Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SW4191001_17-002 Rev05 2020-02-05_2/6/2020
NAK(;LL IU#J I /U,)Ub, I /U,)UJ, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I / ECE GENERAL NOTES GENERAL NOTES 1. EXISTING BOUNDARY AND TOPOGRAPHIC INFORMATION TAKEN FROM SURVEY DATA SUPPLIED BY R. S. JONES AND ASSOCIATES, INC. 2. WORK WITHIN PUBLIC RIGHT-OF-WAYS SHALL BE IN ACCORDANCE WITH ALL FEDERAL, STATE AND LOCAL REQUIREMENTS, NOTIFICATIONS, STANDARDS AND POLICIES. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR TRAFFIC CONTROL MEASURES FOR ALL WORK W/IN PUBLIC R/W PER THE MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES FOR STREETS AND HIGHWAYS AND THE N.C. SUPPLEMENT TO THE MUTCD AND LOCAL CITY INSPECTORS DIRECTION. 4. ALL CONSTRUCTION SHALL BE PERFORMED IN ACCORDANCE WITH THE PROJECT PLANS AND/OR SPECIFICATIONS, LOCAL STANDARD DETAILS AND CONSTRUCTION STANDARDS, STATE CONSTRUCTION STANDARDS, AND OTHER APPLICABLE CONTRACT DOCUMENTS. 5. CONTRACTOR IS FULLY RESPONSIBLE FOR CONTACTING ALL APPROPRIATE PARTIES AND ASSURING THAT UTILITIES ARE LOCATED PRIOR TO THE COMMENCEMENT OF CONSTRUCTION. CALL NC ONE CALL (PREVIOUSLY ULOCO) AT 1-800-632-4949 FOR UTILITY LOCATING SERVICES 48 HOURS PRIOR TO COMMENCEMENT OF ANY WORK. CONTRACTOR SHALL VERIFY LOCATION AND DEPTH OF ALL EXISTING UTILITIES PRIOR TO CONSTRUCTION. 6. UNDERGROUND UTILITIES SHOWN USING BEST AVAILABLE INFORMATION. ALL LOCATIONS SHALL BE CONSIDERED APPROXIMATE ONLY. THERE MAY BE MORE UNDERGROUND UTILITIES THAN ARE SHOWN HEREON. CONTRACTOR SHALL FIELD LOCATE ALL UTILITIES PRIOR TO ANY EXCAVATIONS. 7. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING UTILITIES TO REMAIN DURING ALL DEMOLITION AND CONSTRUCTION ACTIVITIES. 8. ALL CLEARING, GRUBBING AND UNSUITABLE FILL MATERIAL SHALL BE DISPOSED OF LEGALLY. 9. ALL PAVEMENT, CURB, STORM DRAINAGE PIPE, AND STRUCTURES TO BE REMOVED SHALL BE HAULED OFFSITE AND DISPOSED OF LEGALLY. 10. SIGNAGE SHALL BE LOCATED AS SHOWN. SIGNAGE SHALL BE CONSTRUCTED IN ACCORDANCE WITH LOCAL STANDARDS. 11. SITE LIGHTING SHALL AS SHOWN, AND SHALL BE SUFFICIENT TO PROPERLY ILLUMINATE THE SITE IN ACCORDANCE WITH LOCAL STANDARDS. 12. LANDSCAPING SHALL BE INSTALLED IN THE PROVIDED YARDS, IN ACCORDANCE WITH LOCAL STANDARDS. 13. NO SIGHT OBSTRUCTING OR PARTIALLY OBSTRUCTING WALL, FENCE, FOLIAGE, BERMING, PARKED VEHICLES OR SIGNS BETWEEN THE HEIGHT OF TWENTY-FOUR (24) INCHES AND EIGHT (8) FEET ABOVE THE CURB LINE ELEVATION, OR NEAREST TRAVELED WAY IF NO CURBING EXISTS, SHALL BE PLACED WITHIN A SIGHT TRIANGLE OF A PUBLIC STREET, PRIVATE STREET OR DRIVEWAY CONTAINED ON THE PROPERTY OR ON AN ADJOINING PROPERTY. CONTRACTOR SHALL NOT MAKE ANY MODIFICATIONS TO THE APPROVED DRAWINGS WITHOUT PRIOR APPROVAL OF BOTH THE DESIGN ENGINEER AND LOCAL INSPECTOR. GRADING & STORM DRAINAGE NOTES: 1. ALL CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LOCAL CONSTRUCTION STANDARDS, SPECIFICATIONS, AND PROCEDURES AND THE NCDENR'S SEDIMENTATION AND EROSION CONTROL STANDARDS, SPECS., AND PROCEDURES. 2. CONTRACTOR SHALL VERIFY THAT ALL APPLICABLE STATE AND LOCAL PERMITS REQUIRED FOR THE COMMENCEMENT OF GRADING OPERATIONS HAVE BEEN OBTAINED PRIOR TO START OF GRADING. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR FIELD VERIFICATION OF ALL EXISTING UTILITIES PRIOR TO THE BEGINNING OF DEMOLITION AND/OR CONSTRUCTION. 4. CONTRACTOR SHALL BE RESPONSIBLE FOR PROTECTING ALL EXISTING UTILITIES TO REMAIN DURING ALL CONSTRUCTION ACTIVITIES. 5. ALL STORMWATER MANAGEMENT FACILITIES SHALL BE DESIGNED AND CONSTRUCTED TO MEET ALL STATE AND LOCAL REQUIREMENTS, INCLUDING THE STATE STANDARDS FOR WATER QUALITY AND DETENTION FACILITIES (CURRENT EDITION). 6. EROSION CONTROL IS PERFORMANCE BASED. EROSION CONTROL MEASURES SHALL BE PROVIDED PER THE EROSION CONTROL PLAN AND AS NEEDED TO PROTECT ADJACENT PROPERTIES. 7. CONTRACTOR SHALL PROVIDE ALL STAKING, FLAGGING AND/OR FENCING NECESSARY TO PROVIDE PROPER PROTECTION OF THE STREAM BUFFER. BRANDYWINE DR �o F 4 � O,Q QOi SITE �c ,y wy sg VICINITY MAP i"=2,000' PRELIMINARY SUBDIVISION PLAN FOR. 1_ N ID N 1,R- IIA-il IIA-il U 13 ID I,- V IS.- IS.- 0 N PROPERTY LINE EASEMENT SETBACK RIGHT-OF-WAY CENTERLINES CURB & GUTTER EDGE OF PAVEMENT SIDEWALK CREEK STRUCTURE NO. CATCH BASIN YARD INLET STORM DRAINAGE JUNCTION BOX CURB INLET SANITARY SEWER MANHOLE SANITARY SEWER CLEANOUT METER BOX VALVE FIRE HYDRANT FIRE DEPARTMENT CONNECTION LIGHT POLE UTILITY POLE AND GUY WIRE CABLE TV LINE ELECTRIC FIBER OPTIC CABLE GAS LINE OVERHEAD UTILITY LINE SANITARY SEWER STORM DRAIN PIPE TELEPHONE WATER LINE GRADE CONTOUR FINISHED GRADE SPOT ELEVATION CLEARING LIMIT/TREE LINE LIMITS OF DISTURBANCE DITCH OR SWALE FLOWLINE TREE PROTECTION FENCE SILT FENCE FENCE RIP RAP APRON CHECK DAM OR COIR WATTLE SEDIMENT FENCE OUTLET INLET PROTECTION ELECTRICAL TRANSFORMER LEGEND NEW E FO G- OH SD T w 400 356.44 SF SF SF Fol EXISTING XFO XG XOH xss XSD XT xw x 356.44 EIP EXISTING IRON PIPE 0 EIR EXISTING IRON ROD IPS IRON PIPE SET PKS PK NAIL SET X ❑T CP COMPUTED POINT 0 It �1: I "Iffill) 1111� "I - I'll 4i )� " ( 1192 INUM RMNIVER HL 1111 000 0\ 1s) RUN& LE CAM PROJECT INFORMATION: OWNER/DEVELOPER: ROBERT M. BRAME 2863 SOUTH JIM MINOR RD MEBANE, NC 27302 PROPERTIES INCLUDED IN PROJECT: 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD PIN# 9802-59-3969 PIN# 9802-59-3974 PARCEL ID# 170308 PARCEL ID# 170309 TAX ID# 9-13-183 TAX ID# 9-13-184 2.8 ACRES 3.3 ACRES 2863 JIM MINOR ROAD 2817 JIM MINOR ROAD PIN# 9802-59-5721 PIN# 9802-59-4690 PARCEL ID# 170310 PARCEL ID# 159117 TAX ID# 9-13-185 TAX ID# 9-13-5 1.68 ACRES 14.25 ACRES CULBERSON LN S JIM MINOR ROAD PIN# 9802-58-4657 PIN# 9802-58-9583 PARCEL ID# 159114 PARCEL ID# 159116 TAX ID# 9-13-4A TAX ID# 9-13-4 6.01 ACRES 13.71 ACRES TOWNSHIP 9: THOMPSON DEED/PLAT REFERENCES: DB: 2823 PG: 0093 PB: 073 PG: 0293 DB: 3239 PG: 0957 DB: 2487 PG: 215 PB: 073 PG: 0293 SOILS: CnB2, CnC2, CnD2, CnE2 = CULLEN CLAY LOAM = GROUP C RvA = RIVERVIEW LOAM = HYDROLOGIC GROUP B WtB = WYNOTT-ENON COMPLEX = HYDROLOGIC GROUP C FEMA MAP #3710980200 K, EFFECTIVE 11/17/2017 FLOOD HAZARDS PRESENT TOTAL ACREAGE: 41.74 ACRES BY SURVEY TOTAL # PROPOSED LOTS: 33 LOTS AVERAGE LOT SIZE: 0.49 ACRES (NOT INCLUDING LOT #33) TOTAL OPEN SPACE: 530,223 SF OR 12.17 ACRES WINDING CREEK TRAIL: 316.09 LF FOREST CREEK LANE: 1,186.86 LF PATTON MILL LANE (PRIVATE): 1,271.77 LF 17-002 Project Name (10/17/2019) Existing Proposed Gross Land Area (GLA): 1,818,140 1,818,140 Project Area: (GLA-surface water) 1,599,584 1,599,584 Impervious Area (site) Roof 992 0 Roadway 0 50,518 Parking / Driveway 9,212 2,581 Sidewalk 0 180 Impervious Area (lots 1-32j Roof each lot = 2,000 Driveway each lot = 1,000 Sidewalk, patio & hardscape each lot = 500 Lot allowance each lot = 1,000 Impervious per lot each lot = 4,500 Total impervious for all lots 32 lots = 144,000 Impervious Area (lot 33) Driveway 16,092 Future Roadway 20,000 Future Development 60,408 Total Lot 33 Build Out 96,500 Pervious Area Landscaping/ Other Pervious 1,589,380 1,305,805 Surface Water 218,556 218,556 Protected Forest 0 0 Other Areas Custom Land Cover 0 0 Land Taken Up by SCM 0 0 Total All Areas: 1,818,140 1,818,140 Total Impervious Area: 10,204 293,779 Total Impervious % of GLA 0.56% 16.16% Total Impervious % of Project Area 0.64% 18.37% n\A/NlFD- ROBERT M. BRAME 2863 SOUTH JIM MINOR ROAD MEBANE, NC 27302 PHONE: 919-260-7906 BOB@HOLOQUEST.ORG ENGINEER: CHARLES P. KOCH P.E. EARTHCENTRIC ENGINEERING, INC. 204 WEST CLAY STREET MEBANE, NC 27302 PHONE: (919) 563-9041 FAX: (919) 304-3234 P H I L. K OCH @EAR TH CEN TR I C. COM SURVEYOR: ROBERTS. JONES (L-3939) R.S. JONES & ASSOCIATES, INC. (C- 2565) 201 WEST CLAY STREET MEBANE, NC 27302 PHONE: 919-563-3623 FAX: 919-563-0086 B OB B YJ@R SJON ESAN D ASSOCI ATES. COM INDEX OF DRAWINGS: C1.0 COVER SHEET C2.0 EXISTING CONDITIONS & DEMOLITION PLAN C3.0 SITE PLAN (80 SCALE) C3.1 SITE PLAN (60 SCALE) C4.0 EROSION & SEDIMENT CONTROL PLAN: INITIAL C4.1 EROSION & SEDIMENT CONTROL PLAN: FINAL C5.0 GRADING & STORM DRAINAGE PLAN C6.0 UTILITY PLAN (80 SCALE) P1.0 WINDING CREEK PLAN & PROFILE P2.0 FOREST CREEK PLAN & PROFILE P3.0 OFF -SITE WATER PLAN & PROFILE D1.0 NCG01 GROUND STABILIZATION AND MATERIALS HANDLING D1.1 NCG01 SELF -INSPECTION, RECORDKEEPING AND REPORTING D1.2 EROSION CONTROL DETAILS D1.3 EROSION CONTROL DETAILS D1.4 EROSION CONTROL DETAILS D2.0 UTILITY DETAILS, WATER D3.0 STORM DRAINAGE DETAILS D4.0 SITE AND PAVING DETAILS D4.1 FUTURE TRAIL PARKING DETAILS CALL BEFORE YOU DIG... IT'S THE LAW. CALL N.C. ONE-CALL(1-800-632-4949) FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 APPROVAL STAMP w U L Cz W E 0 U U U T L LU N M CN O U co N ' (u �LnC`7 O YU cz Z T T Cz C Cz .. J N2a-LL.W S I J0 z U w z U z y d J 0- I� � 0 r ; N N W W 0 E-1 w Q W w w w o2C O 2 1.- 2 U O O OU w 0 Z U w U 0 Z U> � O � Lu U w 01: 0 oc 0 O oc oc w wwoCww 0 D_ oc w D_ D_ rn rn rn m 0 w o 0 0 0 0 CV CAI CAI N N Q 0\0 C\O CO CO CO 0 � 7 CD O O O O r CV O > w r N CO � LO DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=150' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 WORKING THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. P:\17-002\17-002 Drawings\--Working\17-002 Working.dwg, C1.0 - Cover, 2/6/2020 8:53:04 AM PRELIMINARY SUBDIVISION PLAN F'AN(-LL IU#J I /U,)Ub, I /U,)Uy, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I / u �14 wy sg VICINITY MAP i"=2,000' PROJECT INFORMATION: OWNER/DEVELOPER: ROBERT M. BRAME 2863 SOUTH JIM MINOR RD MEBANE, NC 27302 PROPERTIES INCLUDED IN PROJECT: 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD PIN# 9802-59-3969 PIN# 9802-59-3974 PARCEL ID# 170308 PARCEL ID# 170309 TAX ID# 9-13-183 TAX ID# 9-13-184 2.8 ACRES 3.3 ACRES 2863 JIM MINOR ROAD PIN# 9802-59-5721 PARCEL ID# 170310 TAX ID# 9-13-185 1.68 ACRES CULBERSON LN PIN# 9802-58-4657 PARCEL ID# 159114 TAX ID# 9-13-4A 6.01 ACRES TOWNSHIP 9: THOMPSON DEED/PLAT REFERENCES: DB: 2823 PG: 0093 DB: 3239 PG: 0957 DB: 2487 PG: 215 BRANDYWINE DR \VA \ \ �� / // /��` �__ A VAV�\\ V V\ \VA \ / _ / (� _ / 1 / / A i ��ii7 _— �/� � /i// // V v � - � OS \ �- ///// / \\ \ \ \ \ \ / p _� i /i/ -- - // / \ \ \ �� l«oz) se ava-arar� �nr ) V A V - / / �/ /� - \VA V� VA ���\ \ �v \ = - - / / / v - � I / + . 5p + - /- _ _ ��%-5�5 _= __ -� �i//i / - _� — �� l/ T 1 / / \ V A \ A / - v �iii/� - - - / _ \ \ / ///�..�/� // / -� \\\ VA \�� A� \ VA�OS�. / - / _ - �500= i�i�� — _5��j== �y� / / A - I I A _ A // // / / / _ A A V A A \ \ \ �0 \ V� / - ��_� __ ���ii '� / /�J / / \ �� // /// / /// s VVA A V A\\ \ �/ / --- �� - _ —i- 4ti � V \ \ V I I I I \ v / - / // / // / / �v vVvozVAV A \\\ \V\ �� ///=���o =/i/ _ - - - - - V \ \ I I I I ) A ----- / i�// // / / - -vvv vv��vvv /\\VV A / / �� +'� // / i'i///=55 i' --- _52- - _ - �/ //- / / / I - - sos_ / / /// ////// / / - ' - � vv\ VA A VA \� A \ \ �/ / �o� - + \ �\ \ )+ I I � / / / //� //// / / --520- r V A \I I I I I � \ V - _ - — - � /i /////�/� i / / vv\ v VA �\ \ \ \ � / / //i �� \� /� / — - / / /// /�v�v v \ V AVA\\ \ \ // o \ �� // /� / / \ V A \ II 1 \ \ v / // / / // / --_ ' vvv\\\VA \\ \\ \V\ v �°o C_ � / \�\ �� _ - / / --_ \V A \ V \AA\ v //� — �� V /////�//�///�/ - v£s. AVAV\Vv v s /// I A\\ +II ////' / v /-v v// //- _ \ I \ \\ \ --- A \ / / // ///// / / / _ --_ AVA\ \\VA \\ \\ \\\ \vv v / - / / / � / _--- / // r � \ + +\ ���II \ - // /- \ \ \ \ ols- / / _ / \ \ \ V v s v - �/ /i/ - / ( ) � o I I / - _ V A \ A / // // / / / / \ \ \ \\ \ \ \V \ vv v ��o� v \ / // - / / i� _ �5� 5 - v v \ \ V A 1 \\ \ \ \ - ) / / / // / v V� \ \ \ - - // /-----� \ V \ \suet/ A \A \ v--/ �� _ /� // / / / / \ V� �! v s / / / 1 \ o; �I �I �I ��� / / / / V A \ s., V A V A \\ \ / // - A Tv // // /)//// / / / (/ /-v VA V \ \ \ \ \\V��A� \�A`\V /� j� �j / / //+// / i�\\1v'�� / � -_ _ / / / _ VA V A \ I \ \ �A VVA \ ) \ VA �� // -sls \ \ l __ � �� /// / I / V \ V� \ \A/ \\ �\ �- _--- // / / /�/ / / �iI \ - - // / - --= \ \ 1 vvv-/ /--- v ( _v v \ V Avvv vvv v vv vv v� -_ / �•�/ )/ / // III � / // / / - / t \ \ \ \ A \\ �I \ s�vv vv v�--- _- __ / s\ \\V �I w� - -- / --- \\\\s\ \ \\s \ -_- / / 1 AA \ I I I \ \ \ \ V /�/// �V -'� ` v In I A \ V� / / /� - AV� \\ \ \I -d A // / / --- � - ol 1 V \ 11 /// /- V�\ n v I I I o A A v vvvvvvv v v��- �� //��/ / V11 I/ // / / V*� �\\VAA VA\ w�N�r� / // // --__ // // / oas \ v / 1 M I \ ) v v v v vv _- - - / / V /+ + +VA \\ \ �\ \V\ rn rn / / // / / / / — ors / / - - eon I 1 1 / � v/� 11I I � \ s� v vvv\vvvv v\��- --- / / \VA \II( ti / V�. AVA\\VAA VA\Y����� / ��,- // / I I I I I I ) I I I / \ ///i /v A --v )V \ s v w v vvvv vvv 4s - // / /i �I� + + \ A\\ \ \\\�� c� o o � � / / / � - w / / / \ 1 I I ( /// vv \� \I I ' vv v v� �_; / / II �� � V' VA\\VA\ sv�Q 1 u-- /I / // v /( -% \ I I I I -- -Z / 11 1 �v v v� v - v / - / o �, v �� �Q-- -�/ / /�///// _ / �� // \ \ � / v v \ \ A v v _ _ - _ 1 � svv Co 0 d �- / / � / / 5c \ V 1 \ M / / / / \ / s v v v v v �+ +\ \ \V �s V A I �, A - / // / \ )11 � I I A £s�� vv vvv �v 20 I I I I I IIII oo' I "�\ \ \ \ ' \ �w\�� �� m m �— _ = �i i //� / _ _ _ v / /� A \ \ V A\ U //i =/ // / �/ \ \ / I I cam\ / �/ -- V / \ - %� / I I I I I I I / \ \\\�S ` \ \ V \ \ % I I I I �' �-••. A\ A � Q �- - --- / -�_ - I \ \ / / // ) - - - syvvv QRQ - ��� - / - \ l \ v / - v v 1 / l v v v\ v �-/ /// 1 �+ _ v z - - - I \ I // / / / I / / - -� s / / // v vv vvv/ vvvv -- �_ I I I \ V � � - =5�a �// - �`v s0 -- / l / 1 I / / l -� / // / / \ / V A \� V I / / / Sao- v v vv vvvv vvv v\ - v / r + _ A + v v _ /III / / / / / / A / / �vvv� vv \ )( liI � I I / o vvv __- __ %/� -- v �I/// / / / v- /// �// v 1 I�I _ 11 \ \ \v vv vvvv\v�vv`� �I �I I I o + +.off+\ V I �+s� \ _ _=--5o�--kvA+v _ // / I I / / // I 1 I iI >II'I / �) v v\ vv Avvvv v IIII 1I + / / / I ) / v /'_ / / I - / � � 1 I I I I I 1 \ V A \ \ /v v v\ v - A ( �\ I V A + v__ _ = _� _-- v s / / / / / / / - - \� \ \ - A \ \ \ V A \ � \ \>. I .z 49 S64 \ i // l i/l//�,I / 11I �� v v // �v l�, �' --y v— vI l vv v v �v vv vI v v yv vv v o w0)v y . A + + , /> - �+ — � + v � / s v / / / / I 5 /- v A V A v A v V A\ \�� vv vv \ zCn (( \�,� A v / \ v v � / V A�( / / / / - v v v _ v _v� A \ \ / /a/ 1 // /�(I A / / - A / ��//_ v vv VA\\ �A vvv A \ v �A \ VAA \ "��` \\ aovA\ �+ + " +\A -N +*'�+ iv \ / /�' / \ / / � _ v-- 5 v \�� \� >-s,AA�V1 /� Vi s v \\ \ aco��N�vv v _�w�V Av-. _ \ // // \ A / / \\ \ V \ \ \ \ £ V� �� N \A O \�� V / \ / / - A U V Q + + L � + + +• + + + + + �- / - \ V A U) I \ \ mA �A / / \ I I I �/ / /� - \ _ / -- - / / % 1 \ 1 A \ A \.5� \ \ \ �_ V �C)C V A,, W VA �- - �COO� u) ') _+ % I \ M h / / - A - / / V A AI \ �) IA\ �A�� v� �v Vv - Leo ow /� + + + V A i �+ +I + + +/ + + / / ) / / \ v -- ///�/i ` v _� �\ \ / / \ 1 v v\ �Qo vvv zsv v_=_�°° CO�zo`ys Qv ��� v V i % / / l � \ \ / / / / / /=i / v \ i J / A V I I vv\v viz - v�\- �s= N a� ��\vss l ) l \ \ \ l / / \ \ \ \ J // /i / l -530 \ \ // i / ( \ I I I I �) \ �_ s\` \` \o m J I f Q ap w _ ��� \�\ - - z ,�� �500 �1I +.. o + + + / + // / / vv z - I � I � . ) / i b \ vA �- - H o \ V✓_- / \ / V J - 1 I / W / _A o -` �£ � - b W VA / \ / 0� / //j //� ///� / --- /v V A /�� \ - / �� vv v- _����� \vv -�n �o � �. 1� / / // 1 / / �� / i / i V i / / i v �z�ao s sJl ��O Z� �w 3Q- /// f / �� \ 00 00 \ -� N\ W \\ - s ) / I / / % \ \ _ - -/ \ \ _ / - \ \ _ ,� o� o _ f \ - \ \\\\\\\— o m=s1 , ��s \ + + fi/ �500 + / / / / / d /// i /-��- �\ \ \ o / - -/�- \_ A� /\ v� -� I rnr7 r7�_� �� �A v� o co / / l M / // �� \ / i / - - - AVA \ h7) / 5i \ N _ \_ / v VA N \�\ VA\V�� \ V� / /� / /�rD �/ v ao - aoVA� w� +� / / / /+ // / / II / / �/ - �v - --/A\s V� 5� /�v -� \ - /r�o� �_ _,�,aco�o N ,y _ 1 �- �� �v vsss l w / / /- / / I / \ r� - \\\\ \\\�\ I ) \ � <' l l e /� / � I I l / I 11 J / / / ' - - \\�S� i - / I/ I I W ' / \ - ,(n N �ko = = _ \\ \ \`� ( I � I U\ / // // / / + \ + // / / / / / �/ / �� %�_ 1 c - _ / / / / / i )/ l l / l / lI l ) �/ // / /�/ V s5� % - - _ v � v - _ 1 � / / - _ l W o �o �o sv-� o �� �� eM3 -_ w / /// / �/ / / / / / / /// l I _� / / // / -V V / //��=i -- �\ \�� _ - /�/ / -- �\ � O U �� A S\ S \, � V \ / / o / 5 \\ / / / - / // % \ ���w�_jcoco-_ wA vA A\\ VA V=£swv �3i1y�0 V�\- � \ �� 31 / + +/ / / / / / / I // / / / ///o - - - A /� \ I v Q_ . / /� / / // / / / / / / // / A / / / � A - � a/ \ VA\V -� - � - _ - �� �// �"'- / z z � m o o _ jV A\ \\\ V A \ \\\s uev �w� � 1 1 I / / /� / / / / / / / / l / /� / / _ — v /i//� /I v _vvv vv — _ � //i� /' / v o / / v� z m — — _ —�� vvv vvv �v 0 \ \ V \ w \ �s �� / (I I I I + / / v \ II +. + + / / l / /// / // � / I /////�- / v - // - -sbs v \ _ /i/��� r v 0 �-v� vvvvvv vvv AVA\ \\ N V v ����� I � l III II vt 1� �i� IIII II+� + + � // / / I - / / / // p/ % / ( \ / / // // // - -- \ \ �� / / ` VA\\�SAA -'- - 540 - ///� _\ \ AI V A �S'\ \ \ \ V\\ A V A VA \� . - \ / /� // /i / / t / /�/ // � --ob � / / I / - - \ \\\ v� _ _ / � � \_ � v �o \ / � ti V As \ V \\ \ V�A \ \ v� V v �\ /1 1 \\VI �(+ \\ \ !� IIII + // / // / / I/ / / / / ( i ////� �/ // \VA\ --- _ /// _ / - VA-� zN� A V\ \\\ \\\\ VV A\ VA �/� /// / / / \ /i/// / - \ / \ \ \ _—sbs�=_ ��� h \ \ \ \ \ \\\\\\\ \\\\\ II �I I \_ I I- I\ 11 I \ o /// // / / / / ' / / / / / // /J /— = .___ /�/_ / // \ \—\mN��,\ /��� \ \ \ III \\\ o / / / - / / / \ ✓ / _ v - - - - y�� /i / �� - /- v v 00 rn v � h \ \ \ \ \,\ \ \ \ V I I I ���� 't o + 1 sv+ // / // / / I \ \ / \ _ �535' - / // / /--v � // / / / / / - - _-- `�/ / / / —_-vLLco� v v /L V A \ V A V\V I I //A w \ VA // / / / \ // // v v \ i / / � ` / / /i/ /� /- N� yvbv \ \V A\\ \\\�\VA A\\V�1 11 I I I II( /) /jJ / �� /+/ / III( 1+1 A� v� / �j / \ "' 1 I I v - / / - - / / / / / -� m a`'v --- Sao "�\\�sv- A A V� \ / /�/ A \ VA _,// // / \ v --- / / / // v v A / - / v ��50 - vvvv \ \ s \\V A \ / / / / / W Cr W \V �� - �A �- A \\\�\\\ \ I I / / / \\A \I - / / � \ V / I / / / O b v v \ \ V A\\\ Q A\\ / �/ /+/ / rn / /// / / - - - - _ 540-� / /� - v / r / � \ / v \ lam _ , :*lz v s� � v v - A \) V � \ \ \ \\\ �\ I (/ / / /�� /+ 4-I 0 � \+v / / / / \ // �/ � l �i - ") \ �/ __ —' .�za .vv vv _`- '-- / V\ vv r \ \ /o A )VI ( �( / / //// / / \ - - - - - - _ - - / �_ - / - / J . / \ \ \ 0- 0- v -_ v\ - _\_ REMOVE ABANDON � \ � \ \\ \ AAA \\\ \ \ \ I ( / / / \ \ \ // / / / / / � � r / A A� - _/j / \ �sA \ / / / / / /_✓� % �/ � V A V A e / , z v �- w �� _ =EXISTING/DRIVEWAY \�1 \ \ \\V �� �\ \VA V A� IIII I ( /�/�/ / / _o� /� Z + \ j / /� / / // A ) vvv----- s _ - �- v s -- _ / ) � / / v v \ v C < > �� �v `v � / �I� I1V� \` \ \ V� I (il// + + / 10 // > ri (� \ --= \ \ \ / // / sss a, / \ \ \ oss \ \ \ \ \\\ \ \ _� a- -\ // of \\\� \ 1\\\\� \\\\III l I I / / // /� / l/i/ /ii _-------vV�,--- '� v v // // / z \ w� / �/' v v v v A \\ \ w v v A - / / \ \ \\v III \ \ -�v� v v A / ��\.> / � v \ - �� vvv /� \ �I l\� II�\VA / / ///� %�/ / _ 7 \ / // / / i�------ vvv v v / � ///-vvv v� v \ \ v v vvv��-s� �- /�/ V A II Q\\ \I I V //+ / // / / / A- -550 �� \ / / / j V A \ \\ \ \ / / - - \V �` - - - ` Sb / / \ \ o' I AV / / / / ///� / -v V V A V / / / -� % - v 1 - ---- V �I I / I / / �� / v, v _ _ / \ v v v\ - - / \ I I 1 / Ij 11111 (+ / /�/ // / / / = = — —sss vvv �-� / - / / V A VA \ 11 I / / -v v v � 1,- \\\ I I I I I III � / / �� / _ - N / // /I/ / --_ - -- ~ \ \ \ \\ \ \\\\ / / / `� sss, \ \ / / (�(/ /%-\ \ \\ - / \ �I /, �� vy vs -� - / ) 11� �I I ) J I II /�" // �// // --- -- A A \ -` v� �v A / / 50 - - /w v � A I I I / /^ A " // - -_ v - v v v / / / / �� v \ V A /��� / ) / vvvv v£s - °vs, _ _ �/ / / / STREAM 1h(////// /"/ I I ) \ V / l N1 I v �� v v , / A- // v�� ��� r7------_- BUFFER ///% // I I I \ \/I I �)V)' \ \ / / v v \ \V1 VA / \\III \�Vv�- _/ / ) / / v v A 1 A / \ \ , / / ' � / a --- V < / _ A 1 I I V I\ i- \ \ ,,------_ / l / / /O i i I \ V A V� / �� I \ / I I \ V A - Of Of N N)� — — — — — — — / / //) / / i / / / / \/ � / �I V I I \ // /)I / �/ I / I I - \ / . \V / v MAINTAIN EXISTING I - - / /� o/ /// �% \ \ / / / / / J I I \ - _ vA v v v V A A / ' / _ MOBILE HOME AND I \ o v \ \ v 0° a°'o - s35- / / / //��/�j/ // /i a v A\ \ \ / 1 \ o\\ / a \ s W u4 I --_ - - -/� //// / / / � � I / - v v v v A - - / m �' A ENTRANCE DURING \ \ \ Q / v V - _ - m eo o - - - _ - / / //// �/ /// /� V A V / +) \ \ / A A \� b I P / v �v - _ gJI�N�� / ///// �// / / /� / - / / // - —sss v ` \ o w \ w ROADWAY \ v o �- _ _ - _ - // /// /� / o// /���!/ / , �/ //� / vvV\ v A A V ss / . A A z / m� s CONSTRUCTION V A \ I /// / �-w_ szs� ��UNrn - -- - //---�)v/,�Az / j //j _•� \ ) / // / / --� `v v\\ v \ V A �� V v 1 �'�� -�,Oo /\\s )A \ I ) l l // , � �� = --Wom i<-; - -_- -pis-�_� �-'>>)/)l%/ice/ //// // , �__/ \ / ) /o-/// / - \ \ 9s \ \ \ \ \ l I / _ �� - - - / /i�/ /�/ /// / / / /// / / - - b / / �` / _ $ �� z \ \ / / a /i/ - \� \ \ V \ \ \ \ \ - / /� / v A \ \ a �V A \III I I I I // REMOVE/ABANDON -o w o - /� /� // , / // - / A v / / - v A \ V A V A ) �I EXISTING PATH _ _hoc oc - - — - - - //� / // � v A - / / / / � _ / i/ \ \ - / \ \ m \ of ^ - - \ - /i �%/// / / -- / ` / '/ / - v vA \\\\� \��, A A v_ -�� ss \ \0- of \ �I �I I - / /1vN f/ / / / / __ vvv s v .- -_; ., v v � v v W IIVII �� =___ _ ---- //„� % // _- \ \ \ \ V A \ \ \ V \ z / h \ \ \ _ ` - - -_- / �O / / / / / - / //o / /// \ v \ v, l \ \ \ V \ - - ` _ �s1 - �5// / o / / //ice - - � - / o \ \ \ V A \ \ � i - A V \ V \\ \ s VA\\ \A�V A \ - vvvv ----� � _ �- / / /• O // ,+ - �_ �- _ ///`o// / ��515= \ V A oc A / - V A V v / V A \\ \ \\\ \� - - - '�%//P��O/, l O•' / / / / /// /'/� _ y V�26b, j�/ /// // / /i - / - - A \ \ \ �� �� Q / / V A \ V V �S� / \ VA \ \\\ VA\�\ \ \ \ / - V A \ I \ m n ( _ v v / \ \ \V A \ V A\\\ VA \ �s v_ vv - �_ i / / i / / / / // / v v / // / / \\C v-� - 5/ 0 / O ��� -_v V�\ / / /o°�/i// / / // �- _ w \ - \ \ \ - / \ \ \\ \ \S \\ \ \ \ \\\�\ \ \ \ - _ _ - �0 /i r o / V A \ \ \ - �� / / `v V A \ / / / A \ V A \ V\V A V A V os \ _-- �o// / o/ /// /�// v�\���� v_ / i�/ ////� / I I I I \ - �- + \ / - \ \\ \ \ o \\ / \ - 1 \ \ \ sss \ HATCHED AREAS \\ \\ \ 1\\ \ \ \\ / /// // c, / // / ///// / \\\\so - / i ////�i/ / / , I I I 1 \ v � e v� I I / stis— v v - v v / \ \ \ VA / / v vvvv �/ / / / / / / _ \ \ / / \ \ \ - / / / INDICATE SUITABLE\ \b\\\\\ 1 \\\\\\ \ \\\\\\\\\�_ - - /�/ j///o, / //// %/ / / //i - \\\\\ / / / / /i /// /// / / - _ vvv _ �/% // / \ \ \ - -� - Q / / // // J // / / // // /// o \ m \ \ \ �, ( / \ solLs FOR sEPTIc \ \\\ \ \ \ \\\ \\ \ \ \\ \ Z' / ///�// / / - \\\\ / / o o v / \ � vim_ - /// _ r v v �i I , � 1 \ \ Q o' A \ I I ) -- v v ssLvv v - +v`+- _ '� �/ / / / +/ /// /// /�� vvvv��s= �// // /ti / //// - as5"- / / / h / // / / / /szo- -sis=-�� /� / � / //// _ _ I / / % .A\ \ / / --- V- -AV\\ / / i ) / I I� I 1 + // / i � / 11 l / - � --�-- �ii///// m 0 / / I / 5 V A VA VA �� 55 / I I /III I I �IIIIIII� � / / // / //// /)/ --- / / / / \p �� _ / / /�o— VA _ - PA v o / / / /I I I IIII I � � / / // //// /h// ,;//// //I / -- — ��_ � ///// �_- - /// / / / / / / �, / rn� / / // /- V - \ \Vvv V- / / �I 11 II I� IIII\ V� �/ / / ////�/ Il(f(ll - --- /=i/� �/ / _ \ / / / / / / / - I I / _ / h / / / / / / - - -_- �525 /i / o, / // v A \ v / V �I�I * / V/ / / / ?5, j // j / \ \ \ /. / _ / �, / / I / v v v - / I- \ V v v TERMINATION POINT OF EXISTING 8" / � -6R R \ / / 555 v v l o I I / //� //( /�// 11 �I I I I I V A � ORANGE-ALAMANCE PUBLIC WATER MAIN (PER \� -S5 / / / \ \ a r� I 1 / P / I I // - / / \ v A� \ - ORANGE-ALAMANCE . FIELD VERIFY PRIOR /. �� . Z�G �1�) ��G/ / / / / / - / / y v v v v \ / / w .� / / R / v v m - ) \ \ ) ( I %/�,o / ,, / // II /I I/ I I I III I / \ \ ��/r,-� / / v A A \� - - TO START OF CONSTRUCTION. \ '( S' `'' 8�- G, / / / v Y a - / oAA \ \ ) /�� //• ��/ / / � / / / 11 I I \ \ / \ v v v a P��� �� - / / / / /A\ vbs vvv v v v v x ) v� I V An V�\ \ \ \I\�o\))� P \ / v � v v v vv vsv v v I � I '� �, v v - /-�/ / �°°�, 60 \ PO / / / i / / / -_ \ �) �A v v v \ oz/ \ \ \ \\ \ V A \ II I OND ) \ vo v _ _-- �� - � �� - -- / \ /�, v v v v v V VA \V A \ \ A\ \\�\ \ \\ �) �� �� \ �n 11�)\ 11I A \ \\ \ V A v �s - - / / / �: �v - o�� ) / / / I / / / - v � o.� v\ /v v v Q / \ V A \ VA vv vv/� v A v \ 1 I j �P ,� w / \ V A A� \ \ v / / 535� /� _ \ - v o' 00 A \ t -� 5 / I I / //// v /vvv v vvvv v \ v A\v vvv vvvsuevvv v\\\\� I ,��./ \ w�,�� �) AI�\lll �)V\\\\ v s�v VA / // /� / / , a �v - X \ / / / 5 - „� _ v v v / v \v vvvv v v vvv �V \ 1 I , / / )) I V A \ \/ v v v A \ / �� / i v \ sb v /// v v ---- / v m �, A v / / � / / / / \ v s \ v v s vvv \II Q / vv v v v - / \� w \ ( )/�/ / _ / / //v v v vv s \v \vv v �vvVA\ \III / / A \ QN // V\ \ I / - - �_ �� ( \ v / , v v v I vvv I v vv vvvv v v v� v v // / /// ) v vv v v W v v v 1 / — — I/—` v v / — v vv o v v vvv vv v �: v w v v - - - - ��X eo � - / \w r7 rn S / - ( \ v v \ \ VA v - / V A \\ \ems VA\ \ vvAVA\ \�A $\III / C ) ? rn v °� / / // / 1 \ V AA \ o \ \\ VA \�\ \ / / / - � v v Q't \� v. ' 8 \ I I l �d£ v \ v v v -v v v \ /\vv \ vv _ -\v vvv A\_ a I (� A > o �I I // / // / / A v v zsv v \� vA \ \� / / / �. / / rn. o \ =a�oo,�� r7v V V A / M /h \ v v V� v \v v A v )\ \ A L Q o/ / v - ��� \ / I V \� v v v - l Il / \ �v vv v \ V A \ \ oc- % �/ o orb I -rn A V A V\ / / i� \ \ �i� \\ _� AVA A\\\ zo AI II i / / A A V A \ / / s v A v �_- vv \\\ \ g0 /�Q^ / / /-- - r -\ m/ ) ��� WO V A ) - / \ l /�/II/�� \VA vAA\ \ \ b - _ ����� \ VAV� �� AAA\�AVAV A �� A - Z U- �� i -� vAv\� AAA \ \ ///-- rn r7 N \ / 5 / / \ \ v \ - v� A I \ �__ A \V (I / V � sss v \ o� / / / \ °p �� �� v \\ssVA ��) / a v _ A - - - oc co 1 �v\\� �\ \VAV� l vO - - - _ - \ I l/� v vA \£ \ / / / / ,�, o Y A s // \ �a � v v v v - A \ v v _ v // �Qiw �E � g� NIW \ / 5 / �� / / // / //// / v v v- --- rn �v VA\/�I. ��� .