Loading...
HomeMy WebLinkAboutWQ0005173_Compliance Evaluation Inspection_20200129DocuSign Envelope ID: 191BDA87-5667-4ED4-8A6D-E33EDE6A4291 ROY COOPER Governor MICHAEL S. REGAN secretary S. DANIEL SMITH Dlreernr NORTH CAROLINA En vrraninga tal Quality February 11, 2020 Doris Speicher Cape Royall Dolphin Association Incorporated 9708 Lord Berkeley Dr Emerald Isle, NC 28594-1812 SUBJECT: Compliance Inspection Report Cape Royall Dolphin WWTP Non -discharge Permit No. WQ0005173 Carteret County Dear Permittee: The North Carolina Division of Water Resources conducted an inspection of the Cape Royall Dolphin WWTP on 1/29/2020. This inspection was conducted to verify that the facility is operating in compliance with the conditions and limitations specified in Non -discharge Permit No. WQ0005173. The findings and comments noted during this inspection are provided in the enclosed copy of the inspection report entitled "Compliance Inspection Report". There were no significant issues or findings noted during the inspection and therefore, a response to this inspection report is not required. If you should have any questions, please do not hesitate to contact Geoff Kegley with the Water Quality Regional Operations Section in the Wilmington Regional Office at 910-796-7215 or via email at geoff.kegley@ncdenr.gov. Sincerely bocuSigned by Toµ 'N,.rr, OA, for 7F141 73B6F 4 6 . Morella Sanc ez- Ing, Regional Supervisor Water Quality Regional Operations Section Wilmington Regional Office Division of Water Resources, NCDEQ Cc: Fortin Contract Service DWR-Laserfiche North Cs{obna Department of Environmeatsd Quaiitp I Division of Water Resources WflmngtonRego naaOffice 1127 CarMaaiDFive Extensen I Wilwngton, North Caroina2S405 °'-\ 910-796-7215 Permit: WQ0005173 SOC: County: Carteret Region: Wilmington Compliance Inspection Report Effective: 03/01/19 Expiration: 02/29/24 Owner: Cape Royall Dolphin Association Incorporated Effective: Expiration: Facility: Cape Royall Dolphin WWTP 304 Cape Fear Loop Contact Person: Doris Speicher Directions to Facility: System Classifications: WW2, Primary ORC: Secondary ORC(s): On -Site Representative(s): Title: Registered Agent Certification: Emerald Isle NC 28594 Phone: 252-354-4656 Phone: Related Permits: WQ0004985 Cape Royall Dolphin Association Incorporated - Cape Royall Dolphin Sewer System WQ0018525 Barnes Environmental Waste and Hauling Inc - Barnes Environmental RLAP Inspection Date: 01/29/2020 Entry Time: 09:30AM Exit Time: 11:OOAM Primary Inspector: Geoff Kegley Phone: Secondary Inspector(s): Reason for Inspection: Routine Inspection Type: Compliance Evaluation Permit Inspection Type: High Rate Infiltration Facility Status: Compliant ❑ Not Compliant Question Areas: Treatment Flow Measurement -Effluent Treatment Flow Measurement -Influent Miscellaneous Questions Treatment Flow Measurement -Water Treatment Treatment Barscreen Use Records Treatment Filters Record Keeping Treatment Activated Sludge Treatment Sludge Storage/Treatment Treatment Clarifiers Treatment Disinfection End Use -Infiltration Treatment Flow Measurement Treatment Return pumps Standby Power Wells (See attachment summary) Page 1 of 7 Permit: WQ0005173 Owner - Facility: Cape Royall Dolphin Association Incorporated Inspection Date: 01/29/2020 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: A routine compliance inspection was performed with the assistance of Dan Fortin and company. Since the last inspection the facility has been sandblasted and recoated and a new generator installed. The system has generally been in compliance with effluent and groundwater monitoring limits except for some erratic TDS and coliform exceedances in monitoring wells. The Division will continue to monitor and evaluate these results. The area's water supply is from an RO system therefore