HomeMy WebLinkAboutSW6191004_C-502_1/22/20201 FOR OFFICIAL USE ONLY 2 3 5 1 6 1 7 1 8 1 9 1 10 4' MAX. G F E FBI C n SPIGOT END ON INLET END SECTIONS HUB END ON OUTLET END SECTIONS E PLAN — BAR OR STEEL FABRIC REINFORCING C B A L ---i ::: SECTION A -A FRONT ELEVATION END SECTION DIMENSIONS DIA A B C D E 15" 6" 2'-3" 1'-9" 4'-0" 2'-6" FLARED END SECTION DETAIL CU101 IC-502 NOT TO SCALE 50' MIN. NCDOT #5 OR #5• WASHED STONE GENERAL NOTES: 1. UNIFORMLY GRADE A SHALLOW DEPRESSION APPROACHING THE INLET. 2. DRIVE 5-FOOT STEEL POSTS 2 FEET INTO THE GROUND SURROUNDING THE INLET. SPACE POSTS EVENLY AROUND THE PERIMETER OF THE INLET, A MAXIMUM OF 4 FEET APART. 3. SURROUND THE POSTS WITH WIRE MESH HARDWARE CLOTH. SECURE THE WIRE MESH TO THE STEEL POSTS AT THE TOP, MIDDLE, AND BOTTOM. PLACING A 2-FOOT FLAP OF THE WIRE MESH UNDER THE GRAVEL FOR ANCHORING IS RECOMMENDED. 4. PLACE CLEAN GRAVEL (NC DOT #5 OR #57 STONE) ON A 2:1 SLOPE WITH A HEIGHT OF 16 INCHES AROUND THE WIRE, AND SMOOTH TO AN EVEN GRADE. 5. ONCE THE CONTRIBUTING DRAINAGE AREA HAS BEEN STABILIZED, REMOVE ACCUMULATED SEDIMENT, AND ESTABLISH FINAL GRADING ELEVATIONS. 6. COMPACT THE AREA PROPERLY AND STABILIZED IT WITH GROUNDCOVER. FILTERED WAT E R NCDOT #5 OR #57 WASHED STONE mono uuum 4n nAi ins "AnnIAiAnr: CLOTH MAINTENANCE: INSPECT INLETS AT LEAST WEEKLY AND AFTER EACH SIGNIFICANT (Y INCH OR GREATER) RAINFALL EVENT. CLEAR THE MESH WIRE OF ANY DEBRIS OR OTHER OBJECTS TO PROVIDE ADEQUATE FLOW FOR SUBSEQUENT RAINS. TAKE CARE NOT TO DAMAGE OR UNDERCUT THE WIRE MESH DURING SEDIMENT REMOVAL. REPLACE STONE AS NEEDED. HARDWARE CLOTH AND GRAVEL INLET PROTECTION CG 101 1 C-502 NOT TO SCALE W O 0 0 OOOOo OOOOo OO 0 °OD O°°OD° O °°po� 0°°°°°°°°O° )0c)0OO O �00 �00 0 NCDOT CLASS A STONE z 73 ° 0 °D 0 N EXISTING NEW CONSTRUCTION °� 90000010O�J0 00 °0 0 ROADWAY 50'MIN. �00 00 0 00000 OOo O °000 00 O O 00 O O 00 6" MIN. a 0 � 0°� 0°� 0° OHO ,0000� O 0 O O PLAN Aoi�o% CONSTRUCTION SPECIFICATIONS FABRIC UNDER STONE ` (TEMPORARY GRAVEL CONSTRUCTION ENTRANCE/EXIT) MAINTENANCE: CROSS SECTION IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSURE THAT 1. CLEAR THE ENTRANCE AND EXIT AREA OF ALL VEGETATION, ROOTS SEDIMENT IS NOT TRACKED ONTO THE EXISTING PAVED AND OTHER OBJECTIONABLE MATERIAL AND PROPERLY GRADE IT. STREET. THE ENTRANCE /EXIT SHALL BE MAINTAINED IN A 