Loading...
HomeMy WebLinkAboutNCG020001_COMPLETE FILE - HISTORICAL_20150706STORMWATER DIVISION CODING SHEET NCG PERMITS PERMIT NO. DOC TYPE �S, HISTORICAL FILE ❑ MONITORING REPORTS DOC DATE ❑ o ( ap)5 YYYYMMDD AGAIM NUF NCDENR (T North Carolina Department of Environment and Natural Resource Rat McCrory Governor DAVID LEE -ENVIRONMENTAL SUPERVISOR WAKE STONE PO Box 190 KNIGHTDALE, NC 27545 Dear Mr. Lee: Donald R. van der Vaart Secretary July 6, 2015 Subject: Multimedia Compliance Inspection Triangle Quarry Lee County Department of Environment and Natural Resources staff.from the Raleigh Regional Office conducted a multimedia compliance inspection of Triangle Quarry on June P, 2015 for permits and programs administered by the following Divisions: Division of Air Quality Division of Energy, Division of Water Division of Waste Mineral, and Land Resources Management Resources We appreciate your cooperation during the inspection and hope that you have enjoyed the benefit of our initiative to provide a single inspector capable of handling multiple areas of environmental compliance at your facility. The results of each applicable inspection and any associated response actions or necessary corrective measures are detailed in the inspection letters/reports attached to this transmittal sheet. If you have any questions regarding this multimedia inspection or the results of each program inspection, please contact the Raleigh Regional Office at (919) 791-4200 and ask to speak with the appropriate Division staff. Thank you for your cooperation. Copies: DAQ RRO Files DEMLR PRO Files DWR RRO Files DWM RRO Files NCDBNR Raleigh Regional Office 1628 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 3800 Barrett Drive, Raleigh North Carolina 27609 Phone:919.791-42001Fax: (919)788-7159 An Equal Opportunity l Affirmative Aclion Employer .- Made In par[ with recycled paper North Carolina Department of Environment and Natural Resources, Division of Energy, Mineral, and Land Resources, Land Quality Section MINE INSPECTION REPORT X❑ PERMITTED MINE SITE ❑ UNPERMITTED MINE SITE 1. MINE NAME: Triangle Quarry 2. MINE LOCATION. , 222 Star Ln Cary 3. COUNTY: Wake 4. RIVER BASIN: Neuse 5. CASE: 6. OPERATOR: Wake Stone Corp. 7. ADDRESS: PO Box 190 Knightdale, 27545 ,NC 8. MINING PERMIT #: 92-10 ❑ NIA 9. PERMIT EXPIRATION DATE: 03/30/2021 ❑ NIA 10. PERSON(S) CONTACTED AT SITE: I I. PICTURES? X❑ Yes ❑ No TAKEN BY: 12. TYPE OF INSPECTION: ❑ A. Initial Inspection (Unpermitted Mine Sites) 1. Size of affected land: ac. (attach sketch map) 2. How was this area measured? Measured by: X❑ B. Routine Inspection (Permitted Mine Sites) Q C. Follow-up Inspection 13. Date of last inspection: 06/03/2015 14. Any mining since that date? X ❑ Yes ❑ No If yes, cite evidence of such mining activity: Mining ongoing 15. Was mine operating at time of inspection? X❑ Yes ❑ No If yes, explain: ^ Mining at time of inspection _ 16. Is the mine in compliance with the Operating Conditions of the Permit? X❑ Yes ❑ No ❑ NIA If no, explain: 17. Is the mine in compliance with the Reclamation Conditions of the Permit? X❑ Yes No ❑ NIA If no, explain: 18. Is there any off -site damage? A. ❑ Yes B.X ❑ No C. ❑ None observed If A, describe the type and severity of the damage: If B or C, is there potential for offsite damage? ❑ Yes X ❑ No Explain: 19. Corrective measures needed and/or taken: 20. Other recommendations and comments: As discussed during the inspection walk through, vegetating the access road along the West side of the project near TST-1 & TST-2 would allow for the analytical and qualitative sample requirements to be suspended. The responsible parties should request in writing or email that these_ samples points be removed from the ge_rmit with the justification for such _ 21. Is the Annual Reclamation Report f/- map accurate? X ❑ Yes ❑ No (Explain) ❑ Not Reviewed ❑ N/A 22. Follow-up inspection needed? ❑ Yes X ❑ No Proposed date 23. No. of additional pages of Inspection Report 0 24. Copy of Report sent to operator INSPECTED BY: Thad Valentine, John Holley, Lori Phillips, Cheng Zhang, Andrew Martin ( Multi Media Group) - DATE 06/08/2015 