the ORC is adding soda ash routinely to maintain alkalinity. See attached for further notes and comments. Page 2 of 7 Permit: WQ0005173 Inspection Date: 01/29/2020 Owner - Facility: Cape Royall Dolphin Association Incorporated Inspection Type : Compliance Evaluation Reason for Visit: Routine Type Yes No NA NE Reuse (Quality) ❑ Recycle/Reuse ❑ Single Family Drip ❑ Lagoon Spray, LR ❑ Single Family Spray, LR ❑ Activated Sludge Spray, LR ❑ Activated Sludge Spray, HR ❑ Activated Sludge Drip, LR ❑ Infiltration System Treatment Yes No NA NE Are Treatment facilities consistent with those outlined in the current permit? 0 ❑ ❑ ❑ Do all treatment units appear to be operational? (if no, note below.) 0 ❑ ❑ ❑ Comment: Facility has been sandblasted and recoated since last inspection. Treatment Flow Measurement -Influent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ ❑ Is flowmeter operating properly? ❑ ❑ ❑ Does flowmeter monitor continuously? ❑ ❑ ❑ Does flowmeter record flow? ❑ ❑ ❑ Does flowmeter appear to monitor accurately? ❑ ❑ ❑ Comment: Treatment Flow Measurement -Water Use Records Yes No NA NE Is water use metered? ❑ ❑ ❑ Are the daily average values properly calculated? ❑ ❑ 0 ❑ Comment: Treatment Flow Measurement -Effluent Yes No NA NE Is flowmeter calibrated annually? ❑ ❑ ❑ Is flowmeter operating properly? ❑ ❑ ❑ Does flowmeter monitor continuously? ❑ ❑ ❑ Does flowmeter record flow? ❑ ❑ ❑ Does flowmeter appear to monitor accurately? 0 ❑ ❑ ❑ Comment: Calibration sticker not present but ORC provided documentation after inspection. Standby Power Yes No NA NE Is automatically activated standby power available? 0 ❑ ❑ ❑ Page 3 of 7 Permit: WQ0005173 Owner - Facility: Cape Royall Dolphin Association Incorporated Inspection Date: 01/29/2020 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is generator tested weekly by interrupting primary power source? ❑ ❑ ❑ Is generator operable? ❑ ❑ ❑ Does generator have adequate fuel? 0 ❑ ❑ ❑ Comment: New generator recently installed. Auto transfer tested and is operational. Treatment Barscreen Yes No NA NE Is it free of excessive debris? 0 ❑ ❑ ❑ Is disposal of screenings in compliance? 0 ❑ ❑ ❑ Are the bars spaced properly? 0 ❑ ❑ ❑ Is the unit in good condition? 0 ❑ ❑ ❑ Comment: Grinder pumps Treatment Activated Sludge Yes No NA NE Is the aeration mechanism operable? 0 ❑ ❑ ❑ Is the aeration basin thoroughly mixed? ❑ ❑ ❑ Is the aeration equipment easily accessed? ❑ ❑ ❑ Is Dissolved Oxygen adequate? ❑ ❑ ❑ Are Settleometer results acceptable? ❑ ❑ ❑ Is activated sludge an acceptable color? 0 ❑ ❑ ❑ Comment: Regional water supply is from an RO system therefore the ORC is adding soda ash routinely to maintain alkalinity. Treatment Clarifiers Yes No NA NE Are the weirs level? ❑ ❑ ❑ Are the weirs free of solids and algae? ❑ ❑ ❑ Is the scum removal system operational? ❑ ❑ ❑ Is the scum removal system accessible? ❑ ❑ ❑ Is the sludge blanket at an acceptable level? ❑ ❑ ❑ Is the effluent from the clarifier free of excessive solids? ❑ ❑ ❑ Comment Treatment Return pumps Yes No NA NE Are they in place? ❑ ❑ ❑ Are they operational? ❑ ❑ ❑ Comment: Treatment Filters Yes No NA NE Is the filter media present? 0 ❑ ❑ ❑ Is the filter media the correct size and type? ❑ ❑ ❑ Is the air scour operational? 0 ❑ ❑ ❑ Page 4 of 7 Permit: WQ0005173 Owner - Facility: Cape Royall Dolphin Association Incorporated Inspection Date: 01/29/2020 Inspection Type : Compliance Evaluation Reason for Visit: Routine Is the scouring acceptable? ❑ ❑ ❑ Is the clear well free of excessive solids? ❑ ❑ ❑ Is the mud well free of excessive solids and filter media? 0 ❑ ❑ ❑ Does backwashing frequency appear adequate? 