HomeMy WebLinkAboutNCG020001_COMPLETE FILE - HISTORICAL_20150706STORMWATER DIVISION CODING SHEET
NCG PERMITS
PERMIT NO.
DOC TYPE
�S, HISTORICAL FILE
❑ MONITORING REPORTS
DOC DATE
❑ o ( ap)5
YYYYMMDD
AGAIM NUF
NCDENR (T
North Carolina Department of Environment and Natural Resource
Rat McCrory
Governor
DAVID LEE -ENVIRONMENTAL SUPERVISOR
WAKE STONE
PO Box 190
KNIGHTDALE, NC 27545
Dear Mr. Lee:
Donald R. van der Vaart
Secretary
July 6, 2015
Subject: Multimedia Compliance Inspection
Triangle Quarry
Lee County
Department of Environment and Natural Resources staff.from the Raleigh Regional Office conducted a
multimedia compliance inspection of Triangle Quarry on June P, 2015 for permits and programs
administered by the following Divisions:
Division of Air Quality
Division of Energy,
Division of Water
Division of Waste
Mineral, and Land
Resources
Management
Resources
We appreciate your cooperation during the inspection and hope that you have enjoyed the benefit of our
initiative to provide a single inspector capable of handling multiple areas of environmental compliance at
your facility. The results of each applicable inspection and any associated response actions or necessary
corrective measures are detailed in the inspection letters/reports attached to this transmittal sheet.
If you have any questions regarding this multimedia inspection or the results of each program inspection,
please contact the Raleigh Regional Office at (919) 791-4200 and ask to speak with the appropriate
Division staff. Thank you for your cooperation.
Copies: DAQ RRO Files
DEMLR PRO Files
DWR RRO Files
DWM RRO Files
NCDBNR Raleigh Regional Office
1628 Mail Service Center, Raleigh, North Carolina 27699-1617
Location: 3800 Barrett Drive, Raleigh North Carolina 27609
Phone:919.791-42001Fax: (919)788-7159
An Equal Opportunity l Affirmative Aclion Employer .- Made In par[ with recycled paper
North Carolina Department of Environment and Natural Resources,
Division of Energy, Mineral, and Land Resources, Land Quality Section
MINE INSPECTION REPORT
X❑ PERMITTED MINE SITE ❑ UNPERMITTED MINE SITE
1. MINE NAME: Triangle Quarry 2. MINE LOCATION. , 222 Star Ln Cary
3. COUNTY: Wake 4. RIVER BASIN: Neuse 5. CASE:
6. OPERATOR: Wake Stone Corp.
7. ADDRESS: PO Box 190 Knightdale, 27545
,NC
8. MINING PERMIT #: 92-10 ❑ NIA 9. PERMIT EXPIRATION DATE: 03/30/2021
❑ NIA
10. PERSON(S) CONTACTED AT SITE:
I I. PICTURES? X❑ Yes ❑ No TAKEN BY:
12. TYPE OF INSPECTION:
❑ A. Initial Inspection (Unpermitted Mine Sites)
1. Size of affected land: ac. (attach sketch map)
2. How was this area measured? Measured by:
X❑ B. Routine Inspection (Permitted Mine Sites)
Q C. Follow-up Inspection
13. Date of last inspection: 06/03/2015
14. Any mining since that date? X ❑ Yes ❑ No If yes, cite evidence of such mining activity:
Mining
ongoing
15. Was mine operating at time of inspection? X❑ Yes ❑ No If yes, explain: ^ Mining at time of
inspection
_
16. Is the mine in compliance with the Operating Conditions of the Permit? X❑ Yes ❑
No ❑ NIA
If no, explain:
17. Is the mine in compliance with the Reclamation Conditions of the Permit? X❑ Yes
No ❑ NIA
If no, explain:
18. Is there any off -site damage? A. ❑ Yes B.X ❑ No C. ❑ None observed
If A, describe the type and severity of the damage:
If B or C, is there potential for offsite damage? ❑ Yes X ❑ No Explain:
19. Corrective measures needed and/or taken:
20. Other recommendations and comments: As discussed during the inspection walk through, vegetating the
access road along the West side of the project near TST-1 & TST-2 would allow for the analytical and qualitative
sample requirements to be suspended. The responsible parties should request in writing or email that these_ samples
points be removed from the ge_rmit with the justification for such _
21. Is the Annual Reclamation Report f/- map accurate? X ❑ Yes ❑ No (Explain) ❑ Not Reviewed ❑
N/A
22. Follow-up inspection needed? ❑ Yes X ❑ No Proposed date
23. No. of additional pages of Inspection Report 0 24. Copy of Report sent to operator
INSPECTED BY: Thad Valentine, John Holley, Lori Phillips, Cheng Zhang, Andrew Martin ( Multi Media
Group) -
DATE 06/08/2015
Telephone No: (919) 791-4200_
Copy to file Copy to operator Copy to Mining Specialist
NC®ENR
North Carolina Department of Environment and Natural Resources
Pat McCrory Donald R. van der Vaart
Governor Secretary
June 17, 2015
Mr. Theodore Bratton, CEO
Wake Stone Corporation
P.O. Box 190
Knightdale, NC 27545
Subject: NPDES Stormwater Compliance Evaluation Inspection
Certificate of Coverage No. NCG020001
Wake Stone Corporation — Triangle Quarry
Wake County
Dear Mr, Bratton:
Staff from the Department of Environmental and Natural- Resources conducted a stormwater inspection
on June 3, 2015, as part of a multimedia inspection of your facility. The assistance provided by Mr.
