Loading...
HomeMy WebLinkAbout20200215 Ver 1_BR-0115_Permit Drawings_20200210North Carolina Department of Transportation Highway Stormwater Program STORMWATER MANAGEMENT PLAN v (Version 2.08; Released April 2018) 1: FOR NCDOT PROJECTS iK WBS Element: 67115.1.1 TIP No.: BR-0115 County(ies): Iredell Page 1 of 1 General Project Information WBS Element: 67115.1.1 TIP Number: BR-0115 Project Type: Bridge Replacement Date: 12/4/2019 NCDOT Contact: David Stutts Contractor / Designer: STV Engineers, Inc. / Shirshant Sharma Address: 1020 Birch Ridge Drive Raleigh, NC 27610 Address: 900 West Trade Street, Ste. 715 Charlotte, NC 28202 Phone: (919) 707-6442 Phone: (704) 816-2556 Email: dstutts@ncdot.gov Email: Shirshant.Sharma@stvinc.com City/Town: Love Valley, NC County(ies): Iredell River Basin(s): Yadkin -Pee Dee CAMA County? No Wetlands within Project Limits? No Project Description Project Length (lin. miles or feet): 0.13 Surrounding Land Use: Rural Residential Proposed Project Existing Site Project Built -Upon Area (ac.) 0.3 ac. 0.3 ac. Typical Cross Section Description: Bridge : Two 10' lanes, 3'11" to the right and 3'11" to the left paved shoulders. Approach: Two 10' lanes, variable paved shoulders. Bridge: Two 10' lanes,1.5' to the right and 1.5' to the left shoulders. Approach: Two 10' lanes, variable shoulders. Annual Avg Daily Traffic (veh/hr/day): Design/Future: 1120 Year: 2040 Existing: 560 Year: 2016 General Project Narrative: (Description of Minimization of Water Quality Impacts) The existing 107', 3 span bridge over Rocky Creek on SR 1595 (Coolbrook Road) is being replaced with 3 span bridge with a span arrangement of 1@30' (21" Cored Slab), 1@70' (24" Cored Slab), and 1@35' (21" Cored Slab). The bridge will have 1.5:1 sloping abutments. The bridge will be superelevated with a 3% slope and with 10' travel lanes with 3'11" to the right and 3'11" to the left shoulders, 27'-10" clear width and 30' OTO width. The existing bridge structure will be removed. Overall drainage patterns will be maintained. There are roadside ditches that flow towards the bridge on both sides of the project. On the end side of the bridge, a traffic bearing grated drop inlet with double frame and grates (2GI) was placed on the right side of the roadway in the shoulder berm gutter to pick up runoff from the bridge. Class -II rip rap abutment protection on both banks of the stream is also proposed to prevent future erosion and stream migration. Deck drains will be required to meet spread criteria but the drains will not discharge directly above water. Impervious dikes will be used around existing abutments to prevent the sediment from entering the stream during the removal of existing bridge and will