701 Conference Drive, Raleigh, NC 27607 ph: (919) 834-4984, fax: (919) 834-6497 NCWW Cert#67, NCDW Cert#37731 Chain of Custody Wn #g,72- -TV Report Result b: p Company: Address: F p I) Box 54-(o Phone: Fax: _., lq_ 4, Sampled by (signature): a Project Reference: Project Number: Purchase Order #: ❑ Standard Report Delivery ❑ Rush Report Delivery (wlsurcharge) "Rush projects are subject to prior approval by the laboratory Requested Due Date: Reli ed by (signatur R ceived { ' na e) Da �� is Time 5 Relinquish (signature) eceived by (signs re) Dat4 Time Relinquished by (signature) Received by (signature) Date Time Receipt Conditions ( U e Only) ❑ 4f2°C ❑ Temp°C Res. Chlorine: ❑ Absent ❑ Present ❑ n!a Acid preserv. <27 ❑ Yes ❑ No ❑ nla Base preserv. >12? ❑ Yes ❑ No ❑ n/a Page 2 of 3 .� Document Name: Sample Condition Upon Document Revised: May 15,-2015 CBAl181yt1Cc71 Recel t SCUR Page 1 of 2* Document No.: Issuing Authorities: F-RAL-CS-001-rev.03 Pace Raleigh Quality Office 'Page 2 of 2 is for Internal Use Only Client Name: Courier (Circle): Fed Ex UPS USPS Client Commercial Pace Other Custody.Seal on Cooler/Box Present: ❑ yes �' no Seals intact: yes no Packing Material: ❑ Bubble Wrap s None Other _ Circle Thermometer Used: IR Gun S :122065387 o of Ice: Wet Blue None Samples on ice, cooling process has begun IR Gun Bac 22065371 Temp Correction Factor:' Add ! btract �. _., C Date and Initials of person examining i r Corrected Cooler Temp.:�� C Biological Tissue Is Frozen: Yes No, IA co t is I Pr .ery on check: Temp should be above freezing to 6°C Comments: Chain of Custody Present: Yes ONO " ❑NIA 1: Chain of Custodj Filled Out: Yes ONO ❑NIA 2: Chain of Custodx Relinquished: Yes ONO ❑NIA 3... Sam ler Name 8 Signature on COC: Yes ONO ❑NIA 4. Samples Arrived within Hold Time: Yes ONO ONIA 5; Short Hold Time Analysis <72hr : Yes ONO ❑N1A 6t - So Rush Turn Around Time Ro4uested: ❑Yes No ❑NrA .7. Sufficient Volume:- Qes ON. ❑NIA S. Correct Containers Used: Yes ONO ❑NIA 9. -Pace Contbinefs Used; Yes . ONO ❑N/A Containers Intact:.' Yes [IN. ❑N!A .10. Filtered volume received for Dissolved tests ' ❑Yes ❑No NIA 17: " Sample Labels;match COC: C�lYes ONO -❑NrA 12, -Includes dateltimellD/Anal sis Matrix: All containers rfeeding preservation have been checked. Yes ONO ❑NIA 13. All containers needing preservation are found to be in Yes ONO ❑NrA compliance with EPA recommendation. exceptions: VOA, ooliform, TOC, O&G, W I-DRO (water) Yes ONO Samples checked for dechlorination: Yes ❑No ❑NIA 14. Headspace in VOA Vials >6mm): ❑Yes ONO NIA 15. Trip Blank Present: ❑Yes ONO NrA 16, Trip Blank Custody Seals Present Oyes ❑No �N/A. Pace Trip Blank Lot #. if purchased): Client Notif aitinnl Resolution: Field Data Required? Y I N Person Contacted: DateMme: Comments/ ResOution: . SCURF lSRF Date: Review:: Note: Whenever there is a discrepancy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina DEHNR Certification Office ( Le out of hold, Incorrect preservative, out of temp, Incorrect containers) Place label here OR WO#:92279728 1111111111111111111111 Page 3 of 3 W-onalyfical www.pacdabs.00m Wilbur Moore Wade Moore Equipment Company PO Box 546 Louisburg, NC 27549 Project: WADE MOORE SAMPLING 09/21/15 Pace Project No.: 92268433 Sample: SITE 01 GP Parameters Turbidity Total Settleable Solids Total Suspended Solids pH at 25 Degrees C hC� aL6 01 q Laboratory Report Lab ID: 9226843300 Results Units 18.9 NTU ND mL/Llhr 18.7 mg/L 8.0 Std. Units Pace Analytical Services, Inc. 6701 Conference Drive Raleigh, NC 27607 (919)834-4984 Page 1 of 1 Report Date: 09/28/2015 Date Received: 09/21 /2015 1 Collected: 09/21/15 09:15 Matrix: Water Report Limit Analyzed Qualifiers 0,50 09122/1516:23 0.10 09/22/1516:01 4.5 09/24/15 09:39 1.0 09122/1514:58 H6 Sample: SITE 02 RP Lab ID: 92268433002 Collected: 09/21/15 09:00 Matrix: Water Parameters Results Units Report Limit Analyzed Qualifiers Turbidity 18.2 NTU 0.50 09/22/1516:23 Total Settleable Solids ND mLJLJhr 0,10 09/22/15 16:01 Total Suspended Solids 12.5 mg/L 6.2 09/24/15 09:39 pH at 25 Degrees C 7.9 Std. Units 1.0 09/22/15 14:58 H6 ANALYTE QUALIFIERS H6 Analysis initiated outside of the 15 minute EPA recommended holding time. Reviewed by: Terri Page terri.page@pacelabs.com Raleigh Certification IDs 6701 Conference Drive, Raleigh, NC 27607 Notch Carolina Wastewater Certification #: 67 Eden Certification IDs 205 East Meadow Road Suite A, Eden, NC 27288 North Carolina Drinking Water Certification #: 37738 North Carolina Bioassay Certification #: 16 North Carolina Drinking Water Certification #: 37731 North Carolina Wastewater Certification #: 633 VirginiaNELAP Certification #: 460025 Page 1 of 3 �ceAnalytical www.pacelabs.com 6701 Conference Drive, Raleigh, NC 27607 ph: (919) 834-4984, fax: (919) 834-6497 NCWW Cert#67, NCDW Cert#37731 Chain of Custody Report Result To: j�j Company: (n] ' '1RA 0 Address: -l�D Attn: Wr bIJLiQV ID01E Phone: Q— `!a- 3771 Fax: 9- 10 - ��� $ --- Sampled by (signature): Bill : Bill `Box 5+�e wo,_ Project Reference: Project Number: Purchase Order #: ❑ Standard Report Delivery ❑ Rush Report Delivery (wlsurcharge) "Rush projects are subject to prior approval by the laboratory Requested Due Date: 'n '�MAS Form wall tti..WF ■ is ���'�1 734 ,yam. Jz ■��■,. Reli uished by (signatur�e Al� ive b i t ) Da e Z� Time 10.. Rellinquiglifa by (signature) Received by (signature) Da a Time Relinquished by (signature) Received by (signature) Date Time Receipt Conditions Le Only) ❑ 4f2°C ❑ Tern °C Res. Chlorine: El Absent ❑ Present L3 n/a Acid preserv. ¢2? ❑ Yes ❑ No ❑ n/a Base preserv. >12? 0 Yes 1771 No ❑ age 2 of 3 Document Name: Sarnple_Cn— dr"tIIon Upgn ;Document Revised May i 9:2015 �' l-ece€ t $QUR1 �` '.;x 4 1 Pa a 1, of .aceAalytical _ ...� �'1Y✓nPa lPbe �,�m .,, , "lssuing`Atlth'6d1ies; f. i3cutOignt F- tAL-CS 001-rev 03 f ` s ` Pace Ralel h.Qual•ty Offire *Page 2 of 2, is for Intemal Use Only Client Name. . .................. Courier (Circle): Fed Ex UPS USPS Client Commercial Pace Other Custody Seal on Cooler/Box Present: ❑ yes . no Seals intact: yes no Packing Material: 0 Bubble Wrap Bags 1 Nane Other Circle Thermometer Used: iR Gun 065387T of Ice Wet Blue None ' Samples on ice, cooling process has bectun IR Gun B O65371 .Temp Correction Factor: Add Corrected Cooler Temp.: •_C p•: Temp should be above freezing to 6°C .,�k-�C" Biological Tissue is Frozen: Yes Na NIA Comments: Date and Initials of perso exa Ining co nt ! r tn�, check:: LL Chain of Custody Present: Yes ONO ❑NIA 1. Chain of Custody Filled Out: es ONO ❑NIA 2. Chain of Custody Relinquished: Yes ONO ❑NIA 3, Sampler Name & Signature on COC: Yes ❑No ❑WA 4. Samples Arrived within Hold Time: Yes ONO ❑NIA 5. Short Hold Time Anal sis(Mhr): Yes ❑too ❑NIA 6� j Rush Turn Around Time Requested: ❑Yes Na ❑NIA T Sufficient Volume: Yes ONO ❑NIA 8. Correct Containers Used: -Pace Containefs Used: es ONO LLL Yes ONO ❑NIA ❑NIA 9. Containers Intact: Yes ONO G]NIA 10. Filtered volume received for Dissolved tests- ❑Yes ONO 7NIA 11. Sample Labels match COC: -Includes datefiime/ID/Anal sis Matrix: 17yes ❑No ❑NIA 12. All containers needing preservation have been checked. All containers needing preservation are found to be in compliance with EPA recommendation. exceptions: VOA, coliform, 70C, 0&G, WI-DRO (water) Yes ❑No r ❑No Yes ❑No ❑NIA ❑NIA 13. Samples checked for dechlorination: es ONO ❑NIA 14. Headspace in VOA Vials (>6mm): el ❑Yes ❑No eTNIA 15. Trip Blank Present: Trip Plank Custody Seals Present Pace Trip Blank Lot # (if purchased): ❑Yes El No' NIA ❑Yes ONO P&A 16. Client Notification/ Resolution: Field Data Required? Y I N Person Contacted: Date/Time: Comments/ Resolution: SCURF lSRF Date: 1r Review:: Note: Whenever there is a discrepa cy affecting North Carolina compliance samples, a copy of this form will be sent to the North Carolina DEHNR Certification Office ( i.a out of hold, incorrect preservative, out of temp, incorrect containers) Place label here OR Handwrite project number (if no label available) Page 3 of 3 North Carolina Beverly Eaves Perdue Governor ffLN 7A NC®ENR Department of Environment and Division of Water Quality Betty Redmond Wade Moore Equipment Company PO Box 546 Louisburg, NC 27549 Dear Permittee: Coleen H. Sullins Director February 11, 2010 Natural Resources Dee Freeman Secretary Subject: NPDES Stormwater Permit Coverage Renewal Wade Moore Equipment Company COC Number NCG020019 Franklin County In response to your renewal application for continued coverage under stormwater General Permit NCG020000 the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater General Permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated October 15, 2007 (or as subsequently amended). The following information is included with your permit package: • A new Certificate of Coverage • A copy of stormwater General Permit NCG020000 • A copy of a Technical Bulletin for the General Permit • Two copies of the