HomeMy WebLinkAboutWS0801041_Report_20200121December 30, 2019 NCDEQ Division of Water Resources Attn.: Dr. Morella Sanchez -King, PhD, PE 127 Cardinal Drive Extension Wilmington, NC 28405-3845 Re.: INVISTA-Sarl Newly Installed Water Supply Well Information morella.sanchez-king(a-)ncdenr.gov Dr. Sanchez -King, The following information is provided for review: Table 1 24 Hour Pumping Test Results (OA-3) Table 2 24 Hour Pumping Test Results (OB-3) Figure 1 Newly Constructed Water Well Locations Geothermal, Environmental, & Well Drilling Appendix A NC High Capacity Well Permit Appendix B Boring Logs, Well Construction Diagrams, and NC Well Construction Records If you have questions or require further information, do not hesitate to call. Sincerely, qJoeph. Zuncich Project Manager, CWD, Environmental Geologist cc. Ms. Elizabeth Meyer, INVISTA-Sari, w/enclosures Applied Rcoource Management, F C. P. O. Box 882, 257 Transfer Station Koad, Hampstead, NC 25443 910.270.2919 Fax 910.270.29&8 TABLE 1 11/20-21/2019 24 HOUR PUMPING TEST INVISTA S.A.R.L. WELL OA-3 Conducted with guidance from the May 31, 2007 Performance and Analysis of Aquifer Slug Tests and Pumping Tests Policy 'rime OA-3 ; F'SI Pumping Rafe ' (9pm) Discharge Gallons),. AATW-# DTW (ft) .. /1ATW2 DTtN (fE) AA DTW,{ftj' 0 static= 9.80 0 0 static=11.74 static=10.27 static=9.89 210 10(sees) 11.91 160+ 210 - 20 12.62 160+ 210 - - 30 13.90 160+ 210 - - - 40 14.12 160+ 210 - 50 14.21 160+ 210 - 60 (1 min) 14.32 160+ 210 - 80(secs) 14.39 160+ 210 - 420 100 (secs) 14.43 160+ 210 - - 120 (secs) 14.45 160+ 210 - - 140(secs) 15.10 155 215 - - - 645 160(sees) 15.29 150 220 - - - 180(sces) 15.40 145 225 - - - 200(secs) 15.49 140 230 - - - 890 220(secs) 16.01 135 245 - - - 240(secs) 16.30 135 245 - - - 260(secs) 16.70 135 245 - - - 1,140 _ 280(secs) 17.28 130 250 - - - 300 (5 mins) 18.35 130 250 11.98 10.27 9.93 330 (secs) 19.06 125 255 1,400 12.03 10.27 9.95 360 (secs) 19.70 120 260 12.06 10.27 9.97 390 (secs) 21.01 120 260 1,665 12.08 10.27 9.98 420 (secs) 21.00 115 265 12.11 10.27 9.99 450 (secs) 21.70 115 265 1935 12.14 10.27 10.00 480 (secs) 21.73 110 270 12.16 10.27 10.01 510 (secs) 22.50 110 270 2,205 12.17 10.27 10.02 540 (secs) 22.75 110 270 12.19 10.27 10.04 570 (secs) 23.02 100 275 2,480 12.21 10.27 10,07 600 (10 mins) 23.35 100 275 12.22 10.27 10.10 '' T1ma flA-'St a Fum1n� Ra#s ,' �. Dinar i ,-` AAfW 1l DTfN"(#t}, 3 aDTVY�itf � AA , ,' M, T3TW (it}: 660 secs 23.70 94 280 3,040 12.27 10.27 10.12 720 sec 23.73 92 280 12.32 10.27 10.13 780 sec 23.90 89 285 3,610 12.36 10.27 10.15 840 sec 24.00 87 285 12.41 10.27 10.16 900 (15 min) 24.13 86 295 4,495 12.46 10.27 10.18 960 sec 24.15 85 295 12.51 10.27 10.20 1020 sec 24.15 84 295 12.56 10.27 10.21 1080 sec 24.30 83 300 5,395 12.61 10.27 10.23 1140 sec 24.35 82 300 12.66 10.27 10.25 1200 (20 mins) 24.40 82 300 12.77 10.27 10.26 1500 24.52 80 305 17,595 12.79 10.27 10.28 1800 24.65 78 305 12.84 10.27 10.32 2100 24.69 78 305 12.87 10.27 10.35 2400 24.78 78 305 12.90 10.27 10.37 2700 24.79 78 305 12.92 10.27 10.39 3000 24.82 78 305 12.93 10.27 10.40 3600 (1 hour) 24.87 78 305 12.95 10.27 10.42 75 (Mins) 24.90 78 305 35,895 12.98 10.27 10.43 90 min 24.93 78 305 13.00 10.27 10.44 105 min 25.00 78 305 13.11 10.27 10.44 120 min (2hr) 25.03 78 305 13.15 10.27 10.43 135 min 25.07 78 305 54,195 13.18 10.27 10.46 150 min 25.10 