be dewatered as needed. Waterbody Information Surface Water Body (1): Rocky Creek NCDWR Stream Index No.: 12-108-11 NCDWR Surface Water Classification for Water Body Primary Classification: Class C Supplemental Classification: None Other Stream Classification: None Impairments: None Aquatic T&E Species? No Comments: NRTR Stream ID: Buffer Rules in Effect: N/A Project Includes Bridge Spanning Water Body? IYes I Deck Drains Discharge Over Buffer? I N/A Dissipator Pads Provided in Buffer? I N/A Deck Drains Discharge Over Water Body? INo (If yes, provide justification in the General Project Narrative) (If yes, describe in the General Project Narrative; if no, justify in the General Project Narrative) (If yes, provide justification in the General Project Narrative) I 0 See Sheet to For Index of Sheets See Sheet 1B For Standard Symbology Sheet m i VICINITY MAP BEGIN TIP —L— STA.11 + 50.00 To 1, ap NIX ITHIS PROJECT IS NOT WITHIN ANY MUNICIPAL BOUNDARIES. CLEARING ON THIS PROJECT SHALL BE PERFORMED TO THE LIMITS ESTABLISHED BY METHOD GRAPHIC SCALES 50 25 0 50 100 PLANS 50 25 0 50 100 PROFILE (HORIZONTAL) 10 5 0 10 20 PROFILE (VERTICAL) DESIGN DATA ADT 2016 = 560 ADT 2040 = 1120 DHV = N/A D = N/A T = N /A V = 35 MPH FUNC. CLASSIFICATION: LOCAL SUB —REGIONAL TIER STATE OF NORTIH CAROLINA DIVISION OF HIGHWAYS IREDELL COUNTY LOCATION: BRIDGE #166 OVER ROCKY CREEK ON SR 1595 (COOLBROOK RD) SURFACE WATER IMPACTS PERMIT —JS— i BEGIN BRIDGE l -L- STA.15+05.06n END CONSTRUCTION DR1— STA.11 +15.00 PROJECT LENGTH LENGTH OF ROADWAY TIP PROJECT BR-0115 = 0.107 MILES LENGTH OF STRUCTURE TIP PROJECT BR-0115 = 0.026 MILES TOTAL LENGTH OF TIP PROJECT BR-0115 = 0.133 MILES NCDOT CONTACT: DAVID STUTTS, PE Structures Management Unit END BRIDGE -L- STA. 16+42.94 OTIL 'AT8 STATE PROARCT RRPRRRNCR N0. SN,EDET SHEET NESTS ,c, BR-0115 5 STAIR PROS.— I DESCRIPTION 67115.1.1 1 2020001 1 P.E. NqD a 3 Nq`77 — TO FOX MOUNTAIN RD END TIP PROJECT BR-0115 —L— STA.18 + 50.00 PLANS PREPARED FOR THE NCDOT BY: Srr V 100 STV Engineers, Inc. 11 V/ 900 West Trade St, Suite 715 202 �j Charlotte, NC be, NC License Number F-0991 2018 STANDARD SPECIFICATIONS SHANE SHARPE, PE RIGHT OF WAY DATE: November 27, 2019 PROJECT ENGINEER BHUPESH R. JOSHI, EIT LETTING DATE: APRIL 21, 2020 PROJECT DESIGNER . +1iA.�ii�>r�'+;��� Permit Drawing Sheet t of s INCOMPLETE PLANS DO NOT USE FOR R/W ACOUNITION DOCUMENT NOT CONSIDERED FINAL UNLESS ALL SIGNATURES COMPLETED HYDRAULICS ENGINEER OF IIOBiy a�4� °490 e d P.E. z + h' SIGNATURE: ROADWAYDESIGN ��~T ENGINEER °F TewMge�e4� P.E. SIGNATURE: LL _— / /� / / /// / titi // l 0 /�/ 5/ // // //// // // / / / PROJECT REFERENCE NO. SHEET NO. so' / / // ti / o ///// /%// �i/ // /i/_� / / / 0g0- / q STV