Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
310854_compliance-complaint_20200114
O Division of Water Resources / Facility Number - ® O Division of Soil and Water Conservation v O Other Agency Type of Visit: lD'Compliance Inspect' O Operation Review O Structure Evaluation O Technical Assistance Reason for Visit: O Routine omplaint O Follow-up O Referral O Emergency O Other 0 Denied Access Date of Visit: Arrival Time: Departure Time: County: Farm Name: (� /�0 ((Q, y Owner Email: Owner Name: cy�rz �a"C «� Phone: Mailing Address: Physical Address: Facility Contact: Onsite Representative: Certified Operator: Back-up Operator: Location of Farm: Design Current Swine Capacity Pop. Wean to Finish Wean to Feeder Feeder to Finish Farrow to Wean Farrow to Feeder Farrow to Finish Gilts Boars Other Other Title: Latitude: • t �i Region: Phone: Integrator: Certification Number: Certification Number: Longitude: Design Current Wet Poultry Capacity Pop. Rlon-Layer ayerI I Ed Design Current Dry Poultry Canacitv POD. Layers Non -Layers Pullets Turkeys Turkey Poults Other Design Current Cattle Capacity Pop. Dairy Cow Dairy Calf Dairy Heifer Dry Cow Non -Dairy Beef Stocker Beef Feeder Beef Brood Cow Discharges and Stream Impacts 1. Is any discharge observed from any part of the operation? es ❑ No ❑ NA ❑ NE Discharge originated at: ❑ Structure ❑ Application Field Other: �A C 4, � a. Was the conveyance man-made?"U?�e�s ❑ No ❑ NA ❑ NE b. Did the discharge reach waters of the State? (If yes, notify DWR) �es ❑ No ❑ NA ❑ NE c. What is the estimated volume that reached waters of the State (gallons)? / 9D d. Does the discharge bypass the waste management system? (If yes, notify DWR) es ❑ No ❑ NA ❑ NE 2. Is there evidence of a past discharge from any part of the operation? [2-Y 'es ❑ No ❑ NA ❑ NE 3. Were there any observable adverse impacts or potential adverse impacts to the waters ❑ Yes ® ❑ NA ❑ NE of the State other than from a discharge? Page 1 of 3 21412015 Continued Facility Number: - y, 9 Date of Inspection: Waste Collection & Treatment 4. Is storage capacity (structural plus storm storage plus heavy rainfall) less than adequate? es ❑ No ❑ NA ❑ NE a. If yes, is waste level into the structural freeboard? C?� 171dJZ9,(_ ❑ Yes [ ]�o ❑ NA ❑ NE Structure 1 Structure 2 Structure 3 Structure 4 Structure 5 Structure 6 Identifier: Spillway?: Designed Freeboard (in): Observed Freeboard (in): 5. Are there any immediate threats to the integrity of any of the structures observed? ❑ Yes ®'< ❑ NA ❑ NE (i.e., large trees, severe erosion, seepage, etc.) 6. Are there structures on -site which are not properly addressed and/or managed through a ❑ Yes Flo ❑ NA ❑ NE waste management or closure plan? If any of questions 4-6 were answered yes, and the situation poses an immediate public health or environmental threat, notify DWR 7. Do any of the structures need maintenance or improvement? es ❑ No ❑ NA ❑ NE 8. Do any of the structures lack adequate markers as required by the permit? ❑ Yes FU ❑ NA ❑ NE (not applicable to roofed pits, dry stacks, and/or wet stacks) 9. Does any part of the waste management system other than the waste structures require n/ ❑ No ❑ NA ❑ NE maintenance or improvement? Waste Application 10. Are there any required buffers, setbacks, or compliance alternatives that need ❑ Yes ❑ No ❑ NA maintenance or improvement? 11. Is there evidence of incorrect land application? If yes, check the appropriate box below. ❑ Yes ❑ No ❑ NA �E ❑ Excessive Ponding ❑ Hydraulic Overload ❑ Frozen Ground ❑ Heavy Metals (Cu, Zn, etc.) ❑ PAN ❑ PAN > 10% or 10 lbs. ❑ Total Phosphorus ❑ Failure to Incorporate Manure/Sludge into Bare Soil ❑ Outside of Acceptable Crop Window ❑ Evidence of Wind Drift ❑ Application Outside of Approved Area 12. Crop Type(s): 13. Soil Type(s): 14. Do the receiving crops differ from those designated in the CAWMP? ❑ Yes ❑ No ❑ NA 15. Does the receiving crop and/or land application site need improvement? ❑ Yes ❑ No ❑ NA ©-<E 16. Did the facility fail to secure and/or operate per the irrigation design or wettable ❑ Yes ❑ No ❑ NA ©-NE acres determination? 