Loading...
HomeMy WebLinkAboutWQ0041382_Application (FTSE)_20191220Id State of North Carolina DWR l� Department of Environmental Quality Division of Water Resources Dhrlsion of Water Resources 15A NCAC 02T .0300 - FAST TRACK SEWER SYSTEM EXTENSION APPLICATION FTA 04-16 & SUPPORTING DOCUMENTATION Application Number. t! U t (m be rmop1CMd by DWR) All Items trust be coot leted b r � ! or t e 2P Xication will be returned I. APPLICANT INFORMATION: w,c !. Applicant's name: $ l� tih>tiAirn_otiAuthorilY (company, municipality. HOA. utility, etc.) ,- 2. Applicant type: ❑ Individual ❑ Corporation rP El General Partnership ❑Privately -Owned Public Utility ❑ Federal ❑ State/County ❑ Municipal ® Other f 3. Signature authority's name: Micj ae LandetEth per 15A siticl7�� Title: 4. Applicant's mailing address: 1000 Tradc rare P BO 00 City: &M—Aimoa State: CC Zip: ?7623-0 01 5. Applicant's contact information: y� Phone number. (914) R4077747 Email Address: jim.no-akLwrdu cam 11. PROJECT INFORMATION: a 1. Project name: 1ZIM O E 2. Application/Project status: ® Proposed (New Permit) ❑ Existing Permit/Project N O ?DO If a modification, provide the existing pertnit number WQ00 and issued date. .a C%J If now construction but part of a master plan, provide the existing permit number. WQ(10 a.. a W C7 ^4 3. County where project is located: Wake y C.) 4. Approximate Coordinates (Decimal Degrees): Latitude: 7 8 3 ' Longitude: -�` ❑ U 5. Parcel ID (if applicable): NC -PIN Q756597431 z (or Parcel ID to closest downstream sewer) III. CONSULTANT INFORMATION: 1. ProfessionaI Engineer: kr1mv Rivenbark License Number: 030 Ol Firm: CISAC2flycyance,PLL Mailing address: 320 S. ACADEMY T City: Cary Stare: NC Zip: 2751 I -- Phone number. (9L9) B9 -IL72 Email Address: ' iven rk(cy •j.KQnv0,1ncc.Mm IV. WASTEWATER TREATMENT FACILITY (m,-"-CF) INFORMATION: r G) 4 1. Facility Name: b h Water R Permit Number. lamation Facilit'. b 3 rJ !` 1 �--•� _ Owner Name: awn of Can V. RECEIVING DOWNSTREAM SEWER INFORMATION (if different than WWTF): I. Permit Number(s): WQ Downstream (Receiving) Sewer Size: 36 inch Stem W41, Collection S��x1rm Permit tiumbeefa) ftfapnitcable): WQCS I�Qa j 3 Owner Name(s): Jowl, f Cam FORM: FTA 04- I6 Page I of 5 VI. GENERAL REQUMEMENTS 1. If the Applicant is a Privately -Owned Public Utility, has a Certificate of Public Convenience and Necessity been attached? ❑ Yes ❑No CON/A 2. If the Applicant is a Developer of lots to be sold, has a Deve u e 's Operational Agrcement t F(-Rht; tit ", been attached? ❑ Yes [—]No ®N/A 3. If the Applicant is a ljoEge P ellt�wncrs' Association has an O errtio a] , reem— I M12 RI- 1 f01� been attached? ❑ Yes ❑No ®N/A 4. Origin of wastewater: (check all that apply): ❑ Residential Owned ® Retail (stores, centers, malls) ❑ Car Wash ❑ Residential Leased ® Retail with food preparation. service ❑ Hotel and/or Motels ❑ School / preschool / day care ❑ .Medical / dental i veterinary facilities ❑ Swimming Pool /Clubhouse ® Food and drink facilities ❑ Church ❑ Swimming Poot/Filter Backwash ® Businesses / offices / factories ❑ Nursing Home ® Other (Explain in Attachment) 5. Nature of wastewater : °16 Domestic/Commercial Ida/o Commercial °/° Industrial ( 5A NCAC 02T.0 0120 ) 1 , Is there a Pretreatment Program in effect? ❑ Yes ❑ No 6. Has a flow reduction been approved under 156 NCAC 0AT .01 L4W? ❑ Yes ❑ No 1- If ves, Provide a cony of flow reduction approval letter 7. Summarize wastewater generated by project: Establishment Type (see 211.01140 Daily Design Flow 0,4 Ih{o, of [mils' Fla►r gat/ gall gal/ gat/ gall gall Total GPD GPD GPD GPD GPD GPD GPD a See 15A NCAC 02T .01 14(b1. (d) rrl(I) and (e)(2) for caveats to wastewater design flow rates (i.e., minimum flow per dwelling; proposed