0 ❑ ❑ ❑ Comment: Filters do not have auto backwash, therefore it is performed manually on a daily basis. Treatment Sludge Storage/Treatment Yes No NA NE Is the aeration operational? ❑ ❑ ❑ Is the aeration pattern even? ❑ ❑ ❑ If required, are Sanitary "Ts" present in tankage? ❑ ❑ 0 ❑ Comment: Treatment Disinfection Yes No NA NE Is the system working? ❑ ❑ ❑ Do the fecal coliform results indicate proper disinfection? ❑ ❑ ❑ Is there adequate detention time (-30 minutes)? ❑ ❑ ❑ Is the system properly maintained? ❑ ❑ ❑ If gas, does the cylinder storage appear safe? ❑ ❑ ❑ Is the fan in the chlorine feed room and storage area operable? ❑ ❑ ❑ Is the chlorinator accessible? ❑ ❑ ❑ If tablets, are tablets present? 0 ❑ ❑ ❑ Are the tablets the proper size and type? ❑ ❑ ❑ Is contact chamber free of sludge, solids, and growth? ❑ ❑ ❑ If UV, are extra UV bulbs available? ❑ ❑ ❑ If UV, is the UV intensity adequate? ❑ ❑ ❑ # Is it a dual feed system? ❑ ❑ ❑ Does the Stationary Source have more than 2500 Ibs of Chlorine (CAS No. 7782-50-5)? ❑ ❑ ❑ If yes, then is there a Risk Management Plan on site? ❑ ❑ ❑ If yes, then what is the EPA twelve digit ID Number? (1000- If yes, then when was the RMP last updated? Comment: Record Keeping Yes No NA NE Is a copy of current permit available? ❑ ❑ ❑ Are monitoring reports present: NDMR? ❑ ❑ ❑ NDAR? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Are flow rates less than of permitted flow? ❑ ❑ ❑ Page 5 of 7 Permit: WQ0005173 Owner - Facility: Cape Royall Dolphin Association Incorporated Inspection Date: 01/29/2020 Inspection Type : Compliance Evaluation Reason for Visit: Routine Are application rates adhered to? ❑ ❑ ❑ Is GW monitoring being conducted, if required (GW-59s submitted)? ❑ ❑ ❑ Are all samples analyzed for all required parameters? ❑ ❑ ❑ Are there any 2L GW quality violations? ❑ ❑ ❑ Is GW-59A certification form completed for facility? ❑ ❑ ❑ Is effluent sampled for same parameters as GW? ❑ ❑ ❑ Do effluent concentrations exceed GW standards? ❑ ❑ ❑ Are annual soil reports available? ❑ ❑ ❑ # Are PAN records required? ❑ ❑ ❑ # Did last soil report indicate a need for lime? ❑ ❑ ❑ If so, has it been applied? ❑ ❑ ❑ Are operational logs present? ❑ ❑ ❑ Are lab sheets available for review? ❑ ❑ ❑ Do lab sheets support data reported on NDMR? ❑ ❑ ❑ Do lab sheets support data reported on GW-59s? ❑ ❑ ❑ Are Operational and Maintenance records present? ❑ ❑ ❑ Were Operational and Maintenance records complete? ❑ ❑ ❑ Has permittee been free of public complaints in last 12 months? ❑ ❑ ❑ Is a copy of the SOC readily available? ❑ ❑ ❑ No treatment units bypassed since last inspection? ❑ ❑ ❑ Comment: Groundwater monitoring indicates some erratic TDS and coliform exceedances. Discussed with the ORC during the inspection. End Use -Infiltration Yes No NA NE # Is the application High Rate or Low Rate? High Rate Are buffers maintained? ❑ ❑ ❑ Are any supply wells within the CB? ❑ ❑ ❑ Are any supply wells within 250' of the CB? ❑ ❑ ❑ Is municipal water available in the area? ❑ ❑ ❑ Are GW monitoring wells required? 0 ❑ ❑ ❑ Are GW monitoring wells located properly w/ respect to RIB and CB? ❑ ❑ ❑ Are GW monitoring wells properly constructed, including screened interval? ❑ ❑ ❑ Is a usable green area maintained? ❑ ❑ ❑ Is the disposal site acceptable? ❑ ❑ ❑ Is the distribution equipment acceptable? ❑ ❑ ❑ Is the disposal site free of ponding? ❑ ❑ ❑ Is the disposal site free of breakout? ❑ ❑ ❑ Page 6 of 7 Permit: WQ0005173 Owner - Facility: Cape Royall Dolphin Association Incorporated Inspection Date: 01/29/2020 Inspection Type : Compliance Evaluation Reason for Visit: Routine Are the disposal sites free of solids, algae, etc.? Do the records show that the fields are properly maintained? Are the disposal sites free of vegetation? Do any surface water features appear to be adversely impacted by GW discharge? No chemicals or rototiller used to eliminate vegetation, solids, algae, etc.? Comment: • ❑ ❑ ❑ • ❑ ❑ ❑ • ❑ ❑ ❑ ❑❑■❑ ❑❑❑■ Page 7 of 7