John Bratton, Mr. David Lee, Mr. Cole Atkins, and Mr. Paul Pierce during the inspection was greatly
appreciated. The inspection report is attached. findings during the inspection were as follows:
1. Certificate of Coverage (COC) No. NCG020001 under NPDES general permit NCG020000
was issued to Wake Stone Corporation -- Triangle Quarry to discharge stormwater runoff and
process wastewater to Crabtree Creek, a Class-C NSW stream, in the Neuse River Basin.
2. The facility has developed and implemented a stormwater pollution prevention plan (SPPP).
A review of the plan indicated that it covered -many components required by the general
permit. The following deficiencies were noted:
• Employee training has not been conducted and documented;
• The plan has not been reviewed or updated annually;
• The plan lacks a summary or table of secondary containment.
3. Qualitative monitoririg)has been conducted as required by the permit at outfalls that were
active. It was noted that analytical monitoring was not conducted in 2011 and 2014.
There have been no discharges from Stormwater Discharge Outfalls (SDOs) 005, and
006 in the past years, because of the relatively small drainage areas and settling basins
at each outfall. It is recommended that the facility continue the effort to sample at these
two outfalls. If no discharges occur during a semi-annual period, report "no flow" on
the annual monitoring report. Sampling at.SDO 003 must be conducted semi-annually,
as water from the big pond regularly discharges through a rock dam at the outfall.
4. SDOs 005, 006, 003, and the skimmer basins (effluent goes to SDO 003) were observed
NCDENR Raleigh Regional Office
1628 Mail Service Center, Raleigh, North Carolina 27699-1617
Location: 3800 Barrett Drive, Raleigh North Carolina 27609
Phone; 919-79142001 Fax'. (919) 788-7159
An Equal Opportunity 1 Affirmative Ac#ion Employer— Made in part with recycled paper
Page 2 of 2
IS G
during the inspection and found to be in good condition. The facility does not discharge
process wastewater outside the mining boundary.
Please respond in writing regarding Items 2 and 3 within 60 days of receipt of this letter. If you
have any questions regarding the attached report or any of the findings, please contact Cheng Zhang at
919-791-4200 (or email: cheng zhang@ncdenr. ov).
Sincerely,
Cheng Zhang
Environmental Senior Specialist
Raleigh Regional Office
Enclosure: Compliance Evaluation Inspection Form
cc-. Central Files
RRO 5WP files
Compliance Inspection Report
Permit: NGG020001 Effective: 01/01/10 Expiration: 12/31114 Owner: Wake Stone Corp
SOC: Effective: Expiration: Facility: Triangle Quarry
County: Wake 222 Star Ln
Region: Raleigh
Cary NC 27513
Contact Person: Theodore D Bratton Title: Phone: 919-266-1100
Directions to Facility:
System Classifications:
Primary ORC:
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 06/03/2015
Primary Inspector: Cheng Zhang
Secondary Inspector(s):
Certification:
Entry Time: 09:00AM
C.,I-�, e,�J-ukj-
Phone:
Exit Time: 02:OOPM
Phone: 919-791-4200
6 /r � / �-o"j -
Reason for Inspection: Routine Inspection Type: Compliance Evaluation
Permit Inspection Type: Mining Activities Stormwater Discharge COC
Facility Status: ❑ Compliant Not Compliant
Question Areas:
Storm Water
(See attachment summary)
Page: 1
Permit: NCG020001 Owner - Facility: Waite Stone Corp
Inspection Date: 0610312015 Inspection Type : Compliance Evaluation Reason for visit: Routine
Stormwater Pollution Prevention Plan
Yas No NA NE
Does the site have a Stormwater Pollution Prevention Plan?