Tier 2 / Exceedence Discharge Monitoring Report (DMR) Form for Stormwater • One copy each of the Annual Summary DMR Forms for Stormwater and Wastewater • Two copies of the Limit Violation DMR Form for Wastewater • Two copies of the Qualitative Monitoring Report Form The General Permit authorizes discharges of stormwater and wastewater, and it specifies your obligations with respect to discharge controls, management, monitoring, and record keeping. Please review the new permit to familiarize yourself with all the changes in the reissued permit. If your Certificate of Coverage (COC) restricts authorization to discharge Stormwater only (or other limited terms) based on your original application, or subsequent modifications to your COC, you must continue to meet these requirements or contact the Stormwater Permitting Unit to request a modification of this renewal COC. The more significant changes in the General Permit since your last Certificate of Coverage include the following: Part Il: • Section B — Language referencing PAMS has been changed. Flocculants may now be used if evaluated by the Division and administered in accordance with maximum application doses and other requirements. Part III: • Section A — The permit now requires a Stormwater Pollution and Prevention Plan (SPPP) tailored to the mining industry, in lieu of a Stormwater BMP Plan. • Section A - Inactive mines may be inspected on a reduced schedule: at least once per month and after 0.5" (or more) of rain. To qualify, inactive mines must possess an "Inactive Renewal" from DLR or certify to DWQ the site has been stabilized. The permittee must notify the DWQ Regional Office of inactive status. Discharges from inactive mines must still be monitored on the same schedule as active mines. Wetlands and Stormwater Branch 1617 Mail Service Center, Raleigh, North Carofma 27699-1617 One Location: 512 N, Salisbury 5t Raleigh, North Carolina 27604 NorthCaroiina Phone919-807-6300SFAX: 919-807-64941Customer Service:1-877- 23-6748 Internet: www.mcwaterquality.org Avapally An Equal Opportunity 4 Affirmative Action Employer A Permit Reissuance -- Permit Number NCGO20019 February 11, 2010 Page 2 • Section B — Revised provisions require that stormwater discharges be sampled twice per year (instead of annually), and that the sampling results be compared to new benchmark values. (The previous cut-off concentrations have been removed.) • Section B — Revised provisions require the permittee to execute Tier One, Tier Two & Tier Three response actions, based on the first benchmark exceedence (Tier One) and the second consecutive benchmark exceedence (Tier Two). Tier Two requires that the permittee institute monthly monitoring (reported to the appropriate Regional Offices) instead of twice -per -year monitoring. Monthly monitoring shall be done until three consecutive monitoring events show no benchmark exceedences. • Section B —This part contains a new provision that four exceedences of any benchmark will trigger increased DWO involvement in the permittee's stormwater management and control actions. DWO may direct the permittee to apply for an individual permit, institute specific monitoring, or may direct the implementation or installation of specific stormwater control measures. • Section B — The definition of "Representative Storm Event" (RSE) now allows 48 hours (instead of 72 hours) of little or no precipitation to precede an RSE. • Section B — Stormwater discharges from a basin designed to contain the 10-year storm must now be monitored. • Sections B & C — Failure to monitor according to permit terms triggers monthly monitoring for the remainder of the permit. • Section C — Analytical monitoring for Total Petroleum Hydrocarbons (TPH) has replaced the Oil & Grease parameter in the previous permit. • Section D — Qualitative monitoring must now be conducted during the same representative storm event as the analytical monitoring. • Section D — The permittee is required to keep a written record of his response to problems identified by his qualitative monitoring observations. • Section D — If the permittee fails to respond effectively to problems identified by qualitative monitoring, the permittee may be required by DWO to perform corrective action. • Section D — Qualitative ROS: Representative Outfall Status may be granted for qualitative monitoring for some Stormwater Discharge Outfalls (SDOs). • Section D — If mines do not respond to problems seen in visual monitoring, DWQ may now require that mines change the monitoring frequency, apply for an individual permit, implement in -stream monitoring, install or modify structural stormwater controls, or implement other controls. • Sections B, C, & D — Inability to sample due to adverse weather must be reported in the SPPP and recorded in the Annual Summary DMR. • Section E — A lower TSS Wastewater limit for PNA waters is included in the permit. • Section E — All mining operations are now required to monitor TSS in wastewater effluent discharges (not only industrial sand mines). However, TSS limits only apply to industrial sand mining operations. • Section E — Turbidity limits on effluent discharges have been removed; however, turbidity standards still apply in the receiving waters. • Section E — Approval of a Pumping O&M Plan may be required prior to coverage (for sites with dewatering activities that have the potential to drain wetlands or other surface waters). • Section E — ATC Requirements have been changed for clarity. These requirements are now outlined for Mine Dewatering Wastewater, Process Wastewater, Overflow From Non -Closed -Loop Process Recycle Wastewater Systems, and Overflow From A Closed -Loop Process Recycle (CLPR). • Section E -- Monitoring for Fecal coliforms in discharges to SA waters has been clarified. Fecal coliform monitoring is now required for all process and mine dewatering wastewater discharges to SA waters. Part IV: • Section E — Items 1. and 2. require submittal of a new reporting form: the Annual Summary DMR. This annual summary of the analytical monitoring results should be submitted to the DWO Central Office by March 1 of each year. • Section E — Exceedences and violations must be sent to the appropriate DWO Regional Office within 30 days of receipt from the lab. • Section E — Results of "No Flow" or "No Discharge" must be recorded within 30 days from the sampling period in the SPPP. "No flow" or "No Discharge" must also be reported on the Annual Summary DMR form. 'AW Permit Reissuance — Permit Number NCG020019 February 11, 2010 Page 3 Your coverage under the General Permit is transferable only through the specific action of DWO. This permit does not affect the legal requirements to obtain other permits which may be required by DENR, nor does it relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package please contact these members of the Stormwater Permitting Unit: Jennifer Jones at (919) 807-6379 or Bethany Georgoulias at (919) 807-6372. cc: DWQ Central Files Stormwater Permitting Unit Files Raleigh Regional Office Sincerely, _Iar- Coleen H. Sullins r., STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCG020019 STORMWATER, MINE DEWATERING WATER AND/OR PROCESS WASTEWATER NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Wade Moore Equipment Company is hereby authorized to operate approved wastewater treatment system(s) and discharge stormwater and/or wastewater, as approved in the original permit/application or subsequent permit modification, from a facility located at: Wade Moore Equipment Company Fleming Pit Louisburg Franklin County to receiving waters designated as TAR RIVER, a class WS-IV;NSW waterbody in the Tar -Pamlico River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, II, III, IV, V, and VI of General Permit No. NCG020000 as attached. This certificate of coverage shall become effective February 11, 2010. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this 11`h day of February, 2010. for Coleen H. Sullins, Director Division of Water Quality By Authority of the Environmental Management Commission e WADE MOORE EQUIPMENT COMPANY, INC. P.O. Box 546 Louisburg, North Carolina 27549 (919) 496.3794 November 23, 2009 Dave Parnell Environmental Specialist N.C. Division of Water Quality Surface Water Protection 1628 Mail Service Center Raleigh, North Carolina 27699-1628 Ref: NPDIS Stormwater General Pcrmit NCG020019 Dear Mr. Parnell: NOV Attached are lab reports for the two outfalls in the Fleming Sand Pit as done by Tritest Laboratory, Raleigh, North Carolina. Sincerely, �� ". Betty Jo R c�mond Secretary-Treasurcr Attachments: 2 QUALITY SAND, AT A QUALITY PRICE! o Page 1 of 1 7ROOTEST Laboratory Report Lob Locafron 'R' Lab Location 'C' Lab Location 'W' NCWW Cert.#: 067 NCIDW Cert.#: 37731 NC/WW Cert.#: 103 NCIDW Cert.#: 37733 NCNUW Cert.#: 075 NC1DW Cert.