Loading...
HomeMy WebLinkAboutSW6200101_PN 69552 CIVIL AFFAIRS TEMF - SPECIFICATIONS JAN2020_1/20/2020SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% PROJECT TABLE OF CONTENTS DIVISION 00 - PROCUREMENT AND CONTRACTING REQUIREMENTS AWARD LETTER ACO LETTER COR APPOINTMENT AMENDMENT 0001 AMENDMENT 0002 AMENDMENT 0003 AMENDMENT 0004 STANDARD FORM 1442 00 00 00 PROCUREMENT AND CONTRACTING REQUIREMENTS 00 10 00 SOLICITATION 00 70 00 CONDITIONS OF THE CONTRACT 00 73 00 SUPPLEMENTARY CONDITIONS DIVISION 01 - GENERAL REQUIREMENTS 01 10 00.10 38 SUPPLEMENTARY SPECIAL CONTRACT REQUIREMENTS 01 11 00 SUMMARY OF WORK 01 11 00.01 SITE, CIVIL, UTILITIES, AND LANDSCAPING SUMMARY OF WORK 01 11 00.02 ARCHITECTURAL AND INTERIOR DESIGN SUMMARY OF WORK 01 11 00.03 STRUCTURAL SUMMARY OF WORK 01 11 00.04 MECHANICAL AND PLUMBING SUMMARY OF WORK 01 11 00.05 FIRE PROTECTION SUMMARY OF WORK 01 11 00.06 ELECTRICAL AND ELECTRONIC SYSTEMS SUMMARY OF WORK 01 32 01 PROJECT SCHEDULE 01 33 00 SUBMITTAL PROCEDURES 01 33 16 DESIGN DATA (DESIGN AFTER AWARD) 01 33 29 SUSTAINABILITY 01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS 01 42 00 SOURCES FOR REFERENCE PUBLICATIONS 01 45 00.00 10 QUALITY CONTROL 01 45 00.15 10 RESIDENT MANAGEMENT SYSTEM CONTRACTOR MODE(RMS CM) 01 45 35 SPECIAL INSPECTIONS 01 50 00 TEMPORARY CONSTRUCTION FACILITIES AND CONTROLS 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS 01 74 19 CONSTRUCTION AND DEMOLITION WASTE MANAGEMENT 01 78 00 CLOSEOUT SUBMITTALS 01 78 23 OPERATION AND MAINTENANCE DATA DIVISION 02 - EXISTING CONDITIONS 02 41 00 DEMOLITION DIVISION 03 - CONCRETE 03 30 00 CAST-IN-PLACE CONCRETE 03 42 13.00 10 PLANT-PRECAST CONCRETE PRODUCTS FOR BELOW GRADE CONSTRUCTION DIVISION 05 - METALS 05 05 23.16 STRUCTURAL WELDING 05 12 00 STRUCTURAL STEEL 05 21 00 STEEL JOIST FRAMING 05 30 00 STEEL DECKS 05 40 00 COLD-FORMED METAL FRAMING PROJECT TABLE OF CONTENTS Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% DIVISION 13 - SPECIAL CONSTRUCTION 13 34 19 METAL BUILDING SYSTEMS DIVISION 31 - EARTHWORK 31 00 00 EARTHWORK 31 05 22 GEOTEXTILES USED AS FILTERS 31 11 00 CLEARING AND GRUBBING 31 31 16.13 CHEMICAL TERMITE CONTROL DIVISION 32 - EXTERIOR IMPROVEMENTS 32 01 19 FIELD MOLDED SEALANTS FOR SEALING JOINTS IN RIGID PAVEMENTS 32 05 33 LANDSCAPE ESTABLISHMENT 32 11 23 AGGREGATE BASE COURSES 32 13 13.06 PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS AND SITE FACILITIES 32 16 19 CONCRETE CURBS, GUTTERS AND SIDEWALKS 32 17 23 PAVEMENT MARKINGS 32 31 13 CHAIN LINK FENCES AND GATES 32 92 19 SEEDING 32 92 23 SODDING DIVISION 33 - UTILITIES 33 40 00 STORM DRAINAGE UTILITIES 33 71 02 UNDERGROUND ELECTRICAL DISTRIBUTION 33 82 00 TELECOMMUNICATIONS OUTSIDE PLANT (OSP) -- End of Project Table of Contents -- PROJECT TABLE OF CONTENTS Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 01 57 19 TEMPORARY ENVIRONMENTAL CONTROLS 11/15 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. U.S. NATIONAL ARCHIVES AND RECORDS ADMINISTRATION (NARA) 29 CFR 1910.120 Hazardous Waste Operations and Emergency Response 40 CFR 112 Oil Pollution Prevention 40 CFR 122.26 Storm Water Discharges (Applicable to State NPDES Programs, see section 123.25) 40 CFR 152 Pesticide Registration and Classification Procedures 40 CFR 152 - 186 Pesticide Programs 40 CFR 241 Guidelines for Disposal of Solid Waste 40 CFR 243 Guidelines for the Storage and Collection of Residential, Commercial, and Institutional Solid Waste 40 CFR 258 Subtitle D Landfill Requirements 40 CFR 260 Hazardous Waste Management System: General 40 CFR 261 Identification and Listing of Hazardous Waste 40 CFR 261.7 Residues of Hazardous Waste in Empty Containers 40 CFR 262 Standards Applicable to Generators of Hazardous Waste 40 CFR 263 Standards Applicable to Transporters of Hazardous Waste 40 CFR 264 Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities 40 CFR 265 Interim Status Standards for Owners and Operators of Hazardous Waste Treatment, Storage, and Disposal Facilities 40 CFR 266 Standards for the Management of Specific SECTION 01 57 19 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Hazardous Wastes and Specific Types of Hazardous Waste Management Facilities 40 CFR 268 Land Disposal Restrictions 40 CFR 273 Standards For Universal Waste Management 40 CFR 273.2 Standards for Universal Waste Management - Batteries 40 CFR 273.4 Standards for Universal Waste Management - Mercury Containing Equipment 40 CFR 273.5 Standards for Universal Waste Management - Lamps 40 CFR 279 Standards for the Management of Used Oil 40 CFR 300 National Oil and Hazardous Substances Pollution Contingency Plan 40 CFR 300.125 National Oil and Hazardous Substances Pollution Contingency Plan - Notification and Communications 40 CFR 355 Emergency Planning and Notification 40 CFR 403 General Pretreatment Regulations for Existing and New Sources of Pollution 40 CFR 50 National Primary and Secondary Ambient Air Quality Standards 40 CFR 60 Standards of Performance for New Stationary Sources 40 CFR 63 National Emission Standards for Hazardous Air Pollutants for Source Categories 40 CFR 64 Compliance Assurance Monitoring 49 CFR 171 General Information, Regulations, and Definitions 49 CFR 172 Hazardous Materials Table, Special Provisions, Hazardous Materials Communications, Emergency Response Information, and Training Requirements 49 CFR 173 Shippers - General Requirements for Shipments and Packagings 49 CFR 178 Specifications for Packagings 1.2 DEFINITIONS 1.2.1 Class I and II Ozone Depleting Substance (ODS) Class I ODS is defined in Section 602(a) of The Clean Air Act. A list of SECTION 01 57 19 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Class I ODS can be found on the EPA website at the following weblink. http://www.epa.gov/ozone/science/ods/classone.html. Class II ODS is defined in Section 602(s) of The Clean Air Act. A list of Class II ODS can be found on the EPA website at the following weblink. http://www.epa.gov/ozone/science/ods/classtwo.html. 1.2.2 Contractor Generated Hazardous Waste Contractor generated hazardous waste is materials that, if abandoned or disposed of, may meet the definition of a hazardous waste. These waste streams would typically consist of material brought on site by the Contractor to execute work, but are not fully consumed during the course of construction. Examples include, but are not limited to, excess paint thinners (i.e. methyl ethyl ketone, toluene), waste thinners, excess paints, excess solvents, waste solvents, excess pesticides, and contaminated pesticide equipment rinse water. 1.2.3 Debris Debris is non-hazardous solid material generated during the construction, demolition, or renovation of a structure that exceeds 2.5-inch particle size that is: a manufactured object; plant or animal matter; or natural geologic material (for example, cobbles and boulders), broken or removed concrete, masonry, and rock asphalt paving; ceramics; roofing paper and shingles. Inert materials may be reinforced with or contain ferrous wire, rods, accessories and weldments. A mixture of debris and other material such as soil or sludge is also subject to regulation as debris if the mixture is comprised primarily of debris by volume, based on visual inspection. 1.2.4 Electronics Waste Electronics waste is discarded electronic devices intended for salvage, recycling, or disposal. 1.2.5 Environmental Pollution and Damage Environmental pollution and damage is the presence of chemical, physical, or biological elements or agents which adversely affect human health or welfare; unfavorably alter ecological balances of importance to human life; affect other species of importance to humankind; or degrade the environment aesthetically, culturally or historically. 1.2.6 Environmental Protection Environmental protection is the prevention/control of pollution and habitat disruption that may occur to the environment during construction. The control of environmental pollution and damage requires consideration of land, water, and air; biological and cultural resources; and includes management of visual aesthetics; noise; solid, chemical, gaseous, and liquid waste; radiant energy and radioactive material as well as other pollutants. 1.2.7 Green Waste Green waste is the vegetative matter from landscaping, land clearing and grubbing, including, but not limited to, grass, bushes, scrubs, small trees and saplings, tree stumps and plant roots. Marketable trees, SECTION 01 57 19 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% grasses and plants that are indicated to remain, be re-located, or be re-used are not included. 1.2.8 Hazardous Debris As defined in paragraph SOLID WASTE, debris that contains listed hazardous waste (either on the debris surface, or in its interstices, such as pore structure) in accordance with 40 CFR 261. Hazardous debris also includes debris that exhibits a characteristic of hazardous waste in accordance with 40 CFR 261. 1.2.9 Hazardous Materials Hazardous materials as defined in 49 CFR 171 and listed in 49 CFR 172. Hazardous material is any material that: Is regulated as a hazardous material in accordance with 49 CFR 173; or requires a Safety Data Sheet (SDS) in accordance with 29 CFR 1910.120; or during end use, treatment, handling, packaging, storage, transportation, or disposal meets or has components that meet or have potential to meet the definition of a hazardous waste as defined by 40 CFR 261 Subparts A, B, C, or D. Designation of a material by this definition, when separately regulated or controlled by other sections or directives, does not eliminate the need for adherence to that hazard-specific guidance which takes precedence over this section for "control" purposes. Such material includes ammunition, weapons, explosive actuated devices, propellants, pyrotechnics, chemical and biological warfare materials, medical and pharmaceutical supplies, medical waste and infectious materials, bulk fuels, radioactive materials, and other materials such as asbestos, mercury, and polychlorinated biphenyls (PCBs). 1.2.10 Hazardous Waste Hazardous Waste is any material that meets the definition of a solid waste and exhibit a hazardous characteristic (ignitability, corrosivity, reactivity, or toxicity) as specified in 40 CFR 261, Subpart C, or contains a listed hazardous waste as identified in 40 CFR 261, Subpart D. 1.2.11 Installation Pest Management Coordinator Installation Pest Management Coordinator (IPMC) is the individual officially designated by the Installation Commander to oversee the Installation Pest Management Program and the Installation Pest Management Plan. 1.2.12 Land Application Land Application means spreading or spraying discharge water at a rate that allows the water to percolate into the soil. No sheeting action, soil erosion, discharge into storm sewers, discharge into defined drainage areas, or discharge into the "waters of the United States" must occur. Comply with federal, state, and local laws and regulations. 1.2.13 Material not regulated as solid waste Material not regulated as solid waste is nuclear source or byproduct materials regulated under the Federal Atomic Energy Act of 1954 as amended; suspended or dissolved materials in domestic sewage effluent or irrigation return flows, or other regulated point source discharges; SECTION 01 57 19 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% regulated air emissions; and fluids or wastes associated with natural gas or crude oil exploration or production. 1.2.14 Municipal Separate Storm Sewer System (MS4) Permit MS4 permits are those held by installations to obtain NPDES permit coverage for their stormwater discharges. 1.2.15 National Pollutant Discharge Elimination System (NPDES) The NPDES permit program controls water pollution by regulating point sources that discharge pollutants into waters of the United States. 1.2.16 Non-Hazardous Waste Non-hazardous waste is waste that is excluded from, or does not meet, hazardous waste criteria in accordance with 40 CFR 263. 1.2.17 Oily Waste Oily waste are those materials that are, or were, mixed with Petroleum, Oils, and Lubricants (POLs) and have become separated from that POLs. Oily wastes also means materials, including wastewaters, centrifuge solids, filter residues or sludges, bottom sediments, tank bottoms, and sorbents which have come into contact with and have been contaminated by, POLs and may be appropriately tested and discarded in a manner which is in compliance with other state and local requirements. This definition includes materials such as oily rags, "kitty litter" sorbent clay and organic sorbent material. These materials may be land filled provided that: It is not prohibited in other state regulations or local ordinances; the amount generated is "de minimus" (a small amount); it is the result of minor leaks or spills resulting from normal process operations; and free-flowing oil has been removed to the practicable extent possible. Large quantities of this material, generated as a result of a major spill or in lieu of proper maintenance of the processing equipment, are a solid waste. As a solid waste, perform a hazardous waste determination prior to disposal. As this can be an expensive process, it is recommended that this type of waste be minimized through good housekeeping practices and employee education. 1.2.18 Pesticide Pesticide is any substance or mixture of substances intended for preventing, destroying, repelling, or mitigating any pest, or intended for use as a plant regulator, defoliant or desiccant. 1.2.19 Pesticide Treatment Plan A plan for the prevention, monitoring, and control to eliminate pest infestation. 1.2.20 Pests Pests are arthropods, birds, rodents, nematodes, fungi, bacteria, viruses, algae, snails, marine borers, snakes, weeds and other organisms (except for human or animal disease-causing organisms) that adversely affect readiness, military operations, or the well-being of personnel and animals; attack or damage real property, supplies, equipment, or SECTION 01 57 19 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% vegetation; or are otherwise undesirable. 1.2.21 Project Pesticide Coordinator The Project Pesticide Coordinator (PPC) is an individual who resides at a Civil Works Project office and who is responsible overseeing of pesticide application on project grounds. 1.2.22 Recyclables Recyclables are materials, equipment and assemblies such as doors, windows, door and window frames, plumbing fixtures, glazing and mirrors that are recovered and sold as recyclable, and structural components. It also includes commercial-grade refrigeration equipment with Freon removed, household appliances where the basic material content is metal, clean polyethylene terephthalate bottles, cooking oil, used fuel oil, textiles, high-grade paper products and corrugated cardboard, stackable pallets in good condition, clean crating material, and clean rubber/vehicle tires. Metal meeting the definition of lead contaminated or lead based paint contaminated may be included as recyclable if sold to a scrap metal company. Paint cans that meet the definition of empty containers in accordance with 40 CFR 261.7 may be included as recyclable if sold to a scrap metal company. 1.2.23 Regulated Waste Regulated waste are solid wastes that have specific additional federal, state, or local controls for handling, storage, or disposal. 1.2.24 Scrap Metal This includes scrap and excess ferrous and non-ferrous metals such as reinforcing steel, structural shapes, pipe, and wire that are recovered or collected and disposed of as scrap. Scrap metal meeting the definition of hazardous material or hazardous waste is not included. 1.2.25 Sediment Sediment is soil and other debris that have eroded and have been transported by runoff water or wind. 1.2.26 Solid Waste Solid waste is a solid, liquid, semi-solid or contained gaseous waste. A solid waste can be a hazardous waste, non-hazardous waste, or non-Resource Conservation and Recovery Act (RCRA) regulated waste. Types of solid waste typically generated at construction sites may include: 1.2.27 Stormwater Stormwater is any precipitation in an urban or suburban area that does not evaporate or soak into the ground, but instead collects and flows into storm drains, rivers, and streams. 1.2.28 Surface Discharge Surface discharge means discharge of water into drainage ditches, storm sewers, creeks or "waters of the United States". Surface discharges are discrete, identifiable sources and require a permit from the governing SECTION 01 57 19 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% agency. Comply with federal, state, and local laws and regulations. 1.2.29 Surplus Soil Surplus soil is existing soil that is in excess of what is required for this work, including aggregates intended, but not used, for on-site mixing of concrete, mortars, and paving. Contaminated soil meeting the definition of hazardous material or hazardous waste is not included and must be managed in accordance with paragraph HAZARDOUS MATERIAL MANAGEMENT. 1.2.30 Universal Waste The universal waste regulations streamline collection requirements for certain hazardous wastes in the following categories: batteries, pesticides, mercury-containing equipment (for example, thermostats), and lamps (for example, fluorescent bulbs). The rule is designed to reduce hazardous waste in the municipal solid waste (MSW) stream by making it easier for universal waste handlers to collect these items and send them for recycling or proper disposal. These regulations can be found at 40 CFR 273. 1.2.31 Wastewater Wastewater is the used water and solids from a community that flow to a treatment plant. 1.2.32 Waters of the United States Waters of the United States means Federally jurisdictional waters, including wetlands, that are subject to regulation under Section 404 of the Clean Water Act or navigable waters, as defined under the Rivers and Harbors Act. 1.2.33 Wetlands Wetlands are those areas that are inundated or saturated by surface or groundwater at a frequency and duration sufficient to support, and that under normal circumstances do support, a prevalence of vegetation typically adapted for life in saturated soil conditions. 1.2.34 Wood Wood is dimension and non-dimension lumber, plywood, chipboard, hardboard. Treated or painted wood that meets the definition of lead contaminated or lead based contaminated paint is not included. Treated wood includes, but is not limited to, lumber, utility poles, crossties, and other wood products with chemical treatment. 1.3 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for Contractor Quality Control approval. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-01 Preconstruction Submittals SECTION 01 57 19 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Preconstruction Survey Solid Waste Management Permit; G, RO Regulatory Notifications; G, RO Environmental Protection Plan; G, RO Stormwater Notice of Intent (for NPDES coverage under the general permit for construction activities); G, RO Dirt and Dust Control Plan; G, RO Employee Training Records; G, RO Environmental Manager Qualifications; G, RO SD-06 Test Reports Inspection Reports; G, RO Solid Waste Management Report; G, RO SD-07 Certificates Employee Training Records; G, RO Erosion and Sediment Control Inspector Qualifications; G, RO SD-11 Closeout Submittals Stormwater Pollution Prevention Plan Compliance Notebook; G, RO Stormwater Notice of Termination (for NPDES coverage under the general permit for construction activities); G, RO Waste Determination Documentation; G, RO Disposal Documentation for Hazardous and Regulated Waste; G, RO Assembled Employee Training Records; G, RO Solid Waste Management Permit; G, RO Solid Waste Management Report; G, RO Hazardous Waste/Debris Management; G, RO Regulatory Notifications; G, RO Sales Documentation; G, RO Contractor Certification As-Built Topographic Survey 1.4 ENVIRONMENTAL PROTECTION REQUIREMENTS Provide and maintain, during the life of the contract, environmental protection as defined. Plan for and provide environmental protective measures to control pollution that develops during construction practice. Plan for and provide environmental protective measures required to correct conditions that develop during the construction of permanent or temporary environmental features associated with the project. Protect the environmental resources within the project boundaries and those affected outside the limits of permanent work during the entire duration of this Contract. Comply with federal, state, and local regulations pertaining to the environment, including water, air, solid waste, hazardous waste and substances, oily substances, and noise pollution. Tests and procedures assessing whether construction operations comply with Applicable Environmental Laws may be required. Analytical work must be performed by qualified laboratories; and where required by law, the laboratories must be certified. Perform work under this contract consistent with the policy and objectives identified in the installation's Environmental Management System (EMS). Perform work in a manner that conforms to objectives and targets of the environmental programs and operational controls identified by the EMS. SECTION 01 57 19 Page 8 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Support Government personnel when environmental compliance and EMS audits are conducted by escorting auditors at the Project site, answering questions, and providing proof of records being maintained. Provide monitoring and measurement information as necessary to address environmental performance relative to environmental, energy, and transportation management goals. In the event an EMS nonconformance or environmental noncompliance associated with the contracted services, tasks, or actions occurs, take corrective and preventative actions. In addition, employees must be aware of their roles and responsibilities under the installation EMS and of how these EMS roles and responsibilities affect work performed under the contract. Coordinate with the installation's EMS coordinator to identify training needs associated with environmental aspects and the EMS, and arrange training or take other action to meet these needs. Provide training documentation to the Contracting Officer. The Installation Environmental Office will retain associated environmental compliance records. Make EMS Awareness training completion certificates available to Government auditors during EMS audits and include the certificates in the Employee Training Records. See paragraph EMPLOYEE TRAINING RECORDS. 1.5 QUALITY ASSURANCE 1.5.1 Preconstruction Survey and Protection of Features This paragraph supplements the Contract Clause PROTECTION OF EXISTING VEGETATION, STRUCTURES, EQUIPMENT, UTILITIES, AND IMPROVEMENTS. Prior to start of any onsite construction activities, perform a Preconstruction Survey of the project site with the Contracting Officer, and take photographs showing existing environmental conditions in and adjacent to the site. Submit a report for the record. Include in the report a plan describing the features requiring protection under the provisions of the Contract Clauses, which are not specifically identified on the drawings as environmental features requiring protection along with the condition of trees, shrubs and grassed areas immediately adjacent to the site of work and adjacent to the Contractor's assigned storage area and access route(s), as applicable. The Contractor and the Contracting Officer will sign this survey report upon mutual agreement regarding its accuracy and completeness. Protect those environmental features included in the survey report and any indicated on the drawings, regardless of interference that their preservation may cause to the work under the Contract. 1.5.2 Regulatory Notifications Provide regulatory notification requirements in accordance with federal, state and local regulations. In cases where the Government will also provide public notification (such as stormwater permitting), coordinate with the Contracting Officer. Submit copies of regulatory notifications to the Contracting Officer within 21 days prior to commencement of work activities. Typically, regulatory notifications must be provided for the following (this listing is not all-inclusive): demolition, renovation, NPDES defined site work, construction, removal or use of a permitted air emissions source, and remediation of controlled substances (asbestos, hazardous waste, lead paint). 1.5.3 Environmental Brief Attend an environmental brief to be included in the preconstruction meeting. Provide the following information: types, quantities, and use of SECTION 01 57 19 Page 9 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% hazardous materials that will be brought onto the installation; and types and quantities of wastes/wastewater that may be generated during the Contract. Discuss the results of the Preconstruction Survey at this time. Prior to initiating any work on site, meet with the Contracting Officer and installation Environmental Office to discuss the proposed Environmental Protection Plan (EPP). Develop a mutual understanding relative to the details of environmental protection, including measures for protecting natural and cultural resources, required reports, required permits, permit requirements (such as mitigation measures), and other measures to be taken. 1.5.4 Environmental Manager Appoint in writing an Environmental Manager for the project site. The Environmental Manager is directly responsible for coordinating contractor compliance with federal, state, local, and installation requirements. The Environmental Manager must ensure compliance with Hazardous Waste Program requirements (including hazardous waste handling, storage, manifesting, and disposal); implement the EPP; ensure environmental permits are obtained, maintained, and closed out; ensure compliance with Stormwater Program requirements; ensure compliance with Hazardous Materials (storage, handling, and reporting) requirements; and coordinate any remediation of regulated substances (lead, asbestos, PCB transformers). This can be a collateral position; however, the person in this position must be trained to adequately accomplish the following duties: ensure waste segregation and storage compatibility requirements are met; inspect and manage Satellite Accumulation areas; ensure only authorized personnel add wastes to containers; ensure Contractor personnel are trained in 40 CFR requirements in accordance with their position requirements; coordinate removal of waste containers; and maintain the Environmental Records binder and required documentation, including environmental permits compliance and close-out. Submit Environmental Manager Qualifications to the Contracting Officer. 1.5.5 Employee Training Records Prepare and maintain Employee Training Records throughout the term of the contract meeting applicable 40 CFR requirements. Provide Employee Training Records in the Environmental Records Binder. Submit these Assembled Employee Training Records to the Contracting Officer at the conclusion of the project, unless otherwise directed. Train personnel to meet EPA and state requirements. Conduct environmental protection/pollution control meetings for personnel prior to commencing construction activities. Contact additional meetings for new personnel and when site conditions change. Include in the training and meeting agenda: methods of detecting and avoiding pollution; familiarization with statutory and contractual pollution standards; installation and care of devices, vegetative covers, and instruments required for monitoring purposes to ensure adequate and continuous environmental protection/pollution control; anticipated hazardous or toxic chemicals or wastes, and other regulated contaminants; recognition and protection of archaeological sites, artifacts, waters of the United States, and endangered species and their habitat that are known to be in the area. Provide copy of the Erosion and Sediment Control Inspector Qualifications as defined by EPA and Certification as required by North Carolina. SECTION 01 57 19 Page 10 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.5.6 Non-Compliance Notifications The Contracting Officer will notify the Contractor in writing of any observed noncompliance with federal, state or local environmental laws or regulations, permits, and other elements of the Contractor's EPP. After receipt of such notice, inform the Contracting Officer of the proposed corrective action and take such action when approved by the Contracting Officer. The Contracting Officer may issue an order stopping all or part of the work until satisfactory corrective action has been taken. No time extensions will be granted or equitable adjustments allowed for any such suspensions. This is in addition to any other actions the Contracting Officer may take under the contract, or in accordance with the Federal Acquisition Regulation or Federal Law. 1.6 ENVIRONMENTAL PROTECTION PLAN The purpose of the EPP is to present an overview of known or potential environmental issues that must be considered and addressed during construction. Incorporate construction related objectives and targets from the installation's EMS into the EPP. Include in the EPP measures for protecting natural and cultural resources, required reports, and other measures to be taken. Meet with the Contracting Officer or Contracting Officer Representative to discuss the EPP and develop a mutual understanding relative to the details for environmental protection including measures for protecting natural resources, required reports, and other measures to be taken. Submit the EPP within 15 days after notice to proceed and not less than 15 days before the preconstruction meeting. Revise the EPP throughout the project to include any reporting requirements, changes in site conditions, or contract modifications that change the project scope of work in a way that could have an environmental impact. No requirement in this section will relieve the Contractor of any applicable federal, state, and local environmental protection laws and regulations. During Construction, identify, implement, and submit for approval any additional requirements to be included in the EPP. Maintain the current version onsite. The EPP includes, but is not limited to, the following elements: 1.6.1 General Overview and Purpose 1.6.1.1 Descriptions A brief description of each specific plan required by environmental permit or elsewhere in this Contract such as stormwater pollution prevention plan, spill control plan, solid waste management plan, wastewater management plan, air pollution control plan, contaminant prevention plan, pesticide treatment plan, a historical, archaeological, cultural resources, biological resources and wetlands plan, traffic control plan Non-Hazardous Solid Waste Disposal Plan and borrowing material plan. 1.6.1.2 Duties The duties and level of authority assigned to the person(s) on the job site who oversee environmental compliance, such as who is responsible for adherence to the EPP, who is responsible for spill cleanup and training personnel on spill response procedures, who is responsible for manifesting hazardous waste to be removed from the site (if applicable), and who is responsible for training the Contractor's environmental protection personnel. SECTION 01 57 19 Page 11 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.6.1.3 Procedures A copy of any standard or project-specific operating procedures that will be used to effectively manage and protect the environment on the project site. 1.6.1.4 Communications Communication and training procedures that will be used to convey environmental management requirements to Contractor employees and subcontractors. 1.6.1.5 Contact Information Emergency contact information contact information (office phone number, cell phone number, and e-mail address). 1.6.2 General Site Information 1.6.2.1 Drawings Drawings showing locations of proposed temporary excavations or embankments for haul roads, stream crossings, jurisdictional wetlands, material storage areas, structures, sanitary facilities, storm drains and conveyances, and stockpiles of excess soil. 1.6.2.2 Work Area Work area plan showing the proposed activity in each portion of the area and identify the areas of limited use or nonuse. Include measures for marking the limits of use areas, including methods for protection of features to be preserved within authorized work areas and methods to control runoff and to contain materials on site, and a traffic control plan. 1.6.2.3 Documentation A letter signed by an officer of the firm appointing the Environmental Manager and stating that person is responsible for managing and implementing the Environmental Program as described in this contract. Include in this letter the Environmental Manager's authority to direct the removal and replacement of non-conforming work. 1.6.3 Management of Natural Resources a. Land resources b. Tree protection c. Replacement of damaged landscape features d. Temporary construction e. Stream crossings f. Fish and wildlife resources g. Wetland areas SECTION 01 57 19 Page 12 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.6.4 Protection of Historical and Archaeological Resources a. Objectives b. Methods 1.6.5 Stormwater Management and Control a. Ground cover b. Erodible soils c. Temporary measures (1) Structural Practices (2) Temporary and permanent stabilization d. Effective selection, implementation and maintenance of Best Management Practices (BMPs). 1.6.6 Protection of the Environment from Waste Derived from Contractor Operations Control and disposal of solid and sanitary waste. Control and disposal of hazardous waste. This item consist of the management procedures for hazardous waste to be generated. The elements of those procedures will coincide with the Installation Hazardous Waste Management Plan. The Contracting Officer will provide a copy of the Installation Hazardous Waste Management Plan. As a minimum, include the following: a. List of the types of hazardous wastes expected to be generated b. Procedures to ensure a written waste determination is made for appropriate wastes that are to be generated c. Sampling/analysis plan, including laboratory method(s) that will be used for waste determinations and copies of relevant laboratory certifications d. Methods and proposed locations for hazardous waste accumulation/storage (that is, in tanks or containers) e. Management procedures for storage, labeling, transportation, and disposal of waste (treatment of waste is not allowed unless specifically noted) f. Management procedures and regulatory documentation ensuring disposal of hazardous waste complies with Land Disposal Restrictions (40 CFR 268 ) g. Management procedures for recyclable hazardous materials such as lead-acid batteries, used oil, and similar h. Used oil management procedures in accordance with 40 CFR 279; Hazardous waste minimization procedures SECTION 01 57 19 Page 13 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% i. Plans for the disposal of hazardous waste by permitted facilities; and Procedures to be employed to ensure required employee training records are maintained. 1.6.7 Prevention of Releases to the Environment Procedures to prevent releases to the environment Notifications in the event of a release to the environment 1.6.8 Regulatory Notification and Permits List what notifications and permit applications must be made. Some permits require up to 180 days to obtain. Demonstrate that those permits have been obtained or applied for by including copies of applicable environmental permits. The EPP will not be approved until the permits have been obtained. 