unknown non-residential development uses. public access facilities located near high public use areas; and residential property located south or avast of the Atlantic Intracoastal Waterway to be used as vacation rentals as defined in fi.S,42A-4). b Per 15A NCAC 02T .0I 14(c), design flow rates for establishments not identiCcd [in table jj&jLC..AC Q2T.0114] shall be detertnincd using available flow data, water using ftxrures. occupancy or operation patterns, and other measured data. 8. Wastewater generated by project: 0 GPD (per 15A NC_ACD T tQ 114) Do not include future flows or prcviously permitted allocations If permitted flow is zero, indicate why; ❑ Pump Station or Gravity Sewer where flow will be permitted in subsequent permits that connect to this line ❑ Flow has already been allocated in Permit Number. ® Rehabilitation or replacement of existing sewer with no new flow expected ❑ Other (Explain), - FORM. F l'A 04-16 Page 2 of 5 YII. GRAVITY SEWER DESIGN CRITERIA (If Applicable) - 02T .0305 & X111C Gravity Sewers) - I. Summarize gravity sewer to be permitted: Size (inches) Length (feet) Material N/A > Section 11 & III of the MDC for Permitting of Gravity Sc A'crs contains information related to design criteria % Section III contains information related to minimum slopes for gravity sewer(s) Over•sizing lines to meet minimum slope requirement is not allowed and a violation of the MDC VIM PUMP STATION DESIGN CRITERIA (If Applicable) — 02T .0305 & MDC IPrimp Stations/Force itainst: COMPLETE FOR EACH PUMP STATION INCLUDED IN THIS PROJECT 1. Pump station number or name: Puml! statign m c' stin g and ut ide of projecti i •c 2. Approximate Coutdinates (Decimal Degrees)- Latitude: 85 z Longitude:-78.80418° 3. Design flow of the pump station: millions gallons per day (firm capacity) 4. Operational point(s) of the pump(s): gallons per minute at feet total dynamic head (TDH) 5. Summarize the force main to be permitted (for this Pump Station): Size (inches) Length Ifeet) Material 8" 313 DIP 6_ Power reliability in accordance with 15A NCAC 02T .0305(h)t i )- ❑ Standby power source or pump with automatic activation and telemetry - 15A NCAC 02T 0305(h)(1)(i3) D Required fur all pump stations with an average daily flow greater than or equal to 15.000 gallons per day Must be permanent to facility Or if the pump station has an average daily flow less than 15.000 gallons per day_ ❑ Portable power source with manual activation, quick -connection receptacle and telemetry - 15A NCAC 02T .0305(h)(1)(C) or ❑ Portable pumping unit with plugged emergency pump connection and telemetry - 15A NCAC 02T .0305(h)(1)(C): It shall be demonstrated to the Division that the portable source is owned or contracted by the applicant (draft agreement) and is compatible with the station. ➢ If the portable power source or pump is dedicated to multiple pump stations, an evaluation of all the pump stations' storage capacities and the rotation schedule of the portable power source or pump, including travel timehames, shall be provided in the case of a multiple station power outage. FORM: FTA 04-I6 Page 3 of 5 IX. SETBACKS & SEPARATIONS -- (02B .0200 & 15A NCAC 02T .0305(t)): I Does the project comply with all separations found in 15A N ' .0103 l ® Yes ❑ No 15A NCAC 02T.0305 f► contains minimum separations that shall be rovided for sewer sN,stems: not listed below Water mains "*Any private or public water supply source, including any wells. WS-1 waters of Class 1 or r11___ .. . . _ "Waters classified WS (except WS-I or WS-V), B, SA, ORW, HQW, or SB from normal high water for tide elevation and wetlands Isee item IX21 "Any other stream. lake, impoundment, or ground water lowering and surface drainage rtitfth. An Fi