Telephone No: (919) 791-4200_ Copy to file Copy to operator Copy to Mining Specialist NC®ENR North Carolina Department of Environment and Natural Resources Pat McCrory Donald R. van der Vaart Governor Secretary June 17, 2015 Mr. Theodore Bratton, CEO Wake Stone Corporation P.O. Box 190 Knightdale, NC 27545 Subject: NPDES Stormwater Compliance Evaluation Inspection Certificate of Coverage No. NCG020001 Wake Stone Corporation — Triangle Quarry Wake County Dear Mr, Bratton: Staff from the Department of Environmental and Natural- Resources conducted a stormwater inspection on June 3, 2015, as part of a multimedia inspection of your facility. The assistance provided by Mr. John Bratton, Mr. David Lee, Mr. Cole Atkins, and Mr. Paul Pierce during the inspection was greatly appreciated. The inspection report is attached. findings during the inspection were as follows: 1. Certificate of Coverage (COC) No. NCG020001 under NPDES general permit NCG020000 was issued to Wake Stone Corporation -- Triangle Quarry to discharge stormwater runoff and process wastewater to Crabtree Creek, a Class-C NSW stream, in the Neuse River Basin. 2. The facility has developed and implemented a stormwater pollution prevention plan (SPPP). A review of the plan indicated that it covered -many components required by the general permit. The following deficiencies were noted: • Employee training has not been conducted and documented; • The plan has not been reviewed or updated annually; • The plan lacks a summary or table of secondary containment. 3. Qualitative monitoririg)has been conducted as required by the permit at outfalls that were active. It was noted that analytical monitoring was not conducted in 2011 and 2014. There have been no discharges from Stormwater Discharge Outfalls (SDOs) 005, and 006 in the past years, because of the relatively small drainage areas and settling basins at each outfall. It is recommended that the facility continue the effort to sample at these two outfalls. If no discharges occur during a semi-annual period, report "no flow" on the annual monitoring report. Sampling at.SDO 003 must be conducted semi-annually, as water from the big pond regularly discharges through a rock dam at the outfall. 4. SDOs 005, 006, 003, and the skimmer basins (effluent goes to SDO 003) were observed NCDENR Raleigh Regional Office 1628 Mail Service Center, Raleigh, North Carolina 27699-1617 Location: 3800 Barrett Drive, Raleigh North Carolina 27609 Phone; 919-79142001 Fax'. (919) 788-7159 An Equal Opportunity 1 Affirmative Ac#ion Employer— Made in part with recycled paper Page 2 of 2 IS G during the inspection and found to be in good condition. The facility does not discharge process wastewater outside the mining boundary. Please respond in writing regarding Items 2 and 3 within 60 days of receipt of this letter. If you have any questions regarding the attached report or any of the findings, please contact Cheng Zhang at 919-791-4200 (or email: cheng zhang@ncdenr. ov). Sincerely, Cheng Zhang Environmental Senior Specialist Raleigh Regional Office Enclosure: Compliance Evaluation Inspection Form cc-. Central Files RRO 5WP files Compliance Inspection Report Permit: NGG020001 Effective: 01/01/10 Expiration: 12/31114 Owner: Wake Stone Corp SOC: Effective: Expiration: Facility: Triangle Quarry County: Wake 222 Star Ln Region: Raleigh Cary NC 27513 Contact Person: Theodore D Bratton Title: Phone: 919-266-1100 Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Inspection Date: 06/03/2015 Primary Inspector: Cheng Zhang Secondary Inspector(s): Certification: Entry Time: 09:00AM C.,I-�, e,�J-ukj- Phone: Exit Time: 02:OOPM Phone: 919-791-4200 6 /r � / �-o"j - Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: Mining Activities Stormwater Discharge COC Facility Status: ❑ Compliant Not Compliant Question Areas: Storm Water (See attachment summary) Page: 1 Permit: NCG020001 Owner - Facility: Waite Stone Corp Inspection Date: 0610312015 Inspection Type : Compliance Evaluation Reason for visit: Routine Stormwater Pollution Prevention Plan Yas No NA NE Does the site have a Stormwater Pollution Prevention Plan? ®❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? ® ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ ® ❑ # Has the facility evaluated feasible alternatives to current practices? ® ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ❑ ❑ ❑ # Does the Plan include a BMP summary? E ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? E ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? 