� / - \V\ \I n o - vvvA \V �S/�� //// /- am � \ �� orn 1 �� \\ A \ / a� / /o// /// A V \vv v � `�0D ��_ \\ vvA\\ \ L=- v V -- \\\ \ I I - w VA �\v -� //�/- - A - 6. cn mr7 W �r7 I V �- A\ / Io I I _ _ - A - /�� of / cP � � cJ d � rn o \ � \ \\ \ - w / / / - o O I ` v VvA\\\� ram-- �! - - _ v vVAA \ < � / / \ / / m / a / // / - V - _ �V A _ AA \� � .. _ .. \ Nn \_VA \VA V / / - - -- W co � ` rn a N oO oc w r` A \ / / h / / / \ _ vvv v vA �- w U) \ - \ V �\ -� - A \\\ \ \ \ _ A / \ �sJ)O ,� W000 -U(nm N \\\ \ \ \ / / / / / / /// /// / // \ __ - s£S gJO)N�. \ -\\ 5z \\ \\\\\\ \ \ / \\\�\ \ _--_///// 00 . vi v> > o �, o N Q 1 \ . Q \ \ \ C �j / / / / / \ - - - \ - m r) o .. \ \\\\ �,\ \) �II \\\\ \ \ \ / ois - \\\ _ - �_ // w cL cA �n m X o \\\ \\ \ \ / 00 \ - / / /////// / \ - - �\\ - _ \� Q N o0 0 \ 540 - \ \\\\ / J IIII II \ \ - - - \\� \ \\ 1\ \ / i _ _ _ _� \\`\ _52? ////, _ /� ,n r�� O. w o d �\�, \� / 0 W� _ �Ur�rn- \ - -�\ )- \\S \ \ \\\\ \ 1 / i--- _ \ \\ \ i//% � % / �M�a0�N�1 �� ��� ��� fir. /��oo H I / Z/ N / \ \ \ \ '"� \ \ \ \ I I. - `� / // //////// %// j5L/MU) 0Lq— V ASS\\, - `- \ \wm0mZX\ \ \ -\\ \\Fs\\� - II\\\\\�\S \ \ S \ \ \ \\ 1\\ \ / % �- —SOS— --=$2 //�j / / �r7 cn� C9 O cLJ�t9 / \ / V A \ S - / / / v\ - - - I\ � A v )\) \ / / _---_�"_ ---= _/> i� /�O� 1 WOrn �� cP pv Q-O �/. A \ v> -/�/// �// //Q��� I- T O �" V ` / AVA \\b\\AA �\ i A V �% - �w / i -� / / o� N rnrn� to A\ �o -% �� // / // �o o rn�r�_ �� AAA\VAv F v �� v 5\STREAM \VA\V� / =J��\\\ 11 /j /�� A���; -_--=i��� / o o �ti 1 lm / \ \ s T -a // / /// // / s� O w o 5 v v vv V \\ / - - // ( �/ w�`� iY _� /y��.•f�o a. / \\ \ rn -/ / / - 1 - \ \\ \ \ \ 5 - `\\ _515_j j z r7 I / m�-rn� -- \ \ \- \ 1 \ BUFFER\\ \\s \\� \ \ \ / \ // / 00 _ �_� — 510- / 1 ) Q ! �O �• 535�m // / / / � I - — - \ __ - � \ \ \\ �£ \ \ \ \ \ v \ \\� \ \ \ / lI / /// _� -� _ 5 // b (� .� ` zrnornw�,� / �� c9� �� / / / / �u \\ ,nc, w_ /////// // / w _ - \ \ \ - \ s \ .^\ \\ _ i ___ _ \ w ao ' . w I� o lij 4r / \ \ ��� 6 r� �� > .d 1 / - / �/ // // / / m N o - -� \\ \\ \ \ \ - - \ \ \ \ \ \ \ \\ \\\ \\\\S \ \ \\ \ \ \\- \ D' / / // // - - - �50ii/ w rn00 / T' // o / / // 0p0p .. \ \ \ - - \\ \ \ \\\ \\\ \ \ \\\\\\ \\\\\\\ \ \ \ // lI I II / , / / ///%/i \_-500-= / L U cn / / Q/ // � / \ \ � � 0• 6' Jill \� \ 00 / / / H Q 0 - _ \\ \ - _ \ \ \ \ \ \ \ \ _ i � - _� - - -= 4s5_ % +�) a "' X Q m� / / / c� / / \ c� s'c� 6�w� v�r: \ //�// ` \ 1 oc U �" o' _ - - �s �'\ \ _ ` \ \ \ \\ \\� \ \ \ \ \) \ 1 /�\ \\ \\ \\ \ \ \ \\\\\ \ \\ / // / / /// / / 490 / - _�-_ - _ _ - v Ymzawz / / / / / / - \ �� o o ds� \\ IN6I., i / /I- \ WOm..X - - -A v \v v vv� -- V < / - - /_ �A \ / - vv \\ �- \\ \ �A A \\ \ \\ \ \ V 11 / / / / / - - - - 490- \ V V \ V ��\ \ // // ////�// // - — _ .•o �o � / m>ozQ \ v �� VA v \\\ \ \\,\\\ \\l\\\\\ \ \ \ v // / // / /----,=-�i �� / V m / / / 6`' / V) W /� / / - / �L��'c�rn0 CL� \\ (�`° /� / �- - A-,-- �� n= \-AvvvA� \ AS ` ` ` VA \ \� �- A V \\\ \ \ \ V A \V III\ // /// \ I / / h / Q ' z/'S /_�/ \� rvd'�.ti�"'� 111 ////� v \ vv s� _ \�\\V A\ \ �VA�\\\ \ \ \\��II \ // ///// _--_ , - - - l _ _ _- yvv v �,��; ; ,� -_ v sv` ; , ` v - - - -_ /// v\ vv vv\vvll v v v\ v I// // / /// / / - ,_ \ ) V A ) a / l / / /�/ / / / � / ) / cL�o�o�,i ll/ _�v v vvvvs! v A v��v vAv` v - _vv\` vvv��-___ / 11 �\ \\ \ \ \ ////// / - �,/ - v m / / - ' �� A _ ` �ozvvvvs \ vv\ v v -_- / 1 \ \ \ I� \ VA \ l �I // // / / - ���) v A W 1 -Q�Q/ ��o �� - vv s \v\ v AL, v_�_v v -\ vv vvv_ // / \\\ �A\\III \\\ \ \ \ \\1 I \�/ /// /// \ A A - \ 575- V / l / ( / - / �/ / O / I I I I / - V A \\ VA \ ! AA V l I VA \ \ //h // // �,/ / / // - A V A \ \ s \ VAS- A V\ \ v v - - A A Vv _ �£S- �- - / / 0 N I I I I \ — O / / v v _ A v _ A A / / �) / . �,�V) / ) I o -- / // `� �/ / / v - - vv v v vv vv / �\ v v v ` ` � - ` `v - / jii v �_/ ////// / / / \ \ \\ �// //j / / // / \ o o) o rn \ \ \ I ( / \ ( ) \ // / / / // l( �, \ \\ \ \ \\ \ \\ \ \ / \\\ \ \ \ \ oZs= - - - --oss_ �/ _ / /// //� /II I I ) \ \\ems\\ . /i//i /i/ / / / / / / /// V A \ �Or7� I A --- ) �� / - // v�-/_- £s. Av v - �____-- __-/ /// /' I III \ \\ /// / ---- // // \ vv A v v o v - v _ - / // A\ / \ -�Of \ y \ \ // / �// l - \ \\ \ \\\ \\ \ �, \\\ - _---_-- - /%ll� I+I \ / �ii// / / / \ \ \ o�Nr-i a \ 0 / Q �I vi / /a / L / - - \ \ \ \ \ v v pwo� L m v VAo / / / \ \ w / m l �� v �vv v vvvv V V A _ vv = �� - =sas -- _ _ ����� / / II IIII 1�11 I\\\ V %ice// // / __�' S,// / _ /_l / \ r� w\ \ / / / cnI'l)0) � // /W � --- � \ \ \\\ \ \\\ �\ \ \ \ \ \ \ _ --- --- / /// /�%I \ \ // / / / / \ \ \ \ \ \ \ N \\ _ \ \ // b I I \ \ / / 4a / \ V �Q N o A vi �n p V A � = oc, �s - v \ \\ \ \ v \\ \ s gTREAM ;�� �� - - 5- % // ) ) / I \ �- - / / / V A 0 � �� A , A LW-i W % / /Lo 4z \ Q � � � � � P71 ) 00 ` _ _ \ ` \ \ B _ �� - - ` �A _ _ � // I I I / / / -£S A \ V S UFrE�� - - �- - �� —520_ 15 / / //� ph) A� \ \£sb� �/ / / / / r j // V \ Q Lq Co — A Q_ _ 0 0) O / / �� Q A 0 H o � 1 W O - - - A \ V \ �- _ _ �� _ - _-_- _ - _ _ - _ _ _ �- - /�/ h \ - �� / / - \ �zmpz ro ) / N� Hr7 / / / I m W Y� . - - �b9 - - V \ \ \ VA / / / / - _ S -__ _-Sl - �= j/% �I 11 l / / � / / / - V / WCo Q� i U rnr7 NV - 0 __ - / / / / W LO / H H / / / In - \ _ - A / _\_ __gyp - - _ _ - - % / / V \ I / /� co v) o / 1 N w - - V� _ _ - - S _ - _ - -/ / h / / _ / / 5�i \ V // / /i / - - \ X A \ / l� -� l V - / / A\\ 0 / / s� \ ��� / /� // QOOr�W�N / �/ / /' - / l I / �mr7Op�W � \ VAA A I )� / )\ ) , I )I / //O' // /� / `�--�----- _- _510�� - /ice/ / �/ / / VA -_ _/ / 4a / -- _ �/ // -- \ \ ) / -- / / // M Y -0-/ / / / �000CA6o W� - - sb \ / % % / / /�/� J..� _ \\s _ _ __� � -�7 0 i - =_- ii �/ / // \\ - - / / -� _ 85/ / 49� - ( - / / p I W� / / / / UN -U(nm S \ \ / / / / / //� // / / ,i�:�..�•{{; - _ - - i i i�i-495 //// \\\�- / - -� �A/ / i \ ) - 5�/ / //��O�LJ r7 / / / / // WO Q \ \ \ \ \\ / / /� // //✓�/ / /// / moo. �I _---'%i'i5iil --__ Yi -/ / � \` \ i/ - - -� //�j/ --- / / / // / 5� _ / // Q�� �W�� r / / >OOZx�Io �� A \ ) ) / // / / / / / /j �/� //// �� in STREAMS - -���� -- i _� __- -- V / / ii - /�� �-/ v _ / _v / � 5_ \ / / // / // /���00� / ) �I \� ) /i // / �,��/ i A oos - % _� /� - -- / / / / am 9$ / / o-���,mw -\\sss\ \ \ I ///////y, // // //� // / / / ( / '. - / __— / / \ \ / - -- \\ //� / J ) I / / / / / / / W�ZQW� \ / \\ M - \ \\ I )// //// / /////%/ \ ji ///) / `�/� _ -_ -\ - //5/ \ ----- _-- \ 4a 4so-=- //; / / / / / / / / /// / 0�m \ _ S�Z \ I \ \ \ \\\1 /// /j/////// /////--// / / // /_ - _-c, � � `\\ - i \ =�ii \\ _ / i� \\\ //////1 -DOC / / U \ \ \ / /ii i _ _� - \- - \ \ \ / / \ b / /- - / ) / I // / / /- _ / / / ( \ ~ ` /� \ ` - - - / j I / // // / .i/ / / - -� = SL _ _ - \ \ /+ + - _ _ = b� \\ \�\+ _/i / / /ice _ _ \ \\ Il / / - / I \ V ) v _ ---_� - s� - A (/ I I V�/\ VI(� //�. /// // (' � - ,_c -= - w � vv 4v ---%�__- ��°as` b - �//o,� _ v AV // / �/ / / \ \ ` \ \ \ `sue � � - - _ \ \ \ \ - _ - - \ \ \ \ \ / / / /tip /// / � / - I '-_- _ = � �00 - - __ = W— — U) N � Nam! \ \\ \ + +/ - - 009- = � _ s\ \\ \ � � / / \\ I / 5 \ \ \ --- - \ \__ - ) I I \ \\I \ / /h / \ -_— -- z===-N�N \ \ //// - --_- \\ \-_+-=aso -+ �//�/ — - - \\\ \\\\\ / /// p5_ / / I \ \ \ ,� \ - - - _ _ \ s9 \ \ \ z \ �/ / / / J \ \ \� \\\ \ j/ // / - . T - i %/ 5 i �- _ - -- -o- - - o o r�\\\� �\ \� \ + / // so - - _ _ _510 `\ \ = �/ // / /�i - - _ \ \ \ \\ \\\ �\ III / / - / / ) \ - s \ -oss // ) I) I�1 s\\ \ / / / •-�1 f/ _ // /�i52% _ -_ -_-� U_- o' \ \ \ \ / / - _- �\ \\ \ -_-__/ // --\\ \ / /^ \ / / / / \ \ \ \ - - /` �\ - \ / / / // / / /h \) 1/ / // / �'�'L - %_ _ _--- =szs_ LLN I\\ \\\\\\\\ \ \ i/// /ii — — \\\_ _ // // // \ \ \�\ \\ \\\\� 1111 / / / I \ \ -sss - _`ors - ) / l // / / / - / // /l l '') /l/ ll� / / _ // —ors— — _� = W o 00 \ 1\ \ 1 I / /� i/I 5�5_= - - - _ - \� -_ �o/// / / \ \ \ \ \ \\ \ \ IIII 1 1 / / / // / \ \ - \� \ \ \ �of - // /%;� /i/ // l /// ///( ry� _ //i - __-_------ �- \ ����>\ \\1\lII III )I %//i /% os___ \\\\ \\ \ ''///////� �\ \ \\ \ \ �11 / \ / o \ -- \ \ I -\ / �i// -- _ --- z \ \z z // )I / // / / % - -____� _\�\\ -// \ \ \111 \\\\\_II 1 / / / / 55 / \ \ \ \ m m o Q (( // / /// // - - // //�'/, - - `o _ i/ % / O. \ am -a/ I / /JIII II / //�j/ ii ///i = _ \ \\ \ // / / \-.- _ \ � \ \ \ Lo' z // // / "•' / / - - - U \ \ coo / / / o /i�/i// / /ji - szs\ --- \\\ \�!• �\�\ ////// / / \ \ \\\ _ A V A I \\ %� �// 52 ////�� / // /// // //// // /-- - �_--- �� - Av SV A - A\V / �1\ i ) Tv /ice //% 'm l //5/ / �5 �s o'\\\ o / / i////� //ii/ ors- _\\ — �\ �\ \ \ �\ i � 1\ \\l 1. 1 / _ - 'o000 A \ -- - / / // /// /i/ // __ - V A \ I / \ / /j A I \ \ \\� Q \ I" \ OA \ \\\ /5�y5/ /, W, /�_///>�//- -----� _ --_ W" , / /(// / / I ///�/ / /O //�/ ��� -- - VAA -- A�\�VAA�\ \V /�l,II _ \ , I �, I I \ JAI \ - / -/ ---__ A V ) ll A �� �c��co� oo \\ \ /ss\\ vv / � I� , / / - _ - �,// // ///52// -� --- - wv \\\v A / - 1 \ \ \ �n m I v I \ \ \vv� \V / / i�// /_ — vv I I l// /�////i ii//�/ I A \ l i v / / /�--__ 1 n 1 o�r1 � VV AAVA \\wvv� AV AA /(ep ��/// /i/ //i- _ _---_ �� / / // / / / / / / / �5� - / ) h / / V A z \ VA v� vvvvvvv VA \� .v / / �/j // s4o= _ — - - _ - _ v s� v / I I III �I11/ /65-i /, �/�_ z I \�\ \ V A �VAVA V / / / / // _ - THERE ARE NO WETLANDS / /// "'/ //�/ I \\�/ ///,�j//��/ i CALL BEFORE YOU DEG... �T S THE LAW. GRAPHIC SCALE - — �w v / , I 1 I) v v vvwvv T, v vvv v ,vv ; , // / /i / )� v v , /�//� / / - - v v - - - / / / / / co o, / / I 1 \ \ \\ \ \VA\ VA��, \ / /�//// / _ —LOCATED ON SITE AS DETERMINED , / // /� // //// //�/j//�//�� i // 100 o so 100 20o aoo / / j i - \ - - / / /i / / / / z r� X / / / // / / )AVA ) A \"s) A I A \\n\ �/� // /// // // BY PILOT ENVIRONMENTAL INC. ON / /// / j A ✓ // //j / / // CALL N.C. ONE-CALL(1-800-632-4949) / / // /� � 5j0� \ VA \ \ � / - / / � m _ / I // / // /� - - AUGUST 26, 2019 AND ACCEPTED , /�/ // / /�// / / // / // / FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST —sss— - / / j / _ / / / � 0 0- �- / / / / / h ) / ) /) / / / A / / /�h//// / // / /� / -� BY NCDEQ ON SEPTEMBER 20,2019 / // / // ////,C j / } t , , / / / / �// / / ////// 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. / - -_ - \\ - - / / / / � 60 / / h� / / / / / \ / h / _ /� - /o / / / ," / /" V �s 1 II /// /� Mo // / NORTH CAROLINA GENERAL STATUTE 87-102 - / -� v--- / / / ,5�0 / / / � /Q / 5/ / / / // ///// /// I I II \ \ ///�///�ii/ -- A I I �/ /� / v / / / / / / / / - \ / �l / // ti /\j//��/ / /l// / ///// // / �// A \ v - / / - / � / /i / / / / l I A /l //// / / /� / ` v ) I / / //�// // ,i /� / // I11�/l�//// / /� // �/ � IN FEET ) / /, / / ,/ -- vV�\_ ----- / i -/-/ / �/ / // /! / _, ,/�/��//////I/ // I i i l //l/, /,l//X, /oo/,�_/ ���.\, I I I l I//./ //�//��/�� / / /�// /, ,/ /, / /, / //, / /, / 1 inch = 100 ft. 2817 JIM MINOR ROAD PIN# 9802-59-4690 PARCEL ID# 159117 TAX ID# 9-13-5 14.25 ACRES S JIM MINOR ROAD PIN# 9802-58-9583 PARCEL ID# 159116 TAX ID# 9-13-4 13.71 ACRES PB: 073 PG: 0293 nDnn �J ■ U n n n ��{ I""IL5� � gO 8 .Q) o C i .� U W r "I i cz U � �NMIn@j � N a)co��= N O ^: W , /\I� U c,U�I� z � * � U ��, N � CZ c v L_ W .. 2 N20-LLLu J CM W N W � zW WU Z Q a= U Z v CC _1 • •f f • C In 0 0 0 U U a= Z O Z 2 � 2 O O O OU O � U Z U LU E � � O � w U � w (n � � � oc 0 O oc oc Lu Lu Lu � Lu Lu 0 a_ocwILIL rn_ rn_ rn rn O Lu o O o O r- O O r- O o N � 6 - N O N � - 0 Lu - N CO � LO DATE: AUGUST 29, 2018 HORIZONTAL SCALE: V=100' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 WORKING THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. PRELIMINARY SUBDIVISION PLAN P:\17-002\17-002 Drawings�Working\17-002 Working.dwg, C2.0 - Exist -Demo, 2/6/2020 8:53:10 AM N u 0111111114 �C A, wy Sg VICINITY MAP I"=2,000' (110Z) SB aw-Q7Yo ON BRANDYWINE DR O,p 1,- 10 s "i____ I E SE ACK 10' SID No 20.0' g0.0' 26.0 o 1 n � � I p 1� �0 T 1 Z Cn SAMPLE LOT 1 v 10' SIDE SETBACK I 1 6 10.0' BUILDING SETBACKS: FRONT (MAJOR COLLECTOR): 40' FRONT (LOCAL ROAD): 30' CUL-DE-SAC: 30' SIDE (STREET / CORNER): 25' SIDE (NON -STREET): 10' REAR: 20' 20,000 SF LOTS BASED ON PUBLIC WATER & PRIVATE SEPTIC TYPICAL LOT SETBACKS F AK(;LL IU#J I /UJUb, I /U,)UJ, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I/ ��� �m / Woo o + \ + +'\ + + +/ + \+ + + d �oDco ��r000 a:/ /./ n _j LLI n �0000 nn Mo \ mom ; W Q Cfl 0 N D 0 - __ - t _ w ^\ U /'00awowno(o� ' \<�s g �dM3Al�a--_l � +\ �+ + ++o Z 00 °' m PROPOSED / _ _�3i1 b �O I - - - L�/ �\ \+ + + = w Q o ACCESS - - - - / Q \~ Z_ EASEMENT I I I \ / + \ + _ :+ + + \ + + W r m:t Co c_ CLEAR OR GRADE SIGHT TRIANGLES X - / \ w 1 \ + + \ + + + ■L N O I@) TO IMPROVE VISIBILITY IF NEEDED / / // Co J r- R200.0' CD C`7 10'X70' SIGHT 0° 00 �_ � \� \\ + o- i + + ^�,, (n N C.0 Co 0 TRIANGLE (TYP.) o W N �w �� \ \ + w- + + W CV �, (� / , Y i' \ / Cn Cn NCDOT / !� 4 m DRIVE / 46 Z a \ R135.0' + / + + `+ + + APRON ° / r i ; a_ a_a \1 I + /+ + / / J + + 0 x ,�e / U CZ 1 Ld R200.0 PATTON MILL LANE / PRIVATE ro 50' PRIVATE / i + AREA OF DISTURBANCE _ / R100.0' \ RIGHT-OF-WAY PRIVATE 295,504 SF STORM EASEMENT OR 6.78 AC PEN SPACE ROAD 2, oe SF nc ° \ �� \ (10' OFF SYSTEM) �,o° sec9 �•1B \ \ \ R150.0' l / J / / STREAM BUFFER CLEAR OR GRADE SIGHT TRIANGLES / 1 I \ \ - - - _ _- 7776 _ / �/ TO IMPROVE VISIBILITY IF NEEDED / \ \ �• / _ - -7 -m 8+00 10'X70' SIGHT /'�� / TRIANGLE (TYP.) / \ / �� / \ 3-moo_ O I I O OPEN SPACE \ I 506,371 SF 20,000 SF : 4,655 SF 11.62 AC TOTAL \ 20,000 SF WITH 1.36 AC IN R 0.46 AC 0.11 AC r ^0. R30.0' \ 2 �� °'� AC '`'� R175.0' PRIVATE PRIVATE R/W $ \ O \ I I / / STORM EASEMENT 20,000 SF O 1 I,10' OFF SYSTEM) / 0.46 AC \ / 20,000 F 0,46AC h /\ 24.000 F \ � J L_ � / / / •si9s 0.55 AC o m � 26.0' •ram ' / /�/ \ \.o O R175.0'. 00 / \R200.0' ,�3 / 20,000 SF i 00' \ \ P6 ' CR sr rgr 0.46 AC ` 8 +p0 '�+oa \ 20,002 SF a 0.46 AC / 0_ ' 20.0' m /' 21,774 SF •r 9'0 0• .09• r� \ / 20,000 SF \ b\ W Cn 0.50 AC / / rs�� / «<r \ 0.46 ACof of 00 / / �,1 � \ R30.0' co i Fb J l O FUTURE GRAVEL PARKING \ ' °° \ \•t sr / 20,001 SF ry / OP� O/= LOT WITH CONCRETE \ / s I \ .� / 0.46 AC00 / R R O zb� HANDICAP SPACE AND y /n^ �`" +°° o\ \ J 20,00o SF \ M\N01 c� ISLE FOR TRAIL ACCESS 200471ACF z O / M 2 / $ 19 R200.0' 9+ 3.30 R384.2' ( / / o.as AC S� �\�G �b�9s / ./ PUBLIC 20.497ACF \`sf\ P /� / \ / I STORM EASEMENT / °'oLr J /NIS 10' OFF SYSTEM, / ti°n / /� O o' `� / ��' ' 24,077 SF(" TYPICAL LLI ,�04 / / e'�•AA ,0.55 AC 26.0' a',00 r Ozv ,zr •sty / / ml \ / 18 / / \ 2F m 20 L� \ l I al ,478 SF srr\ R35.0' b R48.0' 11 /\°rq>22 \ I o I b \ 0.47 AC �� • / / / I \\� v+` \ 0.46 ACI /\ Lo \ \ \ 24,720 SF 0.57 AC !o\• 27 N V 20,057 SF // 16 / I �; a .es•,9, \ •s 0.46 AC O rb / \ \ 20:329 SF 4/ 20:000 SF 26 z0,255 SF \� oa7 AC / CONCEPTUAL WALKING / oas AC 0.46 A0 / `/ / TRAIL IN EASEMENT \ / ►r A5' R63.0 \ JI R150.0' TO BE DEDICATEDA4o \8� ! J� o a, �`• \ \ / c& CONSTRUCTED BY \ / �! \ i 20,557 SF / C \ \ ✓ ��" THE ALAMANCE COUNTY \ / 0.46 SF / \ cn 32 o.a7 AC o.as AC �� \ �. \ O \ \ / / / / \ , TRAIL SYSTEM ���� O V��6- O� 30.802F AC . / (IV \ \ �.`�/ H r7 r7 JS OD < N 6cQ C✓ p \ Z ' Q .Op�ot \ / ,eA „+ O' <ta9 12 H U) pry M N K% y� �. •• ��� A80.93' qY 39 26.0' PUBLIC / I \ n � I Cr 2 CS% "b. \ �C/ d- / \ \/ °0 22,634 SF 0 0 0 ,.� w o N \%gip o \� �y Q / / Lv � o t STORM EASEMENT, 16 CLUSTER MAIL BOX / I r, \ 0.52 AC W O I w - o Q / :10 OFF SYSTEM, rnornw�r•> ai 24 R35.0'. os o o \ / �Q , o I O J �, TYPICAL ON (GRADE KTOODETAIL) O of N m (� 20,557 SF 1 / 2046°ACF I^ 13 \ Q m X o = W \ / U/ Ct/ 0.47 AC I< ,op0 "\ \ I 20,000 SF / Y za / I J o ? /� ry. I 0.46 AC m�\ o 9.07.°9' f e 11 a j 16 CLUSTER MAIL BOX Fez, I m / r",y p7g R48.0'bi 8" THICK CON. PAD �_ - / K Q- / \ gse`" A3 R63.0" (GRADE TO DETAIL) 4109 tb9.70 / Q 73s.90' Lo / UQ Q Z 20,556 SF 0.47 AC \ . � N OPEN SPACE STREAM BUFFER W (n \ / ryo'` / I I \ \ 20 522,744 SF w W _ / ,/ "T / 12.00 AC 8 STREAM BUFFER + 20,000 SF LL, Np�0p0'S, 0.46 AC / + oML'I�NI8 I o-Ln-Y _C C), 20000 SF �e + + + + + + 0 I")W e _ �:: • • _ Q °o 6 Q w / / o.as AC I 20,000 SF ` / ' j STREAM o0Z o-= \ I /. O�<mo I / + + + + + + + + + + + m m W W 00 Ln L0 CALL BEFORE YOU DIG... IT'S THE LAW. CALL N.C. ONE-CALL(1-800-632-4949) FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 p158.88' / •�/ / / J �I .01 Ljj o •'.� I U ' 965.84' •• / O 0_ U Z m of ��rnQ m �. i Lw c� I� 00 Lo of _ oo 0 CO � 00 Zm�� U-)I > o THERE ARE NO WETLANDS J � 00 LOCATED ON SITE AS DETERMINED w C6 BY PILOT ENVIRONMENTAL INC. ON Ljj of o AUGUST 26, 2019 AND ACCEPTED Q BY NCDEQ ON SEPTEMBER 20,2019 Y J O of J + + + + + Lf)Ljj + + of N M N 04 wa- u� N + / Z�o wo0oo 00Cr- Z 00 Q m Z Q / C.000_� O m 0_ PROJECT INFORMATION: OWNER/DEVELOPER: ROBERT M. BRAME 2863 SOUTH JIM MINOR RD MEBANE, NC 27302 PROPERTIES INCLUDED IN PROJECT: 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD PIN# 9802-59-3969 PIN# 9802-59-3974 PARCEL ID# 170308 PARCEL ID# 170309 TAX ID# 9-13-183 TAX ID# 9-13-184 2.8 ACRES 3.3 ACRES 2863 JIM MINOR ROAD 2817 JIM MINOR ROAD PIN# 9802-59-5721 PIN# 9802-59-4690 PARCEL ID# 170310 PARCEL ID# 159117 TAX ID# 9-13-185 TAX ID# 9-13-5 1.68 ACRES 14.25 ACRES CULBERSON LN S JIM MINOR ROAD PIN# 9802-58-4657 PIN# 9802-58-9583 PARCEL ID# 159114 PARCEL ID# 159116 TAX ID# 9-13-4A TAX ID# 9-13-4 6.01 ACRES 13.71 ACRES TOWNSHIP 9: THOMPSON DEED/PLAT REFERENCES: DB: 2823 PG: 0093 PB: 073 PG: 0293 DB: 3239 PG: 0957 DB: 2487 PG: 215 PB: 073 PG: 0293 SOILS: CnB2, CnC2, CnD2, CnE2 = CULLEN CLAY LOAM = GROUP C RvA = RIVERVIEW LOAM = HYDROLOGIC GROUP B WtB = WYNOTT-ENON COMPLEX = HYDROLOGIC GROUP C FEMA MAP #3710980200 K, EFFECTIVE 11/17/2017 FLOOD HAZARDS PRESENT TOTAL ACREAGE: 41.74 ACRES BY SURVEY TOTAL # PROPOSED LOTS: 33 LOTS AVERAGE LOT SIZE: 0.49 ACRES (NOT INCLUDING LOT #33) TOTAL OPEN SPACE: 530,223 SF OR 12.17 ACRES WINDING CREEK TRAIL: 316.09 LF FOREST CREEK LANE: 1,186.86 LF PATTON MILL LANE (PRIVATE): 1,271.77 LF GRAPHIC SCALE 80 0 40 80 160 320 z w W• W z 'i�" IE U z Y_ \\\\\\ d J 0- 0 I� 0 L) C/D o �� H-�■I L) E-I V) W 0 � cc �L) L) I� w w al w OU 2 2 z O O D Z U C) w oC �5 O oC Lu U -- w cn 01: 0 oC 0 O oC oC w wwoCww 0 D_ OC Lu D_ D_ rn rn rn m 0 w o 0 0 0 CM 0 N N N N N Q ao co co co co 0CM7 C:)O C:)O O cm,- O Lu r N Co Lo DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=80' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 WORKING THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. CQo) o 0 ':\17-002\17-002 Drawings\__Working\17-002 Working.dwg, C3.0 - Site Plan, 2/6/2020 8:53:16 AM ( IN FEET ) 1 inch = 80 ft. PRELIMINARY SUBDIVISION PLAN F'AN(-LL IU#J I /U,)Ub, I /U,)UJ, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I / H aw0_r)0L0a0 to + 00 LLI 1 \ oz�OfmJa-� 11 ++ 1� SIDE SETBA No 2p.0 CLEAR OR GRADE SIGHT TRIANGLES a_/ _ FL w + \ \ (� J TO IMPROVE VISIBILITY IF NEEDED NIA \ \ \ nnnO 26.0' 300 , ran �/ J�c°� ° 1� 10'X70' SIGHT / 0° 00 LO 00 \ \ \ m NI TRIANGLE (TYP.) N \ o mp 10 1 Z SAMPLE LOT \ cr 00 _O ➢ /� O�W� rn x I / JZ*k� CO \2� NCDOT w �za� \ �W O I DRIVE z V� I w \\ U 10' SIDE SETBACK APRON Ld + + r7Ld+ + + + + \ \ 60.0' 10.0' i ° 20.0' + + + + + + + + + + + BUILDING SETBACKS: / + + + + + + + + + + + + + + + w i 4 + + + + + + + + + + + + + + + + + + + T (� \ + + + + + + + + + + + + + + + + + + + + + I FRONT (MAJOR COLLECTOR): 40' U O N w \ / i \ 12.0' + + + + + + + + + + + + + + + + + + + + + N O C� U FRONT (LOCAL ROAD): 30' \ \ 1 + + + + + + + + + + + + + + + + + + + + + + L N O CUL-DE-SAC: 30' a / \ w m / + + + + + + + + + + + + + + + + ♦--r Co N C'� Co � w \ \ PATTON MILL LANE Co co O U T \ M + + + 50' PRIVATE + + + + + + + + + + + + / co SIDE (STREET /CORNER): 25' /= \ �j *oo + + + + + + + + + + + + + + + + + / (n N O OPEN SPACE / i 00 \ PRIVATE RIGHT-OF-WAY / ^^,, N Y SIDE (44 ft RI fURBANCE �' + + + + + PRIVATE + + + + + + + + / W >, C) 295,504 SF OR 6.78 AC oos4nc `n STORM EASEMENT + + + + + + + + + + + .ROAD + + + + + + + / (� T T .- REAR: 20' ) / \ \ (10' OFF SYSTEM + + + + + T T + + + + + + + U z O O 20,000 SF LOTS BASED ON PUBLIC WATER & PRIVATE SEPTIC / ,�� 98. \ / i cCZc • • Cz +3a-os- - /,/ / / � V O x 2p TYPICAL LOT SETBACKS / \ \ \ > / _ _ - _ -+� _ _ / / - O W NmL.LW Iry CZ J � d _ _ --- / CLEAR OR GRADE SIGHT TRIANGLES 10'X70' SIGHT / / Z`8Ze \ \ - / /, 5% + + / Co TO IMPROVE VISIBILITY IF NEEDED TRIANGLE (TYP.) \ \ \� � - �� \ + + + + + + Illlr►IIUpj�xx/ Lu C-i . . . . . . . . . 1 to + + + + + + + + + + + + + 33 + + + + 0 z / W 3 £ \ ' + + + + + + + + + + + + + + + + + + 4 OPEN SPACE 1. + + + + + + + + + + + 4 506,371 SF + + + + a 0 a + + + + + + + + + + + + + + + + = u� •• O- O 4,655 SF `9l 11.62 AC TOTAL Z U 20,000 I N 20, 00 SF / 0.11 Ac WITH 1.38 AC IN _ = LL Z o° N 0.46 AC a 0.4 AC zto� + + + + + + + + + PRIVATE R/W + + + + + = U Z . N = J N PRIVATE + + + + + + + + + + + + + + ,Po/ \\ I 5 \ +++++++++++++++ / 0 2 00o SF \ STORM EASEMENT % . • �� R 0. AC 0,000 S s8y0t 10' OFF SYSTEM + + + + + + + + + + + + + + + ii�G \\\���� Z Y M 21 R� o \ \.�s• 46 AC + + + + + + + + + + + + + + rrrr r uaa��� ,� \ `ems\°, ^ >Z. + + + + + + + + a " 4,000 SF 5 AC00 / � / 9 . / m / 9'°� 9h/ so �`OO \ \ \ \ r A 56.1 9 ,9G b 6 <Z99 \ \mob R175.0' \ 4`1 HATCHED AREAS �LE � / R200.0' �4' A \ 06°- ss 9b 0�060ACF 7 SOILS A FORTE SEPTICC EE /0,002 SF ° 9ti 0 EST CR \ 9� \ 46 AC m 1 / 7 - ss` 20.0' / \ 21,774 SF / F ° o•" pg • fib\ / 20, 0 SF / Q / 0.50 AC Ssib / / <<t b \ 0.46 C °1 Ld 00 61 / Ln / .b99< 3%0o /m FUTURE GRAVEL PARKING LOT \ < s%76°9 / \ sb \ 20,001 S ry' + + W / � WITH CONCRETE HANDICAP SPACE �°� /Ni �^ I \ .F9� ` 46 AC 10 yy / ' 0 / O/� AND ISLE FOR TRAIL ACCESS 29 `/ �� \��R200.0' 7gx0° oF69b \ \ + + T i / z / 20.421ACF / 19 \ \ 350 R384.2'\ C O.000AC / ah 21,52 F b rWC r^ 11-11' Fyb // PUBLIC 0.49 A STORM EASEMENT 10' OFF SYSTEM, 24,o -F + TYPICAL 9p.s N o �9\ / + + �c�` P/ 0.55Ld °° ZL'6Zy Ln \ �R35.0' R48.0' .47 AC 20,14 sF STREAM 0.46 A BUFFER \ / ± N Fy O x (D 24,720 SF / / °° \ NI ' 170.57 AC \ \ Q N e• 27 16 �; Q ss•reL 20,329 \ •ss� \ 0,057 SF . 6 AC N 6 9a•s \ \�• / \ O 0.47 AC \ 20.46146 S AC 20,255 SF • \ / � "`�� P°" \ \ \ / 1cv All \ 34,802 SF 0.80 AC o Q CV do > a 2 N CL��in\ 6 O, cn O v> O CL0��O ��o Tgo -A � C" m ���p o i OD \✓ / / / L0 2 Q Q7 Q 0 � J � W ILL W d. W CflN00< It C14 Co NI a. 0 M W O N 0- L0 Y _0 D ,4-0 0)W r11 00 Ld \ L0mzxo 0- / p < W 0_ m J � 2 ~ �9. CALL BEFORE YOU DIG... IT'S THE LAW. 60 CALL N.C. ONE-CALL(1-800-632-4949) FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 \ N SITE VICINITY MAP I"=2,000' � � 1 0 0.46 AC CONCEPTUAL WALKING \ \ \ ;� R150.0' TRAIL IN EASEMENT \ b 40•¢5/ RI o TO BE DEDICATED 20�^� & CONSTRUCTED BY / ,557 S .47 AC \ \ / °o o° THE ALAMANCE COUNTY 20,109 SF Y Y Y Y Y / \ ✓ � \ /X � TRAIL SYSTEM alpZ � � 0.46 / \ � \ ` m U U U IL EL U U � J � 2 \ _ A y 39 �8• x <ZO9 N 9� (n 26.0' V A6o.93 v kaa PUBLIC 16 CLUSTER MAIL BOX \ �\ 2,6 4 SF w /ya STORM EASEMENT, ON 8" THICK CON. PAD \ �s .5 AC ' J 2 I �P 10' OFF SYSTEM, (GRADE TO DETAIL R35.0'� ) z� / 14 I N \ Z O Z 24 °y / TYPICAL ss \ ��• / 0,557 S 20,000 S I 13 \ 0.46 AC a o+°� �9 ' ' 2 000 SF207. \ I " \ �"s R48.0' \ / 16 CLUSTER MAIL BOX 8" THICK CON. PAD (GRADE TO DETAIL) 9g 9Fb A3=6 R63.0'/ \ 43.03' 169.70' 20,556 SF I \ \ o 0.47 AC I \ \ O OPEN SPACE STREAM BUFFER _ 20 522,744 SF 20,000 SF = 12.00 AC , i tI 'o�, 0.46 AC o • / ^ _ 20,000 SF \ �y6' � � i� �� ' • 0.46 AC 20,000 SF \ " . / STREAM \ I I 0.46 AC ' I / j.i. C) + + W A156' L' L 04 N + GRAPHIC SCALE 0-0-r7 w�Lo I 30 60 120 240 / / •� W 00 0- . ' THERE ARE NO WETLANDS z r7 z x LOCATED ON SITE AS DETERMINED ca.� 0 F � BY PILOT ENVIRONMENTAL INC. ON o' ( IN FEET OAUGUST 26, 2019 AND ACCEPTED rr :2 1 inch = 60 ft. ' BY NCDEQ ON SEPTEMBER 20,2019 z 0 w oC w 2 1.- 2 O O U O D Z U C) w U o Z U U w O QZ' 0 oC o O oC oC w wwoCww o rzocwrzrz rn rn rn m O Lu O O O O O I--N N N N N Q 0\0 C\O COC\I CO CO \ � 6 CD CD O O N r O L>LJ r N Co Lo DATE: AUGUST 29, 2018 HORIZONTAL SCALE: V=60' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 WORKING THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. CQo) O PRELIMINARY SUBDIVISION PLAN 17-002\17-002 Drawings\__Working\17-002 Working.dwg, C3.1 - Site Plan, 2/6/2020 8:53:21 AM NAKI;LL IU#J I /UJUb, I /UJU'J, I /UJ I U, I n&1 14, 1 ny I I b, 15y I I/ / / / / / i i / y� X � I I � I A V \ �� �- �' _ --- �/ - � � A __ - - - V V �, ,- - / / / / /W00V I �_ �� V A V - - A \ - - - - �, A �� - -A - - - A�V_ V� VA \ \V�VA / ti - A / / /'� / A A -_ A __ __ A - - - - �� - - / - - --A VA V�VA ✓� - - A� / / / / / \ V / / / I I I I I I I /� - _� V _ A� A V A� - ��. �� �� ���- - - VA ��\ VA A \\�^ \�� / \ - - - - - - A A A - - A / / / / J�� \ / / - - SKIMMER SEDIMENT BASIN 1: - - - CULVERT 2.0: - v- - \ VAA y - v �vv - - O / / - \ I v v - vsz \ / / / / /� - sF - - - - v / / / / / l / -AV �� - _v) / / / / i / \ I / / v DA: 1.135 AC - - -s �� - 33.4 LF 15" RCP - �� - v s vv - - �� - - - - - v FES OUT: 532.00 / / / � / / // A i i , v TOP OF BERM: 549.50 - - - - - v v - - - - / / / / / / / . / ) \ I �� v CREST OF WEIR: 548.00 -- -� -� @ 1 5� SLOPE v APRON @FES: - - - - - - - - v CLASS A EC STONE: vA - - - - / _ 1-/ / \ -- Z / i \ LENGTH OF WEIR: 5 _ �,, \ \ \ 5'Lx6.25'Wx12"T \ - - ' - , / / / �/ / / / - A / �j� - ROCK PIPE INLET � -\ v 1-1 \ v � - / TERMINATION POINT OF EXISTING 8" I - I / s / DIMENSIONS ®WEIR• 52 Lx26 W �� v _�_ v\ - v -_' A � /A v A__ -�I --vv."v v vvvv V \ \��s - / ' ORANGE-ALAMANCE PUBLIC WATER MAIN (PER i �� � - / / . / v - - / - /� %�PROTECTION y �� \ V AA V \ \- O F _ 'I -DEPTH FROM WEIR: 2 - - - �� / / ORANGE-ALAMANCE). FIELD VERIFY PRIOR ( = - / (����� �� / / - - / I I I V �i 3 BAFFLES REQUIRED - - - � - - - �� � " �� V A� / v - - \ /-- -- N 'L�\ \ \ \ \ \ � �� ��tiZ "N / -� / I l -� -��� C -��v\ \/v - � - -- - r .