78 305 13.20 10.27 10.49 165 min 25.10 78 305 13.23 10.27 10.50 180 min (3hr) 25.11 78 305 13.24 10.27 10.50 195 min 25.11 78 305 72,495 13.27 10.27 10.51 210 min 25.11 78 305 13.29 10.27 10.51 225 min 25.11 79 305 13.32 10.27 10.53 240 min (4hr) 25.12 79 305 13.31 10.27 10.52 255 min 25.14 79 305 90,795 13.33 10.27 10.52 270 min 25.18 79 305 13.34 10.27 10.52 285 min 25.20 79 305 13.37 10.27 10.53 300 (5 hours) 25.20 79 305 13.39 10.27 10.54 315 min 25.21 79 305 99,945 13.39 10.27 10.53 330 min 25.22 79 305 13.40 10.27 10.53 c� '55,PSJ } DiiN {ff) N Pi roplt� Rate 17, nKM Dischar rGal�o»a AAi 11 DTW {ftj AA't1 f , tTW {ft} ' AA DTG1((ft} 345 min 25.24 79 305 109,095 13.42 10.27 10.54 360 min (6hr) 25.27 79 305 13.43 10.27 10.55 375 min 25.28 79 305 127,395 13.44 10.27 10.55 390 min 25.29 79 305 13.44 10.27 10.56 405 min 25.30 79 305 13.45 10.27 10.56 420 min (7hr) 25.30 79 305 13.46 10.26 10.56 435 min 25.31 79 305 182,295 13.46 10.26 10.57 450 min 25.32 79 305 13.47 10.26 10.57 465 min 25.32 79 305 13.48 10.26 10.58 480 min 25.33 79 305 13.50 10.26 10.58 495 min 25.33 79 305 13.52 10.26 10.58 510 min 25.34 79 305 13.53 10.26 10.59 525 min 25.35 79 305 13.54 10.26 10.59 540 min 25.36 79 305 13.54 10.26 10.59 555 min 25.36 79 305 13.54 10.25 10.58 570 min 25.37 79 305 13.54 10.23 10.58 585 min 25.37 79 305 13.55 10.22 10.58 600 (10 hours) 25.38 79 305 13.55 10.21 10.57 615 min 25.38 79 305 237,195 13.55 10.21 10.57 630 min 25.39 79 305 13.55 10.21 10.58 645 min 25.39 79 305 13.56 10.20 10.57 660 min 25.40 79 305 13.56 10.20 10.57 675 min 25.40 79 305 13.56 10.19 10.57 690 min 25.41 79 305 13.56 10.19 10.57 705 min 25.41 79 305 13.56 10.19 10.58 720 min 25.41 79 305 1157 10.18 10.58 735 min 25.42 79 305 13.57 10.17 10.57 750 min 25.41 79 305 13.56 10.17 10.57 765 min 25.42 79 305 13.57 10.17 10.57 780 min 25.42 79 305 13.58 10.16 10.57 795 min 25.42 79 305 255,495 13.58 10.16 10.57 810 min 25.43 79 305 13.59 10.15 10.57 825 min 25.43 79 305 13.58 10.15 10.57 840 min 25.43 79 305 13.59 10.15 10.56 855 min 25.44 79 305 260,070 13.59 10.14 10.57 ?J# 3 PS PtlrYlplttg i s#8 L± s 18Tg$ AA'�WI 1 2 gia Ali 870 min 25.44 79 305 273,795 13.60 10.14 10.56 885 min 25.45 79 305 13.60 10.14 10.57 900 (15 hours) 25.46 79 305 13.60 10.13 10.56 915 min 25.46 79 305 365,295 13.61 10.13 10.56 930 min 25.46 79 305 13.62 10.13 10.55 945 min 25.46 79 305 13.62 10.13 10.56 960 min 25.47 79 305 13.61 10.13 10.55 975 min 25.47 79 305 13.62 10.12 10.55 990 min 25.48 79 305 13.62 10.12 10.55 1005 min 25.48 79 305 13.62 10.12 10.55 1020 min 25.49 79 305 13.63 10.12 10.55 1035 min 25.49 79 305 13.63 10.12 10.55 1050 min 25.50 79 305 13.64 10.11 10.55 1065 min 25M 79 305 13.64 10.11 10.55 1080 min 25.50 79 305 13.63 10.11 10.55 1095 min 25.51 79 305 13.64 10.11 10.55 1110 min 25.52 79 305 13.64 10.11 10.55 1125 min 25.52 79 305 13.65 10.11 10.55 1140 min 25.53 79 305 13.65 10.10 10.55 1155 min 25.51 79 305 13.64 10.10 10.53 1170 min 25.51 79 305 13.63 10.10 10.51 1185 min 25.51 79 305 13.64 10.10 10.51 1200 (20 hours) 25.51 79 305 13.65 10.10 10.51 1215 min 25Z2 79 305 383,595 13.66 10.10 10.52 1230 min 25.53 79 305 13.67 10.10 10.53 1245 min 25.55 79 305 13.68 10.10 10.54 1260 min 25.56 79 305 13.69 10.10 10.55 1275 min 25.56 79 305 401,895 13.69 10.09 10.55 1290 min 25.56 79 305 13.69 10.08 10.55 1305 min 25.56 79 305 13.69 10.08 10.55 