Loading...
HomeMy WebLinkAboutSW3191205_SuppEZ-2018-Version-2.1.1_2/11/2020SUPPLEMENT-EZ COVER PAGE FORMS LOADED PROJECT INFORMATION roject Name R4Surface roject Area acoastal Wetland Area Water Area (a Windsong Subdivision 53.7 in 5 Ils this project High or Low Density? High 6 1 Does this protect use an off -site SCM? No COMPLIANCE WITH 02H .1003(4) 7 Width of vegetated setbacks provided feet 100' & 200' 8 Will the vegetated setback remain vegetated? Yes 9 Is BUA other that as listed in .1 0034 c-d out of the setback? Yes 10 Is streambank stabilization proposed on this project? No NUMBER AND TYPE OF SCMs: 11 Infiltration System 0 12 Bioretention Cell 0 13 Wet Pond 0 14 Stormwater Wetland 0 15 Permeable Pavement 0 16 Sand Filter 3 17 Rainwater Harvesting RWH 0 18 Green Roof 0 19 Level Spreader -Filter Strip LS-FS 0 20 Disconnected Impervious Surface (DIS) 0 21 Treatment Swale 0 22 Dry Pond 0 23 StormFilter 0 24 Silva Cell 0 25 Bayfilter 0 26 Filterra 0 FORMS LOADED DESIGNER CERTIFICATION 27 Name and Title: Tim Foley, Vice President 28 Organization: Henson Foley Design 29 Street address: 8712 Lindholm Dr #202A 30 City, State, Zip: Huntersville, NC 28078 31 Phone numbers : 704 875-1615 32 Email: tim@hensonfoley.com Certification Statement: I certify, under penalty of law that this Supplement-EZ form and all supporting information were prepared under my direction or supervision; that the information provided in the form is, to the best of my knowledge and belief, true, accurate, and complete; and that the engineering plans, specifications, operation and maintenance agreements and other supporting information are consistent with the information provided here. \\\UIII III„,// /, Essa��%' SEAL —_ 23557 ], ° 0 a F�GIN���o TyY oo�Fo\`�� Seal Signature of Designer Date DRAINAGE AREAS 1 Is this a high density project? Yes 2 If so number of drainage areas/SCMs 3 3 Is all/part of this project subject to previous rule versions? No FORMS LOADED A INFORMATION Entire Site 1 2 3 M Sand Filter Sand Filter Sand Filter inroject s ft 170019 sf 95630 sf 43735 sf 30917 sf on subdivided lots (subject to s ft 7permitting) 170,019 sf 95,630 sf 43,735 sf 30,917 sf outside of subdivided lots (subject to s 0 sf 0 sf 0 sf Osf 8 1 Offsite -total area (sq ft 68,552 sf 4,374 sf 43,916 sf 20 262 sf 9 Offsite BU(sq ft 0 sf 0 sf 0 sf 0 sf 10 Breakdown of new BUA outside subdivided lots: Parking (sq ft 41,126 sf 22,434 sf 13,241 sf 5,451 sf Sidewalk (sq ft 0 sf 0 sf 0 sf 0 sf Roof (sq ft 84,357 sf 43,857 sf 23,400 sf 17,100 sf Roadway s ft 50,437 sf 29,338 sf 12,735 sf 8,364 sf Future (sq ft 0 sf 0 sf 0 sf 0 sf Other, please specify in the comment box below (sq ft 11 New infiltrating permeable pavement on subdivided lots (sq ft 0 sf 0 sf 0 sf 0 sf 12 New infiltrating permeable pavement outside of Isubdivided lots (sq ft 0 sf 0 sf 0 sf 0 sf 13permitting) Exisitng BUA that will remain (not subject to s ft 0 sf 0 sf 0 sf 0 sf 14 Existing BUA that is already permitted (sq ft 0 sf 0 sf 0 sf 0 sf 15 Existing BUA that will be removed (sq ft 0 sf 0 sf 0 sf 0 sf 16 Percent BUA 0 sf 0 sf 0 sf 0 sf 17 Design storm inches 3 in 3 in 3 in 3 sf 18 1 Design volume of SCM cu ft 78007 cf 40882 cf 21328 cf 15797 cf 19 1 Calculation method for design volume Hydro CAD Hydro CAD Hydro CAD Hydro CAD ADDITIONAL INFORMATION 20 Please use this space to provide any additional information about the drainage area(s): SAND FILTER MDC FROM 02H .1050 3 Is the SCM sized to treat the SW from all surfaces at build -out? Yes Yes Yes 4 Is the SCM located away from contaminated soils? Yes Yes Yes 5 What are the side slopes of the SCM (H:V)? 