� TO START OF CONSTRUCTION. cos - - _ vvV/\v vA V \ _ �� / A te/ jyy�'F�G /��--- / / �/ �' \ \ / , - - � sys- / v ��s 1 A_\��L� v 1 / � / / � --- � v Fesy \ / A G AG F �p .c�v-- i - / - - / / / / / / \ s� - - v PROPOSED A \' \ 1v vL �\ � � - V A� \\ - ---- A o A ��E 9A �� / / i -/ / / -----_--- - ACCESS \�� \ \� �� -�_�Z \ p0 c^ ,� / / \ \ s / - \ \ -�;" � - 11 \ '9 - � - - - - - � /j / / / / - - - - - -� EASEMENT \ �' \ \ \\\\ \ \ / �/ 0�\ \ -_ - . - - ' / / /h� / \ ORIFICE SKIMMER W� 0.75 DIA �' � V\ \ I \ � \ \ \ \ \V A v v V _ wA �v A \ /� / - / //h° i A /.\ \\ \ N \ \ \�V vv A �� OUTLET TO CLASS A EC STONE: - ✓/� A v A o_ N \ \ \ \ \ v A i-1 l� \ A - �E - / ---- // / --v \V \ V A \ \ ,-' *� � - - - � \ \ - _ - - - - 5�0 - - - - �j ���/ v � 3'X3'X12" DEEP APRON / v_ FES IN: @FES: V o �� \ \ \ CONSTRUCT AND ` V - - - - - / j j - , / - + 1-1 � v \ / APRON @FES: \ I \ \ \ \'\ V BACKFILL DRIVE PIPE I \ < � �� \ \ \ - - - - _ - - - - - - - - �i _ _ i / \ - - V V / CLASS A EC STONE: �\ V A V A \ \ \ NLDET INSTALL ROCK I I I \ � - \ \ \ - ---- --- -- Z% � / v v v A \ /A 3.75'Lx3.75'Wx12"TV A V I ��/ � - �E� v \ v- -- - - �/_ l l --- _ �v v / Z \ \\ \ \ \ w � - - - -stis� - - -o \ \ \ \ l . � _1 v - v v \ _ - - - -- \/��� / �i l / v v v v A V I_ i V \ \ V \�A \\ V A PRIOR TO GRADING \ " A a_ � - v v - - CULVERT 1.1: - - - - , 1 A j -/// x -� - \ - - -_ v� V I_ v v / \ PRIVATE DRIVE �� �� - �,� v vvvv y�vvv �vvv\vvII y I �. ) v - DRIVE PIPE ----v /� / / - - -� � v vvv v - - v \ \ V A \ \ \ \\�\ \\\\\\VA \� V I I I I I I � - v / i /� � / � - /- \ �v o v vV A \s \ \ +� V v 45.5 LF 15" RCP , / � � - .� \ \ - @ 0.57% SLOPE ,--\-/ 66 /� / // / \ h°� \------- �\ \\\s \-- \ \ \ \ \ \ \ \ �'\ x �� \\ \ \ \\\ I I / I / \ ,� / i ;��� - - v v A - - _ SEDIMENT TRAP 1.2 \ . s k\\ �\ \ \ V A \ � � 12 X50 CONSTRUC1ON ENTRANCE __/ � ` / of ) I _ - - - - - v� � - � � v DA: 0.39 AC A \ \ \ � � V'_ °off A \� V A \ \ V I I i I v �i �� ,�' i - _ _- �__ _� v �`s�� -_ - - \ \ \, �t VA\ VA VA\ TOP OF BERM 530 50 / � V � / FES IN: 548.36 � I / / v A v __ � �__ - \ \ A A \ \ V � �E i _ - - v v v - -CREST OF WEIR: 529.00 - A � \ \ \ \ / 1 / / / - v > A \\ V A \ \ / APRON @FES: � � �'� -� � % � / v v �� v � \ '\ \ V\ \ \\ �, � \ \� j � - - v � v � LENGTH OF WEIR: 5' - - � / � \ \ \ , \ \ 1� I � � \ V A \ \ \V A A� V A \ \ \ / CLASS A EC STONE: / \ v ( \ - - - / \ \ \� \ \ V \ V A V A / \ \ 3.75'Lx3.75'Wx12"T \� �/ i A � v \ / - - - �� - v DIMENSIONS ®WEIR: 34 Lx17 W - - - - / A V `� V A \ \ \ J / V / h a FES OUT: 548.10 � A - - - - - v -- v - DEPTH FROM WEIR: 3.5 MIN - _ / v A \ I/ / / _ i h - \ ---- A �l ICI \ VA \ VAA� V A V\\ / ' �/ - APRON @ FES: \ \ \ ` - - - YARD INLET 1. 0: 3 BAFFLES REQUIRED / / w, *' i A / CLASS A EC STONE: v \ V \ SEDIMENT TRAP 1.0 - - -� v / / \ \ \ \ \\ \ / / l ss� / � \ - \ - - - - - i l \ \ � \ \ \\ \ / A _ _ _ e WEIRS: 526.90 v -oss- / I n \ \ \ �V A \ i o / vv v CREST OF TOP OF BWEIR: 0529.00 - v - v - N V OUT: 52 �0 \ �A - - - - / / / / / % A 5'Lx6.25'Wx12' T A v / / o / r ROCK PIPE INLET \ v v v V A \A 1 I / � // o -- ---- �� � V A I� I �II\ 1 TAILDITCH ALONG ROADSIDE AS PROTECTION / / y v \ v v v v� - II A \ \ \ \ "' I \ \ , / /// ✓� �� - -\ - A LENGTH OF WEIR: 5 � v - - - v v A v v \ - - - - - - - / ✓ NEEDED TO INSTALL CULVERTS / / - a � v - - v \ v V� �"__ v v v v _ A - - - / �� III V A \ � � / i \ - \ \ \ DIMENSIONS ®WEIR: 34 Lx17 W / \ - \ \ - - - - - - - AND DIRECT ROADWAY RUNOFF i v -_ \ \ V v - - stis_ - � A \ \ \ \ / TO SEDIMENT BASIN / - i 1\ „+tT - \ / - V - v - � V A \ - v - DEPTH FROM WEIR: 3.5 MIN / - / / - % / l (i , j /� _ 11 v 3 BAFFLES REQUIRED - v v v v v - - - - - _ / \ \ V A \ \ AREA OF DISTURBANCE _ ✓ ,/ / it / - -� - � V A \ \ \ V , ) I \ I ' / / / - ' v - - - - - - - - / _ / / I \ \ � 1 I IIII \ /' i 295,504 SF OR 6.78 AC � / i / / �3: \ � � � sss \ ' \ \\ \ ) 1 I I IIII / ( / / _ - - , " \ - \ \ - - - - - - ;' / / 1 1 I \ / / \ I 1 / / / �' �iJ 111, / h I / - �: �� - v --------- / / II \ � / 1 / -' / s I J l -- - �s- - Gov - - / \ \ --- / , - /- �° , y , (I\� (\, --- -- s£s- - .=_s_ // / I I fuoz) sa ava-arar� �nr \ / / / V /ss V �� / -- -� - / / / S tW -11 �) �-�1 v / / / i // vv �, \ �` �� \ I� \ ����,,=���;, So _ +v - - �o / / I /// /A E V / / z / , - A \ \ \ �_ o - - - - - / r vv A �� � � \ \ \ V A / / % y � �_ :777 i / / / /�l/l R \v V \ \ / / ° n V /- A \\ )j �. I I -1_\ � -\ � \�- �. < ��A \j ---- _-- -- �/ / / ///�j/ \ -� \ \ \ / / / �� 55 / s \ l v \ V A\ x x° _ - - - -------- / / / �/j / ////� v A \ % �' \ \ f \ \ \ n 5 5 - -_-� / - - - / / \/ // \ \ \ 12'X50' CONSTRUC110N ENTRANCE ' / - / i i - A\ / � � / A A V A �A A b ,� sti �/ - - - - - - - - _ _ _ _ - - - _ - - / 11 / j�j�/i/i i \ \ \ / o i / _ - / ) \ -- \o"' V v �� Aso \ / v' �zs� � - � � ----_ j --�v�l/�\/////� jI v / i' / / � ,v A / IA / v v v v ;' / - --- - --- --- - - -ors - / ///-�v\�\)S 'z II \ \ \ \ / % // \ \ \ \ \ \ � \ \ \ 1' ff ='7 - _ - _ - - -- _ � - - - _ _ - - - - �/ � - - //�// / /// b9� \ \ \ \� / /, _ /ii \ \ \ \ \ \ \ \ _ . - - - l / 1 ;; ; v -CULVERT 1.0: _ - \ SEDIMENT TRAP 1.3 - - - - - - - - - - _ % � --- ��//, / \ _ ^` �%/ / ROAD GRADES IN SOUTH JIM -_ O � / /j A v V A V - �� '''� - - - / _-__-� � _1_51 /\ / �� / // y I / \ \ V A �'�� - / - 71.9 LF 24" RCP - - ,DA: 0.28 AC - - - - - - - ////;j /// /_ i MINOR ROAD ARE APPROXIMATE. - ` - / - - - - - / -// / ////// / / \ -. a / -� \ \ \ \ \ \ I I / _ -_ - - @ 2.09% SLOPE , - TOP OF BERM: 524.50 -sas- �/ // / iii V /11 / \ \ NO GRADING REQUIRED EXCEPT - - A ;� - - - - / -_"6'< �' / // \ AS REQUIRED TO RE-ESTABLISH � � '`�` i � " V A V A \ / I � X , I I I I I I I I I V A I V - - - _ - - - CREST OF WEIR: 523.00 _ - - /-/�� /i/// I / / j / V A V A / SEDIMENT TRAP 1.0 A \ 1 A �- I _ - -LENGTH OF WEIR. 5 - - - - - - - - ��% %/�i / // / _ � V \ GRADES ALONG WATERMAIN AND � FES IN: 538.50 \ \ v I I \ I l - - - - - - - - - - _ �� �i/_�' /// // /�i V A DA: 0.34AC \ �� \I �\ - - / / / \ \ \ AS NEEDED TO REPAIR - - � 1 i1 APRON @ FES: A v / \ \ - v- v DIMENSIONS ® WEIR:35 Lx17 W _ _ _ i�Z / ��//// /// v - ,I / v v v v v v v v------ / / / TOP OF BERM: 525.50 FES OUT: 522.00 r- - - - - - - /i %� �/ / // / \ \ \ \ � ROADSIIDE DITCHES. i / - - - CLASS A EC STONE: / \ \ \ DEPTH FROM WEIR: 3.5 MIN _ __ � � i / / / - - - -- -CSC i /\5 / / V A v - - - � - 1 i / 4.5'Lx4.5'Wx12"T \ \ V A \ \ / / CREST OF WEIR: 524.00 APRON @ FES: \ \ VA V I I � -o�_ -- _ -- 5 3 BAFFLES REQUIRED - _ - , �i5 /// Z/ - j ///// I \ \ \ v s� i \ \ \ V A / / LENGTH OF WEIR: 5 \ \ \ \ V A - _ - v� �� v - - - i % _i/�i_ �ji ////// // \� \I \ i CLASS 1 RIP RAP: A� \ / \ " \ 16'Lx18'Wx24"T V A \ \ \ \ \ v ✓i / /// / CULVERT 5.0: r \ V A \ / / / DIMENSIONS ® A V - v p \ V A V A V A A / - 1 - - - \ \ b� / WEIR: 40'Lx20'W 800 SF \ \ \ \ V A \ \ V�\ \ V �\ \ \ \ - - A _ � �i i / // � / oo, //% \ \ �` � / / 54.7 LF 18" RCP \ \ � / \ \ \ s' / / / \ \ \ \� \ \ \ \ \ \ \ \ \ - - \ - \\ - - - -� � / /ii �i i// Z_ // //•'j \ v A -. i i a - o / @ 1.01% SLOPE A / DEPTH FROM WEIR: 3.5 MIN \ V A V V \ V A\ \ \ \ \ VA w -- v - - - - -- � �� / / \ V A A _ � i �� �o /" / - - - - v \ sP - _- - A / / / / 3 BAFFLES REQUIRED \ \ \ \\ \ \ \\ \ VA \ \A � \ - - v v - - - - �/ - - ✓ /� // j / /,� \ v - - \\ \ \ V\ \ \\ \ v - -�_ --�- /� / / \ \ � / - v A s�� �� A v v v / / / i A V \ \\\ \ \ \ V A \ �s�\_ �- � - - - ' - It> / - i �ii // \ I I I I \ \ \ v � / \ V - / / \ , \ \VA \ V A s \ - - - -v ii �/ /// / / . �- I -<- - A / y� - \ \\ V A\ / --- v� v - / A I \\ s\ \ �\ \\ \ \ \\ \ \\ �_- - // / //i ii / / / \ \V A - i \ \ / 55 - vv - / / / I �A \\ V A\ \ \ \ \ V� \ \ \� - / ;_ / / / / �. /mow - v - / / _ \ \ \ \ \ A \ V A \ V v V A \ � - ��%� / / �� / . \ v --� \\\ V \ V �\ \ \\\ \ \\ \ V �- --- �/ �/p / \ v -sas / / / \ \ V A �\\ \ \ \ \ \ \� A \ \ \ V A - - - - _ / // / I 1 -y - I \ \ - �_, - V -- --- / _/// / , \ \ , o �u. / �� - � - ° - / I I � I V A M \ \ \ , A \ \ \ \ \ �A V - - - /// % P / \ - - - / i ' / / / \ \ �, \ \ \ \ \ \ \ \ \ \ \ moos - - - 0( - V A V I --_v i i / / / I � I I I \ 1/ vA �\ V A\\ \ \\ 1 \ \ v- - % �` -- �� / / / / / / �t �tA\\1A�\ V\ - �/� / / / � � v; _ _ ---- \ i i / // / l I I � SEDIMENT TRAP 6.1 I I I � - /� - / / / / ��I \ / ° . ��� � -� - \ \ v v - - / / / 1 h I50 AC \ V'495_ ' i � �' I - v � / / / / v� - -- / / / y �/ / ROCK PIPE INLET °o \ - - - - \ \ 8 / / / / / / TOP OF BERM: 534.50 - A / / - PROTECTION I \ V - - - A \ �� '�o�� °ss / i \ \ -_ / / / \ / / / / / I CREST OF WEIR: 533.00 I / / I � i / I / no - - \ s� v ' / / / / I I / LENGTH OF WEIR: 5' V I+ / + \ + T . • / ✓ / I �" \ - - - � - - - s \ \ v A / �� / / / / / / / / DIMENSIONS ®WEIR:44'Lx21'W \ V / /\/ / /� � / FES IN: 537.00 1 �� / / I \ \ _% � � . . / / - - - J I ( APRON @ FES: / � , /'�%, h� FES OUT: 537.95 \ � v v � � � / I i I I I DEPTH FROM WEIR. 3.5 MIN � / - v v / �I I / (/\ / i �/ * . / - / / I CLASS B EC STONE:, �,„ / \ (RED � � I I I / / / - l APRON @FES: - v �, �� / / 3 BAFFLES REQUIRED % / \ / / / 6'Lx6'Wx18' T I -/ CLASS A EC STONE. V - \ V v v ors / I f / / / 555 �- � , � � I I / / ' / !ll/_ / / / / I I �� �; 6'L<7.5'wx12 T V v v - �s f I I / C� . / / / I I SEDIMENT - v v - v - v A V v v\ V �� A �� 's+as.so ��� N \ \ I ) / l� / / / p F � +E / / CLEAR AND GRUB ONLY AS NEEDED TO I I FENCE I %/ _I - v v v� v A \ V A / -F I I � � I \ \ \ V A \ \ V A I I I I o / / �`� / / / � I I �� C� / / PRDRIIVE PIPES. INSTALL VPE (METER " - - v \ v v v v / I I I C \ \ i I � 9 �� / v l \ \ \ /a / •��� / �� - - \ s \ \ \ \ V I I I / 1 �0 / o / (I I - V- \ \ o� v v v v v � � ��- s"s �, A / i P \ \ F��� / / DIVERSIONS SHOWN PRIOR TO INSTALLING % 51.9 LF 24 RCP( -- \ V v s v v v 1-1 v A \ V �\ \ \ \ \\ \ sVA/ �` / / 'L G ti CULVERT 4.0: \ \ V A \ \ /( / / / CULVERTS AND DRIVE PIPES. UPON I / / „�' - _ \ \ / v A v v \ - / �� �( '9 V, - / / MEASURES, BASINS TRAPS AND a I III - \ \ \ \ \ _ A A \ V A \ V A\ \ I E y 2 0 s� �� \� \ \ \ o /I /•. / I / ;; . A \ \ \ \ \ \ \ \ \ \ /�� Pam' A O t^ �, N / / / / COMPLETION OF CULVERTS, FOLLOW / iF' + / - FES OUT: 536.00 i�/ - v v v \ / \�_- �\ \ \ V A V�\ \VA�VA �\ V A\ Vv V A \ V A\\ \VI I �// / Q�••/ \ I \ \ / / / SEDIMENT AND EROSION CONTROL SHOWN / / \ \ V I / / ON SHEET C4.1. � / /� / / = -' APRON @ FES: v v - v \ \ i 1 A V A \\ \ V AV : / \ \ V / 55° / / = ' CLASS B EC STONE: v v - v v A \ \ �xs �\ \ V \ \-Z VA \ \ I / -- I �/ � / - \ \ v i/ /_ I A \ \\ 1\ \ �A �I I I� �F!•/ I - � v � / v �� v vvv v v vv vs, vv vv �v vv \\ \ I // ��j \ / \ V I / / / / / / / I / / -- - 12'Lx14'Wx18"T v v v \ V A A \ / , / \ \ \ \ V \ I / ( \ \ \ / __ v v v / � _ v v v � v vvv v v v v vv vv v� \ V A\ \ / \ v v V / \ / ---_/ / / I I j // /� /jv \ v v � v �� v v vv vvv VA VIII /-- V I \ , \ / - / / v STREAM �A \ \ / ( \ v - v v v v v v v Sys / � \ vv vvv vvv I 1. \ \ / \ � \\ \ \ \ \\ BUFFER \\ \ I I / \ \ V A \ / / / /SEDIMENT BASIN 4/5: v v \ v / i / A v v V v v v� V I I / \ � I ( �� v v � � v v vvsv v v v \ V A \ \ / V / / w i - v v A v \\ -- - DA: 6.42 AC V� V A - v V AA v v vvv v` V AV \\ 1 1 I l 1 V A v V / - / N \ TOP OF BERM: 536.50 v v v - - - G' v ", \ V v \ \ V' v v vv v v vvA VV \�\ V \\ \ \� 1, I I I 1 V A \ \ \ V A - A \ \ V A \ / / ' I i ( I I \ \ CREST OF WEIR: 535.00 v v A � - - - � s A \ \\\ \ \ VA\�\\ \ 0 A \ - �� v V A \v vv v \ \ \ \ \ \ / �- l ,�, l iv A \ V A V A - 8 VA iA v VA- vvvv �\ V A \ 50 \ V A V A V A \\ \ \\ / � - - / �I / ) 1 ) / / /�N V A \ \ v LENGTH OF WEIR: 12 v v V A - otis - - - v r ������'- \ �\ \ VA v - V- - A A \\ \\ \ \\ // ��C V A \ - - - - �__ v / / SEDIMENT \ \ v V - - - - - - - v v - - _ - vVA \ _ \\ \\ \ \ \ v �� \ v y \ ss� V A \ \ \ PROTEC110N - / / % � I I / FENCE \ V ' DEPTH FROM WEIR: 2.0 MIN \ \ v v - - - - - - - - % � v - � _ v \VA� \ VA A \/A 1\/) / (, v A \v v v - - - - - - - - - - - = \ ( \ v \ \ \\ V / �_ / ��''" / / \ V - 3 BAFFLES REQUIRED � v v v v - - - - <<- V /(��-_ - �� \\V A / - / - - - - - /� /\ \ V A \ V A ( �� / -- vv i / / / / I / // // - - - - \ \ \\��\VAVAA�/(I lamVv \\ v i V \ V / / / - A \ - -, ����� v v 2.- ----�� �:/ \ - �\ vA\ \VA� - V A FES IN: 534.50 / v / / / / / / / " " v - - v - - - v�\ \ V A APRON @INVERT: v / / / / / \ .\ \ \ \ \ VA \ \ CLASS 1 RIP RAP / v / / I / / A A \ , ORIFICE DIA SKIMMER W/ 1.5 DIA v v v - - - - -� v // v - Y -_ V A - - - v v\ � AAVA \ y v\ \ V A v \ I . \ \ v v / / � � / // / / / / \ \ V ORIFICE v v v v - SFs� � � \ - � � A /' \ - _ - - v v � ��VA / \ v \ \ \ V A / / / / / v �V - v v�vvv�v V A / / / / A - -OUTLET TO CLASS A EC STONE: v v v - - - v - v I ) \ V A \ 8'Lx8'Wx24" THICK' v v _ - r / / / / / V - " . v v - - _ _ - - - \ \ � �540 � � v v v A \ \ \ \ v \ \ / // / / v = 3 X3 X12 DEEP APRON v - - - - \ \ n \ \ \ \ _�� / / //�///� /- �� \� - �� - �� V -- __ \ V ---A --_ V -- V A \ I V \ \ b \ � / v / o - __ V A V v� - w , AA / I I A \ \s \ V A ( -� / / / // // - iv _ - - - - x v - --_- - - V / v v ( / - v�v \�F // / /ii � - v - �� v - - - v v I \ / / / � \ V A 1 I - / r // I - - - - � v� v �°Fs - - v v v I / v �v v M \ \ - \ - - \ \ \ / 5 \ \\ ti1/ ' / IZ- � -� 2.5" DIA SKIMMER W 1.5" DIA � \ \ - - \ \ \ 5k - \ \ N / A V A A \ - 2/ / / / A / / -- v \v v - - - v / / ( \ V A V \, -3 / 5�5 //// i i 'ORIFICE --� v - ----- - v \\v �v vv A \ A A V A VV V ORRO �1 V \ /. / / / V A \ V A / _5 - / y°\ / // ' / / - A I I \ \ _- - \ \ \ SF V \ \ I - V A\ / \ / y / � � i OUTLET TO CLASS A EC STONE: A v - - A v v v v v I \ \ \ / I \ / / / l / l \ \ \ \ '//// // / / 3'X3'X12" DEEP APRON _ - � \ \ \ � \ \ _ - - - - - _ _ - - - \ \ \ \ - SEDIMENT TRAP 6.0 I \ - - \\ / A/ / / / // l / I A V A v\� \ \ \ / �/ ////�// / w vv� ��� A - - - --� v v vvv_DA: 0.28 AC \ \ \ / / / - / / / / / / \ V A v A \ \ _ /// ( - - - v v v \ v - - A - - - - - v v v TOP OF BERM: 539.50 \ \ -� �A VA \ \ V�\ \ / / \ - _ 'v_ v VA o - - - � - - v v v -CREST OF WEIR: 538.00 \ - � / / / \ v� \ - \/s \ \\ zs\ - - - - \ \ \ \ \ / / / /- / // \ /� \\ \\ V A �; ='"� ;� �,�;' \�v \v ' /--,�ww- --- - A vvvv vv LENGTH OF WEIR: 5' w v'-�% - \ / / / �/ / / / / �- \ \ �I A V',° \\ \ '" / / ' i i' �� \ I / / V AA \ \ V � - - - - - A \ V A V A A V - i - - - / / / _ / ;� - - -DA:I EN ACSIN 3 - �w - -- v v - \ \ ° / / v - - v DIMENSIONS ®WEIR:40'Lx20'W \ - v v v v v DEPTH FROM WEIR: 3.5 MIN , v v - / / . / / - \ \ V � / h / - - - - TOP OF BERM• 527.50 I v vvvv v v - A - - v v zs v - - v - v s� - / - -- � \ \ - � - \ \ 3 BAFFLES REQUIRED \`' BRANDYWINE DR / / / / / / / 556 i g V ) / \ \ \ \ I V / _ _ CREST OF WEIR: 526.00 v V \ v � - -� "�' - - - - A - - v v v - v - - - v - v Vv y - - - - - O �o // / / / / \� / / \ I I ( ',� / / \ ' \ \ \ \ \\\ \ - - - \ \ \ - \ \ \ \ - - - - - _ - 'Y / / �' v vLENGTH OF WEIR: 13 v v- - v A v v - v v v - / // / / / / / - V / / / / \ \ V v vv� -- �v v v v v - - v v vA v v vvv - __-- />. i / / / / / / T ;�, I FES: 531.00 DIMENSIONS ®WEIR: 95 Lx47 W \ \ o \\ \� - \ \ \ \ - \ \ - \ - \ \ \ - \ - - F �i � ; _ I _, A \ \ - 1sv vv v - v v v - - - v __ v v - - - S A i / A / - - - - / , APRON @FES: DEPTH FROM WEIR: 2.0 MIN v v v v v v - - A v - v v - - - - 77 - sas- I / / ( 11 i� v \ \ \ - - - _-_ --- ( i / / / / / / / / CLASS 1 RIP RAP: 3 BAFFLES REQUIRED \ \ \ � \ \\ _ � \ \ \ \ - - - \ \ - - - - - _ _ _ _ / / / / / / /� 1 I / I 16'Lx18'Wx24"T \ ` \ V V A � A � \ v v v� v vv \ V v v A - - v v v v A - ��' / \ o / /� - % / - V \ \ \ v A / \ VA \ - - v v - - \ \ \ / // / IT = i // / �� �' \ \ \ \ \� VA \ v v \ ��� V� V� vv---� v v - v v - - - - 2 \ I / // / \ , �j v A \ V A \ \ v A V ( / �"'__ V A \ \ v - - oZs� - v - v v - - - - - - �a�9- O� \ \ \ \ / / / , CULVERT 3.0: //// v /- Fs v \ \ V� \\ \ \ VA \ \ \ \ \ v��A V�v- ����---� v v v v A -_ ---__- p V A / / 91.8 LF 24" RCP / / - � \ \ \ \ \A \ \ VA \ v A \ v v \ VA - ---�v vv - v v --------- ' / / /__� - --_ v -- --_--- / \ / @ 3.81 % SLOPE ( � - \ \ \ \ \ - \ \ \ \ - - sas- _ - - / 1 \ \ V A A / / / / ( - v v A \ \ \ V \ \ \ V A \ \ \ \ �v v v V �� \�- - ���vv v v�----- SITE / / / I A V - i - V A \ \ \ \ \ VA \ \ \ V A \ \ \ \ \ / A \ A - - V A _ A � � - / I. vv v A\ V A\ \� I � I I I / (// / V � vv v � v-__, - v v v v v v v� vv v v vv / v / \ " \ v� v v - -- - A A .9 - A A \ \ �� V A V A V A V ! \ \ - A V V� - - - - �- - - - - - - - -- - - / _ - _sue A \ \ \ \ \ \ BUFFER - - - \ - - - A - _ - - / / V \ I I I I ( ( - �� - - - - - - - \ V A \� \ \ \ \ �\ V A \ V A \ \ I-, A \ \ \ \ STREAM � - ,� �- -�� -- - V-� - _- _ - - - 520- - -- - - - _ ---- _ --_ -_- \`\ \\ �7/ - --'01s -;-- - ---- tip, CALL BEFORE YOU DIG... ITS THE LAW. GRAPHIC SCALE - v I ( \ \ V o / / -- - - - - - - - s`�- _ - _ - _ _5�0 - g141 V I 1 \ J / / / / / / / i - - v _----_- - �� // / / - --- - -- - � �o CALL N.C. ONE-CALL(1-800-632-4949) 60 0 30 60 120 240 \ / / / / / / � / / / / / �// /// / t \ / / _ r. • • _ v sos; - - -_ _ - � - - - - - - � ; ; - A FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST / / / / \ / / / / / / / // / / / \ / _ _ .: _ v - - _ - - � - - = ; 5 � �/- �O 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. ) I / / / i / / / ,�, / / / /� / / // _a;, _ _" __ - - - 5p ___ \ - / / / i i i / / // /�/ iSTREAM v - ____�'- /�004- - - - �_- --���i / /� i » e ( IN FEET) / / !p // i �/� i i --/fy -�- -/ /�/// ///// // � ��/j.< \ __ � , v A- l \ ----_- i %� ��,� 1 =2,000 1 inch = 60 ft. a U 5 g O Hflo - 8 . Q) O C i N W r� L_ (z U Nmm@ uj Co �j L_ Co co a)Co��= � � Cfl O U �(uLnC`7 O Q) N , �-� -, Y U c,Umm Z '- a)) � U mmC a � Cz c CZ i W .. 2 NCO ILL( J I' CM %/ Lu Cm///1, LiuN )Oi'� Z "I- * j. O - Z. V) J Z �' �7 _ a U VO API z Y EL _ 0- � .. 4 (`ool P-4 lIw� �_ � I-4 0 I:� <� = L) 4E4 N L) y) O P4 4 C/D C � Cl) C) 4 P4 0 NL) w w I --I -4 10 -1 � � I --I w M--I mk0 0 0 00 a .md w w w 2 al 2 2 0 z O O OU w 0 Z v E � � O 01: w U �-- w cn �-- 01: cn m 0 O m m w wwoCww 0 D_ oc w IL IL rn rn rn rn o LLI O O O O N O � N N � � 0 o 0 0 0 No LLu r N Co 1� Lo m DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=60' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 WORKING THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. PRELIMINARY SUBDIVISION PLAN P:\17-002\17-002 Drawings\--Working\17-002 Working.dwg, C4.0 - EC Plan, 2/6/2020 8:53:27 AM PROJECT INFORMATION: OWNER/DEVELOPER: ROBERT M. BRAME 2863 SOUTH JIM MINOR RD MEBANE, NC 27302 PROPERTIES INCLUDED IN PROJECT: 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD PIN# 9802-59-3969 PIN# 9802-59-3974 PARCEL ID# 170308 PARCEL ID# 170309 TAX ID# 9-13-183 TAX ID# 9-13-184 2.8 ACRES 3.3 ACRES 2863 JIM MINOR ROAD 2817 JIM MINOR ROAD PIN# 9802-59-5721 PIN# 9802-59-4690 PARCEL ID# 170310 PARCEL ID# 159117 TAX ID# 9-13-185 TAX ID# 9-13-5 1.68 ACRES 14.25 ACRES CULBERSON LN S JIM MINOR ROAD PIN# 9802-58-4657 PIN# 9802-58-9583 PARCEL ID# 159114 PARCEL ID# 159116 TAX ID# 9-13-4A TAX ID# 9-13-4 6.01 ACRES 13.71 ACRES TOWNSHIP 9: THOMPSON DEED/PLAT REFERENCES: DB: 2823 PG: 0093 PB: 073 PG: 0293 DB: 3239 PG: 0957 DB: 2487 PG: 215 PB: 073 PG: 0293 SOILS: CnB2, CnC2, CnD2, CnE2 = CULLEN CLAY LOAM = GROUP C RvA = RIVERVIEW LOAM = HYDROLOGIC GROUP B WtB = WYNOTT-ENON COMPLEX = HYDROLOGIC GROUP C FEMA MAP #3710980200 K, EFFECTIVE 11/17/2017 FLOOD HAZARDS PRESENT TOTAL ACREAGE: 41.74 ACRES BY SURVEY TOTAL # PROPOSED LOTS: 33 LOTS AVERAGE LOT SIZE: 0.49 ACRES (NOT INCLUDING LOT #33) TOTAL OPEN SPACE: 530,223 SF OR 12.17 ACRES WINDING CREEK TRAIL: 316.09 LF FOREST CREEK LANE: 1,186.86 LF NAK(;LL IU#J I /U,)Ub, I /U,)U'J, I /U,) I U, I n&1 14, 1 ny I I b, 15y I I / / / / / I i / / / / \ / / � ` VX 1 /% - \ - - - - -_ � - A \� - V� \� - - / / / / / j _ II I /� ��� � DAMM135SACMENT BASIN 1. - - - �s - - -_ �-_ �- �`zs \ v� - - -- s-- - CULVERT �. (� ���-���-�A \VA V ��- � w'- / / / / / / // / V \I II I / u � - -A - 33.4 LF 15" RCP ��\\ FES OUT: 532.00 �� - _ � / / - / / / i � -� -TOP OF BERM: 549.50 � - -� @ 1.50% SLOPE � __ � �� � v v APRON @ FES: w v_ / ) 1 I \ / / .CREST OF WEIR: 548.00 - -� - -- ; �� - i_ - - � - �� �v CLASS A EC STONE: vv �� / / / / / - \ - �/ / / / l / / / i +* DITCH: � i /�v \ - ----,�-�i/� -� �� � � �\ - / / / ( p / \ I / / / / v LENGTH OF WEIR: 5 _ - --� - . v v 5'Lx6.25'Wx12"T / v _ / _ /�� - -�� ROCK PIPE INLET \ V - V / / / / / ( ) 1 I I / / / - - ---- �1v v I A s s' / / - � i / DIMENSIONS ® WEIR: 52 Lx26 W - - -\ - A v V /� / / / - ) / �/ - - \ - /� / DEPTH F S WWII RED. ��-- - - PROTECTION \ �� v VA \� \ \ - -_ 9 O / TERMINATION POINT OF EXISTING 8" / / / / / / I , / \ \ \ \ n / - / - - �- - /�' - -- - V \ VA% /'ORANGE-ALAMANCE PUBLIC WATER MAIN (PER ( % p���, E / / / % �) \ ( ass _ \� 1_ - - V � � C�� �\ VA /� O mfl ORANGE-ALAMANCE). FIELD VERIFY PRIOR ( i / ( ��� 9 f / ( %\ \ \ C - - \ � �\ \ 9 / TO START OF CONSTRUCTION. \V ��� I `y Gu yG / /// / /) \V - PROPOSED V' ��' . �I/ � � - �F _i ....: ; / ( FG� ��� Oy�OZ O , - - DITCH: SOUTH 3 - - - - - - / �/ /� / \ " " - - - A EASEMENT v V A !� h \ DITCH: ��� , A \ i / / / A \ 3 DIA SKIMMER W 0.75 DIA - - - v - V A �� P ^% - / / �� i ORIFICE A I 0 O \ O - O - DA• 0.79+0.09+0.06+0.11 AC , / / / / \ \ �' DA: 0.06 AC \ \ V v �� o R� \ \ / LINER: JUTE NET - / / �� / A / \ \ \ N TEMP LINER: \ V - Q) �� OUTLET TO CLASS A EC STONE: - i� �x � � \ \ � U \ I� / - - - ,\ \ \ \ - -_ _ - 5� - - / � v " - � FES IN: 532.50v A STRAW W�NET \ � L_� i \ - 3 X3 X12 DEEP APRON / ` - - A • �I / �E \ - _ - / / � = _ = � / +��� v v APRON @ FES: �' �� A V V . V - C / � � --� \ \ � �- -- _ --- //- _ �/� v v_--A v � / \\V A \ \ \ \ VA� _ - CLASS A EC STONE: \ \ \ \ \ \ \ \ N \ �� �� i ___ \� ---- _- _--_ i�-- / - /-- \ V l V�. \ \\�\ \ \ \ �` - ,> \ \ \ ��� -----;- - --------� �/ _- / v , V 3.75'Lx3.75'Wx12"T o V � U ��, / \ \ \ - A \���--- - - - -stis, -)/1// �_e - - v �� v v v V �/� / V A A\ \ \ VA \\ \\ \ \ �\ I I I 4- - / " -- �E� \ \ \ --- -�-� -----� � / // / �/ / --/ - "" \ -, - �V A - ' \ \ \ \ \ \V A\ �'\\V A \ \\ I I W � C� CZ �� * / _� - - _ CULVERT 1.1: - i 1 A / // =� - v v / \ � A \ V SILT FENCE O N " - - - - DRIVE PIPE - /, ^ / / j -� / / / � � �� A - L - A \ v \ OUTLET 0 N @ \ - i - - - - - v\ -- __ - DITCH: 2.1 m \ \ '11 I,-- ,�- a- �_, �� i < / /--�/- v / \\�\\ \\�\ L_ N O - 45.5 LF 15" RCP - � A v o A � - A s r (TYPICAL) Co A � I I I / h � v '_1' s - .1 , / � � - __ @ 0.57% SLOPE ,- - - / �/ / �i a - -- - DA: AC �,� \ \\ +� C`7 C`7 � / )5P, h \ F - - - - - � v �vA \ TEMP LINER: x A \ \ r, Cfl O U / v N I-, / / 12'X50' CONSTRUCTION ENTRANCE �/ , - ���� - - SEDIMENT TRAP 1.2 \\ \� \ \ V A \� \ V A A � N W N O - __ \ \ - � DA: 0.39 AC CURLEX II OR \ 20\0 / I - 1 _ / -� -� ( - - - - vsus - - - \ - TOP OF BERM: 530.50 EQUIVALENT \ \ \\ \ \ \ V A \ \ v A A\ > U m m _- \ � � / / FES IN: 548.36 i -v / / � � - - v A � -_ � - - \ � �\ �-) - �� 1 - v v - -CREST OF WEIR: 529.00 \Z r r , / / APRON @ FES: � / i �, �� � / - v \ - _ ( \ A )� \ V A A , A k1 � O� / \ CLASS A EC STONE: j / - - - V A \ N / v / / V � LENGTH OF WEIR• 5 / 1� 1 II \ \ \ \ / - - - - DIMENSIONS ®WEIR: 34 Lx17 W / \ \ \ \ \ N _ / ) I 3.75'Lx3.75'Wx12"T i V �� FES OUT: 548.10 , i / - - - v V ) \ � V \ \ L U N i i L APRON @FES: - v \ v / - V - - - - - ,DEPTH FROM WEIR: 3.5 MIN - / / / A I \ \ V A \ \ , L N M C: (is J ,. /� lei CLASS A EC STONE: A V \ SEDIMENT TRAP 1.0 � - - YARD INLET 1.0: 3 BAFFLES REQUIRED _ �/ �� 5� �� A DA: 0.25 AC - - - - _-_ WEIRS: 526.90 - � -os^- C01 WATTLE ATTLE / / / /� I I� I,�\ \ \ \ VA V V V 6 O = � � / / V 15'Lx6.25'Wx12' T \ \ \ - - / \ �' \ / � ��C INV OUT: 523.50 �A - _ OR CHECK DAM / I V J N LL W ROCK PIPE INLET �. - v TOP OF BERM: 530.50 - _ V - - / \ \ \ \ \ / PROTECTION / i / yso 1 v - - - v v CREST OF WEIR: 529.00 - � - - A V v - - - - A / / i (TYPICAL) / v DITCH: SOUTH 2 / / / % \ �s v - � v - v v LENGTH OF WEIR: 5' � � - - - v v � � - � - / l� �J \ \ \ \, 0- � / DA:0.79 AC / /i ; - v � \ \� DIMENSIONS ®WEIR:34'Lx1TW / V - v\ v DITCH: 1.2 � - - - - - - - - / , I \ \ \ \ I � / � \ - - - \ \ \ DA: 0.38 AC- sys, / , c+) / TEMP. LINER: - - / / (j / „+ tT \� � - \ DEPTH FROM WEIR: 3.5' MIN / � \ - j - \\ \ \ \ TEMP LINER: - - / I \ \ I I I \ \�� a uun1pu#/�/�i�i�i/ W N \ \ / / JUTE NET - - 3 BAFFLES REQUIRED \ \ \ - _ cm / - AREA OF DISTURBANCE _ i) < /j - DIT:;H: DRIVE 1.0 - �\ - \ \ \ / / - \� \ \ JUTE NET - - - - - - / / \ \ I 1 I r �* 295,504 SF OR 6.78 AC / DA: 0.09 AC /���� s� , A \ \ \ \ I / II l / / / _ : v � __ - - - - / 1 1 I �� • . u Z t1� \ �/ / `' TEMP LINER. �_/ �i \ ) \ l I I / / � I / / _ -_-, ;:.� =-- --_ ----- -- / �// / / •� J ---CL y PATTON MILL LANE (PRIVATE): 1,271.77 LF 1 STRAW W�NET \� \ / M 1 ! �: , - - - - - _ DITCH: NORTH 2 i �s V l I h J os- - - - - - � / 7- fl' DA: 0.34 AC / °� 1` /. � / - y I I I J 1 ( / ' - - �srs °�s` / / / / _ z ; N _ _j Z I TEMP LINER: JUTE NET � / i �� v , s ( -�--------- _ - � - / / / U' \ I I I )� \ V I --- , («oz) se aver-aivo am - �)\ - - \ / , / _ - - o / _ _ G-� 1 •' \ / / ,, / I / �' __ - v � � � �' yL I \ V � I � \ \ \ \ ram= „y �_ �� � _ �� - _ / / / � %, .