Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
NC0039152_Renewal (Application)_20200206
4 le.d'a.�w.Y� :fi t ROY COOPER It [Y Governor 4,3 - _;fe`; ' z MICHAEL S.REGAN ^'* au.M " Secretary ,n-,�,o S.DANIEL SMITH NORTH CAROLINA Director Environmental Quality February 07, 2020 Ohio Electric Motors Inc. Attn: Katie Grow, General Manager 30 Paint Fork Rd Barnardsville, NC 28709 Subject: Permit Renewal Application No. NC0039152 Ohio Electric Motors WWTP Buncombe County Dear Applicant: The Water Quality Permitting Section acknowledges the February 6, 2020 receipt of your permit renewal application and supporting documentation. Your application will be assigned to a permit writer within the Section's NPDES WW permitting branch. Per G.S. 150B-3 your current permit does not expire until permit decision on the application is made. Continuation of the current permit is contingent on timely and sufficient application for renewal of the current permit. The permit writer will contact you if additional information is required to complete your permit renewal. Please respond in a timely manner to requests for additional information necessary to allow a complete review of the application and renewal of the permit. Information regarding the status of your renewal application can be found online using the Department of Environmental Quality's Environmental Application Tracker at: https://deq.nc.gov/permits-regulations/permit-guidance/environmental-application-tracker If you have any additional questions about the permit, please contact the primary reviewer of the application using the links available within the Application Tracker. Sincerely SitifitC103 Wren Thedford Administrative Assistant Water Quality Permitting Section cc: Central Files w/application ec: WQPS Laserfiche File w/application DE ' ) \ North Caro iha Department of Ervironrnental QQualAy I Divs'on of Water Resot;rcas Ahev;i:e Rega�ral>}ffio- 2{]9D U.S.7D}th�va_ I Sv:annanpe North Ca ro ira 2$778 i::.= o.�„ 828-2fiB-45{J0 NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. Mail the complete application to: N. C. DENR / Division of Water Quality / NPDES Unit 1617 Mail Service Center, Raleigh, NC 27699-1617 NPDES Permit Number NC0039152 Please print or type. 1. Contact Information: Owner Name Katie Grow, General Manager Facility Name Ohio Electric Motors, Inc. -C CI /F Mailing Address 30 Paint Fork Rd City Barnardsville FEB 6 2020 State / Zip Code North Carolina / 28709 NCDEQIDWRINPUES Telephone Number (828) 626-2901 Fax Number ; (828) 626-2155 e-mail Address meatmon@ohioelectricmotors.com 2. Location of facility producing discharge: Check here if same as above El Street Address or State Road City State / Zip Code County 3. Operator Information: Name of the firm, consultant or other entity that operates the facility. (Note that this is not referring to the Operator in Responsible Charge or ORC) Name Ohio Electric Motors, Inc. Mailing Address 30 Paint Fork Rd City Barnardsville State / Zip Code North Carolina / 28709 Telephone Number (828) 626-2901 Fax Number (828) 626-2155 4. Ownership Status: Federal ❑ State ❑ Private ® Public ❑ Page 1 of 5 C-MI 10/08 NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. 5. Standard Industrial Classification (SIC) code(s): 3621 6. Number of employees: 72 7. Describe the treatment system List all installed waste treatment components with capacities, describe the processes that generate wastewaters. If the space provided is not sufficient attach a separate sheet of paper with the system description. Outfall 001: Septic System - Waste water system consists of a 0.0025MGD Domestic Waste Treatment System with the following components. Two Tanks, Subsurface Sand Filter, and Tablet Chlorination System followed by a De-Chlorination System. This rarely discharges, usually in times of high rainfall, and is closely monitored and analyzed per permit requirements. This outfall discharges into Paint Fork Creek. Outfall 002: Cooling Water Discharge - This discharge is clean water only that has been used for circulation through machine cooling systems. Nothing is added or required to be removed from this discharge. Monitoring consists of checking temperature and pH levels as required by permit. 8. Is facility covered under federal effluent limitation guidelines? No ® Yes ❑ If yes, specify the category? 9. Principal product(s) produced: Electric Motors Principal raw material(s) consumed: N/A Briefly describe the manufacturing process(es): End covers, shells, and shafts are machined. Shafts are stacked with steel laminations and insulation epoxy applied. This core is then assembled as an armature by winding magnet wire into the slots, connecting the wires to the comm, fusing the wires to the comm, and applying varnish. The covers and shells are processed into subassemblies and all components are assembled as a complete motor. The manufacturing process produces no discharged waste. Page 2 of 5 C-MI 10/08 NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. 