Separation Re uired 24 inches 18 inches 10 feet 18 inches 2 feet 100 feet 50 feet 10 feet rE5 feet 5 0 feet 0 feet feet 10 feet 36 inches 15A NCAL92T.01()5W contains alternatives where separations in 02T Ll) cannot be achieved. ""Stream classifications can be identified using the Division's NC �urfacc Water C iassificat aU web a c If noncompliance with 02'f {1305 or see Section x of this application of embankment or cuts 2. Does the projcct comply with separation requirements for wetlands? (50 feet of separation) ❑ Ye5 Y Seethe Division's draft separation requirements for situations where separation cannot be meet ❑ NO ®NrA Y No variance is required if the alternative design criteria specified is utilized in design and construction Y As built documents should reference the location of areas effected 3. Does the project comply with setbacks found in the river basin rules per I �A NG'AC 02B 020U? El Yes ❑ No Y This would include Trout Buffered Streams per 5 ? �2 ®NrA 4. Does the project require coverage/authonzatron under a 404 Nationwide or individual permits or 401 Water Quality Certifications? El Yes No lr Information can be obtained from the 3ufftr P itt R n I 5. Does project comply with 15A NCAC 2T.0 5(yjt6) (additional permits/ccrtifications)? ® Yes ❑ No Per 15A NC -AC 21.[►1 ?� 61, directly related environmental permits °r certification applications are being prepared, have been applied for, or have been obtained. Issuance of this permit is contingent oo issuance of dependent permits (erosion and sedimentation control plans, stormwater management plans, etc.). Does this project include any sewer collection lines that are deemed "high -priority?" Per I SA N -AC 02LO402, "high -priority sewer" means "any aerial sewer, sewer contacting surface waters, siphon, or sewer positioned parallel to streambanks that is sub' that undermines or deteriorates the sewer. �'J - "e,1 ❑ Yes No ® N/A D If yes, include an attar ment with details for each line, including type (aerial line, size, material, and location'). High priority lines shall be inspected by the perrnittee or its representative at least once every six -months and inspections documented per I5A NCAC 02T.0403(a)(5) or the permitee's individual System -Wide Collection permit. NORM: FTA 04-16 Page 4 of 5 X, CERTIFICATIONS: I. Does the submitted system comply with 15A LN_CAC 021T, the Mm murn fkslgn—C,'rited'ifur e Venliating of_Pump _Si _Inns allLl Poru_Nlacns (latest vmion►. and the QMvltySewer Minimum Design Criteria (latest version) as applicable? ® Yes ❑ No If No, complete and submit the Variance/Alternative Design Request application (VADC 10-14) and supporting documents for review. Apgrovgl of the request is required 12rior to submittal of the Fast Track Aptillcation and sunporting documents. 2. Professional Engineer's Certification: I'P. attest that this application for (Professional Engineer's name from Application Item III. I.) has been reviewed by me and is accurate, complete and consistent with the information supplied in the plans, specifications, engineering calculations, and all other supporting documentation to the best of my knowledge. I further attest dial to the best of my knowledge the proposed design has been prepared in accordance with the applicable regulations, Gravity Sewer Minimum Design Criteria for Gravity Sewers (latest version), and the Minimum Design Criteria for the Fast -Track Permitting of Pump Stations and Force Mains (latest version), Although other professionals may have developed certain portions of this submittal package, inclusion of these materials under my signature and seal signifies that I have reviewed this material and have judged it to be consistent with the proposed design. NOTE — In