•�Q- U O i - - - i i / / / i/// • ' ������� Z Y � � � I ( \ \ / I/ / i o ( \x // v \ �_ I/ __ - v , / , A \ - v � V - - - _ - moo - / / / � / i an i uaa��� - \ \� _ 1 -- - - - - _ _ \ v - A V A A\ \ 12'X50' CONSTRUCTION ENTRANCE / �� \ / ) A A V A� �A A _o� �� /� - - - - - - - - - - - / ' �� %/� .. v \ v \ V \ / v / ) \ `o A v s sas - - - / i \� , I\ \ v \ \ V A \ S9 / / �� - A AV -- 1s \ A 7 �� - � - --� - - - -� � '- - , 9k. �/jj:��� \ \ \ \ \ \ \ � / / I i i / \ � \ \ \ � DITCH: 1.1 \ \ �, --_ RT 1 0 - - - - - -- - - - - - - V A \ b9s \ \ V A A \ � / /�- / / \ - \ \ v \ V DA: 0.18 AC = - - _ , �s ������� - - - - SEDIMENT TRAP 1.3 - - _ _ _ _ _ - - - V A v A V A \ / " v V V A \ V I � �0, - _ -- - - _ ------ � _- ��- - I I CULVE V A V \ i i/ A v TEMP LINER: j �„ I / - A 71.9 LF 24" RCP - DA: 0.28 AC - - � �/I ® M v V A V A A \ v v A, oo , �/ - \ V CURLEX II OR v - / - \ v A �`� ' _ - - ;III - @ 2.09% SLOPE , - STOP OF BERM: 524.50 -sas- - %�oj� ii�; DITCH: NORTH 1 \ \ \ - / DITCH: 5.1 V A \ \ EQUIVALENT \ 1 _ I _ - - - - - - - - - - - ��- "/ /, `� CREST OF WEIR: 523.00 k� � �_ - _- -------- / ii �i // \ -� ,---__-- // , i / DA: 1.03 AC A A V A v ✓ ;A� . DA:0.19 AC �s v A A \ \ \ \ s \ \ � �� \ SEDIMENT TRAP 1.0 I \ T T � � � - III - - - - -LENGTH OF WEIR: 5' _ �� � ���j v 1 FES IN: 538.50 \ \ \ _ _ - - DIMENSIONS ® WEIR:35 Lx17 W _ - ____- - %� /,/ // TEMP LINER: � V A \ �' � � - , % � i TEMP. LINER: V A v DA: 0.34 AC V A 1 I I I � \ - ii /�i/ /� / �� � M-� STRAW W ET \ V A \ \ I - _/ - / .: � STRAW W�NET APRON @ FES: \ � A v A v A \ \ \ \ \ \ i - CLASS A EC STONE. I \ \ \ - - - - - - � DEPTH FROM WEIR: 3.5 MIN - - - - / / /ij // \ ,\ V \ V A \ v - - - - - - � - - A A / / CREST T OF 524.00 FES APRON @ FES: \ \VA V 1 I -ors - - /i,%, /�/ DITCH: 5.2 i \ � - - - _ - - - - - � /�5 / / / / O \ _ _ _ _ --- 3 BAFFLES REQUIRED _ �i� i// Z ��// / \ 4.5'Lx4.5'Wx12"T DA.0.31 AC CLASS 1 RIP RAP: \ - i / // \ \ \ " \ � \ / LENGTH OF WEIR: 5 \ \ \ \ 1 ` \ V V A \ / / \ TEMP LINER: \ / / V A A \ \ \ V A \ V �� \ - - _ - - - - - - -, � / /� / // A V \ \ - % �� / V \ CULVERT 5.0: A / / / DIMENSIONS ® \ V 16'Lx18'Wx24"T \ \ V C - _ - ��� - - __ � _-i //j �% / /, 11 / STRAW W�NET o \ v ` V A \ - _ - � �� � _ i - _ /i� / / �,o/// �,�j I --I \ \ V A V A A V A / - - - A / WEIR: 40 Lx20 W 800 SF v \ \ \ V A \ \ \ \ \ \ - - \ - � ; - _� \ \ V A COIR WATTLE - /�- / \_ 54.7 LF 18" RCP \ i \ s, / \ \ \ \ \ \ \ \ \ \ - _ V A 1 V A OR CHECK DAM - , � / , I �k o `�, / / - @ 1.01 % SLOPE _ - - \ \ \ / / / // / DEPTH FROM WEIR: 3.5 MIN, \ \\ \ \\ \ \ VA V A \ VA AA \ V�\ \ V� �� A� y -- - - �i /- - j j/ ii / j � /// \ \ \ TYPICAL / / °a / - - - - - \�_ - - �_ / / 3 BAFFLES REQUIRED \ \ A\ \ \ \ \ SOS �A i i ��/ / / / // / ( )_� \ \ V \\ VA \ \ \ A V A\ \\ \ \ VA �\ �� - - - \ - A v / / / / A A - - - 5� - i � / / // /j / I - - A s \\ \ s �,� v v / / / \ V A\ \\\ s \ \ s \ -��� -�_- � ��- � / -v/- //// -� � / I \\ \ \ \ \ \ \ --- �� __- / / \ \ - �� - // \ \I \ \ \ \ �\ \\ \ \ \\ \\\ __�- � __ / //// �/� 0 - TEMP LINER. ` / A \ / I 1 A v �.%�, _ 5 \ \\ V A �\ \ \ \\\ \� _ _ _ v // vj I v /- v vv v v v vvvv v --- i/ E-, \ \ STRAW W NET / `:� - - \ \ \ \ \ - - - - - _ - �/ - / / / ' �i- � -� / / / l I \\\� V Ab\ V A\ V A \ \ -- -�/ice -i/ _�_ � \ I V - A�Bk e - �� - / / I \ \ V A \ \ \ \ \ \ \ \ \ - ��� - - - I I / - / V � I I I \ \ ,6 \ \ A - -S � / / �� \ \\ / A \ �V - , v \- - / / / / I \ \ \ \ V 1 \ V A \ \ - - - +j- - I tiG� \ \ - \ ) �� - / - - I �/ v - - _ i / l 111 �111v1�V v�� ,� �, / / / / E-� U) tiI 1 ) I \ o --- - \ / i / I II I I II It 1 - ,j & / I v / I _ - - � v / 1� I \�� „� - � / O \ / I �' /- - - ��� v ` / DITCH. 6.1 / I a I I 1 I SEDIMENT TRAP 6.1 V 1 I 1 I 1 I � V'495-- �_ - � / // / ( /-' V- v / / I I DA: 0.50 AC N / I 1 1 TOP OF BERM: 534.50 1 I N--I / / ) ROCK PIPE INLET o - i\ - A _ V v� _ / DA: 0.24 AC / / \ - / + / X - PROTECTION . A ° I` - �� ° TEMP LINER: ( / / / / / 1 1 I I I CREST OF WEIR: 533.00 I I - - - � / / - /• 0 / ) LENGTH OF WEIR: 5 1 1 . • I- �� / / A \ - A \\ o A / / I� I / u W n� �� V - A ��s \ V A ss \, / STRAW WNET / / I I I A // / /� xo \ - v A �� l �I \ V I / / / , I I FES IN: 537.00 ) o VE _ � v \ �\ v '- ' / I I DIMENSIONS ®WEIR:44 Lx21 W I 1 J + � � /\ . /. +� DITCH: SOUTH 1 - - - / / ,� __ A v v v - _ 1 / \ W / / j � � I I ( APRON @FES: /� %, 5 -_ _,;; FES OUT: 537.95 � \ v v� / / � I I 1 I I DEPTH FROM WEIR: 3.5 MIN � I � I \� I I ) � � / �/ DA: 3.56 AC / I CLASS B EC STONE:, I APRON @ FES: - / ( I / I � / j � , � � - \ � v \� , - � I COIR WATTLE I I I I I J 13 BAFFLES REQUIRED I 1 I I a� •/ TEMP LINER: , 6'Lx6'Wx18' T 1, CL�aSS A EC STONE: _ wry. � / I I OR CHECK DAM I � I I I I I , I I 1 t I I y / �/ �j / // G � CURLEX II 555 �- / I I v / \ - - I I � I + T / I �/ / / / I I ' 7.5'Wx12' T DITCH: - �s� TYPICAL I �-I oF� - - v v -� v V �l / � SEDIMENT is+33eo �� i l l � � \ I I I E - v I I FENCE I� - ��� � \ TEMP. LINER: -� o� / / / / - v I I l \ \\\I \\ \ 1 zI I I I I � I /�, / � / � / ( ti�F 9j, / / - - I I i w ;l II - - _ � STRAW W�NET v / � V o ( /`� /' � '9� G cP ti CULVERT 4.0: / \ \ \ \ \ v ��\�\ I / /�'L'L n / / / / A °fo s,� \ V A � / / Q0/ o / / --A �� \Vv As v vvv v s \ VAs \\ \ sVA4 7\ R�G�%�F ����� ..: / / / - - - i ) 51.9 LF 24" RCP 1; :! - ��\ v \V A v -v - - I - OUTLET:A \ o \ \c O,F - - V �" __ �� v - ��� ,,, ��� V A DA:a12 Ac �vv vvs v � I ��� ►-i G / / i J @ 1.93% SLOPE I I I/ \ \ \ \ \ \ \ \ O E F O / / i �1, I \ \\ \\ o �� \ �P \ yO.� / / / / DITCH: 3.0 - - - � � i� l � A v \ / ��;�,, \ V A \ \ \ \ I J 0 0��� \ V I / / / / DA:0.33 AC m A FES OUT.536.00 v - v V A \ / ��-, %` ` A \ �\ \VA\VA \ \\ \ V A \ A \ / � • W - -''i v - v \ V A\ \ \ V \ \ v V A I. / / - - o TEMP LINER: / / / APRON @FES: v � � v A A / o \ V A \ \ \VA VA \ �\\ VA V A t \ I I / / �.- \ \ - 55 / CLASS B EC STONE: v v V A V DITCH: 6.2 , / r \ \ \ \ . \ V \ \ \ � \ I / / ---- JUTE NET I I / �� A V A\ \ \ 4,, v v A\ \\ \ / . - - A v v DA: 0.26 AC / v \ VAA\ \ V\ \ , vA , A \ \ \ I � ( � �,* \ \ \ \ \ I / / / � / ' I I / / 12'Lx14'Wx18"T � \ \ \ \ \ i � \ \ \ \ \ I I / \ \ / / ( _ - _ _ I� / (/ - -_ - v A \ STRAW W�NET \ V A VAA\ \\ v� v` STREAM /� VAA V�I I I I / � - �(.>_ IL IL 0L IL EL \ \ \ V ( I \ ( / / / / ( I I ,. / / / / v \ \ TEMP. LINER: / v \ \ \ , A \ \\ \ / V \ / % \ \ y VA V A \ VA\ \ \ V A \ V A \ \ / � /SEDIMENT BASIN 4 5: v v � / A v \ v V v v V v\ \ <I I /m U U C) U U \ sus \ V A \ \ / - / i � - I I / _ - v v A \ _ � �� \ �iA A \ �,s \ \ V\ � \ \v vv v BUFFER \\ \\ \ I I / \ A V A v . V I I / - J / I I til I V DA: 6.42 AC v v V A\ V A SEDIMENT - A �, \ v \ \VA \ _ _ � vvA A \\ V\� \I 1VI / / TOP OF BERM: 536.50 � - v A \ � A\ \ \ \ / - \ V \ V A \ I V � / - - I i � � I I � � V � V A V A - FENCE - � �� V \ \ �� � � �� v � \ � A � � , ) � \ \ \ V A \ \ \ v \ \ \ \ \ ( � - I I ) M / / �� A \ V CREST OF WEIR: 535.00 �_, v V A A - . - --- V A \ \ \ - -� �\ � �, A� A \ VA \V A\ \ 50 0 V A v A V A A V A t V A A V l / - COIR WATTLE I J /) J) I I v hti V A \ v LENGTH OF WEIR: 12 �\ V v V A \ _ --- 7 v\ _- �� A \\ \V\\ (� V A / A'\ 0 \ \ V \ \ \ V � - „� T, iA A V A \V % ) \ \ V A * V A A \ \ \ I ROCK PIPE INLET � OR CHECK DAM I / / ( SEDIMENT \ \ �', DIMENSIONS ® WEIR:95 Lx45 W v v v - robs , - - . /,� \ �A v \ \\ \ \\ // ��C V A \ u� u� z \ Lu v \ \ v � * v y \ ss \ \ \ PROTECTION - TYPICAL), / /V \ \ - - - - - v vVA \\ V \ \ (, v v� - - -_ - Z O z 2 1 V A A V 9 v V O V A V A / / \ ( I I I / FENCE \ V DEPTH FROM WEIR: 2.0 MIN \ \ v v \ \ \ z 0� \ 1 / � / \ \ \ \ \ " / / / I / / / / A \ 3 BAFFLES REQUIRED _ � � A - - - (, \ \ \ - - - v \V A A \\ /i ����� v \\\V / � / w o= w \ \ A I / - - __ / / / - - - - � � VA \ \ \ / \ y A \\\ VAVAA V A - ��-/� / /, // / A \ _2.5 DIA IMMER W� .5 DIA v vvv ----- -� -�� // v V A--- -� - v\ VAS ��0�y \ ���\\\� A y. �_ 2 z __ C) \ \ \ FES IN: 534.50 / / /, � / / / / ' - " " � \ � � \ � v� A / \ V \ \ V \ / / / / / / r \ \ ORIFICE v s _ -- - O_ O O 1 \ \ \ \ CLASOS 1@RIPVRAP - / v - A - A - - - - __ U z O� U w \ \ \ \ \ \ \ \ � / / / / / \ \\ - - OUTLET TO CLASS A EC STONE: - \ - Fs - \ - - ( 1 V A V \ 8'Lx8'Wx24" THICK' / - / / /�j / / / v V - - " . � v __ - - - - - - A \ SEDIMENT I - - U C3 Z U / / \ \ \ \ V A V A v v \ � - !_ - / / / / / / // / / / v 3 X3 X12 DEEP APRON � � - - - - - - v A FENCE - - , oC m � O m w ( / A \ \ A VA VA b�\ \ VA / \ �� �/ / ° / / / /,%//�/ // /cr \� - \, __ v �� -- --- / \ \ \s \ V A \ �'� / / \ - - \v - ----- - \ \ DITCH: 6.3 - / -� w w mw oOc w w ✓/ // / g2 �v - v / \ \ \ \ \ / �__ / - s - DA: 0.19 AC V 1 � \ V A \ - / �/ / / i � v - __ A\ \ , v _ v TEMP LINER: / \ \ - � - - FIBERGLASS � / n"5- N �& rn rn rn rn o \ ]/{// / \ \ I - �� �� � // � 2.5 DIA SKIMMER W 1.5 DIA � V\ v v �°�'s - v \ � I ( / � - v � o m m w m m I J \ V A \ �/� Z// / / //// / V\V - \ \ / I / ( \ \ \ - �s / h / / /// V v v - - - - - v v \ v SINGLE ROVING � I A \ ( M V A 1 V A V - / y� / / i "ORIFICE - - V Av - - - v � M/ c� / \ / _ / o %/// / \ - - v v � v \ N w o00 % ) / \ V / \ �/ 5 - 5� / i OUTLET TO CLASS A EC STONE: - \ v - - v v v v � , � A V OR R N N N N N / / / � / / \ / / // / / / � 3-X3'X12" DEEP_ APRON - V A (< < - - - - - - v D 5N 5N v v ' SEDIMENT TRAP 6.0 _ _ / / / / / / / / ) / / 1 A V A V A\ / / // /////�/// i, - -� -�, -� A�\\- - v v v \ \ �� o 0 0 0 o c� / / / / \ \ \�/// ( -- � vvvv vv- A v v v \ r o / / / / . ( . / / / \ V A \ VA _ / V / - - - \ \ / - - - - - v v A TOP OF BERM: 539.50 / \V\ \ / / --\v �vA � A / / / I -__ / / l I \ V i ,, \ V A - - - �.�.v\V , - - __,-- - \ v v\ v\ w c� C0 � Lo / / / A A V A ( � - - - vv v v v 'CREST OF WEIR: 538.00 \ / % � / // I \ V - A \ , \ \ v \� - - LENGTH OF WEIR: 5 \ v v m / / / / / A \ / {��{ - - V - A A � \V - - A \ - / 0� - / / / / �- ___ / \ �, - SEDIMENT BASIN 3 I - \� - - - - V A �A - DATE: AUGUST 29, 2018 DIMENSIONS ®WEIR:40 Lx20 W / i / / / / \ \ \ j / /,,; - DA: 6.62 AC / - � � - - - - v A � DEPTH FROM WEIR: 3.5 MIN , � - / / / / 5 � / - - ) V A \ \< V / / - V V A - ��-_ �� - - - - v v v '_1 - - - -_ ' 3 BAFFLES REQUIRED - u�s_HORIZONTAL SCALE: r�-6o' � / / � / / - -- A \ h „��'--� - - -TOP OF BERM: 527.50 I / 5 / � - \ \ - - VERTICAL SCALE: N/A / / �� / 5 - - / �` \ / / ij / / �� - - - CREST OF WEIR: 526� 00 V ��� - - - v v v - - - - - BRANDYWINE DR / / / \ \ ;; A \ �A� - - / , / \\ ; '' -� LENGTH OF WEIR: 13 ���� A \ - - - PROJECT MANAGER: CPK / / / / / / - - / A / / / I I '�;I. I / FES: 531.00 DIMENSIONS ®WEIR: 95'Lx4TW \ \ \ \ �� _ - \ v v v - - _ - �� �� - �� DRAWN BY: CPK / - - - - _-_ _, - APRON @ FES: DEPTH FROM WEIR: 2.0 MIN \ v - - - PROJECT NO: n-oo2 / / ) / / / / l/ v \ V - �� vv v\ � --- - - � - - - �F` / / CLASS 1 RIP RAP: 3 BAFFLES REQUIRED \ \ \ - \ - - - - - - Q J� A DRAWING NAME: 17-002 WORKING / / / �/ - V V A \ - / \ I / / / - _ / / / l� I) I � --- 16'Lx18'Wx24"T v v v \ v v v � v v A / v v v v v \ - - F I V 0 / -' / / / \ i A \ V A \ \ VA \ V\ \ V A A _ � __ O - A - _ - �V Q THIS DRAWING AND THE DESIGN HEREON ARE / �� CULVERT 3,0; / / / bF-�, \ \ V A V A V A / \ \ V A V A _ - (�� 'lam THE PROPERTY OF EarthCentric Engineering, Inc. \ \ \ 1 I \ \ / / / / / ) - - A , \ \ \ VA V A \ \ \ \ \ � I I \ �\ A A V\ - - - - - - 2 THE INFORMATION ON THIS DRAWING IS NOT FOR \ / / / 91 .8 LF 24" RCP / / \ \ \ \ \ A \ \ VA \ \ \ \ V A - - - - - \ \ � - - - - O USE ON ANY OTHER SITE OR PROJECT. THE / \ I J I / � i - - - __ A A \ \ V A - - A \ - - V \ V I I / / / @ 3.81 % SLOPE ( ) , , - V � A \ \ VA V A \ \ VA V A A \ \ \ \ \ �` \�� - - A - - _ - 4Z4- -- Q REPRODUCTION OR OTHER USE OF THIS / / I 1 \ \ / ( - - - - - - \ A V '\ \ A V A �� - - \ \ � - - - - - - _ - - - - DRAWING IN WHOLE OR IN PART, WITHOUT \ \ A V A I / / / I ( 1 / V A - i - - V A A \ \ \ \ \ \ \ \ \ \ V \ \ \ \ \ / A - - A A \ - - - - - - _ - - _ (�Q' WRITTEN CONSENT OF EarthCentric Engineering, Inc., / / ) I V A \ I I I �/ / � A A \ - \ - i - - V A \ \ \ V A\ VA V \ t / V A - - - - - - A / / / .� ) A A I ( A V - _ -- sp � _ - - V A \ \\ \ \ V A s� V A \ \� \ \ V v V A \� STREA BUFFER - - - �� - - - -�-� V- - A SITE �� IS PROHIBITED. �� - - - -- - - - - - - 520 COPYRIGHT 2020 EarthCentric Engineering, Inc. v - �� ���- _ --- � A V A \ \ \ \ \ �� V A V A \ \\ \ \\\\ M.�. _- '� __ -_ �- - - � - / // /v �//-j / ) I I I A ) I I v v-- _ --ok Z vv \\ V A \ � \ \ \ \ \ \ \ \ v / > > / / > >.j /�7 / _ --� � -- - - / / / � / I l / ) I I I 1 / - - -- - -� � --- -v � \ \I \1 \ \ \ \ V \ \ \ I ( / / /� //, / / / / - ���,� �� �� -- ----- c %p - - s' - SHEET NO. tiH, \ - - v \ \ \ / / �/ / a/ / / / / - - - - ----- ---__- '� CALL BEFORE YOU DIG... IT'S THE LAW. GRAPHIC SCALE v \I ) � I I // / / / / / I / / // / / j/� �,n / / ( _ I _ / r � sos_ - � � _ Ys.9 _ - - - �. - CALL N.C. ONE -CALL 1-800-632-4949 60 0 30 60 120 240 / / / / / / / / / / _ ,/ / / /,� // / /x// / �J- -+ -�- • _'' _ � - - _ - - - - - - _ , -� �'A FOR LOCATION OF UNDERGROUND UTILITIES AT LEASTC40 I ) ) / z/ / / /z / / / / / /�/ \ / /// /lz/ / i �� �" STREAM v - - - �- - - - - - �i p 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. / / / / __ � / / - - - , NORTH CAROLINA GENERAL STATUTE 87-102 / / y� / / / / / / / / / / / // /�// / / �/ A _ - - / / � _ -- - - - - �- VICINITY MAP �%pwi ��( IN FEET ) / / // j // �� / / / / / / - - / /�i L0 / // // / / .��"_ �- � � _- - - - � � - - - - - \ \ _� �i / /� I»=`2�000s / /-// / , / I/ -_ _ ��� i /5//� / // / -- - - �- i i 1 inch = 60 ft. � C �'� - - __ - - . A \ - - - - PRELIMINARY SUBDIVISION PLAN P:\17-002\17-002 Drawings\--Working\17-002 Working.dwg, C4.1 - EC Plan (2), 2/6/2020 8:53:31 AM NAK(;LL IU#J I /U,)Ub, I /U,)U'J, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I / N PROJECT INFORMATION: TOWNSHIP 9: THOMPSON - / �' �/� _ - - V- - �� - �1 , \�- - - V V� �`� _ - DEED�PLAT REFERENCES: - - \- 7 - - - CULVERT C �\ �� VA V ��� - - - - \ I \ I \ I /,7���, � - V � V A - - �- -A- - - - S£S - - - -ASZ \ VA� \ - i / / \ \ � - - �� �A 33.4 LF 15" RCP -_� �\\ FES OUT: 532.00 " - - - OWNER DEVELOPER: DB: 2823 PG: 0093 PB: 073 PG: 0293 i \ \ u/ / -�� �� �� - - -��s - _ �� @ 1.50% SLOPE �� �� APRON @FES: �� �� - - DB: 3239 PG: 0957 i , -- -\ _/ ( \ A A \ i / /j j - - - - _ � �-, / � � � � � �� - ROBERT M. BRAME i � / � A - _ -- - 77 �// - - - _ \ - CLASS A EC STONE: \ _ - - 2863 SOUTH JIM MINOR RD DB: 2487 PG: 215 PB: 073 PG: 0293 \ / / - - - - - - / - \ - - - MEBANE, NC 27302 5S5/ / - - - / \ �� // %�� 1-1 - - -�-� �� ���� �� �� A� �V� � �� \ 5'Lx6 25'Wx12"T VAX " t SOILS: i i _ - A - / h %__ - - - - - - - - �- �� -�.% 1 I V �� �� VA\\AA VA V AAA `- �- CnB2, CnC2, CnD2, CnE2 = CULLEN CLAY LOAM = GROUP C / / ) ) / / / - � - - - - � - - - �7 A \ \% - PROPERTIES INCLUDED IN PROJECT: i - 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD RvA = RIVERVIEW LOAM = HYDROLOGIC GROUP B / - _ - / / / % y V / - - - - - - - - - - -- - -A- � v �� � �\ VA A�� - WtB = WYNOTT-ENON COMPLEX =HYDROLOGIC GROUP C i / - ( / - - - - - - - - - - -- -g�L_1 j�\ \ V v s �- lbM3A18a �L\ 1 PIN 9802-59-3969 PIN 9802-59-3974 / / /- - - - - PARCEL ID# 170308 PARCEL ID# 170309 � - - - - - - - / // / / ) / / , \ / - - _ - - - __-99 - - _ _ _ �V/� VA V \ \ �\ �_, __ y - \ _ TAX ID# 9-13-183 TAX ID# 9-13-184 FEMA MAP #3710980200 K, EFFECTIVE 11/17/2017 �' - / / / / A � - - - - -- - - �A A \\ V V A �� �', - -- - _ � � � V A \ \��- - - -:�--- -moo FLOOD HAZARDS PRESENT � / / / - - - - - A A - Z 2.8 ACRES 3.3 ACRES -_ ---- /// / / / \ /----_--- --A �� \\ \V\ V� 0 \ -s - 2863 JIM MINOR ROAD 2817 JIM MINOR ROAD TOTAL ACREAGE: 41.74 ACRES BY SURVEY - - - / _ - � / / // /�� / / / \ \ / �_ - - - - � j A\A \ V A I V A \ \+ + \ + --- TOTAL \ PINS( 9802-59-5721 PINS( 9802-59-4690 # PROPOSED LOTS: 33 LOTS / / / / �,� / ( \ V i A \ \ \ N ( \ + +\ + + + if # - - - /� I \ - / �. \ \ \ n- \ N \ \ \ PARCEL ID# 170310 PARCEL ID# 159117 AVERAGE LOT SIZE: 0.49 ACRES (NOT INCLUDING LOT #33) o - - - / / - � v V \ + \+ \+� � \ + �+ +\ +� / - _ A \ A � \ / FES IN: @FES: \ \ V A TAX ID# 9-13-185 TAX ID# 9-13-5 TOTAL OPEN SPACE: 530,223 SF OR 12.17 ACRES - � 5� - _ � / � ���\ � � v � APRON @FES: V ° +�\+ � � \ \+V A+ � + + 1.68 ACRES 14.25 ACRES WINDING CREEK TRAIL: 316.09 LF - - - / // - - - �� �+/ � \ -A A \ -,,�,, / Z � CLASS A EC STONE: A \ \ \ � \ \ \+\ + \ \+ I+ + I FOREST CREEK LANE: 1,186.86 LF - - - - ,� �j -- - / / � - � \ \ \ A \/ /- \ 3.75'Lx3.75'Wx12"T \ V A \+\+ + \+ +\ +V A+ + �+ +I+ CULBERSON LN S JIM MINOR ROAD PATTON MILL LANE (PRIVATE): 1,271.77 LF - - _ - i - i A � / v __ - 1 � A \ / A \ \ + \+ \+\ + ��/ / 1 --- �� v V v / \ \ \ �A �+ +�\+ +� �+ + �+ v v � PIN# 9802-58-4657 PIN# 9802-58-9583 _\ - - - - - / / -_7 \ -� / / � \ - � \ \ � / \ \ \ \ + + + + PARCEL ID# 159114 PARCEL ID# 159116 _ A _ - - /� - / A - A TAX ID# 9-13-4A TAX ID# 9-13-4 - - - - - - - CULVERT 1.1: - - - - � 1 A j //�\ �\ - - �\/ \ '�� - ��� ��V � /� \ \ V A \ \ \ V �� A \ \+ �+� +� +� 4 � 41 6.01 ACRES 13.71 ACRES - � DRIVE PIPE -- - � / / / _ � � � \ \ \ \ � V \ i / / / -\ �� 45.5 LF 15" RCP - �� / - < ,I �A - V ���� s� A - \ \ \s \\�V\ \ \ +\ �� + �+� +++� �� - - V -� \ \ \ \ \\+\ +\+ +\ ��+ �_ / \ � / / / /\ � � @ 0.57% SLOPE ,-- -/5g�i / , / / / rah/ -------- -� ��� ��, A -- A \ �� \ _� \ \ \\ \ V �k\V A� \\ \\\+\+\*+\ +I+�+�+� / \ / / - � ✓�� / A \ � ) I ----- �� s �-, - v - �� \ \ \ \ \A \�°°� A \ \+ \t\\ \� / -� \ \ \ - \ ++++\+ \ + + \+ � I i � / / / FES IN: 548.36 � ��- / / - - -� - ����� � - - �- -� �� ---- \ \ \ \ \ \ \� \\ \ __ ) / / / APRON @ FES: � / A \ V A / - - _ - -_ � - - ) A A \ \ �� \ +V A + \ \+\ ------ \ \ / \ CLASS A EC STONE: \ \ \ \ / / / \ - _ - \ - - - + +�+ + - - - / + �\ \\ \ \ +\ \ \+ \+ �\ + \+ / i / \ - - ---- / /+ \ \ �\ \I \ �\ \ / A 3.75'Lx3.75'Wx12"T I' A \ \ \ - - - - - / + +\ + \+ \ A ✓ / / / C % FES OUT: 548.10 \ / / \ - - - \ - - - \ - - -- +-+ +_ + � -+ - ---- + � \ \� �+\ +\ \ \+ + \+ �/ \ ( - - - - - - YARD INLET 1.0: -+-+- + +- + �+ - - + \+ �+ � 1 � + 7- - / � / � APRON @FES: \ V \ V \ \ � � - - � - � / / � �) A �\ \+\ � \� -CLASS A EC STONE: A \ V \ \ \ \ \ V - - - _ e - WEIRS: 526.90 �+ �+� +� + +- _ ogs- + + + /+ + + +0 +\ + VA ) 0ss� \ 5'Lx6.25'Wx12"T ss � \ \ \ V V� - - - � INV OUT: 523.50 -+ _4-\+- -+_ +- -+-+ +-+ +�+ /+ to + + \+\ \ \ /� / -� - j ° \ ��� �- , v \ \ \\ V A \ --- � - + +� + �+ -+ -_ +-+ + +-+ �-+�+/, +i j A \+ \+\ +\ + ����� / / 55 \ � � � / \ \ A � - - � \+v +- + + + -+_ ± + -+- + + + + + +-- + +-, + \ +- + + / I ��� �/ /j/ - v -_ �v --� v-_ v v v A \ V\ \ � � - v - - A v \ �- � / v - - v v V A o V A A � v� + + *\+ + + +- + + + +� + I 1 + + +� I / / - / / / � _ / - +-+�+ + + + + +�+ + + +- + + + + + + 14 + 7- AREA SPACE i/ / - -� \ \ \ \ PRIVATE - \ AREA OF DISTURBANCE _ / / � - - A V A \ - ± +� � ,+ + - +- + +- + -+ -+ + -+- / A \ I / 295.504 SF OR 6.78 AC / / r ss_ A \ V A / I I /STORM EASEMENT + + + �+ k �+ �+ � + + -+- + -+- + -+ / j \ � �� �, A / / �� / s \ / (10' OFF SYSTEM) / - V �++� +- + +- - + +- + _+_ + / . / / / I I I l� T 1 i«OZI SB QVN-QIY� ON -/ / / / \� \� \ \ I I / A -_ G .� � -, A + -*- + -#- + � _+- + + + + / v--_- �6 v , l�Jl I ( / /� // /; I�� ss, -- -- -+_ - _ / - /v / / , )/L \ \ v v / / �' - -��1-1v� \� A\V I o 5� 0 - _ x \ /� lli v v v V v / / � v / \- � v r \ \ \ �) I ) V A / I � / �_ _��,__ - t/ - / / / /� v v v v v // � � / A 1 I _ -- y�v v v v v I� I I v`` v - =-� , 5= _- / v v - \ \ / � I / ) - A ��V A V / / � k� / - - - + 3 - �- - i / / / v A V v \ \ - __ / � / � x 7 ROAD SIDE -/- - v \ � �V I �) \ \ \ 5� : - - - _� - / / / / / /// /z � v \ o A DITCH � A � \ 1 �� - - - - � � / / / / // �A - 1-1 \ \ 5 \ s \� \ \\ \ x� - - - - 1 - - i / // 1 V A V \ ; 5ti V A - -- / ////� \ \ / / \ � \ V A \ S / _ A � I \ - �� V� \ 550 / 33 - - - / - // VA�!/ // / V /. +�� -+- � -+- +- +_ + + + + + + + � V \ \ \ V A V -, / - / - �� \ 3 / �/ v \v / + -+_- +- � -+ + - _+' + -+ + -0£s - �� %' _ �A,/�,j1 \ \ / /� O 4 < OPEN SPACE V A / / . - - \ 'O A \ V � / - .\ I A \ / i.I - CULVERT 1.0: '- -+ -+ +-_+-+ + -+_ +- + + +_+ - - -� �� ��/�//�/ z' \ s \ V A � V /\ / /� V \ \ V v 1 / // / / + +- -+- + + +- +-+ +-+ + _ ---- / /�/�� v v �, . \ �v I I �r - _ ___1. \ \ V A V A \ \ � - � ° V V A \ V I / / / / / - 71.9 LF 24" RCP �� -+ + -+ +_ � +mot + + +- + - - - % _///i/ � / - - � / /i \ \ V A v _ / ° / 2 \ \ / / I - � @ 2.09% SLOPE _+ �+ +-+- +- + _+ + +-gag - %-o -�_-- I \V A \\ \V A A AV \ V Av --�� -�- -� / / Q \ V \ V A \ I VA / �- _PRIVATE �-�+�+� + + +-+ + +-+ - --�---�/-jvii, jj� \ \,n \ \ \ - � - / � � \ \�0s FES IN: 538.50 \ � \ ]V A \ / \ ) I / \ � � I \ \ \ \� - - STORM EASEMENT +-+- -+� er -+ + + � + + � + - - ; �-�%i �'j j / \ V A V \ 1+ - _ �i i/� /// / \ \ v --- A v \ V A \ \ \ \ \ \ - APRON @ FES: / \ \ \ \ V A / A I 10' OFF SYSTEM �+ �+� + 1+ + -+ + + ice- /ice %i�/ Az / A" \ \ \ \ \ A V v � \ \ \ V A V �I r \ \ \A \ V A FES OUT: 522.00 / \ \ V A V ) ( ) +� + + T �r + -H -+- + _ /i�%� / i�j/ /�j V - - CLASS A EC STONE: / ,� �� \. - - - -- -ems +� +�+ +-+ + + + + -+ - - /65 /i// / / v ,,II / \ V \ \ - - i \ \ \ \ / / h. APRON @FES: A - - - - _ 5/ / / /�/ V V A V A - - - - ��� / 4.5'Lx4.5'Wx12"T V \ AV \ \ \ V �\ \V �V A ) 1g�- - - - �� �� _+ +-+ _ - Azz // �/ / /// // \ \ \ V A i \ \ \ V A \ V / / / o \ CLASS 1 RIP RAP: \ VA \ \ - / �i / / / \ V A V \ A \ A - - - - - \ / \ A \ 16'Lx18'Wx24"T V A VA \ / - - MONITOR VEGETATIVE SWALE FOR _ - ! z /, /��I- vi A \ \ V A V A V A \ / A \ /A/ - - \\ CULVERT 5.0: 7 \ I V A \ / / / / / / I / V \ A \ V A \\ \ \\v A VA� ---SIGNS A EROSION DURING FIRST ��� vz j jo/ / /// SD \ \ V / � � 54.7 LF 18" RCP---,, ,_ \ \ / / / / I \ V f \ \ \�V v VA \ \ A \ \ \ \ \ V A \ - -TWO YEARS AFTER CONSTRUCTION. _ i- _ - j /� / / o \ \ V A \ A V A \ / \ o o / /� \ \ - @ 1.01 SLOPE V J \ V \ / / / V \ \ \ \ \ /\ \\V A \ V \ \ V AA \ \\ \ V - .IF EROSION IS EVIDENT INSTALL - ; ; ; _-/\ \ v - v / \ \\ \ \ \ \V V A C- -� =��/i///// / / \ ) \ - - a M / . - - ,✓ - V A v - / V A \ \ V\�� A\ V A \\ \ \ \ -TURF REINFORCEMENT MATTING - - - i/ // / / / \ \ \ \\ - _ \ / \ �6 ° - - - - / / / / // \ \ \ \ \ \\ \\ \\�\\ \ \ \\ \ \\\ \\ \ \ \ \ALONG SWALE AND REVEGETATE. -_ - �5 - j5o/ i/ �// /j� \ / , \ V / \ - - -1 � �/ / /' / A// \\ \sue \ \VA V A-s A A - --- - i- _ i/// vI, , \ \ \ \ \ / \/ \ \ _ � � ,-. � � s � \\ /I \\ A\ s\ \ AV \ \\� \ \ \\ \V - - / ��/ // / / V ---- A\ / �_ V �- / / / / I \ \\ \\\ VA A � A A\ V A, 0Vv A \ -- - --- ' / /��_ //vi / J v , - - z_ ,�Pvv / v vv vv vv -- - - // - �5 vvv v v v v vv vv v - - / / �/ - gtig / / ) \ \ \ \ \ \ \ - - - i A \ \ \ \ \ \\ \ \ 7 - / / G I I A � V \ \ \\ \ \\ \ \\ \ -- - ���� ��� / o - / / / \\ \ \ \ V V -0I - --- / /. Q \ \ \ \ - i �--jig/ \ - 30 A o - _ - - A - o _ _ / / �/ 8 I I A� \ �V A A\ \\ V A\ \\ V V A V F � - - - - _/� -_ /- / I /) v \0 1 I1. o �bs - � \. // / ./ � I � I I \ � \ V1A � ttlA -:- /v / A �. / / I - { \ - - - - - AAA \ / / / / / ai I I � , \ \ A I \ V-495 � i _ i � / l - \ A \ - -- k. �/ i l l l l A \ �\�\�' _��� �� /\ I I / o� s � o/ / / 1 1 / I I / . / / - �/ l -I s �'"a �v v -�- -��--- vvv v v� - /`'bc �\ �/ / / / / I I I I s 11 /�/ l I II I 1 1 1 1 1 1 A +\ \ \A\� ♦ // /' / I FES IN: 537.00 I/ / �� h�' \ � V A \ V v /� ./ / I l l / I I I, I l l I I I I V V I /\ .� / '� / Z ( APRON @ FES: "s A FES OUT: 537.95 - \A\ / I I I I I / I V A / �/ � � � / CLASS B EC STONE: / / / % '\ APRON @ FES- v - - - \ � / / �� I I I I I I / I I I I I \t I , ) � /. / / / i / ✓ z / 6'Lx6'Wx18"T - CLASS A EC STONE. - � � / ( 10 I I I I % / / / / 555 29 I I . I A 6'Lx7.5'Wx12"T \ - - v � A� - - 7 . U I I ( � I. I � , . + + � / / / �� I I I I I � / I / / � - A � -' � / I I I I I /� I -- ,� I 1s - - � .� �� � � � I I I � I ) o \ \ ( I �� I I I I � I I i1' / / / �- I / - - - \ \ \ \ X� / . U i - - V - A 7--33 50 A 0 A I I x �/ / / / / / / A / I I I � / / � � � �� � � I I � I \� \ V A V A \ \ \ � � I ?, / �o / y- / �� / / / / / / i/ /� I I I I 11 I I I/ - \A \ � v 000 ,� I I I A� tom,A V A\\ I I I It / / P / ::..�... / / / / - \ - KCULVERT 4.0: o /./ / PUBLIC A \ �6os� �\ - �� s / A '\ V A s \ \ VA \ \� \� VA) I ) / /� \ - / / / / - _/ 51.9 LF 24" RCP a / STORM EASEMENT v VA \ V A A - v I / A \ \ V A A \ VA\ . \ y \ \ \ Van VA \ � I I I I P� / / / v V �� / � I O �\ \ \ \ \ \ \ \ /I / ) / @ 1.