Subject: Permit No.WQ0006058
Halifax Hatchery #9
Wastewater Irrigation System
Halifax County
Staff of the Division of Water Resources (DWR), Water Quality Regional Operations
Section (WQROS), Raleigh Regional Office (RRO) visited the Perdue Halifax Hatchery 49
Wastewater Surface Irrigation System on January 21, 2020. The purpose of the visit was to
conduct a compliance inspection as part of the permit rrenewal process. Tim Mizelle (ORC as of
November 2019) and Ashton Weller (backup ORC) assisted during the inspection. The current
permit which was issued April 28, 2015 and expires March 31, 2020 was reviewed.
The last inspection at this facility was performed May 31, 2018 and the facility was
compliant with permit requirements.
The wastewater is treated in several septic tanks in series. The septic tanks are pumped
approximately every 5 years. The wastewater then flows to the storage lagoon. The berm was
well mowed and there were signs and a locked fence preventing unauthorized access. The
freeboard was about 3.1 feet and the water was nearly clear and odorless. The treated water is
then pumped from a wet well next to the lagoon to spray -field. Both pumps, the chlorine gas
disinfection system and the flow meter were in good order.
The facility has historically averaged about 9000 gpd of its 15745 gpd permit limit,
applies about 75 of the 400 lbs PAN permit limit and irrigates about 15" of the 4 1 " permitted.
During 2019, the daily flow increased to about 13000 gpd as a result of a change in
sanitation practices. The ORC intends to speak vOth the plant manager to advise him that
the flow is nearing permit limits.
�� North C..irr,I n.r fA p,rr rrrrrit .rf F.'rr.irunrr;r:;t,+I Qu r'ity I I)i; i�.iun �rf LF,itrr Rrriuru crs
, �/ � P.il. iyfi ftr r;iun,rl Offir, inl;O $;it rr9t []r ivr R.rlr'41r, Nol tfr C,r dirr,l' 709
The grass in the 5 acre sprayfield was mowed and the pine trees looked to be in good
condition. No ponding or runoff was noted. The pumps were turned on and all sprayheads
appeared to be in good order.
The ORC reported that the chlorine gas system fails frequently despite being constantly
worked on. The chlorine gas also corrodes the pump room and the o-rings in the plumbing,
creating additional maintenance needs. The ORC expressed an interest in modifying the
permit during the permit renewal process to include a hypochlorite disinfection system and
to keep the chlorine gas system as a backup.
The ORC reported that other than the chlorine gas problems, the system is reliable and
runs well.
All records were reviewed and appear to have been submitted on time, correct and
complete. Soil samples were collected in December 2019. The monitoring wells were not
inspected, but are reportedly in good condition. They are sampled yearly by the ORC.
On the day of the inspection the facility appeared to be operating in compliance with
permit conditions. Please see the attached Inspection Report.
If you have any questions regarding this letter, please contact me at (919) 791-4240 or via
e-mail at ray.milosh c'mcdenr.aov.
Sincerely,
Ray Milosh
*_617ronmZal Specialist
Division of Water Resources, Water Quality
Regional Operations Section, Raleigh
Regional Office
Attachment: Compliance Inspection Report
cc: RRO-WQROS Files
DWR Central Files
Permit: W00006058
SOC:
County: Halifax
Region: Raleigh
Contact Person: Wayne Black
Directions to Facility:
Compliance Inspection Report
Effective: 06/24/15 Expiration: 05/31/20 Owner: Perdue Foods LLC
Effective: Expiration: Facility: Halifax Hatchery #9
670 Perdue Dr
System Classifications: SI,
Primary ORC: Timothy N Mizelle
Secondary ORC(s):
On -Site Representative(s).