1.6.9 Clean Air Act Compliance 1.6.9.1 Haul Route Submit truck and material haul routes and a Dirt and Dust Control Plan for controlling dirt, debris, and dust on Installation roadways. As a minimum, identify in the plan the subcontractor and equipment for cleaning along the haul route and measures to reduce dirt, dust, and debris from roadways. 1.6.9.2 Pollution Generating Equipment Identify air pollution generating equipment or processes that may require federal, state, or local permits under the Clean Air Act. Determine requirements based on any current installation permits and the impacts of the project. Provide a list of all fixed or mobile equipment, machinery or operations that could generate air emissions during the project to the Installation Environmental Office (Air Program Manager). 1.6.9.3 Stationary Internal Combustion Engines Identify portable and stationary internal combustion engines that will be supplied, used or serviced. Comply with 40 CFR 60 Subpart IIII, 40 CFR 60 Subpart JJJJ, 40 CFR 63 Subpart ZZZZ, and local regulations as applicable. At minimum, include the make, model, serial number, manufacture date, size (engine brake horsepower), and EPA emission certification status of each engine. Maintain applicable records and log hours of operation and fuel use. Logs must include reasons for operation and delineate between emergency and non-emergency operation. 1.6.9.4 Refrigerants Identify management practices to ensure that heating, ventilation, and air conditioning (HVAC) work involving refrigerants complies with 40 CFR 82 requirements. Technicians must be certified, maintain copies of certification on site, use certified equipment and log work that requires the addition or removal of refrigerant. Any refrigerant reclaimed is the property of the Government, coordinate with the Installation Environmental Office to determine the appropriate turn in location. SECTION 01 57 19 Page 14 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.6.9.5 Air Pollution-engineering Processes Identify planned air pollution-generating processes and management control measures (including, but not limited to, spray painting, abrasive blasting, demolition, material handling, fugitive dust, and fugitive emissions). Log hours of operations and track quantities of materials used. 1.6.9.6 Compliant Materials Provide the Government a list of and SDSs for all hazardous materials proposed for use on site. Materials must be compliant with all Clean Air Act regulations for emissions including solvent and volatile organic compound contents, and applicable National Emission Standards for Hazardous Air Pollutants requirements. The Government may alter or limit use of specific materials as needed to meet installation permit requirements for emissions. 1.7 LICENSES AND PERMITS Obtain licenses and permits required for the construction of the project and in accordance with FAR 52.236-7. Notify the Government of all general use permitted equipment the Contractor plans to use on site. This paragraph supplements the Contractor's responsibility under FAR 52.236-7. 1.8 ENVIRONMENTAL RECORDS BINDER Maintain on-site a separate three-ring Environmental Records Binder and submit at the completion of the project. Make separate parts within the binder that correspond to each submittal listed under paragraph CLOSEOUT SUBMITTALS in this section. 1.9 PESTICIDE DELIVERY, STORAGE, AND HANDLING 1.9.1 Delivery and Storage Deliver pesticides to the site in the original, unopened containers bearing legible labels indicating the EPA registration number and the manufacturer's registered uses. Store pesticides according to manufacturer's instructions and under lock and key when unattended. 1.9.2 Handling Requirements Formulate, treat with, and dispose of pesticides and associated containers in accordance with label directions and use the clothing and personal protective equipment specified on the labeling for use during each phases of the application. Furnish SDSs for pesticide products. 1.10 SOLID WASTE MANAGEMENT PERMIT Provide the Contracting Officer with written notification of the quantity of anticipated solid waste or debris that is anticipated or estimated to be generated by construction. Include in the report the locations where various types of waste will be disposed or recycled. Include letters of acceptance from the receiving location or as applicable; submit one copy of the receiving location state and local Solid Waste Management Permit or license showing such agency's approval of the disposal plan before transporting wastes off Government property. SECTION 01 57 19 Page 15 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.11 SOLID WASTE MANAGEMENT REPORT Monthly, submit a solid waste disposal report to the Contracting Officer. For each waste, the report will state the classification (using the definitions provided in this Section), amount, location, and name of the business receiving the solid waste. PART 2 PRODUCTS Not used. PART 3 EXECUTION 3.1 PROTECTION OF NATURAL RESOURCES Minimize interference with, disturbance to, and damage to fish, wildlife, and plants, including their habitats. Prior to the commencement of activities, consult with the Installation Environmental Office, regarding rare species or sensitive habitats that need to be protected. The protection of rare, threatened, and endangered animal and plant species identified, including their habitats, is the Contractor's responsibility. Preserve the natural resources within the project boundaries and outside the limits of permanent work. Restore to an equivalent or improved condition upon completion of work that is consistent with the requirements of the Installation Environmental Office or as otherwise specified. Confine construction activities to within the limits of the work indicated or specified. 3.1.1 Flow Ways Do not alter water flows or otherwise significantly disturb the native habitat adjacent to the project and critical to the survival of fish and wildlife, except as specified and permitted. 3.1.2 Vegetation Except in areas to be cleared, do not remove, cut, deface, injure, or destroy trees or shrubs without the Contracting Officer's permission. Do not fasten or attach ropes, cables, or guys to existing nearby trees for anchorages unless authorized by the Contracting Officer. Where such use of attached ropes, cables, or guys is authorized, the Contractor is responsible for any resultant damage. Protect existing trees that are to remain to ensure they are not injured, bruised, defaced, or otherwise damaged by construction operations. Remove displaced rocks from uncleared areas. Coordinate with the Contracting Officer and Installation Environmental Office to determine appropriate action for trees and other landscape features scarred or damaged by equipment operations. 3.1.3 Streams Stream crossings must allow movement of materials or equipment without violating water pollution control standards of the federal, state, and local governments. Construction of stream crossing structures must be in compliance with any required permits including, but not limited to, Clean Water Act Section 404, and Section 401 Water Quality. SECTION 01 57 19 Page 16 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% The Contracting Officer's approval and appropriate permits are required before any equipment will be permitted to ford live streams. In areas where frequent crossings are required, install temporary culverts or bridges. Obtain Contracting Officer's approval prior to installation. Remove temporary culverts or bridges upon completion of work, and repair the area to its original condition unless otherwise required by the Contracting Officer. 3.2 STORMWATER Do not discharge stormwater from construction sites to the sanitary sewer. If the water is noted or suspected of being contaminated, it may only be released to the storm drain system if the discharge is specifically permitted. Obtain authorization in advance from the Installation Environmental Office for any release of contaminated water. 3.2.1 Construction General Permit Provide a Construction General Permit as required by 40 CFR 122.26 or the State of North Carolina General Permit. Under the terms and conditions of the permit, install, inspect, maintain BMPs, prepare stormwater erosion and sediment control inspection reports, and submit SWPPP inspection reports. Maintain construction operations and management in compliance with the terms and conditions of the general permit for stormwater discharges from construction activities. 3.2.1.1 Stormwater Pollution Prevention Plan Submit a project-specific Stormwater Pollution Prevention Plan (SWPPP) to the Contracting Officer for approval, prior to the commencement of work. The SWPPP must meet the requirements of 40 CFR 122.26 the North Carolina State General Permit for stormwater discharges from construction sites. Include the following: a. Comply with terms of the state general permit for stormwater discharges from construction activities. Prepare SWPPP in accordance with North CArolina requirements. Use North Carolina http://deq.nc.gov/about/divisions/water-resources and EPA guide: Developing your Stormwater Pollution Prevention Plan located at http://water.epa.gov/polwaste/npdes/stormwater/Stormwater-Pollution- Prevention-Plans-for-Construction-Activities.cfm to prepare the SWPPP. b. Select applicable BMPs from EPA Fact Sheets located at http://water.epa.gov/polwaste/npdes/swbmp/Construction-Site-StormWater- Run-Off-Control.cfm or in accordance with applicable state or local requirements. c. Include a completed copy of the Notice of Intent, BMP Inspection Report Template, and Stormwater Notice of Termination, except for the effective date. 3.2.1.2 Stormwater Notice of Intent for Construction Activities Prepare and submit the Notice of Intent for NPDES coverage under the general permit for construction activities to the Contracting Officer for review and approval. Prepare and submit a Notice of Intent as a co-permittee to the Contracting Officer, for review and approval. SECTION 01 57 19 Page 17 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Submit the approved NOI and appropriate permit fees onto the appropriate federal or state agency for approval. No land disturbing activities may commence without permit coverage. Maintain an approved copy of the SWPPP at the onsite construction office, and continually update as regulations require, reflecting current site conditions. 3.2.1.3 Inspection Reports Submit "Inspection Reports" to the Contracting Officer in accordance with the State of North Caroina Construction General Permit. 3.2.1.4 Stormwater Pollution Prevention Plan Compliance Notebook Create and maintain a three ring binder of documents that demonstrate compliance with the Construction General Permit. Include a copy of the permit Notice of Intent, proof of permit fee payment, SWPPP and SWPPP update amendments, inspection reports and related corrective action records, copies of correspondence with the North carolina State Permitting Agency, and a copy of the permit Notice of Termination in the binder. At project completion, the notebook becomes property of the Government. Provide the compliance notebook to the Contracting Officer. 3.2.1.5 Stormwater Notice of Termination for Construction Activities Submit a Notice of Termination to the Contracting Officer for approval once construction is complete and final stabilization has been achieved on all portions of the site for which the permittee is responsible. Once approved, submit the Notice of Termination to the appropriate state or federal agency. Prepare as-built topographic survey information required by the permitting agency for certification of the stormwater management system, and provide to the Contracting Officer. 3.2.2 Erosion and Sediment Control Measures Provide erosion and sediment control measures in accordance with state and local laws and regulations. Preserve vegetation to the maximum extent practicable. Erosion control inspection reports may be compiled as part of a stormwater pollution prevention plan inspection reports. 3.2.2.1 Erosion Control Prevent erosion by mulching, Compost Blankets, Geotextiles, temporary slope drains as needed. Stabilize slopes by sodding, seeding, or such combination of these methods necessary for effective erosion control. Use of hay bales is prohibited. 3.2.2.2 Sediment Control Practices Implement sediment control practices to divert flows from exposed soils, temporarily store flows, or otherwise limit runoff and the discharge of pollutants from exposed areas of the site. Implement sediment control practices prior to soil disturbance and prior to creating areas with concentrated flow, during the construction process to minimize erosion and sediment laden runoff. Include the following devices: silt fence, temporary diversion dikes, and/or storm drain inlet protection. SECTION 01 57 19 Page 18 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.2.3 Work Area Limits Mark the areas that need not be disturbed under this Contract prior to commencing construction activities. Mark or fence isolated areas within the general work area that are not to be disturbed. Protect monuments and markers before construction operations commence. Where construction operations are to be conducted during darkness, any markers must be visible in the dark. Personnel must be knowledgeable of the purpose for marking and protecting particular objects. 3.2.4 Contractor Facilities and Work Areas Place field offices, staging areas, stockpile storage, and temporary buildings in areas designated on the drawings or as directed by the Contracting Officer. Move or relocate the Contractor facilities only when approved by the Government. Provide erosion and sediment controls for onsite borrow and spoil areas to prevent sediment from entering nearby waters. Control temporary excavation and embankments for plant or work areas to protect adjacent areas. 3.2.5 Municipal Separate Storm Sewer System (MS4) Management Comply with the Installation's MS4 permit requirements. 3.3 SURFACE AND GROUNDWATER 3.3.1 Cofferdams, Diversions, and Dewatering Construction operations for dewatering, must be constantly controlled to maintain compliance with existing state water quality standards and designated uses of the surface water body. Comply with the State of North Carolina water quality standards and anti-degradation provisions and the Clean Water Act Section 404. Do not discharge excavation ground water to the sanitary sewer, storm drains, or to surface waters without prior specific authorization in writing from the Installation Environmental Office. Discharge of hazardous substances will not be permitted under any circumstances. Use sediment control BMPs to prevent construction site runoff from directly entering any storm drain or surface waters. If the construction dewatering is noted or suspected of being contaminated, it may only be released to the storm drain system if the discharge is specifically permitted. Obtain authorization for any contaminated groundwater release in advance from the Installation Environmental Officer and the federal or state authority, as applicable. Discharge of hazardous substances will not be permitted under any circumstances. 3.3.2 Waters of the United States Do not enter, disturb, destroy, or allow discharge of contaminants into waters of the United States. The protection of waters of the United States shown on the drawings in accordance with paragraph LICENSES AND PERMITS is the Contractor's responsibility. Authorization to enter specific waters of the United States identified does not relieve the Contractor from any obligation to protect other waters of the United States within, adjacent to, or in the vicinity of the construction site and associated boundaries. SECTION 01 57 19 Page 19 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.4 PROTECTION OF CULTURAL RESOURCES 3.4.1 Archaeological Resources Existing archaeological resources within the work area are shown on the drawings. Protect these resources and be responsible for their preservation during the life of the Contract. If, during excavation or other construction activities, any previously unidentified or unanticipated historical, archaeological, and cultural resources are discovered or found, activities that may damage or alter such resources will be suspended. Resources covered by this paragraph include, but are not limited to: any human skeletal remains or burials; artifacts; shell, midden, bone, charcoal, or other deposits; rock or coral alignments, pavings, wall, or other constructed features; and any indication of agricultural or other human activities. Upon such discovery or find, immediately notify the Contracting Officer so that the appropriate authorities may be notified and a determination made as to their significance and what, if any, special disposition of the finds should be made. Cease all activities that may result in impact to or the destruction of these resources. Secure the area and prevent employees or other persons from trespassing on, removing, or otherwise disturbing such resources. The Government retains ownership and control over archaeological resources. 3.4.2 Historical Resources Existing historical resources within the work area are shown on the drawings. Protect these resources and be responsible for their preservation during the life of the Contract. 3.5 AIR RESOURCES Equipment operation, activities, or processes will be in accordance with 40 CFR 64 and state air emission and performance laws and standards. 3.5.1 Preconstruction Air Permits Notify the Air Program Manager, through the Contracting Officer, at least 6 months prior to bringing equipment, assembled or unassembled, onto the Installation, so that air permits can be secured. Necessary permitting time must be considered in regard to construction activities. Clean Air Act (CAA) permits must be obtained prior to bringing equipment, assembled or unassembled, onto the Installation. 3.5.2 Oil or Dual-fuel Boilers and Furnaces Provide product data and details for new, replacement, or relocated fuel fired boilers, heaters, or furnaces to the Installation Environmental Office (Air Program Manager) through the Contracting Officer. Data to be reported include: equipment purpose (water heater, building heat, process), manufacturer, model number, serial number, fuel type (oil type, gas type) size (MMBTU heat input). Provide in accordance with paragraph PRECONSTRUCTION AIR PERMITS. 3.5.3 Burning Burning is prohibited on the Government premises. SECTION 01 57 19 Page 20 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.5.4 Accidental Venting of Refrigerant Accidental venting of a refrigerant is a release and must be reported immediately to the Contracting Officer. 3.5.5 EPA Certification Requirements Heating and air conditioning technicians must be certified through an EPA-approved program. Maintain copies of certifications at the employees' places of business; technicians must carry certification wallet cards, as provided by environmental law. 3.5.6 Dust Control Keep dust down at all times, including during nonworking periods. Sprinkle or treat, with dust suppressants, the soil at the site, haul routes, and other areas disturbed by operations. Dry power brooming will not be permitted. Instead, use vacuuming, wet mopping, wet sweeping, or wet power brooming. Air blowing will be permitted only for cleaning nonparticulate debris such as steel reinforcing bars. Only wet cutting will be permitted for cutting concrete blocks, concrete, and bituminous concrete. Do not unnecessarily shake bags of cement, concrete mortar, or plaster. Silica-containing dusts must be maintained and monitored in compliance with the OSHA Silica Standard for Construction (2016) 3.5.6.1 Particulates Dust particles, aerosols and gaseous by-products from construction activities, and processing and preparation of materials (such as from asphaltic batch plants) must be controlled at all times, including weekends, holidays, and hours when work is not in progress. Maintain excavations, stockpiles, haul routes, permanent and temporary access roads, plant sites, spoil areas, borrow areas, and other work areas within or outside the project boundaries free from particulates that would exceed 40 CFR 50, state, and local air pollution standards or that would cause a hazard or a nuisance. Sprinkling, chemical treatment of an approved type, baghouse, scrubbers, electrostatic precipitators, or other methods will be permitted to control particulates in the work area. Sprinkling, to be efficient, must be repeated to keep the disturbed area damp. Provide sufficient, competent equipment available to accomplish these tasks. Perform particulate control as the work proceeds and whenever a particulate nuisance or hazard occurs. Comply with state and local visibility regulations. 3.5.6.2 Abrasive Blasting Blasting operations cannot be performed without prior approval of the Installation Air Program Manager. The use of silica sand is prohibited in sandblasting. All silica containing blasting media must be maintained and/or monitored in compliance with the OSHA sSilica Standard for Construction (2016) Provide tarpaulin drop cloths and windscreens to enclose abrasive blasting operations to confine and collect dust, abrasive agent, paint chips, and other debris. 3.5.7 Odors Control odors from construction activities. The odors must be in SECTION 01 57 19 Page 21 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% compliance with state regulations and local ordinances and may not constitute a health hazard. 3.6 WASTE MINIMIZATION Minimize the use of hazardous materials and the generation of waste. Include procedures for pollution prevention/ hazardous waste minimization in the Hazardous Waste Management Section of the EPP. Obtain a copy of the installation's Pollution Prevention/Hazardous Waste Minimization Plan for reference material when preparing this part of the EPP. If no written plan exists, obtain information by contacting the Contracting Officer. Describe the anticipated types of the hazardous materials to be used in the construction when requesting information. 3.6.1 Salvage, Reuse and Recycle Identify anticipated materials and waste for salvage, reuse, and recycling. Describe actions to promote material reuse, resale or recycling. To the extent practicable, all scrap metal must be sent for reuse or recycling and will not be disposed of in a landfill. Include the name, physical address, and telephone number of the hauler, if transported by a franchised solid waste hauler. Include the destination and, unless exempted, provide a copy of the state or local permit (cover) or license for recycling. 3.6.2 Nonhazardous Solid Waste Diversion Report Maintain an inventory of nonhazardous solid waste diversion and disposal of construction and demolition debris. Submit a report to the Contracting Officer on the first working day after each fiscal year quarter, starting the first quarter that nonhazardous solid waste has been generated. Include the following in the report: Construction and Demolition (C&D) Debris Disposed _____ tons, as appropriate C&D Debris Recycled _____ tons, as appropriate Total C&D Debris Generated _____ tons, as appropriate Waste Sent to Waste-To-Energy Incineration Plant (This amount should not be included in the recycled amount) _____ tons, as appropriate 3.7 WASTE MANAGEMENT AND DISPOSAL 3.7.1 Waste Determination Documentation Complete a Waste Determination form (provided at the pre-construction conference) for Contractor-derived wastes to be generated. Potentially hazardous solid waste streams that are not subject to a specific exclusion or exemption from the hazardous waste regulations (e.g. scrap metal, domestic sewage) or subject to special rules, (lead-acid batteries and precious metals) must be characterized in accordance with the requirements of 40 CFR 261 or corresponding applicable state or local regulations. Base waste determination on user knowledge of the processes and materials SECTION 01 57 19 Page 22 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% used, and analytical data when necessary. Consult with the Installation environmental staff for guidance on specific requirements. Attach support documentation to the Waste Determination form. As a minimum, provide a Waste Determination form for the following waste (this listing is not inclusive): oil- and latex -based painting and caulking products, solvents, adhesives, aerosols, petroleum products, and containers of the original materials. 3.7.2 Solid Waste Management 3.7.2.1 Solid Waste Management Report Provide copies of the waste handling facilities' weight tickets, receipts, bills of sale, and other sales documentation. In lieu of sales documentation, a statement indicating the disposal location for the solid waste that is signed by an employee authorized to legally obligate or bind the firm may be submitted. The sales documentation Contractor certification must include the receiver's tax identification number and business, EPA or state registration number, along with the receiver's delivery and business addresses and telephone numbers. For each solid waste retained for the Contractor's own use, submit the information previously described in this paragraph on the solid waste disposal report. Prices paid or received do not have to be reported to the Contracting Officer unless required elsewhere in this Contract or by public law. 3.7.2.2 Control and Management of Solid Wastes Pick up solid wastes, and place in covered containers that are regularly emptied. Do not prepare or cook food on the project site. Prevent contamination of the site and other areas when handling and disposing of wastes. At project completion, leave the areas clean. Employ segregation measures so that no hazardous or toxic waste will become co-mingled with non-hazardous solid waste. Transport solid waste off Government property and dispose of it in compliance with 40 CFR 260, state, and local requirements for solid waste disposal. A Subtitle D RCRA permitted landfill is the minimum acceptable offsite solid waste disposal option. Verify that the selected transporters and disposal facilities have the necessary permits and licenses to operate. Solid waste disposal offsite must comply with most stringent local, state, and federal requirements, including 40 CFR 241, 40 CFR 243, and 40 CFR 258. Manage hazardous material used in construction, including but not limited to, aerosol cans, waste paint, cleaning solvents, contaminated brushes, and used rags, in accordance with 49 CFR 173. 3.7.3 Control and Management of Hazardous Waste Do not dispose of hazardous waste on Government property. Do not discharge any waste to a sanitary sewer, storm drain, or to surface waters or conduct waste treatment or disposal on Government property without written approval of the Contracting Officer. 3.7.3.1 Hazardous Waste/Debris Management Identify construction activities that will generate hazardous waste or debris. Provide a documented waste determination for resultant waste streams. Identify, label, handle, store, and dispose of hazardous waste or debris in accordance with federal, state, and local regulations, SECTION 01 57 19 Page 23 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% including 40 CFR 261, 40 CFR 262, 40 CFR 263, 40 CFR 264, 40 CFR 265, 40 CFR 266, and 40 CFR 268. Manage hazardous waste in accordance with the approved Hazardous Waste Management Section of the EPP. Store hazardous wastes in approved containers in accordance with 49 CFR 173 and 49 CFR 178. Hazardous waste generated within the confines of Government facilities is identified as being generated by the Government. Prior to removal of any hazardous waste from Government property, hazardous waste manifests must be signed by personnel from the Installation Environmental Office. Do not bring hazardous waste onto Government property. Provide the Contracting Officer with a copy of waste determination documentation for any solid waste streams that have any potential to be hazardous waste or contain any chemical constituents listed in 40 CFR 372-SUBPART D. 3.7.3.2 Hazardous Waste Disposal Provide hazardous waste manifest to the Installations Environmental Office for review, approval, and signature prior to shipping waste off Government property. 3.7.3.3 Universal Waste Management Manage the following categories of universal waste in accordance with federal, state, and local requirements and installation instructions: a. Batteries as described in 40 CFR 273.2 b. Lamps as described in 40 CFR 273.5 c. Mercury-containing equipment as described in 40 CFR 273.4 Mercury is prohibited in the construction of this facility, unless specified otherwise, and with the exception of mercury vapor lamps and fluorescent lamps. Dumping of mercury-containing materials and devices such as mercury vapor lamps, fluorescent lamps, and mercury switches, in rubbish containers is prohibited. Remove without breaking, pack to prevent breakage, and transport out of the activity in an unbroken condition for disposal as directed. 3.7.3.4 Electronics End-of-Life Management Recycle or dispose of electronics waste, including, but not limited to, used electronic devices such computers, monitors, hard-copy devices, televisions, mobile devices, in accordance with 40 CFR 260-262, state, and local requirements, and installation instructions. 3.7.3.5 Disposal Documentation for Hazardous and Regulated Waste Contact the Contracting Officer for the facility RCRA identification number that is to be used on each manifest. Submit a copy of the applicable EPA and or state permit(s), manifest(s), or license(s) for transportation, treatment, storage, and disposal of hazardous and regulated waste by permitted facilities. Hazardous or toxic waste manifests must be reviewed, signed, and approved by the Contracting Officer before the Contractor may ship waste. To obtain specific disposal instructions, coordinate with the Installation Environmental Office. SECTION 01 57 19 Page 24 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.7.4 Releases/Spills of Oil and Hazardous Substances 3.7.4.1 Response and Notifications Exercise due diligence to prevent, contain, and respond to spills of hazardous material, hazardous substances, hazardous waste, sewage, regulated gas, petroleum, lubrication oil, and other substances regulated in accordance with 40 CFR 300. Maintain spill cleanup equipment and materials at the work site. In the event of a spill, take prompt, effective action to stop, contain, curtail, or otherwise limit the amount, duration, and severity of the spill/release. In the event of any releases of oil and hazardous substances, chemicals, or gases; immediately (within 15 minutes) notify the Installation Fire Department, the Installation Command Duty Officer, the Installation Environmental Office, and the Contracting Officer. Submit verbal and written notifications as required by the federal ( 40 CFR 300.125 and 40 CFR 355), state, local regulations and instructions. Provide copies of the written notification and documentation that a verbal notification was made within 20 days. Spill response must be in accordance with 40 CFR 300 and applicable state and local regulations. Contain and clean up these spills without cost to the Government. 3.7.4.2 Clean Up Clean up hazardous and non-hazardous waste spills. Reimburse the Government for costs incurred including sample analysis materials, clothing, equipment, and labor if the Government will initiate its own spill cleanup procedures, for Contractor- responsible spills, when: Spill cleanup procedures have not begun within one hour of spill discovery/occurrence; or, in the Government's judgment, spill cleanup is inadequate and the spill remains a threat to human health or the environment. 3.7.5 Mercury Materials Immediately report to the Environmental Office and the Contracting Officer instances of breakage or mercury spillage. Clean mercury spill area to the satisfaction of the Contracting Officer. Do not recycle a mercury spill cleanup; manage it as a hazardous waste for disposal. 3.7.6 Wastewater Dispose of wastewater as specified below. 3.7.6.1 Treatment Do not allow wastewater from construction activities, such as onsite material processing, concrete curing, foundation and concrete clean-up, water used in concrete trucks, and forms to enter water ways or to be discharged prior to being treated to remove pollutants. Dispose of the construction- related waste water off-Government property in accordance with 40 CFR 403, state, regional, and local laws and regulations. SECTION 01 57 19 Page 25 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.7.6.2 Surface Discharge Surface discharge in accordance with the requirements of the NPDES or state STORMWATER DISCHARGES FROM CONSTRUCTION SITES permit. A sediment control pond is located at a low point near Eagle Talon Drive. It will be used for the this projects. The Contractor is required to treat any 95% storm event on site and attenuate the peak flows to match the pre peak flows as required by the state including the 50 year storm since basin DA 9 drains into a wetland. 3.7.6.3 Land Application Water generated from the flushing of lines after disinfection or disinfection in conjunction with hydrostatic testing must be discharged into the sanitary sewer with prior approval and notification to the Wastewater Treatment Plant's Operator. 3.8 HAZARDOUS MATERIAL MANAGEMENT Include hazardous material control procedures in the Safety Plan, in accordance with Section 01 35 26 GOVERNMENTAL SAFETY REQUIREMENTS. Address procedures and proper handling of hazardous materials, including the appropriate transportation requirements. Do not bring hazardous material onto Government property that does not directly relate to requirements for the performance of this contract. Submit an SDS and estimated quantities to be used for each hazardous material to the Contracting Officer prior to bringing the material on the installation. Typical materials requiring SDS and quantity reporting include, but are not limited to, oil and latex based painting and caulking products, solvents, adhesives, aerosol, and petroleum products. Use hazardous materials in a manner that minimizes the amount of hazardous waste generated. Containers of hazardous materials must have National Fire Protection Association labels or their equivalent. Certify that hazardous materials removed from the site are hazardous materials and do not meet the definition of hazardous waste, in accordance with 40 CFR 261. 3.9 PREVIOUSLY USED EQUIPMENT Clean previously used construction equipment prior to bringing it onto the project site. Equipment must be free from soil residuals, egg deposits from plant pests, noxious weeds, and plant seeds. Consult with the U.S. Department of Agriculture jurisdictional office for additional cleaning requirements. 3.10 MILITARY MUNITIONS In the event military munitions, as defined in 40 CFR 260, are discovered or uncovered, immediately stop work in that area and immediately inform the Contracting Officer. 