- 3 SLOPE I/ / 10' OFF SYSTEM, \ /1 -_\",A \ -� \ V A V\ \ \ \ o V I w .1- I / / / / - / / / � A / / - TYPICAL \ . I - - - V \ V A \, \\ V A \ AA \ o" 1 I ' . A \ / v \ / / / - - - / I I I I � / � � �1�./ / / - V � v v / / v \\ v v v v v v\ v v v� \ o� \ \ / v / \\ \ v V A\ \ /I P. \� \ V � / / - ,�� \ / � / / \ / \/ FES OUT:536.00 - - V A \ � / � " / \ \ \ \\ \ \� \ \\VA \ \ \�\ \ V� \ I . A / \ \ \ \ I A \ / I / / / / ALAUS B rl STONE: � A \ /A ° A \ \ \ V / \\ \ \ \ / - o I / / - % \ \ \\ \ \ \ \ \ \ \ \ V I I I V v / 55 - - �� / / / / 18 v v / / � v v vv v v��svv v vv vv \ \ v I ( � / / / \� - f I / / - v \ v v / vv vvvv\v v\ 11 v v_'vvv v v \�\ / � 12'Lx14'wx18"T � v � v v v v v v \ \\ V I \ / / � / / V / - - \ \ V A \ \ \ \ V v v STREAM \� VA \� \ \ V A / _ // I - l/ - -� / v V v % V \ V A \ V)i \ v v A v V / / / ---� --v ) I �I I I I / I /( --- � � v v v v/ v. v_, // j/ ,, �_ vvv �v � vv v v �, �,, <I \ �s� \ \ \ A V / / �V A \ \ \ s \ A / \ I 1 - ��' �_- / I +I I i -- v\� \ v � - A � \ \ 1 V A � \ - - / \ I N - - _ - ��v�V A V A - - / /. \ V A VA\ VA\, v \VAA \\ --- ��� \y \R\� \ \� \ \ 31 V A v v \ , / \ I / - \ \ - � v - � �, v v v \I vv w \vv �Avv v \� v v . I + � I o - -- - - - _ _-�--,vv v vvv vvv,, \A \ \ V \ VA V / \ V - / C, / /�i� A VA -- - A 17 V A� t- � A \\\ - r��� \\\, v �� cSp1 v A A v v v v v\ \ / _ / _ / 7\ I / J / /I �� \ \ �A - �� \ �v v v --- __-- - � v _ -- � �v vvV�\ \ \ \ 27 % / / /� \ V �� \ - \� \ --- - V A \� V A� v A A \ V�\ /' / \1 / / \ /� V \ \-- v v 1s tig--k \ \ ��\ - \ \ \ \ v '_09 -, v ssv \\ \ \ / 26 - -� V A / -/ / / A�/ / // / A \ v 1 � vv v \ v / - - . - � _ � � \- - - _vvvv v v\ (,- \ A \ \ v \ \ V AA VA V / / -- �� / / �/ / A \ % /� / A// �\ \ \� - s - �-�� ��--- -- A -� - �v\\ �I����-- \ \ FES IN: 534.50 / / / / / / / / / / - - - - -\� - - - - - -A V A i � \ \ V \ \ \ \ VA A \ -� A / A \ --- �� - ----- - �\ - �\ I L0-1, -� \ \ 25\ \ / // / / / / \ \\ \ - - P \ ��- �A/ �-_--1 1 \ \ \ V A APRON @INVERT: - / - �� V "� - V A - - - �\ V A �� � \ \\ ) \ V \ \ \\\ VA A CLASS 1 RIP RAP ��� - - / i AyeF / / / // / / A / \ \ � - ®\�\ � � -�- s__ � 15 � \ - �\-AA� V / A\\ \ S - � \ \ _ - \ V A VA \ 8'Lx8'Wx24" THICK / - - v / / / / / / / - / - - _ A \ \ - \ / \ � / / �/ V - - - - - - - A\V A V A _ _ A \ �540 A V \ ��� / \ \ \ \ \ V A - V / / / / / / / / / // / ---- - -A v� - - V� \ -- A V v / \\) 2 \ VI I \ \ \\ VA VA b�\ \ V A / \ -. / / //� /// / � 1 -� -� \A\- t� .A -- -�- - -- - �� \ --- -- �� V \ A A / \ \ \ s \ \A \ . \ I �- - \ / / / / /// / .5tipr / A -MONITOR VEGETAlVE SWALE FOR �- - - - - - - - - \ \ \ / _ �� ���� \ \,\A \A �))�)\I V A /\ ) \ \ V A A \ V A V / / A/i / / - - SIGNS OF EROSION DURING FlRST _Oic - - - _ - - - �" V V \ �� �\ / - , �� AA \ VAA \ VA \ l \\ \ V i/ / / // /// / / / - - TWO YEARS AFTER CONSTRUCTION. - - --- . � / �� v V A\ VA \ \ \ / \ \ / / A \ \ \ - Zi / / /// /// /�/ / - A \ \ 12 \ \V A \ \ \ / ( \ A V °�S ��nn5, / / / - - -- ITURFORENFORCEMENTTMATIINGL 1-1 ��s� � � \ V AA � \ - VA\ \ V AA \ \,A A % / / \ /\ 5 - / - ---- - - \-- \ 1 �� �\ \ \ V A \ \ \0+ A / \ / � / l / V A V i y / PUBLIC / / - - ALONG SWALE AND REVEGETATE. - - V A \ \ s V A / / \ \ V / V ° / STORM EASEMENT, i / - - - � ,- - - - - - v V A \ \ / �� / \ \ V A\ / / / / �,, �-, V -- - - � -� �� 1 \ A \ 1 � \ \ \\ V\\ \\V AA VA\VAS / / / / I \ \ vi / / I0' OFF SYSTEM, V A A VA - - - A - - - - �- - � 14 � � A A I \ \ \V A \ N V A \ / / / / _� /� 24 / \ \� v v vvv\VA �\ V - / / v//TYPICAL J --- ---�\� �v�o v---- _ ---- �Q A v v v vw\v \ v -� A V�VA \\ VAv v\ / / �� / / I , \ \ V V�\ / / // \/// � A - - - -`s- zs� - - ---- \ v v VA V A\ v // / v o A /- �_' �- V - - �\ vvv\v� �� _ - - - A\ \\\\ , A VA - - - - \ � A V 13 �\ V \ / /- / / / A V A A / // /// - / A I ���� �- --- --- - - - ' A V A \ - i - �� A \ \ / i i-- / A ,a A V�\ / / / - � - - - �\� - - - - � F V v � - / _ A\ \ \ / � A \ v \ /-' / ( < - � - �� v - �� - -\ - - - � - � �. " � v v v �� - - A v / / / / � / . ��\ \ V A \ / / �/ �- ---- - �� \ �� / V �� Vim- �-A -- \s VA os --_ ----� V A / i / / / / /-� \ VA / h ---- - - zs - - - - �V \ �� s > / / / 1 555� -1 - i % A \ \ \ \ / V) A � --- -- � � ���> - \ V �� �� - - \ - /� \ � / Z - ---_ / / \ I \ - \ \ \ \-\ -\ \� \ \ \\ \- \�\ �- _\// /\ h / / / / / � / / / / - �� t� V \-- �� - -- - / / A � I IX 7/ / _� � '_ � Ao � s � A � ��\� - -� -A � � - - - - � � - // \ / - / / / / / / FES: 531.00 � � s � A \ \ \ � �� - - - _7 I- � - � � - - A - - - -. -� �-1 - \ - _ - - _ _ - �/ / / / . �/ / a 1 I I I � - v �-� � '-- � � � � � v \ v 0� � �--\ - � - - � - � - _� s- - -� � �� - - g£g_ / / / �� / / / / �-'\ / / / _-APRON @FES: \ \ � A � -� A �� -� ��� � �- ---- ��� - --- --_i V / / I �� / / / \ � -CLASS 1 RIP RAP- v \ V A \ " A \ \ � �_, - A - � - 11�- - - - - / I / / ✓ / / - v v v \ v�A v v �� \ - -- - - -- -- - ---- - / / / /J� I I / - 16'Lx18'Wx24"T - \ A \ V \ V \ \ - V - - - A / ) ) 6 / v j�/ / / / / v v v v v V A / �� ��vIt \ - - -----��✓ \ �A \ / / / /� / I i / // // / A� �- A \ V A \ VA \ \ V ( / V\ \ A ��-� 0ZS - - � ------�0£g� ____,�_ i \ \ \ \ 23 // \ / . CULVERT 3.0: /// /l I \ �- _ bFs � \ \ \\\\\ \ \ \\\\ \ \ \� \ -- -----__- -__ - \ I / / / 91.8 LF 24" RCP \ \ \ \ \ \ \ \ \ \\ -- - -Il'l \ \ - ----------_-_-_ / v \ I 1 1 /� A/ / ✓ - -- � �v v v v v v v v v � � v ; - � --_---____ --_ % I � - V \ / A ( / / / ' @ 3.81 % SLOPE \ ( / � ��- � � A \ \ \ V / \ \ \ VA V A A \ \ \ V `� - - - - � - __ - -_ - - - \ sas- - / / 1 \ A / A - A \ \ \ \ VA \ \ \\ \ \ \ V / �- � A VA � - �� - -----------------_=- / / \ V A \ I I I / / A A V i -\ A \ \ V A A V A V A � � A V \ \ \ \ 1, \ \ - - � - - - - �- A - / / � v A \ \ �/ / A1�-� �\ sF, _ - \ v v v \ \ \ v v s� V OPEN SPACE v \ \ \ BUFFER -- _� - -- � ---- � - ------ - _ _ - ;, /� \ Y _ - - \ - - - - - - 520- _ _ _ / V \ ) I / / � ( / - - -_ _ 20 _ -_ A \ \ \ \ \ V A \ .�'�'�" - - = -7- - - - - ---- --- - / y I - - \ \ �' \ \ \ \ STREAM _ -a, - - ___-- / - - - - - - - - - / \ i rt- - - \ \ \ \ 1 \ \ \ \ \ \ I / / / -J'/ / / / -- -- -� -\-��s �- -- � -gig- - - - v' v -;_ - � --_ - __- __-_ �_ I i \ \ \ 1 / I\/ O./ / / /--_ \ -- -- - -- --- _- _ 5� ---- -- CALL BEFORE YOU DIG... IT'S THE LAW. GRAPHIC SCALE \ \ / I / I / \/ /o / � / - sos; - - ;�- - _ - _ _ _ � _ ; ., = _ _ 60 0 30 60 120 240 / / / / / / \ \ \ \ �,/ / //� / / \,z / / ����.. _��• - -- - -- -� ----- _ - -- ii� �_� - -- CALL N.C. ONE-CALL(1-800-632-4949) / / / / _ - - - - - - - - - - �% FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST V / % / / / / / �` / / / / / / \ o - - - -� - - _ - - - -� 5�"� _ _ - _ / / / / / /� \ \/ / ��' �'' STREAM \ - - - - -i -�� 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. / / / / / / / / / / / J"/ /�� /// / / i� % • � � - - - - /- 009- - - - - _- _ / �� NORTH CAROLINA GENERAL STATUTE 87-102 \ \ \ / \ /// \/ � C - - _ - -_-- -� ' - ( IN FEET ) �/ / z,5�\/ ////�/ / i�/��i�i� / // / \/\/ A� I I .. -�____ ----- \�\ l \----_-- � ��__ ,���- C- 1 inch = 60 ft. - / 17-002 Project Name (10/17/2019) Existing Proposed Gross Land Area (GLA): 1,818,140 1,818,140 Project Area: (GLA-surface water) 1,599,584 1,599,584 Impervious Area (site) Roof 992 0 Roadway 0 50,518 Parking / Driveway 9,212 2,581 Sidewalk 0 180 Impervious Area (lots 1-32) Roof each lot = 2,000 Driveway each lot = 1,000 Sidewalk, patio & hard.-apeeach lot = 500 Lot allowance each lot = 1,000 Impervious per lot each lot = 4,500 Total impervious for all lots 32 lots = 144,000 Impervious Area (lot 33) Driveway 16,092 Future Roadway 20,000 Future Development 60,408 Total Lot 33 Build Out 96,500 Pervious Area Landscaping / Other Pervious 1,589,380 1,305,805 Surface Water 218,556 218,556 Protected Forest 0 0 Other Areas Custom Land Cover 0 0 Land Taken Up by SCM 0 0 Total All Areas: 1,818,140 1,818,140 Total Impervious Area: 10,204 293,779 Total Impervious % of GLA 0.56% 16.16% Total Impervious % of Project Area 0.64% 18.37% a • U nn n� E I C:1 g@ �o - 9 8 . Q) O C i N W ram" (z U � �NMco�j co � a) cY) � = - � Cfl O U �(vL M O N ��Y U c,UMM z � N � C) MMa_ N .. c cz i W .. 2 N�IZLLLU J CCto %ZjZ" W N )� � a z; N J z . a U VO �P.��� z V �\, �� x J 0- O I-� I=� �� I� O � U P4 � y) � I- 4 �� �_) 4 W � 4 44 O Q< � P4 � 4 � m�U 0 U 0 0 a .. w w � w - 2 z 2 0 O O OCR w 0 Z v 0_ U C3 Z C) � O � LU U w cz 0 oc 0 O oc oc LLJ LU LU OC LU LU 0 0_ oc w 0_ 0_ rn_ rn_ rn rn_ O LLI O CD O O N O 00 CM C\I N N Q - � 0 �_ � - o O r- O O O r N O LU r N C0 � LO DATE: AUGUST 29, 2018 HORIZONTAL SCALE: V=60' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 WORKING THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. �%(�"W),(�§)� PRELIMINARY SUBDIVISION PLAN P:\17-002\17-002 Drawings\--Working\17-002 Working.dwg, C5.0 - G&SD Plan, 2/6/2020 8:53:36 AM F'AN(-LL IU#J I /U,)Ub, I /U,)UJ, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I / N u 01111111a �C h, wy sg VICINITY MAP i"=2,000' : T l (110Z) SB Q'VN—Q7Y� �N BRANDYWINE DR O,p 3 COORDINATE WITH ELECTRICAL PROVIDER TO RELOCATE POWER POLE PROPOSED 8" PVC PUBLIC WATER MAIN EXTENSION TERMINATION POINT OF EXISTING 8" / ORANGE-ALAMANCE PUBLIC WATER MAIN (PER ORANGE-ALAMANCE). FIELD VERIFY PRIOR TO START OF CONSTRUCTION. CALL BEFORE YOU DIG... IT'S THE LAW. CALL N.C. ONE-CALL(1-800-632-4949) FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 80 UTILITY PLAN NOTES 1. LOTS TO BE PUBLIC WATER AND INDIVIDUAL SEPTIC SYSTEMS. 2. ALL HOMES TO BE CONSTRUCTED WITH SPRINKLER SYSTEM DUE TO LOW FIRE FLOWS. BORE AND JACK USING 16" ENCASEMENT PIPE 8"X8" TEE 3x8" GATE VALVE BORE AND AREA OF DISTURBANCE 16" ENCASE 295,504 SF OR 6.78 AC / v► 8"X8" TEE �V 3x8" GATE VALVE o � / �9 a t / FIRE HYDRANT ASSEMBLY \ 6" LEG AND VALVE v / 8"X6" HYDRANT TEE / PROPOSED 8" PVC 9 0 PUBLIC WATER MAIN � x�o FIRE HYDRANT ASSEMBLY 6" LEG AND VALVE 8' X6" REDUCER GRAPHIC SCALE 40 80 160 ( IN FEET ) 1 inch = 80 ft. FIRE HYDRANT ASSEMBLY 3 8"X8" TEE 6" LEG AND VALVE / 3x8" GATE VALVE 8"X6" HYDRANT TEE PUBLIC STORM EASEMENT \ / 10' OFF SYSTEM, y TYPICAL � I 8" PVC PUBLIC WATER MAIN / O PUBLIC / STORM EASEMENT, 10' OFF SYSTEM, TYPICAL LL' ED . \ \ I., . Ld - Y Ld EXTEND MAIN ONE �\ \< — — — — // I I +\ �+ I + + + JOINT BEYOND TEE \ PROPOSED AND VALVE. CAP ACCESS _ — — — — — — — > \ I Q I + + \ EASEMENT /� \ I to I I ��\ J/ + � \+•\ : +; + + FIRE HYDRANT ASSEMBLY 6 LEG AND VALVE \ \20 8"X6" HYDRANT TEE /+ a - a EXTEND 8" PVC /+ MAIN ONE JOINT I I + BEYOND TEE AND FUTURE 8" PVC / VALVE. CAP WATER MAIN + + + \ \\ PRIVATE STORM EASEMENT 3 / >> J \ \ 1�1\\ \ (10' OFF SYSTEM) / + _ STREAM — ------ i ° j / BUFFER I PRIVATE STORM EASEMENT (10' OFF SYSTEM) FIRE HYDRANT ASSEMBLY HATCHED AREAS 6" LEG AND VALVE 8"X6" HYDRANT TEE SOILSINDICATE S SEPTIC E SOILS FOR SEPTIC 8" GATE VALVE a� 8" PVC PUBLIC+ + + /+/ / /•� :ss WATER MAIN + Igx�o � •� 2py� 2jx�o P \ FIRE HYDRANT ASSEMBLY + / 6" LEG AND VALVE \ �6" REDUCER I \ 500'+ • I STREAM BUFFER i' ♦ o ♦ ♦ :: — i STREAM 401 / ••• / .000 .41 � fir.: \•:,•.'._•• ' / I THERE ARE NO WETLANDS LOCATED ON SITE AS DETERMINED BY PILOT ENVIRONMENTAL INC. ON AUGUST 26, 2019 AND ACCEPTED 320 BY NCDEQ ON SEPTEMBER 20,2019 i r STREAM BUFFER + PROJECT INFORMATION: OWNER/DEVELOPER: ROBERT M. BRAME 2863 SOUTH JIM MINOR RD MEBANE, NC 27302 PROPERTIES INCLUDED IN PROJECT: 2679 JIM MINOR ROAD 2689 JIM MINOR ROAD PIN# 9802-59-3969 PIN# 9802-59-3974 PARCEL ID# 170308 PARCEL ID# 170309 TAX ID# 9-13-183 TAX ID# 9-13-184 2.8 ACRES 3.3 ACRES 2863 JIM MINOR ROAD 2817 JIM MINOR ROAD PIN# 9802-59-5721 PIN# 9802-59-4690 PARCEL ID# 170310 PARCEL ID# 159117 TAX ID# 9-13-185 TAX ID# 9-13-5 1.68 ACRES 14.25 ACRES CULBERSON LN S JIM MINOR ROAD PIN# 9802-58-4657 PIN# 9802-58-9583 PARCEL ID# 159114 PARCEL ID# 159116 TAX ID# 9-13-4A TAX ID# 9-13-4 6.01 ACRES 13.71 ACRES TOWNSHIP 9: THOMPSON DEED/PLAT REFERENCES: DB: 2823 PG: 0093 PB: 073 PG: 0293 DB: 3239 PG: 0957 DB: 2487 PG: 215 PB: 073 PG: 0293 SOILS: CnB2, CnC2, CnD2, CnE2 = CULLEN CLAY LOAM = GROUP C RvA = RIVERVIEW LOAM = HYDROLOGIC GROUP B WtB = WYNOTT-ENON COMPLEX = HYDROLOGIC GROUP C FEMA MAP #3710980200 K, EFFECTIVE 11/17/2017 FLOOD HAZARDS PRESENT TOTAL ACREAGE: 41.74 ACRES BY SURVEY TOTAL # PROPOSED LOTS: 33 LOTS AVERAGE LOT SIZE: 0.49 ACRES (NOT INCLUDING LOT #33) TOTAL OPEN SPACE: 530,223 SF OR 12.17 ACRES WINDING CREEK TRAIL: 316.09 LF FOREST CREEK LANE: 1,186.86 LF PATTON MILL LANE (PRIVATE): 1,271.77 LF U nn ��jj nn� � .� o 'i W r i cz U Coce) a)cm co a) Co Co'tt �NL17Oo O 0 Cz Z z � U CZ Cz W C N2aU-Lu J ����°'; z w W•4'/ ,zLIz z ) U z y- ������ d J 0- 0 �EEEI 0 x E 0 n�n� 0 Z W w 0:1 w 2 1.- 2 O O U O 0 Z C)C)w O w U W cn 0 D= 0 O D= o= W W W o= W W 0 W 0= W W W rn_ rn_ rn rn O Lu O O O N o O Q 0000 (.0 N N N 0 r r co 5 � o O O O O N r o LLJJ r N Co Lo D= DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=80' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 WORKING THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. C C) O 0 PRELIMINARY SUBDIVISION PLAN :\17-002\17-002 Drawings\__Working\17-002 Working.dwg, C6.0 - Utility Plan, 2/6/2020 8:53:41 AM FAK(_LL IU#J I /U,)Ub, I /U,)UJ, I /U.S I U, I n&1 14, 1 ny I I b, 15y I I / M I I / 65 I A, 8"X8" TEE 3x8;' GATE VALVE �' \ AV � 11-0 JQ �I 2 CI� CALL BEFORE YOU DIG... IT'S THE LAW. CALL N.C. ONE-CALL(1-800-632-4949) FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 9+50 570 568 566 564 562 560 558 556 554 z0 552 F_ 550 LLJ w 548 546 544 542 540 538 536 534 532 530 9+50 .J I / \ I I\/ 1 V 1 n�nn 1 n�rn 11 inn 11 �r,n 1 ?inn i Xz FES OUT' 53S. 95 � �VA� � �/ i / � / / / � / // // / / / APRON C� - CLASS A EC STONE: / 6'Lx7.5'Wx12"T / / � ' / / / / / / / / �/ / CQ Q J - ©K,p o�4��� �4vv 'z / - 4v� JIS /0x�z�_- 7� a �� ��q 76 0 \ ItppQ� \ V A V I I A i —4ZS 'vlls C5 ��•CC� r7 QItiLD \ \ \ v Z q I 60.0' op��� ," a -- / Q / `'� � 0�CA 1 7�rn 1 ��nn HIGH PT. STA: 10+36.79 HIGH PT ELEV: 552.92 PVI STA: 10+60.00 PVI STA: 12+70.00 PVI ELEV: 553.20 K: 9.29 PVI ELEV: K: 9.25 540.60 — LVC: 65.0. LVC: 55.00 I O � CDLn CO o Ln Ln N CD Ln Ln N O o0 — Ln Ln O N Ln +Lo M +n +In C7� +In + O O N N O W m_<o Ln I I LLI 7 w LLJ U cii > m bi U cii >v wo Ln >0+� > > ro Q w� m w Ln oU cn II w Q� E:iw Ln J � In m W o W II W J 00 + o 0> <J W 0-) Ln Ln CD W m + O J LLB 1.00% � 4 2.00% — U m Ln O o / 0-) 2.00% + w o + J W 0-) + Q _ 6 Cn00 DOg � — Y O 16" STEEL ~ 0_ w G �— Ln 36" COVER, ENCASEMENT PIPE MIN CAD PIPE m — 8 �gTFiQ IN \ 8"x8" TEE (3) 8" GATE VALVES � W— 2 �q/ti MECHANICAL JOINT RESTRAINTS & CONCRETE BLOCKING 0.05% 36" COVER FROM DITCH BOTTOM, MIN. 00 W J W" 0-) o- 8"x8" (3) 8" GATE VALVES TEE �2__ + MECHANICAL JOINT RESTRAINTS & �- CONCRETE BLOCKING W 10+00 10+50 11 +00 11 +50 12+00 12+50 13+00 1 _5+50 —570 — 568 — 566 — 564 — 562 — 560 —558 —556 —554 —552 —550 — 548 — 546 — 544 00% — 542 — 540 —538 —536 —534 —532 F-530 13+50 r7 Ln 00 r7 N O N O Lr) O CO r) O 00 rl O — 00 CO 00 O 00 0) 00 N 00 Ln N M N N O O 00 r- � N C7) O Lr) 0 0 0 Lr) Ln It � � ' r7 - Ln LC) 0 0 Ln 0 Ln 0 Ln 0 0 In Lr) Ln W L� W L� W L� W L� W L� W 1i LLI L� 10+00 10+50 11 +00 11 +50 12+00 12+50 13+00 O_ Ld LLJ ■ U nn n� O 'i W r � cz U cm Co � � OMCo':t� r, co O U C/) C\J U-) 7 O N Z _E N U .. W J N0-LL.W Co X to Lu N )O� 0UJI z; N J z VO z Y Fr J cl_ _ O + C W O � W l! L W O � w w al w OU 2 2 z O 0 D Z U C) w w U o Z U> -- O Lu U w ol: Cr) oc 0 O oc oc w wwoCww 0 D_ oc W D_ D_ rn rn rn m 0 w o 0 0 0 0 I_ N N N N N Q 0000 C\O CO CO CO \ C_\j \ 0 O O CDO r CM O W r CM Co Lo DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=40' VERTICAL SCALE: 1" = 4' PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 WORKING THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. GRAPHIC SCALE SHEET NO. 40 0 20 40 80 160 1 00 ( IN FEET) 1 inch = 40 ft. PRELIMINARY SUBDIVISION PLAN P:\17-002\17-002 Drawings\--Working\17-002 Working.dwg, P1.0 - Winding Crk. P&P, 2/6/2020 8:53:45 AM F'AN(-LL IU#J I /U,)Ub, I /U,)UJ, I /U,) I U, I n&1 14, 1 ny I I b, 15y I I / ly boo ��o II 0n� 0 Ali/ 'o - / A G 545 Lr 37 �. �� �� - CD o. � A - O, Cq �� � s t - T ��o � (,, � CO'' ----- \ �- o �o �C V.0 � C) C)oo��� �/20 �AILE I I I � � 1I 1I 19I 0 C6 n�-J�<)4/ GRAPHIC S \ I \ �o ,%�`� I I / �N FEE /`����� � 1 1�ch / 40 /ft. / cli -L7r, i n-Lnn IV � � \ � �� � I � I I I I � � I A ` � � \ \ `� � �� � A V ` // A \ V � V � � V ` � �\ ` � �►al I � 1 \I \ 3SL11 � ✓ - - _ � ELF, T F 6� � - / � � / qil, I I � \ � �� \ \ \ �,,� � X 0 - - - - 17+0 �- /8,1� 19+00 C - �A \ . 7- r , � •sus, / � � . / � II ; ! ; , �� .� -� ----- otis _ _ --� _ _ i ,- i VX --______ °�;r ------ -----_ / - STATION 1 n-L�7,n 1 1-Lnn 1 1-L�7n 1)-Lnn 1 1)-L�7,n 1-�-Lnn 1-�-L�7,n 1 d-Lnn 1 d-L�7,n 197,-Lnn 197,-L�7,n 1 F-Lnn 1 F-L�7,n 17-Lnn 17-L�7n 1Q-Lnn 1Q-L�7n 10-Lnn 10-L�7n I)n-Lnn 1)n-L�7,n a . U �� � �o .. O 'i W r:t L- cz U NC)� �O� j � N � CflO U U) (u L cr) O Ua)a U c,Z -E Cz Cz i W .. N L J 2 E LL L I O N 21 +00 21 +50 22 00 22 LOW PT. STA: 12+33.68 HIGH PT. STA: 17+82.19 - LOW PT ELEV: 538.25 - HIGH PT ELEV: 551.03 PVI STA: 10+40.61 PVI STA: 11+83.68 PVI STA: 14+94.67 PVI STA: 17+41.57 PVI STA: 20+00.00 PVI STA: 21+36.86 PVI ELEV: 544.78 PVI ELEV: 537.63 PVI ELEV: 540.74 PVI ELEV: 552.43 PVI ELEV: 547.26 PVI ELEV: 540.42 K: 20.00 K: 25.00 K: 40.14 K: 29.69 K: 33.33 K: 32.45 LVC: 40.00 LVC: 150.00 LVC: 150.00 LVC: 200.00 LVC: 100.00 LVC: 70.00 564 I 00 00 N7 00 cp 00 n(D 00100 n r- O 0') r O rn N r- LC) O r- - r- LC) re)O O c0 N O - O Lfl 6 00 Lfl 00 r7 O L6 O r6 C°� 00 o� +u") 00 Lnr7 +u) 00 C� pro +Ln a7 0) cow +Ln � �� +Ln �Ln +Ln O O Ln� +Ln 00 O 4 O� +U) N �� +Ln 0') 562 - 562N� Ln� +Ln o+Lo o+Ln N - LO CO � 00 (D 00 - O - LLJ O LLJ N N N LLJ Ld Ld LLJ z O O Ccn�; � 0 (n U > (n U > Uj U > &i U > QO� < O (n U > 66 U > U > V) U > (n U > (n j m > W m LLJ ; m m U W Ld ; m m U W W > m m 0+LO LLj r- Ln ; W W U m m U W ; m CO ; W W W Ld II > > Lli , 558 Q J J L� U) Li Ld > 00 LO Ln - 556CO W 556 w CD + m U� J W O N O 00 r- O Lo 554 + Ln N U CO rr6 u") > - - 0) LO LLJ Ld---�� I j - �� MAINTAIN 36" COVER, > w Ld o N 51.90 LF 24" RCP @ 1.93% MIN @ OF PIPE w 550 i - - - _ 2 009, O zQ 0 00 (CULVERT #5) 7 Q_ + - _ 00 CTION / 00 o O L7 INTERS + rn _ 4 + 548 N m 06 Ln II ELEV: 40.842 - O > n L0 w Ljj Q W .2 % N 3 00q, w w c~n w 18 RCP RCP 1.01 % ° 8 PVC WATER ; W (p (CULVERT MAIN \ J 544 �- � � Z-z 544 so + MAINTAIN 36" COVER, � N + 09, , 8"x6" HYDRANT TEE 6" GATE VALVE CONTINUES --�PTO CUL-DE-SAC MIN CAD OF PIPE -N + M MECHANICAL JOINT RESTRAINTS, - 542WATER �j + N / RODDING SEE HYDRANT &CONCRETE DETAIL. BLOCKING. \ / \ pVC � w 1.00% 84 ? ,% FR'i7q 18" CLEAR _ _ - \ ---- - -� MIN. 538 i i WATER MAIN - 8" PVC CALL BEFORE YOU DIG... IT'S THE LAW. 91.84 LF 24" RCP @ 3.81% (CULVERT #3.0) 8"x6" HYDRANT TEE 6" GATE VALVE MECHANICAL JOINT RESTRAINTS, RODDING & CONCRETE BLOCKING. CALL N.C. ONE-CALL(1-800-632-4949) FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST WATER CONTINUES TO CUL-DE-SAC 532 8%8" TEE (3) 8" GATE VALVES SEE HYDRANT DETAIL. MECHANICAL JOINT RESTRAINTS & 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 18" CLEAR MIN. CONCRETE BLOCKING t /J I UtUU I UtJU I I tUU I I tJU I ZtUU I ZtJU I JtUU I JtJV I'+tUU I'+tJU I JtUU I JtJU 10tUU 10tJU I /tUU I /tJU I OtUU I OtJU I ytUU I ytJU ZUtUU ZUtJU Z I tUU Z 1 tJU ZZtUU ZLt N O r` 00 0) 0) Ln LID 00 r) O 0) 0) r- 0) r` OD O N n r7 Lr) 00 r` 0')LC) N r- K) (0 0) (0 K) (0 't 0) 0 C0 O C0 Cr ('4n O N M o0 CO Co C'O � C'O N N� 7 - r-: C0 r It r` r- O n OD 00 OD rn r- N N N r7 N OD n r- O N 0) L0 C0 lr-� It n Ln O CO 00 CO 00 CO 00 r` 0) 00 0) 00 O 0) N r"') r` O 06 6 O O O 6 O Cn 6 06 06 r` (O N N c6 O � It n It rO r) n r) n r) rl) r) r) rM PO PO PO rO 4- n 't 't Lr) It Lr) � Lr) LC) Lr) LC) � Lr) It It It I It � � r) � 6 6 L0 L0 Ln L0 L0 L0 L0 L0 L0 L0 Lr) Ln Lr) Lr) Ln Lr) Lr) L0 Lr) L0 Lr) Lr) Lr) L0 Lr) Li) Lr) Li) Li) Lr) Ln Li) Lr) Li) Lr) Lr) Lr) Lr) Lr) Lr) Lr) Lr) Lr) Lr) Lr) Lr) Li) Ln W LI W LL_ W LL_ W LL W LL_ W LL_ W LL W LL_ W LL_ W LL_ W LL LL I LL W LL W LL_ W LL_ W LL_ W LL_ W LL_ W LL_ W LL_ W LL_ W LL_ W LL_ W LL_ W LL_ 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 w w al w O O U O 0 Z U OU w w U 0 Z U> U � w O � LLI C/A m 0 O m m w wwoCww 0 0_ oc W 0_ 0_ rn rn rn rn o w o 0 0 0 0 � N N N N N Q 0\0 C\O COC\I CO CD CO 0 rl- 6 o O CD CDO N r O Wr N C0 Ln DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=40' VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 WORKING THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. P 2 a 0 PRELIMINARY SUBDIVISION PLAN :\17-002\17-002 Drawings\__Working\17-002 Working.dwg, P2.0 - Forest Crk. P&P, 2/6/2020 8:53:53 AM — — 9+75 10+00 oR�q c ""/o "V'00, . 1 n��7,n / J �% / \ CO 1 inch = 40 ft. STATION 11 -1- nn 11 -1- �7n 1 ,)inn 1 1)-1- �7'n 1 -�_j_ nn 1 -� -I- �7'n 1 a-1- nn 1 a -I- �7'n 1 97, -1- nn 1 97, -1- �7'n 1 11-I- nn 9 FNcgS�MF � NT A /NG Sp4 �/S NAK(;LL IU#J I /U,)Ub, I /U,)UJ, I /U.) I U, I n& I I4, 1 ny11 b, 1 5y11 / V C c< 9 9A uo%. �T0'9R SSgRoN 54 o/41� oR s<4-6 Fo ®87o Ro�FRq� 2g� ToN 4 a. TR/ 7C,j �yo<F O F F (T hT cptiS pnp s'g s c'O qos /iy. O 9 q RoN g�8 �qNc \ \ U „t3 <c @ o N Ro F — U T— �F 550. F 2� _ui T i _ t (o Cz L� V ONW CV M CO @, � a)COCO'O U �N �NLOC` 0 •-► �� 550 x vJ U CU i CZ C .. Cz _Ji 1 II� U Cp 0 = C W J CV 2 o_ LL W �r \ vI Cf' M -- Cu / A 00 moz o \ s ®1C�F 7g /8., _zrn 00 M oo L) CID O Cf) O 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20 00 20 50 21+00 21+50 22 00 O W 578 CALL BEFORE YOU DIG... IT'S THE LAW. 578 CALL N.C. ONE-CALL(1-800-632-4949) 576 FOR LOCATION OF UNDERGROUND UTILITIES AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING GRADING OR TRENCHING. NORTH CAROLINA GENERAL STATUTE 87-102 572 \ \ \ \ MAINTAIN 36" COVER, MIN @ OF PIPE 568 _ — — 566 564 2 \ 560 558 CONTRACTOR TO LOCATE AND -CONNECT TO EXISTING 8" WATER MAIN PIPESHOULDER IN g•. p�C Wq — rER 556 554 MAINTAIN 36" COVER, MIN 0 q OF PIPE — — _ 554 — — _ n CAQ mp 8"x8" TEE (3) 8" GATE VALVES MECHANICAL JOINT RESTRAINTS & CONCRETE BLOCKING 36" COVER FROM DITCH BOTTOM, MIN. 8" PVC WATER MAIN 548 546 44 542 - 8"x8" TEE (3) 8" GATE VALVES MECHANICAL JOINT RESTRAINTS & CONCRETE BLOCKING 36" COVER FROM DITCH BOTTOM, MIN. 544 CAn 9+75 10+00 O W W W W U U U U U w al w z w 2 1.- 2 O U O D z O U 0U w IL U � I--- co w O cn � w 01: a) w oc wwoCww o O oc oc o rzocwrzlz w � rn o cm rn 0 cm rn 0 cmN m 0 0 0 N Q 0\0 C\O CO CO 7 CO o O 7 CD C CD Cm O CD LLu r N Cl) LO DATE: AUGUST 29, 2018 HORIZONTAL SCALE: 1"=40' VERTICAL SCALE: 1" = 4' PROJECT MANAGER: CPK DRAWN BY: CPK PROJECT NO: 17-002 DRAWING NAME: 17-002 WORKING THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON USE ON ANY OTHER THIS SITE DRAWING IS NOT FOR OR PROJECT. THE REPRODUCTION OR OTHER DRAWING IN WHOLE OR USE OF THIS IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00 19+50 20+00 20+50 21+00 21+50 22+00 LO a_ — a LO a- LO — a LO a LO a- � - a- � - a 0 W In L In - W W N N W Cb W r7 W W 0 W � - W � - W 0 W 0 0 W In W W ON r7 0� �� r7 0r" �N ro 00 �00 r7 0r) �rO r7 00) H� r7 0� DLO r7 0LO �rO r7 0n �N r7 00 H� r7 ON �N 0� r7 r7 O� �� r7 O� �O r7 O� H� 0� CO r7 0(0 N n 0(0 (» K) 00 I� r7 ON O O� r7 On � r7 0( N Dr- r- W > U W C D W ni W Cp of W W Cp W 0) W d) CY W 00 W LO � W w W LO of W LO W LO W � W LO of W n W 0 of W N W Ln W W In W > 0 O W� W Oj W I of W 00 W I W W I W > 0 rl W� of W r W I W CO W I W CO W I W CO W I W > 0 CO of W� W CO W I of W CO W I W > 0 In W� U LO > O a- LO > O it LO > O a- LO > O a- LO > O a- LO > � Ln > � Ln > O a > O a- 0 > O a- ll) U 0 Ln > W 0 > a_ > 0 Ln U 0 Ln > O a > a > a > O a- L() U 0 L() > O a > O a-Ln U W LC) U a_ U U a_ U a_ U a_ O U O U U U U a O� U O U O U FL � U O U a O U a U a_ a U a U a_ a_ f) 11 4 0 PRELIMINARY SUBDIVISION PLAN �17-002\17-002 Drawings\__Working\17-002 Working.dwg, P3.0 - Offsite Water P&P, 2/6/2020 8:54:01 AM FANULL lu#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / GROUND STABILIZATION AND MATERIALS HANDLING PRACTICES FOR COMPLIANCE WITH THE NCGO1 CONSTRUCTION GENERAL PERMIT Implementing the details and specifications on this plan sheet will result in the construction activity being considered compliant with the Ground Stabilization and Materials Handling sections of the NCGO1 Construction General Permit (Sections E and F, respectively). The permittee shall comply with the Erosion and Sediment Control plan approved by the delegated authority having jurisdiction. All details and specifications shown on this sheet may not apply depending on site conditions and the delegated authority having jurisdiction. SECTION E: GROUND STABILIZATION Required Ground Stabilization Timeframes Stabilize within this Site Area Description many calendar Timeframe variations days after ceasing land disturbance (a) Perimeter dikes, swales, ditches, and 7 None perimeter slopes (b) High Quality Water 7 None (HQW) Zones (c) Slopes steeper than If slopes are 10' or less in length and are 3:1 7 not steeper than 2:1, 14 days are allowed -7 days for slopes greater than 50' in length and with slopes steeper than 4:1 -7 days for perimeter dikes, swales, (d) Slopes 3:1 to 4:1 14 ditches, perimeter slopes and HQW Zones -10 days for Falls Lake Watershed -7 days for perimeter dikes, swales, (e) Areas with slopes ditches, perimeter slopes and HQW Zones flatter than 4:1 14 -10 days for Falls Lake Watershed unless there is zero slope Note: After the permanent cessation of construction activities, any areas with temporary ground stabilization shall be converted to permanent ground stabilization as soon as practicable but in no case longer than 90 calendar days after the last land disturbing activity. Temporary ground stabilization shall be maintained in a manner to render the surface stable against accelerated erosion until permanent ground stabilization is achieved. GROUND STABILIZATION SPECIFICATION Stabilize the ground sufficiently so that rain will not dislodge the soil. Use one of the techniques in the table below: Temporary Stabilization • Temporary grass seed covered with straw or other mulches and tackifiers • Hydroseeding • Rolled erosion control products with or without temporary grass seed • Appropriately applied straw or other mulch • Plastic Sheeting Permanent Stabilization • Permanent grass seed covered with straw or other mulches and tackifiers • Geotextile fabrics such as permanent soil reinforcement matting • Hydroseeding • Shrubs or other permanent plantings covered with mulch • Uniform and evenly distributed ground cover sufficient to restrain erosion • Structural methods such as concrete, asphalt or retaining walls • Rolled erosion control products with grass seed POLYACRYLAMIDES (PAMS) AND FLOCCULANTS 1. Select flocculants that are appropriate for the soils being exposed during construction, selecting from the NC DWR List of Approved PAMS/Flocculants. 2. Apply flocculants at or before the inlets to Erosion and Sediment Control Measures. 3. Apply flocculants at the concentrations specified in the NC DWR List of Approved PAMS/Flocculants and in accordance with the manufacturer's instructions. 4. Provide ponding area for containment of treated Stormwater before discharging offsite. 5. Store flocculants in leak -proof containers that are kept under storm -resistant cover or surrounded by secondary containment structures. EQUIPMENT AND VEHICLE MAINTENANCE 1. Maintain vehicles and equipment to prevent discharge of fluids. 2. Provide drip pans under any stored equipment. 3. Identify leaks and repair as soon as feasible, or remove leaking equipment from the project. 4. Collect all spent fluids, store in separate containers and properly dispose as hazardous waste (recycle when possible). 5. Remove leaking vehicles and construction equipment from service until the problem has been corrected. 6. Bring used fuels, lubricants, coolants, hydraulic fluids and other petroleum products to a recycling or disposal center that handles these materials. LITTER, BUILDING MATERIAL AND LAND CLEARING WASTE 1. Never bury or burn waste. Place litter and debris in approved waste containers. 2. Provide a sufficient number and size of waste containers (e.g dumpster, trash receptacle) on site to contain construction and domestic wastes. 3. Locate waste containers at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 4. Locate waste containers on areas that do not receive substantial amounts of runoff from upland areas and does not drain directly to a storm drain, stream or wetland. 