®❑ ❑ ❑
# Does the Plan include a General Location (USGS) map?
® ❑ ❑ ❑
# Does the Plan include a "Narrative Description of Practices"?
❑ ❑ ❑
# Does the Plan include a detailed site map including outfall locations and drainage areas?
❑ ❑ ❑
# Does the Plan include a list of significant spills occurring during the past 3 years?
❑ ❑ ® ❑
# Has the facility evaluated feasible alternatives to current practices?
® ❑ ❑ ❑
# Does the facility provide all necessary secondary containment?
❑ ❑ ❑
# Does the Plan include a BMP summary?
E ❑ ❑ ❑
# Does the Plan include a Spill Prevention and Response Plan (SPRP)?
E ❑ ❑ ❑
# Does the Plan include a Preventative Maintenance and Good Housekeeping Plan?
0 ❑ ❑ ❑
# Does the facility provide and document Employee Training?
❑ E ❑ ❑
# Does the Plan include a list of Responsible Party(s)?
0 ❑ ❑ ❑
# Is the Plan reviewed and updated annually?
❑ ®❑ ❑
# Does the Plan include a Stormwater Facility Inspection Program?
❑ ❑ ❑
Has the Stormwater Pollution Prevention Plan been implemented?
0 ❑ ❑ ❑
Comment: EmDlovee trainina has not been conducted and documented.
The plan has not been reviewed and updated annually. The plan was reviewed -and undated on
June 1_. 2015.
The plan lacks a table or summa of secondary containment.
Qualitative Monitoring Yes No NA NE
Has the facility conducted its Qualitative Monitoring semi-annually? E ❑ ❑ ❑
Comment: Qualitative monitoring h�R Been conducted at all outfalls semi-annually.
Analytical Monitoring Yes No NA NE
Has the facility conducted its Analytical monitoring? ❑ ®❑ ❑
# Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ S ❑ ❑
Comment: No analytical samples were taken in 2011 and 2014. .
It is understood that discharges from SDO 006 and 005 are rare because the relatively small
drainage areas and settling basins at the outfalls(Only overflows over the berms/dams cause
discharges). The facility shall continue the effort to collect samples at these locations after
representative storm events. If no discharge occurs in a semi-annual period, record "no flow" on
the annual_ monitoring report._
Samolinq at SDO 003 must be conducted semi-annually, as water from the bia pond reaularl
discharges through a rock dam at the outfall.
Permit and Outfalls
Yes No NA NE
# Is a copy of the Permit and the Certificate of Coverage available at the site? 0 ❑ ❑ ❑
Page: 3
permit: NCG020001 Owner - Facility: Wake Stone Corp
Inspection Data: 0610312015 Inspection Type: Compliance Evaluation Reason for Visit: Routine
# Were all outfalls observed during the inspection? M ❑ ❑ ❑
# If the facility has representative outfall status, is it property documented by the Division? ❑ 110 ❑
# Has the facility evaluated all illicit (non stormwater) discharges? ® ❑ ❑ ❑
Comment: O_utfails 005, 006, and 003 were observed during the inspection. They were maintained and
accessible.
Page: 4
Page 1 of 4
NC®ENP
NORTH CAROLINA DEPARTMENT OF ENVIRONMENT& NATURAL
RESOURCES
DIVISION OF WASTE MANAGENIEN (DWN4) IiAZARDOUS
WASTE SECTION (IIWS)1 COMPLIANCE BRANCH
1. Facility Information:
2. Facility Contact:
3. HWS-Inspectors:
4. Date/Time of
Investieation:
Date of Report:
5. Participants:
6. Purpose of Inspection:
7. Re art:
RCRA INSPECTION
REPORT
Wake Stone Corporation
222 Star Lane
Cary, NC 27513
EPA ID#: NCS000002246
Mr, David Lee, Chief Geologist/ Environmental Supervisor
Phone: 919-266-1100, Email: davidlee@wakestonecorp.com
Mr. Andrew Martin, NC HWS-Environmental Senior
Specialist
June 3, 2015 Arrived: 9:30 am — Departed: 1:30pm
June 12, 2015 - Prepared By: Andrew Martin
Thad Valentine, NCDENR Land Quality Section
Lori Phillips, NCDENR Air Quality Section
Cheng Zhang, NCDENR Water Quality Section
Jack Garvey
Compliance Evaluation Inspection
On June 3, 2015, I and the three NCDENR colleagues listed above conducted a multimedia inspection at
the Wake Stone Corporation quarry located at 222 Star Lane in Cary, NC. The facility operates one shift
and is staffed with thirty-five employees. Buildings located on the site include an office area, quality
control lab, training room, storage building, and maintenance building. Rock is mined from an open pit
and brought to a processing area where it is crushed into small pieces by primary and secondary
crushers.