0 ❑ ❑ ❑ # Does the facility provide and document Employee Training? ❑ E ❑ ❑ # Does the Plan include a list of Responsible Party(s)? 0 ❑ ❑ ❑ # Is the Plan reviewed and updated annually? ❑ ®❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? 0 ❑ ❑ ❑ Comment: EmDlovee trainina has not been conducted and documented. The plan has not been reviewed and updated annually. The plan was reviewed -and undated on June 1_. 2015. The plan lacks a table or summa of secondary containment. Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? E ❑ ❑ ❑ Comment: Qualitative monitoring h�R Been conducted at all outfalls semi-annually. Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? ❑ ®❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ S ❑ ❑ Comment: No analytical samples were taken in 2011 and 2014. . It is understood that discharges from SDO 006 and 005 are rare because the relatively small drainage areas and settling basins at the outfalls(Only overflows over the berms/dams cause discharges). The facility shall continue the effort to collect samples at these locations after representative storm events. If no discharge occurs in a semi-annual period, record "no flow" on the annual_ monitoring report._ Samolinq at SDO 003 must be conducted semi-annually, as water from the bia pond reaularl discharges through a rock dam at the outfall. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑ Page: 3 permit: NCG020001 Owner - Facility: Wake Stone Corp Inspection Data: 0610312015 Inspection Type: Compliance Evaluation Reason for Visit: Routine # Were all outfalls observed during the inspection? M ❑ ❑ ❑ # If the facility has representative outfall status, is it property documented by the Division? ❑ 110 ❑ # Has the facility evaluated all illicit (non stormwater) discharges? ® ❑ ❑ ❑ Comment: O_utfails 005, 006, and 003 were observed during the inspection. They were maintained and accessible. Page: 4 Page 1 of 4 NC®ENP NORTH CAROLINA DEPARTMENT OF ENVIRONMENT& NATURAL RESOURCES DIVISION OF WASTE MANAGENIEN (DWN4) IiAZARDOUS WASTE SECTION (IIWS)1 COMPLIANCE BRANCH 1. Facility Information: 2. Facility Contact: 3. HWS-Inspectors: 4. Date/Time of Investieation: Date of Report: 5. Participants: 6. Purpose of Inspection: 7. Re art: RCRA INSPECTION REPORT Wake Stone Corporation 222 Star Lane Cary, NC 27513 EPA ID#: NCS000002246 Mr, David Lee, Chief Geologist/ Environmental Supervisor Phone: 919-266-1100, Email: davidlee@wakestonecorp.com Mr. Andrew Martin, NC HWS-Environmental Senior Specialist June 3, 2015 Arrived: 9:30 am — Departed: 1:30pm June 12, 2015 - Prepared By: Andrew Martin Thad Valentine, NCDENR Land Quality Section Lori Phillips, NCDENR Air Quality Section Cheng Zhang, NCDENR Water Quality Section Jack Garvey Compliance Evaluation Inspection On June 3, 2015, I and the three NCDENR colleagues listed above conducted a multimedia inspection at the Wake Stone Corporation quarry located at 222 Star Lane in Cary, NC. The facility operates one shift and is staffed with thirty-five employees. Buildings located on the site include an office area, quality control lab, training room, storage building, and maintenance building. Rock is mined from an open pit and brought to a processing area where it is crushed into small pieces by primary and secondary crushers. A tour of facility operations was conducted during the visit. Waste Streams at the facility includes used oil, used antifreeze, batteries, mercury containing lamps, aerosol cans, and solvent wipes. Batteries are exchanged for core recycling once they are generated through interstate batteries. Used oil is accumulated in above ground storage tanks and in several smaller containers. The facility contracts with Safety-Kleen for collection