5. Cover waste containers at the end of each workday and before storm events or provide secondary containment. Repair or replace damaged waste containers. 6. Anchor all lightweight items in waste containers during times of high winds. 7. Empty waste containers as needed to prevent overflow. Clean up immediately if containers overflow. 8. Dispose waste off -site at an approved disposal facility. 9. On business days, clean up and dispose of waste in designated waste containers. PAINT AND OTHER LIQUID WASTE 1. Do not dump paint and other liquid waste into storm drains, streams or wetlands. 2. Locate paint washouts at least 50 feet away from storm drain inlets and surface waters unless no other alternatives are reasonably available. 3. Contain liquid wastes in a controlled area. 4. Containment must be labeled, sized and placed appropriately for the needs of site. 5. Prevent the discharge of soaps, solvents, detergents and other liquid wastes from construction sites. PORTABLE TOILETS 1. Install portable toilets on level ground, at least 50 feet away from storm drains, streams or wetlands unless there is no alternative reasonably available. If 50 foot offset is not attainable, provide relocation of portable toilet behind silt fence or place on a gravel pad and surround with sand bags. 2. Provide staking or anchoring of portable toilets during periods of high winds or in high foot traffic areas. 3. Monitor portable toilets for leaking and properly dispose of any leaked material. Utilize a licensed sanitary waste hauler to remove leaking portable toilets and replace with properly operating unit. EARTHEN STOCKPILE MANAGEMENT 1. Show stockpile locations on plans. Locate earthen -material stockpile areas at least 50 feet away from storm drain inlets, sediment basins, perimeter sediment controls and surface waters unless it can be shown no other alternatives are reasonably available. 2. Protect stockpile with silt fence installed along toe of slope with a minimum offset of five feet from the toe of stockpile. 3. Provide stable stone access point when feasible. 4. Stabilize stockpile within the timeframes provided on this sheet and in accordance with the approved plan and any additional requirements. Soil stabilization is defined as vegetative, physical or chemical coverage techniques that will restrain accelerated erosion on disturbed soils for temporary or permanent control needs. ONSITE CONCRETE WASHOUT STRUCTURE WITH LINER SANDBAGS (TYP.) OR STAPLES 10 MIL SILT FENCE SIDE SLOP LINING C SANDBAGS (TYP.) (TYP. OR STAPLES O X J< HIGH � COHESIVE Sc LOW FILTRATION SOIL BERM CLEARLY MARKED SIGNAGE SECTION A -A CONCRETE NOTING DEVICE (18"X24" MIN.) NOTES: WASHOUT 1. ACTUAL LOCATION DETERMINED IN FIELD 2. THE CONCRETE WASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75% OF THE STRUCTURES CAPACITY. PLAN 3.CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. BELOW GRADE WASHOUT STRUCTURE NOT TO SCALE 10' MIN SANDBAGS (TYP.) B OR STAPLES 10 MIL HIGH O 0 PLASTIC LINING LOHESIVE FILTRATION 0 �1TYP) E SLOP SOIL BERM o SECTION B-B SANDBAGS (TYP.) OR STAPLES NOTES: 1. ACTUAL LOCATION DETERMINED IN FIELD CLEARLY MARKED SIGNAGE CONCRETE NOTING DEVICE (18"X24" MIN.) 2. THE CONCRETE WASHOUT WASHOUT STRUCTURES SHALL BE MAINTAINED WHEN THE LIQUID AND/OR SOLID REACHES 75% OF THE STRUCTURES CAPACITY TO PROVIDE ADEQUATE HOLDING CAPACITY WITH A MINIMUM 12 PLAN INCHES OF FREEBOARD. 3.CONCRETE WASHOUT STRUCTURE NEEDS TO BE CLEARY MARKED WITH SIGNAGE NOTING DEVICE. ABOVE GRADE WASHOUT STRUCTURE NOT TO SCALE CONCRETE WASHOUTS 1. Do not discharge concrete or cement slurry from the site. 2. Dispose of, or recycle settled, hardened concrete residue in accordance with local and state solid waste regulations and at an approved facility. 3. Manage washout from mortar mixers in accordance with the above item and in addition place the mixer and associated materials on impervious barrier and within lot perimeter silt fence. 4. Install temporary concrete washouts per local requirements, where applicable. If an alternate method or product is to be used, contact your approval authority for review and approval. If local standard details are not available, use one of the two types of temporary concrete washouts provided on this detail. 5. Do not use concrete washouts for dewatering or storing defective curb or sidewalk sections. Stormwater accumulated within the washout may not be pumped into or discharged to the storm drain system or receiving surface waters. Liquid waste must be pumped out and removed from project. 6. Locate washouts at least 50 feet from storm drain inlets and surface waters unless it can be shown that no other alternatives are reasonably available. At a minimum, install protection of storm drain inlet(s) closest to the washout which could receive spills or overflow. 7. Locate washouts in an easily accessible area, on level ground and install a stone entrance pad in front of the washout. Additional controls may be required by the approving authority. 8. Install at least one sign directing concrete trucks to the washout within the project limits. Post signage on the washout itself to identify this location. 9. Remove leavings from the washout when at approximately 75% capacity to limit overflow events. Replace the tarp, sand bags or other temporary structural components when no longer functional. When utilizing alternative or proprietary products, follow manufacturer's instructions. 10. At the completion of the concrete work, remove remaining leavings and dispose of in an approved disposal facility. Fill pit, if applicable, and stabilize any disturbance caused by removal of washout. HERBICIDES, PESTICIDES AND RODENTICIDES 1. Store and apply herbicides, pesticides and rodenticides in accordance with label restrictions. 2. Store herbicides, pesticides and rodenticides in their original containers with the label, which lists directions for use, ingredients and first aid steps in case of accidental poisoning. 3. Do not store herbicides, pesticides and rodenticides in areas where flooding is possible or where they may spill or leak into wells, stormwater drains, ground water or surface water. If a spill occurs, clean area immediately. 4. Do not stockpile these materials onsite. HAZARDOUS AND TOXIC WASTE 1. Create designated hazardous waste collection areas on -site. 2. Place hazardous waste containers under cover or in secondary containment. 3. Do not store hazardous chemicals, drums or bagged materials directly on the ground. NCGO1 GROUND STABILIZATION AND MATERIALS HANDLING EFFECTIVE: 04/01/19 .4 0 U U W T � N a) M U �OCflO � (u LO M O UMMY CO CZ Z T T N U a���e 4) U CZ CZ CC U x G O N CZ N2aLLLU _(0 W N LLI � z �w z� LU U z ¢' - U U z_° EE J a_ N � Q x o E-+ C/D C/D w 0 mIUUUUU w LU °w� 2 1.-- 2 O U O O O w D Z U U U � LU cn � 01: co oc o O oc oc LU LU LU oC LU LU o IioCLUa_a_ ���!�?o w o0000 CO cm cm cm N o ,---- �cococo`0 r- r- C3 N 000ro LU r N co � Lo DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. rlx)� W,(� §)� P:\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D1.0 NCGO1 Details, 2/6/2020 8:54:08 AM PRELIMINARY SUBDIVISION PLAN FANULL IU#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION A: SELF -INSPECTION Self -inspections are required during normal business hours in accordance with the table below. When adverse weather or site conditions would cause the safety of the inspection personnel to be in jeopardy, the inspection may be delayed until the next business day on which it is safe to perform the inspection. In addition, when a storm event of equal to or greater than 1.0 inch occurs outside of normal business hours, the self -inspection shall be performed upon the commencement of the next business day. Anytime when inspections were delayed shall be noted in the Inspection Record. Frequency Inspect (during normal Inspection records must include: business hours) (1) Rain gauge Daily Daily rainfall amounts. maintained in If no daily rain gauge observations are made during weekend or good working holiday periods, and no individual -day rainfall information is order available, record the cumulative rain measurement for those un- attended days (and this will determine if a site inspection is needed). Days on which no rainfall occurred shall be recorded as "zero." The permittee may use another rain -monitoring device approved by the Division. (2) E&SC At least once per 1. Identification of the measures inspected, Measures 7 calendar days 2. Date and time of the inspection, and within 24 3. Name of the person performing the inspection, hours of a rain 4. Indication of whether the measures were operating event > 1.0 inch in properly, 24 hours 5. Description of maintenance needs for the measure, 6. Description, evidence, and date of corrective actions taken. (3) Stormwater At least once per 1. Identification of the discharge outfalls inspected, discharge 7 calendar days 2. Date and time of the inspection, outfalls (SDOs) and within 24 3. Name of the person performing the inspection, hours of a rain 4. Evidence of indicators of stormwater pollution such as oil event > 1.0 inch in sheen, floating or suspended solids or discoloration, 24 hours 5. Indication of visible sediment leaving the site, 6. Description, evidence, and date of corrective actions taken. (4) Perimeter of At least once per If visible sedimentation is found outside site limits, then a record site 7 calendar days of the following shall be made: and within 24 1. Actions taken to clean up or stabilize the sediment that has left hours of a rain the site limits, event > 1.0 inch in 2. Description, evidence, and date of corrective actions taken, and 24 hours 3. An explanation as to the actions taken to control future releases. (5) Streams or At least once per If the stream or wetland has increased visible sedimentation or a wetlands onsite 7 calendar days stream has visible increased turbidity from the construction or offsite and within 24 activity, then a record of the following shall be made: (where hours of a rain 1. Description, evidence and date of corrective actions taken, and accessible) event > 1.0 inch in 2. Records of the required reports to the appropriate Division 24 hours Regional Office per Part III, Section C, Item (2)(a) of this permit of this permit. (6) Ground After each phase 1. The phase of grading (installation of perimeter E&SC stabilization of grading measures, clearing and grubbing, installation of storm measures drainage facilities, completion of all land -disturbing activity, construction or redevelopment, permanent ground cover). 2. Documentation that the required ground stabilization measures have been provided within the required timeframe or an assurance that they will be provided as soon as possible. NOTE: The rain inspection resets the required 7 calendar day inspection requirement. PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION 6: RECORDKEEPING 1. E&SC Plan Documentation The approved E&SC plan as well as any approved deviation shall be kept on the site. The approved E&SC plan must be kept up-to-date throughout the coverage under this permit. The following items pertaining to the E&SC plan shall be documented in the manner described: Item to Document Documentation Requirements (a) Each E&SC Measure has been installed Initial and date each E&SC Measure on a copy and does not significantly deviate from the of the approved E&SC Plan or complete, date locations, dimensions and relative elevations and sign an inspection report that lists each shown on the approved E&SC Plan. E&SC Measure shown on the approved E&SC Plan. This documentation is required upon the initial installation of the E&SC Measures or if the E&SC Measures are modified after initial installation. (b) A phase of grading has been completed. Initial and date a copy of the approved E&SC Plan or complete, date and sign an inspection report to indicate completion of the construction phase. (c) Ground cover is located and installed Initial and date a copy of the approved E&SC in accordance with the approved E&SC Plan or complete, date and sign an inspection Plan. report to indicate compliance with approved ground cover specifications. (d) The maintenance and repair Complete, date and sign an inspection report. requirements for all E&SC Measures have been performed. (e) Corrective actions have been taken Initial and date a copy of the approved E&SC to E&SC Measures. Plan or complete, date and sign an inspection report to indicate the completion of the corrective action. 2. Additional Documentation In addition to the E&SC Plan documents above, the following items shall be kept on the site and available for agency inspectors at all times during normal business hours, unless the Division provides a site -specific exemption based on unique site conditions that make this requirement not practical: (a) This general permit as well as the certificate of coverage, after it is received. (b) Records of inspections made during the previous 30 days. The permittee shall record the required observations on the Inspection Record Form provided by the Division or a similar inspection form that includes all the required elements. Use of electronically -available records in lieu of the required paper copies will be allowed if shown to provide equal access and utility as the hard -copy records. (c) All data used to complete the Notice of Intent and older inspection records shall be maintained for a period of three years after project completion and made available upon request. [40 CFR 122.41] PART III SELF -INSPECTION, RECORDKEEPING AND REPORTING SECTION C: REPORTING 1. Occurrences that must be reported Permittees shall report the following occurrences: (a) Visible sediment deposition in a stream or wetland. (b) Oil spills if: • They are 25 gallons or more, • They are less than 25 gallons but cannot be cleaned up within 24 hours, • They cause sheen on surface waters (regardless of volume), or • They are within 100 feet of surface waters (regardless of volume). (a) Releases of hazardous substances in excess of reportable quantities under Section 311 of the Clean Water Act (Ref: 40 CFR 110.3 and 40 CFR 117.3) or Section 102 of CERCLA (Ref: 40 CFR 302.4) or G.S. 143-215.85. (b) Anticipated bypasses and unanticipated bypasses. (c) Noncompliance with the conditions of this permit that may endanger health or the environment. 2. Reporting Timeframes and Other Requirements After a permittee becomes aware of an occurrence that must be reported, he shall contact the appropriate Division regional office within the timeframes and in accordance with the other requirements listed below. Occurrences outside normal business hours may also be reported to the Division's Emergency Response personnel at (800) 662-7956, (800) 858-0368 or (919) 733-3300. Occurrence Reporting Timeframes (After Discovery) and Other Requirements (a) Visible sediment • Within 24 hours, an oral or electronic notification. deposition in a . Within 7 calendar days, a report that contains a description of the stream or wetland sediment and actions taken to address the cause of the deposition. Division staff may waive the requirement for a written report on a case -by -case basis. • If the stream is named on the NC 303(d) list as impaired for sediment - related causes, the permittee may be required to perform additional monitoring, inspections or apply more stringent practices if staff determine that additional requirements are needed to assure compliance with the federal or state impaired -waters conditions. (b) Oil spills and • Within 24 hours, an oral or electronic notification. The notification release of shall include information about the date, time, nature, volume and hazardous location of the spill or release. substances per Item 1(b)-(c) above (c) Anticipated • A report at least ten days before the date of the bypass, if possible. bypasses [40 CFR The report shall include an evaluation of the anticipated quality and 122.41(m)(3)] effect of the bypass. (d) Unanticipated • Within 24 hours, an oral or electronic notification. bypasses [40 CFR e Within 7 calendar days, a report that includes an evaluation of the 122.41(m)(3)] quality and effect of the bypass. (e) Noncompliance • Within 24 hours, an oral or electronic notification. with the conditions • Within 7 calendar days, a report that contains a description of the of this permit that noncompliance, and its causes; the period of noncompliance, may endanger including exact dates and times, and if the noncompliance has not health or the been corrected, the anticipated time noncompliance is expected to environment[40 continue; and steps taken or planned to reduce, eliminate, and CFR 122.41(I)(7)] prevent reoccurrence of the noncompliance. [40 CFR 122.41(I)(6). • Division staff may waive the requirement for a written report on a case -by -case basis. NCGO I SELF -INSPECTION, RECORDKEEPING AND REPORTING EFFECTIVE: 04/01/19 C� U �o � o .� o U 'i 0 W L T 1:t� U a)N���j a)OCO t Cfl U UaaY U 00 co Z T T co U � CZ V CZ c O X O N CZ W J c\Ofu_w It CE:(0 W N W � Z W z °- WU Z a ' 0-_ - U Up Z_ Y Fr J a � C DO W x W� � � W w �+ W L) W F� mIUUUUU w w °w� 2 1-- 2 O C)O O w D Z C)OU U � w cn � 01: cn oc o O oc oc w wwoCww o wocwrZrZ rn rn rn rn 0 w CD CD CD CD 0 N N - N - N - N - co co co (.0 N O r r- r-- O N O O O r O W r N co - Lo DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. P:\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D1.1 NCGO1 Details, 2/6/2020 8:54:12 AM PRELIMINARY SUBDIVISION PLAN F-AKI;tL IU#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / COIR FIBER WATTLE \V MATTI 2' ( MAX . ) COIR FIBER WATTLE DETAIL P Pv% e Inset A BACK \ SLOPE ISOMETRIC VIEW 2' UPSLOPE STAKE NOTES: USE MINIMUM 12 IN. DIAMETER COIR FIBER (COCONUT FIBER) WATTLE. USE 2 FT. WOODEN STAKES WITH A 2 IN. BY 2 IN. NOMINAL CROSS SECTION. ONLY INSTALL WATTLE(S) TO A HEIGHT IN DITCH SO FLOW WILL NOT WASH AROUND WATTLE AND SCOUR DITCH SLOPES AND AS DIRECTED. EDGE OF PAVEMENT INSTALL A MINIMUM OF 2 UPSLOPE STAKES AND 4 DOWNSLOPE STAKES AT AN ANGLE TO WEDGE WATTLE TO BOTTOM OF DITCH. PROVIDE STAPLES MADE OF 0.125 IN. DIAMETER STEEL WIRE FORMED INTO A U SHAPE NOT LESS THAN 12" IN LENGTH. INSTALL STAPLES APPROXIMATELY EVERY 1 LINEAR FOOT ON BOTH SIDES OF WATTLE AND AT EACH END TO SECURE IT TO THE SOIL. INSTALL MATTING IN ACCORDANCE WITH SECTION 1631 OF THE STANDARD SPECIFICATIONS. MATTING 7��`�V2' DOWNSLOPE STAKE CROSS SECTION VEE DITCH 2 IN. TURAL GROUND 2' UPSLOPE FLOW -- STAKE NATURAL GROUND �1/�2 2> 22 ,• � � MATTING - 2' DOWNSLOPE CROSS SECTION STAKE TRAPEZOIDAL DITCH CONSTRUCTION SPECIFICATIONS: 1. REMOVE AND PROPERLY DISPOSE OF ALL TREES, BRUSH, STUMPS, AND OTHER OBJECTIONABLE MATERIAL. 2. ENSURE THAT THE MINIMUM CONSTRUCTED CROSS SECTION MEETS ALL DESIGN REQUIREMENTS. 3. ENSURE THAT THE TOP OF THE DIKE IS NOT LOWER AT ANY POINT THAN THE DESIGN ELEVATION PLUS THE SPECIFIED SETTLEMENTS. 4. PROVIDE SUFFICIENT ROOM AROUND DIVERSIONS TO PERMIT MACHINE RE -GRADING AND CLEANOUT. 5. VEGETATE THE RIDGE IMMEDIATELY AFTER CONSTRUCTION, UNLESS IT WILL REMAIN IN PLACE LESS THAN 30 WORKING DAYS. INSPECT TEMPORARY DIVERSIONS ONCE A WEEK AND AFTER EVERY RAINFALL. MAINTENANCE: IMMEDIATELY REMOVE SEDIMENT FROM THE FLOW AREA AND REPAIR THE DIVERSION RIDGE. CAREFULLY CHECK OUTLETS AND MAKE TIMELY REPAIRS AS NEEDED. WHEN THE AREA PROTECTED IS PERMANENTLY STABILIZED, REMOVE THE RIDGE AND THE CHANNEL TO BLEND WITH THE NATURAL GROUND LEVEL AND APPROPRIATELY STABILIZE IT. 2' MIN. COMPACTED SOIL~I 18" MIN 6' TYPICAL TEMPORARY DIVERSION DITCH NTS INSET A INSET B TOP VIEW 12' MINIMUM CONSTRUCTION ENTRANCE/EXIT CONSTRUCTION SPECIFICATIONS: 1.) CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS, AND OTHER OBJECTIONABLE MATERIAL AND PROPERLY GRADE IT. 2.) PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS SHOWN ON THE PLANS, AND SMOOTH IT. 3.) PROVIDE DRAINAGE TO CARRY WATER TO A SEDIMENT TRAP OR OTHER SUITABLE OUTLET. 4.) USE GEOTEXTILE FABRICS BECAUSE THEY IMPROVE THE STABILITY OF THE FOUNDATION IN LOCATIONS SUBJECT TO SEEPAGE OR HIGH WATER TABLE. MAINTAIN THE GRAVEL PAD IN A CONDITION TO PREVENT MUD OR SEDIMENT FROM LEAVING THE CONSTRUCTION SITE. THIS MAY REQUIRE PERIODIC TOPDRESSING WITH 2-INCH STONE. AFTER EACH RAINFALL, INSPECT ANY STRUCTURE USED TO TRAP SEDIMENT AND CLEAN IT OUT AS NECESSARY. IMMEDIATELY REMOVE ALL OBJECTIONABLE MATERIALS SPILLED, WASHED, OR TRACKED ONTO PUBLIC ROADWAYS. 8' MAX. STANDARD STRENGTH FABRIC WITH WIRE FENCE 6' MAX. EXTRA STRENGTH FABRIC WITHOUT WIRE FENCE STEEL POST 18- 24"- WIRE FENCE{ 24"' STEEL POST NATURAL GROUND 24" 8" DOWN & 4" FORWARD ALONG THE TRENCH WIRE FENCE FILTER FABRIC BACKFILL TRENCH AND COMPACT THOROUGHLY UPS 8" MIN. --� 4" MIN. PLASTIC OR WIRE TIES NATURAL GROUND FILTER FABRIC NATURAL GROUND CONSTRUCTION SPECIFICATIONS: U MATERIALS 1. USE A SYNTHETIC FILTER FABRIC OF AT LEAST 95% BY WEIGHT OF POLYOLEFIN OR POLYESTER, WHICH IS CERTIFIED BY THE MANUFACTURER OR SUPPLIER AS CONFIRMING TO THE REQUIREMENTS IN ASTM D 6461, WHICH IS SHOWN IN PART IN TABLE 6.62B OF THE EROSION AND SEDIMENT CONTROL PLANNING AND DESIGN MANUAL PUBLISHED BY NC DEQ_ SYNTHETIC FILTER FABRIC SHOULD CONTAIN ULTRA VIOLET RAY INHIBITORS AND STABILIZERS TO PROVIDE A MINIMUM OF 6 MONTHS OR EXPECTED USABLE CONSTRUCTION LIFE AT A TEMPERATURE RANGE OF 0 TO 120° F. 2. ENSURE THAT POSTS FOR SEDIMENT FENCES ARE 1.25 LB/LINEAR FT MINIMUM STEEL WITH A MINIMUM LENGTH OF 5'. MAKE SURE THAT STEEL POSTS HAVE PROJECTIONS TO FACILITATE FASTENING THE FABRIC. 3. FOR REINFORCEMENT OF STANDARD STRENGTH FILTER FABRIC, USE WIRE FENCE WITH A MINIMUM 14 GAUGE AND A MAXIMUM MESH SPACING OR 6 INCHES. CONSTRUCTION 1. CONSTRUCT THE SEDIMENT BARRIER OF STANDARD STRENGTH OR EXTRA STRENGTH SYNTHETIC FILTER FABRICS. 2. ENSURE THAT THE HEIGHT OF THE SEDIMENT FENCE DOES NOT EXCEED 24 INCHES ABOVE THE GROUND SURFACE. (HIGHER FENCES MAY IMPOUND VOLUMES OF WATER SUFFICIENT TO CAUSE FAILURE OF THE STRUCTURE.) 3. CONSTRUCT THE FILTER FABRIC FROM A CONTINUOUS ROLL CUT THE LENGTH OF THE BARRIER TO AVOID JOINTS. WHEN JOINTS ARE NECESSARY, SECURELY FASTEN THE FILTER CLOTH ONLY AT A SUPPORT POST WITH 4 FEET MINIMUM OVERLAP TO THE NEXT POST. 4. SUPPORT STANDARD STRENGTH FILTER FABRIC BY WIRE MESH FASTENED SECURELY TO THE UPSLOPE SIDE OF THE POSTS. EXTEND THE WIRE MESH SUPPORT TO THE BOTTOM OF THE TRENCH. FASTEN THE WIRE REINFORCEMENT, THEN FABRIC ON THE UPSLOPE SIDE OF THE FENCE POST. WIRE OR PLASTIC ZIP TIES SHOULD HAVE A MINIMUM 50 POUND TENSILE STRENGTH. 5. WHEN A WIRE MESH SUPPORT FENCE IS USED, SPACE POSTS A MAXIMUM OF 8 FEET APART. SUPPORT POSTS SHOULD BE DRIVEN SECURELY INTO THE GROUND A MINIMUM OF 24 INCHES. 6. EXTRA STRENGTH FILTER FABRIC WITH 6 FT POST SPACING DOES NOT REQUIRE WIRE MESH SUPPORT FENCE. SECURELY FASTEN THE FILTER FABRIC DIRECTLY TO POSTS. WIRE OR PLASTIC ZIP TIES SHOULD HAVE A MINIMUM 50 POUND TENSILE STRENGTH. 7. EXCAVATE A TRENCH APPROXIMATELY 4 INCHES WIDE AND 8 INCHES DEEP ALONG THE PROPOSED LINE OF POSTS AND UPSLOPE FROM THE BARRIER. 8. PLACE 12 INCHES OF THE FABRIC ALONG THE BOTTOM AND SIDE OF THE TRENCH. 9. BACKFILL THE TRENCH WITH SOIL PLACED OVER THE FILTER FABRIC AND COMPACT. THROUGH COMPACTION OF THE BACKFILL IS CRITICAL TO SILT FENCE PERFORMANCE. 10. DO NOT ATTACH FILTER FABRIC TO EXISTING TREES. MAINTENANCE: INSPECT SEDIMENT FENCES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. SHOULD THE FABRIC OF A SEDIMENT FENCE COLLAPSE, TEAR, DECOMPOSE OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE FENCE. TAKE CARE TO AVOID UNDERMINING THE FENCE DURING CLEANOUT. REMOVE ALL FENCING MATERIALS AND UNSTABLE SEDIMENT DEPOSITS AND BRING THE AREA TO GRADE AND STABILIZE IT AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED. NOTE: STRUCTURAL STONE SHALL BE (CLASS "B") STONE FOR EROSION CONTROL PURPOSES. SEDIMENT CONTROL STONE SHALL BE #5 OR #57 STONE SILT FENCE 1'-6" MIN. 1 2 �� x �OW ENT CONTROL-' LSTRUCTURAL STONE STONE CROSS SECTION SILT FENCE DETAIL NC DEQ FIGURE 6.62A / NTS 2' TOP VIEW SILT FENCE OUTLET PROJECT INFORMATION PROJECT DESCRIPTION THE PURPOSE OF THE PROJECT IS TO CONSTRUCT A 33 LOT SINGLE-FAMILY HOME SUBDIVISION WITH ASSOCIATED ROADWAYS AND UTILITIES. THE SITE IS LOCATED ON SOUTH JIM MINOR ROAD IN ALAMANCE COUNTY NORTH CAROLINA AND CONSISTS OF 6 SEPARATE PARCELS. THEY CAN BE IDENTIFIED AS PARCEL ID#S 170308, 170309, 170310, 159117, 159114, AND 159116. SITE DESCRIPTION THE 6 PARCELS THAT MAKE UP THE PROJECT TOTAL 43.01 ACRES BY SURVEY. THE TOTAL AREA IS LARGELY VACANT AND WOODED EXCEPT FOR A MOBILE HOME AND SHEDS WITH ASSOCIATED DRIVEWAY WHICH IS LOCATED ON PARCEL ID# 159116. THERE IS A CLEARED 85' WIDE PSNC GAS PIPELINE EASEMENT ON THE NORTH SIDE OF THE PROJECT AND A STREAM RUNNING ALONG THE WEST AND SOUTH SIDES OF THE PROJECT. THE STREAM TO THE SOUTH HAS AN ASSOCIATED FEMA FLOOD PLAIN. NO DEVELOPMENT IS PLANED IN THE VICINITY OF THE STREAM, STREAM BUFFER OR FLOOD PLAIN. THE SITE IS THE REAR HALF OF A PREVIOUSLY DEVELOPED 25.26 ACRE WAREHOUSE FACILITY. THE DEVELOPMENT SITE IS COVERED IN SCRUB PINE AND BRUSH WITH AN EAST WEST RIDGELINE THAT SPLITS DRAINAGE ROUGHLY IN HALF AND DIRECTS RUNOFF TO THE NORTHERN PROPERTY LINES AND SOUTHERN PROPERTY LINES. SLOPES VARY GREATLY ACROSS THE SITE WITH STEEPER SLOPES BEING NEAR THE STREAM. THE SITE DRAINS TO THE SOUTH AND WEST TOWARD THE STREAM. ADJACENT PROPERTY NEIGHBORING PROPERTIES ARE ALL LARGER SIZE SINGLE FAMILY HOME LOTS OR LARGE UNDEVELOPED TRACTS OF LAND. NARRATIVE PLANNED EROSION AND SEDIMENTATION CONTROL PRACTICES 1. SEDIMENT FENCE/ SILT FENCE OUTLETS SEDIMENT FENCE WILL BE CONSTRUCTED ALONG THE DOWNSTREAM PERIMETER OF THE SITE. SILT FENCE OUTLETS ARE PROVIDED AT THE LOW POINTS ALONG THE SEDIMENT FENCE LINE OR ARE POSITIONED WITH SILT FENCE CUT-OFFS TO REDUCE FLOWS ALONG THE SILT FENCE. 