HomeMy WebLinkAboutWQ0015052_Inspection_20171109Compliance Inspection Report
Permit: WQ0015052 Effective: 03/20/09 Expiration: 02/28/18 Owner: Enviro-Tech of North Carolina Inc
SOC: Effective: Expiration: Facility: Village at Ocean Hill WWTP
County: Currituck 1298 Ponton Ln
Region: Washington
Harbinger NC 279410069
Contact Person: William Galen Freed Title: President Phone: 252-491-5277
Directions to Facility:
US-264E to NC 32 in Pantego, NC 32 to Plymouth, US 64 to Kitty Hawk, Follow NC 12 to Corolla, R onto 1493, Continue onto Ocean
Blvd, Continue onto NC 12/Duck Rd, to Ocean Trail, L onto Ponton Lane, R to stay on Ponton Lane, turn R, destination on R
System Classifications: SI, WW2,
Primary ORC: James Keith Bliven Certification: 28243 Phone: 252-491-5277
Secondary ORC(s):
On -Site Representative(s):
Related Permits:
Inspection Date: 11/09/2017 EntryTime: 10:OOAM
Primary Inspector: Sarah A Toppen
Secondary Inspector(s):
Robert B Tankard
Reason for Inspection: Routine
Permit Inspection Type: Reclaimed Water
Facility Status: ❑ Compliant 0 Not Compliant
Question Areas:
Exit Time: 12:15PM
Phone: 252-946-6481
Phone :252-946-6481 Ext.233
Inspection Type: Compliance Evaluation
■ Treatment Flow Measurement -Effluent . Treatment Flow Measurement -Influent
Treatment Flow Measurement -Water Treatment
Use Records
Treatment Filters Record Keeping
■ Treatment Sludge Storage/Treatment Treatment Clarifiers
End Use -Infiltration Treatment Flow Measurement
Standby Power Wells
(See attachment summary)
■ Miscellaneous Questions
■ Treatment Barscreen
Treatment Activated Sludge
Treatment Disinfection
Treatment Return pumps
Page 1 of 7
Permit: W00015052 Owner - Facility: Enviro-Tech of North Carolina Inc
Inspection Date: 11/09/2017 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Inspection Summary
On Thursday, November 9, 2017 Robert Tankard and Sarah Toppen (NCDEQ-DWR) conducted an compliance inspection
with the ORC, Jimmy Bliven (ORC) was present.
When we first arrived on -site we noticed the fence doesn't cover the perimater of the wastewater treatment facility. There has
been alot of encroachment onto the property. A camper trailer is located adjacent to the plant and a plant nursery is also
adjacent to the plant.
The transfer switch on the generator is broken. The generator failed to start when the power was interrupted. The generator
startee manually. The generator's transfer switch needs to be in good working order in the event of a power failure, the
generator would need to automatically start.
The spacing/design of the bars at the barscreen are too far apart. The debris is passing though into the equalization tank
instead of being held in the barscreen.
The audible alarm at the equalization basin worked but needs the light/light bulb to be repaired/replaced. Also, the audible
alarm wasn't working at the contact chamber. Both audible and visual alarms should be working.
100,000 GPD Plant:
The east side aeration basin was not operating the day of inspection. The ORC stated it was off-liine to be cleaned.
The east side clarifier wasn't operating the day of the inspection. The ORC stated it was off-line to be cleaned.
The skimmer on the west side Clarifier was not working.
The ORC is not using the chlorinator to displace chlorine. He is placing tablets directly in the wastestream. He stated that
he is getting a better kill of organisms.
Spot checked NDMRs and NDARs from June 2017. The operational and maintenance records that were on -site started
January 2017 through the date of inspection. MW-9 and MW-10 both appeared to be locked, tagged and in good condition.
64,000 GPD Plant
There were tanks on the back side of the plant that are not being used but have trees growing out of the tanks. The system
is in disrepair and is in need of a lot of work. The system is non-functional at this time.
The disposal site appears that there is not enough sand at the spray field. The sprinklers need to be calibrated at least once
in a permit cycle. When the spray fields were observed on, the wetted area didn't appear to distributed out enough through
the site. Only twelve sprinklers were present. It does not appear that the 20,000 square feet high rate system is working as
it was designed.
The permit has a 516,000 square feet of non -conjunctive "green area" and 12.1 acres of non -conjunctive spray field (common
area)in the description of the wastewater system. Also, there is a 3.2 million gallon irrigation pond that is on -site. the green
area, common area and pond are not being used nor have ever been used for disposal of the Village at Ocean Hill. The
system was non functional.
The 20,000 square foot conjunctive spray bed is the only disposal for the Village at Ocean Hill.
The facility is in Non-compliance at this time. Work on the list above and call back for a reinspection.