Related Permits:
Inspection Date: 01121/2020
Primary Inspector: Raymond M Milosh
Secondary Inspector(s)-
Title:
Entry Time: 01 OOPM
Certification: 18575
Reason for Inspection: Routine
Permit Inspection Type: Wastewater Irigation
Facility Status: Compliant Nol Compliant
Question Areas:
Miscellaneous Questians Treatment
Treatment Lagoons End Use -Irrigation
(See attachment summary)
Halifax NC 27839
Phone: 252-348-4326
Phone: 252-348-4291
Exit Time: 02.00PM
Phone: 919-791-4200
Inspection Type: Compliance Evaluation
Record Keeping
Treatment Disinfection
Page 1 of 5
permit. WOOCUB058 Owner -Facility: Perdue Foods LLC
inspection Date: 0112112020 Inspection Type: Compliance Evaluation Reason for Visit: Routine
Inspection Summary:
Staff of the Division of Water Resources (DWR), Water Quality Regional Operations Section (WORDS), Raleigh Regional
Office (RRO) visited the Perdue Halifax Hatchery #9 Wastewater Surface Irrigation System on January 21, 2020. The
purpose of the visit was to conduct a compliance inspection as part of the permit reenewal process. Tim Mizelle (ORC as of
November 2019) and Ashton Weller (backup ORC) assisted during the inspection. The current permit which was issued
April 28, 2015 and expires March 31, 2020 was reviewed.
The last inspection at this facility was performed May 31, 2018 and the facility was compliant with permit requirements.
The wastewater is treated in several septic tanks in series. The septic tanks are pumped approximately every 5 years.
The wastewater then flows to the storage lagoon. The berm was well mowed and there were signs and a locked fence
preventing unauthorized access. The freeboard was about 3.1 feet and the water was nearly clear and odorless. The
treated water is then pumped from a wet well next to the lagoon to sprayfield. Both pumps, the chlorine gas disinfection
system and the flow meter were in good order.
The facility has historically averaged about 9000 gpd of its 15745 gpd permit limit, applies about 75 of the 400 lbs PAN
permit limit and irrigates about 15" of the 41' permitted.
During 2019, the daily flow increased to about 13000 gpd as a result of a change in sanitation practices. The ORC intends
to speak with the plant manager to advise him that the flow is nearing permit limits.
The grass in the 5 acre sprayfield was mowed and the pine trees looked to be in good condition. No ponding or runoff was
noted. The pumps were turned on and all sprayheads appeared to be in good order.
The ORC reported that the chlorine gas system fails frequently despite being constantly worked on. The chlorine gas also
corrodes the pump room and the o-rings in the plumbing, creating additional maintenance needs. The ORC expressed an
interest in modifying the permit during the permit renewal process to include a hypochlorite disinfection system and to keep
the chlorine gas system as a backup.
The ORC reported that other than the chlorine gas problems, the system is reliable and runs well.
All records were reviewed and appear to have been submitted on time, correct and complete. Soil samples were collected in
December 2019. The monitoring wells were not inspected, but are reportedly in good condition. They are sampled yearly by
the ORC.
On the day of the inspection the facility appeared to be operating in compliance with permit conditions. Please see the
attached Inspection Report.
Page 2 of 5
Permit: W00006058 Owner - Facility. Perdue Foods LLC
Inspection Date: 01121/2020 Inspection Type • Compliance Evaluation
Reason for Visit: Routine
iy pg
Yes No NA NE_
Single Family Drip
ri
Reuse (Quality)
Single Family Spray, LR
ri
Recycle/Reuse
Activated Sludge Drip, LR
El
Activated Sludge Spray, HR
Infiltration System
Activated Sludge Spray, LR
rl
Lagoon Spray, LR
■
Treatment
Yes No NA NE
Are Treatment Facilities consistent with those outlined in the current permit?
Do all treatment units appear to be operational? (if no, note below.)
.
Comment:
Treatment Disinfection
Yes No NA NE
Is the system working?
. 13110
Do the fecal coliform results indicate proper disinfection?
Is there adequate detention time (>=30 minutes)?
■
Is the system property maintained?