2. TEMPORARY DIVERSIONS TEMPORARY DIVERSIONS ARE PROVIDED ALONG THE EDGES OF FILL SLOPES TO DIRECT SEDIMENT LADEN WATER TO THE SEDIMENT BASINS FOR FILTRATION AND TO PREVENT EROSION OF FILL SLOPES AND PREVENT RUNOFF FROM ENTERING THE UNDERGROUND STORAGE CHAMBERS PRIOR TO STABILIZATION OF PARKING FACILITIES. 3. INLET PROTECTION INLET PROTECTION IS PROVIDED AT ALL ENTRANCES TO THE STORM SEWER SYSTEM TO PREVENT SEDIMENTATION OF THE PROPOSED UNDERGROUND STORAGE PIPES. 4. CONSTRUCTION ENTRANCE/EXIT A TEMPORARY CONSTRUCTION ENTRANCE/EXIT WILL BE CONSTRUCTED OFF OF SPRING FOREST DRIVE IN THE LOCATION OF THE PERMANENT ENTRANCE. 5. RIP RAP APRON PERMANENT STABILIZATION WILL BE INSTALLED BELOW PIPE OR FLUME OUTLETS AS INDICATED. 6. SKIMMER SEDIMENT BASINS/SEDIMENT TRAPS SKIMMER SEDIMENT BASINS/SEDIMENT TRAPS ARE PROVIDED AT THE LOW POINTS OF THE SITE TO FILTER SEDIMENT LADEN RUNOFF PRIOR TO DISCHARGE. CONSTRUCTION SCHEDULE 1. OBTAIN PLAN APPROVAL AND OTHER APPLICABLE PERMITS. 2. HOLD PRECONSTRUCTION CONFERENCE PRIOR TO STARTING CONSTRUCTION. 3. CLEAR AS NECESSARY TO INSTALL PERIMETER MEASURES, CONSTRUCTION ENTRANCE/EXIT, TEMPORARY DIVERSIONS AND SEDIMENT TRAPS/BASINS AS SHOWN ON SHEET C4.0. 4. INSTALL ALL PERIMETER MEASURES, CONSTRUCTION ENTRANCE/EXIT, AND SEDIMENT TRAPS/BASINS INDICATED 5. CLEAR REMAINDER OF SITE. 6. INSTALL ALL CULVERTS AND ASSOCIATED INLETS. INSTALL INLET PROTECTION AS NOTED. 7. ROUGH GRADE NEW ROADWAY AND PRIVATE DRIVE. 8. UPON COMPLETION OF FILL, STABILIZE BACKSLOPES IMMEDIATELY. 9. INSTALL WATERMAIN IN SOUTH JIM MINOR ROAD. STABILIZE DISTURBED AREAS ON THE NORTHERN SIDE OF SOUTH JIM MINOR ROAD IMMEDIATELY. 10. EXTEND WATERMAIN ALONG NEW ROADWAY. TEST AND CHLORINATE PRIOR TO FINE GRADING ROADWAY. 11. GRADE SUBGRADE OF ROADWAY AND PRIVATE DRIVE. 12. INSTALL BASE AND PAVING. 13. FINE GRADE FILL SLOPES AND DITCHES. INSTALL TEMPORARY AND PERMANENT LINERS AS NOTED. 14. INSTALL PERMANENT APRONS AND STABILIZE ALL REMAINING DISTURBED AREAS. 15. INSPECT ALL EROSION AND SEDIMENT CONTROL PRACTICES WEEKLY AND AFTER RAINFALL EVENTS. MAKE NEEDED REPAIRS IMMEDIATELY. 16. AFTER SITE IS STABILIZED, REMOVE ALL TEMPORARY EROSION CONTROL MEASURES AND INSTALL PERMANENT VEGETATION ON THE DISTURBED AREAS. MAINTENANCE PLAN 1. CHECK ALL EROSION AND SEDIMENT CONTROL PRACTICES FOR STABILITY AND OPERATION FOLLOWING EVERY RAINFALL PRODUCING RUNOFF BUT IN NO CASE LESS THAN ONCE EVERY WEEK. MAKE ANY NEEDED REPAIRS IMMEDIATELY TO MAINTAIN ALL PRACTICES AS DESIGNED. FOLLOW ALL REQUIREMENTS OF NPDES PHASE II PERMIT. 2. REMOVE SEDIMENT FROM BEHIND SILT FENCE OUTLETS AND STONE FILTERS WHEN STORAGE CAPACITY HAS BEEN APPROXIMATELY 50% FILLED. CLEAN OR REPLACE GRAVEL ON OUTLETS WHEN THE WATER POOLS AND IS NO LONGER DRAINING PROPERLY. 3. CLEAN TRAPS WHEN SEDIMENT ACCUMULATES TO WITHIN ONE FOOT OF THE WEIR CREST ELEVATION. CHECK TRAPS FOR EVIDENCE OF BYPASS OR BREACH AFTER EACH RAINFALL AND REPAIR IMMEDIATELY. 4. SEED AND STABILIZE ALL DISTURBED AREAS IN ACCORDANCE WITH STABILIZATION TABLE PRESENTED ON THIS SHEET. C� U o O U 'i CU W y-- T m U N CN ,l! C) O co Co m:t 0 U �C\JLoCo O UmmY U � z T T N * U )��� a > C: N Cz �--� U O x � O CU Cz W iD CV 0- LL_ W It C'") Ir W N w� Z W Z� WZ z Q a _ - U z� F J a _ ICL. 0 O 0 W h--I 0 cf) 0 44 44 �r , mIUUUUU �i a w w w 2 O 2 2 U O O w D Z U 3 or- O or-w U w En Or - co o= o O o= o= w wwocww o w or_ www rn rn rn rn o w o 0 0 0 0 cmN N N N CO CO CO N O r f- f- O N O O O r O W r N Co � Lo DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. P:\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D1.2 EC Details, 2/6/2020 8:54:23 AM PRELIMINARY SUBDIVISION PLAN rHKC;tL IU�J 1 /UJUtS, 1 /UJUy, I /U,51U, 15y114, 15y1 Ib, 15y11 / -DEWATERING CONCRETE BLOCK \,C-cf)o 0'.00- o ° O °°o 00 OCP - - ,- °o O fa fa 0 O� �� O o 00 00 0 0 0 �O 1-60 o O��oo�°g°�o oo rD o(D �o. 0 o ��° o g °�o o ° °° ° 00�oo 000° 000 oo° o0 O oo O °� ° Oo 00 ° °r0 O / o O -� 0o 0 (D oo o� o �o 0 ooDD 2:1 SLOPE, GRAVEL FILTER 4' MIN. ALL AROUND WIRE SCREEN TEMPORARY SEDIMENT POOL DEWATERING 1' MIN. 2' MAX. DRAINAGE - SEDIMENT 11 1I STRUCTURE CONSTRUCTION SPECIFICATIONS 1. LAY ONE BLOCK ON EACH SIDE OF THE STRUCTURE ON ITS SIDE IN THE BOTTOM ROW TO ALLOW POOL DRAINAGE. THE FOUNDATION SHOULD BE EXCAVATED AT LEAST 2 INCHES BELOW THE CREST OF THE STORM DRAIN. PLACE THE BOTTOM ROW OF BLOCKS AGAINST THE EDGE OF THE STORM DRAIN FOR LATERAL SUPPORT AND TO AVOID WASHOUTS WHEN OVERFLOW OCCURS. IF NEEDED, GIVE LATERAL SUPPORT TO SUBSEQUENT ROWS BY PLACING 2 X 4 WOOD STUDS THROUGH BLOCK OPENINGS. 2. CAREFULLY FIT HARDWARE CLOTH OR COMPARABLE WIRE MESH WITH 1/2-INCH OPENINGS OVER ALL BLOCK OPENINGS TO HOLD GRAVEL IN PLACE. 3. USE CLEAN GRAVEL, 3/4- TO 1/2-INCH IN DIAMETER, PLACED 2 INCHES BELOW THE TOP OF THE BLOCK ON A 2:1 SLOPE OR FLATTER AND SMOOTH IT TO AN EVEN GRADE. DOT #57 WASHED STONE IS RECOMMENDED. 4. IF ONLY STONE AND GRAVEL ARE USED, KEEP THE SLOPE TOWARD THE INLET NO STEEPER THAN 3:1. LEAVE A MINIMUM 1-FT WIDE LEVEL STONE AREA BETWEEN THE STRUCTURE AND AROUND THE INLET TO PREVENT GRAVEL FROM ENTERING INLET. ON THE SLOPE TOWARD THE INLET, USE STONE 3 INCHES IN DIAMETER OR LARGER. ON THE SLOPE AWAY FROM THE INLET USE 1/2 - 3/4-INCH GRAVEL (NCDOT #57 WASHED STONE) AT A MINIMUM THICKNESS OF 1 FT. MAINTENANCE INSPECT THE BARRIER AFTER EACH RAIN AND MAKE REPAIRS AS NEEDED. REMOVE SEDIMENT AS NECESSARY TO PROVIDE ADEQUATE STORAGE VOLUME FOR SUBSEQUENT RAINS. WHEN THE CONTRIBUTING DRAINAGE AREA HAS BEEN ADEQUATELY STABILIZED, REMOVE ALL MATERIALS AND ANY UNSTABLE SOIL, AND EITHER SALVAGE OR DISPOSE OF IT PROPERLY. BRING THE DISTURBED AREA TO PROPER GRADE, THEN SMOOTH AND COMPACT IT. APPROPRIATELY STABILIZE ALL BARE AREAS AROUND THE INLET. BLOCK AND GRAVEL INLET PROTECTION NTS DESIGN SETTLED TOP OF BERM @ CONSTANT GRADE WEIR ELEVATION / TOP OF STORAGE EXISTING GRADE EXCAVATED AREA BOTTOM @ _ CONSTANT GRADE 12" MIN OF NCDOT #5 OR #57 WASHED STONE MIN 3600 CU FT/ACRE B SETTLED 21" Ti MIN \ 1. FT - --------- 5 MAXF ILL FI 2' TO 3.5' ------ F' CROSS SECTION 4' MIN. A: DISTANCE BELOW GRADE, TYPICALLY 1.5' MIN. B: DISTANCE ABOVE GRADE, VARIES C: TOTAL DESIGN DEPTH FROM EXISTING GRADE D: INLETS TO TRAP @ OR ABOVE WEIR ELEVATION 1.5 FT MIN. 5' MAX �7 \2:1 SIDE SLOPE MAX 1:1 SIDE / SLOPE MAX LFILTER FABRIC -OVERFILL 6" FOR SETTLEMENT I I I -I I EMERGENCY BY-PASS 6" BELOW SETTLED TOP OF DAM NATURAL GROUND '3' MIN.' PLAN VIEW TEMPORARY SEDIMENT TRAP N TS CONSTRUCTION SPECIFICATIONS: 1. CLEAR, GRUB, AND STRIP THE AREA UNDER THE EMBANKMENT OF ALL VEGETATION AND ROOT MAT. REMOVE ALL SURFACE SOIL CONTAINING HIGH AMOUNTS OF ORGANIC MATTER AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL ALL OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL AREA. 2. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY VEGETATION, ORGANIC MATTER, AND OTHER OBJECTIONABLE MATERIAL. PLACE THE FILL IN LIFTS NOT TO EXCEED 9 INCHES AND MACHINE COMPACT IT. OVER FILL THE EMBANKMENT 6 INCHES TO ALLOW FOR SETTLEMENT. 3. CONSTRUCT THE OUTLET SECTION IN THE EMBANKMENT. PROTECT THE CONNECTION BETWEEN THE RIPRAP AND THE SOIL FROM PIPING BY USING FILTER FABRIC OR A KEYWAY CUTOFF TRENCH BETWEEN THE RIPRAP STRUCTURE AND THE SOIL. - PLACE THE FILTER FABRIC BETWEEN THE RIPRAP AND SOIL. EXTEND THE FABRIC ACROSS THE SPILLWAY FOUNDATION AND SIDES TO THE TOP OF THE DAM; OR - EXCAVATE A KEYWAY TRENCH ALONG THE CENTERLINE OF THE SPILLWAY FOUNDATION EXTENDING UP THE SIDES TO THE HEIGHT OF THE DAM. THE TRENCH SHOULD BE AT LEAST 2 FT DEEP AND 2 FT WIDE WITH 1:1 SIDE SLOPES. 4. CLEAR THE POND AREA BELOW THE ELEVATION OF THE CREST OF THE SPILLWAY TO FACILITATE SEDIMENT CLEANOUT. 5. ALL CUT AND FILL SLOPES SHOULD BE 2:1 OR FLATTER. 6. ENSURE THAT THE STONE (DRAINAGE) SECTION OF THE EMBANKMENT HAS A MINIMUM BOTTOM WIDTH OF 3 FT AND MAXIMUM SIDE SLOPES OF 1:1 THAT EXTEND TO THE BOTTOM OF THE SPILLWAY SECTION. 7. CONSTRUCT THE MINIMUM FINISHED STONE SPILLWAY BOTTOM WIDTH, AS SHOWN ON THE PLANS, WITH 2:1 SIDE SLOPES EXTENDING TO THE TOP OF THE OVER FILLED EMBANKMENT. KEEP THE THICKNESS OF THE SIDES OF THE SPILLWAY OUTLET STRUCTURE AT A MINIMUM OF 21 INCHES. THE WEIR MUST BE LEVEL AND CONSTRUCTED TO GRADE TO ASSURE DESIGN CAPACITY. 8. MATERIAL USED IN THE STONE SECTION SHOULD BE A WELL -GRADED MIXTURE OF STONE WITH A D50 SIZE OF 9 INCHES (CLASS B EROSION CONTROL STONE IS RECOMMENDED) AND A MAXIMUM STONE SIZE OF 14 INCHES. THE STONE MAY BE MACHINE PLACED AND THE SMALLER STONES WORKED INTO THE VOIDS OF THE LARGER STONES. THE STONE SHOULD BE HARD, ANGULAR, AND HIGHLY WEATHER -RESISTANT. 9. DISCHARGE INLET WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION. USE TEMPORARY SLOPE DRAINS OR DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT -LADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY (REFERENCES: RUNOFF CONTROL MEASURES AND OUTLET PROTECTION). 10. ENSURE THAT THE STONE SPILLWAY OUTLET SECTION EXTENDS DOWNSTREAM PAST THE TOE OF THE EMBANKMENT UNTIL STABLE CONDITIONS ARE REACHED AND OUTLET VELOCITY IS ACCEPTABLE FOR THE RECEIVING STREAM. KEEP THE EDGES OF THE STONE OUTLET SECTION FLUSH WITH THE SURROUNDING GROUND, AND SHAPE THE CENTER TO CONFINE THE OUTFLOW STREAM (REFERENCES: OUTLET PROTECTION). 11. DIRECT EMERGENCY BYPASS TO NATURAL, STABLE AREAS. LOCATE BYPASS OUTLETS SO THAT FLOW WILL NOT DAMAGE THE EMBANKMENT. 12. STABILIZE THE EMBANKMENT AND ALL DISTURBED AREAS ABOVE THE SEDIMENT POOL AND DOWNSTREAM FROM THE TRAP IMMEDIATELY AFTER CONSTRUCTION (REFERENCES: SURFACE STABILIZATION). 13. SHOW THE DISTANCE FROM THE TOP OF THE SPILLWAY TO THE SEDIMENT CLEANOUT LEVEL (ONE-HALF THE DESIGN DEPTH) ON THE PLANS AND MARK IT IN THE FIELD. 14. INSTALL POROUS BAFFLES AS SPECIFIED IN PRACTICE 6.65, POROUS BAFFLES. MAINTENANCE: INSPECT TEMPORARY SEDIMENT TRAPS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (1/2 INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE TRAP TO ITS ORIGINAL DIMENSIONS WHEN THE SEDIMENT HAS ACCUMULATED TO ONE-HALF THE DESIGN DEPTH OF THE TRAP. PLACE THE SEDIMENT THAT IS REMOVED IN THE DESIGNATED DISPOSAL AREA AND REPLACE THE PART OF THE GRAVEL FACING THAT IS IMPAIRED BY SEDIMENT. CHECK THE STRUCTURE FOR DAMAGE FROM EROSION OR PIPING. PERIODICALLY CHECK THE DEPTH OF THE SPILLWAY TO ENSURE IT IS A MINIMUM OF 1.5 FT BELOW THE LOW POINT OF THE EMBANKMENT. IMMEDIATELY FILL ANY SETTLEMENT OF THE EMBANKMENT TO SLIGHTLY ABOVE DESIGN GRADE. ANY RIPRAP DISPLACED FROM THE SPILLWAY MUST BE REPLACED IMMEDIATELY. AFTER ALL SEDIMENT -PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL UNSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND STABILIZE PROPERLY (REFERENCES: SURFACE STABILIZATION). \ \ o / V_ \\ \\ \ CLASS /AP NATURAL GROUND B RIPR/ �C> RIP RAP HEADWALL FILTER BERM NCDOT #5 OR #57 WASHED STONE 1-11 Fv ' PERSPECTIVE VIEW NO SCALE PIPE INVERT AREAS TO BE DISTURBED SEDIMENT STORAGE NOTE: (CUT, FILL, ETC.) FLOOD STORAGE ZONE RIP RAP HEADWALL, 1' MIN GRAVEL & RIP RAP FILTER BERM HEIGHT FROM ROAD SHOULDER BASIN DETAIL IS DESIGNED TO 1' 3' NATURAL PROTECT EXISTING PIPE INVERTS FCOW 2 3 - - GROUND THAT DRAIN 10 ACRES OR LESS. --- 1.5' - - --FLOWS -- _ - - NOTE: 1cLISS e RIP -RAP DIMENSIONS ARE MINIMUM ACCEPTABLE UNLESS NCDOT #5 OR #57 WASHED STONE OTHERWISE NOTED. MAX. SEDIMENT DEPTH(CLEAN OUT POINT) SECTION THRU BASIN, FILTER AND CULVERT PIPE NO SCALE (EXISTING PIPE INVERTS) STD. No. ROCK PIPE INLET PROTECTION 6.55.2 SEE DENR STANDARDS & SPECS. FOR COMPLETE DESIGN CRITERIA & MAINTENANCE PVC END CAP \ PVC ELBOW PVC VENT PIPE \ WATER SURFACE • • • • PVC END CAP SCHEDULE 40 PVC PIPE PVC TEE PVC PIPE FLEXIBLE 1/2" HOLES IN HOSE UNDERSIDE END VIEW SKIMMER SEDIMENT BASINS ARE NEEDED WHERE DRAINAGE AREAS ARE TOO LARGE FOR TEMPORARY TRAPS. DO NOT LOCATE THE SKIMMER SEDIMENT BASIN IN INTERMITTENT OR PERENNIAL STREAMS. n A rri r /Tvn\ INLE INLET ZONE 25% OF SURFACE AREA SCHEDULE 40 PVC PIPE ORIFICE PLATE PVC TEE BOTTOM SURFACE FRONT VIEW "C" ENCLOSURE WATER ENTRY UNIT TLET OUTLET ZONE 25% OF SURFACE AREA SURFACE AREA SURFACE AREA POROUS BAFFLES IN SEDIMENT TRAP , BASIN SUPPORT ROPE TO WIRE TO PREVENT SAGGING SUPPORT POST, 24" INTO BOTTOM OR SIDE STAKE TO SUPPORT WIRE I COIR MESH OR SIMILAR, STAPLED OR TRENCHED INTO BOTTOM OR SIDE CROSS-SECTION OF POROUS BAFFLES CONSTRUCTION SPECIFICATION: 1. GRADE THE BASIN SO THAT THE BOTTOM IS LEVEL FRONT TO BACK AND SIDE TO SIDE. 2. INSTALL POSTS ACROSS THE WIDTH OF THE SEDIMENT TRAP (PRACTICE 6.62, SEDIMENT FENCE). 3. STEEL POSTS SHOULD BE DRIVEN TO A DEPTH OF 24 INCHES, SPACED A MAXIMUM OF 4 FEET APART, AND INSTALLED UP THE SIDES OF THE BASIN AS WELL. THE TOP OF THE FABRIC SHOULD BE 6 INCHES HIGHER THAT THE INVERT OF THE SPILLWAY. TOPS OF BAFFLES SHOULD BE 2 INCHES LOWER THAN THE TOP OF THE BERMS. 4. INSTALL AT LEAST THREE ROWS OF BAFFLES BETWEEN THE INLET AND THE OUTLET DISCHARGE POINT. BASINS LESS THAN 20 FEET IN LENGTH MAY USE 2 BAFFLES. 5. ADD A SUPPORT WIRE OR ROPE ACROSS THE TOP OF THE MEASURE TO PREVENT SAGGING. 6. WRAP POROUS MATERIAL, LIKE JUTE BACKED BY COIR MATERIAL, OVER THE TOP WIRE. THE FABRIC SHOULD HAVE FIVE TO TEN PERCENT OPENINGS IN THE WEAVE. ATTACH FABRIC TO A ROPE AND A SUPPORT STRUCTURE WITH ZIP TIES, WIRE, OR STAPLES. 7. THE BOTTOM AND SIDES OF THE FABRIC SHOULD BE ANCHORED IN A TRENCH OR PINNED WITH 8-INCH EROSION CONTROL MATING STAPLES. 8. DO NOT SPLICE THE FABRIC, BUT USE A CONTINUOUS PIECE ACROSS THE BASIN MAINTENANCE INSPECT BAFFLES AT LEAST ONCE A WEEK AND AFTER EACH RAINFALL. MAKE ANY REQUIRED REPAIRS IMMEDIATELY. BE SURE TO MAINTAIN ACCESS TO THE BAFFLES. SHOULD THE FABRIC OF A BAFFLE COLLAPSE, TEAR, DECOMPOSE, OR BECOME INEFFECTIVE, REPLACE IT PROMPTLY. REMOVE SEDIMENT DEPOSITS WHEN IT REACHES HALF FULL TO PROVIDE ADEQUATE STORAGE VOLUME FOR THE NEXT RAIN AND TO REDUCE PRESSURE ON THE BAFFLES. TAKE CARE TO AVOID DAMAGING THE BAFFLES DURING CLEANOUT. SEDIMENT DEPTH SHOULD NEVER EXCEED HALF THE DESIGNED STORAGE DEPTH. AFTER THE CONTRIBUTING DRAINAGE AREA HAS BEEN PROPERLY STABILIZED, REMOVE ALL BAFFLE MATERIALS AND UNSTABLE SEDIMENT DEPOSITS, BRING THE AREA TO GRADE, AND STABILIZE IT. POROUS BAFFLES INFLOW STRUCTURE AVERAGE_ Al WIDTH W - L * AREA OF BASIN WATER SURFACE AT TOP OF PRINCIPAL SPILLWAY ELEVATION INFLOW STRUCTURE BAFFLES DEWATERING ' ZONE FILTER FABRIC PLAN VIEW BAFFLES SKIMMER DEWATERING DEVICE w U z a z vi z wa a:2 V)48 48 Q V� 0� Q� H Z C)w �z CD 1 N V) Q zLd m w w 0 w'' w J - - N a - - 0 U w 0 L� EMERGENCY SPILLWAY EMBANKMENT 1' FREEBOARD / 6" MIN. INVE T ELEVATION OF EMERGENCY SPILLWAY EMERGENCY SPILLWAY SEDIMENT STORAGE ZONE CROSS-SECTION VIEW CONSTRUCTION SPECIFICATIONS: 1. CLEAR, GRUB, AND STRIP THE AREA UNDER THE EMBANKMENT OD ALL VEGETATION AND ROOT MATERIAL. REMOVE ALL SURFACE SOIL CONTAINING HIGH AMOUNTS OF ORGANIC MATTER AND STOCKPILE OR DISPOSE OF IT PROPERLY. HAUL ALL OBJECTIONABLE MATERIAL TO THE DESIGNATED DISPOSAL AREA. PLACE TEMPORARY SEDIMENT CONTROL MEASURES BELOW BASIN AS NEEDED. 2. ENSURE THAT FILL MATERIAL FOR THE EMBANKMENT IS FREE OF ROOTS, WOODY VEGETATION, ORGANIC MATTER, AND OTHER OBJECTIONABLE MATERIAL. PLACE THE FILL IN LIFTS NOT TO EXCEED 9 INCHES, AND MACHINE COMPACT IT. OVER FILL THE EMBANKMENT 6 INCHES TO ALLOW FOR SETTLEMENT. 3. SHAPE THE BASIN TO THE SPECIFIED DIMENSIONS. PREVENT THE SKIMMING DEVICE FROM SETTLING INTO THE MUD BY EXCAVATING A SHALLOW PIT UNDER THE SKIMMER OR PROVIDING A LOW SUPPORT UNDER THE SKIMMER OF STONE OR TIMBER. 4. PLACE THE BARREL (TYPICALLY 4-INCH SCHEDULE 40 PVC PIPE) ON A FIRM, SMOOTH FOUNDATION OF IMPERVIOUS SOIL. DO NOT USE PERVIOUS MATERIAL SUCH AS SAND, GRAVEL, OR CRUSHED STONE AS BACKFILL AROUND THE PIPE. PLACE THE FILL MATERIAL AROUND THE PIPE SPILLWAY IN 4-INCH LAYERS AND COMPACT IT UNDER AND AROUND THE PIPE TO AT LEAST THE SAME DENSITY AS THE ADJACENT EMBANKMENT. CARE MUST BE TAKEN TO RAISE THE PIPE FROM THE FIRM CONTACT WITH ITS FOUNDATION WHEN COMPACTING UNDER THE PIPE HAUNCHES. PLACE A MINIMUM DEPTH OF 2 FEET OF COMPACTED BACKFILL OVER THE PIPE SPILLWAY BEFORE CROSSING IT WITH CONSTRUCTION EQUIPMENT. IN NO CASE SHOULD THE PIPE CONDUIT BE INSTALLED BY CUTTING A TRENCH THROUGH THE DAM AFTER THE EMBANKMENT IS COMPLETE. 5. ASSEMBLE THE SKIMMER FOLLOWING THE MANUFACTURERS INSTRUCTIONS, OR AS DESIGNED. 6. LAY THE ASSEMBLED SKIMMER ON THE BOTTOM OF THE BASIN WITH THE FLEXIBLE JOINT AT THE INLET OF THE BARREL PIPE. ATTACH THE FLEXIBLE JOINT TO THE BARREL PIPE AND POSITION THE SKIMMER OVER THE EXCAVATED PIT OR SUPPORT. BE SURE TO ATTACH A ROPE TO THE SKIMMER AND ANCHOR IT TO THE SIDE OF THE BASIN. THIS WILL BE USED TO PULL THE SKIMMER TO THE SIDE FOR MAINTENANCE. 7. EARTHEN SPILLWAYS - INSTALL THE SPILLWAY IN UNDISTURBED SOIL TO THE GREATEST EXTENT POSSIBLE. THE ACHIEVEMENT OF PLANNED ELEVATIONS, GRADE, DESIGN WIDTH, AND ENTRANCE AND EXIT CHANNEL SLOPES ARE CRITICAL TO THE SUCCESSFUL OPERATION OF THE SPILLWAY. THE SPILLWAY SHOULD BE LINED WITH LAMINATED PLASTIC OR IMPERMEABLE GEOTEXTILE FABRIC. THE FABRIC MUST BE WIDE AND LONG ENOUGH TO COVER THE BOTTOM AND SIDES AND EXTEND TO THE TOP OF THE DAM FOR ANCHORING IN A TRENCH. THE EDGES MAY BE SECURED WITH 8-INCH STAPLES OR PINS. THE FABRIC MUST BE LONG ENOUGH TO EXTEND DOWN THE SLOPE AND EXIT ONTO STABLE GROUND. THE WIDTH OF THE FABRIC MUST BE ONE PIECE, NOT JOINED OR SPLICED; OTHERWISE WATER CAN GET UNDER THE FABRIC. IF THE LENGTH OF THE FABRIC IS INSUFFICIENT FOR THE ENTIRE LENGTH OF THE SPILLWAY, MULTIPLE SECTIONS, SPANNING THE COMPLETE WIDTH, MAY BE USED. THE UPPER SECTIONS) SHOULD OVERLAP THE LOWER SECTIONS) SO THAT WATER CANNOT FLOW UNDER THE FABRIC. SECURE THE UPPER EDGE AND SIDES OF THE FABRIC IN A TRENCH WITH STAPLES OR PINS. (ADAPTED FROM "A MANUAL FOR DESIGNING, INSTALLING AND MAINTAINING SKIMMER SEDIMENT BASINS." FEBRUARY, 1999. J.W. FAIRCLOTH & SON). 8. INLETS - DISCHARGE WATER INTO THE BASIN IN A MANNER TO PREVENT EROSION. USE TEMPORARY SLOPE DRAINS OR DIVERSIONS WITH OUTLET PROTECTION TO DIVERT SEDIMENT LADEN WATER TO THE UPPER END OF THE POOL AREA TO IMPROVE BASIN TRAP EFFICIENCY (REFERENCES: RUNOFF CONTROL MEASURES AND OUTLET PROTECTION). 9. EROSION CONTROL - CONSTRUCT THE STRUCTURE SO THAT THE DISTURBED AREA IS MINIMIZED. DIVERT SURFACE WATER AWAY FROM BARE AREAS. COMPLETE THE EMBANKMENT BEFORE AREA IS CLEARED. STABILIZE THE EMERGENCY SPILLWAY EMBANKMENT AND ALL OTHER DISTURBED AREA ABOVE THE CREST OF THE PRINCIPAL SPILLWAY IMMEDIATELY AFTER CONSTRUCTION (REFERENCES: SURFACE AND STABILIZATION). 10. INSTALL POROUS BAFFLES AS SPECIFIED IN PRACTICE 6.65, POROUS BAFFLES. 11. AFTER ALL THE SEDIMENT -PRODUCING AREAS HAVE BEEN PERMANENTLY STABILIZED, REMOVE THE STRUCTURE AND ALL THE INSTABLE SEDIMENT. SMOOTH THE AREA TO BLEND WITH THE ADJOINING AREAS AND STABILIZE PROPERLY (REFERENCES: SURFACE STABILIZATION). MAINTENANCE: INSPECT SKIMMER SEDIMENT BASINS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (ONE-HALH INCH OR GREATER) RAINFALL EVENT AND REPAIR IMMEDIATELY. REMOVE SEDIMENT AND RESTORE THE BASIN TO ITS ORIGINAL DIMENSIONS WHEN SEDIMENT ACCUMULATES TO ONE-HALF THE HEIGHT OF THE FIRST BAFFLE. PULL THE SKIMMER TO ONE SIDE SO THAT THE SEDIMENT UNDERNEATH IT CAN BE EXCAVATED. EXCAVATE THE SEDIMENT FROM THE ENTIRE BASIN, NOT JUST AROUND THE SKIMMER OR THE FIRST CELL. MAKE SURE VEGETATION GROWING IN THE BOTTOM OF THE BASIN DOES NOT HOLD DOWN THE SKIMMER. REPAIR THE BAFFLES IF THEY ARE DAMAGED. RE -ANCHOR THE BAFFLES IF WATER IS FLOWING UNDERNEATH OR AROUND THEM. IF THE SKIMMER IS CLOGGED WITH TRASH AND THERE IS WATER IN THE BASIN, USUALLY JERKING ON THE ROPE WILL MAKE THE SKIMMER BOB UP AND DOWN AND DISLODGE THE DEBRIS AND RESTORE FLOW. IF THIS DOES NOT WORK, PULL THE SKIMMER OVER TO THE SIDE OF THE BASIN AND REMOVE THE DEBRIS. ALSO CHECK THE ORIFICE INSIDE THE SKIMMER TO SEE ID IT IS CLOGGED; IF SO REMOVE THE DEBRIS. IF THE SKIMMER ARM OR BARREL PIPE IS CLOGGED, THE ORIFICE CAN BE REMOVED AND THE OBSTRUCTION CLEARED WITH A PLUMBER'S SNAKE OR BY FLUSHING WITH WATER. BE SURE AND REPLACE THE ORIFICE BEFORE REPOSITIONING THE SKIMMER. CHECK THE FABRIC LINED SPILLWAY FOR DAMAGE AND MAKE ANY REQUIRED REPAIRS WITH FABRIC THAT SPANS THE FULL WIDTH OF THE SPILLWAY. CHECK THE EMBANKMENT, SPILLWAYS, AND OUTLET FOR EROSION DAMAGE, AND INSPECT THE EMBANKMENT FOR PIPING AND SETTLEMENT. MAKE ALL NECESSARY REPAIRS IMMEDIATELY. REMOVE ALL TRASH AND OTHER DEBRIS FROM THE SKIMMER AND POOL AREAS. FREEZING WEATHER CAN RESULT IN ICE FORMING IN THE BASIN. SOME SPECIAL PRECAUTIONS SHOULD BE TAKEN IN THE WINTER TO PREVENT THE SKIMMER FROM PLUGGING WITH ICE. SKIMMER SEDIMENT BASIN ^W W .C71 W Q) U L W E 9° O C N 4_ T L CIO O co LJJ _ 1 C? N O 'tt U �CO �CflO �NLOCO O >, C) CO CIO Z T T N U Cj C: . . a� > Cz Cz x G O N CZ N��LLLLJ d' IIII ,/,/ oC (0 z W d AZ.a z z N :�= J d O �/•� U v0 Y Y Y Y Y m0_ 0_ 0_ 0_ U U U U U L7 z w w w 2 0 O C)O D z U 0U 3: Lu 0 i 0 1 o 0 1 1 w wwocww 0 0_ocw0_0_ rn rn rn rn CD w o 0 0 0 0 N N N N N 0 !�2 2 N 7 o i i O N 0 CD CD r CD � r N m -,I-In DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. D 1 o � � PRELIMINARY SUBDIVISION PLAN :\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D1.3 EC Details, 2/6/2020 8:54:27 AM FANULL IU#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 I U, 1 5y11 / TOP ELEVATION OF STORMWATER — — — — — — — — — — — — — — — — — — — — — — — 1 #57 WASHED DESIGN OF SPILLWAYS sTONE�c DRAINAGE AREA WEIR LENGTH' EXISTING SLOPE (ACRES) (FT) 1 4.0 2 6.0 3 8.0 4 10.0 5 12.0 1DIMENSIONS SHOWN ARE MINIMUM sau CLASS 1 RIP -RAP LTER FABRIC I EXISTING SLOPE �P STEP SEQUENCE FRONT VIEW NOTE: REVISIONS HEIGHT & WIDTH DETERMINED BY EXISTING DATE DESCRIPTION TOPOGRAPHY AND SEDIMENT STORAGE REQUIRED. 10/88 NOTE ADDITION M.H.D. a/ss ADD SPILLWAY CHART G.M.A. KEY RIP RAP INTO THE DAM FOR STABILIZATION. X] IDue] �i11 "NA I STD. No. APRON WIDTH AT THE OUTLET IS 1.5 TIMES THE WIDTH OF THE F.E.S. FLARED END SECTION APRON LENGTH RIP -RAP PLAN VIEW LENGTH OF APRON FLOC SLOPE OF EXISTING L\ SECTION A -A THERE MUST BE NO OVERALL AT THE END OF THE APRON. WHEN THE AREA BELOW THE OUTLET IS NOT A DEFINED CHANNEL, BUILD A FLAT APRON TO DISPERSE RUNOFF. SECTION B-B INSTRUCTIONS FOR RIP RAP APRON / STONE APRON OUTLET PROTECTION FILTER BLANKET INSTALLATION 1. REFER TO THE PLANS FOR LOCATION, EXTENT, AND SPECIFICATIONS. IF THERE ARE QUESTIONS OR PROBLEMS WITH THE LOCATION, EXTENT, OR METHOD OF INSTALLATION, CONTACT THE ENGINEER, ARCHITECT, OR RESPONSIBLE PERSONNEL ON THE SITE FOR ASSISTANCE. EROSION CONTROL PERSONNEL HAVE COPIES OF INSTRUCTIONS AND MAY HAVE PHOTOGRAPHS OR PROPERLY INSTALLED APRONS AS A AID TO INSTALLATION. IF THE STONE APRON IS NOT INSTALLED CORRECTLY THE FIRST TIME, IT WILL HAVE TO BE REBUILT. 2. DETERMINE THE LOCATION ON THE GROUND TAKING INTO CONSIDERATION: * DECIDE HOW EQUIPMENT AND MATERIAL WILL REACH THE LOCATION TO CONSTRUCT THE APRON. DO NOT "PAINT YOURSELF INTO A CORNER" AND PLACE FILL, STRUCTURES, ETC. THAT COULD BLOCK ACCESS. * THE LOCATION OF THE APRON MUST BE SOLID GROUND. IT MAY BE NECESSARY TO EXCAVATE THE LOCATION TO REMOVE MUD AND THEN BACKFILL WITH GOOD MATERIAL. THIS IS NECESSARY SO THE STONE DOES NOT DISAPPEAR INTO THE MUD, WHICH WOULD REQUIRE MUCH MORE STONE TO COMPLETE THE APRON AND MAKE INSTALLATION DIFFICULT. 3. CLEAR THE LOCATION OF THE APRON. LEAVE AS MUCH OF THE EXISTING VEGETATION AS POSSIBLE AROUND THE LOCATION TO HOLD THE SOIL IN PLACE AND REDUCE THE AREA THAT WILL HAVE TO BE STABILIZED AFTERWARD. 4. EXCAVATE THE BOTTOM TO THE REQUIRED DEPTH TO ACCEPT THE STONE AND THE FILTER BLANKET. WHEN FINISHED, THE BOTTOM OF THE APRON MUST BE LEVEL WITH THE BOTTOM OF THE CHANNEL; THERE CANNOT BE AN OVERALL AT THE END OF THE APRON. 5. PLACE THE FILTER BLANKET, AS SPECIFIED IN THE PLAN, OVER THE LOCATION AND UNDER THE LIP OF THE FLARED END SECTION. 6. PLACE THE SPECIFIED STONE TO THE REQUIRED DIMENSIONS AND SHAPE IT TO THE CONFIGURATION SHOWN IN THE PLAN. 7. STABILIZE THE AREA AROUND THE APRON THAT WAS DISTURBED DURING CONSTRUCTION. USE ADDITIONAL STONE OR VEGETATION, WHICHEVER IS APPROPRIATE FOR THE SITUATION. RIP RAP APRON NTS ;OLL OUT STRIPS OF NETTING PARALLEL TO THE DIRECTION OF FLOW AND OVER THE PROTECTIVE MULCH VETTING IN 0�FQ I TRENCH �90 JOIN STRIPS BY ANCHORING AND OVERLAPPING. INSTALLATION OF NETTING AND MATTING PRODUCTS DESIGNED TO CONTROL EROSION SHOULD BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. ANY MAT OR BLANKET -TYPE PRODUCT USED AS A PROTECTIVE MULCH SHOULD PROVIDE COVER OF AT LEAST 30% OF THE SURFACE WHERE IT IS APPLIED. 1. APPLY LIME, FERTILIZER AND SEED BEFORE LAYING THE NET OR MAT. 2. START LAYING THE NET FROM THE TOP OF THE CHANNEL OR SLOPE AND UNROLL IT DOWN THE GRADE. ALLOW NETTING TO LAY LOOSELY ON THE SOIL BUT WITHOUT WRINKLES - DO NOT STRETCH. 3. TO SECURE THE NET, BURY THE UPSLOPE END IN A SLOT OR TRENCH NO LESS THAN 6 INCHES DEEP, COVER WITH SOIL, AND TAMP FIRMLY. STAPLE THE NET EVERY 12 INCHES ACROSS THE TOP END AND EVERY 3 FEET AROUND THE EDGES AND BOTTOM. WHERE 2 STRIPS OF NET ARE LAID SIDE BY SIDE, THE ADJACENT EDGES SHOULD BE OVERLAPPED 3 INCHES AND STAPLED TOGETHER. EACH STRIP OF NETTING SHOULD ALSO BE STAPLED DOWN THE CENTER, EVERY 3 FEET. DO NOT STRETCH THE NET WHEN APPLYING STAPLES. 