of used oil for recycling and maintains receipts. A parts washer is located within the maintenance shop area and is maintained by Safety-Klecn. The parts washer uses Non -Hazardous Safety-Kleen Premium Gold solvent. The used solvent rags are stored within a closed container and are sent off for laundering. No empty aerosol cans or used lamps were observed Andrew Martin, QEP- NC Hazardous Waste Section Oftice: 217 W. Janes Street, 1646 Mail Service Cenier, Raleigh, NC 27699 Phone: (919) 270-3507 Email: Andrew.Martinrancdenr.gov Page 3 of 4 262. Additionally, LQGs and SQGs must obtain a site EPA Identification Number before offering hazardous waste for off -site transport and disposal. Guidance documents for hazardous waste generators can be found at: http://l2ortal.nrdeiir.org/web/wm/hw/Technical It is a reminder that any container that is used to store or contain used oil must be labeled with the words "Used Oil." a%4x-- *.4, 6/12/2015 Andrew Martin, QEP / DATE NC HWS-COMPLIANCE BRANCH cc: Jenny Patterson, Eastern Area Compliance Supervisor Central Office Files Andrew Martin, QEf - NC Hazordous Waste Section Office: 217 W. Jones Street, 1646 Mail Service Center, Raleigh, NC 27699 Phone: (919) 270-3507 Email: Andrew.Martin4 ncdenr.gov SENI US MAIL FACILITY REPRESENTATIVE NORTH CAROLINA DIVISION OF AIR QUALITY Inspection Report Date: 06/03/2015 Facility Data Wake Stone Corporation - Triangle Quarry 222 Star Lane Cary, NC 27513 Lat: 35d 50.2020m Long: 78d 46.1540m SIC: 1423 / Crushed And Broken Granite NAICS: 212313 / Crushed and Broken Granite Mining and Quarrying Facility Contact Paul Pierce Superintendent (919) 677-0050 Comments: Inspector's Signature: Date of Signature: Contact Data Authorized Contact Theodore Bratton CEO (919) 266-1100 Technical Contact David Lee Geologist/Environmental Supervisor (919)266-1100 Raleigh Regional Office Wake Stone Corporation - Triangle Quarry NC Facility ID 9200409 County/FIPS: Wake/l83 Permit Data Permit 04386 / R15 Issued 8/30/2013 Expires 7/31/2021 Classification Small Permit Status Active Current Permit Application(s) None Program Applicability SIP MACT Part 63: Subpart ZZZZ NSPS: Subpart 000 Compliance Data Inspection Date 06/03/2015 Inspector's Name Lori Ann Phillips Operating Status Operating Compliance Code Compliance - inspection Action Code FCE On -Site Inspection Result Compliance I Total Actual emissions in TONSIYEAR: I TSP S02 NOX VOC CO PM10 * HAP 2012 1.53 0.1000 2.57 0.2100 0.5500 0.7900 --- 2007 11.66 0.2300 3.53 0.2900 0.7600 4.35 --- Five Year Violation History: None Date Letter Type Rule Violated Performed Stack Tests since last FCE: None Date Test Results Test Method(s) * Hip -hest HAP Emitted Violation Resolution Date Sources Tested (1) DIRECTIONS TO FACILITY: Wake Stone Corporation -- Triangle Quarry is located at 222 Star Lane, Cary, Wake County. From the RRO, take I40 West to Harrison Ave. Turn right onto Harrison Ave. towards Umstead Park. Turn left onto Star Lane just before the entrance to Umstead Park Reedy Creek entrance. Follow In compliance. The facility contact is aware of this requirement. The most recent permit was issued in August of 2013 and the next Emissions Inventory will not be due for a number of years. A.3. EQUIPMENT REPORTING - The Permittee shall maintain on -site an equipment list and a plant (or flow) diagram of all equipment covered under this permit. Permit designates specific data to be maintained on each piece of equipment. These documents should bearthe date when the current list and diagram were revised. Documentation shall be provided to the Regional Supervisor, Division of Air Quality, for any required performance testing within seven days of a written request. Permittee may install new or relocate existing non -primary crushing nonmetallic mineral processing equipment or so long as such equipment does not change the primary crushing rated capacity of the facility. The Permittee shall provide written notification to the Regional Supervisor, Division of Air Quality, including a revised equipment list and a plant layout or flow diagram, each time non -primary crushing nonmetallic