Loading...
HomeMy WebLinkAboutNC0026573_Industrial User_20200113 (e[14,2,t)., tdarliellrieit CITY OF MORGANTON PRETREATMENT PO Box 3448 Morganton,NC 28680-3448 RECEIVED January 13,2020 JAN 2 1 2020 Vivien Zhong NC DEQ PERCS NCDEQIDWRINPDES 1617 Mail Service Center Raleigh,NC 27699-1617 Subject:Case Farms Industrial User Permit(IUP)renewal Ms.Zhong: I have enclosed the IUP renewal information for Case Farms,Morganton NC. The following items have been included: 1) Copy of letter to Case Farms concerning the permit renewal. 2) New cover page. 3) Permit history page 4) IUP renewal 5) IUP synopsis 6) SIU application 7) POTW latest inspection 8) Allocation table I would like to thank you for all of your help this past year on helping me with the pretreatment program.I have made every effort to include all of the required documents. If you have any questions,please contact me at(828)438-5376. Sincerely, Tim Arney Pretreatment Coordinator City of Morganton a TN C ARo CITY OF MORGANTON PRETREATMENT PO Box 3448 Morganton,NC 28680-3448 RECEIVED JAN 21 2020 January 10,2020 NCDEQ/DWR/NPDES David McHugh Case Farms PO Box 308 Morganton,NC 28655 Subject: Industrial User Permit(IUP)renewal Mr.McHugh: Your Industrial User Permit(IUP# 1098)is enclosed. This permit renewal is issued in response to your Industrial User Wastewater Survey and application,which was received by the Control Authority on December 4,2019.This permit is issued pursuant to the requirements of North Carolina General Statute 143-215.1 and the local Sewer Use Ordinance. Please take the time to review your permit carefully.No modifications to your discharge parameters have been made to the permit at this time.This permit is valid from May 31,2020,until May 31,2025.Also, please be aware that final approval for this permit renewal must come from the NC Division of Environmental Quality,PERCS Unit. If any parts,measurement frequencies,or sampling requirements contained in this permit are unacceptable to you,you have the right to an adjudicatory hearing upon written request within thirty(30)days following receipt of this letter. The City of Morganton appreciates Case Farms for their continued support of the Pretreatment Program, and the outstanding job you and your staff does.If I can be of any help,please do not hesitate to contact me at(828)438-5376. Sincereelyy,, Tim Arney Pretreatment Coordinator City of Morganton City of Morganton,NC Control Authority and/or Municipality PERMIT RECEIVED Industrial User Pretreatment Permit(IUP) JAN 2 1 2020 To Discharge Wastewater Under the Industrial Pretreatment Program NCDEQ/DWR/NPDES 1098 N/A IUP Number 40 CFR Category(if Applicable) In compliance with the provisions of North Carolina General Statute 143-215.1, any applicable federal categorical pretreatment regulations, all other lawful standards and regulations promulgated and adopted by the North Carolina Environmental Management Commission, and the Control Authority and/or Municipality Sewer Use Ordinance. The following Industry, hereafter referred to by name or as the permittee: Industry name,permittee: Case Farms Facility Located at Street Address 121 Rand Street City Morganton State,Zip North Carolina 28655 Is hereby authorized to discharge wastewater from the facility located at the above listed address into the sanitary sewer collection system and the wastewater treatment facility of the Control Authority and/or Municipality listed below: IUP Control Authority and/or Municipality WWTP name: Catawba River Pollution Control Facility NPDES Number: NC0026573 WWTP Address: 1000 Vine Arden Road City,State,Zip Morganton,NC 28655 In accordance with effluent limitations, monitoring requirements, and all other conditions set forth in Parts I, II, and III of this Industrial User Pretreatment Permit(IUP). Effective date, this permit and the authorization to discharge shall become effective at midnight on this date:. May 31,2020 Expiration date,this permit and the authorization to discharge shall expire at midnight on this date: May 31, 2025 Date signed Pretreatment Coordinator Industrial User Pretreatment Permit (IUP) PART I Specific Conditions IUP, PART I, OUTLINE: A.) IUP Basic Information B.) IUP Modification History C.) Authorization Statement D.) Description of Discharges E.) Schematic and Monitoring Locations F.) Effluent Limits &Monitoring Requirements G.) Definitions and Limit Page(s) notes A. IUP Basic Information: Receiving Control Authority&WWTP name: POTW NPDES#: Catawba River Pollution Control Facility NC0026573 IUP Name: IUP Number: Case Farms 1098 IUP Effective date: Pipe Numbers,list all regulated pipes: May 31, 2020 01 IUP Expiration date: IUP 40 CFR#(if applicable),or N/A: May 31, 2025 N/A B. IUP History. A Complete Permit History is required): Effective Renewal or Description of changes over previous IUP. Date Modification 5/31/95 No description of modification or renewal in IUP history. 4/1/99 Modified To increase flow limit, to add flow measurement procedure,to correct Description of IUP Discharge and to add monthly to all of limits page. 5/31/00 Renewal Permit renewal. Two stage permit to reflect flow increase once construction is complete. 10/01/00 Modified Added treatment units, changed description of discharge, added slug/spill plan requirements for additional information to be added to general spill plan already in place. 5/31/05 Renewal Permit renewal, no changes in discharge or flow at this time. 5/31/10 Renewal Permit renewal,no changes in discharge or flow at this time. 2 Industrial User Pretreatment Permit (IUP) PART I Specific Conditions 7/21/10 Modified Revised permit to correct an error in description of IU Treatment Units and description of IUP discharge. 3/1/2012 Modified Revised permit to reflect a request in discharge flow from 0.900 mgd to 1.5 mgd. This revision also will result in a reduction of TSS limits from 675 mg/1 to 400 mg/1, and a reduction of BOD limits from 700 mg/1 to 600 mg/1. These reductions are necessary in order to prevent over allocation. 5/31/2015 Renewal Permit renewal, no changes in discharge or flow at this time. 10/1/2015 Modified Permit modified to reflect a request in discharge flow from 1.500 mgd to 2.000 mgd. This modification will also result in a reduction of current BOD limit of 600 mg/1 to 500 mg/l. TSS limit will remain unchanged at 400 mg/1. This reduction is necessary in order to prevent over allocation. 11/9/2018 Modified Case Farms has requested a modification in their monthly discharge reporting. Case Farms has requested that BOD and COD be changed from concentration to pounds per day. This modification in reporting would not result in a change in pounds of BOD or COD allocated to Case Farms. 5/31/2020 Renewal Permit renewal,no changes in discharge or flow at this time. 3 Industrial User Pretreatment Permit (IUP) PART I Specific Conditions C.) Authorization Statement: 1.) The Permittee is hereby authorized to discharge wastewater in accordance with the effluent limitations, monitoring requirements, and all other conditions set forth in this Industrial User Pretreatment Permit (IUP) into the sewer collection system and wastewater treatment facility of the Control Authority and/or Municipality. 2.) The Permittee is hereby authorized to continue operation of and discharge wastewater from the following treatment or pretreatment facilities. These facilities must correspond to the treatment units listed on both the application and inspection forms. IU Treatment Units List all Treatment Units: Descriptions: Screening Grit removal Grease Trap DAF Unit Flow equalization basin PH adjustment 3.) The Permittee is hereby authorized to, if required by the Control Authority and/or Municipality and after receiving Authorization to Construct (A to C) from the Control Authority and/or Municipality, construct and operate additional pretreatment units as needed to meet final effluent limitations. D.) Description of IUP Discharge(s): 1. Describe the discharge(s) from all regulated pipes. Pipe#001,Description of Discharge: Discharge from this pipe will include all process wastewater, Boiler blowdown, and Cooling Tower blowdown. E.) Schematic and Monitoring Locations: The facility schematic and description of monitoring location(s) given below must show enough detail such that someone unfamiliar with the facility could readily find and identify the monitoring location(s) and connection to the sewer. Include and identify all regulated pipes. 