Loading...
HomeMy WebLinkAboutWQ0020793_Staff Report_20200130DocuSign Envelope ID: 750FC760-9F30-4905-BE74-6EB09B5199E9 -..-...D E Q7> January 30, 2020 State of North Carolina Division of Water Resources Water Quality Regional Operations Section Staff Report To: DWR Central Office — WQ, Non -Discharge Unit Application No.: W00020793 Attn: Poonam Giri Facility name: Tyson — Hays Hatchery, Infiltration/Evaporation Lagoon System From: Patrick Mitchell Winston-Salem Regional Office Note: This form has been adapted from the non -discharge facility staff report to document the review of both non -discharge and NPDES permit applications and/or renewals. Please complete all sections as they are applicable. L GENERAL AND SITE VISIT INFORMATION 1. Was a site visit conducted? ® Yes or ❑ No a. Date of site visit: January 28, 2020 b. Site visit conducted by: P. Mitchell & J. Henderson c. Inspection report attached? ❑ Yes or ® No d. Person contacted: Jim Brown (Tyson) and their contact information: (336) 651 - 3836 e. Driving directions: See file. II. EXISTING FACILITIES: MODIFICATION AND RENEWAL APPLICATIONS 1. Are there appropriately certified Operators in Charge (ORCs) for the facility? ® Yes ❑ No ❑ N/A 2. Are the design, maintenance and operation of the treatment facilities adequate for the type of waste and disposal system? ® Yes or ❑ No Explain anything observed during the site visit that needs to be addressed by the permit, or that may be important for the permit writer to know: Groundwater standards exceeded in MW-2 located just inside the Review Boundary. 3. Are the site conditions (e.g., soils, topography, depth to water table, etc) maintained appropriately and adequately assimilating the waste? ® Yes or ❑ No 4. Has the site changed in any way that may affect the permit (e.g., drainage added, new wells inside the compliance boundary, new development, etc.)? ❑ Yes or ® No 5. Is the residuals management plan adequate? ® Yes or ❑ No 6. Are the existing application rates (e.g., hydraulic, nutrient) still acceptable? ® Yes or ❑ No 7. Is the existing groundwater monitoring program adequate? ❑ Yes ® No Explain: MW-2 is located just inside the Review Boundary. A monitoring well needs to be installed on Compliance Boundary to determine if groundwater limits are met at the Compliance Boundar. See section IV. Additional Regional Staff Review Items below for additional information. 8. Are there any setback conflicts for existing treatment, storage and disposal sites? ❑ Yes or ® No 9. Is the description of the facilities as written in the existing permit correct? ® Yes or ❑ No 10. Were monitoring wells properly constructed and located? ® Yes ❑ No ❑ N/A 11. Are the monitoring well coordinates correct in BIMS? ® Yes ❑ No ❑ N/A 12. Has a review of all self -monitoring data been conducted (e.g., DMR, NDMR, NDAR, GW)? ® Yes or ❑ No Please summarize this review: GW limits exceeded for Ammonia in MW-2. FORM: WQROSSR 04-14 Pagel of 3 DocuSign Envelope ID: 750FC760-9F30-4905-BE74-6EB09B5199E9 13. Are there any permit changes needed in order to address ongoing BIMS violations? ® Yes or ® No Explain: BIMS list `PC' designation for this system. However, this is not a groundwater remediation system. PC certification needs to be removed in BIMS. 14. Check all that apply: ❑ No compliance issues ❑ Current enforcement action(s) ❑ Currently under JOC ® Notice(s) of violation ❑ Currently under SOC ❑ Currently under moratorium Please explain: An NOV (attached) was recently issued to the Permittee related to GW limits in MW-2. If the facility has had compliance problems during the permit cycle, please explain the status. Has the RO been working with the Permittee? Is a solution underway or in place? Yes, the Permittee is in the process of putting together a nronosal to install a new downp-radient monitoriniz well to be located on the compliance boundary in response to the NOV. Have all compliance dates/conditions in the existing permit been satisfied? ® Yes ❑ No ❑ N/A 15. Are there any issues related to compliance/enforcement that should be resolved before issuing this permit? ❑ Yes ®No❑N/A I I I M 7DIM to) &.11[I]WWto] Ii 