Page 2 of 7
Permit: WQ0015052
Inspection Date: 11/09/2017
Owner - Facility: Enviro-Tech of North Carolina Inc
Inspection Type : Compliance Evaluation Reason for Visit: Routine
Type
Yes No NA NE
Reuse (Quality)
❑
Infiltration System
❑
Lagoon Spray, LR
❑
Single Family Spray, LR
❑
Activated Sludge Spray, LR
❑
Activated Sludge Spray, HR
❑
Activated Sludge Drip, LR
❑
Recycle/Reuse
❑
Single Family Drip
❑
Treatment Yes No NA NE
Are Treatment facilities consistent with those outlined in the current permit? ❑ ❑ ❑
Do all treatment units appear to be operational? (if no, note below.) ❑0 ❑ ❑
Comment: The spacing/design of the bars at the barscreen are too far apart. The debris is passing though
into the equalization tank instead of being held in the barscreen. Also the skimmer on the west
side Clarifier was not working.
Treatment Flow Measurement -Influent
Yes No NA NE
Is flowmeter calibrated annually?
❑
110 ❑
Is flowmeter operating properly?
❑
❑ M ❑
Does flowmeter monitor continuously?
❑
❑ ❑
Does flowmeter record flow?
❑
❑ ❑
Does flowmeter appear to monitor accurately?
❑
❑ M ❑
Comment
Treatment Flow Measurement -Water Use Records Yes No NA NE
Is water use metered? ❑ ❑ ❑
Are the daily average values properly calculated? ❑ ❑ ❑ M
Comment:
Treatment Flow Measurement -Effluent Yes No NA NE
Is flowmeter calibrated annually? ❑ ❑ ❑
Is flowmeter operating properly? ❑ ❑ ❑
Does flowmeter monitor continuously? M ❑ ❑ ❑
Does flowmeter record flow? ❑ ❑ ❑
Does flowmeter appear to monitor accurately? ❑ ❑ ❑
Comment: The effluent flow meter was calibrated on 5/31/17 by Delta System Environmental.
Page 3 of 7
Permit: WQ0015052 Owner - Facility: Enviro-Tech of North Carolina Inc
Inspection Date: 11/09/2017 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Standby Power Yes No NA NE
Is automatically activated standby power available? M ❑ ❑ ❑
Is generator tested weekly by interrupting primary power source? ❑ ❑ ❑
Is generator operable? 0 ❑ ❑ ❑
Does generator have adequate fuel? 0 ❑ ❑ ❑
Comment: The transfer switch on the generator is broken. The generator failed to start when the power was
interrupted. The generator startee manually. The generator's transfer switch needs to be in good
working order in the event of a power failure, the generator would need to automatically start.
Treatment Barscreen
Yes No NA NE
Is it free of excessive debris?
Is disposal of screenings in compliance?
Are the bars spaced properly? ❑ 0 ❑ El
Is the unit in good condition? 0❑ ❑ El
Comment: The spacing/design of the bars at the barscreen are too far apart. The debris is passing though
into the equalization tank instead of being held in the barscreen.
Treatment Activated Sludge Yes No NA NE
Is the aeration mechanism operable? M El ❑ ❑
Is the aeration basin thoroughly mixed? 0 ❑ ❑ ❑
Is the aeration equipment easily accessed? 0 ❑ ❑ ❑
Is Dissolved Oxygen adequate? ❑ ❑ ❑
Are Settleometer results acceptable? ❑ El 0
Is activated sludge an acceptable color? 0 ❑ ❑ ❑
Comment: The east side aeration basin was not operating the day of inspection. The ORC stated it was
off-line to be cleaned.
Treatment Clarifiers
Yes No NA NE
Are the weirs level?
0
El ❑ ❑
Are the weirs free of solids and algae?
M
El ❑ EJ
Is the scum removal system operational?
M
❑ 0 ❑
Is the scum removal system accessible?
0
❑ ❑ ❑
Is the sludge blanket at an acceptable level?
0
❑ ❑ ❑
Is the effluent from the clarifier free of excessive solids?
0
❑ ❑ ❑
Comment: The east side clarifier wasn't operating the day of the inspection. The ORC stated it was off-line
to be cleaned.
Treatment Return pumps Yes No NA NE
Are they in place? 0 ❑ ❑
Are they operational? 0 ❑ ❑ ❑
Comment:
Page 4 of 7
X
CD
Cl)
O
a
CD
O
D
a
O `<
CD
3 N
3
CD (D
7 7
71,
CD
zr f
CD W
CN
X CD
N
n
N
7
� C
N
Q
CD
Q.