3.11 PETROLEUM, OIL, LUBRICANT (POL) STORAGE AND FUELING POL products include flammable or combustible liquids, such as gasoline, diesel, lubricating oil, used engine oil, hydraulic oil, mineral oil, and cooking oil. Store POL products and fuel equipment and motor vehicles in a manner that affords the maximum protection against spills into the environment. Manage and store POL products in accordance with EPA 40 CFR 112, and other federal, state, regional, and local laws and regulations. Use secondary containments, dikes, curbs, and other SECTION 01 57 19 Page 26 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% barriers, to prevent POL products from spilling and entering the ground, storm or sewer drains, stormwater ditches or canals, or navigable waters of the United States. Describe in the EPP (see paragraph ENVIRONMENTAL PROTECTION PLAN) how POL tanks and containers must be stored, managed, and inspected and what protections must be provided. Storage of oil, including fuel, on the project site is not allowed. Fuel must be brought to the project site each day that work is performed. 3.11.1 Used Oil Management Manage used oil generated on site in accordance with 40 CFR 279. Determine if any used oil generated while onsite exhibits a characteristic of hazardous waste. Used oil containing 1,000 parts per million of solvents is considered a hazardous waste and disposed of at the Contractor's expense. Used oil mixed with a hazardous waste is also considered a hazardous waste. Dispose in accordance with paragraph HAZARDOUS WASTE DISPOSAL. 3.11.2 Oil Storage Including Fuel Tanks Provide secondary containment and overfill protection for oil storage tanks. A berm used to provide secondary containment must be of sufficient size and strength to contain the contents of the tanks plus 5 inches freeboard for precipitation. Construct the berm to be impervious to oil for 72 hours that no discharge will permeate, drain, infiltrate, or otherwise escape before cleanup occurs. Use drip pans during oil transfer operations; adequate absorbent material must be onsite to clean up any spills and prevent releases to the environment. Cover tanks and drip pans during inclement weather. Provide procedures and equipment to prevent overfilling of tanks. If tanks and containers with an aggregate aboveground capacity greater than 1320 gallons will be used onsite (only containers with a capacity of 55 gallons or greater are counted), provide and implement a SPCC plan meeting the requirements of 40 CFR 112. Do not bring underground storage tanks to the installation for Contractor use during a project. Submit the SPCC plan to the Contracting Officer for approval. Monitor and remove any rainwater that accumulates in open containment dikes or berms. Inspect the accumulated rainwater prior to draining from a containment dike to the environment, to determine there is no oil sheen present. 3.12 INADVERTENT DISCOVERY OF PETROLEUM-CONTAMINATED SOIL OR HAZARDOUS WASTES If petroleum-contaminated soil, or suspected hazardous waste is found during construction that was not identified in the Contract documents, immediately notify the Contracting Officer. Do not disturb this material until authorized by the Contracting Officer. 3.13 PEST MANAGEMENT In order to minimize impacts to existing fauna and flora, coordinate with the Installation Pest Management Coordinator (IPMC) or Project Pesticide Coordinator (PPC), through the Contracting Officer, at the earliest possible time prior to pesticide application. Discuss integrated pest management strategies with the IPMC or PPC and receive concurrence from the IPMCand or PPC through the Contracting Officer prior to the application of any pesticide associated with these specifications. SECTION 01 57 19 Page 27 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Provide Installation Project Office Pest Management personnel the opportunity to be present at meetings concerning treatment measures for pest or disease control and during application of the pesticide. The use and management of pesticides are regulated under 40 CFR 152 - 186. 3.13.1 Application Apply pesticides using a state-certified pesticide applicator in accordance with EPA label restrictions and recommendation. The certified applicator must wear clothing and personal protective equipment as specified on the pesticide label. The Contracting Officer will designate locations for water used in formulating. Do not allow the equipment to overflow. Inspect equipment for leaks, clogging, wear, or damage and repair prior to application of pesticide. 3.13.2 Pesticide Treatment Plan Include and update a pesticide treatment plan, as information becomes available. Include in the plan the sequence of treatment, dates, times, locations, pesticide trade name, EPA registration numbers, authorized uses, chemical composition, formulation, original and applied concentration, application rates of active ingredient (that is, pounds of active ingredient applied), equipment used for application and calibration of equipment. Comply with 40 CFR 152-189, state, regional, and local pest management record-keeping and reporting requirements as well as any additional Installation Project Office specific requirements in conformance with DA AR 200-1 Chapter 5, Pest Management, Section 5-4 "Program requirements" for data required to be reported to the Installation. 3.14 SOUND INTRUSION Make the maximum use of low-noise emission products, as certified by the EPA. Blasting or use of explosives are not permitted without written permission from the Contracting Officer, and then only during the designated times. Keep construction activities under surveillance and control to minimize environment damage by noise. Comply with the State of North Carolina rules. 3.15 POST CONSTRUCTION CLEANUP Clean up areas used for construction in accordance with Contract Clause: "Cleaning Up". Unless otherwise instructed in writing by the Contracting Officer, remove traces of temporary construction facilities such as haul routes, work area, structures, foundations of temporary structures, stockpiles of excess or waste materials, and other vestiges of construction prior to final acceptance of the work. Grade parking area and similar temporarily used areas to conform with surrounding contours. -- End of Section -- SECTION 01 57 19 Page 28 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 31 00 00 EARTHWORK 08/08 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO) AASHTO T 180 (2017) Standard Method of Test for Moisture-Density Relations of Soils Using a 4.54-kg (10-lb) Rammer and a 457-mm (18-in.) Drop AASHTO T 224 (2010) Standard Method of Test for Correction for Coarse Particles in the Soil Compaction Test AMERICAN WATER WORKS ASSOCIATION (AWWA) AWWA C600 (2017) Installation of Ductile-Iron Mains and Their Appurtenances ASTM INTERNATIONAL (ASTM) ASTM C136/C136M (2014) Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates ASTM C33/C33M (2018) Standard Specification for Concrete Aggregates ASTM D1140 (2017) Standard Test Methods for Determining the Amount of Material Finer than 75-µm (No. 200) Sieve in Soils by Washing ASTM D1556/D1556M (2015; E 2016) Standard Test Method for Density and Unit Weight of Soil in Place by Sand-Cone Method ASTM D1557 (2012; E 2015) Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort (56,000 ft-lbf/ft3) (2700 kN-m/m3) ASTM D1883 (2016) Standard Test Method for California Bearing Ratio (CBR) of Laboratory-Compacted Soils ASTM D2167 (2015) Density and Unit Weight of Soil in SECTION 31 00 00 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Place by the Rubber Balloon Method ASTM D2487 (2017) Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System) ASTM D2937 (2017; E 2017; E 2018) Standard Test Method for Density of Soil in Place by the Drive-Cylinder Method ASTM D4318 (2017; E 2018) Standard Test Methods for Liquid Limit, Plastic Limit, and Plasticity Index of Soils ASTM D6938 (2017a) Standard Test Method for In-Place Density and Water Content of Soil and Soil-Aggregate by Nuclear Methods (Shallow Depth) ASTM D698 (2012; E 2014; E 2015) Laboratory Compaction Characteristics of Soil Using Standard Effort (12,400 ft-lbf/cu. ft. (600 kN-m/cu. m.)) U.S. ENVIRONMENTAL PROTECTION AGENCY (EPA) EPA 600/4-79/020 (1983) Methods for Chemical Analysis of Water and Wastes EPA SW-846.3-3 (1999, Third Edition, Update III-A) Test Methods for Evaluating Solid Waste: Physical/Chemical Methods 1.2 DEFINITIONS 1.2.1 Satisfactory Materials Satisfactory materials comprise any materials classified by ASTM D2487 as GW, GP, GM, GP-GM, GW-GM, GC, GP-GC, GM-GC, SW, SP, SM, SW-SM, SC, SW-SC, SP-SM, SP-SC, CL, CL-ML, CH, MH. Satisfactory materials for grading comprise stones less than 8 inches, except for fill material for pavements and railroads which comprise stones less than 3 inches in any dimension. 1.2.2 Unsatisfactory Materials Materials which do not comply with the requirements for satisfactory materials are unsatisfactory. Unsatisfactory materials also include man-made fills; trash; refuse; backfills from previous construction; and material classified as satisfactory which contains root and other organic matter or frozen material. Notify the Contracting Officer when encountering any contaminated materials. 1.2.3 Cohesionless and Cohesive Materials Cohesionless materials include materials classified in ASTM D2487 as GW, GP, SW, and SP. Cohesive materials include materials classified as GC, SC, ML, CL, MH, and CH. Materials classified as GM and SM will be identified as cohesionless only when the fines are nonplastic. Perform SECTION 31 00 00 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% testing, required for classifying materials, in accordance with ASTM D4318, ASTM C136/C136M and ASTM D1140. 1.2.4 Degree of Compaction Degree of compaction required, except as noted in the second sentence, is expressed as a percentage of the maximum density obtained by the test procedure presented in ASTM D1557 abbreviated as a percent of laboratory maximum density. Since ASTM D1557 applies only to soils that have 30 percent or less by weight of their particles retained on the 3/4 inch sieve, express the degree of compaction for material having more than 30 percent by weight of their particles retained on the 3/4 inch sieve as a percentage of the maximum density in accordance with AASHTO T 180 and corrected with AASHTO T 224. To maintain the same percentage of coarse material, use the "remove and replace" procedure as described in NOTE 8 of Paragraph 7.2 in AASHTO T 180. 1.2.5 Topsoil Material suitable for topsoils obtained from offsite areas or excavations is defined as: Natural, friable soil representative of productive, well-drained soils in the area, free of subsoil, stumps, rocks larger than one inch diameter, brush, weeds, toxic substances, and other material detrimental to plant growth. Amend topsoil pH range to obtain a pH of 5.5 to 7. 1.2.6 Hard/Unyielding Materials Hard/Unyielding materials comprise weathered rock, dense consolidated deposits, or conglomerate materials which are not included in the definition of "rock" with stones greater than 3 inch in any dimension or as defined by the pipe manufacturer, whichever is smaller. These materials usually require the use of heavy excavation equipment, ripper teeth, or jack hammers for removal. 1.2.7 Rock Solid homogeneous interlocking crystalline material with firmly cemented, laminated, or foliated masses or conglomerate deposits, neither of which can be removed without systematic drilling and blasting, drilling and the use of expansion jacks or feather wedges, or the use of backhoe-mounted pneumatic hole punchers or rock breakers; also large boulders, buried masonry, or concrete other than pavement exceeding 1/2 cubic yard in volume. Removal of hard material will not be considered rock excavation because of intermittent drilling and blasting that is performed merely to increase production. 1.2.8 Unstable Material Unstable materials are too wet to properly support the utility pipe, conduit, or appurtenant structure. 1.2.9 Select Granular Material 1.2.9.1 General Requirements Select granular material consist of materials classified as GW, GP, SW, or SP, by ASTM D2487 where indicated. The liquid limit of such material must not exceed 35 percent when tested in accordance with ASTM D4318. The SECTION 31 00 00 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% plasticity index must not be greater than 12 percent when tested in accordance with ASTM D4318, and not more than 35 percent by weight may be finer than No. 200 sieve when tested in accordance with ASTM D1140. 1.2.9.2 California Bearing Ratio Values Bearing Ratio: At 0.1 inch penetration, provide a bearing ratio of 5 percent at 95 percent ASTM D1557 maximum density as determined in accordance with ASTM D1883 for a laboratory soaking period of not less than 4 days. Sieve Size Percent Passing by Weight 2-1/2 inches 100 No. 4 40 - 85 No. 10 20 - 80 No. 40 10 - 60 No. 200 5 - 25 1.2.10 Initial Backfill Material Initial backfill consists of select granular material or satisfactory materials free from rocks 3 inches or larger in any dimension or free from rocks of such size as recommended by the pipe manufacturer, whichever is smaller. When the pipe is coated or wrapped for corrosion protection, free the initial backfill material of stones larger than 3 inches in any dimension or as recommended by the pipe manufacturer, whichever is smaller. 1.2.11 Expansive Soils Expansive soils are defined as soils that have a plasticity index equal to or greater than 30 when tested in accordance with ASTM D4318. 1.3 SYSTEM DESCRIPTION Subsurface soil boring logs are shown on the drawings. These data represent the best subsurface information available; however, variations may exist in the subsurface between boring locations. 1.3.1 Classification of Excavation No consideration will be given to the nature of the materials, and all excavation will be designated as unclassified excavation. 1.3.1.1 Common Excavation Include common excavation with the satisfactory removal and disposal of all materials not classified as rock excavation. 1.3.1.2 Rock Excavation Submit notification of encountering rock in the project. Include rock excavation with blasting, excavating, grading, disposing of material SECTION 31 00 00 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% classified as rock, and the satisfactory removal and disposal of boulders 1/2 cubic yard or more in volume; solid rock; rock material that is in ledges, bedded deposits, and unstratified masses, which cannot be removed without systematic drilling and blasting; firmly cemented conglomerate deposits possessing the characteristics of solid rock impossible to remove without systematic drilling and blasting; and hard materials (see Definitions). Include the removal of any concrete or masonry structures, except pavements, exceeding 1/2 cubic yard in volume that may be encountered in the work in this classification. If at any time during excavation, including excavation from borrow areas, the Contractor encounters material that may be classified as rock excavation, uncover such material and notify the Contracting Officer. Do not proceed with the excavation of this material until the Contracting Officer has classified the materials as common excavation or rock excavation and has taken cross sections as required. Failure on the part of the Contractor to uncover such material, notify the Contracting Officer, and allow ample time for classification and cross sectioning of the undisturbed surface of such material will cause the forfeiture of the Contractor's right of claim to any classification or volume of material to be paid for other than that allowed by the Contracting Officer for the areas of work in which such deposits occur. 1.3.2 Dewatering Work Plan Submit procedures for accomplishing dewatering work. 1.4 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-01 Preconstruction Submittals Shoring Dewatering Work Plan SD-03 Product Data Utilization of Excavated Materials Rock Excavation Opening of any Excavation or Borrow Pit SD-06 Test Reports Testing Borrow Site Testing Within 24 hours of conclusion of physical tests, submit 3 copies of test results, including calibration curves and results of calibration tests. SD-07 Certificates SECTION 31 00 00 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Testing PART 2 PRODUCTS 2.1 REQUIREMENTS FOR OFFSITE SOILS Test offsite soils brought in for use as backfill for Total Petroleum Hydrocarbons (TPH), Benzene, Toluene, Ethyl Benzene, and Xylene (BTEX) and full Toxicity Characteristic Leaching Procedure (TCLP) including ignitability, corrosivity and reactivity. Backfill shall contain a maximum of 100 parts per million (ppm) of total petroleum hydrocarbons (TPH) and a maximum of 10 ppm of the sum of Benzene, Toluene, Ethyl Benzene, and Xylene (BTEX) and shall pass the TCPL test. Determine TPH concentrations by using EPA 600/4-79/020 Method 418.1. Determine BTEX concentrations by using EPA SW-846.3-3 Method 5030/8020. Perform TCLP in accordance with EPA SW-846.3-3 Method 1311. Provide Borrow Site Testing for TPH, BTEX and TCLP from a composite sample of material from the borrow site, with at least one test from each borrow site. Do not bring material onsite until tests have been approved by the Contracting Officer. 2.2 BURIED WARNING AND IDENTIFICATION TAPE Provide polyethylene plastic and/or metallic core or metallic-faced, acid- and alkali-resistant, polyethylene plastic warning tape manufactured specifically for warning and identification of buried utility lines. Provide tape on rolls, 3 inches minimum width, color coded as specified below for the intended utility with warning and identification imprinted in bold black letters continuously over the entire tape length. Warning and identification to read, "CAUTION, BURIED (intended service) LINE BELOW" or similar wording. Provide permanent color and printing, unaffected by moisture or soil. Warning Tape Color Codes Red Electric Yellow Gas, Oil; Dangerous Materials Orange Telephone and Other Communications Blue Water Systems Green Sewer Systems White Steam Systems Gray Compressed Air 2.2.1 Warning Tape for Metallic Piping Provide acid and alkali-resistant polyethylene plastic tape conforming to the width, color, and printing requirements specified above, with a minimum thickness of 0.003 inch and a minimum strength of 1500 psi lengthwise, and 1250 psi crosswise, with a maximum 350 percent elongation. SECTION 31 00 00 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.2.2 Detectable Warning Tape for Non-Metallic Piping Provide polyethylene plastic tape conforming to the width, color, and printing requirements specified above, with a minimum thickness of 0.004 inch, and a minimum strength of 1500 psi lengthwise and 1250 psi crosswise. Manufacture tape with integral wires, foil backing, or other means of enabling detection by a metal detector when tape is buried up to 3 feet deep. Encase metallic element of the tape in a protective jacket or provide with other means of corrosion protection. 2.3 DETECTION WIRE FOR NON-METALLIC PIPING Insulate a single strand, solid copper detection wire with a minimum of 12 AWG. 2.4 MATERIAL FOR RIP-RAP Provide Filter fabric and rock conforming to North Carolina DOT for construction indicated. 2.4.1 Rock Provide rock fragments sufficiently durable to ensure permanence in the structure and the environment in which it is to be used. Use rock fragments free from cracks, seams, and other defects that would increase the risk of deterioration from natural causes. Provide fragments sized so that no individual fragment exceeds a weight of 150 pounds and that no more than 10 percent of the mixture, by weight, consists of fragments weighing 2 pounds or less each. Provide rock with a minimum specific gravity of 2.50 . Do not permit the inclusion of more than trace 1 percent quantities of dirt, sand, clay, and rock fines. 2.5 CAPILLARY WATER BARRIER Provide capillary water barrier of clean, poorly graded crushed rock, crushed gravel, or uncrushed gravel placed beneath a building slab with or without a vapor barrier to cut off the capillary flow of pore water to the area immediately below. Conform to ASTM C33/C33M for fine aggregate grading with a maximum of 3 percent by weight passing ASTM D1140, No. 200 sieve, or 1-1/2 inch and no more than 2 percent by weight passing the No. 4 size sieve or coarse aggregate Size 57, 67, or 77. PART 3 EXECUTION 3.1 STRIPPING OF TOPSOIL Where indicated or directed, strip topsoil to a depth of 4 inches. Spread topsoil on areas already graded and prepared for topsoil, or transported and deposited in stockpiles convenient to areas that are to receive application of the topsoil later, or at locations indicated or specified. Keep topsoil separate from other excavated materials, brush, litter, objectionable weeds, roots, stones larger than 2 inches in diameter, and other materials that would interfere with planting and maintenance operations. Stockpile in locations indicated and remove from the site any surplus of topsoil from excavations and gradings. 3.2 GENERAL EXCAVATION Perform excavation of every type of material encountered within the limits SECTION 31 00 00 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% of the project to the lines, grades, and elevations indicated and as specified. Perform the grading in accordance with the typical sections shown and the tolerances specified in paragraph FINISHING. Transport satisfactory excavated materials and place in fill or embankment within the limits of the work. Excavate unsatisfactory materials encountered within the limits of the work below grade and replace with satisfactory materials as directed. Include such excavated material and the satisfactory material ordered as replacement in excavation. Dispose surplus satisfactory excavated material not required for fill or embankment in areas approved for surplus material storage or designated waste areas. Dispose unsatisfactory excavated material in designated waste or spoil areas. During construction, perform excavation and fill in a manner and sequence that will provide proper drainage at all times. Excavate material required for fill or embankment in excess of that produced by excavation within the grading limits from the borrow areas indicated or from other approved areas selected by the Contractor as specified. 3.2.1 Ditches, Gutters, and Channel Changes Finish excavation of ditches, gutters, and channel changes by cutting accurately to the cross sections, grades, and elevations shown on Drawings. Do not excavate ditches and gutters below grades shown. Backfill the excessive open ditch or gutter excavation with satisfactory, thoroughly compacted, material or with suitable stone or cobble to grades shown. Dispose excavated material as shown or as directed, except in no case allow material be deposited a maximum 4 feet from edge of a ditch. Maintain excavations free from detrimental quantities of leaves, brush, sticks, trash, and other debris until final acceptance of the work. 3.2.2 Drainage Structures Make excavations to the lines, grades, and elevations shown, or as directed. Provide trenches and foundation pits of sufficient size to permit the placement and removal of forms for the full length and width of structure footings and foundations as shown. Clean rock or other hard foundation material of loose debris and cut to a firm, level, stepped, or serrated surface. Remove loose disintegrated rock and thin strata. Do not disturb the bottom of the excavation when concrete or masonry is to be placed in an excavated area. Do not excavate to the final grade level until just before the concrete or masonry is to be placed. 3.2.3 Drainage Provide for the collection and disposal of surface and subsurface water encountered during construction. Completely drain construction site during periods of construction to keep soil materials sufficiently dry. Construct storm drainage features (ponds/basins) at the earliest stages of site development, and throughout construction grade the construction area to provide positive surface water runoff away from the construction activity and or provide temporary ditches, swales, and other drainage features and equipment as required to maintain dry soils. When unsuitable working platforms for equipment operation and unsuitable soil support for subsequent construction features develop, remove unsuitable material and provide new soil material as specified herein. It is the responsibility of the Contractor to assess the soil and ground water conditions presented by the plans and specifications and to employ necessary measures to permit construction to proceed. SECTION 31 00 00 Page 8 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.2.4 Dewatering Control groundwater flowing toward or into excavations to prevent sloughing of excavation slopes and walls, boils, uplift and heave in the excavation and to eliminate interference with orderly progress of construction. Do not permit French drains, sumps, ditches or trenches within 3 feet of the foundation of any structure, except with specific written approval, and after specific contractual provisions for restoration of the foundation area have been made. Take control measures by the time the excavation reaches the water level in order to maintain the integrity of the in situ material. While the excavation is open, maintain the water level continuously, at least 3 feet below the working level. 3.2.5 Trench Excavation Requirements Excavate the trench as recommended by the manufacturer of the pipe to be installed. Slope trench walls below the top of the pipe, or make vertical, and of such width as recommended in the manufacturer's printed installation manual. Provide vertical trench walls where no manufacturer's printed installation manual is available. Shore trench walls more than 4 feet high, cut back to a stable slope, or provide with equivalent means of protection for employees who may be exposed to moving ground or cave in. Shore vertical trench walls more than 4 feet high. Excavate trench walls which are cut back to at least the angle of repose of the soil. Give special attention to slopes which may be adversely affected by weather or moisture content. Do not exceed the trench width below the pipe top of 24 inches plus pipe outside diameter (O.D.) for pipes of less than 24 inches inside diameter, and do not exceed 36 inches plus pipe outside diameter for sizes larger than 24 inches inside diameter. Where recommended trench widths are exceeded, provide redesign, stronger pipe, or special installation procedures by the Contractor. The Contractor is responsible for the cost of redesign, stronger pipe, or special installation procedures without any additional cost to the Government. 3.2.5.1 Bottom Preparation Grade the bottoms of trenches accurately to provide uniform bearing and support for the bottom quadrant of each section of the pipe. Excavate bell holes to the necessary size at each joint or coupling to eliminate point bearing. Remove stones of 3 inch or greater in any dimension, or as recommended by the pipe manufacturer, whichever is smaller, to avoid point bearing. 3.2.5.2 Removal of Unyielding Material Where unyielding material is encountered in the bottom of the trench, remove such material 4 inch below the required grade and replaced with suitable materials as provided in paragraph BACKFILLING AND COMPACTION. 3.2.5.3 Removal of Unstable Material Where unstable material is encountered in the bottom of the trench, remove such material to the depth directed and replace it to the proper grade with select granular material as provided in paragraph BACKFILLING AND COMPACTION. When removal of unstable material is required due to the Contractor's fault or neglect in performing the work, the Contractor is responsible for excavating the resulting material and replacing it without SECTION 31 00 00 Page 9 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% additional cost to the Government. 3.2.5.4 Excavation for Appurtenances Provide excavation for manholes, catch-basins, inlets, or similar structures of sufficient size to permit the placement and removal of forms for the full length and width of structure footings and foundations as shown. Clean rock or loose debris and cut to a firm surface either level, stepped, or serrated, as shown or as directed. Remove loose disintegrated rock and thin strata. Specify removal of unstable material. When concrete or masonry is to be placed in an excavated area, take special care not to disturb the bottom of the excavation. Do not excavate to the final grade level until just before the concrete or masonry is to be placed. 3.2.6 Underground Utilities The Contractor is responsible for movement of construction machinery and equipment over pipes and utilities during construction. Perform work adjacent to non-Government utilities as indicated in accordance with procedures outlined by utility company. Excavation made with power-driven equipment is not permitted within 2 feet of known Government-owned utility or subsurface construction. For work immediately adjacent to or for excavations exposing a utility or other buried obstruction, excavate by hand. Start hand excavation on each side of the indicated obstruction and continue until the obstruction is uncovered or until clearance for the new grade is assured. Support uncovered lines or other existing work affected by the contract excavation until approval for backfill is granted by the Contracting Officer. Report damage to utility lines or subsurface construction immediately to the Contracting Officer. 3.2.7 Structural Excavation Ensure that footing subgrades have been inspected and approved by the Contracting Officer prior to concrete placement. 3.3 SELECTION OF BORROW MATERIAL Select borrow material to meet the requirements and conditions of the particular fill or embankment for which it is to be used. Unless otherwise provided in the contract, the Contractor is responsible for obtaining the right to procure material, pay royalties and other charges involved, and bear the expense of developing the sources, including rights-of-way for hauling from the owners. Borrow material from approved sources on Government-controlled land may be obtained without payment of royalties. Unless specifically provided, do not obtain borrow within the limits of the project site without prior written approval. Consider necessary clearing, grubbing, and satisfactory drainage of borrow pits and the disposal of debris thereon related operations to the borrow excavation. 3.4 OPENING AND DRAINAGE OF EXCAVATION AND BORROW PITS Notify the Contracting Officer sufficiently in advance of the opening of any excavation or borrow pit or borrow areas to permit elevations and measurements of the undisturbed ground surface to be taken. Except as otherwise permitted, excavate borrow pits and other excavation areas providing adequate drainage. Transport overburden and other spoil material to designated spoil areas or otherwise dispose of as directed. Provide neatly trimmed and drained borrow pits after the excavation is SECTION 31 00 00 Page 10 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% completed. Ensure that excavation of any area, operation of borrow pits, or dumping of spoil material results in minimum detrimental effects on natural environmental conditions. 3.5 SHORING 3.5.1 General Requirements Submit a Shoring and Sheeting plan for approval 15 days prior to starting work. Submit drawings and calculations, certified by a registered professional engineer, describing the methods for shoring and sheeting of excavations. Finish shoring, including sheet piling, and install as necessary to protect workmen, banks, adjacent paving, structures, and utilities. Remove shoring, bracing, and sheeting as excavations are backfilled, in a manner to prevent caving. 3.5.2 Geotechnical Engineer Hire a Professional Geotechnical Engineer to provide inspection of excavations and soil/groundwater conditions throughout construction. The Geotechnical Engineer is responsible for performing pre-construction and periodic site visits throughout construction to assess site conditions. The Geotechnical Engineer is responsible for updating the excavation, sheeting and dewatering plans as construction progresses to reflect changing conditions and submit an updated plan if necessary. Submit a monthly written report, informing the Contractor and Contracting Officer of the status of the plan and an accounting of the Contractor's adherence to the plan addressing any present or potential problems. The Contracting Officer is responsible for arranging meetings with the Geotechnical Engineer at any time throughout the contract duration. 3.6 GRADING AREAS Where indicated, divide work into grading areas within which satisfactory excavated material will be placed in embankments, fills, and required backfills. Do not haul satisfactory material excavated in one grading area to another grading area except when so directed in writing. Place and grade stockpiles of satisfactory and unsatisfactory and wasted materials as specified. Keep stockpiles in a neat and well drained condition, giving due consideration to drainage at all times. Clear, grub, and seal by rubber-tired equipment, the ground surface at stockpile locations; separately stockpile excavated satisfactory and unsatisfactory materials. Protect stockpiles of satisfactory materials from contamination which may destroy the quality and fitness of the stockpiled material. If the Contractor fails to protect the stockpiles, and any material becomes unsatisfactory, remove and replace such material with satisfactory material from approved sources. 3.7 FINAL GRADE OF SURFACES TO SUPPORT CONCRETE Do not excavate to final grade until just before concrete is to be placed. Only use excavation methods that will leave the foundation rock in a solid and unshattered condition. Roughen the level surfaces, and cut the sloped surfaces, as indicated, into rough steps or benches to provide a satisfactory bond. Protect shales from slaking and all surfaces from erosion resulting from ponding or water flow. SECTION 31 00 00 Page 11 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.8 GROUND SURFACE PREPARATION 3.8.1 General Requirements Remove and replace unsatisfactory material with satisfactory materials, as directed by the Contracting Officer, in surfaces to receive fill or in excavated areas. Scarify the surface to a depth of 6 inches before the fill is started. Plow, step, bench, or break up sloped surfaces steeper than 1 vertical to 4 horizontal so that the fill material will bond with the existing material. When subgrades are less than the specified density, break up the ground surface to a minimum depth of 6 inches, pulverizing, and compacting to the specified density. When the subgrade is part fill and part excavation or natural ground, scarify the excavated or natural ground portion to a depth of 12 inches and compact it as specified for the adjacent fill. 3.8.2 Frozen Material Do not place material on surfaces that are muddy, frozen, or contain frost. Finish compaction by sheepsfoot rollers, pneumatic-tired rollers, steel-wheeled rollers, or other approved equipment well suited to the soil being compacted. Moisten material as necessary to provide the moisture content that will readily facilitate obtaining the specified compaction with the equipment used. 3.9 UTILIZATION OF EXCAVATED MATERIALS Dispose unsatisfactory materials removing from excavations into designated waste disposal or spoil areas. Use satisfactory material removed from excavations, insofar as practicable, in the construction of fills, embankments, subgrades, shoulders, bedding (as backfill), and for similar purposes. Submit procedure and location for disposal of unused satisfactory material. Submit proposed source of borrow material. Do not waste any satisfactory excavated material without specific written authorization. Dispose of satisfactory material, authorized to be wasted, in designated areas approved for surplus material storage or designated waste areas as directed. Clear and grub newly designated waste areas on Government-controlled land before disposal of waste material thereon. Stockpile and use coarse rock from excavations for constructing slopes or embankments adjacent to streams, or sides and bottoms of channels and for protecting against erosion. Do not dispose excavated material to obstruct the flow of any stream, endanger a partly finished structure, impair the efficiency or appearance of any structure, or be detrimental to the completed work in any way. 3.10 BURIED TAPE AND DETECTION WIRE 3.10.1 Buried Warning and Identification Tape Provide buried utility lines with utility identification tape. Bury tape 12 inches below finished grade; under pavements and slabs, bury tape 6 inches below top of subgrade. 