Engineers, Inc. /// / / / /// / / / STU 1009 00 West Trade 28202 0 Suite 715 ////�/// NC LcenseNNumbe 2F-0991 BRKW /SHEET NO. 4 ROADWAY DESIGN HYDRAULICS ENGINEER ENGINEER OLOT \ttae— / ;� / m/ m% >�s�///� /i / DOCUMENT NOT CONSIDERED FINAL �`� l0^0� / UNLESS ALL SIGNATURES COMPLETED 1 /// ////////// / �� SITE 1 'SITE 1 �// // ///////// ///�' %/ �/ �/ BANK STABALIZATION & / / i BOTH TEMP. WORKPADS ARE NOT TO BE CONSTRUCTED AT THE SAME TIME. �_/ IMPACTS IN SURFACE WATER / //V ///�////` � ��/r �j �i � E LFP WORKPAD ACRES" NOT BLOCK OVER 50% OF THE STREAM AT ANY TIME. 04 LF. /0.01 ACRES/// _ / / /// / / RIPRAP AT �BANKME�T_ /////// i / /�/i / ��+ s2- TO —rb + O6 LT _-DETAIL j B', DECK DRAAN—RIMWC,PAD = - ; ; =WWRAP TYP. �� 1 SF�ECIA� CATER) 11 DITCH / f — / P / i 16 +6 TQ fii+ 50 LT �1 PUE r �DETkA /i7 �,, // \w oq� v — I o V j 0 � 40 — j C j/ \ \ wows AT — �� �� RCP � l �� �. / �i9' BST B 2G1 \ E ISTING' —. PEWRON w � n� _ - _ p=AP��gfl� P��'���\\ \ CAVA \\\\gym \ \ \ :�\� ��\\�� \ `��A 1— 7 ,8A � IR OSLEY— — N \ A/NSV(fiXPJ x4'SL-0 \ — SITE 1 \ \ \\�\ % (fT� 1 \\ \ IMPERVIOUS DIKES TEMP. IMPACTS IN SURFACE WATER \ \ \ 11 LF / < 0 Ol ACRES r LEGEND DENOTES TEMPORARY IMPACTS IN SURFACE WATER s DENOTES PERMANENT IMPACTS IN SURFACE WATER STREAM PERMIT IMPACT AREA (AC) LENGTH (FT) TEMPORARY 0.04 11 SW IMPACTS PERMANENT 0.01 104 SW IMPACTS BAN TON—_--- / V 77 V A 25' 0' 25' GRAPHIC SCALE \\\\\ s 6e — Permit DrwAin \\�\\\\\\\\ Sheet 4 of 5 \ TEMP. IMPACTS LENGTH TOTAL = 115' \ SITE 1 (104 COVERED UNDER PERMANENT IMPACTS) *CAUSEWAY TEMP. IMPACTS LENGTH = 84' _ —ab\\ \ \ \ \ \\\\\\\\\\\\\\\\ �\\\\\\\\\\\\\\\\\\\\ \\\\\\ � \ \ COVERED UNDER 104' OF PERMANENT IMPACTS WETLAND PERMIT IMPACT SUMMARY WETLAND IMPACTS SURFACE WATER IMPACTS Site No. Station (From/To) Structure Size / Type Permanent Fill In Wetlands (ac) Temp. Fill In Wetlands (ac) Excavation in Wetlands (ac) Mechanized Clearing in Wetlands (ac) Hand Clearing in Wetlands (ac) Permanent SW impacts (ac) Temp. SW impacts (ac) Existing Channel Impacts Permanent (ft) Existing Channel Impacts Temp. (ft) Natural Stream Design (ft) 1 -L- 15+23 TO 16+16 STREAMBANK STABALIZATION & IMPACTS IN SURFACE WATER ON BOTH LT AND RT SIDE OF THE STREAM 0.01 104 1 -L- 15+11 TO 15+83 -L- 15+69 TO 16+29 IMPERVIOUS DIKES & IMPACTS IN SURFACE WATER ON BOTH THE LT AND RT SIDE OF THE STREAM <0.01 11* 1 -L- 15+27 TO 16+08 TEMPORARY WORK PAD/CAUSEWAY ON BOTH LT AND RT SIDE OF THE STREAM & IMPACTS IN THE STREAM 0.03 0** TOTALS: 0.01 0.04 104 11 *TEMPORARY IMPACTS LENGTH TOTAL = 115' (104' COVERED UNDER PERMANENT STREAMBANK STABILIZATION IMPACTS) **CAUSEWAY TEMPORARY IMPACTS LENGTH = 84' (COVERED UNDER PERMANENT STREAMBANK STABILIZATION IMPACTS) Revised 3/31/05