■
If gas, does the cylinder storage appear safe?
■
Is the fan in the chlorine feed room and storage area operable?
Is the chlorinator accessible?
El D■
If tablets, are tablets present?
■
Are the tablets the proper size and type?
■
Is contact chamber free of sludge, solids, and growth?
.
If UV, are extra UV bulbs available?
0
If UV, is the UV intensity adequate?
■
# Is it a dual feed system?
■ El
Does the Stationary Source have more than 2500 lbs of Chlorine (CAS No. 7782-50-5)?
0 ❑
If yes, then is there a Risk Management Plan on site?
❑ ■ ❑
If yes, then what is the EPA twelve digit ID Number? (1000-_ __)
If yes, then when was the RMP last updated?
Comment:
Record Keeainu
Yes No NA NE
Page 3 of 5
Permit: W00006058 Owner - Facility: Perdue Foods LLC
Inspection Date: 01/2112020 Inspection Type: Comphance Evaluation
Reason for Visit Routine
Is a copy of current permit available?
0 ❑ ❑ ❑
Are monitoring reports present: NDMR?
N ❑ ❑ ❑
NDAR?
0 ❑
Are flow rates less than of permitted flow?
❑ ❑ ❑
Are flow rates less than of permitted flow?
❑ ❑ ❑
Are application rates adhered to?
❑ ❑ ❑
Is GW monitoring being conducted, if required (GW-59s submitted)?
E ❑ ❑ ❑
Are all samples analyzed for all required parameters?
0 ❑ ❑ ❑
Are there any 2L GW quality violations?
❑ ❑ ® ❑
Is GW 59A certification form completed for facility?
N ❑ ❑ ❑
Is effluent sampled for same parameters as GW?
0 ❑ ❑ ❑
Do effluent concentrations exceed GW standards?
❑ ❑ 0 ❑
Are annual sail reports available?
E ❑ ❑ ❑
# Are PAN records required?
0 ❑ ❑ 11
# Did last soil report indicate a need for lime?
❑ ❑ ❑ 0
If so, has it been applied?
❑ ❑ ❑ 0
Are operational logs present?
N ❑ ❑ ❑
Are lab sheets available for review?
■ ❑ ❑ ❑
Do lab sheets support data reported on NDMR?
E ❑ ❑ ❑
Do lab sheets support data reported on GW 59s?
E ❑ ❑ ❑
Are Operational and Maintenance records present?
E ❑ ❑ ❑
Were Operational and Maintenance records complete?
❑ ❑ ❑
Has permittee been free of public complaints in last 12 months?
❑ ❑ ❑
Is a copy of the SOC readily available?
❑ ❑ ❑
No treatment units bypassed since last inspection?
❑ ❑ ❑
Comment:
End Use -Irrigation
Yes No NA NE
Are buffers adequate?
N ❑ ❑
Is the cover crop type specified in permit?
0 ❑ ❑ ❑
Is the crop cover acceptable?
Is the site condition adequate?
0 ❑ ❑
Is the site free of runoff I ponding?
Cl ❑ ❑
Is the acreage specified in the permit being utilized?
❑ ❑ ❑
Is the application equipment present?
S ❑ ❑ ❑
is the application equipment operational?
❑ ❑ ❑
Is the disposal field free of limiting slopes?
❑ ❑ ❑
Page 4 of 5
Permit: W00006058 Owner -Facility: Perdue Foods LLC
Inspection Date: 01/21/2020 Inspection Type: Compliance Evaluation
Is access restricted and/or signs posted during active site use?
Are any supply wells within the CB?
Are any supply wells within 250' of the CB?
How close is the closest water supply well?
Is municipal water available in the area?
# Info only: Does the permit call for monitoring wells?
Are GW monitoring wells located property wl respect to RB and CB?
Are GW monitoring wells properly constructed, including screened interval?
Are monitoring wells damaged?
Comment:
Reason for Visit Routine
■❑❑❑