4 IUP Part 1 Section F: Receiving POTW name=> Catawba River IU name=> Case Farms Receiving POTW NPDES#=> NC0026573 IUP#_> 1098 Effluent Limits and Monitoring Requirements Effective date for these Limits=> 5/31/2020 Pipe#_> 001 Expiration date for these Limits=> 5/31/2025 40 CFR#_> N/A The Permittee may discharge from this specific If not applicable put N/A Pipe number according to these specific dates, THE LIMITS ON THIS PAGE ARE,(Check one below): effluent limits, and monitoring requirements LIMITS for ENTIRE permit period => X INTERIM Limits for period# 1 => __ INTERIM Limits for period#2 => FINAL Limits Page => Concentration Limits Mass Limits Monitoring Frequency Sample Required Collection Laboratory Monthly Monthly Method Detection Daily Max Average Units Daily Max Average Units By Industry By POTW (C or G) Level 1 Flow 2.000 MGD 2.000 MGD Monthly Monthly C 2 BOD mg/1 8340 lbs/day Monthly Monthly C 3 TSS 400 mg/I lbs/day Monthly Monthly C 4 Temperature N/A 5 PH 6.0-11.0 Std.units Std.units Monthly Monthly G OTHER PARAMETERS; Please List Alphabetically 6 COD mg/I 33360 lbs/day Monthly Monthly C 7 Oil&Grease 100 mg/I lbs/day Monthly Monthly _ G 8 9 10 11 12 13 14 _ 15 16 17 18 19 20 21 22 23 5 Industrial User Pretreatment Permit (IUP) PART I Specific Conditions G.) Definitions and Limit Page(s) notes: In addition to the definitions in the Town of Morganton, NC Sewer Use Ordinance the following definitions and requirements apply: 1. Composite Sample: Unless defined differently below, a composite sample for the monitoring requirements of this IUP, is defined as the automatic or manual collection of one grab sample of constant volume, not less than 100 ml, collected every hour during the entire discharge period on the sampling day. Sampling day shall be a typical production, and discharge day. 2. Composite Sample, alternative definition: A composite sample for the monitoring requirements of this IUP is the same as described above unless specifically defined below as the automatic or manual collection of constant volume and constant time grab samples collected and composited according to the following criteria: Specific volume of each grab sample= Milliliters Specific time interval between samples = Hours Total duration of sample collection period= Hours Total number of grab samples to be composited= Samples 3. Daily Monitoring Frequency Daily Monitoring Frequency as specified in this IUP shall mean each day of discharge. 4. Grab Sample Grab sample for the monitoring requirements of this IUP, is defined as a single "dip and take" sample collected at a representative point in the discharge stream. 5. Instantaneous measurement An Instantaneous measurement for the monitoring requirements of this IUP is defined as a single reading, observation, or measurement. 6 Industrial User Pretreatment Permit (IUP) PART II General Conditions Outline of PART II, 1. Representative Sampling 16. Federal and/or State Laws 2. Reporting 17. Penalties 3. Test Procedures 18. Need to Halt or Reduce 4. Additional Monitoring by 19. Transferability Permittee 5. Duty to comply 20. Property Rights 6. Duty to Mitigate 21. Severability 7. Facilities Operation, Bypass 22. Modification, Revocation, Termination 8. Removed substances 23. Reapplication 9. Upset Conditions 24. Dilution Prohibition 10. Right of Entry 25. Reports of Changed Conditions 11. Availability of Records 26. Construction of pretreatment facilities 12. Duty to provide information 27. Reopener 13. Signatory Requirements 28. Categorical Reopener 14. Toxic Pollutants 29. General Prohibitive Standards 15. Civil and Criminal Liability 30. Reports of Potential Problems 1. Representative Sampling Samples and measurements taken as required herein shall be representative of the volume and nature of the monitored discharge. All samples shall be taken at the monitoring points specified in this permit and, unless otherwise specified, before the effluent joins or is diluted by any other wastestream, body of water, or substance. Monitoring points shall not be changed without notification to,and approval by,the permit issuing authority. 2. Reporting a.) Monitoring results obtained by the permittee shall be reported on forms specified by the Control Authority and/or Municipality, postmarked no later than the twentieth day of the month following the month in which the samples were taken. If no discharge occurs during a reporting period (herein defined as each calendar month) in which a sampling event was to have occurred, a form with the phrase "no discharge" shall be submitted. Copies of these and all other reports required herein shall be submitted to the Control Authority and/or Municipality and shall be sent to the following address: Tim Arney Pretreatment Coordinator Catawba River Pollution Control Facility PO Box 3448 1000 Vine Arden Road Morganton,NC 28680-3448 b.) If the sampling performed by the permittee indicates a violation, the permittee shall notify the Control Authority and/or Municipality within 24 hours of becoming aware of the violation. The permittee shall also repeat the sampling and analysis and submit the results of the repeat analysis to the Control Authority and/or Municipality within 30 days after becoming aware of the violation. 7 Industrial User Pretreatment Permit (IUP) PART II General Conditions 3. Test Procedures Test procedures for the analysis of pollutants shall be performed in accordance with the techniques prescribed in 40 CFR part 136 and amendments thereto unless specified otherwise in the monitoring conditions of this permit. 4. Additional Monitoring by Permittee If the permittee monitors any pollutant at the location(s) designated herein more frequently than required by this permit, using approved analytical methods as specified above, the results of such monitoring shall be submitted to the Control Authority and/or Municipality. The Control Authority and/or Municipality may require more frequent monitoring or the monitoring of other pollutants not required in this permit by written notification. 5. Duty to Comply The permittee must comply with all conditions of this permit. Any permit noncompliance constitutes a violation of the Control Authority and/or Municipality Sewer Use Ordinance and is grounds for possible enforcement action. 6. Duty to Mitigate - Prevention of Adverse Impact The permittee shall take all reasonable steps to minimize or prevent any discharge in violation of this permit which has a reasonable likelihood of adversely affecting human health,the POTW,the waters receiving the POTW's discharge,or the environment. 7. Facilities Operation, Bypass The permittee shall at all times maintain in good working order and operate as efficiently as possible, all control facilities or systems installed or used by the permittee to achieve compliance with the terms and conditions of this permit. Bypass of treatment facilities is prohibited except when approved in advance by the Control Authority and/or Municipality. Bypass approval shall be given only when such bypass is in compliance with 40 CFR 403.17. 8. Removed Substances Solids, sludges, filter backwash, or other pollutants removed in the course of treatment or control of wastewaters shall be disposed of in a manner such as to prevent any pollutants from such materials from entering the sewer system. The permittee is responsible for assuring its compliance with any requirements regarding the generation, treatment, storage, and/or disposal of"Hazardous waste" as defined under the Federal Resource Conservation and Recovery Act. 9. Upset Conditions An "upset" means an exceptional incident in which there is an unintentional and temporary noncompliance with the effluent limitations of this permit because of factors beyond the reasonable control of the permittee. An upset does not include noncompliance to the extent caused by operational error, improperly designed or inadequate treatment facilities, lack of preventative maintenance,or careless or improper operations. An upset may constitute an affirmative defense for action brought for the noncompliance. The permittee has the burden of proof to provide evidence and demonstrate that none of the factors specifically listed above were responsible for the noncompliance. 10. Right of Entry 8 Industrial User Pretreatment Permit (IUP) PART II General Conditions The permittee shall allow the staff of the State of North Carolina Department of Environment and Natural Resources, Division of Water Resources,the Regional Administrator of the Environmental Protection Agency, the Control Authority and/or Municipality, and/or their authorized representatives,upon the presentation of credentials: 1. To enter upon the permittee's premises where a real or potential discharge is located or in which records are required to be kept under the terms and conditions of this permit; and 2. At reasonable times to have access to and copy records required to be kept under the terms and conditions of this permit;to inspect any monitoring equipment or monitoring method required in this permit;and to sample any discharge of pollutants. 