A tour of facility operations was conducted during the visit. Waste Streams at the facility includes used
oil, used antifreeze, batteries, mercury containing lamps, aerosol cans, and solvent wipes. Batteries are
exchanged for core recycling once they are generated through interstate batteries.
Used oil is accumulated in above ground storage tanks and in several smaller containers. The facility
contracts with Safety-Kleen for collection of used oil for recycling and maintains receipts. A parts
washer is located within the maintenance shop area and is maintained by Safety-Klecn. The parts washer
uses Non -Hazardous Safety-Kleen Premium Gold solvent. The used solvent rags are stored within a
closed container and are sent off for laundering. No empty aerosol cans or used lamps were observed
Andrew Martin, QEP- NC Hazardous Waste Section
Oftice: 217 W. Janes Street, 1646 Mail Service
Cenier, Raleigh, NC 27699
Phone: (919) 270-3507 Email:
Andrew.Martinrancdenr.gov
Page 3 of 4
262. Additionally, LQGs and SQGs must obtain a site EPA Identification Number before offering
hazardous waste for off -site transport and disposal. Guidance documents for hazardous waste
generators can be found at: http://l2ortal.nrdeiir.org/web/wm/hw/Technical
It is a reminder that any container that is used to store or contain used oil must be labeled with the
words "Used Oil."
a%4x-- *.4, 6/12/2015
Andrew Martin, QEP / DATE
NC HWS-COMPLIANCE BRANCH
cc:
Jenny Patterson, Eastern Area Compliance Supervisor
Central Office Files
Andrew Martin, QEf - NC Hazordous Waste Section
Office: 217 W. Jones Street, 1646 Mail Service
Center, Raleigh, NC 27699
Phone: (919) 270-3507 Email:
Andrew.Martin4 ncdenr.gov
SENI US MAIL
FACILITY REPRESENTATIVE
NORTH CAROLINA DIVISION OF
AIR QUALITY
Inspection Report
Date: 06/03/2015
Facility Data
Wake Stone Corporation - Triangle Quarry
222 Star Lane
Cary, NC 27513
Lat: 35d 50.2020m Long: 78d 46.1540m
SIC: 1423 / Crushed And Broken Granite
NAICS: 212313 / Crushed and Broken Granite Mining and Quarrying
Facility Contact
Paul Pierce
Superintendent
(919) 677-0050
Comments:
Inspector's Signature:
Date of Signature:
Contact Data
Authorized Contact
Theodore Bratton
CEO
(919) 266-1100
Technical Contact
David Lee
Geologist/Environmental
Supervisor
(919)266-1100
Raleigh Regional Office
Wake Stone Corporation - Triangle Quarry
NC Facility ID 9200409
County/FIPS: Wake/l83
Permit Data
Permit 04386 / R15
Issued 8/30/2013
Expires 7/31/2021
Classification Small
Permit Status Active
Current Permit Application(s) None
Program Applicability
SIP
MACT Part 63: Subpart ZZZZ
NSPS: Subpart 000
Compliance Data
Inspection Date 06/03/2015
Inspector's Name Lori Ann Phillips
Operating Status Operating
Compliance Code Compliance - inspection
Action Code FCE
On -Site Inspection Result Compliance
I Total Actual emissions in TONSIYEAR: I
TSP
S02
NOX
VOC
CO
PM10
* HAP
2012
1.53
0.1000
2.57
0.2100
0.5500
0.7900
---
2007
11.66
0.2300
3.53
0.2900
0.7600
4.35
---
Five Year Violation History: None
Date Letter Type Rule Violated
Performed Stack Tests since last FCE: None
Date Test Results Test Method(s)
* Hip -hest HAP Emitted
Violation Resolution Date
Sources Tested
(1) DIRECTIONS TO FACILITY: Wake Stone Corporation -- Triangle Quarry is located at 222 Star Lane,
Cary, Wake County. From the RRO, take I40 West to Harrison Ave. Turn right onto Harrison Ave. towards
Umstead Park. Turn left onto Star Lane just before the entrance to Umstead Park Reedy Creek entrance. Follow
In compliance. The facility contact is aware of this requirement. The most recent permit was
issued in August of 2013 and the next Emissions Inventory will not be due for a number of
years.