1320 min 25.56 79 305 13.70 10.08 10.55 1335 min 25.56 79 305 420,195 1170 10.08 10.55 1350 min 25.56 79 305 13.70 10.08 10.55 1365 min 25.56 79 305 13.70 10.08 10.55 1380 min 25.56 79 305 1170 10.08 10.55 agp iP31 s PL1kItp I3 Rat& Disarg� kA� T► 1AiVY�1 MOO* 1395 min 25.56 79 305 438,495 13.70 10.08 10.55 1410 min 25.56 79 305 13.70 10.08 10.55 1425 min 25.56 79 305 13.70 10.08 10.55 1440 (24 hours) 25.56 79 305 13.70 10.08 10.55 Drawdown 15.76' Gals Total 438,495 1.96' +0.19' 0.66' A ' Discharge Pump test was conducted at a discharge rate of 305 gallons per minute for a period of 24 hours. Note: Well AATW-2 positive water level increase believed to be lunarly/tidal influenced. Well Depth: 68' Casing Depth: 0-38' Screen Depth: 38-68' Pump Intake: 35.5' Maximum Drawdown Level: 25.56' Anticipated Working Yield at 10' above pump intake: 305 gpm TABLE 2 11/20-21/2019 24 HOUR PUMPING TEST INVISTA S.A.R.L. WELL OB-3 Conducted with guidance from the May 31, 2007 Performance and Analysis of Aquifer Slug Tests and Pumping Tests Policy Time O&3 PSt� Pumping Rats Dsg�arge STYV 3 0 static= 8.73 0 0 200 static=9.23 10 (secs) 12.90 132 200 - 20 13.20 132 200 - 30 13.47 132 200 - 40 13.69 132 200 - 50 13.85 132 200 - 60 (1 min) 14.00 132 200 - 80 (secs) 15.55 131 205 405 - 100 (secs) 17.10 131 205 - 120 (secs) 18.20 131 205 - 140 (secs) 18.70 131 205 615 160 (secs) 19.10 131 205 - 180 (sces) 21.07 130 210 - 200 (secs) 22.40 130 210 830 - 220 (secs) 22.85 130 210 - 240 (secs) 23.10 129 215 - 260 (secs) 23.16 129 215 1,045 - 280 (secs) 23.20 129 215 - 300 (5 mins) 23.51 129 215 9.64 330 (secs) 23.75 128 220 1,265 9.67 360 (secs) 23.91 128 220 9.69 390 (secs) 23.97 128 220 1,485 9.71 420 (secs) 24.03 128 220 9.73 450 (secs) 24.10 128 220 1,705 9.76 480 (secs) 24.14 128 220 9.78 510 (secs) 24.16 128 220 1,925 9.80 540 (secs) 24.17 128 220 9.82 570 (secs) 24.19 128 220 2,145 9.85 600 (10 mins) 24.20 128 220 9.87 ime OBE PSl �� Pum}a)nRae Discharge B3W , 660 secs 24.85 127 250 2,645 9.89 720 sec 24.89 127 250 9.90 780 sec 25.16 127 250 3,165 9.92 840 sec 25.35 126 270 9.93 900 (15 min) 25.35 126 270 3,975 9.93 960 sec 25.40 126 270 9.94 1020 sec 25.48 126 270 9.95 1080 sec 25.47 126 270 4,795 9.96 1140 sec 25.49 126 270 9.97 1200(20 mins) 25.49 125 280 9.98 1500 25.50 125 280 15,995 10.01 1800 25.51 125 280 10.05 2100 25.50 125 280 10.05 2400 25.51 125 280 10.06 2700 25.50 125 280 10.06 3000 25.51 125 280 10.09 3600 (1 hour) 25.53 125 280 10.09 75 (Mins) 25.52 125 280 32,795 10.12 90 min 25.51 125 280 10.16 105 min 25,50 125 280 10.17 120 min (2hr) 25.50 125 280 10.19 135 min 25.50 125 280 49,595 10.20 150 min 25.51 125 280 10.21 165 min 25.53 125 280 10.23 180 min(3hr) 25.52 125 280 10.25 195 min 25.52 125 280 66,395 10.27 210 min 25.58 125 280 10.28 225 min 25.58 125 280 10.28 240 min (4hr) 25.60 125 280 10.29 255 min 25.63 125 280 83,195 10.30 270 min 25.64 125 280 10.33 285 min 25.65 125 280 10.34 300 (5 hours) 25.60 125 280 10.34 315 min 25.61 125 280 91,595 10.36 330 min 25.62 125 280 10.36 '`�^ '`lrr .,:.. �A^n7 d DiVftfti l ,' a ',s=i�ili� x9p)IRB 71C1L }J,Ii(la e' Rf{bons} = DTYI± jit 345 min 25.69 126 280 99,995 10.39 360 min(6hr) 25.75 126 280 10.42 375 min 25.76 127 280 116,795 10.43 390 min 25.77 127 280 10.44 405 min 25.78 127 280 10.44 420 min (7hr) 25.78 127 280 10.45 435 min 25.79 127 280 167,195 10.45 450 