11. Availability of Records and Reports The permittee shall retain records of all monitoring information, including all calibration and maintenance records as well as copies of reports and information used to complete the application for this permit for at least three years. All records that pertain to matters that are subject to any type of enforcement action shall be retained and preserved by the permittee until all enforcement activities have concluded and all periods of limitation with respect to any and all appeals have expired. Except for data determined to be confidential under the Sewer Use Ordinance, all reports prepared in accordance with terms of this permit shall be available for public inspection at the Control Authority and/or Municipality. As required by the Sewer Use Ordinance, effluent data shall not be considered confidential. 12. Duty to Provide Information The permittee shall furnish to the Director of Public Works or his/her designees, within a reasonable time, any information which the Director, his/her designee, or the Division of Water Resources may request to determine whether cause exists for modifying, revoking and reissuing, or terminating this permit or to determine compliance with this permit. The permittee shall also furnish,upon request,copies of records required to be kept by this permit. 3. Signatory Requirements All reports or information submitted pursuant to the requirements of this permit must be signed and certified by the Authorized Representative as defined under the Sewer Use Ordinance. If the designation of an Authorized Representative is no longer accurate because a different individual or position has responsibility for the overall operation of the facility, or overall responsibility for environmental matters for the company, a new authorization satisfying the requirements of this section must be submitted to [POTW Director]prior to or together with any reports to be signed by an authorized representative. 14. Toxic Pollutants If a toxic effluent standard or prohibition(including any schedule of compliance specified in such effluent standard or prohibition) is established under Section 307(a) of the Federal Clean Water Act for a toxic pollutant which is present in the discharge and such standard or prohibition is more stringent than any limitation for such pollutant in this permit, this permit may be revised or modified in accordance with the toxic effluent standard or prohibition and the permittee so notified. 15. Civil and Criminal Liability Nothing in this permit shall be construed to relieve the permittee from civil or criminal penalties for noncompliance. 9 Industrial User Pretreatment Permit (IUP) PART II General Conditions 16. Federal and/or State Laws Nothing in this permit shall be construed to preclude the institution of any legal action or relieve the permittee from any responsibilities, liabilities, or penalties established pursuant to any applicable Federal and/or State law or regulation. 17. Penalties The Sewer Use Ordinance of the Control Authority and/or Municipality provides that any person who violates a permit condition is subject to a civil penalty not to exceed $25,000 dollars per day of such violation. Under state law, (NCGS 143-215.6B), under certain circumstances it is a crime to violate terms, conditions, or requirements of pretreatment permits. It is a crime to knowingly make any false statement,representation,or certification in any record or other document submitted or required to be maintained under this permit, including monitoring reports or reports of compliance or noncompliance. These crimes are enforced at the prosecutorial discretion of the local District Attorney. 18. Need to Halt or reduce not a Defense It shall not be a defense for a permittee in an enforcement action that it would have been necessary to halt or reduce the permitted activity to maintain compliance with the conditions of the permit. 19. Transferability This permit shall not be reassigned or transferred or sold to a new owner, new user, different premises,or a new or changed operation without approval of the Town. 20. Property Rights This permit does not convey any property rights in either real or personal property, or any exclusive privileges, nor does it authorize any injury to private property or any invasion of personal rights,nor any infringement of Federal, State or local laws or regulations. 21. Severability The provisions of this permit are severable and, if any provision of this permit or the application of any provision of this permit to any circumstance is held invalid, the application of such provision to other circumstances and the remainder of this permit shall not be affected thereby. 22. Permit Modification, Revocation, Termination This permit may be modified, revoked and reissued or terminated with cause in accordance to the requirements of the Control Authority and/or Municipality Sewer Use Ordinance and North Carolina General Statute or implementing regulations. 23. Re-Application for Permit Renewal The permittee is responsible for filing an application for reissuance of this permit at least 180 days prior to its expiration date. 24. Dilution Prohibition The permittee shall not increase the use of potable or process water or in any other way attempt to dilute the discharge as a partial or complete substitute for adequate treatment to achieve compliance with the limitations contained in this permit. 10 Industrial User Pretreatment Permit (IUP) PART II General Conditions 25. Reports of Changed Conditions The permittee shall give notice to the Control Authority and/or Municipality of any planned significant changes to the permittee's operations or system which might alter the nature,quality,or volume of its wastewater at least 180 days before the change. The permittee shall not begin the changes until receiving written approval from the Control Authority and/or Municipality. Also see Part II,30 below for additional reporting requirements for spill/slug issues. Significant changes may include but are not limited to (a) Increases or decreases to production; (b) Increases in discharge of previously reported pollutants; (c) Discharge of pollutants not previously reported to the Control Authority and/or Municipality; (d) New or changed product lines; (e) New or changed manufacturing processes and/or chemicals;or (f) New or changed customers. 26. Construction No construction of pretreatment facilities or additions thereto shall be begun until Final Plans and Specifications have been submitted to the Control Authority and/or Municipality and written approval and an Authorization to Construct(A to C)have been issued. 27. Reopener The permit shall be modified or, alternatively,revoked and reissued to comply with any applicable effluent standard or limitation for the control of any pollutant shown to contribute to toxicity of the WWTP effluent or any pollutant that is otherwise limited by the POTW discharge permit. The permit as modified or reissued under this paragraph may also contain any other requirements of State or Federal pretreatment regulations then applicable. 28. Categorical Reopener This permit shall be modified, or alternatively, revoked and reissued, to comply with any applicable effluent standard or limitation issued or approved under Sections 302(b)(2)(C)and(D), 304(b)(2), and 307(a)(2)of the Clean Water Act, if the effluent standard or limitation so issued or approved: 1.) Contains different conditions or is otherwise more stringent than any effluent limitation in this permit;or 2.) Controls any pollutant not limited in this permit. The permit as modified or reissued under this paragraph shall also contain any other requirements of the Act then applicable. 29. General Prohibitive Standards The permittee shall comply with the general prohibitive discharge standards in 40 CFR 403.5 (a) and(b)of the Federal pretreatment regulations. 30. Potential Problems The permittee shall provide protection from accidental and slug discharges of prohibited materials and other substances regulated by this permit. The permittee shall also notify the POTW immediately of any changes at its facility affecting the potential for spills and other accidental discharge, discharge of a non-routine, episodic nature, a non-customary batch discharge, or a slug load as defined in the Sewer Use Ordinance. 11 Industrial User Pretreatment Permit (IUP) PART II General Conditions Additionally, the permittee shall notify by telephone the Control Authority and/or Municipality immediately of all discharges that could cause problems to the POTW including any slug loadings as defined in the Sewer Use Ordinance. If the permittee experiences such a discharge, they shall inform the Control Authority and/or Municipality immediately upon the first awareness of the commencement of the discharge. Notification shall include location of the discharge, type of waste,concentration and volume if known and corrective actions taken by the permittee. A written follow-up report thereof shall be filed by the permittee within five (5) days, unless waived by the Control Authority and/or Municipality. 