#: 37721 6701 Conference Dr, Raleigh, NC 27607 6300 Ramada Dr, Suite C2, Clemmons, NC 27012 6624 Gordon Rd, Unit G, Wilmington, NC 28411 Ph: (919) 834-4984 Fax: (919) 834-6497 Ph: (336) 766-7846 Fax: (336) 766-2514 Ph: (910) 763-9793 Fax: (910) 343-9688 Project No.: Project ID: STORMWATER --- Prepared for --- WILBUR MOORE WADE MOORE EQUIPMENT COMPANY P. O. BOX 546 SHIP:934 EAST RIVER ROAD LOUISBURG, NC 27549 Report Date: 1012712009 Date Received: 10/1312009 Work Order #: 0910-00936 Cust. Code: WA3794 Cust. P.O.* No. Sample ID y� Date Sampled Time Sampled Matrix Sample Type Condition 001 STORMWATER ` of%A 1 10113/2009 8:00 SW Grab 4 +/- 2 deg C - - - - - - I zed -------- Test Performed Method Results Lab Loc a� Time Qualifier Settleable Solids EPA 160.5 <0.1 mUL R 10/13/09 13:15 Total Suspended Solids SM 2540D 3.7 mg/L R 10/13109 14:00 pH EPA 150.1 7.02 S.U. R 10126/09 15:00 pH disclaimer Exceeds holding time. R 10/26/09 14:19 Turbidity EPA 180.1 6.0 NTU R 10/14/09 16:00 Reviewed by: zh� W� for Tritest, Inc. 1 0 o Page 1 of 1 V nTEST Laboratory Report Lab Location 'K' Lab Location 'C' Lab Location 'W' NCIWW Cert.#: 067 NCIDW Cert.#: 37731 NCMMI Cert.#: 103 NCIDW Cert.#: 37733 NGNMCert.#: 075 NCIDW Cert.#: 37721 6701 Conference Dr, Raleigh, NC 27607 6300 Ramada Dr, Suite C2, Clemmons, NC 27012 6624 Gordon Rd, Unit G, Wilmington, NC 28411 Ph', (919) 834-4964 Fax: (919) 834-6497 Ph: (336) 766-7846 Fax: (336) 766-2514 Ph: (910) 763-9793 Fax: (910) 343-9688 Project No.: Project ID: STORM WATER -- Prepared for --- WILBUR MOORE WADE MOORE EQUIPMENT COMPANY P. O. BOX 546 SNIP.934 EAST RIVER ROAD LOUISBURG, NC 27549 Report Date: 11/10/2009 Date Received: 11/2/2009 Work Order # Cust. Cade: Cust. P.O.#: 0911-00088 WA3794 No. Sample ID `� Date Sampled Time Sampled Matrix Sample Type Condition 001 STORM WATER 1 oy-A C� 111212009 10:15 SW Grab 4 +1- 2 deg C Test Performed Method Results Lab Loc Da�Zed Time Qualifier Settleable Solids EPA 160.5 <0.1 mL1L R 11/3109 15:40 Total Suspended Solids SM 2540D 4.9 mg1L H 1113/09 10:05 PH EPA 150.1 6.90 S.U. H 1119/09 15:45 PH disclaimer Exceeds holding time. H 1119109 14:56 Turbidity EPA 180.1 5.7 NTU 12 1113109 15:45 Reviewed by: for Tritest, Inc. .q NC®ENR North Carolina Department of Environment and Natural Resources Division of Water Quality Beverly Eaves Perdue Coleen H. Sullins Dee Freeman Governor Director Secretary June 2, 2009 Mr. Wilbur W. Moore, President Wade Moore Equipment Company, Inc. P. O. Box 546 Louisburg, NC 27549 Subject: Compliance Evaluation Inspection NPDES Stormwater General Permit NCG020019 Wade Moore Equipment Company — Sand Mine Franklin County Dear Mr. Moore: On May 29, 2009, I, Dave Parnell of the Raleigh Regional Office of the Division of Water Quality, performed a compliance evaluation inspection (CEI) at your sand mining facility. Your assistance was helpful and appreciated. This inspection was conducted to determine your compliance with NPDES stormwater general permit referenced above. The following observations were noted during the Division of Water Quality inspection: SITE DESCRIPTION Sand products are currently being mined at this facility. There are two stormwater discharge outfalls (SDO) at the facility, one active (SDO 002), and one that discharges only in extreme rainfall events (SDO 001). The flow at SDO 002 was continual at the time of the inspection and requires both qualitative and analytical monitoring. The process wastewater and stormwater are commingled in both SDO drainage areas. The process wastewater produced from the sand washing operation flows through Four ponds and is then re -circulated back to the sand washing operation. During the CEI, you indicated that this type of wastewater treatment is known as a closed loop recycle system with designed 2-foot freeboard. The wastewater does not discharge at SDO 001, except during a heavy rainfall event. The last time you recorded a discharge was during Tropical Storm Hanna in September, 2008. Vehicle maintenance is conducted at this facility, but less than 55 gallons of used oil is produced per month and therefore no analytical monitoring is required. oNtmi-ally ehCarolina North Carolina Division of Water Quality Raleigh Regional Office Surface Water Prctection Phone (919) 791-4200 Customer Service Internet: www.ncwaterquality.org 1628 Mail Service Center Raleigh, NC 27699-1628 FAX (919) 788-7159 877-623.6748 An Equal Opportunity/Affirmative Action Employer — 50% Recycled/10% Post Consumer Paper Wade Moore Equipment Company Inc. + Compliance Evaluation Inspection INSPECTION SUMMARY The Stormwater General Permit was available during the inspection. The permit expires on December 31, 2009. Please note that an application for renewal is required 6 months prior to expiration of the permit. 2. The Best Management Practices (BMP) plan was available during the CEI. I reviewed the documented records of BMP inspections and they were in good order. 3. Both SDO were visited during the inspection. As noted above, SDO 001 has infrequent flow, but qualitative and analytical monitoring is required when a flow is present. A record of the monitoring for SDO 001 is required. When the flow is absent, the comment "no flow" should be entered on the monitoring report. Qualitative monitoring is currently being conducted at SDO 002. I discussed with you suggestions for improving your record keeping, as well as the required frequency of the monitoring. Analytical monitoring is not being conducted as required for SDO 002. Please conduct qualitative and analytical monitoring as required by your permit. The possibility that permit requirements could change in the next permit cycle was pointed out to you during the site visit. Please address and respond in writing to the above item, shown in bold. to this office, by July 2, 2009. If you have any questions regarding the attached report or any of the findings, please contact me at: (9I9) 791-4200 or email: david.parnellnRncdennizov. Sincerely, 0.,4 Dave Parnell Environmental Specialist Surface Water Protection Section Enclosure: May 29, 2009, Compliance Evaluation Inspection Cc rRRO/SWP files I DWQ Stormwater Permitting Unit f Permit: NCG020019 SOC: County: Franklin Region: Raleigh Compliance Inspection Report Effective: 01/19/05 Expiration: 12/31/09 Owner: Wade Moore Equipment Company Effective: Expiration: Facility: Wade Moore Equipment Company Fleming Pit Contact Person: Wilbur W Moore Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Louisburg NC 27549 Title: Phone: 919-496-3794 Certification: Phone: Inspection Date: 06/2912009 Entry Time: 10:00 AM �/�jfJ Exit Time: 12:20 PM Primary Inspector: David R Parnell /`'QJ /Lr?r[�� Phone: 919-791-4260 Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Mining Activities Stormwater Discharge COC Facility Status: ❑ Compliant D Not Compliant Question Areas: Storm Water (See attachment summary) Page: 1 f Permit. NCGO20019 Owner - Facility: Wade Moore Equipment Company Inspection Date: 05/29/2009 Inspection Type: Compliance Evaluation Reason for Visit: Routine Inspection Summary: Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? ■ ❑ ❑ ❑ Comment. Qualitative monitoring has been done on SDO 002, but more frequently _... ,. and not as thorough as required. Discussed with Mr. Moore what parameters are needed to be included in the Qualitative Monitoring forms. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ ■ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ■ ❑ Comment: Analytical monitoring is required for both SDO 001 and 002. SDO 001 has infrequent flow and discharges only during extreme rainfall events. Report "no flow" when recording non discharge analytical monitoring results. Permit and Outfalls Yes No NA NE # is a copy of the Permit and the Certificate of Coverage available at the site? ■ ❑ ❑ ❑ # Were all outfalls observed during the inspection? ■ ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ ■ ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ■ ❑ ❑ ❑ Comment: Page: 2 S&ME l August 16, 2006 North Carolina Division of Environment and Natural Resources Division of Water Quality Raleigh Regional Office 3800 Barrett Drive Raleigh, North Carolina 27699-1628 Attention: Mr. Charles Wakild, P.E. Surface Water Quality Supervisor Reference: Notice of Violation NOV-2006-PC-0298 AUG t � 2�,On NPDES General Permit NCG020000; Certificate of Coverage NCG020019 Wade Moore Equipment Company Inc. Louisburg, North Carolina S&ME Project No. 1054-06-354 Dear Mr. Wakil& On behalf of Wade Moore Equipment Company, Inc,, S&ME, Inc. (S&ME) is issuing this letter to address item #s 3, 5, and 6 in the July 17, 2006 Notice of Violation (NOV) to Wade Moore Equipment Company's NPDES General Stormwater Permit NCG020000/Certificate of Coverage NCG020019. A response to iterns #3, #5 and #6 is presented below. Several Best Management Practices (BMPs) on the site have been developed wid implemented including: vegetative swales and berzxis on reclaimed mute areas. a