mineral processing equipment is installed or relocated at a facility. This notification shall be submitted at least 15 days before the equipment is installed at the facility unless otherwise approved by the Director. Non -primary crushing nonmetallic mineral processing equipment includes all non -primary crushers, screens, conveyors and loadout bins. In compliance. There have been no changes to the plant's equipment list since the last inspection. The equipment list and plant diagram were last updated in 2012; these documents contained all required information. A.4. PARTICULATE CONTROL REQUIREMENT - As required by 15A NCAC 2D .0510, the following requirements apply: a. The Permittee of a sand, gravel, or crushed stone operation shall not cause, allow, or permit any material to be produced, handled, transported, or stockpiled without taking measures to reduce to a minimum any particulate matter from becoming airborne to prevent exceeding the ambient air quality standards beyond the property line for particulate matter, both PMio and total suspended particulates. b. Fugitive dust emissions from sand, gravel, or crushed stone operations shall be controlled by 15A NCAC 21) .0540 "Particulates from Fugitive Dust Emission Sources." c. The Permittee of any sand, gravel, or crushed stone operation shall control process -generated emissions: i. From crushers with wet suppression; and ii. From conveyors, screens, and transfer points such that the applicable opacity standards in 15A NCAC 21) .0521 Control of Visible Emissions," or 15A NCAC 2D .0524 "New Source Performance standards" are not exceeded. In compliance. No particulate matter or visible emissions were observed at this facility. Triangle Quarry uses wet suppression to control VE and there was evidence that the spray system was working correctly and doing its job. A.5. The primary crusher is a jaw crusher rated at 1620 tons per hour at 16 inch crusher setting per the manufacturer's specification as submitted. Any change from this crusher definition, other than like -for like, will require a permit application to be submitted. The purpose of this stipulation is to characterize the primary crusher and not limit production. In compliance. The primary crusher has not been replaced or modified. A.6. VISIBLE EMISSIONS CONTROL REQUIREMENT - As required by 15A NCAC 2D .0521, visible emissions from the emission sources, manufactured after July 1, 1971, shall not be more than 20 percent opacity when averaged over a six -minute period. In compliance. Visible emissions were not noted at the time of the inspection. A.7. VISIBLE EMISSIONS CONTROL REQUIREMENT - As required by 15A NCAC 2D .0521, visible emissions from the emission sources, manufactured as of July 1, 1971, shall not be more than 40 percent opacity when averaged over a six -minute period. In compliance. All equipment B.15 Clean Air Act Section l l2(r) Requirements - If the Permittee is required to develop and register a risk management plan pursuant to Section 112(r) of the Federal Clean Air Act, then the Permittee is required to register this plan in accordance with 40 CFR Part 68. Not Applicable — This program does not apply to this facility. (VIin INSIGNIFICANT 1 EXEMPT SOURCES: The facility has no listed insignificant/exempt emissions sources. There is one small waste oil heater used for comfort heating in the maintenance/shop area. This heater may be added to the exempt equipment list during the next permit renewal or modification. (IX) 112 R: The facility has not triggered this set of rules. (X) COMPLIANCE HISTORY: There were no NOVs or other compliance issues listed in the IBEAM database for this facility. (XI) PERFORMANCE TEST REVIEW: No testing has been done in the last 5 years. (XII) EMISSIONS INVENTORY REVIEW: Changes in reported PM and PMio emissions from 2007 to 2012 are due to differences in calculating the facility -wide PM emissions as documented in the emissions inventory report. (XIII) CONCLUSIONS AND RECOMMENDATIONS: At the time of the inspection, the facility appeared to be in compliance with the permitting requirements. Recommend inspection within two years.