12 Industrial User Pretreatment Permit (IUP) PART III Special Conditions 1. Slug/Spill Control Measures In addition to the requirements in Part II, 30, the Permittee shall complete installation and/or commence implementation, operation, and/or maintenance of the following specific protection Measures, Activities, Plans. Etc. (Items without specific completion dates, or marked as "Continuous." must be performed for the entire duration of the permit): Required Completion/ Implementation Description of Measure, Activity, Plan, etc. Date Case Farms has a slug/spill plan in place, which includes a call sheet system in order to inform POTW in the event of a slug/ spill event. The slug spill/plan is located in the safety director's office at Case Farms and has been reviewed by POTW. The permittee shall provide updates to the Control Authority as required by Part II, 30, of this IUP. Modifications to the measures shall be approved by the Control Authority prior to installation/implementation. If a measure fails, the Control Authority shall be notified within 24 hours. 2. Sludge Management Plan Ninety days prior to the initial disposal of sludge generated by any pretreatment facility, the permittee shall submit a sludge management plan to the Control Authority. Modifications to the flow metering equipment shall be approved by the Control Authority prior to installation. If a required flow measurement device fails, the Control Authority shall be notified within 24 hours. 3. Flow Measurement Requirements (For SIUs currently without discharge flow meters) a.) Temporary Flow Measurement Method Until such time as discharge flow measurement devices for individual regulated pipes are required by the Control Authority, the permittee shall record the water meter reading providing water to the facility at the beginning and end of each composite sample collection time period, 13 Industrial User Pretreatment Permit (IUP) PART III Special Conditions convert this to an estimate of the daily discharge flow for each pipe, and report this value on the discharge monitoring report form. 4. Certified Laboratory Analysis Pollutant analysis shall be performed by a North Carolina Division of Water Resources Certified Laboratory that is certified in the analysis of the pollutant in wastewater. 5. Certified Operator Pursuant to Chapter 90A-44 of North Carolina General Statutes, and upon classification of the facility by the Certification Commission, the permittee shall employ a certified wastewater pretreatment plant operator in responsible charge (ORC) of the wastewater treatment facilities. Such operator must hold a certification of the type and grade equivalent to, or greater than the classification assigned to the wastewater treatment facilities by the Certification Commission. The permittee must also employ a certified backup operator of the appropriate type and grade to comply with the conditions of Title 15A, Chapter 8A .0202. The ORC of the facility must visit the wastewater facility as required; must properly manage and document daily operation and maintenance of the facility; and must comply with all other conditions of Title 15A, Chapter 8A .0202. The permittee shall submit a letter designating the operator in responsible charge to the Certification Commission or their designee within thirty days after facility classification. 14 IUP Synopsis A. IUP Basic Information Receiving POTW name: POTW NPDES#: Catawba River Pollution Control Facility NC0026573 IUP name: IUP Number: Case Farms 1098 IUP Effective date: Pipe Numbers,list all regulated pipes: May 31, 2020 01 IUP expiration date: IUP 40 CFR#,if applicable: May 31, 2025 N/A B. IUP Survey&Application form Attach a completed copy of the Industrial User Wastewater Survey& Application Form (see appendix 6-A) C. IU Inspection form Attach a copy of an Industrial User Inspection Form (see chapter 7) completed by the Control Authority within the past 12 months. D. RATIONALE FOR LIMITATIONS: As listed on the IUP Limits Page(s), PART I, Section F of the IUP. RATIONALE#1: Review of IU Monitoring Data,with no Over Allocation situation: The following pollutants were assigned numerical limits in this IUP based on a review of monitoring data for the permittee to determine what ranges of concentrations are currently being discharged. To account for sample variability a factor was applied to the monitoring data to determine the permit limit. Permit limits assigned by the Local IUP Control Authority can not results in an Over Allocation situation for any pollutants. BOD, COD, pH, TSS, Oil & Grease, Flow, 1 IUP Synopsis RATIONALE#2a: Categorical Industrial Limits, with no Over Allocation situation: Check here if Combined Wastestream Formula (CWF) or other categorical limits calculations were used. If used, Please attach calculations: (see CWF Spreadsheet, Appendix 6-F) Were used (attach calculations) Were not used X 2 Industrial User Wastewater SurveyRECEIVED & Permit Application JAN 21 2020 COVER PAGE NCDZQ/DWR/NPDES Company Name:Case Farms Name of responsible person on site at the facility authorized to represent the Name of alternative on site person familiar with the day to day operations, company in official dealings with the Sewer Authority and/or the City. environmental permitting requirements, monitoring, record keeping, and David McHugh data management.. William Pate Title Maintenance Manager Years with firm Title Project Manager Years with firm 9 I2 Phone#828-390-2470 Fax# Phone#828-430-1172 Fax# Physical street address of facility 121 Rand Street Official mailing address,if different.PO Box 308 City Morganton State NC Zip 28655 City Morganton State NC Zip 28680 The information provided by you on this questionnaire serves two functions: 1. The information is used to determine if your facility needs an Industrial User Pretreatment Permit (IUP) for the discharge of wastewater to the local sewer. 2. If an Industrial User Pretreatment Permit (IUP) is required, this survey serves as the application for an Industrial User Pretreatment Permit(IUP). Requests for confidential treatment of information provided on this form shall be governed by procedures specified in 40 CFR Part 2. In accordance with Title 40 of the Code of Federal Regulations Part 403, Section 403.14 and the Local Sewer Use Ordinance (SUO), information and data provided in this questionnaire which identifies the content, volume and frequency of discharge shall be available to the public without restriction. This is to be signed by an authorized official of your firm,as defined in the Local Sewer Use Ordinance or the NC Model Sewer Use Ordinance,Section 1.2,after completion of this form. I certify under penalty of law that this document and all attachments were prepared under my direction or supervision in accordance with a system designed to assure that qualified personnel properly gather and evaluate the information submitted. Based upon my inquiry of the person or persons who manage the system, or those persons directly responsible for gathering the information, the information submitted is, to the best of my knowledge and belief, true, accurate and complete. I am aware that there are significant penalties for submitting false information, including the possibility of fine and/or imprisonment for knowing violat' ns. ' day Signature of Authorized Representative Date listed above (seal if applicable) Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 1 of 228 Industrial User Wastewater Survey & Permit Application 1. Provide a brief narrative description of the type of business, manufacturing processes, or service activities your firm conducts at this site. Poultry slaughter/process packing 2. List the primary products produced at this facility: Poultry 3. List raw materials and process additives used: 4. Are biocides added to any water discharged to the POTW, if yes describe: Yes No x 5. Describe weekly production schedule, including shifts worked per day, employees per shift, and primary operation during shift. The plant is scheduled for production days per week with an occasional Saturday schedule. Third Shift Production First Shift Production Second Shift Sanitation 6. Production process is: Check, if all continuous 100 Check, if all batch If both please enter, % continuous= % % Batch = Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 2 of 228 Industrial User Wastewater Survey & Permit Application 7. Does production vary significantly(+-20 %)by season. Describe. Yes No R 8. Are any significant (+- 20 %) changes in production that will affect wastewater discharge expected in the next 5 years. If yes,please describe. Yes No X 9. List all current waste haulers. Give name, address, phone numbers, volume and materials hauled off. Valley Proteins 1309 Industrial Drive Fayetteville, NC 28301 10. Attach a copy of laboratory analyses performed in the last year on the wastewater discharge(s) from your facilities. Summarize data on the attached Data Summary Form. See attachment 11. Attach sketch or schematic showing sampling points and all connections to the sewer. See attachment 12. Complete the Wastewater Pollutants Checklist attached to this Survey. Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\1UP Permit Application 2019.doc Revision date: 12/30/97 Page 3 of 228 Industrial User Wastewater Survey & Permit Application Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\201 8 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 4 of 228 Industrial User Wastewater Survey & Permit Application 13. Do you have, or have you ever applied for, been issued, or been denied an NPDES permit to discharge to the surface waters or storm sewers of North Carolina? If yes, list all other NPDES permits, permit numbers, dates, and names used to apply for them, or reason denied. If yes: Permit,#,date,applicant name x NCG060392,7-9-2019,Case Farms Processing Inc. Yes If yes: Permit,#,date,applicant name No 14. Do you have, or have you ever applied for or been issued an Industrial User Pretreatment Permit (IUP) to discharge wastewater to the sewer collection system. If yes, list all other IUP permits, permit numbers, dates, and names used to apply for them. If yes: Permit,#,date,applicant name X Yes 1098,11-9-2018,Case Farms If yes: Permit,#,date,applicant name No 15. Do you have, or have you ever applied for or been issued any other Environmental Permits (for example; air, RCRA, groundwater, stormwater, general, Non-Discharge, septic tank, etc.). If yes, list all other permits,permit numbers, dates, and names used to apply for them. If yes: Permit type,#,date,applicant name x Air emissions,NCDENR 03248R11,Case Farms Yes If yes: Permit type,#,date,applicant name EPA hazardous waste,small waste generator,NCD982165524,Case Farms NO If yes: Permit type,#,date,applicant name 16. Is a Spill Prevention Control and Countermeasure (SPCC) Plan prepared for this facility? Yes x No 17. Is a Spill /Slug Control Plan required by the POTW, prepared for this facility? Yes x No Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 5 of 228 Industrial User Wastewater Survey & Permit Application 18. Do you have any underground storage tanks at your facility? If yes, list contents and volume of each tank. Yes No x 19. Do you have any above ground storage tanks at your facility? If yes, for each tank, list the contents, volume, whether the tank has any spill prevention or containment devices, such as dikes, and procedures for draining any containment devices. Yes x #of Tanks 5 No Diesel fuel 10,000 gallons Diked Waste oil 500 gallons Diked Hydraulic oil 250 gallons Motor oil 250 gallons Waste H2O 5000 gallons Title: lU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\NP Permit Application 2019.doc Revision date: 12/30/97 Page 6 of 228 Industrial User Wastewater Survey & Permit Application PART II, Water Supply, Use, & Disposal Worksheet: Water Used for: Water Avg. Max. M E Disposal Avg. Max. M E gal/day gal/day e st gal/day gal/day e st Source(s) a i Method(s) a i s m s m u at u at re e re e d d d d (see Source List below) (see Disposal List below) 1. Process water City supply 1,072,000 Sanitary sewer w/ pretreatment 2. Washdown water City supply 300,000 Sanitary sewer w/ pretreatment 3. Water into product 4. Air Quality Permitted units 5. Domestic -toilets, drinking,cafe City supply 17,000 Sanitary sewer w/ pretreatment 6. Cooling water,Process NON-Contact City supply 28,000 Sanitary sewer w/ pretreatment 7. Boiler/Cooling tower blowdown City supply 48000 Sanitary sewer w/ pretreatment 8. Cooling water, HVAC 9. Other: Totals => 1465000 Totals => Typical Water Sources: Possible Water Disposal Methods 1. City/Public supply 1. Sanitary sewer, with pretreatment 2. Private wells, drinking 2. Sanitary sewer, without pretreatment 3. Groundwater remediation wells 3. Storm sewer 4. Private ponds 4. Surface waters of NC 5. Surface waters of NC,please identify 5. Evaporation 6. Include others if applicable 6. Land applied 7. To groundwater Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 7 of 228 8. Septic Tank 9. Waste Haulers (identify) 10. Water into Product 11. Include others, if applicable Title: lU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 PermitUUP Permit Application 2019.doc Revision date: 12/30/97 Page 8 of 228 PART III, PRETREATMENT FACILITIES: Are there any pretreatment devices or processes used for treating wastewater before being discharged to the sewer? Check all that are present, and describe. No pretreatment facilities => 1. Flow equalization Aerated equalization => 100,000 G NON-Aerated equalization => Total volume of equalization (million gal.) => 2. Activated Carbon Yes No X Describe any, if present. 3. Activated Sludge Yes No x 4. Air Stripping Yes No x 5. Centrifugation Yes No 6. Chemical Precipitation Yes No X 7. Chlorination Yes No x 8. Cyanide Destruction Yes No X 9. Cyclone Yes No x 10. Dissolved Air Floatation Yes X No 11. Filtration Yes No 12. Flocculation Yes No 13. Grease Trap Yes X No 14. Grit Removal Yes x No 15. Ion Exchange Yes No X 16. Neutralize,pH adjust Yes X No 17. Other Biological Treatment Yes No 18. Ozonation Yes No X 19. Reverse Osmosis Yes No X 20. Screening Yes X No 21. Sedimentation Yes No 22. Septic Tank Yes No X 23. Silver Recovery Yes No X 24. Solvent Separation Yes No 25. Spill protection Yes X No List any others. Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 9 of 228 PART IV, CATEGORICAL INFORMATION: 1. When were operations started at this facility Facility start up date 1988 2. List all Standard Industrial Classification (SIC) codes for your facility. These may be found on State Unemployment forms, tax forms, accounting records, or from the Chamber of Commerce. 0251/1123 20 • 3. Has this facility ever been considered a Categorical Industrial User (CIU) as described by the Code of Federal Regulations (40 CFR)? If yes, give complete 40 CFR number=> No 4. Are any other facilities owned and/or operated by your company permitted as Categorical Industrial Users (CIUs) as described by the Code of Federal Regulations (40 CFR)? If yes please give name(s), location, and 40 CFR number. Yes No Title: LU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 PermitIUP Permit Application 2019.doc Revision date: 12/30/97 Page 10 of 228 PART IV, CATEGORICAL INFORMATION: (continued) 5. Check any activities listed below that are performed at your facility: Check 40 Industrial Activity Check FO Industrial Activity below CFR# below CFR# 467 Aluminum Forming x 432 Meat products 427 Asbestos Manufacturing 433 Metal finishing 461 Battery Manufacturing 464 Metal molding and casting 431 Builders paper&board mills 436 Mineral mining and processing 407 Canned&preserved fruits&veg. 471 Nonferrous Metal,Form&Powders 408 Canned&preserved seafood 421 Nonferrous Metals Manufacturing 458 Carbon black Manufacturing 414 OCPSF,Organic Chemicals,Plastics, 411 Cement Manufacturing &Synthetic Fiber Manufacturing 437 Centralized Waste Treatment 435 Oil&gas extraction 434 Coal Mining 440 Ore mining and dressing 465 Coil Coating 446 Paint formulating 468 Copper Forming 443 Paving and roofing materials Mfg. 405 Dairy products processing 455 Pesticide Manufacturing 469 Electrical,electronic components 419 Petroleum Refining 413 Electroplating 439 Pharmaceutical Manufacturing 457 Explosives Manufacturing 422 Phosphate Manufacturing 412 Feedlots 459 Photographic supplies 424 Ferro allay Manufacturing 463 Plastics molding and forming 418 Fertilizer Manufacturing 466 Porcelain enameling 464 Foundries,Metal Mold&Casting 430 Pulp,paper,and paperboard 426 Glass Manufacturing 428 Rubber Manufacturing 406 Grain mills 417 Soap&Detergent Manufacturing 454 Gum&Wood Chemicals Mfg. 423 Steam Electric power Generation 460 Hospitals 409 Sugar processing 447 Ink formulating 410 Textile Mills 415 Inorganic chemical Manufacturing 429 Timber products processing 420 Iron&Steel Manufacturing 442 Transportation Equipment Cleaning 425 Leather Tanning&Finishing Others Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 11 of 228 Wastewater Pollutant Checklist Chemical Name EPA Check if Check if Check if Check if Concentration Storet Present at Absent at Present in Absent in in Discharge, Code Facility Facility Discharge Discharge if Known (mg/1) Acid Extractable Organics 2-Chlorophenol 34586 X X 2,4-Dichlorophenol 34601 X X 2,4-Dimethylphenol 34606 X X 2,4-Dinitrophenol 34616 X X 2-Methyl-4,6-dinitrophenol 34657 X X 4-Chloro-3-methylphenol 34452 X X 2-Nitrophenol 34591 X X 4-Nitrophenol 34646 X X Pentachlorophenol 39032 X X Phenol 34694 X X 2,4,6-Trichlorophenol 34621 X X Base Neutral Organics 1,2,4-Trichlorobenzene 34551 X X 1,2-Dichlorobenzene 34536 X X 1,2-Diphenylhydrazine 34346 X X 1,3-Dichlorobenzene 34566 X X 1,4-Dichlorobenzene 34571 X X 2,4-Dinitrotoluene 34611 X X 2,6-Dinitrotoluene 34626 X X 2-Chloronaphthalene 34581 X X 3,3-Dichlorobenzidine 34631 X X 4-Bromophenyl phenyl ether 34636 X X 4-Chlorophenyl phenyl ether 34641 X X Acenaphthene 03405 X X Acenaphthylene 34200 X X Anthracene 34220 X X Benzidine 39120 X X Benzo(a) anthracene 34526 X X Benzo(a)pyrene 34247 X X Benzo (b) fluoranthene 34230 X X Benzo(ghi) perylene 