series of settling ponds for stormwater and process wastewater, rip rap diversions, and a perforated aluminum riser pipe to filter effluent from the Final settling; ponds before release into the Tar River. However, a written BMP .Plan has not been developed in accordance, with the requirements of Section A (1) of the permit. According to Mr. Moore, all stormwater BMP's are inspected daily and within 24 hours of any storm event, but no written recorded log of the inspections is kept. S&ME has been retained to evaluate existing BMPs and to develop a BMP Plan to comply with Section A (1) of the permit. Before an effective BMP Plan can be developed, an updated topographic survey of Wade Moore Equipment Company's site is needed to evaluate existing BMPs and, if necessary, to assist in the design of new BMi's. GeoData Corporation, a North S&ME, INC. 13201 Spring Forest Road 1 Ra4eigh, NC 27616 1 p 919.872.2660 f 919.876.39581 www.smeinc.com Response to NOV-2006-PC-0298 S&ME Project No. 1054-06-354 Wade Moore Equipment Company Inc., Louisburg, NC_ August 16, 2006 Carolina Licensed Land Surveyor, has been retained to survey the site using aerial photography with ground control to develop a topographic survey with 2-foot contour intervals. The survey will also provide the locations of existing operational areas, settling ponds, and other BMP structures on the site. The survey is expected to be completed by mid September. Once the survey is in hand, S&ME will complete the BMP Plan within two to three weeks. 5. Part II, Section B (7) of the permit states that no chemical flocculants shall be used in the treatment facility without written autbozization from the Division of Water Quality. Mr. Moore indicated that lie uses Floe ,Log distributed by Applied Polymer Systems, Tic. in Atlanta, Georgia. There is no record of written authorization for the use of the Floc. Log in the file. Ms. Betty .1. Redmond of Wade Moore E,quipment Company, Inc., submitted a request to use Floc Log to Mr. Alan W, Klimek, P.E., Director of DWQ, on July 18, 2006. Mr. Klimek approved the use of the product, Floc Log (APS #703D) manufactured by Applied Polymer Systems, Inc., which is documented in a letter dated July 26, 2006 (see attached). The attached letter is provided to comply with fart Il Section B (7) of the permit as written authorization to use a chemical flocculent. 6. No analytical monitoring has beeu, conducted at the site. The permit requires analytical monitoring for Mine Dewatering Wastewater, and Water Associated With Saud Mining. Part III, Section C, Tables 6 & 7 of the permit should be used for guidance for the monitoring. Wade Moore Equipment Company, Inc., currently has two stormwater discharge outfalls (SDOs). SDO-1 receives discharge of a mixture of stormwater runoff and wastewater from sand mining. SDO-2 receives mine de -watering discharge from the active sand pit. While the BMP Plan is being developed, S&ME will implement a monitoring schedule for the quantitative monitoring requirements for stormwater, wastewater from sand mining, and mine dewatering wastewater. This monitoring schedule will begin in September 2006 and continue quarterly thereafter. Qualitative (visual) monitoring will also commence in September 2006. Qualitative monitoring; for each outfall will be conducted twice a year thereafter, once in the spring and once in the fall, following the schedule outlined in the permit. Documentation of monitoring events will be kept on -site as required by the permit. 2 Response to NOV-2006-PC-0298 S&ME Project No. 1054-06-354 Wade Moore Equipment Company, Inc., Louisburg, NC _ _ August 16, 2006 It is Wavle Moore Equipment Company's intent to comply with NPDES General Permit NCG020000/Certificate of Coverage NCG020019 with the assistance of S&ME. Please contact Mr. Edmund Woloszyn, Jr. or Mr. Ken Daly, both with S&ME, at (919) 872-2660 if you have any questions or if we may be of any further assistance to you. Sincerely, S&ME, Inc. Ken Daly, P.E. Senior Project Engineer Abnegs, Jr., 11.1-. b Senior Reviewer Edmund Woloszyn; Jr., REM Senior Project Manager Attachment: Letter dated July 26, 2006 from Mr. A.W. Klemik, DWQ Re: Floc Los SAPROJECTS12006106-354 Wade Moore BMP PlanlCorresporndence\Rcsponse to NOV.doc 3 ry . p�oF wAr,�RQ� Y J1 J`+JV/u- July 26, 2006 Ms. Betty Jo Redmond Secretary -Treasurer Wade Moore Equipment Company, Inc. P.O. Box 546 Louisburg, NC 27549 Subject: Use of Floc Log NPDES Permit No- NCGO20019 Franklin County Dear Ms- Redford: Michael F. Easloy, Govemor William G Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division of Water Quality In response to your letter of July 18, 2006, regarding approval for the use of Floc Log (APS #703D), the Division authorizes you to utilize this product in accordance with the conditions of your permit and the conditions outlined herein. Applied Polymer Systems has performed toxicity tests on several of their products and has received blanket approval to use them as a treatment method to reduce turbidity. Attached is a list of all of the products that have received approval from the Division. The first four products were approved if used at or below the Maximum Application Concentration listed and the "block" or "log" products were approved if used according to the manufacturer's specifications. We appreciate you asking for this information. If you have any specific questions, feel free to contact Mr. Boyd DeVane of the DWQ staff. He can be reached at 919.733.5083 ext 559 or at boyd,devaner@ncmail.net . Sincerely, _�U4 &V� ..• Alan W. Klimek, P.E. Cc: Raleigh Regional Office Central Files Stormwater Unit Files Wetlands and Stormwater Branch 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-5083 tntemet: h2o.ennstatonc.us 512 N. Salisbury St. Raleigh, NC 27604 FAX (919) 733-9612 An Equal OpportunitylAhlrmative Action Employer — 50% Recyded110% Post Consumer Paper AUG I Z V Iff No'" Carolinn 'atura!!� • YJ Z7/rJb/LYS CIO Cld: �! 717470 la70 wr-7t�G i`tuur�l:: ��xt+li i•�uv� �•+�+� �+-+ Poly acrylavoide (PAM) Products Approved Applicatic.)i7 Concentrations Company Product Maximum Application Concentration ( rn) Applied Pol mer Systems .APS 705 27.7 Applied Polymer Systems APS 712 59.3 Applied P2 mer Systems APS 730 5.6 Applied Polymer Systems I ,APS 740 5.2 Appxoved PolyacTylamide (PAM) "Block" or "Log" Products* Cora alb. Product App Iied Pol ymer S ystems APS 703d Applied Polymer Systems APS 703d#3 Applied Polymer Systems APS 706b * The supplier has providcd documentation of aquatic toxicity as well as docum oration of maximum dosage rates for each product_ All products have a maximum dosage rate less than their chronically toxic concentration. A ChemTr�eatjnc. MATERIAL, SAFETY DATA SHEET Section 1. Chemical Product and Company Identification Product Name: P-8282L Manufacturer's Name: ChemTreat, Inc. Emergency Telephone Number: (800) 424-9300 Address (Corporate Headquarters) 4461 Cox Road, Glen Allen, VA 23060 Telephone Number for Information: (800) 648-4579 Date of MSDS: March 6, 2006 Section 2. Composition/Hazardous .ingredients Component CAS Registry # wt. % Aluminum chlorhydrate 12042-91-0 45 - 50 Ferric chloride 7705-08-0 0 -10 Section 3. Hazards Identification Emergency Overview: Dark brown opaque liquid; mild odor; not flammable. Potential Health Effects: Eyes: Overexposure may cause discoloration of eye tissue, irritation and discomfort, tearing and blurring of vision, or eye corrosion with corneal or conjunctival ulceration. Skin: May cause irritation with discomfort or rash, burns, or ulceration. Inhalation: May cause irritation of upper respiratory tract, with coughing. Ingestion: May cause corrosive damage to the GI tract. Repeated ingestion of sub -lethal doses may Iead to excessive deposition in the tissues accompanied by pancreatic and liver damage. Chronic Effects/Carcinogenicity: None of the components of this material are listed as a carcinogen by IARC, NTP, OSHA, or ACGIH. Section 4. First Aid Measures Inhalation: Remove victim to fresh air. If not breathing, give artificial respiration, preferably mouth- to-mouth. If breathing is difficult, give oxygen. Get immediate medical attention. Eyes: Hold eyes open and rinse slowly and gently with water for 15 - 20 minutes. Remove contact lenses, if present, after the first 5 minutes, then continue rinsing eye. Get immediate medical attention. Skin: Take off contaminated clothing. Rinse skin immediately with plenty of soap and water for 15 - 20 minutes. Get immediate medical attention. Ingestion: Do not induce vomiting. Give large quantities of water, then an antacid. Never give anything by mouth to an unconscious person. Call a physician. ChemTreat, Inc. P-8282L Page ] Section 5. Fire Fighting Measures Flammable Properties: Not flammable. Suitable Extinguishing Media: Use extinguishing media appropriate for surrounding fires. Fire & Explosion Hazards: Possible