3.10.2 Buried Detection Wire Bury detection wire directly above non-metallic piping at a distance not to exceed 12 inches above the top of pipe. Extend the wire continuously and unbroken, from manhole to manhole. Terminate the ends of the wire inside the manholes at each end of the pipe, with a minimum of 3 feet of SECTION 31 00 00 Page 12 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% wire, coiled, remaining accessible in each manhole. Furnish insulated wire over it's entire length. Install wires at manholes between the top of the corbel and the frame, and extend up through the chimney seal between the frame and the chimney seal. For force mains, terminate the wire in the valve pit at the pump station end of the pipe. 3.11 BACKFILLING AND COMPACTION Place backfill adjacent to any and all types of structures, in successive horizontal layers of loose materia not more than 8 inches in depth. Compact to at least 90 percent laboratory maximum density for cohesive materials or 95 percent laboratory maximum density for cohesionless materials, to prevent wedging action or eccentric loading upon or against the structure. Backfill material must be within the range of -2 to +2 percent of optimum moisture content at the time of compaction. Prepare ground surface on which backfill is to be placed and provide compaction requirements for backfill materials in conformance with the applicable portions of paragraphs GROUND SURFACE PREPARATION. Finish compaction by sheepsfoot rollers, pneumatic-tired rollers, steel-wheeled rollers, vibratory compactors, or other approved equipment. 3.11.1 Trench Backfill Backfill trenches to the grade shown. Backfill the trench to 2 feet above the top of pipe prior to performing the required pressure tests. Leave the joints and couplings uncovered during the pressure test. 3.11.1.1 Replacement of Unyielding Material Replace unyielding material removed from the bottom of the trench with select granular material or initial backfill material. 3.11.1.2 Replacement of Unstable Material Replace unstable material removed from the bottom of the trench or excavation with select granular material placed in layers not exceeding 6 inches loose thickness. 3.11.1.3 Bedding and Initial Backfill Provide bedding of the type and thickness shown. Place initial backfill material and compact it with approved tampers to a height of at least one foot above the utility pipe or conduit. Bring up the backfill evenly on both sides of the pipe for the full length of the pipe. Take care to ensure thorough compaction of the fill under the haunches of the pipe. Except as specified otherwise in the individual piping section, provide bedding for buried piping in accordance with AWWA C600, Type 4, except as specified herein. Compact backfill to top of pipe to 95 percent of ASTM D698 maximum density. Provide plastic piping with bedding to spring line of pipe. Provide materials as follows: 3.11.1.3.1 Class I Angular, 0.25 to 1.5 inch, graded stone, including a number of fill materials that have regional significance such as coral, slag, cinders, crushed stone, and crushed shells. SECTION 31 00 00 Page 13 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.11.1.3.2 Class II Coarse sands and gravels with maximum particle size of 1.5 inch, including various graded sands and gravels containing small percentages of fines, generally granular and noncohesive, either wet or dry. Soil Types GW, GP, SW, and SP are included in this class as specified in ASTM D2487. 3.11.1.3.3 Sand Clean, coarse-grained sand classified as SW or SP by ASTM D2487 for bedding and backfill. 3.11.1.3.4 Gravel and Crushed Stone Clean, coarsely graded natural gravel, crushed stone or a combination thereof identified as GW or GP in accordance with ASTM D2487 for bedding and backfill. Do not exceed maximum particle size of 3 inches. 3.11.1.4 Final Backfill Fill the remainder of the trench, except for special materials for roadways, railroads and airfields, with satisfactory material. Place backfill material and compact as follows: 3.11.1.4.1 Roadways Place backfill up to the required elevation as specified. Do not permit water flooding or jetting methods of compaction. 3.11.1.4.2 Sidewalks, Turfed or Seeded Areas and Miscellaneous Areas Deposit backfill in layers of a maximum of 12 inches loose thickness, and compact it to 85 percent maximum density for cohesive soils and 90 percent maximum density for cohesionless soils. Apply this requirement to all other areas not specifically designated above. 3.11.2 Backfill for Appurtenances After the manhole, catchbasin, inlet, or similar structure has been constructed, place backfill in such a manner that the structure is not be damaged by the shock of falling earth. Deposit the backfill material, compact it as specified for final backfill, and bring up the backfill evenly on all sides of the structure to prevent eccentric loading and excessive stress. 3.12 SPECIAL REQUIREMENTS Special requirements for both excavation and backfill relating to the specific utilities are as follows: 3.12.1 Gas Distribution Excavate trenches to a depth that will provide a minimum 18 inches of cover in rock excavation and a minimum 24 inch of cover in other excavation. 3.12.2 Water Lines Excavate trenches to a depth that provides a minimum cover of 3 feet from SECTION 31 00 00 Page 14 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% the existing ground surface, or from the indicated finished grade, whichever is lower, to the top of the pipe. 3.12.3 Heat Distribution System Free initial backfill material of stones larger than 1/4 inch in any dimension. 3.12.4 Electrical Distribution System Provide a minimum cover of 24 inches from the finished grade to direct burial cable and conduit or duct line, unless otherwise indicated. 3.12.5 Rip-Rap Construction Construct rip-rap on filter fabric in the areas indicated. Trim and dress indicated areas to conform to cross sections, lines and grades shown within a tolerance of 0.1 foot. 3.12.5.1 Stone Placement Place rock for rip-rap on prepared bedding material to produce a well graded mass with the minimum practicable percentage of voids in conformance with lines and grades indicated. Distribute larger rock fragments, with dimensions extending the full depth of the rip-rap throughout the entire mass and eliminate "pockets" of small rock fragments. Rearrange individual pieces by mechanical equipment or by hand as necessary to obtain the distribution of fragment sizes specified above. 3.13 EMBANKMENTS 3.13.1 Earth Embankments Construct earth embankments from satisfactory materials free of organic or frozen material and rocks with any dimension greater than 3 inches. Place the material in successive horizontal layers of loose material not more than 8 inches in depth. Spread each layer uniformly on a soil surface that has been moistened or aerated as necessary, and scarified or otherwise broken up so that the fill will bond with the surface on which it is placed. After spreading, plow, disk, or otherwise break up each layer; moisten or aerate as necessary; thoroughly mix; and compact to at least 90 percent laboratory maximum density for cohesive materials or 95 percent laboratory maximum density for cohesionless materials. Backfill material must be within the range of -2 to +2 percent of optimum moisture content at the time of compaction. Compaction requirements for the upper portion of earth embankments forming subgrade for pavements are identical with those requirements specified in paragraph SUBGRADE PREPARATION. Finish compaction by sheepsfoot rollers, pneumatic-tired rollers, steel-wheeled rollers, vibratory compactors, or other approved equipment. 3.14 SUBGRADE PREPARATION 3.14.1 Proof Rolling Finish proof rolling on an exposed subgrade free of surface water (wet conditions resulting from rainfall) which would promote degradation of an SECTION 31 00 00 Page 15 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% otherwise acceptable subgrade. After stripping, proof roll the existing subgrade with six passes of a dump truck loaded with 4 cubic yards of soil or 15 ton, pneumatic-tired roller. Operate the roller or truck in a systematic manner to ensure the number of passes over all areas, and at speeds between 2-1/2 to 3-1/2 mph. When proof rolling, provide one-half of the passes made with the roller in a direction perpendicular to the other passes. Notify the Contracting Officer a minimum of 3 days prior to proof rolling. Perform proof rolling in the presence of the Contracting Officer. Undercut rutting or pumping of material as directed by the Contracting Officer to a depth of 12 inches and replace with fill and backfill or select material. 3.14.2 Construction Shape subgrade to line, grade, and cross section, and compact as specified. Include plowing, disking, and any moistening or aerating required to obtain specified compaction for this operation. Remove soft or otherwise unsatisfactory material and replace with satisfactory excavated material or other approved material as directed. Excavate rock encountered in the cut section to a depth of 6 inches below finished grade for the subgrade. Bring up low areas resulting from removal of unsatisfactory material or excavation of rock to required grade with satisfactory materials, and shape the entire subgrade to line, grade, and cross section and compact as specified. Do not vary the elevation of the finish subgrade more than 0.05 foot from the established grade and cross section. 3.14.3 Compaction Finish compaction by sheepsfoot rollers, pneumatic-tired rollers, steel-wheeled rollers, vibratory compactors, or other approved equipment. Except for paved areas, compact each layer of the embankment to at least 90 percent of laboratory maximum density. 3.14.3.1 Subgrade for Pavements Compact subgrade for pavements to at least 92 percentage laboratory maximum density for the depth below the surface of the pavement shown. When more than one soil classification is present in the subgrade, thoroughly blend, reshape, and compact the top 4 inch of subgrade. 3.15 FINISHING Finish the surface of excavations, embankments, and subgrades to a smooth and compact surface in accordance with the lines, grades, and cross sections or elevations shown. Provide the degree of finish for graded areas within 0.1 foot of the grades and elevations indicated except that the degree of finish for subgrades specified in paragraph SUBGRADE PREPARATION. Finish gutters and ditches in a manner that will result in effective drainage. Finish the surface of areas to be turfed from settlement or washing to a smoothness suitable for the application of turfing materials. Repair graded, topsoiled, or backfilled areas prior to acceptance of the work, and re-established grades to the required elevations and slopes. 3.15.1 Subgrade and Embankments During construction, keep embankments and excavations shaped and drained. Maintain ditches and drains along subgrade to drain effectively at all SECTION 31 00 00 Page 16 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% times. Do not disturb the finished subgrade by traffic or other operation. Protect and maintain the finished subgrade in a satisfactory condition until ballast, subbase, base, or pavement is placed. Do not permit the storage or stockpiling of materials on the finished subgrade. Do not lay subbase, base course, ballast, or pavement until the subgrade has been checked and approved, and in no case place subbase, base, surfacing, pavement, or ballast on a muddy, spongy, or frozen subgrade. 3.15.2 Capillary Water Barrier Place a capillary water barrier under concrete floor and area-way slabs grade directly on the subgrade and compact with a minimum of two passes of a hand-operated plate-type vibratory compactor. 3.15.3 Grading Around Structures Construct areas within 5 feet outside of each building and structure line true-to-grade, shape to drain, and maintain free of trash and debris until final inspection has been completed and the work has been accepted. 3.16 PLACING TOPSOIL On areas to receive topsoil, prepare the compacted subgrade soil to a 2 inches depth for bonding of topsoil with subsoil. Spread topsoil evenly to a thickness of 6 inch and grade to the elevations and slopes shown. Do not spread topsoil when frozen or excessively wet or dry. Obtain material required for topsoil in excess of that produced by excavation within the grading limits from offsite areas. 3.17 TESTING Perform testing by a Corps validated commercial testing laboratory or the Contractor's validated testing facility. Submit qualifications of the Corps validated commercial testing laboratory or the Contractor's validated testing facilities. If the Contractor elects to establish testing facilities, do not permit work requiring testing until the Contractor's facilities have been inspected, Corps validated and approved by the Contracting Officer. a. Determine field in-place density in accordance with ASTM D1556/D1556M ASTM D2167 ASTM D6938. When ASTM D6938 is used, check the calibration curves and adjust using only the sand cone method as described in ASTM D1556/D1556M. ASTM D6938 results in a wet unit weight of soil in determining the moisture content of the soil when using this method. b. Check the calibration curves furnished with the moisture gauges along with density calibration checks as described in ASTM D6938; check the calibration of both the density and moisture gauges at the beginning of a job on each different type of material encountered and at intervals as directed by the Contracting Officer. ASTM D2937, use the Drive Cylinder Method only for soft, fine-grained, cohesive soils. When test results indicate, as determined by the Contracting Officer, that compaction is not as specified, remove the material, replace and recompact to meet specification requirements. c. Perform tests on recompacted areas to determine conformance with specification requirements. Appoint a registered professional civil engineer to certify inspections and test results. These certifications shall state that the tests and observations were SECTION 31 00 00 Page 17 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% performed by or under the direct supervision of the engineer and that the results are representative of the materials or conditions being certified by the tests. The following number of tests, if performed at the appropriate time, will be the minimum acceptable for each type operation. 3.17.1 Fill and Backfill Material Gradation One test per 2500 cubic yards stockpiled or in-place source material. Determine gradation of fill and backfill material in accordance with ASTM C136/C136M ASTM D1140. 3.17.2 In-Place Densities a. One test per 2500 square feet, or fraction thereof, of each lift of fill or backfill areas compacted by other than hand-operated machines. b. One test per 2500 square feet, or fraction thereof, of each lift of fill or backfill areas compacted by hand-operated machines. c. One test per 100 linear feet, or fraction thereof, of each lift of embankment or backfill for roads. 3.17.3 Moisture Contents In the stockpile, excavation, or borrow areas, perform a minimum of two tests per day per type of material or source of material being placed during stable weather conditions. During unstable weather, perform tests as dictated by local conditions and approved by the Contracting Officer. 3.17.4 Optimum Moisture and Laboratory Maximum Density Perform tests for each type material or source of material including borrow material to determine the optimum moisture and laboratory maximum density values. One representative test per 2500 cubic yards of fill and backfill, or when any change in material occurs which may affect the optimum moisture content or laboratory maximum density. 3.17.5 Tolerance Tests for Subgrades Perform continuous checks on the degree of finish specified in paragraph SUBGRADE PREPARATION during construction of the subgrades. 3.17.6 Displacement of Sewers After other required tests have been performed and the trench backfill compacted to the finished grade surface, inspect the pipe to determine whether significant displacement has occurred. Conduct this inspection in the presence of the Contracting Officer. Inspect pipe sizes larger than 36 inches, while inspecting smaller diameter pipe by shining a light or laser between manholes or manhole locations, or by the use of television cameras passed through the pipe. If, in the judgment of the Contracting Officer, the interior of the pipe shows poor alignment or any other defects that would cause improper functioning of the system, replace or repair the defects as directed at no additional cost to the Government. 3.18 DISPOSITION OF SURPLUS MATERIAL Remove surplus material or other soil material not required or suitable SECTION 31 00 00 Page 18 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% for filling or backfilling, and brush, refuse, stumps, roots, and timber. -- End of Section -- SECTION 31 00 00 Page 19 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 31 05 22 GEOTEXTILES USED AS FILTERS 08/08 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. ASTM INTERNATIONAL (ASTM) ASTM D123 (2015b; R 2017) Standard Terminology Relating to Textiles ASTM D4354 (2012) Sampling of Geosynthetics for Testing ASTM D4355/D4355M (2014) Deterioration of Geotextiles from Exposure to Light, Moisture and Heat in a Xenon-Arc Type Apparatus ASTM D4491/D4491M (2015) Standard Test Methods for Water Permeability of Geotextiles by Permittivity ASTM D4533/D4533M (2015) Standard Test Method for Trapezoid Tearing Strength of Geotextiles ASTM D4632/D4632M (2015a) Grab Breaking Load and Elongation of Geotextiles ASTM D4751 (2016) Standard Test Method for Determining Apparent Opening Size of a Geotextile ASTM D4833/D4833M (2007; E 2013; R 2013) Index Puncture Resistance of Geotextiles, Geomembranes, and Related Products ASTM D4873/D4873M (2017) Standard Guide for Identification, Storage, and Handling of Geosynthetic Rolls and Samples ASTM D4884/D4884M (2014a) Strength of Sewn or Thermally Bonded Seams of Geotextiles U.S. ARMY CORPS OF ENGINEERS (USACE) EM 1110-2-1601 (1991; 1994 Change 1) Engineering and Design -- Hydraulic Design of Flood Control Channels SECTION 31 05 22 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.2 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-06 Test Reports Site Verification SD-07 Certificates Needle Punched Geotextile 1.3 DELIVERY, STORAGE, AND HANDLING Deliver only approved geotextile rolls to the project site. All geotextile shall be labeled, shipped, stored, and handled in accordance with ASTM D4873/D4873M. No hooks, tongs, or other sharp instruments shall be used for handling geotextile. PART 2 PRODUCTS 2.1 MATERIALS 2.1.1 General Provide geotextile that is a non-woven pervious sheet of plastic yarn as defined by ASTM D123 matching or exceeding the minimum average roll values listed in TABLE 1. Strength values indicated in the table are for the weaker principal direction. TABLE 1 MINIMUM PHYSICAL REQUIREMENTS FOR DRAINAGE GEOTEXTILE PROPERTY UNITS ACCEPTABLE VALUES TEST METHOD GRAB STRENGTH lb 200 ASTM D4632/D4632M SEAM STRENGTH lb 160 ASTM D4632/D4632M PUNCTURE lb 125 ASTM D4833/D4833M TRAPEZOID TEAR lb 75 ASTM D4533/D4533M PERMEABILITY cm/sec .004 ASTM D4491/D4491M APPARENT OPENING SIZE U.S. SIEVE 80 ASTM D4751 ULTRAVIOLET DEGRADATION Percent 50 at 500 Hrs ASTM D4355/D4355M SECTION 31 05 22 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.1.2 Geotextile Fiber Fibers used in the manufacturing of the geotextile shall consist of a long-chain synthetic polymer composed of at least 85 percent by weight of polyolefins, polyesters, or polyamides. Add stabilizers and/or inhibitors to the base polymer, if necessary to make the filaments resistant to deterioration caused by ultraviolet light and heat exposure. Reclaimed or recycled fibers or polymer shall not be added to the formulation. Geotextile shall be formed into a network such that the filaments or yarns retain dimensional stability relative to each other, including the edges. Finish the edges of the geotextile to prevent the outer fiber from pulling away from the geotextile. 2.1.3 Seams Sew the seams of the geotextile with thread of a material meeting the chemical requirements given above for geotextile yarn or bond the seams by cementing or by heat. Test seams in accordance with method ASTM D4884/D4884M. The strength of the seam shall be not less than 90 percent of the required grab tensile strength of the unaged geotextile in any principal direction. 2.1.4 Securing Pins Secure the geotextile to the embankment or foundation soil by pins to prevent movement prior to placement of revetment materials. Other appropriate means to prevent movement such as staples, sand bags, and stone could also be used. Insert securing pins through both strips of overlapped geotextile along the line passing through midpoints of the overlap. Remove securing pins as placement of revetment materials are placed to prevent tearing of geotextile or enlarging holes. Maximum spacing between securing pins depends on the steepness of the embankment slope. The maximum pins spacing shall be equal to or less than the values listed in TABLE 2. When windy conditions prevail at the construction site, increase the number of pins upon the demand of the Contracting Officer. Anchor terminal ends of the geotextile with key trench or apron at crest, toe of the slope and upstream and downstream limits of installation. TABLE 2 MAXIMUM SPACING FOR SECURING PINS EMBANKMENT SPACING, feet STEEPER THAN 1V ON 3H 2 1V ON 3H TO 1V ON 4H 3 FLATTER THAN 1V ON 4H 5 2.2 INSPECTIONS, VERIFICATIONS, AND TESTING 2.2.1 Manufacturing and Sampling Geotextiles and factory seams shall meet the requirements specified in TABLE 1. SECTION 31 05 22 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.2.1.1 Conformance Testing Perform conformance testing in accordance with the manufacturers approved quality control manual. Submit manufacturer's quality control conformance test results. 2.2.1.2 Factory Sampling Randomly sample geotextiles in accordance with ASTM D4354 (Procedure Method A). Sample factory seams at the frequency specified in ASTM D4884/D4884M. Provide all samples from the same production lot as will be supplied for the contract, of the full manufactured width of the geotextile by at least 10 feet long, except that samples for seam strength may be a full width sample folded over and the edges stitched for a length of at least 5 feet. Samples submitted for testing shall be identified by manufacturers lot designation. 2.2.1.3 Needle Punched Geotextile For needle punched geotextile, provide manufacturer certification that the geotextile has been inspected using permanent on-line metal detectors and does not contain any needles. 2.2.2 Site Verification and Testing Collect samples at approved locations upon delivery to the site at the request of the Contracting Officer. Test samples to verify that the geotextile meets the requirements specified in TABLE 1. Identify samples by manufacturers name, type of geotextile, lot number, roll number, and machine direction. Perform testing at an approved laboratory. Submit test results from the lot under review for approval prior to deployment of that lot of geotextile. Rolls which are sampled shall be immediately rewrapped in their protective covering. PART 3 EXECUTION 3.1 SURFACE PREPARATION Prepare surface, on which the geotextile will be placed, to a relatively smooth surface condition in accordance with the applicable portion of this specification and shall be free from obstruction, debris, depressions, erosion feature, or vegetation. Remove any irregularities so as to ensure continuous, intimate contact of the geotextile with all the surface. Any loose material, soft or low density pockets of material, shall be removed; erosion features such as rills, gullies etc. shall be graded out of the surface before geotextile placement. 3.2 INSTALLATION OF THE GEOTEXTILE 3.2.1 General Place the geotextile in the manner and at the locations shown. At the time of installation, reject the geotextile if it has defects, rips, holes, flaws, deterioration or damage incurred during manufacture, transportation or storage. 3.2.2 Placement Place the geotextile smooth and free of tension, stress, folds, wrinkles, SECTION 31 05 22 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% or creases. Place the strips to provide a minimum width of 12 inches of overlap for each joint. Adjust the actual length of the geotextile used based on initial installation experience. Temporary pinning of the geotextile to help hold it in place until the bedding layer is placed will be allowed. Remove the temporary pins as the granular material is placed to relieve high tensile stress which may occur during placement of material on the geotextile. Design protection of riprap in compliance with EM 1110-2-1601. Perform trimming in such a manner that the geotextile is not damaged in any way. 3.3 PROTECTION Protect the geotextile at all times during construction from contamination by surface runoff; remove any geotextile so contaminated and replaced with uncontaminated geotextile. Replace any geotextile damaged during its installation or during placement of granular filter materials at no cost to the Government. Schedule the work so that the covering of the geotextile with a layer of the specified material is accomplished within 7 calendar days after placement of the geotextile. Failure to comply shall require replacement of geotextile. Protect the geotextile from damage prior to and during the placement of riprap or other materials. Before placement of riprap or other materials, demonstrate that the placement technique will not cause damage to the geotextile. In no case shall any type of equipment be allowed on the unprotected geotextile. 3.4 PLACEMENT OF CUSHIONING MATERIAL Perform placing of cushioning material in a manner to ensure intimate contact of the geotextile with the prepared surface and with the cushioning material. The placement shall also be performed in a manner that will not damage the geotextile including tear, puncture, or abrasion. On sloping surfaces place the cushioning material from the bottom of the slopes upward. During placement, the height of the drop of riprap material shall not be greater than 12 inches. Uncover any geotextile damaged beneath the cushioning material, as necessary, and replaced at no cost to the Government. 3.5 OVERLAPPING AND SEAMING 3.5.1 Overlapping The overlap of geotextile rolls shall be 12 inches. Appropriate measures will be taken to ensure required overlap exists after cushion placement. 3.5.2 Sewn Seams High strength thread should be used so that seam test conforms to ASTM D4884/D4884M. The thread shall meet the chemical, ultraviolet, and physical requirements of the geotextile, and the color shall be different from that of the geotextile. The seam strength shall be equal to the strength required for the geotextile in the direction across the seam. Overlapping J-type seams are preferable over prayer-type seams as the overlapping geotextile reduces the chance of openings to occur at the seam. Use double sewing, specially for field seams, to provide a safety factor against undetected missed stitches. 3.6 FIELD TESTING Field test geotextile in tension. SECTION 31 05 22 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% -- End of Section -- SECTION 31 05 22 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 31 11 00 CLEARING AND GRUBBING 08/08 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. U.S. DEPARTMENT OF DEFENSE (DOD) DODI 4150.07 (2008; Change 1-2017) DOD Pest Management Program 1.2 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-01 Preconstruction Submittals Herbicide Application Plan SD-03 Product Data Nonsaleable Materials Herbicides SD-04 Samples Tree Wound Paint 1.3 QUALITY CONTROL 1.3.1 Regulatory Requirements Comply with DODI 4150.07 for requirements on Contractor's licensing, certification, and record keeping. Maintain daily records using the Pest Management Maintenance Record, DD Form 1532-1, or a computer generated equivalent. These forms may be obtained from the main web site: http://www.dtic.mil/whs/directives/forms/eforms/dd1532-1.pdf 1.3.2 Qualifications For the application of herbicides, use the services of an applicator who is commercially certified in the state where the work is to be performed as required by DODI 4150.07. Submit a copy of the pesticide applicator SECTION 31 11 00 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% certificates. 1.4 DELIVERY, STORAGE, AND HANDLING Deliver materials to the site, and handle in a manner which will maintain the materials in their original manufactured or fabricated condition until ready for use. 1.4.1 Storage Storage of herbicides on the installation will not be permitted unless it is written into the contract. 1.4.2 Handling Handle herbicides in accordance with the manufacturer's label and Safety Data Sheet (SDS), preventing contamination by dirt, water, and organic material. Protect herbicides from weather elements as recommended by the manufacturer's label and SDS. Spill kits must be maintained on herbicide control vehicles. Mixing of herbicides on the installation will not be permited unless it is written into the contract. PART 2 PRODUCTS 2.1 MATERIALS 2.1.1 Tree Wound Paint Submit samples in cans with manufacturer's label of bituminous based paint of standard manufacture specially formulated for tree wounds. 2.1.2 Herbicide Provide herbicides currently registered by the EPA or approved for such use by the appropriate agency of the host county and approved by the Contracting Officer. Select a herbicide that is suitable for the climatic conditions at the project site. Submit manufacturer's label and SDS for herbicides proposed for use. PART 3 EXECUTION 3.1 PREPARATION 3.1.1 Herbicide Application Plan Prior to commencing application of herbicide, submit a herbicide application plan with proposed sequence of treatment work including dates and times of application. Include the herbicide trade name, EPA registration number, chemical composition, formulation, application rate of active ingredients, method of application, area or volume treated, and amount applied. Include a copy of the pesticide applicator certificates. 3.1.2 Protection 3.1.2.1 Roads and Walks Keep roads and walks free of dirt and debris at all times. SECTION 31 11 00 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.1.2.2 Trees, Shrubs, and Existing Facilities Protect trees and vegetation to be left standing from damage incident to clearing, grubbing, and construction operations by the erection of barriers or by such other means as the circumstances require. 3.1.2.3 Utility Lines Protect existing utility lines that are indicated to remain from damage. Notify the Contracting Officer immediately of damage to or an encounter with an unknown existing utility line. The Contractor is responsible for the repair of damage to existing utility lines that are indicated or made known to the Contractor prior to start of clearing and grubbing operations. When utility lines which are to be removed are encountered within the area of operations, notify the Contracting Officer in ample time to minimize interruption of the service. 3.2 Application 3.2.1 Herbicide Application Adhere to safety precautions as recommended by the manufacturer concerning handling and application of the herbicide. 3.2.1.1 Clean Up, Disposal, And Protection Once application has been completed, proceed with clean up and protection of the site without delay. Clean the site of all material associated with the treatment measures, according to label instructions, and as indicated. Remove and dispose of excess and waste material off Government property. 3.2.1.1.1 Disposal of Herbicide Dispose of residual herbicides and containers off Government property, and in accordance with the approved disposal plan, label instructions and EPA requirements. 3.3 CLEARING Clearing shall consist of the felling, trimming, and cutting of trees into sections and the satisfactory disposal of the trees and other vegetation designated for removal, including downed timber, snags, brush, and rubbish occurring within the areas to be cleared. Clearing shall also include the removal and disposal of structures that obtrude, encroach upon, or otherwise obstruct the work. Trees, stumps, roots, brush, and other vegetation in areas to be cleared shall be cut off flush with or below the original ground surface, except such trees and vegetation as may be indicated or directed to be left standing. Trees designated to be left standing within the cleared areas shall be trimmed of dead branches 1-1/2 inches or more in diameter and shall be trimmed of all branches the heights indicated or directed. Limbs and branches to be trimmed shall be neatly cut close to the bole of the tree or main branches. Cuts more than 1-1/2 inches in diameter shall be painted with an approved tree-wound paint. Apply herbicide in accordance with the manufacturer's label to the top surface of stumps designated not to be removed. SECTION 31 11 00 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.3.1 Tree Removal Where indicated or directed, trees and stumps that are designated as trees shall be removed from areas outside those areas designated for clearing and grubbing. This work shall include the felling of such trees and the removal of their stumps and roots as specified in paragraph GRUBBING. Trees shall be disposed of as specified in paragraph DISPOSAL OF MATERIALS. 3.3.2 Pruning Prune trees designated to be left standing within the cleared areas of dead branches 1-1/2 inches or more in diameter; and trim branches to heights and in a manner as indicated. Neatly cut limbs and branches to be trimmed close to the bole of the tree or main branches. Paint cuts more than 1-1/4 inches in diameter with an approved tree wound paint. 