min 25.79 127 280 10.46 465 min 25.80 127 280 10.46 480 min 25.80 127 280 10.46 495 min 25.81 127 280 10.47 510 min 25.81 127 280 10.47 525 min 25.82 127 280 10.48 540 min 25.82 127 280 10.48 555 min 25.83 127 280 10.49 570 min 25.83 127 280 10.50 585 min 25.83 127 280 10.50 600 (10 hours) 25.84 127 280 10.51 615 min 25.84 127 280 217,595 10.51 630 min 25.84 127 280 10.51 645 min 25.85 127 280 10.51 660 min 25.85 127 280 10.51 675 min 25.85 127 280 10.51 690 min 25.85 127 280 10.52 705 min 25.86 127 280 10.52 720 min 25.86 127 280 10.52 735 min 25.86 127 280 10.52 750 min 25.87 127 280 10.52 765 min 25.87 127 280 10.52 780 min 25.88 127 280 10.53 795 min 25.88 127 280 234,395 10.53 810 min 25.89 127 280 10.53 825 min 25.89 127 280 10.53 840 min 25.89 127 280 10.53 855 min 25.89 127 280 238,595 10.54 Time f +CyB-3 ni PSi $ Pumping-, e 1?ischarge {Gai�ons)< B � D7W i 870 min 25.90 127 280 251,195 10.54 885 min 25.91 127 280 10.54 900 (15 hours) 25.92 127 280 10.55 915 min 25.94 127 280 335,195 10.55 930 min 25.95 127 280 10.55 945 min 25.96 127 280 10.56 960 min 25.97 127 280 10.55 975 min 25.97 127 280 10.56 990 min 25.98 127 280 10.56 1005 min 25.99 127 280 10.56 1020 min 25.00 127 280 10.57 1035 min 25.01 127 280 10.57 1050 min 25.01 127 280 10.59 1065 min 25.02 127 280 10.58 1080 min 25.03 127 280 10.58 1095 min 25.04 127 280 10.59 1110 min 25.05 127 280 10.59 1125 min 25.06 127 280 10.59 1140 min 25.07 127 280 10.60 1155 min 25.08 127 280 10.61 1170 min 25.09 127 280 10.61 1185 min 26.09 127 280 10.62 1200 (20 hours) 26.07 127 280 10.60 1215 min 26.05 127 280 351,995 10.58 1230 min 26.07 127 280 10.58 1245 min 26.10 127 280 10.59 1260 min 26.11 127 280 10.61 1275 min 26.10 127 280 368,795 10.62 1290 min 26.11 127 280 10.62 1305 min 26.13 127 280 10.63 1320 min 26.13 127 280 10.63 1335 min 26.13 127 280 385,595 10.63 1350 min 26.13 127 280 10.63 1365 min 26.13 127 280 10.63 1380 min 26.13 127 280 10.63 Nk T1 g13-'S1 Pmpn� Rafe DischargeTW DiYV:i r 1395 min 26.13 127 280 402,395 10.63 1410 min 26.13 127 280 10.63 1425 min 26.13 127 280 10.63 1440 (24 hours) 26.13 127 280 10.63 Drawdown A' 17.40' Gals Total 402,395 1.40' Discharge Pump test was conducted at a discharge rate of 280 gallons per minute for a period of 24 hours. Well Depth: 68' Casing Depth: 0-38' Screen Depth: 38-68' Pump Intake: 35.5' Maximum Drawdown Level: 26.13' Anticipated Working Yield at 10' above pump intake: 280 gpm Ilk DocuSign Envelope ID: 40DD3017-3A63-42E5-8C26-11981509F6C3 PERMIT NO. WS0801041 NORTH CAROLINA ENVIRON?l1ENTAL MANAGEMENT COMMISSION DEPARTMENT OF ENTN71RONINIENTAL QUALITY RALEIGH, NORTH CAROLINA PERMIT FOR THE CONSTRUCTION OF A «'ELL OR «TELL SYSTEM In accordance with the provisions of Article 7, Chapter 87, North Carolina General Statutes, and other applicable Laws, Rules and Regulations PERMISSION IS HEREBY GRANTED TO INVISTA-Sarl FOR THE CONSTRUCTION OF two (2) large capacity water supply wells in accordance with the application received on July 8, 2019 in conformity with specifications and supporting data, all of which are filed with the Department of Environmental Quality and are considered part of the Permit. The wells will be located at 4600 H,Ary 421 N. (PIN# R02400-001 -001 -000) Wilmington, New Hanover County. This Permit is for well construction only and does not waive any provisions or requirements of the Water Use Act of 1967, or any other applicable laws and regulations. Well construction shall be in compliance with the North Carolina Well Construction Regulations and Standards. This Pen -nit will be effective from the date of its issuance until July 25, 2020, and shall be subject to other specified conditions, limitations, or exceptions as follows: 1. The well(s) shall be constructed in accordance with 15A NCAC 02C .0100. 