formation of hazardous chlorine compounds. Protective Equipment: Wear full protective clothing including a positive -pressure, NIOSH-approved, self-contained breathing apparatus. Section d. Accidental Release Measures Small Spill: Construct temporary dikes of dirt, sand, or any readily available inert material to prevent spreading of the material. Wearing appropriate personal protective equipment, move the leaking container to a containment area, or plug the leak. Neutralize the Iime or other base, then absorb on inert material. Shovel up and dispose of according to local, state and federal regulations. Large Spill: Construct temporary dikes of dirt, sand, or any readily available inert material to prevent spreading of the product. Wearing appropriate personal protective equipment, close or cap valves and/or block or plug hole in leaking container and transfer to another container for proper disposal. Section 7. Handling and Storage Store in closed or covered containers when not in use, in cool, dry areas with adequate ventilation. Do not store near heat or open flames. Exercise caution when handling product. Wash with soap and water before eating, drinking, smoking, or using toilet facilities. Section S. Exposure Controls/Personal Protection Use protective equipment in accordance with 29 CFR 1910, Subpart 1. Good general ventilation should be sufficient to control airborne levels. Wear chemical splash goggles or safety glasses with full -face shield. Wear rubber gloves. Wash them after each use and replace as necessary. If conditions warrant, wear impervious protective clothing such as boots, aprons, and coveralls to prevent skin contact. Maintain eyev,,ash fountain and quick -drench facilities in work area. Section 9. Physical and Chemical Properties Appearance: Dark brown opaque Physical state: Liquid Boiling Point: >230°F Solubility in Water: Complete Evaporation Rate: N/D Specific Gravity: —1.357 Freezing Point: N/D Vapor Density: N/D Melting Point: N/ A Vapor Pressure: N/D Molecular Weight: N/D Viscosity: N/D Odor: Mild % VOCs: N/D pH: —2.9 Flash Point: Not flammable Section 10. Stability and Reactivity Chemical Stability: Stable at normal temperatures and conditions. ChemTreat, ]nc. P-8282L Page 2 Incompatibility: Rapidly corrodes most metals (titanium is one exception); may generate flammable, potentially explosive hydrogen gas. Avoid contact with nylon, aluminum/aluminum alloys, carbon steel, stainless steel, and copper or copper alloys. Hazardous Decomposition Products: None known. Hazardous Polymerization: Will not occur. Section 11. Toxicological Information No information furnished Section 12. Ecological Information Fathead minnow: 574 mg/L Ceriodaphnia dubia: 1464 mg/L Section 13. Disposal Considerations Dispose of in accordance with applicable federal, state and local laws. Section 14. Transport Information (not meant to be all inclusive) D.O.T. Shipping Name: Corrosive liquid, acidic, inorganic, n.o.s. (Ferric Cl-loride) Hazard Class: 8 (corrosive),- UN3264; PG III Section 15. Regulatory Information (Not ineant to be all irsclusi le - selected regulation represented) TSCA Status: All ingredients listed CERCLA Reportable Quantity: Ferric chloride (7705-08-0)1000 lbs. SARA Title III: Section 302 Extremely Hazardous Substances: None Section 313 Toxic Chemicals: None CALIFORNIA PROPOSITION 65: None known Section 16. Other Information HMIS Hazard Rating: Health: 2 Flammability: 0 Physical Hazard: 0 PPE: X (see note) Note: PPE rating depends on circumstances of use. See Section 8 for recommended PPE. SARA Hazard Categories - Section 311/312 Acute - Y Chronic - Y Fire - No Reactive - No Sudden Release - No Prepared by: ChemTreat Regulator)' Affairs Aithangh the illfarnlafion and recommendations se'I forth herein (ilele'iNaller "hrformnlioll ") are Prewnled in goad failh m!d briiewd In be correcl as of the date hereof, ChrlaTreal, Inc waArS no rCl»PSrnfnlinrt5 a5 10 the roaq)lelrness or arrnrary (hereof. hrformaliem is smpphed ulna+ the eondilimr lhal the frrsons receiving same will maAr their own delernuuafion (IS to its suilabihty for their Purposes prior to um. In no rvew will ChemTreat, her. be responsible far daurages of any nalrnr whalsona rrsnlling from the nse or reliance upon+ infmnatimr. No REPRESENTATION OR WARRANTIES, EITHER EXPRESS OR )A1PL1ED, OF AIF.RCHANTABILM, FITNESS FOR A PARTICULAR PURPOSE, OR OF ANT' OTHER NATURE ARE MADE HERELIN'DER IVITH RESP£CT'10;NFORAIATIOA' OR THE. PR00LICT To IVkICLI INFORMATION REFERS. ChemTreat, Inc. P-8282L Page 3 ® ® Michael F. Easley, Governor O of w A TER �pG July 26, 2006 Ms. Betty Jo Redmond Secretary -Treasurer Wade Moore Equipment Company, Inc. P.O. Box 546 Louisburg, NC 27549 Subject: Use of Floc Log NODES Permit No. NCG020019 Franklin County Dear Ms. Redford: William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, P.E. Director Division or Water Quality In response to your letter of July 18, 2006, regarding approval for the use of Floc Log (APS #703D), the Division authorizes you to utilize this product in accordance with the conditions of your permit and the conditions outlined herein. Applied Polymer Systems has performed toxicity tests on several of their products and has received blanket approval to use them as a treatment method to reduce turbidity. Attached is a list of all of the products.that have received approval from the Division. The first four products were approved if used at or below the Maximum Application Concentration listed and the "block" or "log" products were approved if used according to the manufacturer's specifications. We appreciate you asking for this information. If you have any specific questions, feel free to contact Mr. Boyd DeVane of the DWQ staff. He can be reached at 919.733.5083 ext 559 or at boyd,devane@ncmail.net . Sincerely, Alan W. Klimek, P.E. Cc: Raleigh Regional Office Central Files Stormwater Unit Files None hCarolma Natrtra!!y Wetlands and Stormwater Branch 1617 Mail Service Center Raleigh, NC 27699-1617 Phone (919) 733-5083 Internet: h2o.enr.statemc.us 512 N. Salisbury St. Raleigh, NC 27604 FAX (919) 733-9612 An Equal OpportunitylAf6rmative Action Employer — 50% Recycled110% Post Consumer Paper Polyacrylamide (PAM) Products Approved Application Concentrations Collivally Product Maximum Application Concentration (pm) Applied -Polymer S stems -APS-705- -27:7 — A plied Polymer Systems APS 712 59.3 Applied Polymer Systems APS 730 1 5.6 Applied Polymer Systems APS 740 1 5.2 Approved Polyacrylamide (PAM) `Block" or "Log" Products* Coinpany Product Apphed Polymer Systems APS 703d Applied Polymer Systems APS 703d#3 Applied Polymer Systems APS 706b I The supplier has provided documentation of aquatic toxicity as well as documentation of maximum dosage rates for each product. All products have a maximum dosage rate less than their chronically toxic concentration. O�pF W A 1'FgQG Michael F. Easley, Govemor William G. Ross, Jr., Secretary 7 i `a North Carolina Department of Environment and Natural Resources Q Alan W. Klimek, P.E., Director Division of Water Quality July 17, 2006 Betty J Redmond Wade Moore Equipment Company PO Box 546 Louisburg NC 27549 Notice of Violation: NOV-2006-PC-0298 Stormwater Compliance Evaluation Inspection NPDES Permit No. NCG020019 Franklin County Dear Ms. Redmond: Mr. Chad Coburn and Mr. Harry Messenger of the Division of Water Quality, Raleigh Regional Office, conducted an compliance evaluation inspection of the Fleming Pit for coverage under the NPDES permit NCG020019 on July 12, 2006. Wilbur Moore's assistance during the inspection was greatly appreciated. Findings during the inspection are as follows: The following observations were made: The current permit was issued effective February 7, 2005 and expires on December 31, 2009. 2. Stormwater and discharges associated with mine dewatering wastewater, sand mining wastewater, and process wastewater from the site, discharges to receiving waters designated as the Tar River, a class IV Water Supply, nutrient sensitive water (NSW), in the Tar -Pamlico River Basin. 