3.3.3 Grubbing Grubbing consists of the removal and disposal of stumps, roots larger than 3 inches in diameter, and matted roots from the designated grubbing areas. Remove material to be grubbed, together with logs and other organic or metallic debris not suitable for foundation purposes, to a depth of not less than 18 inches below the original surface level of the ground in areas indicated to be grubbed and in areas indicated as construction areas under this contract, such as areas for buildings, and areas to be paved. Fill depressions made by grubbing with suitable material and compact to make the surface conform with the original adjacent surface of the ground. 3.4 DISPOSAL OF MATERIALS 3.4.1 Saleable Timber All timber on the project site noted for clearing and grubbing shall become the property of the Contractor, and shall be removed from the project site and disposed of off stations. 3.4.2 Nonsaleable Materials Written permission to dispose of such products on private property shall be filed with the Contracting Officer. Logs, stumps, roots, brush, rotten wood, and other refuse from the clearing and grubbing operations, except for salable timber, shall be disposed of outside the limits of Government-controlled land at the Contractor's responsibility, except when otherwise directed in writing. Such directive will state the conditions covering the disposal of such products and will also state the areas in which they may be placed. 3.5 CLOSEOUT ACTIVITIES 3.5.1 Herbicides Upon completion of this work, submit the Pest Management Report DD Form 1532, or an equivalent computer product, to the Integrated Pest Management Coordinator. This form identifies the type of operation, brand name and manufacturer of herbicide, formulation, concentration or rate of application used. -- End of Section -- SECTION 31 11 00 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 31 11 00 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 31 31 16.13 CHEMICAL TERMITE CONTROL 11/14 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. U.S. DEPARTMENT OF DEFENSE (DOD) DODI 4150.07 DOD Pest Management Program 1.2 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-03 Product Data Termiticide Application Plan; G,RO Termiticides Foundation Exterior Utilities and Vents Crawl and Plenum Air Spaces Verification of Measurement Application Equipment Warranty SD-04 Samples Termiticides SD-06 Test Reports Equipment Calibration and Tank Measurement Quality Assurance SD-07 Certificates Qualifications 1.3 QUALITY ASSURANCE Comply with DODI 4150.07 for requirements on Contractor's licensing, certification, and record keeping. Maintain daily records using the Pest Management Maintenance Record, DD Form 1532-1, or a computer generated equivalent, and submit copies of records when requested by the Contracting SECTION 31 31 16.13 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Officer. These forms may be obtained from the following web link or by searching the main web site: http://www.dtic.mil/whs/directives/forms/eforms/dd1532-1.pdf Upon completion of this work, submit the Pest Management Report DD Form 1532, or an equivalent computer product, to the Integrated Pest Management Coordinator. This form identifies the target pest, type of operation, brand name and manufacturer of pesticide, formulation, concentration or rate of application used. 1.3.1 Qualifications For the application of pesticides, use the services of a applicator whose principal business is pest control. The applicator shall be licensed and certified in the state where the work is to be performed. Termiticide applicators shall also be certified in the U.S. Environmental Protection Agency (EPA) pesticide applicator category which includes structural pest control. Submit a copy of the pest control business license and pesticide applicator certificate(s). 1.3.2 Safety Requirements Formulate, treat, and dispose of termiticides and their containers in accordance with label directions. Draw water for formulating only from sites designated by the Contracting Officer, and fit the filling hose with a backflow preventer meeting local plumbing codes or standards. The filling operation shall be under the direct and continuous observation of a contractor's representative to prevent overflow. Secure pesticides and related materials under lock and key when unattended. Ensure that proper protective clothing and equipment are worn and used during all phases of termiticide application. Dispose of used pesticide containers off Government property. 1.4 DELIVERY, STORAGE, AND HANDLING 1.4.1 Delivery Deliver termiticide material to the site in the original unopened containers bearing legible labels indicating the EPA registration number and manufacturer's registered uses. All other materials, to be used on site for the purpose of termite control, shall be delivered in new or otherwise good condition as supplied by the manufacturer or formulator. 1.4.2 Inspection Inspect termiticides upon arrival at the job site for conformity to type and quality in accordance with paragraph TERMITICIDES. Each label shall bear evidence of registration under the Federal Insecticide, Fungicide, and Rodenticide Act (FIFRA), as amended or under appropriate regulations of the host county. Other materials shall be inspected for conformance with specified requirements. Remove unacceptable materials from the job site. 1.4.3 Storage Contractors shall not store pesticides on the installation unless it is written into the contract. SECTION 31 31 16.13 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.4.4 Handling Termiticides shall be handled and mixed in accordance with the manufacturer's label and SDS, preventing contamination by dirt, water, and organic material. Protect termiticides from weather elements as recommended by the manufacturer's label and SDS. Spill kits must be maintained on pest control vehicles and must be available at the mixing site. Termiticide mixing must be conducted in an area with adequate spill containment.. 1.5 SITE CONDITIONS The following conditions will determine the time of application. 1.5.1 Soil Moisture Soils to be treated shall be tested immediately before application. Test soil moisture content to a minimum depth of 3 inches. The soil moisture shall be as recommended by the termiticide manufacturer. The termiticide will not be applied when soil moisture exceeds manufacturer's recommendations because termiticides do not adhere to the soil particles in saturated soils. 1.5.2 Runoff and Wind Drift Do not apply termiticide during or immediately following heavy rains. Applications shall not be performed when conditions may cause runoff or create an environmental hazard. Applications shall not be performed when average wind speed exceeds 10 miles per hour. The termiticide shall not be allowed to enter water systems, aquifers, or endanger humans or animals. 1.5.2.1 Vapor Barriers and Waterproof Membranes Termiticide shall be applied prior to placement of a vapor barrier or waterproof membrane. 1.5.2.2 Utilities and Vents Prior to application, HVAC ducts and vents located in treatment area shall be turned off and blocked to protect people and animals from termiticide. Submit written verification that utilities and vents have been located and treated as specified. 1.5.3 Placement of Concrete Place concrete covering treated soils as soon as the termiticide has reached maximum penetration into the soil. Time for maximum penetration shall be as recommended by the manufacturer. 1.6 WARRANTY The Contractor shall provide a 5 -year written warranty against infestations or reinfestations by subterranean termites of the buildings or building additions constructed under this contract. Warranty shall include annual inspections of the buildings or building additions. If live subterranean termite infestation or subterranean termite damage is discovered during the warranty period, and the soil and building conditions have not been altered in the interim: SECTION 31 31 16.13 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% a. Retreat the soil and perform other treatment as may be necessary for elimination of subterranean termite infestation; b. Repair damage caused by termite infestation; and c. Reinspect the building approximately 180 days after the retreatment. PART 2 PRODUCTS 2.1 TERMITICIDES Submit manufacturer's label and Material Safety Data Sheet (MSDS) for termiticides proposed for use. Provide termiticides currently registered by the EPA or approved for such use by the appropriate agency of the host county. Non-repellant termiticides shall be selected for maximum effectiveness and duration after application. The selected termiticide shall be suitable for the soil and climatic conditions at the project site and applied at the highest labeled rate. Submit samples of the pesticides used in this work. The Contracting Officer may draw, at any time and without prior notice, from stocks at the job site; should analysis, performed by the Government, indicate such samples to contain less than the amount of active ingredient specified on the label, work performed with such products shall be repeated, with pesticides conforming to this specification, at no additional cost to the Government. PART 3 EXECUTION 3.1 VERIFICATION OF MEASUREMENT Once termiticide application has been completed, measure tank contents to determine the remaining volume. The total volume measurement of used contents for the application shall equal the established application rate for the project site conditions. Provide written verification that the volume of termiticide used meets the application rate. 3.2 TECHNICAL REPRESENTATIVE A DOD certified pesticide applicator or Pest Management Quality Assurance Evaluator (QAE)/Performance Assessment Representative (PAR) shall be the technical representative, shall be present at all meetings concerning treatment measures for subterranean termites, and shall be present during treatment application. The command Integrated Pest Management Coordinator shall be contacted prior to starting work. 3.3 SITE PREPARATION Work related to final grades, landscape plantings, foundations, or any other alterations to finished construction which might alter the condition of treated soils, must be coordinated with this specification. 3.3.1 Ground Preparation Eliminate food sources by removing debris from clearing and grubbing and post construction wood scraps such as ground stakes, form boards, and scrap lumber from the site, before termiticide application begins. SECTION 31 31 16.13 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.3.2 Verification Before work starts, verify that final grades are as indicated and smooth grading has been completed in accordance with Section 31 00 00 EARTHWORK. Soil particles shall be finely graded with particles no larger than 1 inch and compacted to eliminate soil movement to the greatest degree. 3.3.3 Foundation Exterior Provide written verification that final grading and landscape planting operations will not disturb treatment of the soil on the exterior sides of foundation walls, grade beams, and similar structures. 3.3.4 Utilities and Vents Provide written verification that the location and identity of HVAC ducts and vents, water and sewer lines, and plumbing have been accomplished prior to the termiticide application. 3.3.5 Crawl and Plenum Air Spaces Provide written verification that the location and identity of crawl and plenum air spaces have been accomplished prior to the termiticide application. 3.3.6 Application Plan Submit a Termiticide Application Plan with proposed sequence of treatment work with dates and times for approval before starting the specified treatment. Include the termiticide trade name, EPA registration number, chemical composition, formulation, concentration of original and diluted material, application rate of active ingredients, method of application, area/volume treated, and amount applied. Also include a copy of the pest control business license and pesticide applicator certificate(s). 3.4 TERMITICIDE TREATMENT 3.4.1 Equipment Calibration and Tank Measurement Submit a listing of equipment to be used. Immediately prior to commencement of termiticide application, calibration tests shall be conducted on the application equipment to be used and the application tank shall be measured to determine the volume and contents. These tests shall confirm that the application equipment is operating within the manufacturer's specifications and will meet the specified requirements. Submit written certification of the equipment calibration test results within 1 week of testing. 3.4.2 Mixing and Application Formulating, mixing, and application shall be performed in the presence of a DOD certified pesticide applicator, Pest Management QAE/PAR, or Integrated Pest Management Coordinator. A closed system is recommended as it prevents the termiticide from coming into contact with the applicator or other persons. Water for formulating shall only come from designated locations. Filling hoses shall be fitted with a backflow preventer meeting local plumbing codes or standards. Overflow shall be prevented during the filling operation. Spill kits must be maintained on pest control vehicles and must be available at the mixing site. Termiticide SECTION 31 31 16.13 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% mixing must be conducted in an area that has been designated by the government representative and that has adequate spill containment. Prior to each day of use, the equipment used for applying termiticides shall be inspected for leaks, clogging, wear, or damage. Any repairs are to be performed immediately. 3.4.3 Treatment Method For areas to be treated, establish complete and unbroken vertical and/or horizontal soil poison barriers between the soil and all portions of the intended structure which may allow termite access to wood and wood related products. Applications to crawl spaces shall be made in accordance with (IAW) label directions. Applications shall not be made to crawl space areas that are used as plenum air spaces. 3.4.3.1 Surface Application Use surface application for establishing horizontal barriers. Surface applicants shall be applied as a coarse spray and provide uniform distribution over the soil surface. Termiticide shall penetrate a minimum of 1 inch into the soil, or as recommended by the manufacturer. 3.4.3.2 Rodding and Trenching Use rodding and trenching for establishing vertical soil barriers. Trenching shall be to the depth of the foundation footing. Width of trench shall be as recommended by the manufacturer, or as indicated. Rodding or other approved method may be implemented for saturating the base of the trench with termiticide. Immediately after termiticide has reached maximum penetration as recommended by the manufacturer, backfilling of the trench shall commence. Backfilling shall be in 6 inch rises or layers. Each rise shall be treated with termiticide. 3.4.4 Sampling The Contracting Officer may draw from stocks at the job site, at any time and without prior notice, take samples of the termiticides used to determine if the amount of active ingredient specified on the label is being applied. 3.5 CLEAN UP, DISPOSAL, AND PROTECTION Once application has been completed, proceed with clean up and protection of the site without delay. 3.5.1 Clean Up The site shall be cleaned of all material associated with the treatment measures, according to label instructions, and as indicated. Excess and waste material shall be removed and disposed off site. 3.5.2 Disposal of Termiticide Dispose of residual termiticides and containers off Government property, and in accordance with label instructions and EPA criteria. 3.5.3 Protection of Treated Area Immediately after the application, the area shall be protected from other SECTION 31 31 16.13 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% use by erecting barricades and providing signage as required or directed. Signage shall be in accordance with Section 10 14 00.10 EXTERIOR SIGNAGE. Signage shall be placed inside the entrances to crawl spaces and shall identify the space as treated with termiticide and not safe for children and animals. Treated areas should be covered with plastic if slab is not to be poured immediately following termiticide application. 3.6 CONDITIONS FOR SATISFACTORY TREATMENT 3.6.1 Equipment Calibrations and Measurements Where results from the equipment calibration and tank measurements tests are unsatisfactory, re-treatment will be required. 3.6.2 Testing Should an analysis, performed by a third party, indicate that the samples of the applied termiticide contain less than the amount of active ingredient specified on the label, and/or if soils are treated to a depth less than specified or approved, re-treatment will be required. 3.6.3 Disturbance of Treated Soils Soil and fill material disturbed after treatment shall be re-treated before placement of slabs or other covering structures. 3.6.4 Termites Found Within the Warranty Period If live subterranean termite infestation or termite damage is discovered during the warranty period, re-treat the site. 3.7 RE-TREATMENT Where re-treatment is required, comply with the requirements specified in paragraph WARRANTY. -- End of Section -- SECTION 31 31 16.13 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 32 01 19 FIELD MOLDED SEALANTS FOR SEALING JOINTS IN RIGID PAVEMENTS 08/08 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. ASTM INTERNATIONAL (ASTM) ASTM C1016 (2014) Standard Test Method for Determination of Water Absorption of Sealant Backing (Joint Filler) Material ASTM D5893/D5893M (2016) Standard Specification for Cold Applied, Single Component, Chemically Curing Silicone Joint Sealant for Portland Cement Concrete Pavements ASTM D6690 (2015) Standard Specification for Joint and Crack Sealants, Hot Applied, for Concrete and Asphalt Pavements ASTM D789 (2015) Determination of Relative Viscosity and Moisture Content of Polyamide (PA) U.S. ARMY CORPS OF ENGINEERS (USACE) COE CRD-C 525 (1989) Corps of Engineers Test Method for Evaluation of Hot-Applied Joint Sealants for Bubbling Due to Heating U.S. GENERAL SERVICES ADMINISTRATION (GSA) FS SS-S-200 (Rev E; Am 1; Notice 1) Sealant, Joint, Two-Component, Jet-Blast-Resistant, Cold-Applied, for Portland Cement Concrete Pavement 1.2 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-03 Product Data Manufacturer's Recommendations SECTION 32 01 19 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Equipment. SD-04 Samples Materials SD-06 Test Reports Certified Copies of the Test Reports 1.3 QUALITY ASSURANCE 1.3.1 Test Requirements Test the joint sealant and backup or separating material for conformance with the referenced applicable material specification. Perform testing of the materials in an approved independent laboratory and submit certified copies of the test reports for approval 14 days prior to the use of the materials at the job site. Samples will be retained by the Government for possible future testing should the materials appear defective during or after application. Conformance with the requirements of the laboratory tests specified will not constitute final acceptance of the materials. Final acceptance will be based on the performance of the in-place materials. Submit samples of the materials (sealant, primer if required, and backup material), in sufficient quantity for testing and approval 14 days prior to the beginning of work. No material will be allowed to be used until it has been approved. 1.3.2 Trial Joint Sealant Installation Prior to the cleaning and sealing of the joints for the entire project, prepare a test section at least 200 feet long using the specified materials and approved equipment, so as to demonstrate the proposed joint preparation and sealing of all types of joints in the project. Following the completion of the test section and before any other joint is sealed, inspect the test section to determine that the materials and installation meet the requirements specified. If it is determined that the materials or installation do not meet the requirements, remove the materials, and reclean and reseal the joints at no cost to the Government. When the test section meets the requirements, it may be incorporated into the permanent work and paid for at the contract unit price per linear foot for sealing items scheduled. Prepare and seal all other joints in the manner approved for sealing the test section. 1.4 DELIVERY, STORAGE, AND HANDLING Inspect materials delivered to the job site for defects, unload, and store them with a minimum of handling to avoid damage. Provide storage facilities at the job site for maintaining materials at the temperatures and conditions recommended by the manufacturer. 1.5 ENVIRONMENTAL REQUIREMENTS The ambient air temperature and the pavement temperature within the joint wall shall be a minimum of 50 degrees F and rising at the time of application of the materials. Do not apply sealant if moisture is observed in the joint. SECTION 32 01 19 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% PART 2 PRODUCTS 2.1 SEALANTS Materials for sealing cracks in the various paved areas indicated on the drawings shall be as follows: ASTM D6690, Type III and COE CRD-C 525. 2.2 PRIMERS When primers are recommended by the manufacturer of the sealant, use them in accordance with the recommendation of the manufacturer. 2.3 BACKUP MATERIALS Provide backup material that is a compressible, nonshrinking, nonstaining, nonabsorbing material, nonreactive with the joint sealant. The material shall have a melting point at least 5 degrees F greater than the pouring temperature of the sealant being used when tested in accordance with ASTM D789. The material shall have a water absorption of not more than 5 percent of the sample weight when tested in accordance with ASTM C1016. Use backup material that is 25 plus or minus 5 percent larger in diameter than the nominal width of the crack. 2.4 BOND BREAKING TAPES Provide a bond breaking tape or separating material that is a flexible, nonshrinkable, nonabsorbing, nonstaining, and nonreacting adhesive-backed tape. The material shall have a melting point at least 5 degrees F greater than the pouring temperature of the sealant being used when tested in accordance with ASTM D789. The bond breaker tape shall be approximately 1/8 inch wider than the nominal width of the joint and shall not bond to the joint sealant. PART 3 EXECUTION 3.1 EXECUTING EQUIPMENT Machines, tools, and equipment used in the performance of the work required by this section shall be approved before the work is started maintained in satisfactory condition at all times. Submit a list of proposed equipment to be used in performance of construction work including descriptive data, 21 days prior to use on the project. 3.1.1 Joint Cleaning Equipment 3.1.1.1 Tractor-Mounted Routing Tool Provide a routing tool, used for removing old sealant from the joints, of such shape and dimensions and so mounted on the tractor that it will not damage the sides of the joints. The tool shall be designed so that it can be adjusted to remove the old material to varying depths as required. The use of V-shaped tools or rotary impact routing devices will not be permitted. Hand-operated spindle routing devices may be used to clean and enlarge random cracks. 3.1.1.2 Concrete Saw Provide a self-propelled power saw, with water-cooled diamond or abrasive saw blades, for cutting joints to the depths and widths specified or for SECTION 32 01 19 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% refacing joints or cleaning sawed joints where sandblasting does not provide a clean joint. 3.1.1.3 Sandblasting Equipment Include with the sandblasting equipment an air compressor, hose, and long-wearing venturi-type nozzle of proper size, shape and opening. The maximum nozzle opening should not exceed 1/4 inch. The air compressor shall be portable and capable of furnishing not less than 150 cfm and maintaining a line pressure of not less than 90 psi at the nozzle while in use. Demonstrate compressor capability, under job conditions, before approval. The compressor shall be equipped with traps that will maintain the compressed air free of oil and water. The nozzle shall have an adjustable guide that will hold the nozzle aligned with the joint approximately 1 inch above the pavement surface. Adjust the height, angle of inclination and the size of the nozzle as necessary to secure satisfactory results. 3.1.1.4 Waterblasting Equipment Include with the waterblasting equipment a trailer-mounted water tank, pumps, high-pressure hose, wand with safety release cutoff control, nozzle, and auxiliary water resupply equipment. Provide water tank and auxiliary resupply equipment of sufficient capacity to permit continuous operations. The nozzle shall have an adjustable guide that will hold the nozzle aligned with the joint approximately 1 inch above the pavement surface. Adjust the height, angle of inclination and the size of the nozzle as necessary to obtain satisfactory results. A pressure gauge mounted at the pump shall show at all times the pressure in psi at which the equipment is operating. 3.1.1.5 Hand Tools Hand tools may be used, when approved, for removing defective sealant from a crack and repairing or cleaning the crack faces. 3.1.2 Sealing Equipment 3.1.2.1 Hot-Poured Sealing Equipment The unit applicators used for heating and installing ASTM D6690 joint sealant materials shall be mobile and shall be equipped with a double-boiler, agitator-type kettle with an oil medium in the outer space for heat transfer; a direct-connected pressure-type extruding device with a nozzle shaped for inserting in the joint to be filled; positive temperature devices for controlling the temperature of the transfer oil and sealant; and a recording type thermometer for indicating the temperature of the sealant. The applicator unit shall be designed so that the sealant will circulate through the delivery hose and return to the inner kettle when not in use. 3.1.2.2 Two-Component, Cold-Applied, Machine Mix Sealing Equipment Provide equipment used for proportioning, mixing, and installing FS SS-S-200 Type M joint sealants designed to deliver two semifluid components through hoses to a portable mixer at a preset ratio of 1 to 1 by volume using pumps with an accuracy of plus or minus 5 percent for the quantity of each component. The reservoir for each component shall be equipped with mechanical agitation devices that will maintain the SECTION 32 01 19 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% components in a uniform condition without entrapping air. Incorporate provisions to permit thermostatically controlled indirect heating of the components, when required. However, immediately prior to proportioning and mixing, the temperature of either component shall not exceed 90 degrees F. Provide screens near the top of each reservoir to remove any foreign particles or partially polymerized material that could clog fluid lines or otherwise cause misproportioning or improper mixing of the two components. Provide equipment capable of thoroughly mixing the two components through a range of application rates of 10 to 60 gallons per hour and through a range of application pressures from 50 to 1500 psi as required by material, climatic, or operating conditions. Design the mixer for the easy removal of the supply lines for cleaning and proportioning of the components. The mixing head shall accommodate nozzles of different types and sizes as may be required by various operations. The dimensions of the nozzle shall be such that the nozzle tip will extend into the joint to allow sealing from the bottom of the joint to the top. Maintain the initially approved equipment in good working condition, serviced in accordance with the supplier's instructions, and unaltered in any way without obtaining prior approval. 3.1.2.3 Two-Component, Cold-Applied, Hand-Mix Sealing Equipment Mixing equipment for FS SS-S-200 Type H sealants shall consist of a slow-speed electric drill or air-driven mixer with a stirrer in accordance with the manufacturer's recommendations. Submit printed copies of manufacturer's recommendations, 14 days prior to use on the project, where installation procedures, or any part thereof, are required to be in accordance with those recommendations. Installation of the material will not be allowed until the recommendations are received. Failure to furnish these recommendations can be cause for rejection of the material. 3.1.2.4 Cold-Applied, Single-Component Sealing Equipment The equipment for installing ASTM D5893/D5893M single component joint sealants shall consist of an extrusion pump, air compressor, following plate, hoses, and nozzle for transferring the sealant from the storage container into the joint opening. The dimension of the nozzle shall be such that the tip of the nozzle will extend into the joint to allow sealing from the bottom of the joint to the top. Maintain the initially approved equipment in good working condition, serviced in accordance with the supplier's instructions, and unaltered in any way without obtaining prior approval. Small hand-held air-powered equipment (i.e., caulking guns) may be used for small applications. 3.2 SAFETY Do not place joint sealant within 25 feet of any liquid oxygen (LOX) equipment, LOX storage, or LOX piping. Thoroughly clean joints in this area and leave them unsealed. 3.3 PREPARATION OF JOINTS Immediately before the installation of the sealant, thoroughly clean the joints to remove all laitance, curing compound, filler, protrusions of hardened concrete, and old sealant from the sides and upper edges of the joint space to be sealed. SECTION 32 01 19 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.3.1 Existing Sealant Removal Cut loose the in-place sealant from both joint faces and to the depth shown on the drawings, using the tractor-mounted routing equipment, concrete saw, or waterblaster as specified in paragraph EQUIPMENT. Depth shall be sufficient to accommodate any separating or backup material that is required to maintain the depth of new sealant to be installed. Prior to further cleaning operations, remove all loose old sealant remaining in the joint opening by blowing with compressed air. Hand tools may be required to remove sealant from random cracks. Chipping, spalling, or otherwise damaging the concrete will not be allowed. 3.3.2 Sawing 3.3.2.1 Refacing of Random Cracks Accomplish sawing of the cracks using a power-driven concrete saw as specified in paragraph EQUIPMENT. The saw blade shall be 6 inches or less in diameter to enable the saw to follow the trace of the crack. Stiffen the blade, as necessary, with suitable dummy (or used) blades or washers. Immediately following the sawing operation, thoroughly clean the crack opening using a water jet to remove all saw cuttings and debris. 3.3.3 Sandblasting The newly exposed concrete joint faces and the pavement surfaces extending a minimum of 1/2 inch from the joint edges shall be sandblasted or waterblasted clean. use a multiple-pass technique until the surfaces are free of dust, dirt, curing compound, filler, old sealant residue, or any foreign debris that might prevent the bonding of the sealant to the concrete. After final cleaning and immediately prior to sealing, blow out the joints with compressed air and leave them completely free of debris and water. 3.3.4 Back-Up Material When the joint opening is of a greater depth than indicated for the sealant depth, plug or seal off the lower portion of the joint opening using a back-up material to prevent the entrance of the sealant below the specified depth. Take care to ensure that the backup material is placed at the specified depth and is not stretched or twisted during installation. 3.3.5 Bond Breaking Tape Where inserts or filler materials contain bitumen, or the depth of the joint opening does not allow for the use of a backup material, insert a bond breaker separating tape to prevent incompatibility with the filler materials and three-sided adhesion of the sealant. Securely bond the tape to the bottom of the joint opening so it will not float up into the new sealant. 3.3.6 Rate of Progress of Joint Preparation Limit the stages of joint preparation, which include sandblasting, air pressure cleaning and placing of the back-up material to only that lineal footage that can be sealed during the same day. SECTION 32 01 19 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.4 PREPARATION OF SEALANT 3.4.1 Hot-Poured Sealants Do not heat sealants conforming to ASTM D6690 in excess of the safe heating temperature recommended by the manufacturer as shown on the sealant containers. Withdraw and waste sealant that has been overheated or subjected to application temperatures for over 4 hours or that has remained in the applicator at the end of the day's operation. 3.4.2 Type M Sealants Inspect the FS SS-S-200 Type M sealant components and containers prior to use. Reject any materials that contain water, hard caking of any separated constituents, nonreversible jell, or materials that are otherwise unsatisfactory. Settlement of constituents in a soft mass that can be readily and uniformly remixed in the field with simple tools will not be cause for rejection. Prior to transfer of the components from the shipping containers to the appropriate reservoir of the application equipment, thoroughly mix the materials to ensure homogeneity of the components and incorporation of all constituents at the time of transfer. When necessary for remixing prior to transfer to the application equipment reservoirs, warm the components to a temperature not to exceed 90 degrees F by placing the components in heated storage or by other approved methods but in no case shall the components be heated by direct flame, or in a single walled kettle, or a kettle without an oil bath. 3.4.3 Type H Sealants Mix the FS SS-S-200 Type H sealant components either in the container furnished by the manufacturer or a cylindrical metal container of volume approximately 50 percent greater than the package volume. Thoroughly mix the base material in accordance with the manufacturer's instructions. The cure component shall then be slowly added during continued mixing until a uniform consistency is obtained. 3.4.4 Single-Component, Cold-Applied Sealants Inspect the ASTM D5893/D5893M sealant and containers prior to use. Reject any materials that contain water, hard caking of any separated constituents, nonreversible jell, or materials that are otherwise unsatisfactory. Settlement of constituents in a soft mass that can be readily and uniformly remixed in the field with simple tools will not be cause for rejection. 3.5 INSTALLATION OF SEALANT 3.5.1 Time of Application Seal joints immediately following final cleaning of the joint walls and following the placement of the separating or backup material. Open joints, that cannot be sealed under the conditions specified, or when rain interrupts sealing operations shall be recleaned and allowed to dry prior to installing the sealant. 3.5.2 Sealing Joints Immediately preceding, but not more than 50 feet ahead of the joint sealing operations, perform a final cleaning with compressed air. Fill SECTION 32 01 19 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% the joints from the bottom up to 1/4 inch plus or minus 1/16 inch below the pavement surface. Remove and discard excess or spilled sealant from the pavement by approved methods. Install the sealant in such a manner as to prevent the formation of voids and entrapped air. In no case shall gravity methods or pouring pots be used to install the sealant material. Traffic shall not be permitted over newly sealed pavement until authorized by the Contracting Officer. When a primer is recommended by the manufacturer, apply it evenly to the joint faces in accordance with the manufacturer's instructions. Check the joints frequently to ensure that the newly installed sealant is cured to a tack-free condition within the time specified. 