10. Amount of principal product produced or raw material consumed (List specific amounts consumed and/or units of production over the last three years) Product Produced or Raw Material Product Produced or Raw Material Consumed Consumed (AVERAGE) (PEAK) per Day 180 Motors Produced 300 Motors per Month 3,520 Motors Produced 4,000 Motors per Year 42,240 Motors Produced 45,000 Motors 11. Frequency of discharge: Continuous ❑ Intermittent If intermittent: Days per week discharge occurs: 7 Duration: OUTFALL 001 - Occasional OUTFALL 002 - 10 hrs per day 12. Types of wastewater discharged to surface waters only Flow Discharge (GALLONS PER DAY) Sanitary - monthly average <1 gallons per day average - Outfall 1 Utility water, etc. - monthly average 4,000 gallons per day- Outfall 2 Process water - monthly average 0 Stormwater-monthly average 0 Other-monthly average Explain: 0 Monthly Average 4,001 Gallons per day total total discharge (all types) 13. Number of separate discharge points: 2 Outfall Identification number(s) 001 & 002 14. Name of receiving stream(s) (Provide a map showing the exact location of each outfall, including latitude and longitude): Paint Fork Creek in the French Broad River Basin Map Attached. Page 3 of 5 C-MI 10/08 NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. 15. Effluent Data [for new or proposed discharges] Provide data for the parameters listed. Temperature and pH shall be grab samples,for all other parameters 24-hour composite sampling shall be used. If more than one analysis is reported, report daily maximum and monthly average. If only one analysis is reported, report as daily maximum. NOTE:Permittees requesting renewal should complete the table ONLY for the parameters currently monitored. Summarize the past 3 years of effluent data. Parameter Daily Monthly Units of Maximum Average Measurement Biochemical Oxygen Demand (BOD5) 12.5 4.02 Mg/L Chemical Oxygen Demand (COD) Total Organic Carbon Total Suspended Solids 62.3 4.7 mg/L Ammonia as N 1.7 0.4 mg/L Temperature (Summer) 22.8 20.2 Celsius Temperature (Winter) 15.3 11.2 Celsius pH 8.6 6.5 pH Fecal Coliform (If sanitary waste is 1 1 ug/L present) Total Residual Chlorine (if chlorine is 34 13.5 ug/L used) 16. List all permits, construction approvals and/or applications (check all that apply and provide permit numbers or check none if not applicable): Type Permit Number Type Permit Number Hazardous Waste (RCRA) NESHAPS (CAA) UIC (SDWA) Ocean Dumping (MPRSA) NPDES NC0039 152 Dredge or fill (Section 404 or CWA) PSD (CAA) Other 11-757-10 Air Quality Non-attainment program (CAA) NC0111460 Drinking 17. List any chemicals that may be discharged (Please list and explain source and potential amounts.) Page 4 of 5 C-MI 10/08 NPDES PERMIT APPLICATION - SHORT FORM C - Minor Industrial Minor industrial, manufacturing and commercial facilities. 18. Is this facility located on Indian country? (check one) Yes ❑ No El 19. Applicant Certification I certify that I am familiar with the information contained in the application and that to the best of my knowledge and belief such information is true, complete, and accurate. 14 c n o p-ow P L-A-crc MA,NA& Printed name of Person Signing Title \ U2�oy- j2o?a Signa ure f plicantC-C-;) Date North Carolina General Statute 143-215.6 (b)(2) provides that: Any person who knowingly makes any false statement representation, or certification in any application, record, report, plan, or other document files or required to be maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, or who falsifies, tampers with, or knowingly renders inaccurate any recording or monitoring device or method required to be operated or maintained under Article 21 or regulations of the Environmental Management Commission implementing that Article, shall be guilty of a misdemeanor punishable by a fine not to exceed $25,000, or by imprisonment not to exceed six months, or by both. (18 U.S.C. Section 1001 provides a punishment by a fine of not more than$25,000 or imprisonment not more than 5 years, or both, for a similar offense.) Page 5 of 5 C-MI 10/08 ,-.•- . 4,..."*.":" • .-11.11 __ .....-,---..---,.„ .,., - - _ / < . -- _______- _ • Ohio Electric Motors , ./,,, _ _ .. . Legend 7/ l'ir .H. -- Ira 7 30 Paint Fork Rd Sight Overview and Outfall Locations for Waste Water Discharge - --.7.''': Latitude: 35*46152" — -...... , , \ Longitude: 82*2730" l ......-....., t-,... . , —.._, - - ..s. , , A -if- 4r :, ,. ,. '.- , , -_- - • '' ' ' .., -- ' 1-,c„ , :,,,,,,,..-- ,t.,. • - ,'„i., :: ; ..-t - -- - ,..,: , 'A' ‘' .. .. . , 4 ,.. t tre ,.- Tr %if : _•=.; . ..%-.--. . , ,.......,,,, , . . - .,, :,:, i z-,-,.?t...•., ,,.. , 3 . . ' • 1003 "" . .-. • - - 1 ,/,‘ 4.--i* Ak -- . , j-- .;••,:,*i; ,, .. ... ; f.tc4V2,-( , ,1 , „-,%' /7\ • , . \ V ,\\ -. . .. -... i'...- ...74*-'1:*'747.,!•'. 4'''',','4'..;..%.44#4-9.i'Y'''71 4 '',4.': "v `„_7.,77 • -."7-1.' ' 1, ., ,..i.ry . ....tv- ..gt.:i ... P ' '‘.....;.•.::47,Pral . ' P-:''',. 4,.../Vk4. !,./..1/47'1'- ,f":-..6..,/ . 1. . . '''' q f .4..'•' ';'RAT: ;;..g.1 ',..e.:::r7' • c- ,r, ft' '• • .' ' ',O\ SAV- -% .1' ,41 ,`',." '.'',\0 • ., ii..4, •4. "I-*.:i0' ____, "'—'; / /-=.=-* , e...11;,:-...'k,' . ':t's *4• . . .. , . , . - \,-,' ,' ' ,\ t'.i 4.• 4 ' a, , . . ._ .,. \ , \\ - • ..- * , \ - ki: 4), • • \ ., '4 1 '<c • / • \ . .4 \ - , • . - / .\ \ v\ • , , , s-•,;*"..it 1 '--..,-,.- .., .. I ‘,\.•. . . "‘i• V , , • , , , • .''''-9 . . , .., . . ,-..., ./ . Paint Fork Rd , • 1 4 - e" Ear . • , ,.. ,,,,.... . Mt -' --"-- . , 40oei...-..,,- . • • s, \t . ©20., . . .. .. 300 ft