3. Several Best Management Practices (BMP's) on the site have been developed and implemented including: vegetative swales and berms on reclaimed mine areas, a series of settling ponds for stormwater and process wastewater, rip rap diversions, and a perforated aluminum riser pipe to filter effluent from the final settling ponds before release into the Tar River. However, a written BMP Plan has not been developed in accordance with the requirements of Section A (1) of the permit. According to Mr. Moore, all stormwater BMP's are inspected daily and within 24 hours of any storm event, but no written recorded log of the inspections is kept. 4. Since stormwater and process wastewater mix into the settling basins together, any water discharged at either of the two stormwater' discharge outfalls (SDO's) is considered process wastewater. One No hCarolina �l�aturally North Carolina Division of Water Quality Raleigh Regional Office Surface Water Protection Intemet: h2o.enr.state.nc.us 3800 Barrett Drive Raleigh, NC 27699-1628 An Equal CpportunilylAffirmative Action Employer— 50%a Recycled110%a Post Consumer Paper Phone (919) 791-4200 Customer Service FAX (919) 571-4718 1-877.623-6748 Wade Moore Equipment Company NOV-2006-PC-0298 4 2 wti; Part II, Section B (7) of the permit states4that no -chemical flocculants shall be used in the treatment facility without written authorization from the Division of Water Quality. Mr. Moore indicated that he uses Floc Log distributed by Applied Polymer Systems, Inc. in Atlanta, Georgia. There is no record of written authorization for the use of the Floe Log in the file. 6. No analytical monitoring has been conducted at the site. The permit requires analytical monitoring for Mine Dewatering Wastewater, and Water Associated With Sand Mining. Part III, Section C, Tables 6 & 7 of the permit should be used for guidance for the monitoring. 7. Mr. Moore indicated on July 13, 2006 that S & ME, an engineering and environmental services firm, has been hired to implement the monitoring requirements of the permit. Please respond in writing to #'s 3, 5, and 6 by August 18, 2006, with a progress report, noting the specific changes 1 upgrades that you expect to make. If you have any questions regarding the attached report or any of our findings, please contact Mr. Chad Coburn (or email: chad.cobum@ncmail.n_et) or Mr. Harry Messenger (harold.messengerOwncmail.net), at (919) 791-4200. Sincerely, Charles Wakild, P.E. Surface Water Quality Supervisor Raleigh Regional Office Cc: Wilbur Moore, Wade Moore Equipment Company, PO Box 546 Louisburg NC 27549 RRO files Central Files rJ; United Slates Environmental Protection Agency Form Approved. EPA Washington, D.C. 20460 OMB Na. 2040-0057 Water Compliance Inspection Report Approval expires 8-31-98 Section A: National Data System Coding (i.e., PCS) Transaction Code NPDES yrlmolday Inspection Type Inspector Fac Type 1 I NI 2 15I 31 NCG020019 Ill 121 a5/07/12 117 181 WI 191 GI 20I� l J Remarks 211 11 1 I 1 I 1 1 I 1[ I I I I I _I I I I I I I III I 11__1.1 I I I I .I. I I I_ -i_I I I 11-_I6 Inspection Work Days Facility Self -Monitoring Evaluation Rating 131 QA -------------- —------- --- Reserved ----- —--- —------- -- 671 169 701 I 711 I 72I 141 73I I 174 751 I I I I I LJ 80 LJ�J Section B: Facility Data Name and Location of Facility Inspected (For Industrial Users discharging to POTW, also include Entry Time/Date Permit Effective Date POTW name and NPDES permit Number) 11:oo AM 06/07/12 05/01/19 Wade Moore Equipment Company Exit Time/Date Permit Expiration Date Fleming pit Louisburg NC 27549 ol:0o PM 06/07/12 09/12/31 Name(s) of Onsite Representative(s)1Titles(s)/Phone and Fax Number(s) Other Facility Data Name, Address of Responsible OfficiallTitte/Phone and Fax Number Contacted Betty .7 Redmond,PO Box 546 Louisburg NC 27549//919-496-3794/9194967894 0 Section C: Areas Evaluated During Inspection (Check only those areas evaluated) Storm Water Section D: Summary of Finding/Comments Attach additional sheets of narrative and checklists as necessary) (See attachment summary) Name(s) and Signature(s) of Inspector(s) Agency/OfficelPhone and Fax Numbers Date Harold Messenger GW//919-791-4200/7 � / /''jRRC / 7Chad Coburn /. _ f RRO WQ//919 791-4200/ r) 1 ! ! /-/ 61Uer Signature of Management Q A Reviewer Agency/Office/Phone and Fax Numbers Date EPA Form 3560-3 (Rev 9-94) Previous editions are obsolete. Page # 1 NPDES yr/mo/day Inspection "type 3I NCG020019 I11 t2I 06/07/12 I17 is IWI Section D: Summary of Finding/Comments (Attach additional sheets of narrative and checklists as necessary) None of the analytical monitoring required by the permit was being performed. No records were kept for qualitative monitoring. Copy of permit was on site, but was of 1992 vintage. Page # 2 Michael F. Easley, Governor William G. Ross Jr., Secretary North Carolina Department of Environment and Natural Resources Alan W. Klimek, PA". Director Division of Watcr Quality February 7, 2005 Betty J Redmond Wade Moore Equipment Company PO Box 546 Louisburg, NC 27549 Subject: NPDES Stormwater Permit Coverage Renewal Wade Moore Equipment Company COC Number NCG020019 Franklin County Dear Permittee: In response to your renewal application for continued coverage under general permit NCG020000 the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. Please review the new permit to familiarize yourself with the changes in the reissued permit. The general permit authorizes discharges of stormwater and some types of wastewater. You must meet the provisions of the permit for the types of discharges present at your facility. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983, The following information is included with your permit package: • A new Certificate of Coverage • A copy of General Stormwater Permit NCG020000 • A copy of a Technical Bulletin for the general permit • Five copies of Discharge Monitoring Report (DMR) Forms - wastewater and stormwater • Five copies of Qualitative Monitoring Report Form Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law, rule, standard, ordinance, order, judgment, or decree. If you have any questions regarding this permit package please contact Aisha Lau of the Central Office Stormwater Permitting Unit at (919) 733-5083, ext.578. Sincerely, for Alan W. Klimek, P.E. cc: Central Files Stormwater & General Permits Unit Files Raleigh Regional Office One NorthCarolina Aidurally North Carolina Division of Water Qualily 1617 Mail Smice Center Raleigh, NC 27699-1617 Phone (919) 733-7015 Customer Service lntemet: h2o.enr.state.nc.uslsulstormwater.html 512 N. Salisbury St. Raleigh, NC 27604 FAX (919) 733-9612 1-877-623-6748 An Equal OpportunitylAffirmahve Action Employer — 50% Recycled110% Post Consumer Paper STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCG020019 STORMWATER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Wade Moore Equipment Company is hereby authorized to discharge stormwater and to operate treatment systems and discharges associated with mine dewatering wastewater and process wastewater from a facility located at Wade Moore Equipment Company Fleming Pit Louisburg Franklin County to receiving waters designated as TAR RIVER, a class WS-IV;NSW stream in the Tar -Pamlico River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts I, Il, III, IV, V, and VI of General Permit No. NCG020000 as attached. This certificate of coverage shall become effective February 7, 2005. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day February 7, 2005 for Alan W. Klimek, P.E., Director Division of Water Quality By Authority of the Environmental Management Commission r_-, wtate of North Carolina Department of Environment Al • and Natural Resources Division of Water Quality .lames B. Hunt, Jr., Governor Bill Holman, Secretary NCDENR Kerr T. Stevens, Director NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES December 17, 1999 BETTY J. REDMOND WADE MOORE EQUIPMENT COMPANY P. O. BOX 546 LOUISBURG. NC 27549 Subject: Reissue - NPDES Stormwater Permit Wade Moore Equipment Company COC Number NCG020019 Franklin County Dear Permittee: In response to your renewal application for continued coverage under general permit NCG020000, the Division of Water Quality (DWQ) is forwarding herewith the reissued stormwater general permit. This permit is reissued pursuant to the requirements of North Carolina General Statute 143-215.1 and the Memorandum of Agreement between the state of North Carolina and the U.S. Environmental Protection Agency, dated December 6, 1983. The following information is included with your permit package * A copy of general stormwater permit NCG020000 * Five copies of the Analytical Monitoring form and five copies of the Qualitative Monitoring form * A copy of a Technical Bulletin on this permit which outlines permit components and addresses frequently asked questions * A Certificate of Coverage for your facility * DWQ fee schedule Your coverage under this general permit is not transferable except after notice to DWQ. The Division may require modification or revocation and reissuance of the Certificate of Coverage. This permit does not affect the legal requirements to obtain other permits which may be required by DENR or relieve the permittee from responsibility for compliance with any other applicable federal, state, or local law rule, standard, ordinance, order, judgment, or decree. Please note that in 1998 Senate Bill 1366 established changes to the permit fee structure for DWQ permits effective January I, 1999. This change requires that you pay an annual fee to assure continued coverage under this permit. You will be invoiced for this fee beginning next year. A copy of the current fee schedule is included with this letter. If you have any questions regarding this permit package please contact Tony Evans of the Central Office Stormwater and General Permits Unit at (919) 733-5083, ext. 584 Sincerely, lj��ll_' ' li,-L'6L for Kerr T. Stevens Director, Division of Water Quality cc: Central Files ,_Raleigh Regional Office ; 1617 Mail Service Center, Raleigh, North Carolina 27699-1617 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper f STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT AND NATURAL RESOURCES DIVISION OF WATER QUALITY GENERAL PERMIT NO. NCG020000 CERTIFICATE OF COVERAGE No. NCG020019 STORMWATER AND PROCESS WASTEWATER DISCHARGES NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, WADE MOORE EQUIPMENT COMPANY is hereby authorized to discharge stormwater and to operate or continue operation of treatment systems and discharges associated with mine dewatering and process wastewater from a facility located at WADE MOORE EQUIPMENT COMPANY FLEMING PIT LOUISBURG FRANKLIN COUNTY to receiving waters designated as the Tar River in the Tar - Pamlico River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, Il, III, IV, V, and VI of General Permit No. NCGO20000 as attached. This certificate of coverage shall become effective December 17, 1999. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day December 17, 1999. for Kerr T. Stevens, Director Division of Water Quality By Authority of the Environmental Management Commission ii State of North Carolina Department of Environment, Health and Natural Resources Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary A. Preston Howard, Jr., P.E., Director Betty J. Redman Wade Moore Equipment Company P 0 Box 546 Louisburg, NC 27549 Dear Mr. Redman: June 11, 1993 JUN 16 1993 Subject: General Permit No. Ylg-PO WkL RO Fleming Pit COC NCG020019 Franklin County In accordance with your application for discharge permit received on August 28, 1992, we are forwarding herewith the subject certificate of coverage to discharge under the subject state - NPDES general permit. This permit is issued pursuant to the requirements of North Carolina General Statute 143-215 .1 and the Memorandum of Agreement between North Carolina and the US Environmental Protection agency dated December 6, 1983. If any parts, measurement frequencies or sampling requirements contained in this permit are unacceptable to you, you have the right to request an individual permit by submitting an individual permit application. Unless such demand is made, this certificate of coverage shall be final and binding. Please take notice that this certificate of coverage is not transferable except after notice to the Division of Environmental Management. The Division of Environmental Management may require modification or revocation and reissuance of the certificate of coverage. This permit does not affect the legal requirements to obtain other permits which may be required by the Division of Environmental Management or permits required by the Division of Land Resources, Coastal Area Management Act or any other Federal or Local governmental permit that may be required. If you have any questions concerning this permit, please contact Mr. Steve Ulmer at telephone number 919/733- 5083. cc: , SincereI origin Signed By coleen H. Sullins A. Preston Howard, Jr., P. E. Raleigh Regional Office P.Q. Box 29535, Raleigh, North Carolina 27626-0535 Telephone 919-733-5083 FAX 919-733-9919 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper k STATE OF NORTH CAROLINA DEPARTMENT OF ENVIRONMENT, HEALTH, AND NATURAL. RESOURCES DMSION OF ENVIRONMENTAL MANAGEMENT STORMWATER, MINE DEWATERING, AND/OR OVERFLOW FROM PROCESS WATER RECYCLE SYSTEMS DISCHARGES In compliance with the provision of North Carolina General Statute 143-215.1, other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Federal Water Pollution Control Act, as amended, Wade Moore Equipment Company is hereby authorized to construct and operate additional settling ponds, continue operation of a treatment system consisiting of tailing ponds and rock check dams for mine dewatering and recycle systems process wastewater overflow with the discharges of treated wastewater and stormwater from a facility located at Fleming Pit SR 1600, 1.5 miles from NC Hwy 56 east of Louisburg Louisburg Franklin County to receiving waters designated as the Tar River in the Tar -Pamlico River Basin in accordance with the effluent limitations, monitoring requirements, and other conditions set forth in Parts 1, 1I,111 and IV of General Permit No. NCG020000 as attached. This Certificate of Coverage shall become effective June 11, 1993. This Certificate of Coverage shall remain in effect for the duration of the General Permit. Signed this day June 11, I993. Original Signed By Coleerl H. Sullins A. Preston Howard, Jr., P.E., Director Division of Environmental Management By Authority of the Environmental Management Commission SD— .J' •..J r Sand Pi >osl }> 8 M .272 n I i ✓ if ' it f . n -- � a ✓1 f � sr ^: f tilk t S\J r i Y •r if y ill 1 r' Ir �. + l645 rr I�f nY st � 'i7 14 ❑ i J _ / : .y . •C; y� is-e9 �y - . o LP t \l4 WADC 493 3092 2'3T < 3091 SOC PRIOFMW PROJECT:. Yes No X . •r %19 E0 If Yes, SOC No. -F -L To: Permits and Engineering Unit Water Quality Section Attention: {Steve Ulmerl Date May 21 ,1993 NPDES STAFF REPORT AND RECOMMENDATION County Franklin Permit No. NC G020019 PART I - GENERAL INFORMATION 1. Facility and Address: Wade Moore Equipment Company Fleming Pit PO Box 546 Louisburg , N.C. 27549 2. Date of Investigation: May 20 , 1993 3. Report Prepared by: Michael Wicker 4. Persons Contacted and Telephone Number: Wade Moore 919-496- 3794 5. Directions to Site: Hwy 56 east from Louisburg to SR 1600 River Road , turn right , pit 2 miles on right 6. Discharge Point s), List for all discharge points: Latitude: 36004'20" Longitude:78°16'02" Attach a USGS map extract and indicate treatment facility site and discharge point on map. U.S.G.S. Quad No. C25SE U.S.G.S. Quad Name Louisburg 7. Site size and expansion area consistent with application ? —X Yes No If No, explain: 8. Topography (relationship to flood plain included): site slopes eastward toward Buffalo Creek and Tar River eastern most pit below flood plain, berm holds flooding off site 9. Location of nearest dwelling: over 400 ft. 10.. Receiving stream or affected surface waters: Tar River/Buffalo Creek a. Classification: WS-V NSW SOC PRIOFY PROJECT: If Yes, SOC No. Yes No -0 b. River Basin and Subbasin No.: Tar River 030301 C. Describe receiving stream features and pertinent downstream uses: discharges to Tar River - downstream of Town of Louisburg WWTP 7Q10 sum 16.7 cfs PART II - DESCRIPTION OF DISCHARGE AND TREATMENT WORKS 1. a. Volume of Wastewater to be permitted: N/A MGD(Ultimate Design Capacity) b. What is the current permitted capacity of the Waste Water Treatment facility? N/A C. Actual treatment capacity of the current facility (current design capacity)? designed to hold 10 yr. storm w/o discharge d. Date(s) and construction activities allowed by previous Authorization to Construct issued in the previous two years: N/A e. Please provide a description of existing or substantially constructed wastewater treatment facilities: approximately 15 acres of tailings ponds , rock check dams f. Please provide a description of proposed wastewater treatment facilities: enlarged berm area, settling ponds designed for 10 yr storm capacity, emergency spillway designed for 25 yr. storm flow in excess of 10 yr., rock check dams g. Possible toxic impacts to surface waters: N/A h. Pretreatment Program (POTWs only): N/A in development approved should be required not needed 2. Residuals handling and utilization/disposal scheme: N/A a. If residuals are being land applied, please specify DEM permit no. Residual Contractor Telephone No. b. Residuals stabilization: PSRP e , SOC PRIORJW PROJECT: Yes No 0 If Yes, SOC No. ._ PFRP c. Landfill: Other d. Other disposal/utilization scheme (Specify): 3. Treatment plant classification (attach completed rating sheet): N/A 4. SIC Code(s): 1442 Wastewater Code(s) of actual wastewater, not particular facilities i.e.., non -contact cooling water discharge from a metal plating company would be 14, not 56. Primary 42 Secondary 41 _43_ Main Treatment Unit Code: 50 0 0 0 PART III - OTHER PERTINENT INFORMATION 1. Is this facility being constructed with Construction Grant Funds or are any public monies involved. (municipals only)? N/A 2. Special monitoring or limitations (including toxicity) requests: N/A 3. Important SOC, JOC or Compliance Schedule dates: (Please indicate) N/A Date Submission of Plans and Specifications Begin Construction Complete Construction 4. Alternative Analysis Evaluation: Has the facility evaluated all of the non -discharge options available. Please provide regional perspective for each option evaluated. Spray Irrigation: N/A system is operated as nondischarge the majority