2. The well(s) shall be constructed and located as shown on the attachments submitted as part of the permit application. 3. A well construction record and copies of well logs, if generated, shall be submitted to the Division. 4. A 24-hour yield test shall be conducted for each well in accordance with 15 NCAC 2C .0110(b) and submitted within 30 days of completion. 5. Well construction records (form GW-1) for the well must be supplied to the Division of Water Resources - Information Processing Unit within 30 days of well completion. 6. Issuance of this Permit does not obligate reimbursement from State trust funds, if the well is being installed as part of an investigation for contamination from an underground storage tank or dry cleaner incident. 7. Issuance of this Permit does not supersede any other agreement, permit, or requirement issued by another agency. 8. The well shall have a Well Contractor Identification Plate in accordance with 15A NCAC 02C.0108 (o). 9. When a well is discontinued or abandoned, it shall be abandoned in accordance with 15A NCAC 02C.0113 and a well abandonment record (form GW-30) shall be submitted to the Division of Water Resources' Infonnation Processing Unit within 30 days of well abandonment. If any requirements or limitations of this Permit are unacceptable, you have the right to an adjudicatory hearing upon written request within 30 days. The request roust be in the form of a written petition conforming to Chapter 150B of the North Carolina General Statutes and filed with the Office of Administrative Hearings, 6714 Mail Service Center, Raleigh, North Carolina 27699-6714. Unless such demand is made, this Permit is final and binding. B,rL?t=LL IL DocuSign Envelope ID: 40DD3017-3A63-42E5-8C26-11981509F6C3 PERINUT NO. WS0801 041 Pennit issued this 25"' day of July 2019 NORTH CAROLINA ENVIRONMENTAL MANAGEMENT COMMISSION EDocuSigned by: j,6 " s- 7DC434.. Morella Sanchez King, PhD, PE, Regional Supervisor Division of Water Resources By Authority of the Emironmental Management Commission cc: ARM (via email) DWR files (Lasei-fiche upload) C:1 i — i:" C PD!' (,:", '11p] Inp"11, 1,11-4 * - 4_ 13''Dl Ff-, 'J"% a s BORING LOG INVISTA S.A.R.L. 4600 HIGHWAY 421 NORTH WILMINGTON, NORTH CAROLINA OA-3 Drilled by: Applied Resource Management Logged by: J. Zuncich Date: 8/20/19 0 - 10 I Light brown to tan, fine to medium grained sands with some I Low I MR coarse sand mixtures with root matter. 10 - 20 1 Tan brown, fine to medium grained sands with minor coarse I Moderate I MR mixtures, organics, wood fragments. to High 20 - 30 Tan brown, fine to medium grained sands with minor coarse High MR mixtures, organics, wood fragments. Coarsening at depth 28'. Coarse with minor gravelly sands. 30 - 40 I Light brown coarse to gravelly sand mixtures with minor wood I High I MR fragments. 