7Brice] UVIuIDI►17rYus) ►KI 1. Do you foresee any problems with issuance/renewal of this permit? ❑ Yes or ® No 2. List any items that you would like the NPDES Unit or Non -Discharge Unit Central Office to obtain through an additional information request: 3 0 Item Reason A copy of the proposal for the new monitoring well. Language and conditions related to this new well can be added into the new permit. List specific permit conditions recommended to be removed from the permit when issued: List specific special conditions or compliance schedules recommended to be included in the permit when issued: Condition Reason Schedule conditions for the new monitoring well to be Incorporate the new well and intallation/reporting requirements, as well as an installed, along with RO updated site map showing the new well after installation while the permit is notification & approval open. conditions. 5. Recommendation: ® Hold, pending receipt and review of additional information by regional office ® Hold, pending review of draft permit by regional office ❑ Issue upon receipt of needed additional information ❑ Issue ❑ Deny 6. Signature of report preparer: Signature of regional supervi Date: January 30, 2020 state reasons: ) by: 145B49E225C94EA... FORM: WQROSSR 04-14 Page 2 of 3 DocuSign Envelope ID: 750FC760-9F30-4905-BE74-6EB09B5199E9 IV. ADDITIONAL REGIONAL STAFF REVIEW ITEMS On January 28, 2020, WSRO staff conducted a site visit to the subject facility for review associated with the application for permit renewal. Mr. Jim Brown of Tyson accompanied staff on the entire visit. The facility appears to be properly maintained and operated. The only concern noted during this review is the groundwater limit exceedances for Ammonia in monitoring well MW-2 which is located just inside the Review Boundary. An NOV was issued on December 19, 2019 (see attached) for this limit exceedance. In response to this NOV, the Permittee is proposing to install a new monitoring well on the Compliance Boundary to determine if groundwater limits are met at the Compliance Boundary. This proposal has not been received in the WSRO to date. Recommend that a copy of this proposal be requested in an add info request so that this can be incorporated with the current permitting and updated in BIMS. See the attached site map for a sketch showing the approximate area that was discussed by the onsite representative during the site visit for proposing a new downgradient monitoring well. In BIMS under the `Classification/Designation' tab, this system has been classified as WW-1 and PC -I. The PC-1 needs to be removed in BIMS, this is not a groundwater remediation system. FORM: WQROSSR 04-14 Page 3 of 3 a �e:" its ik1'y_5: 1 -i cstN ti, e • 'V.1 � s•* t� 1 11l A. /r 1 ty� ��•�j4 APPROX. LOCATIONS NOT TO SCALE Site Map WQ0020793 voo an 4` MW72 �� � , a � 4.e �f �� Ffi�y�ryy'�q�t �'� �., t x1�Y�i5 •> ..r � 0. t S !f f '-,C-'1�� Ny,. yst a.+ .4 �. i �I+! fk , t � � • - 1. ,y, ' ' 6 VA t . ��..,tJ y "�a''. L� � •�ry t°; '��i°�� � � .� y 1�,� � s{�` � 1.-_� �,?`_ '� �a � �.. �j'� � `��b - e�.- Aro -E rj a�s� IN rR� - �d5�6�-:+�, � 77 .r T � M� r`'1.' s a I..;t �•e: �t�� ^ti ..,�` � `?, . y:a. North Carolina Department of Environmental Quality Division of Water Resources Water Quality Section NON -DISCHARGE COMPLIANCE INSPECTION REPORT INFILTRATION -EVAPORATION POND General Information Facility Name: Permit No.: W000 2D i Owner: r 'FA/h ORC Name. J;m Backup ORC: _&q Other Contact: DOµ Location (address, gps or County: W d ke r Issuance Date: ZD/7 Expiration Date: I t ,wae g 33G 5 -3 31 Telephone No : 3,Z' - A3 - 2) 7/ ea SZP 3a2 - Zooe Telephone No.: Telephone No.: — Nw tl a,, R AfJ. 14111c Ble K &rp- t1a. TcN Lv(4, Reason for Inspection YIF ❑ ROUTINE ❑ FOLLOW-UP ElCOMPLAINTERMITTING ❑ Other: Comments (attach additionalpages as necessary v,-ZA Ai c �innSe� Fo Sysnn ? fJ o. S � J'1/ tarp t�10 !� _ s. l!(eJ i � of Ml�l �pl«ce 4mj1,1'ov, Pc�✓•�/' totI/. �, c., ifCu1J AD r1ei U 11" v�•i2J `r°� �Ql� W,�I � t-��� '� Is a follow-up inspection Primary U'� z - T, M r7Zln t 1)r_ Date of Inspection:I&Y1262.0 ❑ No '✓��'nn lycnat�JO �, Entry Time: 0 : SRn Exit Time: I Z 14 r1