accordance with General Statutes 143-215 6A and 143-215.613, any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S 10.000, as well as civil penalties up to $25,000 per violation. North Carolina Professional Engineer's seal, signature, and date: ����ZN CAR INC A r11E�1v� �� la�t`t j M 3. Applicant's Certification per 15A NCAC 02T ,0106(b): I, MiQ laalndg uff Presid " "_ attest that this application for (Signature Authority's name & title from Application Item 1.3.) has been reviewed by me and is accurate and complete to the best of my knowledge. I understand that if all required parts of this application are not completed and that if all required supporting documentation and attachments ate not included, this application package is subject to being returned as incomplete. I understand that any discharge of wastewater from this non - discharge system to surface waters or the land will result in an immediate enforcement action that may include civil penalties, injunctive relief, and/or criminal prosecution. I will make no claim against the Division of Water Resources should a condition of this permit be violated. I also understand that if all required parts of this application package are not completed and that if all required supporting information and attachments are not included, this application package will be returned to me as incomplete. NOTE — In accordance with General Statutes 1 d -215 ,A and 143-215_0 , any person who knowingly makes any false statement, representation, or certification in any application package shall be guilty of a Class 2 misdemeanor, which may include a fine not to exceed S I0,000 as well as civil penalties up to $25,000 per violation. Signature: FORM: FTA 04-16 Dale; V�� m Alaarnv d 8S to form. Le t-1 Coons Page 5 of 5 ConveyanceYLLC October 23, 2019 Raleigh Regional Office Water Quality Section Division of Water Resources NC Department of Environmental Quality 1628 Mail Service Center Raleigh, NC 27699 Re: 1-5700 — RDU Airport force main relocation 320 S. Academy St Cary, NC 27511 919-890-3876 www,cisconve ance.com NC Dept of Environmental Quality DEC 2 n 2019 Raleigh Regional Office We respectfully submit an application package for a Fast Track Sewer System Extension Permit on behalf of Raleigh Durham International. NCDOT has designed a roadway project (1-5700) at 1-40 and Airport Blvd that will rework the interchange itself as well as some nearby roads. Pleasant Grove Church Road is being realigned at Airport Blvd to accommodate the new interchange. The Airport has an existing force main that is conflict with the new alignment of Please Grove Church Road. We plan to parallel a short section the existing force main with a new force main. We have not been able to locate original permits for the existing force main. As such, we understand that a new permit will be required for the relocation. Since this is a relocation, there is no new flow associated with the proposal. Hot taps, with tapping sleeve and valves, are proposed to accomplish this work to avoid a shutdown of the upstream pump station and force main. No changes are proposed at the pump station itself. Our design of the sewer force main relocation is being included in the overall NCDOT construction project contract. Any permits required of the overall project, excluding the utility permits, are being handled by NCDOT. All work will be performed within right of way obtained by NCDOT. Please do not hesitate to contact me should you have any questions or concerns. We appreciate your time and consideration regarding this matter. Sincerely, PV" Jeremy Rivenbark, PE Project Manager til P b � 4138d Cashion, Ted From: Jewett, Ron <RonJewett@rdu.com> Sent: Friday, January 24, 2020 7:25 AM To: 