A.3. EQUIPMENT REPORTING - The Permittee shall maintain on -site an equipment list and a plant
(or flow) diagram of all equipment covered under this permit. Permit designates specific data to
be maintained on each piece of equipment. These documents should bearthe date when the current
list and diagram were revised. Documentation shall be provided to the Regional Supervisor,
Division of Air Quality, for any required performance testing within seven days of a written
request. Permittee may install new or relocate existing non -primary crushing nonmetallic mineral
processing equipment or so long as such equipment does not change the primary crushing rated
capacity of the facility. The Permittee shall provide written notification to the Regional
Supervisor, Division of Air Quality, including a revised equipment list and a plant layout or flow
diagram, each time non -primary crushing nonmetallic mineral processing equipment is installed or
relocated at a facility. This notification shall be submitted at least 15 days before the equipment is
installed at the facility unless otherwise approved by the Director. Non -primary crushing
nonmetallic mineral processing equipment includes all non -primary crushers, screens, conveyors
and loadout bins. In compliance. There have been no changes to the plant's equipment list
since the last inspection. The equipment list and plant diagram were last updated in 2012;
these documents contained all required information.
A.4. PARTICULATE CONTROL REQUIREMENT - As required by 15A NCAC 2D .0510, the
following requirements apply:
a. The Permittee of a sand, gravel, or crushed stone operation shall not cause, allow, or permit
any material to be produced, handled, transported, or stockpiled without taking measures to
reduce to a minimum any particulate matter from becoming airborne to prevent exceeding the
ambient air quality standards beyond the property line for particulate matter, both PMio and
total suspended particulates.
b. Fugitive dust emissions from sand, gravel, or crushed stone operations shall be controlled by
15A NCAC 21) .0540 "Particulates from Fugitive Dust Emission Sources."
c. The Permittee of any sand, gravel, or crushed stone operation shall control process -generated
emissions:
i. From crushers with wet suppression; and
ii. From conveyors, screens, and transfer points
such that the applicable opacity standards in 15A NCAC 21) .0521 Control of Visible Emissions,"
or 15A NCAC 2D .0524 "New Source Performance standards" are not exceeded.
In compliance. No particulate matter or visible emissions were observed at this facility.
Triangle Quarry uses wet suppression to control VE and there was evidence that the spray
system was working correctly and doing its job.
A.5. The primary crusher is a jaw crusher rated at 1620 tons per hour at 16 inch crusher setting per the
manufacturer's specification as submitted. Any change from this crusher definition, other than
like -for like, will require a permit application to be submitted. The purpose of this stipulation is to
characterize the primary crusher and not limit production. In compliance. The primary crusher
has not been replaced or modified.
A.6. VISIBLE EMISSIONS CONTROL REQUIREMENT - As required by 15A NCAC 2D .0521,
visible emissions from the emission sources, manufactured after July 1, 1971, shall not be more
than 20 percent opacity when averaged over a six -minute period. In compliance. Visible
emissions were not noted at the time of the inspection.
A.7. VISIBLE EMISSIONS CONTROL REQUIREMENT - As required by 15A NCAC 2D .0521,
visible emissions from the emission sources, manufactured as of July 1, 1971, shall not be more
than 40 percent opacity when averaged over a six -minute period. In compliance. All equipment
B.15 Clean Air Act Section l l2(r) Requirements - If the Permittee is required to develop and register a risk
management plan pursuant to Section 112(r) of the Federal Clean Air Act, then the Permittee is required to register
this plan in accordance with 40 CFR Part 68.
Not Applicable — This program does not apply to this facility.
(VIin INSIGNIFICANT 1 EXEMPT SOURCES: The facility has no listed insignificant/exempt emissions
sources. There is one small waste oil heater used for comfort heating in the maintenance/shop area. This
heater may be added to the exempt equipment list during the next permit renewal or modification.
(IX) 112 R: The facility has not triggered this set of rules.
(X) COMPLIANCE HISTORY: There were no NOVs or other compliance issues listed in the IBEAM
database for this facility.
(XI) PERFORMANCE TEST REVIEW: No testing has been done in the last 5 years.
(XII) EMISSIONS INVENTORY REVIEW: Changes in reported PM and PMio emissions from 2007 to 2012
are due to differences in calculating the facility -wide PM emissions as documented in the emissions
inventory report.
(XIII) CONCLUSIONS AND RECOMMENDATIONS:
At the time of the inspection, the facility appeared to be in compliance with the permitting requirements.
Recommend inspection within two years.