of time , all drainage retained below 10 yr storm Connection to Regional Sewer System: N/A Subsurface: N/A Other disposal options: 5. Other Special Items: PART IV - EVALUATION AND RECOMMENDATIONS The existing Fleming Pit consists of sand dredging , mining, dewatering , and recycling activities. The site drains to several settling ponds and storage capacity onsite contains all runoff below the 10 year storm. A berm on the lower side protects the site from flooding by the Tar River and Buffalo Creek. This berm is to be extended upon expansion of the mining SOC PRI04W PROJECT: Yes No —* If Yes, SOC No. area. The facility operates under Mining Permit #35-1 from the Land Quality Section. This permit is currently being renewed. A new settling pond with emergency spillway is under review by Land Quality. The operations at the Fleming Pit appear to employ best managemant practices to control stormwater runoff. All drainage goes to settling ponds with adequate retention time. The Raleigh Regional Office recommends COC NCG020019 for coverage under the General Stormwater NPDES G020000 for mining operations be issued to Wade Moore Equipment Co. for stormwater discharges, recycling activities, and dewatering activities at their Fleming Pit site. Signature of report preparer Water Qua ity Regional Supervisor Z , r �3 D to LABU RG QUADRANGLE NORTH CAROLINA—FRANKLIN CO. 4p 7.5 MINUTE SERIES (TOPOGRAPHIC) "U ,q6 CEIVU VILLr fa mi 78°15' 17'30 2 210 000 FEET 745 J 36°07': ' Oakwood- `„ t .� '`,• i — K Gem l u lI •/ �� /�� Landingllu ;;1.✓ i ` i J �' _ _ low fwy� do Rad 00 I `1; 9 B M 214 860 00 _ \•, ) ti . \ _ i u �` ) FEET , , f! /••� � V l %High. 1 .'t, • ��I J .{ :�% _.. i !'+f I �, i• �' J .` I 1��' II • .� �•` .� - , off' /'� i rr-� �. � ,r'�-' �' ,? ` 11 �\\ . � ��' �%'� t :Z 414, ` i00 too- ` ,.. / f it - ,.'�•- J �� l lI 1 •��A��, )r��. 4, 1 \�, •�I' ii�lq' 'i � `r`� � �`;' Y/ K r/ 250� 3998 � f Ga 'n 1.. ;111 ' - . •r •.j .., �i. n �r� _ �� t1C � [J }�� 1' /..`�/-- ` . r10 4 V N I ll ',9'. q!` 161Yi ! •�.' • ` ti ! -- f _�i ( ^ -.. '-�--' - ��_ 1421 Q k' • Sewage%ABM 146 �� I 79 97 'r - 'j Goii Course .5' L'�� ' — ! -' ;III r • t � i , � \ Sand Pi i f --�•-•r - rY-- 5�� m State of North CAina J Department of Environment, Health and Natural Resources Al r4i � Division of Environmental Management James B. Hunt, Jr., Governor Jonathan B. Howes, Secretary E N A. Preston Howard, Jr., P.E., Director May 5, 1993 RECEIVED t5.�� pow s MAY U 7 f99, ' Ms. Betty Jo Redmond � ��� ;rigs Wade Moore Equipment Co. P.O. Box 546 a��G �.� a` a(_-,,DEH1YR-RAL RO Louisburg, NC 27549 *� f o�J p' G c �tbject: NOl Application �j " DES: NCG020019 U f"t`"� C4'Franklin County Dear Ms, Redmond: T (o„ V a. r This letter is to acknowledge receipt of your application dated August 27, 1992 for coverage under General Permit for mine dewatering activities. The permit number highlighted above has been assigned to the subject facility. By copy of this letter, we are requesting that our Regional Office Supervisor prepare a staff report and recommendations regarding this discharge. If you have questions regarding this matter, please contact Steve Ulmer at (919) 733- 611131 W < v u 5-k_� �Si ncez'el }, �u,�C leen Sullins, P.E. Supervisor, NPDES Group cc: Raleigh Regional Office (with attachments) Permits and Engineering Unit _ I Central Fifes ` �—t- � 3 -5 G•if� c[, ye r �a.. �l.wv � If �.�� sG r, f) G✓ r a RO. Box 29 3eRalei9 h North ralina 27626-0535 Telephone hone 919-733-7015 FAX 919-733-2496 An Equal Opportunity Affirmative Action Employer 50% recycled/ 10% post -consumer paper -r, 7l ivor<— Jp .-f- �Slr1C ^ Cc � 511 o,..n.- (O ul r rna Ann: 1r:Y USE ONLY �rK �� � ' rya■ NATIONAL POLLUTANT DISCHARGE ELIMINATION SYSTEM NOTICE OF INTENT REQUESTING COVERAGE UNDER THE MINING ACTIVITIES GENERAL NPDES PERMIT NCG020000 �7 Complete this Notice of intent (NOl) and mail to the following address North Carolina Division of Environmental Management Water Quality Section, NPDES Group, P,O. Box 29535 Raleigh, North Carolina, 27626-0535 The NO1 must be accompanied with a general permit filing fee of $400.00. The check should be made out to the North Carolina Department of Environment, Health, and Natural Resources. Facility Owner/Operator information: Name:, wade Moore Equipment Company Address: P. 0. Box 546 City: Louisburg State: North Carolina . Zip. 27549 Phone:( 919) 496-3794 _ Name: Fleming Pit Address: p• 0• Box 546 City: Louisburg State: N-C. Zip: 27549 County: Franklin Phone f_919)496-3794 T _ Physical Location Information: (Street address, state road number, distance and direction from roadway intersection, g-Dj attach a copy of a county map or USGS quad with the locations of the facility marked on the map.) Located on SR1600-1.5 miles from NC56 East of Louisbuca {Agency use only: Latitude Longitude NOZ 02 PAGE 1 Type of minerals mined at this facility: Sand Standard Industrial Classification (SIC CODE). 14 (for activity for which the facility is primarily engaged) This is an existing facility or a _proposed facility. If props sd daat�op@ration is to begin Discharges are to (name of receiving waters or, if to a separate storm sewer system, name of the separate storm sewer system) A. Does this facility have any NPDES Permits? -_yes .xno If yes, NPDES No. B. Are vehicle maintenance activities occurring on site? _ yes cx no C. Are mine dewatering discharges occurring? _ yes x no D. Are discharges of overflows from process wastewater treatment systems occurring? ___-yes-.Kno If yes, complete the following on the wastewater treatment system: 1. Please describe the type of process used to treat and/or recycle the process wastewater. Give design specifics (i.e. design volume, retention time, surface area, etc.). Existing treatment facilities should be described in detail and design criteria or operational data should be provided (including calculations) to ensure that the facility can comply with requirements of the General Permit. NOTE: Construction of any wastewater treatment facilities require submission of three (3) sets of plans and specifications along with their application. Design of treatment facilities must comply with requirements 15A NCAC 2H .0138. If construction of wastewater treatment facilities applies to the discharge of process wastewater, include three sets of plans and specifications with this application. 2. Does this facility employ chemical additives to flocculate suspended solids? ,yes —no If yes, please state the name, manufacturer and the quantity of average daily usage of the chemical additive. 3. Does this facility overflow only during -rainfall events exceeding the 10-year, 24-hour rainfall event? _yes _no 1� E. Does this facility employ any best management practices for stormwater control? ,_yes x no If yes, please describe NO-1 02 PAGE 2 F. Number of discharge points Mine Dewatering Stormwater ; Process Wastewater Overflows T; Please provide short narrative description of discharges water used in processing_ recycled in settling ponds _ I hereby request coverage under the referenced General Permit. I understand that coverage Under this permit will constitute the permit requirements for the discharge(s) and is enforceable in the same manner as an individual permit. I agree to abide by the following as a part of coverage under this General Permit 1. 1 agree to abide by the approved Mining Permit for this mining activity. ( A copy of the valid mining permit must be attached to this request. 2. t agree.to not.discharge any sanitary wastewater from this mining activity except under the provisions of another NPDES permit specifically issued therefore. 3. 1 agree that bulk storage of petroleum products and other chemicals shall have adequate protection so as to contain all spills on the site. . 4. 1 agree that solid wastes will be disposed of in accordance with N.C. statutes and rules governing solid waste disposal. 5. 1 agree that maintenance activities for vehicles and heavy equipment will be performed so as to not result in contamination of the surface or ground waters. 1 agree to abide by the provisions as listed above and recognize that the provisions are to be considered as enforceable requirements of the General Permit. I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, compiete, and accurate. A I 1� 199 signature U date Betty Jo Redmond uhi-1�--) name of person signing above (printed or typed) title North Carolina General Statute 143-215.6B (i) provides that: Any person who knowingly makes any false statement, representation, or certification in any application, record, report, plan or other document filed or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $10,000, or by imprisonment not to exceed six months, or by both. (1 B U.S.C. Section 1001 provides a punishment by a fine of not more than $10,000 or imprisonment not more than 5 years, or both, for similar offense.) NOT 02 PAGE 3