3.6 INSPECTION 3.6.1 Joint Cleaning Inspect joints during the cleaning process to correct improper equipment and cleaning techniques that damage the concrete pavement in any manner. Cleaned joints will be approved prior to installation of the separating or back-up material and joint sealant. 3.6.2 Joint Sealant Application Equipment Inspect the application equipment to ensure conformance to temperature requirements, proper proportioning and mixing (if two-component sealant) and proper installation. Evidences of bubbling, improper installation, failure to cure or set will be cause to suspend operations until causes of the deficiencies are determined and corrected. 3.6.3 Joint Sealant Inspect the joint sealant for proper rate of cure and set, bonding to the joint walls, cohesive separation within the sealant, reversion to liquid, entrapped air and voids. Sealants exhibiting any of these deficiencies at any time prior to the final acceptance of the project shall be removed from the joint, wasted, and replaced as specified herein at no additional cost to the Government. 3.7 CLEAN-UP Upon completion of the project, remove all unused materials from the site and leave the pavement in a clean condition. -- End of Section -- SECTION 32 01 19 Page 8 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 32 05 33 LANDSCAPE ESTABLISHMENT 08/17 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. ASTM INTERNATIONAL (ASTM) ASTM D5851 (1995; R 2015) Planning and Implementing a Water Monitoring Program ASTM D6155 (2015) Nontraditional Coarse Aggregate for Bituminous Paving Mixtures 1.2 DEFINITIONS 1.2.1 Pesticide Any substance or mixture of substances, including biological control agents, that may prevent, destroy, repel, or mitigate pests and are specifically labeled for use by the U.S. Environmental Protection Agency (EPA). Also, any substance used as a plant regulator, defoliant, disinfectant, or biocide. Examples of pesticides include fumigants, herbicides, insecticides, fungicides, nematicides, molluscicides and rodenticides. 1.2.2 Stand of Turf 100 percent ground cover of the established species. 1.2.3 Planter Beds A planter bed is defined as an area containing one or a combination of the following plant types: shrubs, vines, wildflowers, annuals, perennials, ground cover, and a mulch topdressing excluding turf. Trees may also be found in planter beds. 1.3 RELATED REQUIREMENTS Section 32 92 19 SEEDING applies to this section for installation of seed requirements, with additions and modifications herein. 1.4 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SECTION 32 05 33 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SD-01 Preconstruction Submittals Integrated Pest Management Plan SD-07 Certificates Maintenance Inspection Report SD-10 Operation and Maintenance Data Maintenance 1.5 DELIVERY, STORAGE AND HANDLING 1.5.1 Delivery Deliver fertilizer, gypsum, iron to the site in original containers bearing manufacturer's chemical analysis, name, trade name, or trademark, and indication of conformance to state and federal laws. Instead of containers, fertilizer, gypsum may be furnished in bulk with a certificate indicating the above information. 1.5.2 Storage 1.5.2.1 Fertilizer, Lime, Iron, Mulch Storage Store material in designated areas. Store lime and fertilizer in cool, dry locations away from contaminants. 1.5.2.2 Antidesiccant's Storage Do not store with fertilizers or other landscape maintenance materials. 1.5.3 Handling Do not drop or dump materials from vehicles. 1.6 MAINTENANCE Submit Operation and Maintenance (O&M) Manuals for planting materials. Include instructions indicating procedures during one typical year including variations of maintenance for climatic conditions throughout the year. Provide instructions and procedures for watering; promotion of growth, including fertilizing, pruning, and mowing; and integrated pest management. O&M Manuals must include pictures of planting materials cross referenced to botanical and common names, with a description of the normal appearance in each season. Develop a water monitoring program for surface and ground water on the project site in accordance with ASTM D5851 and consistent with the water management program utilized during construction operations. 1.7 Fort Bragg Installation Design Guide Refer to Fort Bragg Installation Design Guide (FBIDG) for more information on landscaping requirements. SECTION 32 05 33 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% PART 2 PRODUCTS 2.1 POST-PLANT FERTILIZER Fertilizer for groundcover, wildflowers, and grasses is not permitted. Provide fertilizer for trees, plants, and shrubs as recommended by plant supplier, except synthetic chemical fertilizers are not permitted. Fertilizers containing petrochemical additives or that have been treated with pesticides or herbicides are not permitted. 2.1.1 Granular Fertilizer Organic, granular controlled release fertilizer containing the following minimum percentages, by weight, of plant food nutrients: 20 percent available nitrogen 20 percent available phosphorus 20 percent available potassium 5 percent sulfur 5 percent iron 2.2 WATER Source of water must be approved by the Contracting Officer, and be of suitable quality for irrigation. Use collected storm water or graywater when available. 2.3 MULCHES TOPDRESSING Free from noxious weeds, mold, pesticides, or other deleterious materials. 2.3.1 Inert Mulch Materials Provide stone, complying with ASTM D6155, ranging in size from 4 to 6 inches. 2.3.2 Organic Mulch Materials Provide wood chips, shredded hardwood, from site when available. Wood cellulose fiber must be processed to contain no growth or germination-inhibiting factors, dyed with non-toxic, biodegradable dye to an appropriate color to facilitate visual metering of materials application. Paper-based hydraulic mulch must contain a minimum of 100 percent post-consumer recycled content. Wood-based hydraulic mulch must contain a minimum of 100 percent total recovered materials content. 2.3.3 Recycled Organic Mulch Recycled mulch may include compost, tree trimmings, or pine needles with a gradation that passes through a 2-1/2 by 2-1/2 inch screen. Clean recycled mulch of all sticks a minimum one inch in diameter and plastic materials a minimum 3 inch length. The material must be treated to retard the growth of mold and fungi. 2.4 PESTICIDES Pesticides and herbicides are not permitted. Submit an Integrated Pest Management Plan, including weed and pest management strategies. Use biological pest controls as approved in the Plan. SECTION 32 05 33 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% PART 3 EXECUTION 3.1 EXTENT OF WORK Provide landscape construction maintenance to include mowing, edging, overseeding, aeration, fertilizing, watering, and weeding, for all newly installed landscape areas and existing plant material, unless indicated otherwise, and at all areas inside or outside the limits of the construction that are disturbed by the Contractor's operations. 3.1.1 Policing Police all landscaped areas. Policing includes removal of leaves, branches and limbs regardless of length or diameter, dead vegetation, paper, trash, cigarette butts, garbage, rocks or other debris. Policing must extend to both sides of fencing or walls. Collected debris must be promptly removed and disposed of at an approved disposal site. 3.1.2 Drainage System Maintenance Remove all obstructions from surface and subsurface drain lines to allow water to flow unrestricted in swales, gutters, catch basins, and storm drain curb inlets. Remove grates and clear debris in catch basins. Open drainage channels are to be maintained free of all debris and vegetation at all times. Edges of these channels must be clear of any encroachment by vegetation. 3.2 GROUNDCOVER ESTABLISHMENT PERIOD Groundcover establishment period will commence on the date that inspection by the Contracting Officer shows that the new turf furnished under this contract has been satisfactorily installed to a 100 percent stand of coverage. The establishment period must continue for a period of 365 days. 3.2.1 Frequency of Maintenance Begin maintenance immediately after turf has been installed. Inspect area once a week during the installation and establishment period and perform needed maintenance promptly. 3.2.2 Promotion of Growth Maintain groundcover in a manner that promotes proper health, growth, natural color. Turf must have a neat uniform manicured appearance, free of bare areas, ruts, holes, weeds, pests, dead vegetation, debris, and unwanted vegetation that present an unsightly appearance. Mow, remove excess clippings, eradicate weeds, water, fertilize, overseed, aerate, topdress and perform other operations necessary to promote growth, as approved by Contracting Officer and consistent with approved Integrated Pest Management Plan. Remove noxious weeds common to the area from planting areas by mechanical means. 3.2.3 Mowing 3.2.3.1 Turf Mow turf at a uniform finished height. Mow turfed areas to a minimum average height of 4 inches when average height of grass becomes 6 inches SECTION 32 05 33 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% for spring/summer maintenance and to a minimum average height of 4 inches when the average height of grass reaches 6 inches for fall maintenance. The height of turf is measured from the soil. Perform mowing of turf in a manner that prevents scalping, rutting, bruising, uneven and rough cutting. Prior to mowing, all rubbish, debris, trash, leaves, rocks, paper, and limbs or branches on a turf area must be picked up and disposed. Adjacent paved areas must be swept/vacuumed clean. 3.2.3.2 Native Grasses Mow above height of native grass seedlings (approximately 3.5 to 4 inches ). Mow during spring or early summer. Do not mow after early summer during the second growing season. 3.2.3.3 Wildflowers Mow three times per season above height of the wildflowers (approximately 12 to 15 inches). 3.2.4 Turf Edging and Trimming Perimeter of planter bed edges, sidewalks, driveways, curbs, and other paved surfaces must be edged. Uniformly edge these areas to prevent encroachment of vegetation onto paved surfaces and to provide a clear cut division line between planter beds, turf, and ground cover. Edging is to be accomplished in a manner that prevents scalping, rutting, bruising, uneven and rough cutting. Perform edging on the same day that turf is mowed. Use of string line trimmers is permitted in "soft" areas such as an edge between turfgrass and a planter bed. Exercise care to avoid damage to any plant materials, structures, and other landscape features. Trimming around trees, fences, poles, walls, and other similar objects is to be accomplished to match the height and appearance of surrounding mowed turf growth. Trimming must be performed on the same day the turf's mowed. Care must be exercised to avoid "Girdling" trees located in turf areas. The use of protective tree collars on trees in turf areas may be utilized as a temporary means to avoid injury to tree trunks. At the end of the plant establishment period Contractor will be responsible for removing all protective tree collars. 3.2.5 Post-Fertilizer Application Do not fertilize wildflowers, groundcover, and grasses. Apply turf fertilizer in a manner that promotes health, growth, vigor, color and appearance of cultivated turf areas. The method of application, fertilizer type and frequencies must be determined by the laboratory soil analysis results the requirements of the particular turf species. Organic fertilizer must be used. In the event that organic fertilizer is not producing the desired effect, the Contractor must contract the Contracting Officer for approval prior to the use of a synthetic type of fertilizer. Apply fertilizer by approved methods in accordance with the manufacturer's recommendations. 3.2.6 Turf Watering Perform irrigation in a manner that promotes the health, growth, color and appearance of cultivated vegetation and that complies with all Federal, State, and local water agencies and authorities directives. The Contractor must be responsible to prevent over watering, water run-off, SECTION 32 05 33 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% erosion, and ponding due to excessive quantities or rate of application. Abide by state, local or other water conservation regulations or restrictions in force during the establishment period. 3.2.7 Turf Aeration Upon completion of weed eradication operations and Contracting Officer's approval to proceed, aerate turf areas by approved device. Core, by pulling soil plugs, to a minimum depth of 2 inches. Leave all soil plugs that are produced in the turf area. After aeration operations are complete, topdress entire area 1/2 inch depth with the following mixture: 2 percent sand 20 percent humus 10 percent gypsum 20 percent lime Blend all parts of topdressing mixture to a uniform consistency throughout. Keep clean at all times at least one paved pedestrian access route and one paved vehicular access route to each building. Clean all soil plugs off of other paving when work is complete. This work must commence 24 days prior final acceptance of the maintenance establishment period. 3.2.8 Turf Clearance Area Trees located in turf areas must be maintained with a growth free clearance of 18 inches from the tree trunk base. The use of mechanical weed whips to accomplish the turf growth free bed area is prohibited. 3.2.9 Replanting Replant in accordance with Section 32 92 19 SEEDING and within specified planting dates areas which do not have a satisfactory stand of turf. Replant areas which do not have a satisfactory stand of other groundcover and grasses. 3.2.10 Final Inspection and Acceptance Final inspection will be make upon written request from the Contractor at least 10 days prior to the last day of the turf establishment period. Final turf acceptance will be based upon a satisfactory stand of turf. Final acceptance of wildflower and grass areas will be based upon a stand of 100 percent groundcover of established species. 3.2.11 Unsatisfactory Work When work is found to not meet design intent and specifications, maintenance period will be extended at no additional cost to the Government until work has been completed, inspected and accepted by Contracting Officer. 3.3 EXTERIOR PLANT ESTABLISHMENT PERIOD The exterior plant establishment period will commence on the date that inspection by the Contracting Officer shows that the new plants furnished under this contract have been satisfactorily installed and must continue for a period of 365 days. SECTION 32 05 33 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.3.1 Frequency of Maintenance Begin maintenance immediately after plants have been installed. Inspect exterior plants at least once a week during the installation and establishment period and perform needed maintenance promptly. 3.3.2 Promotion of Plant Growth and Vigor Water, prune, fertilize, mulch, adjust stakes, guys and turnbuckles, eradicate weeds and perform other operations necessary to promote plant growth, and vigor. 3.3.3 Planter Bed Maintenance Planter beds must be weeded, fertilized, irrigated, kept pest free, turf free, pruned, and mulch levels maintained. Planter beds will not be allowed to encroach into turf areas. A definite break must be maintained between turf areas and planter beds. Fertilize exterior planting materials to promote healthy plant growth without encouraging excessive top foliar growth. Remove noxious weeds common to the area from planting areas by mechanical means. 3.3.3.1 Shrub Selective Maintenance In addition to the above requirements, shrubs must be selectively pruned, and shaped for health and safety when the following conditions exist: Remove growth in front of windows, over entrance ways or walks, and any growth which will obstruct vision at street intersections or of security personnel; Remove dead, damaged or diseased branches or limbs; where shrub growth obstructs pedestrian walkways; where shrub growth is found growing against or over structures; where shrub growth permits concealment of unauthorized persons. Dispose of all pruning debris in a proper manner. 3.3.4 Slope Erosion Control Maintenance Provide slope erosion control maintenance to prevent undermining of all slopes in newly landscaped and natural growth areas. Maintenance tasks include immediate repairs to weak spots in sloped areas, and maintaining clean, clear culverts, and graded berms, to intercept and direct water flow to prevent development of large gullies and slope erosion Eroded areas must be filled with amended topsoil and replanted with the same plant species. Erosion control netting and/or blankets damaged due to slope erosion must be reinstalled. 3.3.5 Removal of Dying or Dead Plants Remove dead and dying plants and provide new plants immediately upon commencement of the specified planting season, and replace mulch and eroded earth mound water basins. Provide an additional 90 day establishment period for replacement plants beyond the original warranty period. A tree must be considered dying or dead when the main leader has died back, or a minimum of 20 percent of the crown has died. A shrub or ground cover must be considered dying or dead when a minimum of 20 percent of the plant has died. This condition must be determined by scraping on a branch an area 1/16 inch square, maximum, to determine the cause for dying plant material and must provide recommendations for replacement. The Contractor must determine the cause for dying plant material and provide recommendations for replacement. SECTION 32 05 33 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.3.6 Tracking of Unhealthy Plants Note plants not in healthy growing condition, as determined by the Contracting Officer, and as soon as seasonal conditions permit, remove and replace with plants of the same species and sizes as originally specified. Install replacement plantings. 3.3.7 Final Inspection Final inspection will be made upon written request from the Contractor at least 10 days prior to the last day of the establishment period. Final inspection will be based upon satisfactory health and growth of plants and on the following: 3.3.7.1 Total Plants on Site Plants have been accepted and required number of replacements have been installed. 3.3.7.2 Mulching and Weeding Planter beds and earth mound water basins are properly mulched and free of weeds. 3.3.7.3 Remedial Work Remedial measures directed by the Contracting Officer to ensure plant material survival and promote healthy growth have been completed. 3.3.8 Unsatisfactory Work When work is found to not meet design intent and specifications, maintenance period will be extended at no additional cost to the Government until work has been completed, inspected and accepted by Contracting Officer. 3.4 FIELD QUALITY CONTROL 3.4.1 Maintenance Inspection Report Provide maintenance inspection report to assure that landscape maintenance is being performed in accordance with the specifications and in the best interest of plant growth and survivability. Site observations must be documented at the start of the establishment period, then quarterly following the start, and at the end of establishment period. Submit results of site observation visits to the Contracting Officer within 7 calendar days of each site observation visit. 3.4.2 Tree Staking and Guying Removal Provide a certified letter that all stakes and guys are removed from all project trees at the end of the establishment period. -- End of Section -- SECTION 32 05 33 Page 8 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 32 11 23 AGGREGATE BASE COURSES 08/17 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by basic designation only. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO) AASHTO T 180 (2017) Standard Method of Test for Moisture-Density Relations of Soils Using a 4.54-kg (10-lb) Rammer and a 457-mm (18-in.) Drop AASHTO T 224 (2010) Standard Method of Test for Correction for Coarse Particles in the Soil Compaction Test AASHTO T 88 (2013) Standard Method of Test for Particle Size Analysis of Soils ASTM INTERNATIONAL (ASTM) ASTM C117 (2017) Standard Test Method for Materials Finer than 75-um (No. 200) Sieve in Mineral Aggregates by Washing ASTM C127 (2015) Standard Test Method for Density, Relative Density (Specific Gravity), and Absorption of Coarse Aggregate ASTM C128 (2015) Standard Test Method for Density, Relative Density (Specific Gravity), and Absorption of Fine Aggregate ASTM C131/C131M (2014) Standard Test Method for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine ASTM C136/C136M (2014) Standard Test Method for Sieve Analysis of Fine and Coarse Aggregates ASTM C29/C29M (2017a) Standard Test Method for Bulk Density ("Unit Weight") and Voids in Aggregate ASTM C88 (2013) Standard Test Method for Soundness of Aggregates by Use of Sodium Sulfate or Magnesium Sulfate SECTION 32 11 23 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% ASTM D1556/D1556M (2015; E 2016) Standard Test Method for Density and Unit Weight of Soil in Place by Sand-Cone Method ASTM D1557 (2012; E 2015) Standard Test Methods for Laboratory Compaction Characteristics of Soil Using Modified Effort (56,000 ft-lbf/ft3) (2700 kN-m/m3) ASTM D2167 (2015) Density and Unit Weight of Soil in Place by the Rubber Balloon Method ASTM D2487 (2017) Standard Practice for Classification of Soils for Engineering Purposes (Unified Soil Classification System) ASTM D4318 (2017) Standard Test Methods for Liquid Limit, Plastic Limit, and Plasticity Index of Soils ASTM D5821 (2013; R 2017) Standard Test Method for Determining the Percentage of Fractured Particles in Coarse Aggregate ASTM D6938 (2017a) Standard Test Method for In-Place Density and Water Content of Soil and Soil-Aggregate by Nuclear Methods (Shallow Depth) ASTM D75/D75M (2014) Standard Practice for Sampling Aggregates ASTM E11 (2016) Standard Specification for Woven Wire Test Sieve Cloth and Test Sieves 1.2 DEFINITIONS For the purposes of this specification, the following definitions apply. 1.2.1 Aggregate Base Course Aggregate base course (ABC) is well graded, durable aggregate uniformly moistened and mechanically stabilized by compaction. 1.2.2 Graded-Crushed Aggregate Base Course Graded-crushed aggregate (GCA) base course is well graded, crushed, durable aggregate uniformly moistened and mechanically stabilized by compaction. 1.2.3 Degree of Compaction Degree of compaction required, except as noted in the second sentence, is expressed as a percentage of the maximum laboratory dry density obtained by the test procedure presented in ASTM D1557 abbreviated as a percent of laboratory maximum dry density. Since ASTM D1557 applies only to soils that have 30 percent or less by weight of their particles retained on the SECTION 32 11 23 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3/4 inch sieve, the degree of compaction for material having more than 30 percent by weight of their particles retained on the 3/4 inch sieve will be expressed as a percentage of the laboratory maximum dry density in accordance with AASHTO T 180 Method D and corrected with AASHTO T 224. 1.3 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-03 Product Data Plant, Equipment, and Tools SD-06 Test Reports Initial Tests 1.4 EQUIPMENT, TOOLS, AND MACHINES All plant, equipment, and tools used in the performance of the work will be subject to approval by the Contracting Officer before the work is started. Maintain all plant, equipment, and tools in satisfactory working condition at all times. Submit a list of proposed equipment, including descriptive data. Use equipment capable of minimizing segregation, producing the required compaction, meeting grade controls, thickness control, and smoothness requirements as set forth herein. 1.5 QUALITY ASSURANCE Sampling and testing are the responsibility of the Contractor. Perform sampling and testing using a laboratory approved in accordance with Section 01 45 00.00 10 QUALITY CONTROL. Work requiring testing will not be permitted until the testing laboratory has been inspected and approved. Test the materials to establish compliance with the specified requirements and perform testing at the specified frequency. The Contracting Officer may specify the time and location of the tests. Furnish copies of test results to the Contracting Officer within 24 hours of completion of the tests. 1.5.1 Sampling Take samples for laboratory testing in conformance with ASTM D75/D75M. When deemed necessary, the sampling will be observed by the Contracting Officer. 1.5.2 Tests 1.5.2.1 Sieve Analysis Perform sieve analysis in conformance with ASTM C117 and ASTM C136/C136M using sieves conforming to ASTM E11. SECTION 32 11 23 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.5.2.2 Liquid Limit and Plasticity Index Determine liquid limit and plasticity index in accordance with ASTM D4318. 1.5.2.3 Moisture-Density Determinations Determine the laboratory maximum dry density and optimum moisture content in accordance with paragraph DEGREE OF COMPACTION. 1.5.2.4 Field Density Tests Measure field density in accordance with ASTM D1556/D1556M, ASTM D2167 or ASTM D6938. For the method presented in ASTM D1556/D1556M use the base plate as shown in the drawing. For the method presented in ASTM D6938 check the calibration curves and adjust them, if necessary, using only the sand cone method as described in paragraph Calibration, of the ASTM publication. Tests performed in accordance with ASTM D6938 result in a wet unit weight of soil and ASTM D6938 will be used to determine the moisture content of the soil. Also check the calibration curves furnished with the moisture gauges along with density calibration checks as described in ASTM D6938. Make the calibration checks of both the density and moisture gauges using the prepared containers of material method, as described in paragraph Calibration of ASTM D6938, on each different type of material being tested at the beginning of a job and at intervals as directed. Submit calibration curves and related test results prior to using the device or equipment being calibrated. 1.5.2.5 Wear Test Perform wear tests on ABC and GCA course material in conformance with ASTM C131/C131M. 1.5.2.6 Soundness Perform soundness tests on GCA in accordance with ASTM C88. 1.5.2.7 Weight of Slag Determine weight per cubic foot of slag in accordance with ASTM C29/C29M on the ABC and GCA course material. 1.6 ENVIRONMENTAL REQUIREMENTS Perform construction when the atmospheric temperature is above 35 degrees F. When the temperature falls below 35 degrees F, protect all completed areas by approved methods against detrimental effects of freezing. Correct completed areas damaged by freezing, rainfall, or other weather conditions to meet specified requirements. PART 2 PRODUCTS 2.1 AGGREGATES Provide ABC and GCA consisting of clean, sound, durable particles of crushed stone, crushed slag, crushed gravel, crushed recycled concrete, angular sand, or other approved material. Provide ABC that is free of lumps of clay, organic matter, and other objectionable materials or coatings. Provide GCA that is free of silt and clay as defined by ASTM D2487, organic matter, and other objectionable materials or coatings. SECTION 32 11 23 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% The portion retained on the No. 4 sieve is known as coarse aggregate; that portion passing the No. 4 sieve is known as fine aggregate. When the coarse and fine aggregate is supplied form more than one source, provide aggregate from each source that meets the specified requirements. All aggregates shall meet NCDOT Standard Specifications. 2.1.1 Coarse Aggregate Provide coarse aggregates with angular particles of uniform density. Separately stockpile coarse aggregate supplied from more than one source. a. Crushed Gravel: Provide crushed gravel that has been manufactured by crushing gravels and that meets all the requirements specified below. b. Crushed Stone: Provide crushed stone consisting of freshly mined quarry rock, meeting all the requirements specified below. c. Crushed Recycled Concrete: Provide crushed recycled concrete consisting of previously hardened portland cement concrete or other concrete containing pozzolanic binder material. Provide recycled concrete that is free of all reinforcing steel, bituminous concrete surfacing, and any other foreign material and that has been crushed and processed to meet the required gradations for coarse aggregate. Reject recycled concrete aggregate exceeding this value. Provide crushed recycled concrete that meets all other applicable requirements specified below. d. Crushed Slag: Provide crushed slag that is an air-cooled blast-furnace product having an air dry unit weight of not less than 70 pcf as determined by ASTM C29/C29M, and meets all the requirements specified below. 2.1.1.1 Aggregate Base Course The percentage of loss of ABC coarse aggregate must not exceed 50 percent when tested in accordance with ASTM C131/C131M. Provide aggregate that contains no more than 30 percent flat and elongated particles. A flat particle is one having a ratio of width to thickness greater than 3; an elongated particle is one having a ratio of length to width greater than 3. In the portion retained on each sieve specified, the crushed aggregates must contain at least 50 percent by weight of crushed pieces having two or more freshly fractured faces determined in accordance with ASTM D5821. When two fractures are contiguous, the angle between planes of the fractures must be at least 30 degrees in order to count as two fractured faces. Manufacture crushed gravel from gravel particles 50 percent of which, by weight, are retained on the maximum size sieve listed in TABLE 1. 2.1.1.2 Graded-Crushed Aggregate Base Course The percentage of loss of GCA coarse aggregate must not exceed 50 percent loss when tested in accordance with ASTM C131/C131M. Provide GCA coarse aggregate that does not exhibit a loss greater than 18 percent weighted average, at five cycles, when tested for soundness in magnesium sulfate, or 12 percent weighted average, at five cycles, when tested in sodium sulfate in accordance with ASTM C88. Provide aggregate that contains no more than 20 percent flat and elongated particles for the fraction retained on the 1/2 inch sieve nor 20 percent for the fraction passing the 1/2 inch sieve. A flat particle is one having a ratio of width to SECTION 32 11 23 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% thickness greater than 3; an elongated particle is one having a ratio of length to width greater than 3. In the portion retained on each sieve specified, the crushed aggregate must contain at least 90 percent by weight of crushed pieces having two or more freshly fractured faces determined in accordance with ASTM D5821. When two fractures are contiguous, the angle between planes of the fractures must be at least 30 degrees in order to count as two fractured faces. Manufacture crushed gravel from gravel particles 90 percent of which by weight are retained on the maximum size sieve listed in TABLE 1. 2.1.2 Fine Aggregate Provide fine aggregates consisting of angular particles of uniform density. 2.1.2.1 Aggregate Base Course Provide ABC fine aggregate that consists of screenings, angular sand, crushed recycled concrete fines, or other finely divided mineral matter processed or naturally combined with the coarse aggregate. 2.1.2.2 Graded-Crushed Aggregate Base Course Provide GCA fine aggregate consisting of angular particles produced by crushing stone, slag, recycled concrete, or gravel that meets the requirements for wear and soundness specified for GCA coarse aggregate. Produce fine aggregate by crushing only particles larger than No. 4 sieve in size. Provide fine aggregate that contains at least 90 percent by weight of particles having two or more freshly fractured faces in the portion passing the No. 4 sieve and retained on the No. 10 sieve, and in the portion passing the No. 10 sieve and retained on the No. 40 sieve. 2.1.3 Gradation Requirements Apply the specified gradation requirements to the completed base course. Provide aggregates that are continuously well graded within the limits specified in TABLE 1. Use sieves that conform to ASTM E11. TABLE 1. GRADATION OF AGGREGATES Percentage by Weight Passing Square-Mesh Sieve Sieve Designation ABC ------------------------ 2 inch ---- 1-1/2 inch 100 1 inch 75-97 1/2 inch 55-80 No. 4 35-55 No. 10 25-45 No. 40 14-30 No. 200 4-12 NOTE 1: Particles having diameters less than 0.02 mm must not be in excess of 3 percent by weight of the total sample tested as determined in accordance with AASHTO T 88. NOTE 2: The values are based on aggregates of uniform specific gravity. SECTION 32 11 23 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% If materials from different sources are used for the coarse and fine aggregates, test the materials in accordance with ASTM C127 and ASTM C128 to determine their specific gravities. Correct the percentages passing the various sieves as directed by the Contracting Officer if the specific gravities vary by more than 10 percent. 2.2 LIQUID LIMIT AND PLASTICITY INDEX Apply liquid limit and plasticity index requirements to the completed course and to any component that is blended to meet the required gradation. The portion of any component or of the completed course passing the No. 40 sieve must be either nonplastic or have a liquid limit not greater than 25 and a plasticity index not greater than 5. 2.3 TESTS, INSPECTIONS, AND VERIFICATIONS 2.3.1 Initial Tests Perform one of each of the following tests, on the proposed material prior to commencing construction, to demonstrate that the proposed material meets all specified requirements when furnished. Complete this testing for each source if materials from more than one source are proposed. a. Sieve Analysis. b. Liquid limit and plasticity index. c. Moisture-density relationship. d. Wear. e. Soundness. f. Weight per cubic foot of Slag. Submit certified copies of test results for approval not less than 30 days before material is required for the work. 2.3.2 Approval of Material Tentative approval of material will be based on initial test results. PART 3 EXECUTION 3.1 GENERAL REQUIREMENTS When the ABC or GCA is constructed in more than one layer, clean the previously constructed layer of loose and foreign matter by sweeping with power sweepers or power brooms, except that hand brooms may be used in areas where power cleaning is not practicable. Provide adequate drainage during the entire period of construction to prevent water from collecting or standing on the working area. 3.2 OPERATION OF AGGREGATE SOURCES Clearing, stripping, and excavating are the responsibility of the Contractor. Condition aggregate sources on Government property to readily drain and leave in a satisfactory condition upon completion of the work. SECTION 32 11 23 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.3 STOCKPILING MATERIAL Clear and level storage sites prior to stockpiling of material. Stockpile all materials, including approved material available from excavation and grading, in the manner and at the locations designated. Stockpile aggregates on the cleared and leveled areas designated by the Contracting Officer to prevent segregation. Stockpile materials obtained from different sources separately. 