17. Does the facility lack adequate acreage for land application? ❑ Yes ❑ No ❑ NA ©CIE 18. Is there a lack of properly operating waste application equipment? ❑ Yes ❑ No ❑ NA [JNE Required Records & Documents 19. Did the facility fail to have the Certificate of Coverage & Permit readily available? ❑ Yes ❑ No ❑ NA ®'1qf 20. Does the facility fail to have all components of the CAWMP readily available? If yes, check ❑ Yes ❑ No ❑ NA Q the appropriate box. ❑ WUP ❑ Checklists ❑ Design ❑ Maps ❑ Lease Agreements ❑ Other: 21. Does record keeping need improvement? If yes, check the appropriate box below. ❑ Yes ❑ No ❑ Waste Application ❑ Weekly Freeboard ❑ Waste Analysis ❑ Soil Analysis ❑ Waste Transfers ❑ Rainfall ❑ Stocking ❑ Crop Yield ❑ 120 Minute Inspections ❑ Monthly and 1" Rainfall Inspections 22. Did the facility fail to install and maintain a rain gauge? ❑ Yes ❑ No 23. If selected, did the facility fail to install and maintain rainbreakers on irrigation equipment? ❑ Yes ❑ No ❑ NA I✓- E ❑ Weather Code ❑ Sludge Survey ❑ NA E 1VE ❑ NA Egl< Page 2 of 3 21412015 Continued Facility Number: c - Date of Ins ection: d� 24. Did the facility fail to calibrate waste application equipment as required by the permit? ❑ Yes ❑ No ❑ NA fE 25. Is the facility out of compliance with permit conditions related to sludge? If yes, check ❑ Yes ❑ No ❑ NA ED-TM the appropriate box(es) below. ❑ Failure to complete annual sludge survey ❑ Failure to develop a POA for sludge levels ❑ Non -compliant sludge levels in any lagoon List structure(s) and date of first survey indicating non-compliance: 26. Did the facility fail provide documentation of an actively certified operator in charge? ❑ Yes ❑ No ❑ NA ❑E 27. Did the facility fail to secure a phosphorus loss assessments (PLAT) certification? ❑ Yes ❑ No ❑ NA j]-N9 Other Issues 28. Did the facility fail to properly dispose of dead animals with 24 hours and/or document ❑ Yes ❑ No ❑ NA and report mortality rates that were higher than normal? 29. At the time of the inspection did the facility pose an odor or air quality concern? ❑ Yes ❑ No ❑ NA 8lE If yes, contact a regional Air Quality representative immediately. 30. Did the facility fail to notify the Regional Office of emergency situations as required by the ❑ Yes ❑ No ❑ NA permit? (i.e., discharge, freeboard problems, over -application) 31. Do subsurface tile drains exist at the facility? If yes, check the appropriate box below. ❑ Yes ❑ No ❑ NA E3<E ❑ Application Field ❑ Lagoon/Storage Pond ❑ Other: 32. Were any additional problems noted which cause non-compliance of the permit or CAWMP? ❑ Yes ❑ No ❑ NA �NE 33. Did the Reviewer/Inspector fail to discuss review/inspection with an on -site representative? ❑ Yes ❑ No ❑ NA J:�INE 34. Does the facility require a follow-up visit by the same agency? ❑ Yes ❑ No ❑ NA &"_ Comments (refer to question #): Explain any YES answers and/or any additional recommendations or any other comments. Use drawings of facility to better explain situations (use additional pages as necessary). 54,6, POA r .� � � �(��/j !— .(�(� ,� / JVl V � v C.�/ �rvi%/i�� ✓ , `< <-C OW.�`_ �i� lL `7�/T'/a..�%�r. l f � (/ 41AA1 �c �i�f s ��r� �`�-i Maus 40ow ly�5A 0 " ru 7� �� �c G j /��✓ice �r o�� a c/�'� f c.,� ca P n/A, ✓tee v 1�Uv� �<d ✓JU/ CO (Jt-7C� � � �LO''1 �l' O (YG�-J�,9�- Y CLe2lr?dJ�-C.�l Reviewer/Inspector Name: Reviewer/Inspector Signature: Phone: 9/0 2q� 7.� 72 Date: �� Page 3 of 3 21412015