4. TO JOIN TWO STRIPS, CUT A TRENCH TO ANCHOR THE END OF THE NEW NET. OVERLAP THE END OF THE PREVIOUS ROLL 18 INCHES AND STAPLE EVERY 12 INCHES JUST BELOW THE ANCHOR SLOT. „r_1111 _nLla INSPECT ALL MULCHES PERIODICALLY, AND AFTER RAINSTORMS TO CHECK FOR RILL EROSION, DISLOCATION, OR FAILURE. WHERE EROSION IS OBSERVED, APPLY ADDITIONAL MULCH. IF WASHOUT OCCURS, REPAIR THE SLOPE GRADE, RESEED, AND REINSTALL MULCH. CONTINUE INSPECTIONS UNTIL VEGETATION IS FIRMLY ESTABLISHED. NETS AND MATS PERMANENT SEEDING SCHEDULE: d SEEDING MIXTURE: ° SPECIES RATE (LB/AC) TALL FESCUE 80 SERICEA LESPEDEZA 20 KOBE LESPEDEZA 10 u SEEDING NOTES: 1. AFTER AUGUST 15, USE UN -SCARIFIED SERICEA SEED. 2. WHERE PERIODIC MOWING IS PLANNED OR A NEAT APPEARANCE IS DESIRED, OMIT -L SERICEA AND INCREASE KOBE LESPEDEZA TO 40 LB/ACRE. ^^,, 00 3. TO EXTEND SPRING SEEDING DATES INTO JUNE, ADD 15 LB/ACRE HULLED BERMUDA ^W GRASS. HOWEVER, AFTER MID-APRIL IT IS PREFERABLE TO SEED TEMPORARY W �j COVER. NURSE PLANTS: Q� BETWEEN MAY 1 AND AUG. 15, ADD 10 LB/ACRE GERMAN MILLET OF 15 LB/ACRE SUDAN GRASS. PRIOR TO MAY 1 OR AFTER AUG. 15 ADD 40 LB/ACRE RYE (GRAIN). Lu T 1:t L SEEDING DATES: :t co Cz BEST POSSIBLE O CV LL] FALL: AUG. 25 - SEPT. 15 AUG. 20 - OCT. 25 - Co C� LATE WINTER: FEB. 15 - MAR. 21 FEB. 1 - APR. 15 �OCflC) U FALL IS BEST FOR TALL FESCUE AND LATE WINTER FOR LESPEDEZAS. (n CV Lo Co O �' U Y SOIL AMENDMENTS: ao 0')Cu C'� z T T APPLY LIME AND FERTILIZER ACCORDING TO SOIL TESTS, OR APPLY 4,000 LB/ACRE (.0 U GROUND AGRICULTURAL LIMESTONE AND 1,000 LB/ACRE 10-10-10 FERTILIZER, EXCEPT, APPLY NO FERTILIZER TO AREAS WITHIN THE NEUSE RIVER RIPARIAN BUFFERS. L a)> CZ CZ MULCH: c APPLY 4,000 LB/ACRE GRAIN STRAW OR EQUIVALENT COVER OF ANOTHER SUITABLE 1 1 1 ui ci O CZMULCH. N 0- LL W ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR ROVING OR BY _j CRIMPING WITH A MULCH ANCHORING TOOL. A DISK WITH BLADES NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. TEMPORARY SEEDING SCHEDULES TABLE 6-10A: TEMPORARY SEEDING RECOMMENDATIONS FOR LATE WINTER AND EARLY SPRING SEEDING MIXTURE SPECIES RATE (LB/ACRE) RYE (GRAIN) 120 ANNUAL LESPEDEZA (KOBE IN PIEDMONT AND COASTAL PLAIN, KOREAN IN MOUNTAINS) 50 OMIT ANNUAL LESPEDEZA WHEN DURATION OF TEMPORARY COVER IS NOT TO EXTEND BEYOND JUNE. SEEDING DATES MOUNTAINS - ABOVE 2500 FT: FEB. 15 - MAY 15 BELOW 2500 FT: FEB. 1 - MAY 1 PIEDMONT - JAN. 1 - MAY 1 COASTAL PLAIN - DEC. 1 - APR. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE RE -FERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, RE -FERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. TABLE 6.10B TEMPORARY SEEDING RECOMMENDATIONS FOR SUMMER SEEDING MIXTURE SPECIES RATE (LB/ACRE) GERMAN MILLET 40 IN THE PIEDMONT AND MOUNTAINS, A SMALL -STEMMED SUDAN GRASS MAY BE SUBSTITUTED AT A RATE OF 50 LB/ACRE. SEEDING DATES MOUNTAINS - MAY 15 - AUG.15 PIEDMONT - MAY 1 - AUG.15 COASTAL PLAIN - APR. 15 - AUG. 15 SOIL AMENDMENTS FOLLOW RECOMMENDATIONS OF SOIL TESTS OR APPLY 2,000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 750 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE RE -FERTILIZE IF GROWTH IS NOT FULLY ADEQUATE. RESEED, RE -FERTILIZE AND MULCH IMMEDIATELY FOLLOWING EROSION OR OTHER DAMAGE. TABLE 6.10C TEMPORARY SEEDING RECOMMENDATIONS FOR FALL SEEDING MIXTURE SPECIES RATE (LB/ACRE) RYE (GRAIN) 120 SEEDING DATES MOUNTAINS - AUG. 15 - DEC 15 COASTAL PLAIN AND PIEDMONT - AUG. 15- DEC. 30 SOIL AMENDMENTS FOLLOW SOIL TESTS OR APPLY 2.000 LB/ACRE GROUND AGRICULTURAL LIMESTONE AND 1.000 LB/ACRE 10-10-10 FERTILIZER. MULCH APPLY 4,000 LB/ACRE STRAW. ANCHOR STRAW BY TACKING WITH ASPHALT, NETTING, OR A MULCH ANCHORING TOOL. A DISK WITH BLADES SET NEARLY STRAIGHT CAN BE USED AS A MULCH ANCHORING TOOL. MAINTENANCE REPAIR AND RE -FERTILIZE DAMAGED AREAS IMMEDIATELY. TOP -DRESS WITH 50 LB/ACRE OF NITROGEN IN MARCH. IF IT IS NECESSARY TO EXTEND TEMPORARY COVER BEYOND JUNE 15, OVER -SEED WITH 50 LB/ACRE KOBE (PIEDMONT AND COASTAL PLAIN) OR KOREAN (MOUNTAINS) LESPEDEZA IN LATE FEBRUARY OR EARLY MARCH. STABILIZATION TIME TABLE SITE AREA DESCRIPTION STABILIZATION PERIMETER DIKES, SWALES, DITCHES 7 DAYS AND SLOPES HIGH QUALITY WATER (HWQ) ZONES 7 DAYS SLOPES STEEPER THAN 3:1 7 DAYS SLOPES 3:1 OR FLATTER ALL OTHER AREAS WITH SLOPES THAN 4:1 14 DAYS 14 DAYS TIMEFRAME EXCEPTIONS NONE rol Er IF SLOPES ARE 10' IN LENGTH AND ARE NOT STEEPER THAN 2:1, 14 DAYS ARE ALLOWED 7 DAYS FOR SLOPES > 50' IN LENGTH NONE, EXCEPT FOR FLATTER PERIMETERS & HOW ZONES d- Co Cr (oo w N w C# Z w Z CL wU z a CL = U U Z Ne Iz J CL = a 0 O Cn W �i w w w O 2 2 U O O OU w D Z U O w U w En = w wwocww o w[rwww rn rn rn rn CD w o 0 0 0 N N N N N N Co Co Co N O r f- f- O N 0 CD CD r CD w r N co � U) OC DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. D 1 4 P:\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D1.4 EC Details, 2/6/2020 8:54:32 AM PRELIMINARY SUBDIVISION PLAN F-AKI;tL IU#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / SPIDERS CARRIER PIPE STEEL ENCASEMENT PIPE NOTES: 1. NORMAL SPACING FOR SPIDERS IS 3 PER 18' LENGTH OF PIPE, ONE SUPPORT AT EACH END AND A SUPPORT AT 9' CENTER. 2. ENTIRE SPIDER ASSEMBLY TO BE BITUMINOUS COATED AFTER FABRICATION. 3. FIELD MODIFY AS REQUIRED TO PROVIDE DESIGN SLOPE IN CARRIER PIPE. 4. SIZING TABLE IN P-2.1 6" X 3/8" STEEL PLATE STEEL ENCASEMENT PIPE STAINLESS STEEL SHOES ON EACH FOOT OF SPIDER. CONTINUOUS WELD BOTH SIDE (TYP.) CARRIER PIPE C9 I Q* SEE DETAIL P-2.1 FOR SIZING OF ENCASEMENT PIPES END ELEVATION SIZING TABLE FOR CARRIER PIPES AND CASING PIPES THE FOLLOWING TABLE SUMMARIZES THE REQUIRED SIZES FOR STEEL PIPE ENCASEMENTS: NOTE: NCDOT AND THE RAILROADS MAY HAVE DIFFERENT REQUIREMENTS. STEEL PIPE ENCASEMENT NTS NOMINAL CARRIER PIPE SIZE (INCHES) STEEL CASING PIPE SIZE INCHES RAILROAD CROSSING ROAD CROSSING OUTSIDE DIAMETER WALL THICKNESS OUTSIDE DIAMETER WALL THICKNESS 3 AND UNDER 12.75 0.188 6.625 0.250 4 12.75 0.188 8.625 0.250 6 12.75 0.188 12.75 0.250 8 16 0.219 16 0.250 10 20 0.281 20 0.250 12 24 0.312 24 0.250 14 28 0.375 28 0.312 16 30 0.406 30 0.312 18 36 0.469 36 0.375 20 42 0.562 42 0.500 24 42 0.562 42 0.500 METER BOX FOR 5/8°' AND 3/4" METElRS. s,frrraw cxo P � 1 i 1 , J t -APPROvED By rt �C10 [Y C�FiO] MM.-MR J I _ R 1*1-I ,,s"rlaw AA WATER SYSTEM, INC. Fn z ---I cn Z7 C D CAO 0 N f Z fTl Z � I rn z cn � o V! \ O N � f Z fTl fTl I v 6" MIN. CLASS B CONCRETE / UNDISTURBED EARTH PLAN —BENDS UNDISTURBED EARTH \ TRENCH WIDTH 12" / CLASS B 4S. CONCRETE +� N IT: N BUTTRESS DIMENSIONS PIPE 22 1/2° BENDS 45' BENDS 90' BENDS SIZE L H L H L H 6" 1'-0" 1'-0" 1'-0" 1'-0" 1'-4" 1'-2" 8" 1'-0" 1'-0" 1'-4" 1'-2" 1'-10" 1'-6" 12" 1'-4" 1'-4" 1'-10" 1'-10" 2'-8" 2'-3" :) NOTES: 1. DIMENSION "A" SHOULD BE AS LARGE AS POSSIBLE WITHOUT INTERFERRING WITH THE MECHANICAL JOINT BOLTS 2. THE SHAPE OF THE BACK OF THE BUTTRESS MAY VARY PROVIDED THE CONCRETE IS AGAINST FIRM, UNDISTURDED EARTH. 3. BUTTRESS DIMENSIONS ARE BASED UPON A SOIL RESISTANCE OF TWO TONS PER SQ. FT. AND A WATER PRESSURE OF 150 P.S.I. NOTES: 1. DIMENSION "A" SHOULD BE AS LARGE AS POSSIBLE WITHOUT INTERFERRING WITH THE MECHANICAL JOINT BOLTS 2. THE SHAPE OF THE BACK OF THE BUTTRESS MAY VARY PROVIDED THE CONCRETE IS AGAINST FIRM, UNDISTURDED EARTH. 3. BUTTRESS DIMENSIONS ARE BASED UPON A SOIL RESISTANCE OF TWO TONS PER SQ. FT. AND A WATER PRESSURE OF 150 P.S.I. L z 1/2 L 1/2 L CLASS B < � CONCRETE UNDISTURBED UNDISTURBED EARTH N EARTH \ / y. � q TRENCH WIDTH 12" / � CLASS B � 4g• CONCRETE z p N PLAN —TEE SECTION BUTTRESS DIMENSIONS B. D. L H C D 6" 1'-3" 1'-0" � uj N O � O 8 12" 2'-3" 2'-0" iw z iw z in cn B. D. =BRANCH DIAMETER NOTES: 1. DIMENSION "C" SHOULD BE LARGE ENOUGH TO MAKE ANGLE "A" EQUAL TO OR GREATER THAN 45°. 2. DIMENSION "D" SHOULD BE AS LARGE AS POSSIBLE WITHOUT INTERFERRING WITH EHT MECHANICAL JOINTS. 3. BUTTRESS DIMENSIONS ARE BASED UPON A SOIL RESISTANCE OF TWO TONS PER SQ. FT. AND A WATER PRESSURE OF 150 P.S.I. z �7 (n 2 D o D z N N N � o � D r r � O Z N HYDRANT TEE - W/ 6" BRANCH 3,000 PSI CONCRETE BLOCKING AMERICAN DARLING OR CLOW IF VALVE BOX IS NOT IN PAVED AREA, PROVIDE A 2'-0" X 2'-0" CONCRETE COLLAR (TYP. OF ALL VALVES) 18" MIN. 2» 20" MAX. Ij- CAST IRON J VALVE BOX i 6" GATE VALVE 6" DUCTILE �� ° "�• IRON PIPE ^� 6" DUCTILE SUPPORT VALVE WITH IRON PIPE CONCRETE BLOCKING VARIES VARIES **MEGA -LUG FROM TEE THROUGH VALVE TO HYDRANT CAP RUST-OLEUM OIL BASED BRIGHT WHITE BARRELL RUST-OLEUM OIL BASED TRACTOR RED #57 WASHED STONE BY CONTRACTOR UNDISTURBED EARTH - 3,000 PSI CONCRETE BLOCKING '.•`.�X BOLTS, NUTS AND DRAIN PORTS TO BE FREE OF CONCRETE MINIMUM 6" CONCRETE PLACED UNDER BASE CMU BLOCKS MAY BE USED TO SUPPORT HYDRANT WHILE POURING BLOCKING 4Ld - Lu 00 CZ CZ NO ALTERATIONS NOR ADJUSTMENTS TO BE MADE IN THIS -' ALL WORK IN THIS AREA WITHOUT APPROVAL OF THE UTILITIES ENGINEER. AREA TO BE INSTALLED AS PER 6 4 -5 1'-8 1/2 PLUMBING CODES :z THERE IS > � VARIES IF MBX2 CAST IRON METER BOX I A W/ HOLE IN LID FOR RADIO SIDEWALK � ® READ ANTENNA F00 — ANGLE BALL VALVE NEPTUNE � STD. CURB WITH LOCKING WING RADIO METER CRIMP — PAVEMENT � O w z _ COPPER TAIL z xQ m \ � O 0 z � O o o � vv 00000 000 0000 000000000 V Om SEE NOTE 1 BRICK °o°o°o°o° 000 o°o°o° o°o°o°o°o°o°o°o°o°o B R I C K � Z _ 3/4" TYPE "K" VERTICAL BACK FLOW PREVENTER W/ DUAL � Z n COPPER SERVICE PIPE fTl INLET CHECK VALVE ASSEM. APPROVED Cn � � 3/4" FORD METER SETTER #VBHH72— O A 4" WASHED STONE 82W-44-33G W/ COMPRESSION FITTINGS Z rr, MAIif N ONLY. NO DUEL PURPOSE NUTS. NOTE: 1) COMPRESSION FITTINGS ONLY, NO FLARED FITTINGS. 70 m COMPRESSION NUT DIRECT TAP ALLOWED ON D.I. ONLY. USE FORD DOUBLE _ < FORD 3/4" BRASS CORPORATION COCK STRAP BRASS SADDLE FOR AC AND PVC PIPES. FORD FB-1000-3Q OR APPROVED m � EQUAL. 2) 30" MIN. COVER OVER SERVICE LINES. �Jnnnn nn� � U � o .� o U 'i T � U � N � Co �,l! � N � � p � � U U c� i O ID= Cif E W � N2 0-L.LW W N w� z z� wU Z Q d= U U z� EE J Q_ rt� r O O C/D xj I --I H O � mIUUUUU w w � w � C)O D O Z U� w � � O � w U F--- w cn � 01: co oc o O oc oc w wwocww o wocwww rn rn rn rn o w o 0 0 0 0N N N N cm 0 00 CO CO CO CO O f- f- O N O O O r O W r N C'') � Lo DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc.D 2 0 0 SHEET NO. :\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D2.0 Utility Water Details, 2/6/2020 8:54:37 AM % PRELIMINARY SUBDIVISION PLAN �Jnnnn nn� � U � o .� o U 'i T � U � N � Co �,l! � N � � p � � U U c� i O ID= Cif E W � N2 0-L.LW W N w� z z� wU Z Q d= U U z� EE J Q_ rt� r O O C/D xj I --I H O � mIUUUUU w w � w � C)O D O Z U� w � � O � w U F--- w cn � 01: co oc o O oc oc w wwocww o wocwww rn rn rn rn o w o 0 0 0 0N N N N cm 0 00 CO CO CO CO O f- f- O N O O O r O W r N C'') � Lo DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc.D 2 0 0 SHEET NO. :\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D2.0 Utility Water Details, 2/6/2020 8:54:37 AM % PRELIMINARY SUBDIVISION PLAN W N w� z z� wU Z Q d= U U z� EE J Q_ rt� r O O C/D xj I --I H O � mIUUUUU w w � w � C)O D O Z U� w � � O � w U F--- w cn � 01: co oc o O oc oc w wwocww o wocwww rn rn rn rn o w o 0 0 0 0N N N N cm 0 00 CO CO CO CO O f- f- O N O O O r O W r N C'') � Lo DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc.D 2 0 0 SHEET NO. :\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D2.0 Utility Water Details, 2/6/2020 8:54:37 AM % PRELIMINARY SUBDIVISION PLAN mIUUUUU w w � w � C)O D O Z U� w � � O � w U F--- w cn � 01: co oc o O oc oc w wwocww o wocwww rn rn rn rn o w o 0 0 0 0N N N N cm 0 00 CO CO CO CO O f- f- O N O O O r O W r N C'') � Lo DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc.D 2 0 0 SHEET NO. :\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D2.0 Utility Water Details, 2/6/2020 8:54:37 AM % PRELIMINARY SUBDIVISION PLAN SHEET NO. :\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D2.0 Utility Water Details, 2/6/2020 8:54:37 AM % PRELIMINARY SUBDIVISION PLAN F-AKI;tL IIJ#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / PIPE DIAMETER WALL THICKNESS SLOPE B C D E WEIGHT 12 2 1/4 3:1 24 49 73 24 730 15 2 1/4 3:1 27 46 73 30 910 18 2 1/2 3:1 27 46 73 36 1 190 21 2 3/4 3:1 36 37 73 42 1370 24 3 3:1 42 31 1/2 73 1/2 48 1770 27 3 1/4 3:1 48 25 1/2 73 1/2 54 2130 30 3 1/2 3:1 54 19 3/4 73 3/4 60 2380 36 4 3:1 63 34 3/4 97 3/4 72 5320 42 4 1/2 3:1 63 35 98 78 5920 48 5 3:1 72 26 98 84 7470 54 5 1/2 2.4:1 66 34 100 90 8810 60 6 2:1 60 39 99 96 11180 72 7 2:1 78 21 99 108 13980 DIMENSIONS IN INCHES WEIGHT IN POUNDS FLARED END SECTION -OUTLET DIAMETER X X E D DIAMETER DIAMETER + 1 " SECTION X-X FLARED END SECTION -INLET DIAMETER Z Z E D CB DIAMETER DIAMETER + 1" SECTION Z-Z INLET & OUTLET FLARED END SECTIONS m v NOTES: INSTALL ALL STEPS PROTRUDING 4" FROM INSIDE FACE OF STRUCTURE WALL. z Cn < STEPS DIFFERING IN DIMENSIONS, CONFIGURATION, OR MATERIALS FROM THOSE SHOWN MAY ALSO BE USED PROVIDED THE CONTRACTOR HAS FURNISHED H Q Q F-I Z THE ENGINEER WITH DETAILS OF THE PROPOSED STEPS AND HAS RECEIVED WRITTEN APPROVAL FROM THE ENGINEER FOR THE USE OF SUCH STEPS. D,N.,p� Hp~C0U mz�=D =oZym� Z=-op iH „ 00ro= Lu<zo= = C9 m L~ U�OOQ n=�Z Cno _ CL� Z � r p PLAN SIDE ELEVATION PLAN SIDE ELEVATION - �6 r, NCO Ihr N ;am co or a Z v p W LL N r 1' 1,-6,, 1. 1ai�" .� N a = CAST IRON CAST IRON z O ELEVATION ELEVATION W m � m D C p „ gry"m 1 #6 BAR OR #8 BAR < v I 1/ of GALV'D. N m> T CnUJ Z �a N p PLAN T POLYPROPYLENE ~ Z J ~ m w �B„ Y2 - SIDE PLASTIC ELEVATION PLAN SIDE ELEVATION p w a) COMPOSITE G �nl REINFORCING STEEL ELEVATION #3 DEFORMED NOTE: 12 _ DO NOT USE IN STEEL ROD SECTION A -A SANITARY ELEVATION SEWER MANHOLES. SHEET 1 OF 1 SHEET 1 OF 1 $40.66 840.66 v vm H � H' Z >00p D ri Cp H z � = y GRATE AND FRAME- =C)Zym =Cnoo zH�mm BRICK 0 _ m Z MASONRY D y D WALL Cn 1 H 0 Z ANCHOR GRATE AND FRAME - CONCRETE WALL ANCHOR GRATE AND FRAME BRICK MASONRY CONCRETE CONSTRUCTION CONSTRUCTION DETAIL SHOWING ANCHORAGE OF CU FRAME FOR GRATED DROP INLET `-' z �a Z 0 = cn NOTE: z O = CONSTRUCT GRATED DROP :INLET TO COINCIDE WITH NORMAL v OR SUPERELEVATED SHOULDER OR PAVEMENT SLOPE. O Z m m m O v D v = ifi rr �D 3/8rr DIA. L4" 4„ 0N �8" DIA. 3/8rr _ 3/8rr O DIA. DIA. Z 10 m „ I 10" �2 mv� 1'J/ r I m MASONRY ANCHOR CONCRETE ANCHOR PRECAST 840.25 DIA. BOLT WITH PLATE % DIA. BENT BAR CONCRETE ANCHOR DIA. BENT BAR THREADED ANCHOR -1 " DIA. -APPROVED EPDXY PRECAST CONCRETE WALL PRECAST CONCRETE CONSTRUCTION PRECAST CONCRETE CONSTRUCTION CONCRETE CONSTRUCTION BRICK MASONRY CONSTRUCTION FRAME AND GRATE INSTALLATION FOR NORMAL CROWN AND SUPERELEVATED SECTIONS Z Ov < Q Q HRc CCCC=0 LLJ�I-IZ OOvx Cr z H CnHw0J 00CoQ Z H = 1 (L Q O w x � o N � W U IZID -I U Q LL ►- o Q 0 O w x LL tr o W a O w F- a Lu O = Cr O U JC�U Z Za0 w 1--1 _ m 840.25 v v m Z m Cn 0 0 mm0-1�0 z => =-nZDm =Cno0 m -0 -n HOOD �� � 0 Z w OZ O � Z H O CD N -mN -4 Y m Z c v vn o m o =� v H � m Z z r� m 840.14 v vm H' Z 7C1Npp Dro�1_Cn m142E =� =-nnym -0 _n 2E -0 _n o O 0 = � Z DDD 0) r 0 Z w m z r W � j Cn N N = C7 Cn D = Z 7D v v Gaon oO x v _v N w " Z D -0 F. m M � -n O 840.15 v vm H' Z m Cn 0 r- _n CD mz => =o>>m =cnoo ZI-Iomm �DDD Cn H , 0 _ Z w O x m O m � Z � 0 = Z fn r x v CD v mz D N v 0 m v 4 a D 0 Z z O Z a p v _ x Go 0 N 1 ^." WEEP HOLES I Y ' PLAN WITH GRATE & FRAME REMOVED I I SEE NOTE N L BRICK COPING(INCIDENTAL) TOP ELEVATION - STD. 840.16 FRAME - & GRATE A DOWEL(SEE NOTE) SECTION X-X V 6" GENERAL NOTES: USE CLASS "B" CONCRETE THROUGHOUT. PROVIDE ALL DROP INLETS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. OPTIONAL CONSTRUCTION - MONOLITHIC POUR 2" KEYWAY OR #4 BAR DOWELS AT 12" CENTERS AS DIRECTED BY THE ENGINEER. USE FORMS FOR THE CONSTRUCTION OF THE BOTTOM SLAB. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. CONSTRUCT WITH PIPE CROWNS MATCHING. SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES NOT SHOWN. INSTALL 2" WEEPHOLES AS DIRECTED BY THE ENGINEER. INSTALL STONE DRAINS, OF A MINIMUM OF 1 CUBIC FOOT OF NO. 7BM STONE IN A POROUS FABRIC BAG OR WRAP, AT EACH WEEP HOLE OR AS DIRECTED BY THE ENGINEER. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. a #4 BAR B 6" Cm 6,r 1 DOWEL MAX. PIPE THIS SIDE - 18" SECTION Y-Y DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX & PIPE CUBIC YARDS CONIC. IN BOX DEDUCTIONS FOR ONE PIPE PIPE SPAN WIDTH IMIN. HEIGHT D A B H BOTTOM SLAB WALL PER FT. HT. TOTAL CONCRETE FOR MINIMUM HEIGHT, H C.M. R.C. 12" 3'-0" 2'-0" 2'-0" 0.222 0.222 0.592 0.015 0.026 15" 2'-3" 0.648 0.023 0.036 18" 2'-6" 0.703 0.033 0.049 24" 3'-0" 0.814 0.059 0.085 30" 2'-0" 3'-6" 0.222 0.222 0.925 0.092 1 0.127 I Y PLAN WITH COPING REMOVED SECTION X-X GENERAL NOTES: MORTAR JOINTS It" +/- Lg" THICK. USE CLASS "B" CONCRETE THROUGHOUT. USE FORMS FOR CONSTRUCTION OF THE BOTTOM SLAB. USE #4 BAR DOWELS AT 12" CENTERS. X DEDUCT FOR PIPE(S) FROM TOTAL CU. YDS. OF BRICK MASONRY. - -� PROVIDE ALL CATCH BASINS OVER 3'-6" IN DEPTH WITH STEPS 12" ON CENTER. USE STEPS WHICH COMPLY WITH STD. DRAWING 840.66. USE BRICK OR CONCRETE BLOCK WHICH COMPLIES WITH THE REQUIREMENTS OF SECTION 840 OF THE STANDARD SPECIFICATIONS. IF REINFORCED CONCRETE PIPE IS SET IN BOTTOM SLAB OF BOX, ADD TO SLAB AS SHOWN ON STD. NO. 840.00. FOR 8'-0" IN HEIGHT OR LESS, USE 8" WALL. OVER 8'-0" IN HEIGHT, USE 12" WALL TO 6'-0" FROM TOP OF WALL AND 8" WALL FOR THE REMAINING 6'-0". QUANTITES TO BE ADJUSTED ACCORDINGLY. CONSTRUCT WITH PIPE CROWNS MATCHING. SEE STANDARD DRAWING 840.25 FOR ATTACHMENT OF FRAMES AND GRATES. DO NOT USE BRICK MASONRY DROP INLET IN LOCATIONS SUBJECT TO TRAFFIC. CHAMFER ALL EXPOSED CORNERS 1". DRAWING NOT TO SCALE. uuriNu tINUIUtNIAL) rOP ELEVATION STD. 840.16 RAME AND GRATE v B" B 8" 0 I TE MAX. PIPE THIS SIDE - 1 SECTION Y-Y DIMENSIONS AND QUANTITIES FOR DROP INLET(BASED ON MIN. HEIGHT, H) DIMENSIONS OF BOX & PIPE CUBIC YARDS CONCRETE CUBIC YARDS BRICK MASONRY DEDUCTIONS FOR ONE PIPE PIPE SPAN WIDTH MIN. HEIGHT D A B H BOTTOM SLAB WALL PER FOOT HT. TOTAL BRICK MASONRY FOR MIN. HEIGHT, H C.S. R.C. 12" 3'-0" 2'-0" 2'-0" 0.268 0.313 0.522 0.020 0.032 15" 2'-3" 1 0.268 0.313 0.600 0.031 0.047 18" 2'-6" 1 0.268 0.313 0.678 0.044 0.065 24" 1 3'-0" 1 0.268 0,313 0.835 0.078 0.113 30" 1 3' 0" 2'-0" 3'-6" 1 0.268 1 0.313 1 0.991 0.122 1 0.170 " ESSION SECTION G-G 2'-31/4" 1 %6" 2" SECTION H-H �1 1/2 rr c 1 %2'- Mr\ 15/8,r ��ir5/8rr I r T G 0 0 � - O �o 'N IL► H �\ 41/2 T V-7-5/8" 1'-75/gr' PLAN OF GRATING CAST IRON T #4 BAR N L 6" 3'-611 F-� E E N�------i---- - I I I PLAN OF FRAME CAST IRON Y8 n 1/8" 1/8 rr 1/8rr 1 rr 1 rr 1 rr 1 rr 3'-3-3/4" 2'-33Z4" 118 n 1/8rr 1/8" 1/8 rr 3'-2" 2'_2rr I� FA 21/8rr 21/8r, 3'-13/4'r N N 2r-13/4" N N 3'-6" 2'-6" SECTION E-E SECTION F-F 0 W o J a Z w F-I (L a- CC a 0 O o=cr) �o o � H cn W _ N U) 0 14Z J O z C� w 840.14 Z 0 Cn F_ QQ Hp~C0U LLJrLI-IZ OOC15x C= z w LL Q U cc O o H U) LL 0 J OOUQ Z Hi = 1 ~ CL Q O 1� 840.15 z ov H>_ QQ G4 r-, LLJE"m o0cox x z a"°Co� r- Cnt-wOJ OOCDa Z ,; a: 1 (H 00 Ln T N It Lu ao H o z C3 Q CD � 1-4 0 Q Q o _ co O co o W N s 0 QLLLLo H 0 v W � x J Co N Z m: J m H I --I z a 'S W o � O � x O LL ■ U O U U 'i Q) 0 W T Cz Co N -),l! V I--. NM CItt CU � Comzt r--O 0 Lo Co C) a� a� Y U 00 C0 > _ z T T N a) U 3: Cif CZU i c mzt O X O CZ W _j N�0-LLW CY) W N W C# z z 0- wV Z J r Q = d U ZY_ J d _ Q mIUUUUU �i w w � w 2 z 2 O O 0U w D z U z E75 O z w U w cn c cn oc 0 O oc oc W W W1�1' W W 0 w c w w w m m m m O w o 0 0 o NN N N N N N 0 ,---- ao co Co Co co N 7 O r- r- O N O O O r O > W r N co -,I-Lo DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF Earth Centric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF Earth Centric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 Earth Centric Engineering, Inc. SHEET NO. D 0 :):\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D3.0 SD Details, 2/6/2020 8:54:42 AM SHEET 1 OF 1 840.16 SHEET 1 OF 1 840.16 PRELIMINARY SUBDIVISION PLAN F-AKI;tL ILJ#J 1 7UJU0, 1 7UJU`J, I /U,7I U, 1 5J I 1 4, 15y1 l b, 1 5y11 / CONCRETE PAD FOR CBU (PER USPS) b' MIN TO CBU -CBU LOCATE CBU ONLY 3� (ACCESS FROM PAD) IN CROSSHATCH AREA. (DO NOT INSTALL IN "THROAT" OF CUL-DE-SAC) N5' ADA RAMP LOC. EDGE OF TRAVEL LANE II II ROADWAY CENTERLINE SEE FIGURE 8 PAGE 46, "NCDOT SUBDIVISION ROADS MINIMUM CONSTRUCTION STANDARDS JANUARY 2010" FOR LOCAL AND COLLECTOR ROAD DIMENSIONS. z z g g 6' w w I CBU F- F O O 0 0 0 0 w w 02 CONCRETE PAD FOR CBU NOTE: MAINTAIN R/W OFFSET AROUND CBU PAD FIGURE 4 CBU PLACEMENT FOR SHOULDER SECTION RESIDENTIAL SUBDIVISION STREETS CUL-DE-SAC USPS APPROVED SPECIFICATIONS - CONCRETE PAD (SINGLE UNIT) (All measurements are in inches) 24.0C MIN 2.00- 24.00 MIN 24.00 MIN CBU PEDESTAL 4X 0.50 - ANCHOR BOLTS 4X 4.50 MIN i 4X 4.00 8.00 MIN -*-24.00- MIN 4.00 CBU OUTLINE K08I91 BROOM FINISH 4X 0.50 ANCHOR BOLTS, USE TEMPLATE TO ENSURE ALIGNMENT CHAMFER EDGES, IN LANDSCAPE AREAS, TOOL EDGES FLUSH WITH ADJOINING SURFACES IN PAVED AREAS. 10.00 5.00 T7 _- SLOPE SURFACE 25 INCH PER FOOT ON ALL SIDES FOR DRAINAGE. BUTYL RUBBER PAD (WITH METAL PEDESTAL ONLY) MATCH EXISTING GRADE IN PAVED AREAS SLOPE SURFACE .25 INCH PER FOOT ON ALL SIDES FOR DRAINAGE 4 RODS ON 14.00 CENTERS MAXIMUM, EACH WAY OPTIONAL COMPACT GRAVEL OR CRUSHED STONE (OMIT WHERE SOLID ROCK OCCURS) 8.00 MIN MAXIMUM FROST DEPTH FIRM UNDISTURBED SOIL OR WELL -COMPACTED FILL NOTES: 1. CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 PSI @ 28 DAYS, CONTAIN 4% MIN - 6% MAX AIR ENTRAINMENT AND BE PLACED WITH A 3.50 - 4.50 SLUMP IN ACCORDANCE WITH ACI 301. 2. REINFORCING STEEL RODS SHALL CONFORM TO ASTM A615, GRADE 60. 3. ANCHOR BOLTS SHALL CONFORM TO ASTM A193, GRADE B8M, TYPE 316 STAINLESS STEEL. 15 16 BOX CLUSTER MAILB UNIT, FACED TO TRAFI TYPICAL SIZE SHO (18" DEEP X 30.5" WIC / � /'1 CLUSTER MAIL BOX UNITS 1" - 5' * TERRAIN MAX SLOPE LEVEL 2:1 ROLLING 2:1 HILLY 1-1/2:1 60' R/W 48' SLOPE AS REQUIRED SECTION AA FIGURE 8 (ALTERNATE) SYMMETRICAL CUL-DE-SAC NO CURB & GUTTER FOP 6' 5' 4' E3 VAR. 6.0, 8.0, 5.0' PAVEMENT SHOULDER +3" /FT. WIDTH WIDTH +2" /FT. 1 4" /FT. -1/4" /FT. +1" /FT. -1" /FT. -2 1 /4" /FT. 5.0' DRIVEWAY TURNOUT GRADES SHOULDER SECTION S�OQ� I 60' ROW 6' 26' 6' 5' SHLDR PAVEMENT SHLDR DITC I 0.08 0.02 I 0.02 0.08 3:1 RESIDENTIAL LOCAL ROAD TYPICAL SHOULDER SECTION (ALTERNATE) NTS 2.00" S9.513 * MAX BACKSLOPE: 3:1 SLOPE MAX ALL ROADSIDE DITCHES SHALL BE PROPERLY PROTECTED UNTIL PERMANENT VEGETATION IS ESTABLISHED CSTBC OR ABC 8" ABC OR STBC, TYPE B 3" COMPACTED SUBGRADE - 100% CTANr1APr1 PPnrTnP PAVEMENT SECTION NTS R/W R/W I 60, /W II I 70.0' � I � R3 .0' 26' RAVE. R3 .0' SIGHT TRIANGLE o �(TYP.) R/W=--- ** o L-o ---= R/W 15" DRIVE PIPE EDGE OF PAVEMENT EDGE OF PAVEMENT EXISTING ROAD EDGE OF PAVEMENT EDGE OF PAVEMENT ** NOTE: DRAINAGE EASEMENTS MAY BE REQUIRED TO ACCOMODATE DRAINAGE BEYOND THE RIGHT-OF-WAY. WINDING CREEK TRAIL CONNECTION NTS 50' PRIVATE ROW PATTON MILL LANE CLASS 1 PRIVATE ROAD I ALL DITCHES SHALL BE I I I PROPERLY PROTECTED UNTIL PERMANENT VEGETATION IS 1 12' 1 ESTABLISHED PAVED APRON (SEE DETAIL BELOW) I 0 w I ICS I 70.0' SIGHT TRIANGLE (10'X70' TYP.) R/W 0 20 MIN. - R/W �15" DRIVE PIPE EDGE OF PAVEMENT R20.0' R20.0' EDGE OF PAVEMENT EXISTING ROAD EDGE OF PAVEMENT EDGE OF PAVEMENT NOTE: PERMANENT DRAINAGE EASEMENTS MAY BE REQUIRED TO ACCOMODATE DRAINAGE BEYOND THE RIGHT-OF-WAY. S�OQE 7' SHLDR_ DLH R 8% 2" SF 9. VAR. - 20' 7' 5' SHLDR DITC 8% 3:1 \_8" COMPACTED AGGREGATE BASE COURSE PATTON MILL LANE CONNECTION NTS III C� U � � O �o o O U 0 W r � i (13 U �NM��j O C9 0 U �C\JLoCo O C) a� a� Y Uao CoZ > T T N m U a)��� > Cz CZ L CZU � U -0CC � o x G O CU i CZ W _j CV 0- LL W IY CD W N W C# Z W Z0- WV z J Q = 2 U o Z_y EE J a- = F1 rt� r O N ^W h--I O W I� mIIL IL IL IL 0- UUUUU L7 Z W LU LU 2 2 2 O O U O D Z U 3 Lu or- O or-w U Lu c� 0:: co or- o O or- oc o D_ or_ LU D_ D_ rn M M M CD Lu o 0 0 08 N N N N N a0 2 N 7 O 0 CD CD 0 CD � r N M " Ln DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. D400 PRELIMINARY SUBDIVISION PLAN :\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D4.0 Site Details, 2/6/2020 8:54:47 AM FAKI;tL IU#J I /UJU0, I /UJU'J, I /U,S I U, 1 5y I 1 4, 15y1 1 b, 1 5y11 / El N 0 TRAIL VoO CONCRETE PAD FOR HANDICAP PARKING & ISLE 2% MAXIMUM SURFACE SLOPE IN ANY DIRECTION ACROSS CONCRETE SECTION �Z O f� ff. \ `Po \ G y o-sue � o J "9Q 9� 0 Q o- f� 0 \ C f� PREP Q PR�� sl 60P f� TYPICAL 4" WIDE AINTED LINES (WHITE) g0 7� a \ 0 \ OL FO C� i0 a � . 9° TRAIL DESIGN AND HANDICAP VAN CONSTRUCTION BY ACCESSIBLE SIGN ALAMANCE PARKS, TRAILS & OPEN FUTURE TRAIL PARKING DETAIL SPACE COORDINATOR C = 109 12" VAN Err ADD THIS SIGN [ACCESSIBLE ONLY AT 12" DESIGNATED "VAN" SPACES RESERVED SIGNAGE PANEL PARKING (SEE OPTIONS TO THE RIGHT) 18" z m CENTER R7-8C i HANDICAP SIGN a_o SIGNAGE AT V) 0- HEAD OF EACH R7-a. w V) 0 SPACE R7-8D cn 12 SIGN m THIS PANEL FOR MAXIMUM a HANDICAP v Z 00 SIGNS ONLY PENALTY 9" z 0 J 1-1/4"X 1-1/4'r $250 zm 0 �_ o ALUMINUM TUBE ALUMINUM SIGN - PANEL (TYP.) 0 `n STEEL TROWEL z o FINISH _ FINISHED GRADE 0 4'• :a ALL STEEL FASTENERS SHALL BE GALVANIZED I I 8rr 1 DIiA. PARKING SIGNAGE DETAILS N TS nnnn nn� U o 'i Cv 0 W T qti Cif U � cm � M M U � C/)C\JLoCo O U10Co Co � _ z T T N U a���e aj CZ U c :t O X � O N i Cz W 0 CV LL W ,It cc:(o W N W C# Z W Z CL wV z ¢' — U U Z v EE J CL = E-� 9k fi ou mIUUUUU �i w w w 2 2 O U O O OU w D Z U d:�O0[:w U � w c75 � [r co Cr o O Cr Cr w wwoCww o wocwww m m m m CD w o 0 0 0 0 N N N N N � r- N CD O _ f- r— f- O � N O O O r O w r N co � Lo DATE: AUGUST 29, 2018 HORIZONTAL SCALE: N/A VERTICAL SCALE: N/A PROJECT MANAGER: CPK DRAWN BY: SCS PROJECT NO: 17-002 DRAWING NAME: 17-002 DETAILS THIS DRAWING AND THE DESIGN HEREON ARE THE PROPERTY OF EarthCentric Engineering, Inc. THE INFORMATION ON THIS DRAWING IS NOT FOR USE ON ANY OTHER SITE OR PROJECT. THE REPRODUCTION OR OTHER USE OF THIS DRAWING IN WHOLE OR IN PART, WITHOUT WRITTEN CONSENT OF EarthCentric Engineering, Inc., IS PROHIBITED. COPYRIGHT 2020 EarthCentric Engineering, Inc. SHEET NO. D 4 o P:\17-002\17-002 Drawings\7. Rev05\17-002 Details.dwg, D4.1 Trail Details, 2/6/2020 8:54:52 AM PRELIMINARY SUBDIVISION PLAN