3.4 PREPARATION OF UNDERLYING COURSE OR SUBGRADE Clean the underlying course or subgrade of all foreign substances prior to constructing the base course(s). Do not construct base course(s) on underlying course or subgrade that is frozen. Construct the surface of the underlying course or subgrade to meet specified compaction and surface tolerances. Correct ruts or soft yielding spots in the underlying courses, areas having inadequate compaction, and deviations of the surface from the specified requirements set forth herein by loosening and removing soft or unsatisfactory material and adding approved material, reshaping to line and grade, and recompacting to specified density requirements. For cohesionless underlying courses or subgrades containing sands or gravels, as defined in ASTM D2487, stabilize the surface prior to placement of the base course(s). Stabilize by mixing ABC or GCA into the underlying course and compacting by approved methods. Consider the stabilized material as part of the underlying course and meet all requirements of the underlying course. Do not allow traffic or other operations to disturb the finished underlying course and maintain in a satisfactory condition until the base course is placed. 3.5 GRADE CONTROL Provide a finished and completed base course conforming to the lines, grades, and cross sections shown. Place line and grade stakes as necessary for control. 3.6 MIXING AND PLACING MATERIALS Mix the coarse and fine aggregates in a stationary plant. Make adjustments in mixing procedures or in equipment, as directed, to obtain true grades, to minimize segregation or degradation, to obtain the required water content, and to insure a satisfactory base course meeting all requirements of this specification. Place the mixed material on the prepared subgrade or subbase in layers of uniform thickness with an approved spreader. Place the layers so that when compacted they will be true to the grades or levels required with the least possible surface disturbance. Where the base course is placed in more than one layer, clean the previously constructed layers of loose and foreign matter by sweeping with power sweepers, power brooms, or hand brooms, as directed. Make adjustments in placing procedures or equipment as may be directed by the Contracting Officer to obtain true grades, to minimize segregation and degradation, to adjust the water content, and to insure an acceptable base course. 3.7 LAYER THICKNESS Compact the completed base course to the thickness indicated. No individual layer may be thicker than 6 inches nor be thinner than 3 inches in compacted thickness. Compact the base course(s) to a total thickness that is within 1/2 inch of the thickness indicated. Where the measured SECTION 32 11 23 Page 8 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% thickness is more than 1/2 inch deficient, correct such areas by scarifying, adding new material of proper gradation, reblading, and recompacting as directed. Where the measured thickness is more than 1/2 inch thicker than indicated, the course will be considered as conforming to the specified thickness requirements. The average job thickness will be the average of all thickness measurements taken for the job and must be within 1/4 inch of the thickness indicated. Measure the total thickness of the base course at intervals of one measurement for each 500 square yards of base course. Measure total thickness using 3 inch diameter test holes penetrating the base course. 3.8 COMPACTION Compact each layer of the base course, as specified, with approved compaction equipment. Maintain water content during the compaction procedure to within plus or minus 3 percent of the optimum water content determined from laboratory tests as specified in this Section. Begin rolling at the outside edge of the surface and proceed to the center, overlapping on successive trips at least one-half the width of the roller. Slightly vary the length of alternate trips of the roller. Adjust speed of the roller as needed so that displacement of the aggregate does not occur. Compact mixture with hand-operated power tampers in all places not accessible to the rollers. Continue compaction until each layer is compacted through the full depth to at least 100 percent of laboratory maximum density. Make such adjustments in compacting or finishing procedures as may be directed by the Contracting Officer to obtain true grades, to minimize segregation and degradation, to reduce or increase water content, and to ensure a satisfactory base course. Remove any materials found to be unsatisfactory and replace with satisfactory material or rework, as directed, to meet the requirements of this specification. 3.9 EDGES OF BASE COURSE Place the base course(s) so that the completed section will be a minimum of 2 feet wider, on all sides, than the next layer that will be placed above it. Place approved material along the outer edges of the base course in sufficient quantity to compact to the thickness of the course being constructed. When the course is being constructed in two or more layers, simultaneously roll and compact at least a 2 foot width of this shoulder material with the rolling and compacting of each layer of the base course, as directed. 3.10 FINISHING Finish the surface of the top layer of base course after final compaction by cutting any overbuild to grade and rolling with a steel-wheeled roller. Do not add thin layers of material to the top layer of base course to meet grade. If the elevation of the top layer of base course is 1/2 inch or more below grade, scarify the top layer to a depth of at least 3 inches and blend new material in and compact to bring to grade. Make adjustments to rolling and finishing procedures as directed by the Contracting Officer to minimize segregation and degradation, obtain grades, maintain moisture content, and insure an acceptable base course. Should the surface become rough, corrugated, uneven in texture, or traffic marked prior to completion, scarify the unsatisfactory portion and rework and recompact it or replace as directed. SECTION 32 11 23 Page 9 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.11 SMOOTHNESS TEST Construct the top layer so that the surface shows no deviations in excess of 3/8 inch when tested with a 12 foot straightedge. Take measurements in successive positions parallel to the centerline of the area to be paved. Also take measurements perpendicular to the centerline at 50 foot intervals. Correct deviations exceeding this amount by removing material and replacing with new material, or by reworking existing material and compacting it to meet these specifications. 3.12 FIELD QUALITY CONTROL 3.12.1 In-Place Tests Perform each of the following tests on samples taken from the placed and compacted ABC and GCA. Take samples and test at the rates indicated. a. Perform density tests on every lift of material placed and at a frequency of one set of tests for every 250 square yards, or portion thereof, of completed area. b. Perform sieve analysis on every lift of material placed and at a frequency of one sieve analysis for every 500 square yards, or portion thereof, of material placed. c. Perform liquid limit and plasticity index tests at the same frequency as the sieve analysis. d. Measure the thickness of the base course at intervals providing at least one measurement for each 500 square yards of base course or part thereof. Measure the thickness using test holes, at least 3 inch in diameter through the base course. 3.12.2 Approval of Material Final approval of the materials will be based on tests for gradation, liquid limit, and plasticity index performed on samples taken from the completed and fully compacted course(s). 3.13 TRAFFIC Completed portions of the base course may be opened to limited traffic, provided there is no marring or distorting of the surface by the traffic. Do not allow heavy equipment on the completed base course except when necessary for construction. When it is necessary for heavy equipment to travel on the completed base course, protect the area against marring or damage to the completed work. 3.14 MAINTENANCE Maintain the base course in a satisfactory condition until the full pavement section is completed and accepted. Immediately repair any defects and repeat repairs as often as necessary to keep the area intact. Retest any base course that was not paved over prior to the onset of winter to verify that it still complies with the requirements of this specification. Rework or replace any area of base course that is damaged as necessary to comply with this specification. SECTION 32 11 23 Page 10 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.15 DISPOSAL OF UNSATISFACTORY MATERIALS Dispose of any unsuitable materials that have been removed outside the limits of Government-controlled land. No additional payments will be made for materials that have to be replaced. -- End of Section -- SECTION 32 11 23 Page 11 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 32 13 13.06 PORTLAND CEMENT CONCRETE PAVEMENT FOR ROADS AND SITE FACILITIES 11/11 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. AMERICAN CONCRETE INSTITUTE (ACI) ACI 211.1 (1991; R 2009) Standard Practice for Selecting Proportions for Normal, Heavyweight and Mass Concrete ACI 301 (2016) Specifications for Structural Concrete ACI 305.1 (2014) Specification for Hot Weather Concreting ACI 306.1 (1990; R 2002) Standard Specification for Cold Weather Concreting ACI 325.12R (2002; R 2013) Guide for Design of Jointed Concrete Pavements for Streets and Local Roads ACI 330R (2008) Guide for the Design and Construction of Concrete Parking Lots AMERICAN WATER WORKS ASSOCIATION (AWWA) AWWA C215 (2016) Extruded Polyolefin Coatings for Steel Water Pipe ASTM INTERNATIONAL (ASTM) ASTM A184/A184M (2017) Standard Specification for Welded Deformed Steel Bar Mats for Concrete Reinforcement ASTM A615/A615M (2016) Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement ASTM A966/A966M (2015) Standard Test Method for Magnetic Particle Examination of Steel Forgings Using Alternating Current ASTM C1077 (2017) Standard Practice for Agencies Testing Concrete and Concrete Aggregates for Use in Construction and Criteria for Testing Agency Evaluation SECTION 32 13 13.06 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% ASTM C1260 (2014) Standard Test Method for Potential Alkali Reactivity of Aggregates (Mortar-Bar Method) ASTM C143/C143M (2015) Standard Test Method for Slump of Hydraulic-Cement Concrete ASTM C150/C150M (2018) Standard Specification for Portland Cement ASTM C1549 (2016) Standard Test Method for Determination of Solar Reflectance Near Ambient Temperature Using a Portable Solar Reflectometer ASTM C1567 (2013) Standard Test Method for Potential Alkali-Silica Reactivity of Combinations of Cementitious Materials and Aggregate (Accelerated Mortar-Bar Method) ASTM C1602/C1602M (2012) Standard Specification for Mixing Water Used in Production of Hydraulic Cement Concrete ASTM C171 (2016) Standard Specification for Sheet Materials for Curing Concrete ASTM C172/C172M (2017) Standard Practice for Sampling Freshly Mixed Concrete ASTM C231/C231M (2017a) Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method ASTM C260/C260M (2010a; R 2016) Standard Specification for Air-Entraining Admixtures for Concrete ASTM C309 (2011) Standard Specification for Liquid Membrane-Forming Compounds for Curing Concrete ASTM C31/C31M (2018b) Standard Practice for Making and Curing Concrete Test Specimens in the Field ASTM C33/C33M (2018) Standard Specification for Concrete Aggregates ASTM C494/C494M (2017) Standard Specification for Chemical Admixtures for Concrete ASTM C618 (2017a) Standard Specification for Coal Fly Ash and Raw or Calcined Natural Pozzolan for Use in Concrete ASTM C78/C78M (2018) Standard Test Method for Flexural Strength of Concrete (Using Simple Beam with Third-Point Loading) SECTION 32 13 13.06 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% ASTM C94/C94M (2017a) Standard Specification for Ready-Mixed Concrete ASTM C989/C989M (2018) Standard Specification for Slag Cement for Use in Concrete and Mortars U.S. DEPARTMENT OF DEFENSE (DOD) UFC 3-250-01 (2016) Pavement Design for Roads and Parking Areas 1.2 DESIGN This materials and construction specification is intended to be used on projects where the design was completed using UFC 3-250-01 Pavement Design for Roads, Streets, Walks, and Open Storage Areas, ACI 330R, Guide for the Design and Construction of Concrete Parking Lots or ACI 325.12R, Guide for Design of Jointed Concrete Pavements for Streets and Local Roads, or equivalent. 1.3 RELATED SECTIONS Portland cement concrete pavement must use Section 32 11 23 AGGREGATE BASE COURSES, in addition to this section. 1.4 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-03 Product Data Curing Materials Admixtures Dowel Reinforcement Submit a complete list of materials including type, brand and applicable reference specifications. Cementitious Materials Aggregate Albedo Provide information identifying the reflectance of the pavement. SD-05 Design Data Concrete Mix Design; G SECTION 32 13 13.06 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Thirty days minimum prior to concrete placement, submit a mix design, with applicable tests, for each strength and type of concrete for approval. Submit a complete list of materials including type; brand; source and amount of cement, fly ash, slag, and admixtures; and applicable reference specifications. Provide mix proportion data using at least three different water-cement ratios for each type of mixture, which will produce a range of strength encompassing those required for each class and type of concrete required. Submittal must clearly indicate where each mix design will be used when more than one mix design is submitted. Obtain acknowledgement of approvals prior to concrete placement. Submit a new mix design for each material source change. SD-06 Test Reports Aggregate Tests Concrete Slump Tests Air Content Tests Flexural Strength Tests Cementitious Materials SD-07 Certificates Ready-mixed Concrete Plant Batch Tickets Cementitious Materials 1.5 DELIVERY, STORAGE, AND HANDLING ASTM C94/C94M. 1.6 QUALITY ASSURANCE 1.6.1 Ready-mixed Concrete Plant Certification Unless otherwise approved by the Contracting Officer, ready mixed concrete must be produced and provided by a National Ready-Mix Concrete Association (NRMCA) certified plant. If a volumetric mobile mixer is used to produce the concrete, rather than ready-mixed concrete, the mixer(s) must conform to the standards of the Volumetric Mixer Manufacturers Bureau (VMMB). Verification must be made by a current VMMB conformance plate affixed to the volumetric mixer equipment. 1.6.2 Contractor Qualifications Unless waived by the Contracting Officer, the Contractor must meet one of the following criteria: a. Contractor must have at least one National Ready Mixed Concrete Association (NRMCA) certified concrete craftsman and at least one American Concrete Institute (ACI) Flatwork Finisher Certified craftsman on site, overseeing each placement crew during all concrete SECTION 32 13 13.06 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% placement. b. Contractor must have no less than three NRMCA certified concrete installers and at least two American Concrete Institute (ACI) Flatwork Finisher Certified installers, who must be on site working as members of each placement crew during all concrete placement. 1.6.3 Required Information Submit copies of laboratory test reports showing that the mix has been successfully tested to produce concrete with the properties specified and that mix will be suitable for the job conditions. The laboratory test reports must include mill test and all other test for cementitious materials, aggregates, and admixtures. Provide maximum nominal aggregate size, combined aggregate gradation analysis, percentage retained and passing sieve, and a graph of percentage retained verses sieve size. Submit test reports along with the concrete mix design. Sampling and testing of materials, concrete mix design, sampling and testing in the field must be performed by a commercial testing laboratory which conforms to ASTM C1077. The laboratory must be approved in writing by the Contracting Officer. 1.6.4 Batch Tickets ASTM C94/C94M. Submit mandatory batch ticket information for each load of ready-mixed concrete. PART 2 PRODUCTS 2.1 MATERIALS 2.1.1 Cementitious Materials Cementitious materials in concrete mix must be 20 to 50 percent non-portland cement pozzolanic materials by weight. Provide test data demonstrating compatibility and performance of concrete satisfactory to Contracting Officer. 2.1.1.1 Cement ASTM C150/C150M, Type I or II III, for high early concrete. 2.1.1.2 Fly Ash and Pozzolan ASTM C618, Type F, or N. Fly ash certificates must include test results in accordance with ASTM C618. 2.1.1.3 Ultra Fine Fly Ash and Ultra Fine Pozzolan Ultra Fine Fly Ash (UFFA) and Ultra Fine Pozzolan (UFP) must conform to ASTM C618, Class F or N, and the following additional requirements: a. The strength activity index at 28 days of age must be at least 95 percent of the control specimens. b. The average particle size must not exceed 6 microns. SECTION 32 13 13.06 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.1.1.4 Slag ASTM C989/C989M, Slag Cement (formerly Ground Granulated Blast Furnace Slag) Grade 100 or 120. Certificates must include test results in accordance with ASTM C989/C989M. 2.1.1.5 Supplementary Cementitious Materials (SCM) Content The concrete mix must always contain one of the SCMs listed in Table 1 within the range specified therein, whether or not the aggregates are found to be reactive in accordance with the paragraph ALKALI REACTIVITY TEST". TABLE 1 SUPPLEMENTARY CEMENTITIOUS MATERIALS CONTENT Supplementary Cementitious Material Minimum Content (percent) Maximum Content (percent) Class N Pozzolan and Class F Fly Ash SiO2 + Al2O3 + Fe2O3 > 70 percent 25 35 SiO2 + A12O3 + Fe2O3 > 80 percent 20 35 SiO2 + A12O3 + Fe2O3 > 90 percent 15 35 UFFA and UFP 7 16 GGBF Slag 40 50 2.1.2 Water Water must conform to ASTM C1602/C1602M. Hot water must not be used unless approved by the Contracting Officer. 2.1.3 Aggregate Coarse aggregate must consist of crushed or uncrushed gravel, crushed stone, or a combination thereof. Aggregates, as delivered to the mixers, must consist of clean, hard, uncoated particles. Coarse aggregate must be washed. Washing must be sufficient to remove dust and other coatings. Fine aggregate must consist of natural sand, manufactured sand, or a combination of the two, and must be composed of clean, hard, durable particles. Both coarse and fine aggregates must meet the requirements of ASTM C33/C33M. 2.1.3.1 Alkali Reactivity Test Aggregates to be used in all concrete in projects over 50,000 SF in size must be evaluated and tested for alkali-aggregate reactivity in accordance with ASTM C1260. The types of aggregates must be evaluated in a combination which matches the proposed mix design (including Class F fly ash or GGBF slag), utilizing ASTM C1567. Test results of the combination must have a measured expansion of less than 0.08 percent at 28 days. Should the test data indicate an expansion of greater than 0.08%, the aggregate(s) must be rejected and new aggregate sources must be submitted SECTION 32 13 13.06 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% for retesting or may submit additional test results incorporating Lithium Nitrate for consideration. ASTM C1567 must be performed as follows to include one of the following options: a. Utilize the low alkali Portland cement and Class F fly ash in combination for the test proportioning. The laboratory must use the Contractor's proposed percentage of cement and fly ash. b. Utilize the low alkali Portland cement and ground granulated blast furnace (GGBF) slag in combination for the test proportioning. The laboratory must use the Contractor's proposed percentage of cement and GGBF. c. Utilize the low alkali Portland cement and Class F fly ash and ground granulated blast furnace (GGBF) slag in combination for the test proportioning. The laboratory must use the Contractor's proposed percentage of cement, fly ash and GGBF. 2.1.3.2 Fine Aggregates ASTM C33/C33M. 2.1.3.3 Coarse Aggregates ASTM C33/C33M. 2.1.4 Admixtures ASTM C494/C494M: Type A, water reducing; Type B, retarding; Type C, accelerating; Type D, water-reducing and retarding; and Type E, water-reducing and accelerating admixture. Do not use calcium chloride admixtures. Where not shown or specified, the use of admixtures is subject to written approval of the Contracting Officer. ASTM C260/C260M: Air-entraining. 2.1.5 Reinforcement 2.1.5.1 Dowel Bars Bars must conform to ASTM A615/A615M, Grade 60 for plain billet-steel bars of the size and length indicated. Remove all burrs and projections from the bars. 2.1.5.2 Coated Dowel Bars Bars must conform to ASTM A615/A615M, Grade 60 for plain billet-steel bars of the size and length indicated. Remove all burrs or projections from the dowel bars. Coating system must conform to AWWA C215, Type 2. Coat the bars with a double coat system or an epoxy coating system for resistance to penetration of oil and salt solutions. The systems must be in accordance with manufacturer's recommendation for coatings which are not bondable to concrete. Bond the coating to the dowel bar to resist laps or folds during movement of the joint. Coating thickness must be 7 mils minimum and 20 mils maximum. SECTION 32 13 13.06 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.1.5.3 Tie Bars Bars must be billet or axle steel deformed bars and conform to ASTM A615/A615M or ASTM A966/A966M Grade 60. 2.1.5.4 Reinforcement Deformed steel bar mats must conform to ASTM A184/A184M. Bar reinforcement must conform to ASTM A615/A615M ASTM A966/A966M, Grade 60. 2.1.6 Curing Materials 2.1.6.1 White-Burlap-Polyethylene Sheet ASTM C171, 0.004 inch thick white opaque polyethylene bonded to 10 oz/linear yard (40 inch) wide burlap. 2.1.6.2 Liquid Membrane-Forming Compound ASTM C309, white pigmented, Type 2, Class B, free of paraffin or petroleum. 2.1.7 Joint Fillers and Sealants Provide as specified in Section 32 01 19 FIELD MOLDED SEALANTS FOR SEALING JOINTS IN RIGID PAVEMENTS. 2.2 CONCRETE PAVEMENT 2.2.1 Joint Layout Drawings If jointing requirements on the project drawings are not compatible with the proposed placement sequence, submit a joint layout plan shop drawing to the Contracting Officer for approval. No work must be allowed to start until the joint layout plan is approved. The joint layout plan must indicate and describe in the detail the proposed jointing plan for contraction joints, expansion joints, and construction joints, in accordance with the following: a. Indicate locations of contraction joints, construction joints, and expansion joints. Spacing between contraction joints must not exceed 15 feet unless noted otherwise or approved by the Contracting Officer. b. The larger dimension of a panel must not be greater than 125% of the smaller dimension. c. The minimum angle between two intersecting joints must be 80 degrees, unless noted otherwise or approved by the Contracting Officer. d. Joints must intersect pavement-free edges at a 90 degree angle the pavement edge and must extend straight for a minimum of 1.5 feet from the pavement edge, where possible. e. Align joints of adjacent panels. f. Align joints in attached curbs with joints in pavement when possible. g. Ensure joint depth, widths, and dimensions are specified. h. Minimum contraction joint depth must be 1/4 of the pavement thickness. SECTION 32 13 13.06 Page 8 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% The minimum joint width must be 1/8 inch. i. Use expansion joints only where pavement abuts buildings, foundations, manholes, and other fixed objects. 2.2.2 Albedo Provide a system with a minimum initial Solar Reflectance of at least 0.33 and a 3-year aged of 0.28 as tested in accordance with ASTM C1549. 2.3 CONTRACTOR-FURNISHED MIX DESIGN Contractor-furnished concrete mix must be designed in accordance with ACI 211.1 except as modified herein, and the mix design must be as specified herein under paragraph SUBMITTALS. The concrete must have a minimum flexural strength of 650 pounds per square inch at 28 days. The concrete may be air entrained. If air entrainment is used the air content must be 6.0. Maximum size aggregate for slip forming must be 1.5 inches. The slump must be one to 3 inches (or less when slip form is used). For slipformed pavement, at the start of the project, select a maximum allowable slump which will produce in-place pavement meeting the specified tolerances for control of edge slump. The selected slump must be applicable to both pilot and fill-in lanes. If the cementitious material is not sufficient to produce concrete of the flexural strength required it must be increased as necessary, without additional compensation under the Contract. The cementitious factor must be calculated using cement, Class F fly ash, and or GGBF slag. The mix must use a SCM material by weight in accordance with Table 1 in "Supplementary Cementitious Materials (SCM) Content" PART 3 EXECUTION 3.1 FORMS 3.1.1 Construction Construct forms to be removable without damaging the concrete. 3.1.2 Coating Before placing the concrete, coat the contact surfaces of forms with a non-staining mineral oil, non-staining form coating compound, biodegradable form release agent, or two coats of nitro-cellulose lacquer. 3.1.3 Grade and Alignment Check and correct grade elevations and alignment of the forms immediately before placing the concrete. 3.2 REINFORCEMENT 3.2.1 Dowel Bars Install bars accurately aligned, vertically and horizontally, at indicated locations and to the dimensions and tolerances indicated. Before installation thoroughly grease the sliding portion of each dowel. Dowels must remain in position during concrete placement and curing. SECTION 32 13 13.06 Page 9 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.2.2 Coated Dowel Bars Install bars, accurately aligned vertically and horizontally, at indicated locations and to the dimensions and tolerances indicated. Reject coatings which are perforated, cracked or otherwise damaged. While handling avoid scuffing or gouging of the coatings. 3.2.3 Tie Bars Install bars, accurately aligned horizontally and vertically, at indicated locations. For slipform construction, insert bent tie bars by hand or other approved means. 3.2.4 Setting Slab Reinforcement Reinforcement must be positioned on suitable chairs prior to concrete placement. At expansion, contraction and construction joints, place the reinforcement as indicated. Reinforcement, when placed in concrete, must be free of mud, oil, scale or other foreign materials. Place reinforcement accurately and wire securely. The laps at splices must be 12 inches minimum and the distances from ends and sides of slabs and joints must be as indicated. 3.3 MEASURING, MIXING, CONVEYING, AND PLACING CONCRETE 3.3.1 Measuring ASTM C94/C94M. 3.3.2 Mixing ASTM C94/C94M, except as modified herein. Begin mixing within 30 minutes after cement has been added to aggregates. When the air temperature is greater than 85 degrees F, place concrete within 60 minutes. With the approval of the Contracting Officer, a hydration stabilizer admixture meeting the requirements of ASTM C494/C494M Type D, may be used to extend the placement time to 90 minutes. Additional water may be added to bring slump within required limits as specified in Section 11.7 of ASTM C94/C94M, provided that the specified water-cement ratio is not exceeded. 3.3.3 Conveying ASTM C94/C94M. 3.3.4 Placing Follow guidance of ACI 301, except as modified herein. Do not exceed a free vertical drop of 5 feet from the point of discharge. Deposit concrete either directly from the transporting equipment or by conveyor on to the pre-wetted subgrade or subbase, unless otherwise specified. Do not place concrete on frozen subgrade or subbase. Deposit the concrete between the forms to an approximately uniform height. Place concrete continuously at a uniform rate, with minimum amount of segregation, without damage to the grade and without unscheduled stops except for equipment failure or other emergencies. If this occurs within 10 feet of a previously placed expansion joint, remove concrete back to joint, repair any damage to grade, install a construction joint and continue placing concrete only after cause of the stop has been corrected. SECTION 32 13 13.06 Page 10 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.3.5 Vibration Immediately after spreading concrete, consolidate concrete with internal type vibrating equipment along the boundaries of all slabs regardless of slab thickness, and interior of all concrete slabs 6 inches or more in thickness. Limit duration of vibration to that necessary to produce consolidation of concrete. Excessive vibration will not be permitted. Vibrators must not be operated in concrete at one location for more than 15 seconds. Vibrating equipment of a type approved by the Contracting Officer may be used to consolidate concrete in unreinforced pavement slabs less than 6 inches thick. 3.3.5.1 Vibrating Equipment Operate equipment, except hand-manipulated equipment, ahead of the finishing machine. Select the number of vibrating units and power of each unit to properly consolidate the concrete. Mount units on a frame that is capable of vertical movement and, when necessary, radial movement, so vibrators may be operated at any desired depth within the slab or be completely withdrawn from the concrete. Clear distance between frame-mounted vibrating units that have spuds that extend into the slab at intervals across the paving lane must not exceed 30 inches. Distance between end of vibrating tube and side form must not exceed 2 inches. For pavements less than 10 inches thick, operate vibrators at mid-depth parallel with or at a slight angle to the subbase. For thicker pavements, angle vibrators toward the vertical, with vibrator tip preferably about 2 inches from subbase, and top of vibrator a few inches below pavement surface. Vibrators may be pneumatic, gas driven, or electric, and must be operated at frequencies within the concrete of not less than 8,000 vibrations per minute. Amplitude of vibration must be such that noticeable vibrations occur at 1.5 foot radius when the vibrator is inserted in the concrete to the depth specified. 3.3.6 Cold Weather Except with authorization, do not place concrete when ambient temperature is below 40 degrees F or when concrete is likely to be subjected to freezing temperatures within 24 hours. When authorized, when concrete is likely to be subjected to freezing within 24 hours after placing, heat concrete materials so that temperature of concrete when deposited is between 65 and 80 degrees F. Methods of heating materials are subject to approval of the Contracting Officer. Do not heat mixing water above 165 degrees F. Remove lumps of frozen material and ice from aggregates before placing aggregates in mixer. Follow practices found in ACI 306.1. 3.3.7 Hot Weather Maintain required concrete temperature in accordance with Figure NRMCA NOMOGRAPH FOR ESTIMATING EVAPORATION RATE ON THE BASIS OF MENZEL FORMULA in ACI 305.1 to prevent evaporation rate from exceeding 0.2 pound of water per square foot of exposed concrete per hour. Cool ingredients before mixing or use other suitable means to control concrete temperature and prevent rapid drying of newly placed concrete. After placement, use fog spray, apply monomolecular film, or use other suitable means to reduce the evaporation rate. Start curing when surface of fresh concrete is sufficiently hard to permit curing without damage. Cool underlying material by sprinkling lightly with water before placing concrete. Follow practices found in ACI 305.1. SECTION 32 13 13.06 Page 11 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.4 PAVING Pavement must be constructed with paving and finishing equipment utilizing fixed forms or slipforms. 3.4.1 Consolidation The paver vibrators must be inserted into the concrete not closer to the underlying material than 2 inches. The vibrators or tamping units in front of the paver must be automatically controlled so that they stop immediately as forward motion ceases. Excessive vibration must not be permitted. Concrete in small, odd-shaped slabs or in locations inaccessible to the paver mounted vibration equipment must be vibrated with a hand-operated immersion vibrator. Vibrators must not be used to transport or spread the concrete. 3.4.2 Operation When the paver is operated between or adjacent to previously constructed pavement (fill-in lanes), provisions must be made to prevent damage to the previously constructed pavement, including keeping the existing pavement surface free of debris, and placing rubber mats beneath the paver tracks. Transversely oscillating screeds and extrusion plates must overlap the existing pavement the minimum possible, but in no case more than 8 inches. 3.4.3 Required Results The paver-finisher must be operated to produce a thoroughly consolidated slab throughout, true to line and grade within specified tolerances. The paver-finishing operation must produce a surface finish free of irregularities, tears, voids of any kind, and other discontinuities. It must produce only a minimum of paste at the surface. Multiple passes of the paver-finisher must not be permitted. The equipment and its operation must produce a finished surface requiring no hand finishing, other than the use of cutting straightedges, except in very infrequent instances. No water, other than true fog sprays (mist), must be applied to the concrete surface during paving and finishing. 3.4.4 Fixed Form Paving Forms must be steel, except that wood forms may be used for curves having a radius of 150 feet or less, and for fillets. Forms may be built up with metal or wood, added only to the base, to provide an increase in depth of not more than 25 percent. The base width of the form must be not less than eight-tenths of the vertical height of the form, except that forms 8 inches or less in vertical height must have a base width not less than the vertical height of the form. Wood forms for curves and fillets must be adequate in strength and rigidly braced. Forms must be set on firm material cut true to grade so that each form section when placed will be firmly in contact with the underlying layer for its entire base. Forms must not be set on blocks or on built-up spots of underlying material. Forms must remain in place at least 12 hours after the concrete has been placed. Forms must be removed without injuring the concrete. 3.4.5 Slipform Paving The slipform paver must shape the concrete to the specified and indicated cross section in one pass, and must finish the surface and edges so that only a very minimum amount of hand finishing is required. Dowels must not SECTION 32 13 13.06 Page 12 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% be installed by dowel inserters attached to the paver or by any other means of inserting the dowels into the plastic concrete. 3.4.6 Placing Reinforcing Steel Reinforcement must be positioned on suitable chairs securely fastened to the subgrade prior to concrete placement. 