34521 X X Benzo(k) fluoranthene 34242 X X Bis(2-chloroethoxy) methane 34278 X X Bis(2-chloroethyl) ether 34273 X X Bis(2-chloroisopropyl) ether 34283 X X Bis(2-ethylhexyl) phthalate 39100 X X Butyl benzyl phthalate 34292 X X Chrysene 34320 X X Di-n-butyl phthalate 39110 x X Title: EU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 12 of 228 Wastewater Pollutant Checklist Chemical Name EPA Check if Check if Check if Check if Concentration Storet Present at Absent at Present in Absent in in Discharge, Code Facility Facility Discharge Discharge if Known (mg/1) Base Neutral Organics (continued) Di-n-octyl phthalate 34596 X X Dibenzo (a,h) anthracene 34556 X X Diethyl phthalate 34336 X X Dimethyl phthalate 34341 X X Fluoranthene 34376 X X Fluorene 34381 X X Hexachlorobenzene 39700 X X Hexachlorobutadiene 34391 X X Hex achlorocyclopentadiene 34386 X X Hexachloroethane 34396 X X Indeno(1,2,3-cd)pyrene 34403 X X Isophorone 34408 X X N-nitroso-di-n-propylamine 34428 X X N-nitrosodimethylamine 34438 X X N-nitrosodiphenylamine 34433 X X Naphthalene 34696 X X Nitrobenzene 34447 X X Phenanthrene 34461 X X Pyrene 34469 X X Metals Aluminum 01104 X X Antimony 01097 X X Arsenic 01002 X X Beryllium 01012 X X Cadmium 01027 X X Chromium 01034 X X Copper 01042 X X Lead 01051 X X Mercury 71900 X X Molybdenum 01062 X X Nickel 01067 X X Selenium 01147 X X Silver 01077 X X Thalium 00982 X X Zinc 01092 x X Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 13 of 228 Wastewater Pollutant Checklist Chemical Name EPA Check if Check if ' Check if Check if Concentration Storet Present at Absent at Present in Absent in in Discharge, Code Facility Facility Discharge Discharge if Known (mg/1) Other Inorganics Barium 01007 X X Chloride s 00940 _ X X Cyanide 00720 X - X Fluoride 00951 x X Purgeable Volatile Organics 1,1,1-Trichloroethane 34506 X X 1,1,2,2-Tetrachloroethane 34516 X X 1,1,2-Trichloroethane 34511 X X 1,1-Dichloroethane 34496 X X 1,1-Dichloroethylene 34501 X X 1,2-Dichloroethane 34531 X X 1,2-Dichloropropane 34541 X X 2-Chloroethyl vinyl ether 34576 X X Acrolein 34210 _ X X Acrylonitrile 34215 X X Benzene 34030 X X Bromodichloromethane 32101 X X Bromoform 32104 X X Bromomethane 34413 X X Carbon tetrachloride 32102 X X Chlorobenzene 34301 X X Chloroethane 34311 X X Chloroform 32106 X X Chloromethane 34418 X X cis 1,3-Dichloropropene 34704 X X Dibromochloromethane 32105 X X Ethylbenzene 34371 X X Methylene chloride 34423 X X Tetrachloroethylene 34475 X X Toluene 34010 X X trans 1,3-Dichloropropene 34699 X X trans-1,2-Dichloroethylene 34546 X X Trichloroethylene 39180 X X Trichlorofluoromethane 34488 X, X Vinyl chloride 39175 X X Others Xylene x X Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 14 of 228 Data Summary Form Catawba <= Receiving POTW River NC0026573 <= Receiving NPDES # <= Specific Sample Location! i.e., Give IU Name, IUP#, and/or pipe# BOD TSS Ammonia I Laboratory performing analysis => t Laboratory Method Detection Limits => I Notes => t E c = Flow Title: N Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 15 of 228 Sample ID, or 1 Notes about Sample M = Metered Conc. Results Conc. Results Conc. Results Count E = Estimated from Lab from Lab from Lab t 1 1 1 1 1 ( t mgd gal/day <? mg/1 <? mg/1 ‹? mg/1 1 2 3 4 5 6 _ 7 8 9 10 11 12 etc TNS => Total number of samples => Title: IU Wastewater Survey & Permit Application File name: S:\.Morg Maint-Supervisor\Ivly Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 16 of 228 Max. value => Maximum data value (mg/1) =>I Avg. (use 1/2 BDL) => Avg. data value, Include BDL values as 1/2 detection limit=> Data Summary Form Catawba River <= Receiving POTW NC0026573 <= Receiving NPDES # <= Specific Sample Location! i.e., Give IU Name, IUP#, and/or pipe# Arsenic Copper Chromium Cadmium COD Copper Lab => MDL=> Notes => Sample Date Sample Conc. Results Conc. Results Conc. Results Conc. Results Conc. Results Conc. Results ID or Collected from Lab from Lab from Lab from Lab from Lab from Lab Count <? mg/1 <? mg/1 <? mg/1 <? mg/1 <? mg/1 <? mg/1 1 2 3 4 5 6 7 8 9 10 11 12 etc TNS => Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maim-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 17 of 228 Max. Value => Avg. (use 1/2 BDL) => Data Summary Form Catawba River <= Receiving POTW NC0026573 <= Receiving NPDES # <= Specific Sample Location! i.e., Give IU Name, IUP#, and/or pipe # Cyanide Lead Mercury Nickel Silver Zinc Lab => MDL => Notes => Sample Date Sample Conc. Results Conc. Results Conc. Results Conc. Results Conc. Results Conc. Results ID or Collected from Lab from Lab from Lab from Lab from Lab from Lab Count <? mg/1 <? mg/I <? mg/1 <? mg/1 <? mg/1 <? mg/1 1 2 3 4 5 6 7 8 9 10 11 12 etc TNS => Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maim-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 18 of 228 Max. Value => Avg. (use1/2 BDL) => Data Summary Form <= Receiving POTW Catawba River <= Receiving NPDES # NC0026573 <= Specific Sample Location! i.e., Give IU Name, IUP#, and/or pipe # Other Other Other Other Other Other Lab => MDL => Notes => Sample Date Sample Conc. Results Conc. Results Conc. Results Conc. Results Conc. Results Conc. Results ID or Collected from Lab from Lab from Lab from Lab from Lab from Lab Count <? mg/1 <? mg/1 <? mg/I <? mg/1 <? mg/1 <? mg/I 1 2 3 4 5 6 7 8 9 10 11 12 etc TNS => Title: Hi Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 19 of 228 Max. Value=> Avg. (use1/2 BDL) => Title: IU Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 20 of 228 Industrial User Wastewater Survey & Permit Application Part V, Waste Reduction Information : State Pretreatment Rule 15A NCAC 2H.0916 (c)(1)(M) requires Significant Industrial Users to include a description of current and projected waste reduction (pollution prevention) activities. The codes listed are standard EPA codes found on Toxic Release Inventory and other environmental forms. Please check all applicable codes for your facility related to wastewater discharge. Current Projected Code Description X W 13 Improved maintenance scheduling recordkeeping, or procedures W14 Changed production schedule to minimize equipment and feedstock changeovers W 19 Other changes in operating practices (explain briefly in comments) W21 Instituted procedures to ensure that materials do not stay in inventory beyond shelf-life W22 Began to test outdated material-continue to use if still effective W23 Eliminated shelf-life requirements for stable materials X W24 Instituted better labeling procedures W25 Instituted clearinghouse to exchange materials that would otherwise be discarded W29 Other changes in Inventory control (explain briefly in comments) W31 Improved storage or stacking procedures W32 Improved procedures for loading, unloading and transfer operations W33 Installed overflow alarms or automatic shutoff valves W34 Installed secondary containment X W35 Installed vapor recovery systems X W36 Implemented inspection or monitoring program of potential spill or leak sources X W39 Other spill and leak prevention (explain briefly in comments) W41 Increased purity of raw materials W42 Substituted raw materials W49 Other raw material modifications (explain briefly in comments) X W51 Instituted recirculation within a process Title: IU Wastewater Survey&Permit Application File name: S:\Morg Maint-Supervisor\Ivly Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\IUP Permit Application 2019.doc Revision date: 12/30/97 Page 21 of 18 Industrial User Wastewater Survey & Permit Application Current Projected Code Description X W52 Modified equipment, layout, or piping W53 Use of a different process catalyst W54 Instituted better controls on operating bulk containers to minimize discarding of empty containers X W55 Changed from small volume containers to bulk containers to minimize discarding of empty containers W58 Other process modifications (explain briefly in comments) W59 Modified stripping/cleaning equipment W60 Changed to mechanical stripping/cleaning devices (from solvents or other materials) W61 Changed to aqueous cleaners ( from solvents or other materials) W62 Reduced the number of solvents used to make waste more amenable to recycling W63 Modified containment procedures for cleaning units W64 Improved draining procedures W65 Redesigned parts racks to reduce dragout W66 Modified or installed rinse systems W67 Improved rinse equipment design W68 Improved rinse equipment operation W71 Other cleaning and degreasing operation (explain briefly in comments) W72 Modified spray systems or equipment W73 Substituted coating materials used W74 Improved application techniques W75 Changed from spray to other system W78 Other surface preparation and finishing (explain briefly in comments) W81 Changed product specifications W82 Modified design or composition of product W83 Modifiedpackaging W89 Other product modifications (explain briefly in comments) W99 Other(specify in comments ) Comments (Please list corresponding code) Title: Ili Wastewater Survey & Permit Application File name: S:\Morg Maint-Supervisor\My Documents\William.Case\City of Morganton\Waste Water Permit\2018 Permit\NP Permit Application 2019.doc Revision date: 12/30/97 Page 22 of 228 ..