'Ben Baker' Cc: Cashion, Ted; Jeremy Rivenbark; Cayton, Ellis Subject: [External] RE: RDU 1-5700 sewer force main relocation application revision real erft% Do not elidofink5 or -open atta+. h ents unless,you verify. Send..'a11 suspicious email as an atWe-fimerit4to s a. Ben, I've been authorized to give the okay for this slight revision. Please proceed. Thank you. Ron VP Facilities Asset Management RDUAA 919-840-7736 From: Ben Baker <bbaker@cjsconveyance.com> Sent: Thursday, January 23, 202012:50 PM To: Jewett, Ron <Ron.Jewett@rdu.com>; Cayton, Ellis <EIIis.Cayton@rdu.com> Cc: Cashion, Ted <ted.cashion@ncdenr.gov>; Jeremy Rivenbark <jriven bark @cjsconveyance.com> Subject: RDU 1-5700 sewer force main relocation application revision Ron and Cayton, Ted Cashion (CC'ed) with the State is reviewing the permit application for the sewer force main relocation that CJS Conveyance designed for the airport. There was one question on the application where we should have selected "No" instead of "N/A". We need to revise that answer on the previously signed form. The section in question is shown below. We interpreted that question incorrectly. We considered a sewer collection line to be distinct from a sewer conveyance line (gravity versus force main), so we marked "N/A". However, that was not the intent of the question. Since our sewer lines are not "high priority", we believe selecting "No" is appropriate. It IJ,hc 111111. Ofctm Ills lull..111% S-ll 4'1 1 0110. Il,trl lilt.~ lltill, dt,JV%:IJJL-d"111:;11 I+I I:.. 1'U I ' i \t i1 1l, I' uIII' ' Illr ll I'l ltl[111 .Lt\Lr IIIL,IIIS ­ 311% .It'f7111 +t '.LII Sokvr ko.,t,l,ltll'' rufl t.l I►,1[�r., +l I61NW. of +L'11l I+llltll in,: d par IIle I ;t1 c,rc Lmh IIA,< III -II I'SI11tj C11 11 1 Ch.siPtl III II IIndeml tfii G .1,' �fk Iirl.lr It I) +. tSCr 01'r. ❑`,I 1iti 1 n, I cfC ,111 JT;.1. f,nwn1 %i;h l'A 1-11111$T C.1Lh 1141_, In, II Id I II'y; V,hC I I,-rt.1I -In,:. ti 7C n1.11CT1.1� anti 10,:XtOn) Ili;,0h PI 10fil l lincL ,,Ilali bV IMI)CLlcd In [lit Ilrl111iltrr III it% f rhl r►rlllati%C at lratt UIILr r\cr% ti11-111ut1111% ind ir1t11CC1iU1I% d.Iculrlrnrul llrl I,; ,% M 1C II] 1.041111a11;1III, [hv 104-111nicr'% Inllilidurl N%%IcuIAII illr C1011ccliuu prrlint ; I IRAI I r l I.: ;,. 1 Jeremy has authorized the change on the application as the engineer. In order for Ted to make this change to "No" on the application for us, he is requesting that the Mr. Landguth email him authorization to revise the application. Would it be possible to have him respond to this email allowing the change? Thanks! Benjamin Baker, El 320 S. Academy Street Cary, NC 27511 919.890.3876 (main) 919.890.3882 (direct) bbaker@c*sconveyance.com i cisconve ance.roi77 Cashion, Ted From: Cashion, Ted Sent: Wednesday, January 22, 2020 3:35 PM To: Jeremy Rivenbark;jim.novak@rdu.com Cc: Robinson, Jason; Shuyan Tian (Shuyan.Tian@townofcary.org); Deck, Erin M Subject: RE: [External) RE: RDU 1-5700 fast track sewer extension application We'll also need approval from the applicant's signature authority, Michael I_andguth, to revise the application. Please have him send an email authorizing the revision to the application. ted Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion@ncdenr.eov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 Osp►r.