40 - 50 1 Brownish orange, coarse sands with come gravel mixture. I High I MR 50 - 60 Brownish orange, coarse sands with come gravel mixture High MR changing to medium gray coarse to gravelly sand mixtures. Clay tense encountered at approximately 54'. 60 - 68 Brownish orange, coarse sands with come gravel mixture High MR changing to medium gray coarse to gravelly sand mixtures. Changing to silty dark gray clay at 68'. MR - Mud Rotary BORING LOG INVISTA S.A.R.L. 4600 HIGHWAY 421 NORTH WILMINGTON, NORTH CAROLINA O B-3 Drilled by: Applied Resource Management Logged by: J. Zuncich Date: 8/13/19 DEPTH (FT) DESCRIPTION' WATER CONTENT BLOW COUNT 0 - 10 Tan to beige, fine to medium graveled sand mixtures with minor wood fragments, organics. Low MR 10 - 20 Light grayish brown medium sands with minor root fragments. Moderate to High MR 20 - 30 Tan brown, fine to coarse grained sand mixtures coarsening at depth. High MR 30 - 40 Tan brown, fine to coarse grained sand mixtures coarsening to gravelly sands at approximately 34' to 35'. Some root fragments observed. High MR 40 - 50 Brown orange to gray coarse to gravelly sand mixtures. High MR 50 - 60 Light to medium gray gravely sands with clay lense at 52'. High MR 60 - 70 Medium gray coarse to gravely sands to 68', changing to dark gray clay. High MR MR - Mud Rotary 1 " X 40' PVC VVell Vent .. 1.5' X 8" Riser With Applied Reeouroe Management, f'C. Hampstead, NC28443 :el 60' TITLE: OA_3 FIGURE: Well Construction Diagram JOB: SCALE: DATE: DRAWN BY: 10038 NTS 8/20/2019 JLZ 1 X 40' PVC Well Vent 1 .5' X 8" Riser With :el 60' T! T LE: a g _3 FIGURE: App/iedRe5ouroe Well Construction Diagram Management, f'C. JOB: SCALE: DATE: DRF,V\,N BY: Ham"cz3 10038 NTS 8/20/2019 JLZ WELL CONSTRUCTION RECORD (GW-1) 1. Well Contractor Information: Donald Cummings Well Contractor Name 2412-A NC Well Contractor Certification Number Applied Resource Management, P.C. Company Name 2. Well Construction Permit #: �/"A List all applicable irell construction pennits (i.e. t:IC C'otmty, State, l hriance. etc.) 3. Well Use (check well use): Water Supply Well: Agricultural Municipal/Public Geothermal (Heating/Cooling Supply) EJ Residential Water Supply (single) x Industrial/Commercial DResidential Water Supply (shared) Irrigation Non -Water Supply Well: Monitoring EIRecovery Injection ''ell: Aquifer Recharge Groundwater Remediation Aquifer Storage and Recovery Salinity Barrier Aquifer Test [3Stormwater Drainage Experimental Technology Subsidence Control Geothermal (Closed Loop) 13Tracer Geothermal (Heating/Cooling Return) M Other (explain under #21 Remarks) 4. Date Well(s) Completed: 8/20/19 Well ID# OA-3 5a. Well Location: Invista S.a.r.l N/A Facility/Owner Name Facility IDh (if applicable ) 4766 N US Hwy 421, Wilmington, NC 28401 Physical Address, City. and Zip New Hanover R02400-001 -001 -000 County Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one lat/long is sufficient) 34 17 55.52 N 7758 19.69 W 6. Is(are) the tvell(s)OPermanent or 0,Temporary 7. Is this a repair to an existing well: rlYes or XJNo If this is a repair, fill out kmomn well construction in formation and explain the nature of the repair under -21 remarks section or on the back of this form. 8. For Geoprobe/DPT or Closed -Loop Geothermal Wells having the same construction, only I GW-I is needed. Indicate TOTAL NUMBER of wells drilled: 1 9. Total well depth below land surface: 68 For multiple wells list all depths if different (example- _ `ai200' and 2 ca 100') 10. Static water level below top of casing: 1 0.5 (ft.) If hater level is above casing, use "- " 11. Borehole diameter: 12 1 /4 (in.) 12. Yell construction method: Mud Rotary (i.e. auger, rotary, cable, direct push. etc.) 14. WATER ZONES FROM TO I DESCRIPTION ft. ft. ft. It. 15.OUTER CASING for multi -cased wells OR LINER if a licable FROM TO DIAMETER THIC[tNESS MATERIAL fL ft. in. 16. INNER CASING OR TUBING(geothermal closed -loon) FROM TO DIAMETER THICKNESS J MATERIAL 0 ft. 38 ft. 8 in' SCH80 PVC ft. ft. in. 17.SCREEN FROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL 38 ft. 68 ft. 8 in- .030 SCH40 Stainless ft. ft. in. 18. GROUT " FROM TO MATERIAL EMPLACEMENT METHOD & AMOUNT 0 ft. 34 ft• Bentonite Poured ft. ft. ft. ft. 19. SAND/GRAVEL PACK if a licable FROM TO MATERIAL I EMPLACEMENT METHOD 34 It- 68 ft- Coarse Poured ft. ft. 20. DRILLING LOG (attach additional sheets if necessary FROM TO I DESCRIPTION (color, hardness. soillrock type, rain size, etc.) ft. ft. ft. ft. See Attached ft. ft. ft. ft. ft ft. ft. ft. ft. ft. 21. REMARKS 22. Ce ification: w� 8/20/19 Signature of Certified Well Contractor Date By signing this form, I hereby verb, that the well(s) was (mere) constnteted in accordance with 15A NCAC 02C .0100 or 15A NCAC 02C .0200 li'ell Construction Standards and that a cop}, of this record has been provided to the well owner. 23. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well construction details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 24a. For All Wells: Submit this form within 30 days of completion of well construction to the following: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 24b. For Iniection 3*8'ells: In addition to sending the form to the address in 24a above, also submit one copy of this form within 30 days of completion of well construction to the following: Division of Water Resources, Underground Injection Control Program, FOR WATER SUPPLY WELLS ONLY: 1636 Mail Service Center, Raleigh, NC 27699-1636 13a. Yield (gpm) 300-325 Method oftest: Airlift 24c. For Water Sunnh & Iniection Wells: In addition to sending the form to o the address(es) above, also submit one copy of this form Nvithin 30 days of 13b. Disinfection type: HTH Amount: 3 /o U� 10g completion of well construction to the county health department of the county where constructed. Form GW-I North Carolina Department of Environmental Quality - Division of Water Resources Revised 2-22-2016 WELL CONSTRUCTION RECORD (GW-1) 1. Well Contractor Information: Donald Cummings Well Contractor Name 2412-A NC Well Contractor Certification Number Applied Resource Management, P.C. Company Name N/A2. Well Construction Permit #: List all applicable well eonstmctio» permits (i.e. I11C. Counht State, 1'ariance, etc.) 3. Well Use (check well use): Water Supply Well: (Heating/Cooling Supply) ommercial Non -Water Supply Well: Aquifer Recharge Aquifer Storage and Recovery Aquifer Test Experimental Technology Geothermal (Closed Loop) 4, Date Well(s) Completed: 8/13/19 5a. Well Location: Invista S.a.r.l Municipal/Public Residential Water Supply (single) Residential Water Supply (shared) rlGroundwater Remediation Salinity Barrier rJStorm,,vater Drainage Subsidence Control Tracer under 921 Remarks Well ID# O B-3 N/A Facility/Owner Name Facility IDk (if applicable) 4766 N US Hwy 