- .......--...-....„.,... .--....----....... 11'. ' 4CLIA.111:410 1111 OM--•••• •-..• 9 T,Tr arm WM.11100....-•••.. . 1.. 71/1100.1 .1, FilliFiri ........... "VI:Mr" NM 10110 NI .0 IMMO .0 •-• , *Arra MO WM IT NNE MIN-..-... ... *44 01211 AMOS. ....--- .44, ZI1 WW1 WS SS i NOS MON .... - _ MI WO 11114•-...rt- - le ale=..--•- ...az -o k....._ , . 1)---........ / -0 i *"..--- • armuya am ot ...• o'.., all".WWI.00 VOUVII -i• 440. / .--. / .. / // I f/ / on /4/0/ .. . / / Z........... -____ kwil. .....-----itzti. : ,., _...„..."•41: ::81.41:7 ; , ...sairilM 4. .;"•••;. .. ----- "--- '.-- -4 ,, ,- -------„.:'_-,-,!;,'-'rnii IIII,••W 7. : ,talliki • my . ,,,:.....sitiiriciri,„•-.74.5-,„ ar ti."..----+Allie ...ift• r ii.,;:se, ,lir .'if7r4riftlfft...... •••••;--... \ -Zroe.,‘,,,nfterlive' "1"-42-0 • ; .7 - :A f: N, . . i if - . -7,--• t r ... • . , • • 1 g 1.„ TAY .' ' /4 / / • .:.. , 5 • \ / - Atealrith Waage., .. , .'• '.. • \ I I (-__ 4'4-044,14,.., jr/ , . 1 .. v , ........., .,..:, 1 . v i i..... ..,... L . l'Afgar ... ..1.4 Ifeellif 4. .. , Ir.. iiiii. .., .46. -i i of- li —...... "..../. . / . 'N`V• - --.-• , /411**/ i . •. ii.,.. i*". " -• .,.. ._..../ _ 1,••••••....__,.. felbi _ wilii14111111 .• .• , 5 --weal• Ai ,i " • .4".....40.1„ I -- ..... • 44 N. .... , , .... _ IRE---- a / ..,....••'.'..-'-. .' MAIM*WNW SINI / Ill fil SIM.Mr/NATO Sat ID • . ...-. . .........•......s.........•••... .......---..--..----..- ..........—--....--.-............-- --..... - - -.........._.____-_ ._-..___ -.__ .-.---,--,-- - . o 1 '1-' I -T. � s uturs a� `ate �1 ( ♦ �� \ or °rricit. pR a'a' &-kr / x SN'Z' l�) OnER1� • r �1 I o-� ,r F �� - ss ----..„. —/ ,..,4". ,,j i\/ \, \ t, �� • \ \ \\ &// m 1 kt )r......:.........„ _, , __.- ,,, 4' 4, ,..- \ i \\ \ \ il M ir // / i. \ \ \ 1 • m - \ \ \ \ ' kV 4t. -1. •kk •is-...5.0_:____::-.:..-_1 .74r---------li "pH. . ---.-.1------ , , \ , 1 f • k rt ./ / •I 1 t V 1 % . J "\---"Ci; / ." 1 lf.., /_,1 { y ) '\ //A •• 1 1 . 11 � I .A // n i a n. / / J Ica / 1 ! / 1 !� i I I I 1 ! 1 1 e 1J / 1 1 �� 1 1 f I� ! � t } p 11 // I 1 1 1 1m R ! r!-n A-F / 01/ I I I m / rnr J I I /'' / i 11 Tom``0 i 1 j ....„ „ , 1 /1 // /i "sissoli w/ 1 1 1 11 /• 4 I / / U? 1 1 1 1 111 1 1 miiii ,1 a o alI /ii //// ,i 1/, ,/ , , , , ,„ ,,, 11 1 1 , .\\ g, • 1 /./ ,...._,0 ____ .______._, . - /___,,,/ ,_,......_ .......„..7.0 ,„ _ 1 1 1 1 , i rry . 11(.4.8'7 1 1 / , , / is. // l6b 1 \ // __y ____4_ 1 i .t i i .ti $va,a`°„xw-r --....� ,' O_.a,Inc<'°n'°c 13.1 :: !jt ex L , IllI • ,�r Ye,x, I. l o iI iiIlIII . ..,.;.. . ,...: 03110 ..r ) ! t1 •.cwo x mints.PAM v vna C"7 I [. �' ant.! y /ricai -� 11001 ,�_J I • r ,FLI ,_0....=.,a,_6_, _: " tt noa * K u • I�NMI Ell MINI .s, WON I' Fil" D it .::J. aJi alwtr: I agB Bidets �� ir.tnr[D ram tw F..INN. n..,mLL w v " !imam MIL [fOQi Umt OM .uw, Or GFPO I N. n.-,7-+[ OW NI ew u.MN.,4v O*nv•r. E .... ;v . y� = "" r.nr .mm v.. w ns• au�i" o,... """S r z r tia.�wa ww.e.w. Whom rm. en...r a. e0xmq.a.eu r80.1•Weft!•10 an r Mp NG spa•Son Ow tap tank MIlwassrni Jan, Wert OW NEN KM m NUaw.a. for Siasaby Flic S.ST£JS IN7ERNArONAL LLC 550 OAK INDUSTRIAL LANE. SURF r r....,.,.w,..•• ere ta.+r., =� CASE FARMS '� w GIMMINC. GEORQA 30041 ,�y� NiL ilopot PHONE: (770)534-3681 ••�".`?.w �>� MORGANTON, NC ""' ; S terns International _ FL: (770) 7Y3t rern�s.corn er.r�� r�i�+.+..ee,rr H EMAIL: Ir,i0 RCa -,--p,,, " .t�f... PROCESS & ++i.,.• INSTRUMENTATION DRAWING 1QrYS032PP10 121 Rand street Morganton,NC. 28655 Phone:828.438.6900 Fax:828.437.5205 dmchugh@casefarms.com N 141 Monthly waste water testing To From Tim Arney Gary Rutherford Morganton Pretreatment Coordinator Wastewater Manager Phone number: 828.438-5376 Case farms,LLC Sample Date: 11-7-19 Urgent For Review Please Comment Please Reply Message: Flow— 1,320,956 PH — 7.88 l3O© 1.3 a/ X 630 X g,3Y = ‘, 9 V/ 655 Cbo i,3a/ x 74" x 7.3y ; 9; 153 ta5 Blue Ridge Labs PO Box 2940 Lenoir, NC 28645 828-728-0149 blueridgelabslenoir@gmail.com Client : Case Farms PO Box 308 Morganton,NC 28680 Attention: Mr. Gary Rutheford Date Received: 07-Nov-19 Report Date: 26-Nov-19 Sample Date: 07-Nov-19 BRL#: BRL-2019-0925 Lab Sample ID: LSID-2019-03552 Client Sample ID: Case Farms Analysis Analysis Parameter Result MQL Unit Method Time Date Analyst BOD-5 day 630 2 mg/I SM 5210B 11/8/2019 WtrQtly Reported por ed By: S.J.J f son, D.R. Wessinger * Concentrations are below Minimum Quantification Limit except where noted. NC Laboratory Certificate No.275 Page 1 of 7 Blue Ridge Labs PO Box 2940 Lenoir, NC 28645 828-728-0149 blueridgelabslenoir@gmail.com Client : Case Farms PO Box 308 Morganton,NC 28680 Attention: Mr. Gary Rutheford Date Received: 07-Nov-19 Report Date: 26-Nov-19 Sample Date: 07-Nov-19 BRL#: BRL-2019-0925 Lab Sample ID: LS1D-2019-03553 Client Sample ID: Case Farms Analysis Analysis Parameter Result MQL Unit Method Time Date Analyst COD 740 20 mg/1 SM 5220D 1 1/25/2019 WtrQtly offt"— Reported By: 7 S.J.�nson,D.R. Wessinger * Concentrations are below Minimum Quantification Limit except where noted. NC Laboratory Certificate No.275 Page 2 of 7 Blue Ridge Labs PO Box 2940 Lenoir, NC 28645 828-728-0149 blueridgelabslenoir@gmail.com Client : Case Farms PO Box 308 Morganton,NC 28680 Attention: Mr. Gary Rutheford Date Received: 07-Nov-19 Report Date: 26-Nov-19 Sample Date: 07-Nov-19 BRL#: BRL-2019-0925 Lab Sample ID: LSID-2019-03554 Client Sample ID: Case Farms Analysis Analysis Parameter Result MQL Unit Method Time Date Analyst TSS 121 25 mg/1 2540D 1997 11:53 11/13/2019 KCJ Reported By: S.J.J son, D.R. Wessinger * Concentrations are below Minimum Quantification Limit except where noted. NC Laboratory Certificate No.275 Page 3 of 7 Blue Ridge Labs PO Box 2940 Lenoir,NC 28645 828-728-0149 blueridgelabslenoir@gmail.com Client : Case Farms PO Box 308 Morganton,NC 28680 Attention: Mr. Gary Rutheford Date Received: 07-Nov-19 Report Date: 26-Nov-19 Sample Date: 07-Nov-I9 BRL#: BRL-2019-0925 Lab Sample ID: LSID-2019-03555 Client Sample ID: Case Farms Analysis Analysis Parameter Result MQL Unit Method Time Date Analyst Fats,Oil&Grease 15.1 1 mg/1 5520E 2001 14:19 11/20/2019 KCJ Reported By: 1= ' 4 S.J. son,D.R.Wessinger * Concentrations are below Minimum Quantification Limit except where noted. NC Laboratory Certificate No.275 Pane 4 of 7 Blue Ridge Labs PO Box 2940 Lenoir,NC 28645 828-728-0149 blueridgelabslenoir@gmail.com Client : Case Farms PO Box 308 Morganton,NC 28680 Attention: Mr. Gary Rutheforcl Date Received: 07-Nov-I9 Report Date: 26-Nov-19 Sample Date: 07-Nov-19 BRL#: BRL-2019-0925 Lab Sample ID: LSID-2019-03556 Client Sample ID: Split Analysis Analysis Parameter Result MQL Unit Method Time Date Analyst BOD-5 day 440 2 mg/I SM 5210B 11/8/2019 WtrQtly Reported By: x? r � S.J.4thson,D.R. Wessinger * Concentrations are below Minimum Quantification Limit except where noted. NC Laboratory Certificate No.275 Page 5 of 7 Blue Ridge Labs PO Box 2940 Lenoir, NC 28645 828-728-0149 blueridgelabslenoir@gmail.com Client : Case Farms PO Box 308 Morganton, NC 28680 Attention: Mr. Gary Rutheford Date Received: 07-Nov-19 Report Date: 26-Nov-19 Sample Date: 07-Nov-19 BRL#: BRL-2019-0925 Lab Sample ID: LSID-2019-03557 Client Sample ID: Split Analysis Analysis Parameter Result MQL Unit Method Time Date Analyst COD ---_— —'_-- 730 20 mg/I SM 5220D ___---_-------- 11/25/2019 WtrQtly Reported By: or% S.J. 1 • on,D.R.Wessinger * Concentrations are below Mir imunr Quantification Limit except where noted. NC Laboratory Certificate No.275 Page 6 of 7 Blue Ridge Labs PO Box 2940 Lenoir, NC 28645 828-728-0149 blueridgelabslenoir@gmail.com Client : Case Farms PO Box 308 Morganton,NC 28680 Attention: Mr. Gary Rutheforcl Date Received: 07-Nov-19 Report Date: 26-Nov-19 Sample Date: 07-Nov-19 BRL#: BRL-2019-0925 Lab Sample ID: LSID-2019-03558 Client Sample ID: Split Analysis Analysis Parameter Result MQL Unit Method Time Date Analyst TSS 123 mg/I 2540D 1997 11:54 11/13/2019 KCJ Reported By: S.J.Jo on,D.R.Wessinger * Concentrations are below Minimum Quantification Limit except where noted. NC Laboratory Certificate No. 275 Page 7 of 7 WATER QUALITY LAB&OPERATIONS, INC. P.O. BOX 1167 BANNER ELK, NC 28604 (828)898-6277 CLIENT: BLUE RIDGE LABS LOGIN TIME: Annppp. : p n pnY 9c4.10 cnIVIF'I PR: CITY: LENOIR RECEIVED DATE: STATE: NC ZIP 28645 REPORTED DATE: 9-Dec-11 ID#: ANALYSIS :. LSID# IANALYsIsl. MQL's . UNITS ,.SAMPLE ANALYSIS INT. . :I RESULTS' : I LOCATION! .. DATE:..I .... ..I I I..... ' 1 1 1 I I COD 3506 20 20 MG/L 25-Nov-19 PI COD IP 1270 20 MG/L 25-Nov-19 PI COD CASE 740 20 MG/L 25-Nov-19 PI ICOD (SPLIT , 730 I 20 I MG/L I 125-Nov-19, PI I i 1 f I 1 I I I I COD 37501 80 I 20 1 MG/L I I25-Nov-19I PI I REPORTED BY: NC CERTIFIED LAB#544 P PALII IRPNH( 1_IR^ CI iPFR I.SfP WATER QUALITY LAB &OPERATIONS, INC. P.O. BOX 1167 BANNER ELK, NC 28604 (828)898-6277 CLIENT: BLUE RIDGE LABS LOGIN TIME: CITY: LENOIR RECEIVED DATE: 7-Nov-19 STATE: NC ZIP 28645 REPORTED DATE: 25-Nov-19 I D#: (ANALYSIS.