3 J
CD
0
Fr
CD
N
m
CD
;0
7
CD
3
CD
C11
7
O
N
CD
J
� O
.N.. < < O N N 7 S ow 7 7
O
(D CD N CD N � 0 �
Q
:3 R _ mD) N N DI CD O 0 a N N N
C1 O
CD ` CD
O N O N 7
W CD O 0 C7 N 7 w CD (QD N CD M
C
CD < m 3 m g m m v E y
CD N (p N 7 `G D Q
N Q �, a N CO) O 7 �_ (D 3 7 CD
N C (D O a N N 'G CD (D M
3 Z Q CD N N N (D 3 .O N J O
J CU N Q N N N
Q W CD
CD < N N. � J O_ O 7 7 y^
Q N C N .J N N --. �'
a (0 9' 3 a
N Q (O N 00 (D ry CD n
CD (D Q 3 - Oj V R
J J NO _0 II CD
a CD 7 Q N CD
N J N N 3
CU O N O
7 N ry C
Q Co J Q
CO CD N y
O J O
D 0 CD 0
7
J O O
CD J
()1
CD
J
0 0
O o
3 (D
CD
3 Q
CD o
CU
N
C
Cn (D
77 C
3
3 <
(D m
O
O1
ZT w
(D Q
O
a
(D C
N [y
N
N J
CD CD
N (D
CD
(D
CD
CD
CD
CD
N
Iv
=1
3
Cv O
N
7
N
N T
(Do
C
n M
_a
m
CD CD
CD 0CD
fD
a N
CD
N
O
CD
O
0
N
D
j
0
CD
CD C7
CD
N
7
J
O
CDJ
.J
CD
0..
N
N
N
N
w
w
O
7
Q
Q
J
(DD
J
❑
❑
❑
❑
❑
■
■
❑
❑
❑
■
■
■
.
N
❑
■
■
N
MEMEMEN
N
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
z
❑
❑
❑
z
❑
❑
❑
❑
❑
❑
❑ z
■■■■■❑❑❑■■■❑❑❑❑z
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
❑
m
❑❑❑z
❑
❑
m
❑❑❑❑❑❑❑z
❑
❑
❑
❑
❑
❑
❑ m
Permit: W00015052 Owner - Facility: Enviro-Tech of North Carolina Inc
Inspection Date: 11/09/2017 Inspection Type : Compliance Evaluation Reason for Visit: Routine
Is a copy of current permit available?
0
❑ ❑ ❑
Are monitoring reports present: NDMR?
E
❑ ❑ ❑
NDAR?
0
❑ El ❑
Are flow rates less than of permitted flow?
0
❑ ❑ ❑
Are flow rates less than of permitted flow?
0
❑ ❑ ❑
Are application rates adhered to?
0
❑ ❑ ❑
Is GW monitoring being conducted, if required (GW-59s submitted)?
0
❑ ❑ ❑
Are all samples analyzed for all required parameters?
0
❑ ❑ ❑
Are there any 2L GW quality violations?
❑
0 ❑ ❑
Is GW-59A certification form completed for facility?
0
❑ El M
Is effluent sampled for same parameters as GW?
0
❑ ❑ ❑
Do effluent concentrations exceed GW standards?
❑
0 ❑ ❑
Are annual soil reports available?
❑
❑ ❑
# Are PAN records required?
❑
0❑ ❑
# Did last soil report indicate a need for lime?
❑
❑ E ❑
If so, has it been applied?
❑
❑ E ❑
Are operational logs present?
0
❑ ❑ ❑
Are lab sheets available for review?
0
❑ ❑ ❑
Do lab sheets support data reported on NDMR?
E
❑ ❑ ❑
Do lab sheets support data reported on GW-59s?
0
❑ El ❑
Are Operational and Maintenance records present?
N
❑ ❑ ❑
Were Operational and Maintenance records complete?
0
❑ ❑ ❑
Has permittee been free of public complaints in last 12 months?
❑
❑ ❑
Is a copy of the SOC readily available?
❑
❑ 0 ❑
No treatment units bypassed since last inspection?
❑
❑ ❑
Comment: Spot checked NDMRs and NDARs from June 2017. The operational and maintenance records
that were on -site started January 2017 through the date of inspection.
MW-9 and MW-10 both
appeared to be locked, tagged and in good condition.
End Use -Infiltration
Yes No NA NE
# Is the application High Rate or Low Rate?
High Rate
Are buffers maintained?
0
❑ ❑ El
Are any supply wells within the CB?
❑
❑ ❑
Are any supply wells within 250' of the CB?
❑
❑ ❑
Is municipal water available in the area?
E
❑ ❑ ❑
Are GW monitoring wells required?
0
❑ R ❑
Are GW monitoring wells located properly w/ respect to RB and CB?
❑
❑ ❑
Are GW monitoring wells properly constructed. including screened interval?
0
❑ ❑ ❑
Page 6 of 7
3
0
N
0
O
Vi
R
N
K
❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑ ❑
0000000000
DEMOODDOME
❑ ❑ ❑ ❑ ❑
N
T
N
N
N
Q
N
Q
U
O
R
O)
fO
N
L3
0
I
C
O
f0
O
rn
N
N
lO
C_
E
a)
O
7
N
O
0
0
l0
N
L
O
Z
c
E
E
O
U
4