�wRta�[mrorwraW pui'I Subscribe to Collection System & Sewer Permitting Updates Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. From: Cashion, Ted Sent: Wednesday, January 22, 2020 3:29 PM To: Jeremy Rivenbark <jrivenbark@cjsconveyance.com>; jim.novak@rdu.com Cc: Robinson, Jason <jason.t.robinson@ncdenr.gov>; Shuyan Tian (Shuyan.Tian@townofcary.org) <Shuyan.Tian@townofcary.org>; Deck, Erin M <erin.deck@ncdenr.gov> Subject: RE: [External) RE: RDU 1-5700 fast track sewer extension application Per your email, I'll make the change to the app. We'll issue the permit asap. ted Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cash ion P ncdenr. ov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 Subscribe to Collection System & Sewer Permitting Updates Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation. From: Jeremy Rivenbark mailto:'rivenbark@cisconveyance.com] Sent: Wednesday, January 22, 2020 3:09 PM To: Cashion, Ted<ted.cashion@ncdenr.gov>;novak@rdu.com Cc: Robinson, Jason <'ason.t.robinson ncdenr. ov>; Shuyan Tian (ShuYan.Tian(@townofcary.ore) <Shu an.Tian townofca .or >; Deck, Erin M <erin.deckPncdenr.8ov> Subject: (External] RE: RDl1 1-5700 fast track sewer extension application ernail as an atiacOment io Ted, Thanks for the feedback and responses to help move this along. Item IX.6 can be marked "no" rather than N/A. Do we need to resubmit the form with this change or does this email suffice? Thank you, Jeremy A. Rivenbark, PE 320 S. Academy Street Cary, NC 27511 919.890.3878 (direct) 919.812.4116 (mobile) Cashion, Ted From: Jeremy Rivenbark <jrivenbark@cjsconveyance.com> Sent: Wednesday, January 22, 2020 3:09 PM To: Cashion, Ted; jim.novak@rdu.com Cc: Robinson, Jason; Shuyan Tian (Shuyan.Tian@townofcary.org); Deck, Erin M Subject: (External] RE: RDU 1-5700 fast track sewer extension application • External email. Do not dick links or open attachments unless you verify. Send all suspicious email as are attachment, to pQrt.spamprFc.gov Ted, Thanks for the feedback and responses to help move this along. Item IX.6 can be marked "no" rather than N/A. Do we need to resubmit the form with this change or does this email suffice? Thank you, Jeremy A. Rivenbark, PE �4 Lk 320 S. Academy Street Cary, NC 27511 919.890.3878 (direct) 919.812.4116 (mobile) Lvenbark@cisconveyance.com I cisconveyance.com Click here to upload large files. From: Cashion, Ted <ted.cashion@ncdenr.gov> Sent: Wednesday, January 22, 2020 7:47 AM To: Jeremy Rivenbark <jrivenbark@cjsconveyance.com>; jim.novak@rdu.com Cc: Robinson, Jason <jason.t.robin son@ncdenr.gov>; Shuyan Tian (Shuyan.Tian@townofcary.org) <S h uya n.Tian @town ofca ry.o rg>; Deck, Erin M <erin.deck@ncdenr.gov> Subject: RDU 1-5700 fast track sewer extension application Jeremy, We are reviewing the subject application. Item IX.6 was marked "NA' for high priority lines. Please confirm (by either'yes or no') if this project contains high priority lines as defined in 15A NCAC 02T .0402. Items IV and V of the application were not completed as required. In the future, please contact the owner of the treatment plant to obtain this information; please do not leave items on the application blank. We will complete this section for you this time (IV - WWTP permit no. is NC0048879; V. collection system permit no. is WQC500013). Incomplete applications increase review time, require that we send requests for additional information, and delay the issuance of permits. Please ensure all applications are fully completed prior to submittal to expedite issuance of permits. We will continue drafting the permit upon submittal of the above. ted Ted Cashion Water Quality Regional Operations Division of Water Resources NC Department of Environmental Quality Raleigh Regional Office 919-791-4254 ted.cashion@ncdenr.eov 1628 Mail Service Center Raleigh, NC 27699-1628 3800 Barrett Drive Raleigh, NC 27609 Crj'A.S-Z',; �f {r.rrr-c-.�nLt.Cu Subscribe to Collection System & Sewer Permitting Updates Email correspondence to and from this address may be subject to the North Carolina Public Records Law and may be disclosed to third parties unless the content is exempt by statute or other regulation.