<. I, LSID#. I NALYSI,I MQL's I. UNITS I. S HPIONIANALYSIS INT BOD 5 DAY IP 230.0 2.00 MG/ 8-Nov-19 PI BOD 5 DAY CASE 630.0 2.00 MG/L 8-Nov-19 PI BOD 5 DAY SPLIT 440.0 2.00 MG/L , 8-Nov-19 PI REPORTED BY: NC CERTIFIED LAB#544 Iin 0T A I I Pr..Y /_sw„!n ...run--I PAUL ISENHOUR, SUPERVISOR Blue Ridge Labs, Inc. ...... LA P.O. Box 2940 Lenoir, NC 28645 Telephone(828) 728-0149 Fax(828) 728-0131 Chain of Custody All samples require North Carolina certified analysis unless other wise noted. Non State Reporting Report To: Bill To: Case Farms L 15C Fl�S oimf ift _, f / Project Name: N' G PO Number: Ice Present: Y N C-Composite Field Preservatives Lab Check Time& Field Resid G- Grab Temp Field Sulfide Chlor Field Sample ID Sample Date Time Sulfide Present/ Field Dechlorination pH Resid Temp Sampler Analysis Requested Type FIR:MM Check Removed Check Chlor °C Initials°C YN Y N YN Y N P or A LASE S i!/ibi at., go, 606 a.° ,,t,/� �� CAD — f -+ ass I II Rai 5/1'1- ad ,a /7 41 yoe 4,2 Cev S//,i cer eh? gam, Vie 115 Relyinquis dBy: Date: Time: 7 Pate: Ti Oa 441 Upon submission of samples,client agrees that invoices are due at the time work is completed. Open accounts are due 20 days following invoice date. A finance charge of 1.5%per month will be imposed on all pasiue accounts. When relinquishing samples to Blue Ridge Labs(BRL),buyer authorizes BRL to perform only the analysis indicated above and also agrees to pay ctdction and attorney fees if the account becomes delinquent. Blue Ridge Labs reserves the right to deny documentation for any work where payment has not been made,in effect rendering that data unsupported for regulatory purposes. BRL cannot guarantee that any regulatory authority will accept any work submitted;therefore it is the client's responsibility to request on this form appropriate tests. NC DENR Certified Lab#275 SIU INSPECTION FORM Name Of Industry: Case Farms IUP# 1098 Address Of Industry: 121 Rand Street IUP Expiration Date: Morganton,NC 28655 5/31/2020 Industry Representatives: Title Gary Rutherford Wastewater Manager Phil Richardson Maintenance Su.ervisor - E C,E 1 V E D POTW Representatives: Title Tim Arney Pretreatment Coordinator JAN 21 2020 Date Of Inspection: 9/27/19 Time Of Inspection: 0830 am/P DEQ/DWR/NPDES Purpose of Inspection: Annual Other(Describe) POTW to which IU discharges Catawba River NPDES# NC 0026573 Is SIU currently in SNC? No If yes,for what? PART I -INITIAL INTERVIEW Has anything changed since the last inspection or IUP application in the following: COMMENTS Product YES CO • Raw materials used YES IZO Manufacturing processes YES eco Categorical,if applicable YES iri) Production rate YES Rail SA/•)')t Number of employees OUP/NO SO 0 Number of shifts YES 4) 3 a P ea��u C d n/ / SA,v/ q 71/0 Al Comments: PART II -PLANT TOUR- Visit all areas where wastewater is generated or where there are drains to the POTW. Plant Tour Section A-PRODUCTION AND STORAGE AREAS 1. Are there floor drains in the production area? Gp NO Where do they go? Pre 4'r e 4-im e/d i" 2. Are production areas diked,contained,or otherwise constructed in such a way as to prevent harm to the WWTP, especially from spills or slugs? 1400 NO Comments: 3. Are there floor drains in the storage area? MO NO Where do they go? Pre..• re G-M e ni 4. Are storage tanks and areas diked,conta�' jd,or otherwise construtted in such a way as to prevent harm to the , WWTP,especially from spills or slugs? 9/NO Comments: 5. Are process and storage tanks and pipes labeled? M/NO 6. IIow are off-spec raw materials,and products disposed of? VA//c Y Pr 0 74;P_n/S (,As >o„j /A /V C. ' 7. When is the production area cleaned? D A/L Y rrvs/°a ,Le d i y USDA 8. Is the wastewater from cleaning the production area discharged to the POT`W? NO 9. What non-process wastewaters are discharged to POTW? D o/rI e S T i L Comments: Title: SIU Inpsection Form File name: COMP.INSP App 7-D Revision data: August 1,1994 Page 1 SIU INSPECTION FORM PART II -Plant Tour Section B - PRETREATMENT SYSTEM Ask the operator to describe pretreatment system. 1. Does operator seem knowledgable about the system? 0. NO Comments: 2. Are all units operational? <E 'NO L 3. How often does operator/maintenance person check system? C AT;a 0 US 4. Is there an operator for each shift? YES/ /k, a n 5. How and when is sludge disposed of? V y /fir o ei v ' d i SPn�S'a cif c'f 6. Is there a schedule for preventative maintenance? ©/NO • Comments: PART II- Plant Tour Section C - SAMPLING POINT(S) AND FLOW MEASUREMENT (Collect a sample if desired.) // 1. Does an outside lab complete sampling? ft/NO If yes,name of lab. Q�0 Ri d8 P. 2. If industry completes sampling,ask the industry representative to describe sampling procedures. Comments: 3. Is flow meassL9rement equipment operational? lT E3)/NO Comments: -PA w !»C t e r put' in, o(ur i Ncj ?a lu S'TruC�i.s f/ (JP fj r de. 4. Is there a calibrationlog for the flow meter? YES-/ita, Comments: Comments: PART III - EXIT INTERVIEW Review monitoring records and . her SIU records required by IUP. 1. Are files well organized? O /NO Comments: 2. Are sample collection/chain-of-custody forms filled out properly? OW NO Comments: 3. Do results in files agree with reports sent to POTW? 'E /NO Comments: • 4. ,�;h o has authority to shut down pro uction should a spill or slug discharge occur? PI rn i AwAGe, G�eNer9 ( In/N/96, VS00,9 5. How does SIU inform employees of whom to call at POTW in case of spill/slug? 61// .$#t 6 7� If slug/spill plan is already required by POTW,review procedures. / 6. Is SIU implementing slug/spill plan? /NO Comments: Iupd/a f e d /S y/P et p Comments: INSPECTION RESULTS Slug/Spill Control Plan Needed? YES/@ , Comments,Required Or Recommended Actions: /N P/4 C e Signature Of Inspector(s) ..� �� Date: ,/a /I Title: SIU Inpsection Form File name: COMP.INSP App 7-D Revision data: August 1,1994 Page 2 City of Morganton Printed:12/5/2019, 12:17 PM Page 1 of 3 Allocation Table Headworks last approved: 03/30/11 POTW=> Morganton I Allocation Table updated: • 10/23/18 PDES#=> NC0026573 J Permits last modified: 10/01/15 FLOW BOD TSS Ammonia Industry Type Original Modification Date Permit Limits Permit Limits Permit Limits Permit Limits IUP INDUSTRY NAMES Permit/Pipe of Effective Effective Permit Conc. Load Conc. Load Conc. Load Count (please list alphabetidy) number Industry Date Date Expires MGD gal/day mg/I lbs/day mg/I lbs/day mg/I lbs/day I lase Farms 1098/01 hicken Processor 5/31/2000 10/1/2015 5/31/2020 2.0000 2,000,000 500.00 8340.00 400.00 6672.00 2 eiren I 4002/01 �fextile I 4/1/2002 I 08/24/05 I 3/31/2022 1.5000 1,500,000w 500.00 6255.00 300.00 3753.00 Column Totals=> 3.5000 3,500,000 14595.00 10425.00 1 Basis=> NPDES NPDES NPDES NPDES MAHL from HWA(lbs/day)=> NPDES Permitted Flow=> 8.0000 34528 17263.80 6138.24 Uncontrollable Loading(lbs/day)=> 2.9485 6820 6459.92 614.76 Total Allowable for Industry(lbs/day)=> _ 5.0515 27708 10803.88 5523.48 Total Permitted to Industry(lbs/day)_> 3.5000 14595 10425.00 Allowable loading left(lbs/day)_> 1.5515 13113 378.88 #VALUE! Percent Allow.Ind.still available(%)_> 30.7% 47.3% 3.5% Percent MAHL still available(%)=> 19.4% 38.0% 2.2% 5 Percent MAHL(lbs/day)=> 0.4000 1726 863 306.91 Z CD X 0 - 6 n m b m rri City of Morganton HWA.AT.linked,8,99 City of Morganton Printed: 12/5/2019, 12:17 PM Page 2 of 3 Arsenic Cadmium Chromium Copper Cyanide Lead Mercury Molybdenum Nickel Selenium Silver Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day 0.32501 4.0658 0.3250 4.0658 0.2500 3.1275 onitor monitor 4 0658 4.0658 ' 3.1275 1 Inhibition NPDES F. .Inhibition F. F. NPDES Ceiling F. NPDES F. 5.3949 2.3018 11.8245 125.5941 4.7298 8.0297 0.01122 50.9842 1 10.0371 3.6323 12.6940 0.0738 0.0393 2.9779 2.9410 0.1082 0.5115 0.00738 0.0000 0.3098 0.0000 0.2533 5.3212 2.2625 8.8466 122.6531 4.6216 7.5182 0.00384 50.9842 9.7273 3.6323 12.4407 4.0658 4.0658 3.1275 #VALUE! ######## 4.7809 118.5874 ######## ######## #VALUE! #VALUE! 6.5998 #VALIJI;I ######## 54.0% 96.7% 67.8% 40.4% 94.4% 65.8% 0.27 0IISI 0.5912 6.2797 0.2365 0.4015 0.00056 2.5492 , 0.5019 0.1816 0.63 City of Morganton HWA.AT.linked,8,99 City of Morganton Printed: 12/5/2019, 12:17 PM Page 3 of 3 Zinc Aluminum COD Oil&Grease TTO Phenols Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Permit Limits Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load Conc. Load mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day mg/I lbs/day 2000 33360 100 1668.00, 0.4500 5.6295 2000 25020 5.0000 62.5500 5.6295 58380 1668.00 62.5500 Inhibition Standard F. 142.7141 833.3805 150.12 5.5058 20296 2459.0 0.0000 137.2083 #VALUE! 150.12 5.6295 58380.0000 1668.0000 62.5500 131.5788 #VALUE! 87.57 95.9% #VALUE! #VALUE! 58.3% 92.2% #VALUE! #VALUE! 58.3% 7.1357 41.67 8 City of Morganton HWA.AT.linked,8,99