3:1 3:1 3:1 6 Does the SCM have retaining walls, gabion walls or other engineered side slopes? No No No 7 Are the inlets, outlets, and receiving stream protected from erosion (10- 1year storm)? Yes Yes Yes 8 Is there an overflow or bypass for inflow volume in excess of the design volume? Yes Yes Yes 9 What is the method for dewatering the SCM for maintenance? Pump (preferred) Pump (preferred) Pump (preferred) 10 If applicable, will the SCM be cleaned out after construction? Yes Yes Yes 11 Does the maintenance access comply with General MDC (8)? Yes Yes Yes 12 Does the drainage easement comply with General MDC (9)? Yes Yes Yes 13 If the SCM is on a single family lot, does (will?) the plat comply with General MDC (10)? Yes Yes Yes 14 Is there an O&M Agreement that complies with General MDC (11)? Yes Yes Yes 15 Is there an O&M Plan that complies with General MDC (12)? No No No 16 Does the SCM follow the device specific MDC? Yes Yes Yes 17 Was the SCM designed by an NC licensed professional? Yes Yes Yes ISAND FILTER MDC FROM 02H .1056 18 SHWT elevation (fmsl) 19 Type of sand filter (open or closed) Open Open Open 20 If closed, will the filter will be pre -cast or pour -in -place? 21 If closed, top of grate elevation (fmsl) 22 Is this sand filter designed to attenuate peak flows? Yes Yes Yes Sediment Chamber 23 Volume that can be retained in the sediment chamber (cubic feet) 2096 cf 910 cf 776 cf 24 Will there be a permanent pool in the sediment chamber? No No No 25 Bottom of the sediment chamber (fmsl) 553.00 558.00 553.00 26 Area of the sediment chamber (square feet) 2096 sf 910 sf 776 sf 27 Physical depth of the sediment chamber (inches) 12 in 12 in 12 in 28 Ponding depth in the sediment chamber, above any permanent pool (inches) 12 in 12 in 12 in 29 Elevation of top of weir between chambers (fmsl) 554 559 554 Sand Chamber 30 Volume that can be retained in the sand chamber (cubic feet) 1200 cf 500 cf 575 cf 31 Bottom of the sand chamber (fmsl) 550.50 555.50 550.50 32 Area of the sand chamber (square feet) 480 sf 200 sf 230 sf 33 Physical depth of the sand chamber (inches) 30 in 30 in 30 in 34 Ponding depth in the sand chamber, above any permanent pool (inches) 0 in 0 in 0 in 35 Elevation of the bypass device (fmsl) 557 562 556 36 Type of bypass device Control Structure Control Structure Control Structure 37 Mechanism for distributing flow over the sand surface 38 Sand specification for sand chamber ASTM C33 ASTM C33 ASTM C33 39 Depth above underdrain pipe (inches) 42 in 42 in 42 in 40 Will the media be maintained to drain at least two inches per hour at the sand surface? Yes Yes Yes 41 Is at least one clean -out pipe provided at the low point of each underdrain line? Yes Yes Yes 42 lWill clean -out pipes be capped? Yes Yes Yes ADDITIONAL INFORMATION 43 Please use this space to provide any additional information about the Sand Filter(s): Sand Filter 1 2:13 PM 10/21/2019