2. PLACE THE GRAVEL TO THE SPECIFIC GRADE AND DIMENSIONS CONDITION WHICH WILL PREVENT TRACKING OR FLOW OF SHOWN ON THE PLANS, AND SMOOTH IT. MUD ONTO PUBLIC STREETS OR RIGHTS -OF -WAY. THIS MAY REQUIRE PERIODIC TOP DRESSING WITH NCDOT 3. PROVIDE DRAINAGE TO CARRY WATER TO SEDIMENT TRAP OR CLASS A STONE, AS CONDITIONS DEMAND AND REPAIR OTHER SUITABLE OUTLET. AND/OR CLEANOUT OF ANY STRUCTURES USED TO TRAP SEDIMENT. ALL MATERIALS SPILLED, DROPPED, WASHED, 4. USE GEOTEXTILE FABRICS BECAUSE THEY IMPROVE STABILITY OF OR TRACKED FROM VEHICLES OR SITE ONTO ROADWAYS THE FOUNDATION IN LOCATIONS SUBJECT TO SEEPAGE OR OR INTO STORM DRAINS SHALL BE REMOVED IMMEDIATELY. HIGH WATER TABLE. 5. IF CONSTRUCTION ON THE SITES AREA SUCH THAT THE MUD IS NOT REMOVED BY THE CONSTRUCTION ENTRANCE, TIRES OF THE VEHICLES MUST BE WASHED BEFORE LEAVING THE SITE. TEMPORARY GRAVEL CONSTRUCTION ENTRANCE / EXIT DETAIL CG101C-502 VOT TO SCALE 2" PEA GRAVEL LAYE ELEV.=243.0 FT FILTER FABRIC — OVERFLOW SEE — DETAIL 5 THIS SHEET NOTES: NOT TO SCALE 1. 5 ACRE MAXIMUM DRAINAGE AREA. SLOPE PER PLAN NOT TO EXCEED 3:1 (H:V) ELEV=244.2 18" COURSE OF CLASS A RIPR/ 12" OF NCDOT #5 OR #57 WASHED STONE ELEV.243.5 SWM#1 ELEV.= 243' WATER QUALITY VOLUME OBSERVATION WELL RUNOFF FILTERS THROUGH F�0\� GRASS BUFFER STRIP TRENCH 1.5 FEET DEEP �1.5-2.5 INCH DIAMETER CLEAN STONE CLEAN, WASHED SAND, 6" DEEP (OR FILTER FABRIC EQUIVALENT) RUNOFF EXFILTRATES THROUGH UNDISTURBED SUBSOILS. INFILTRATION TRENCH DETAIL CG 101 I C-502 NOT TO SCALE FILTER CLOTH 1.5' 244.5-- �P PROVIDE 10.0' OF WIDTH AT DEPTH SHOWN IN B-B ELEV.= 244.0' 10.0' SECTION A -A SECTION B-B 5.0' � E a X 244.8 SLOPE PER PLAN NOT TO EXCEED 3:1 (H:V) ELEV.=244.2' FILTER CLOTH SLOPE TO EX. GRADE ELEV.=244.5' 5 OVERFLOW DETAIL CG101 C-502 NOT TO SCALE N r CAR ......I... <i o .. FESS/O .. ti , US Army Corps of Engineers® IIIIII IIIIII X X UJ Z .. 0 X0Xo rn z X z X U ~ 1 -- o~ x�x x x U x Of 0 X< X 0 X J D -ixzX�X x UU x x W 0 U w Q w mQ m pQL co uj c� � z uj 0 (� W QQ W O w = Um 0 Qw D CO _ (� N Z 0 00 �U �co o Q 0 0 w ui M ui W Z J zo � N 0; U< � U N p z w Q U LL z c00o 0 w=�,�w z U) = o ° O J w 0 z z0 00Q---j O a� (D z � oho cd J C7 = c�z M Q � 0 � J_ U z� J 0 0z U Q W J H W 0o w z� p 0� J U) m� of � M LO M z 4 = SHEET ID NE ,I S C-502 Ili \ 0�96/2020 FOR OFFICIAL USE ONLY ISSUED FOR CONSTRUCTION