February 13, 2020
Ms. Renee Culler, Sr. Environmental Engineer
CNA Holding, LLC
2525 Blacksburg Road
Grover, NC 28073
Subject: Compliance Bioassay Results
Celanese — Shelby Plant
NPDES Permit No. NC0004952
Cleveland County
Dear Ms. Culler:
Enclosed is a copy of the Compliance Sampling Inspection for the inspection conducted
at the subject facility on December 10, 2019, by Ori Tuvia and Maria Schutte. The results for the
bioassay sampling was a Pass.
The report should be self-explanatory; however, should you have any questions
concerning this report, please do not hesitate to contact Ori Tuvia at (704) 235-2190, or at
ori.tuviaAmcdenn gov.
Sincerely,
DocuSigned by:
C---
�--BB057A2DE017498...
Ori Tuvia, Environmental Engineer
Mooresville Regional Office
Division of Water Resources, DEQ
Cc: NPDES, MRO Files (Laserfiche)
State of North Carolina I Environmental Quality I Water Resources I Water Quality Regional Operations
Mooresville Regional Office 1 610 East Center Avenue, Suite 3011 Mooresville, North Carolina 28115
704 663 1699
Division of Water Resources
December 19. 20113
M€MOftANDUM
To: Corey Basinger
Water Quallty Regionai Operations, MRO
Through: I~indyA, Moore
Supervisor, Aquatic Tuxieology Bra ndh (A713�
From- Lorimar S. Henning Ail
Environrrientai5pedallst 1, Aquatic 7oxicology Branch (ATB)
Subte€t. Whole effluent toxicity test results
CNA Holdings, Inc. {Tlcona Facility)
NPDES Pi�rrT1it 4 NCW(4952
Cleveland Count}
The aquatic tax icity test using Row- prapurtional composite samples of effluent dischareed from
the CNA Holdings, Inc. (Ticona Facility) k3s been compl4�trsd. CNA Holdings, Inc. (Tiaona Facility)
has a Permitted e#fluern discharge of 0,45 million gallons Per day (MG D� entering Buffalo Creak
(7010of 20 US). Whole effluentsampleswere collected on December 10 and December 1� by
Ori Tuvla and facility representative Randy Turner for use in a chronic Ceriodaphnia dubig pass -
fail toxkity test. The test passed. Toxichytest information follows_
Test Type 3-Brood Cerrodaphnia dribia ch ronir, pass -fall
Test Result
Pass
Test Concern#rations
2.13%
Control Surykval
100%
Control Mean Reproductlon
2125 neonates
Test Treatment Surviva@
100%
Treatrn-ent Mean Reproduction
21.67 neonates
First Sample pH
8,29 SU
First Sample Cunductivity
402A mlcromhos/cm
First Sample Total ResWual Chlorine
0.1-5 mg/L
Second Sample pH
5,38 SU
Second Sample Conductivlty
409-0 micromhos/cm
Second Sample Total Residual Chlorine
0-01 mg/L
Test results for the above Sam Pies indicate that the effluent would not be predicted to have
water quality impacts- These sarnples were split and tested by FTT Envlronmimta1, Inc. The
chronic Ceriadaph Ou dubio pass/fa iI test run by M Environmental, Inc_ resulted ire a pass -
Please contact us if you have arty questions or If further effluent toxicity monktoring is desired.
e may be reached at 019) 743-$W1_
Basin: Broad
cc; Wes Bell (MRO)