421, Wilmington, NC 28401 Physical Address, City, and Zip New Hanover County R02400-001 -001 -000 Parcel Identification No. (PIN) 5b. Latitude and longitude in degrees/minutes/seconds or decimal degrees: (if well field, one latAong is sufficient) 34 18 04.92 N, 77 58 28.60 6. Is(are) the well(s)Permanent or OTemporary W 7. Is this a repair to an existing well: nYes or xINo If this is a repair, fill out known irell construction i 1formation and explain the nature of the repair under -21 remarks section or on the back of this.form. S. For Geoprobe/DPT or Closed -Loop Geothermal Wells having the same construction, only 1 GW-I is needed. Indicate TOTAL NUMBER of wells drilled:1 9. Total well depth below land surface: 68 For multiple wells list all depths tf different (example- 3 a100' and 2 t@r 100') 10. Static water level below top of casing: 8 If hater level is above caring, use "- " 11. Borehole diameter: 12 1 A (in.) 12. Well construction method: Mud Rotary (i.e. auger, rotary, cable, direct push, etc.) (ft.) 14. WATER ZONES FROM TO DESCRIPTION ft. ft. ft. ft. 15. OUTER CASING (for multi -cased wells)OR LINER if a licable FROM TO DLAMETER THICKNESS MATERIAL ft I in. 16. INNER CASING OR TUBING (geothermal closed-loo FROM TO DIAMETER THICKNESS MATERIAL +1.5 ft. 38 ft. 8 in. SCH80 PVC ft. ft. in. 17. SCREEN FROM TO DIAMETER SLOT SIZE THICKNESS MATERIAL 38 ft- 68 ft' 8 in- .030 SCH40 Stainless ft. ft. in. 18. GROUT FROM TO MATERIAL EMPLACEMENT METHOD & AMOUNT 0 ft. 34 ft. Bentonite Poured ft. ft. ft. ft. 19. SAND/GRAVEL PACK if applicable) FROM TO MATERIAL EMPLACEMENT METHOD 34 ft- 68 ft. Coarse Poured ft. ft. 20. DRILLING LOG attach additional sheets if necessary) FROM TO DESCRIPTION (color, hardness, soillrock 0,pe, grain size, etc. ft. ft. ft. ft. See Attached ft. ft. ft. ft. ft. ft. ft. ft. ft. ft. 21. REMARKS 22. Certification: . Ll"v 8/20/19 Signature of Certified Well Contractor Date 13v signing this form, I hereby certify that the wel(s) was (were) constructed in accordance with LM NC9C 02c .0100 or 15A NCAC 02C.0200 Well Construction Standards and that a copy of this record has been provided to the well owner. 23. Site diagram or additional well details: You may use the back of this page to provide additional well site details or well construction details. You may also attach additional pages if necessary. SUBMITTAL INSTRUCTIONS 24a. For All Wells: Submit this form within 30 days of completion of well construction to the followina: Division of Water Resources, Information Processing Unit, 1617 Mail Service Center, Raleigh, NC 27699-1617 24b. For Iniection Wells: In addition to sending the form to the address in 24a above, also submit one copy of this form within 30 days of completion of well construction to the following: Division of Water Resources, Underground Injection Control Program, FOR WATER SUPPLY y17ELLS ONLY: 1636 Mail Service Center, Raleigh, NC 27699-1636 13a. Yield (gpm) 300-325 Method of test: Airlift 24c. For Water Supply & Iniection Wells: In addition to sending the form to o the address(es) above, also submit one copy of this form within 30 days of 13b. Disinfection type: HTH Amount: 3 /o @ 10g completion of well construction to the county health department of the county where constructed. Form GW-I North Carolina Department ofEnvironmental Quality - Division of Water Resources Revised 2-22-2016