3.4.7 Placing Dowels and Tie Bars Dowels must be installed with alignment not greater than 1/8 inch per ft. Except as otherwise specified below, location of dowels must be within a horizontal tolerance of plus or minus 5/8 inch and a vertical tolerance of plus or minus 3/16 inch. The portion of each dowel intended to move within the concrete or expansion cap must be painted with one coat of rust inhibiting primer paint, and then oiled just prior to placement. Dowels and tie bars in joints must be omitted when the center of the dowel or tie bar is located within a horizontal distance from an intersecting joint equal to or less than one-fourth of the slab thickness. 3.4.7.1 Contraction Joints Dowels and tie bars in longitudinal and transverse contraction joints within the paving lane must be held securely in place by means of rigid metal basket assemblies. The dowels and tie bars must be welded to the assembly or held firmly by mechanical locking arrangements that will prevent them from becoming distorted during paving operations. The basket assemblies must be held securely in the proper location by means of suitable anchors. 3.4.7.2 Construction Joints-Fixed Form Paving Installation of dowels and tie bars must be by the bonded-in-place method, supported by means of devices fastened to the forms. Installation by removing and replacing in preformed holes will not be permitted. 3.4.7.3 Dowels Installed in Hardened Concrete Installation must be by bonding the dowels into holes drilled into the hardened concrete. Holes approximately 1/8 inch greater in diameter than the dowels must be drilled into the hardened concrete. Dowels must be bonded in the drilled holes using epoxy resin injected at the back of the hole before installing the dowel and extruded to the collar during insertion of the dowel so as to completely fill the void around the dowel. Application by buttering the dowel is not permitted. The dowels must be held in alignment at the collar of the hole, after insertion and before the grout hardens, by means of a suitable metal or plastic collar fitted around the dowel. The vertical alignment of the dowels must be checked by placing the straightedge on the surface of the pavement over the top of the dowel and measuring the vertical distance between the straightedge and the beginning and ending point of the exposed part of the dowel. Where tie bars are required in longitudinal construction joints of slipform pavement, bent tie bars must be installed at the paver, in front of the transverse screed or extrusion plate. If tie bars are required, a standard keyway must be constructed, and the bent tie bars must be inserted into the plastic concrete through a 26 gauge thick metal keyway liner. Tie bars must not be installed in preformed holes. The keyway liner must be protected and must remain in place and become part of the joint. Before placement of the adjoining paving lane, the tie bars must SECTION 32 13 13.06 Page 13 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% be straightened, without spalling the concrete around the bar. 3.4.7.4 Expansion Joints Dowels in expansion joints must be installed by the bonded-in-place method or by bonding into holes drilled in hardened concrete, using procedures specified above. 3.5 FINISHING CONCRETE Start finishing operations immediately after placement of concrete. Use finishing machine, except hand finishing may be used in emergencies and for concrete slabs in inaccessible locations or of such shapes or sizes that machine finishing is impracticable. Finish pavement surface on both sides of a joint to the same grade. Finish formed joints from a securely supported transverse bridge. Provide hand finishing equipment for use at all times. Transverse and longitudinal surface tolerances must not exceed 1/4 inch in 10 feet. 3.5.1 Side Form Finishing Strike off and screed concrete to the required slope and cross-section by a power-driven transverse finishing machine. Transverse rotating tube or pipe is not permitted unless approved by the Contracting Officer. Elevation of concrete must be such that, when consolidated and finished, pavement surface will be adequately consolidated and at the required grade. Equip finishing machine with two screeds which are readily and accurately adjustable for changes in pavement slope and compensation for wear and other causes. Make as many passes over each area of pavement and at such intervals as necessary to give proper compaction, retention of coarse aggregate near the finished surface, and a surface of uniform texture, true to grade and slope. Do not permit excessive operation over an area, which will result in an excess of mortar and water being brought to the surface. 3.5.1.1 Equipment Operation Maintain the travel of machine on the forms without lifting, wobbling, or other variation of the machine which tend to affect the precision of concrete finish. Keep the tops of the forms clean by a device attached to the machine. During the first pass of the finishing machine, maintain a uniform ridge of concrete ahead of the front screed for its entire length. 3.5.1.2 Joint Finish Before concrete is hardened, correct edge slump of pavement, exclusive of edge rounding, in excess of 0.02 foot. Finish concrete surface on each side of construction joints to the same plane, and correct deviations before newly placed concrete has hardened. 3.5.1.3 Hand Finishing Strike-off and screed surface of concrete to elevations slightly above finish grade so that when concrete is consolidated and finished pavement surface is at the indicated elevation. Vibrate entire surface until required compaction and reduction of surface voids is secured with a strike-off template. SECTION 32 13 13.06 Page 14 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.5.1.4 Longitudinal Floating After initial finishing, further smooth and consolidate concrete by means of hand-operated longitudinal floats. Use floats that are not less than 12 feet long and 6 inches wide and stiffened to prevent flexing and warping. 3.5.2 Texturing Before the surface sheen has disappeared and before the concrete hardens, the surface of the pavement must be given a texture as described herein. Following initial texturing on the first day of placement, the Placing Foreman, Contracting Officer representative, and a representative of the Using Agency must inspect the texturing for compliance with design requirements. After curing is complete, all textured surfaces must be thoroughly power broomed to remove all debris. The concrete in areas of recesses for tie-down anchors, lighting fixtures, and other outlets in the pavement must be finished to provide a surface of the same texture as the surrounding area. 3.5.2.1 Burlap Drag Finish Before concrete becomes non-plastic, finish the surface of the slab by dragging on the surface a strip of clean, wet burlap measuring from 3 to 10 feet long and 2 feet wider than the width of the pavement. Select dimension of burlap drag so that at least 3 feet of the material is in contact with the pavement. Drag the surface so as to produce a finished surface with a fine granular or sandy texture without leaving disfiguring marks. 3.5.2.2 Brooming Finish the surface of the slab by brooming the surface with a new wire broom at least 18 inches wide. Gently pull the broom over the surface of the pavement from edge to edge just before the concrete becomes non-plastic. Slightly overlap adjacent strokes of the broom. Broom perpendicular to centerline of pavement so that corrugations produced will be uniform in character and width, and not more than 1/16 inch in depth. Broomed surface must be free from porous spots, irregularities, depressions, and small pockets or rough spots such as may be caused by accidentally disturbing particles of coarse aggregate embedded near the surface. 3.5.3 Edging At the time the concrete has attained a degree of hardness suitable for edging, carefully finish slab edges, including edges at formed joints, with an edge having a maximum radius of 1/8 inch. When brooming is specified for the final surface finish, edge transverse joints before starting brooming, then operate broom to obliterate as much as possible the mark left by the edging tool without disturbing the rounded corner left by the edger. Clean by removing loose fragments and soupy mortar from corners or edges of slabs which have crumbled and areas which lack sufficient mortar for proper finishing. Refill voids solidly with a mixture of suitable proportions and consistency and refinish. Remove unnecessary tool marks and edges. Remaining edges must be smooth and true to line. SECTION 32 13 13.06 Page 15 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.5.4 Repair of Surface Defects Follow guidance of ACI 301. 3.6 CURING AND PROTECTION Protect concrete adequately from injurious action by sun, rain, flowing water, frost, mechanical injury, tire marks and oil stains, and do not allow it to dry out from the time it is placed until the expiration of the minimum curing periods specified herein. Use White-Burlap-Polyethylene Sheet or liquid membrane-forming compound, except as specified otherwise herein. Do not use membrane-forming compound on surfaces where its appearance would be objectionable, on surfaces to be painted, where coverings are to be bonded to concrete, or on concrete to which other concrete is to be bonded. Maintain temperature of air next to concrete above 40 degrees F for the full curing periods. 3.6.1 White-Burlap-Polyethylene Sheet Wet entire exposed surface thoroughly with a fine spray of water, saturate burlap but do not have excessive water dripping off the burlap and then cover concrete with White-Burlap-Polyethylene Sheet, burlap side down. Lay sheets directly on concrete surface and overlap 12 inches. Make sheeting not less than 18 inches wider than concrete surface to be cured, and weight down on the edges and over the transverse laps to form closed joints. Repair or replace sheets when damaged during curing. Check daily to assure burlap has not lost all moisture. If moisture evaporates, resaturate burlap and re-place on pavement (re-saturation and re-placing must take no longer than 10 minutes per sheet). Leave sheeting on concrete surface to be cured for at least 7 days. 3.6.2 Liquid Membrane-Forming Compound Curing Apply compound immediately after surface loses its water sheen and has a dull appearance and before joints are sawed. Agitate curing compound thoroughly by mechanical means during use and apply uniformly in a two-coat continuous operation by suitable power-spraying equipment. Total coverage for the two coats must be at least one gallon of undiluted compound per 200 square feet. Compound must form a uniform, continuous, coherent film that will not check, crack, or peel and must be free from pinholes or other imperfections. Apply an additional coat of compound immediately to areas where film is defective. Respray concrete surfaces that are subject to heavy rainfall within 3 hours after curing compound has been applied in the same manner. 3.6.2.1 Protection of Treated Surfaces Keep concrete surfaces to which liquid membrane-forming compounds have been applied free from vehicular traffic and other sources of abrasion for not less than 72 hours. Foot traffic is allowed after 24 hours for inspection purposes. Maintain continuity of coating for entire curing period and repair damage to coating immediately. 3.6.3 Liquid Chemical Sealer-Hardener Apply sealer-hardener to interior floors not receiving floor covering and floors located under access flooring. Apply the sealer-hardener in accordance with manufacturer's recommendations. Seal or cover joints and openings in which joint sealant is to be applied as required by the joint SECTION 32 13 13.06 Page 16 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% sealant manufacturer. The sealer-hardener must not be applied until the concrete has been moist cured and has aged for a minimum of 30 days. Apply a minimum of two coats of sealer-hardener. 3.7 FIELD QUALITY CONTROL 3.7.1 Sampling The Contractor's approved laboratory must collect samples of fresh concrete in accordance with ASTM C172/C172M during each working day as required to perform tests specified herein. Make test specimens in accordance with ASTM C31/C31M. 3.7.2 Consistency Tests The Contractor's approved laboratory must perform concrete slump tests in accordance with ASTM C143/C143M. Take samples for slump determination from concrete during placement. Perform tests at the beginning of a concrete placement operation and for each batch (minimum) or every 20 cubic yards (maximum) of concrete to ensure that specification requirements are met. In addition, perform tests each time test beams and cylinders are made. 3.7.3 Flexural Strength Tests The Contractor's approved laboratory must test for flexural strength in accordance with ASTM C78/C78M. Make four test specimens for each set of tests. Test two specimens at 14 days, and the other two at 28 days. Concrete strength will be considered satisfactory when the minimum of the 28-day test results equals or exceeds the specified 28-day flexural strength, and no individual strength test is less than 550 pounds per square inch. If the ratio of the 28-day strength test to the specified 28 -day strength is less than 65 percent, make necessary adjustments for conformance. Frequency of flexural tests on concrete beams must be not less than four test beams for each 50 cubic yards of concrete, or fraction thereof, placed. Concrete which is determined to be defective, based on the strength acceptance criteria therein, must be removed and replaced with acceptable concrete. 3.7.4 Air Content Tests Test air-entrained concrete for air content at the same frequency as specified for slump tests. Determine percentage of air in accordance with ASTM C231/C231M on samples taken during placement of concrete in forms. 3.7.5 Surface Testing Surface testing for surface smoothness , edge slump and plan grade must be performed as indicated below by the Testing Laboratory. The measurements must be properly referenced in accordance with paving lane identification and stationing, and a report given to the Contracting Officer within 24 hours after measurement is made. A final report of surface testing, signed by a Registered Engineer, containing all surface measurements and a description of all actions taken to correct deficiencies, must be provided to the Contracting Officer upon conclusion of surface testing. 3.7.5.1 Surface Smoothness Requirements The finished surfaces of the pavements must have no abrupt change of 1/8 SECTION 32 13 13.06 Page 17 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% inch or more, and all pavements must be within the tolerances specified when checked with a 12 foot straightedge: 1/5 inch longitudinal and 1/4 inch transverse directions for roads and streets and 1/4 inch for both directions for other concrete surfaces, such as parking areas. 3.7.5.2 Surface Smoothness Testing Method The surface of the pavement must be tested with the straightedge to identify all surface irregularities exceeding the tolerances specified above. The straightedge must be 12 feet and be constructed of aluminum or other lightweight metal and must have blades of box or box-girder cross section with flat bottom reinforced to ensure rigidity and accuracy. Straightedges must have handles to facilitate movement on pavement. The entire area of the pavement must be tested in both a longitudinal and a transverse direction on parallel lines approximately 15 feet apart. The straightedge must be held in contact with the surface and moved ahead one-half the length of the straightedge for each successive measurement. The amount of surface irregularity must be determined by placing the straightedge on the pavement surface and allowing it to rest upon the two highest spots covered by its length and measuring the maximum gap between the straightedge and the pavement surface, in the area between these two high points. 3.7.6 Plan Grade Testing and Conformance The surfaces must vary not more than 0.06 foot above or below the plan grade line or elevation indicated. Each pavement category must be checked for conformance with plan grade requirements by running lines of levels at intervals to determine the elevation at each joint intersection. 3.7.7 Test for Pavement Thickness At the direction of the Contracting Officer, full depth cores of 4 inch diameter may be required every 2000 square feet of concrete pavement to measure thickness. 3.7.8 Reinforcement Inspect reinforcement prior to installation to assure it is free of loose flaky rust, loose scale, oil, mud, or other objectionable material. 3.7.9 Dowels Inspect dowel placement prior to placing concrete to assure that dowels are of the size indicated, and are spaced, aligned and painted and oiled as specified. Dowels must not deviate from vertical or horizontal alignment after concrete has been placed by more than 1/8 inch per foot. -- End of Section -- SECTION 32 13 13.06 Page 18 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 32 16 19 CONCRETE CURBS, GUTTERS AND SIDEWALKS 05/18 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO) AASHTO M 182 (2005; R 2017) Standard Specification for Burlap Cloth Made from Jute or Kenaf and Cotton Mats ASTM INTERNATIONAL (ASTM) ASTM A1064/A1064M (2017) Standard Specification for Carbon-Steel Wire and Welded Wire Reinforcement, Plain and Deformed, for Concrete ASTM A615/A615M (2016) Standard Specification for Deformed and Plain Carbon-Steel Bars for Concrete Reinforcement ASTM C143/C143M (2015) Standard Test Method for Slump of Hydraulic-Cement Concrete ASTM C171 (2016) Standard Specification for Sheet Materials for Curing Concrete ASTM C172/C172M (2017) Standard Practice for Sampling Freshly Mixed Concrete ASTM C173/C173M (2016) Standard Test Method for Air Content of Freshly Mixed Concrete by the Volumetric Method ASTM C231/C231M (2017a) Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method ASTM C309 (2011) Standard Specification for Liquid Membrane-Forming Compounds for Curing Concrete ASTM C31/C31M (2018) Standard Practice for Making and Curing Concrete Test Specimens in the Field ASTM C920 (2018) Standard Specification for Elastomeric Joint Sealants SECTION 32 16 19 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% ASTM D1751 (2004; E 2013; R 2013) Standard Specification for Preformed Expansion Joint Filler for Concrete Paving and Structural Construction (Nonextruding and Resilient Bituminous Types) ASTM D1752 (2004a; R 2013) Standard Specification for Preformed Sponge Rubber Cork and Recycled PVC Expansion ASTM D5893/D5893M (2016) Standard Specification for Cold Applied, Single Component, Chemically Curing Silicone Joint Sealant for Portland Cement Concrete Pavements INTERNATIONAL CODE COUNCIL (ICC) ICC A117.1 COMM (2017) Standard And Commentary Accessible and Usable Buildings and Facilities 1.2 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-03 Product Data Concrete SD-06 Test Reports Field Quality Control 1.3 EQUIPMENT, TOOLS, AND MACHINES 1.3.1 General Requirements Plant, equipment, machines, and tools used in the work will be subject to approval and must be maintained in a satisfactory working condition at all times. Use equipment capable of producing the required product, meeting grade controls, thickness control and smoothness requirements as specified. Discontinue using equipment that produces unsatisfactory results. Allow the Contracting Officer access at all times to the plant and equipment to ensure proper operation and compliance with specifications. 1.3.2 Slip Form Equipment Slip form paver or curb forming machines, will be approved based on trial use on the job and must be self-propelled, automatically controlled, crawler mounted, and capable of spreading, consolidating, and shaping the plastic concrete to the desired cross section in one pass. SECTION 32 16 19 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.4 ENVIRONMENTAL REQUIREMENTS 1.4.1 Placing During Cold Weather Do not place concrete when the air temperature reaches 40 degrees F and is falling, or is already below that point. Placement may begin when the air temperature reaches 35 degrees F and is rising, or is already above 40 degrees F. Make provisions to protect the concrete from freezing during the specified curing period. If necessary to place concrete when the temperature of the air, aggregates, or water is below 35 degrees F, placement and protection must be approved in writing. Approval will be contingent upon full conformance with the following provisions. Prepare and protect the underlying material so that it is entirely free of frost when the concrete is deposited. Heat mixing water and aggregates as necessary to result in the temperature of the in-place concrete being between 50 and 85 degrees F. Methods and equipment for heating must be approved. Use only aggregates that are free of ice, snow, and frozen lumps before entering the mixer. Provide covering or other means as needed to maintain the concrete at a temperature of at least 50 degrees F for not less than 72 hours after placing, and at a temperature above freezing for the remainder of the curing period. 1.4.2 Placing During Warm Weather The temperature of the concrete as placed must not exceed 85 degrees F except where an approved retarder is used. Cool the mixing water and aggregates as necessary to maintain a satisfactory placing temperature. The placing temperature must not exceed 95 degrees F at any time. PART 2 PRODUCTS 2.1 CONCRETE Provide concrete conforming to the applicable requirements of Section 03 30 00 CAST-IN-PLACE CONCRETE except as otherwise specified. Concrete must have a minimum compressive strength of 3500 psi at 28 days. Size of aggregate must not exceed 1-1/2 inches. Submit copies of certified delivery tickets for all concrete used in the construction. 2.1.1 Air Content Use concrete mixtures that have an air content by volume of concrete of 5 to 7 percent, based on measurements made immediately after discharge from the mixer. 2.1.2 Slump Use concrete with a slump of 3 inches plus or minus 1 inch for hand placed concrete or 1 inch plus or minus 1/2 inch for slipformed concrete as determined in accordance with ASTM C143/C143M. 2.1.3 Reinforcement Steel Use reinforcement bars conforming to ASTM A615/A615M. Use wire mesh reinforcement conforming to ASTM A1064/A1064M. SECTION 32 16 19 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.2 CONCRETE CURING MATERIALS 2.2.1 Impervious Sheet Materials Use impervious sheet materials conforming to ASTM C171, type optional, except that polyethylene film, if used, must be white opaque. 2.2.2 Burlap Use burlap conforming to AASHTO M 182. 2.2.3 White Pigmented Membrane-Forming Curing Compound Use white pigmented membrane-forming curing compound conforming to ASTM C309, Type 2. 2.3 CONCRETE PROTECTION MATERIALS Use concrete protection materials consisting of a linseed oil mixture of equal parts, by volume, of linseed oil and either mineral spirits, naphtha, or turpentine. At the option of the Contractor, commercially prepared linseed oil mixtures, formulated specifically for application to concrete to provide protection against the action of deicing chemicals may be used, except that emulsified mixtures are not acceptable. 2.4 JOINT FILLER STRIPS 2.4.1 Contraction Joint Filler for Curb and Gutter Use hard-pressed fiberboard contraction joint filler for curb and gutter. 2.4.2 Expansion Joint Filler, Premolded Onless otherwise indicated, use 1/2 inch thick premolded expansion joint filler conforming to ASTM D1751 or ASTM D1752. 2.5 JOINT SEALANTS Use cold-applied joint sealant conforming to ASTM C920 or ASTM D5893/D5893M. 2.6 FORM WORK Design and construct form work to ensure that the finished concrete will conform accurately to the indicated dimensions, lines, and elevations, and within the tolerances specified. Use wood or steel forms that are straight and of sufficient strength to resist springing during depositing and consolidating concrete. 2.6.1 Wood Forms Use forms that are surfaced plank, 2 inches nominal thickness, straight and free from warp, twist, loose knots, splits or other defects. Use forms with a nominal length of 10 feet. Radius bends may be formed with 3/4 inch boards, laminated to the required thickness. 2.6.2 Steel Forms Use channel-formed sections with a flat top surface and welded braces at each end and at not less than two intermediate points. Use forms with SECTION 32 16 19 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% interlocking and self-aligning ends. Provide flexible forms for radius forming, corner forms, form spreaders, and fillers as needed. Use forms with a nominal length of 10 feet and that have a minimum of 3 welded stake pockets per form. Use stake pins consisting of solid steel rods with chamfered heads and pointed tips designed for use with steel forms. 2.6.3 Sidewalk Forms Use sidewalk forms that are of a height equal to the full depth of the finished sidewalk. 2.6.4 Curb and Gutter Forms Use curb and gutter outside forms that have a height equal to the full depth of the curb or gutter. Use rigid forms for curb returns, except that benders or thin plank forms may be used for curb or curb returns with a radius of 10 feet or more, where grade changes occur in the return, or where the central angle is such that a rigid form with a central angle of 90 degrees cannot be used. Back forms for curb returns may be made of 1-1/2 inch benders, for the full height of the curb, cleated together. In lieu of inside forms for curbs, a curb "mule" may be used for forming and finishing this surface, provided the results are approved. 2.6.5 Biodegradable Form Release Agent Use form release agent that is colorless and biodegradableand that is composed of at least 87 percent biobased material. Provide product that does not bond with, stain, or adversely affect concrete surfaces and does not impair subsequent treatments of concrete surfaces. Provide form release agent that does not contain diesel fuel, petroleum-based lubricating oils, waxes, or kerosene. 2.7 Detectable Warning System Detectable Warning Systems shown on the Contract plans are to meet requirements of ICC A117.1 COMM - Section 705. PART 3 EXECUTION 3.1 SUBGRADE PREPARATION Construct subgrade to the specified grade and cross section prior to concrete placement. 3.1.1 Sidewalk Subgrade Place and compact the subgrade in accordance with Section 31 00 00 EARTHWORK. Test the subgrade for grade and cross section with a template extending the full width of the sidewalk and supported between side forms. 3.1.2 Curb and Gutter Subgrade Place and compact the subgrade in accordance with Section 31 00 00 EARTHWORK. Test the subgrade for grade and cross section by means of a template extending the full width of the curb and gutter. Use subgrade materials equal in bearing quality to the subgrade under the adjacent pavement. SECTION 32 16 19 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.1.3 Maintenance of Subgrade Maintain subgrade in a smooth, compacted condition in conformity with the required section and established grade until the concrete is placed. The subgrade must be in a moist condition when concrete is placed. Prepare and protect subgrade so that it is free from frost when the concrete is deposited. 3.2 FORM SETTING Set forms to the indicated alignment, grade and dimensions. Hold forms rigidly in place by a minimum of 3 stakes per form placed at intervals not to exceed 4 feet. Use additional stakes and braces at corners, deep sections, and radius bends, as required. Use clamps, spreaders, and braces where required to ensure rigidity in the forms. Remove forms in a manner that will not injure the concrete. Do not use bars or heavy tools against the concrete when removing the forms. Promptly and satisfactorily repair concrete found to be defective after form removal. Clean forms and coat with form oil or biodegradable form release agent each time before concrete is placed. Wood forms may, instead, be thoroughly wetted with water before concrete is placed, except that with probable freezing temperatures, oiling is mandatory. 3.2.1 Sidewalks Set forms for sidewalks with the upper edge true to line and grade with an allowable tolerance of 1/8 inch in any 10 foot long section. After forms are set, grade and alignment must be checked with a 10 foot straightedge. Sidewalks must have a transverse slope of 1/4 inch per foot Do not remove side forms less than 12 hours after finishing has been completed. 3.2.2 Curbs and Gutters Remove forms used along the front of the curb not less than 2 hours nor more than 6 hours after the concrete has been placed. Do not remove forms used along the back of curb until the face and top of the curb have been finished, as specified for concrete finishing. Do not remove gutter forms while the concrete is sufficiently plastic to slump in any direction. 3.3 SIDEWALK CONCRETE PLACEMENT AND FINISHING 3.3.1 Formed Sidewalks Place concrete in the forms in one layer. When consolidated and finished, the sidewalks must be of the thickness indicated. Use a strike-off guided by side forms after concrete has been placed in the forms to bring the surface to proper section to be compacted. Consolidate concrete by tamping and spading or with an approved vibrator. Finish the surface to grade with a strike off. 3.3.2 Concrete Finishing After straightedging, when most of the water sheen has disappeared, and just before the concrete hardens, finish the surface with a wood or magnesium float or darby to a smooth and uniformly fine granular or sandy texture free of waves, irregularities, or tool marks. Produce a scored surface by brooming with a fiber-bristle brush in a direction transverse to that of the traffic, followed by edging. SECTION 32 16 19 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.3.3 Edge and Joint Finishing Finish all slab edges, including those at formed joints, with an edger having a radius of 1/8 inch. Edge transverse joints before brooming. Eliminate the flat surface left by the surface face of the edger with brooming. Clean and solidly fill corners and edges which have crumbled and areas which lack sufficient mortar for proper finishing with a properly proportioned mortar mixture and then finish. 3.3.4 Surface and Thickness Tolerances Finished surfaces must not vary more than 5/16 inch from the testing edge of a 10-foot straightedge. Permissible deficiency in section thickness will be up to 1/4 inch. 3.4 CURB AND GUTTER CONCRETE PLACEMENT AND FINISHING 3.4.1 Formed Curb and Gutter Place concrete to the required section in a single lift. Consolidate concrete using approved mechanical vibrators. Curve shaped gutters must be finished with a standard curb "mule". 3.4.2 Curb and Gutter Finishing Approved slipformed curb and gutter machines may be used in lieu of hand placement. 3.4.3 Concrete Finishing Float and finish exposed surfaces with a smooth wood float until true to grade and section and uniform in texture. Brush floated surfaces with a fine-hair brush using longitudinal strokes. Round the edges of the gutter and top of the curb with an edging tool to a radius of 1/2 inch. Immediately after removing the front curb form, rub the face of the curb with a wood or concrete rubbing block and water until blemishes, form marks, and tool marks have been removed. Brush the front curb surface, while still wet, in the same manner as the gutter and curb top. Finish the top surface of gutter and entrance to grade with a wood float. 3.4.4 Joint Finishing Finish curb edges at formed joints as indicated. 3.4.5 Surface and Thickness Tolerances Finished surfaces must not vary more than 1/4 inch from the testing edge of a 10-foot straightedge. Permissible deficiency in section thickness will be up to 1/4 inch. 3.5 SIDEWALK JOINTS Construct sidewalk joints to divide the surface into rectangular areas. Space transverse contraction joints at a distance equal to the sidewalk width or 5 feet on centers, whichever is less, and continuous across the slab. Construct longitudinal contraction joints along the centerline of all sidewalks 10 feet or more in width. Construct transverse expansion joints at sidewalk returns and opposite expansion joints in adjoining curbs. Where the sidewalk is not in contact with the curb, install SECTION 32 16 19 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% transverse expansion joints as indicated. Form expansion joints around structures and features which project through or into the sidewalk pavement, using joint filler of the type, thickness, and width indicated. Expansion joints are not required between sidewalks and curb that abut the sidewalk longitudinally. 3.5.1 Sidewalk Contraction Joints Form contraction joints in the fresh concrete by cutting a groove in the top portion of the slab to a depth of at least one-fourth of the sidewalk slab thickness. Unless otherwise approved or indicated, either use a jointer to cut the groove or saw a groove in the hardened concrete with a power-driven saw. Construct sawed joints by sawing a groove in the concrete with a 1/8 inch blade. Provide an ample supply of saw blades on the jobsite before concrete placement is started. Provide at least one standby sawing unit in good working order at the jobsite at all times during the sawing operations. 3.5.2 Sidewalk Expansion Joints Form expansion joints using 1/2 inch joint filler strips. Joint filler in expansion joints surrounding structures and features within the sidewalk may consist of preformed filler material conforming to ASTM D1752 or building paper. Hold joint filler in place with steel pins or other devices to prevent warping of the filler during floating and finishing. Immediately after finishing operations are completed, round joint edges using an edging tool having a radius of 1/8 inch. Remove any concrete over the joint filler. At the end of the curing period, clean the top of expansion joints and fill with cold-applied joint sealant. Use joint sealant that is gray or stone in color. Thoroughly clean the joint opening before the sealing material is placed. Do not spill sealing material on exposed surfaces of the concrete. Apply joint sealing material only when the concrete at the joint is surface dry and atmospheric and concrete temperatures are above 50 degrees F. Immediately remove any excess material on exposed surfaces of the concrete and clean the concrete surfaces. 3.5.3 Reinforcement Steel Placement Accurately and securely fasten reinforcement steel in place with suitable supports and ties before the concrete is placed. 3.6 CURB AND GUTTER JOINTS Construct curb and gutter joints at right angles to the line of curb and gutter. 3.6.1 Contraction Joints Construct contraction joints directly opposite contraction joints in abutting portland cement concrete pavements and spaced so that monolithic sections between curb returns will not be less than 5 feet nor greater than 15 feet in length. a. Construct contraction joints (except for slip forming) by means of 1/8 inch thick separators and of a section conforming to the cross section of the curb and gutter. Remove separators as soon as practicable after concrete has set sufficiently to preserve the width and shape of the joint and prior to finishing. SECTION 32 16 19 Page 8 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% b. When slip forming is used, cut the contraction joints in the top portion of the gutter/curb hardened concrete in a continuous cut across the curb and gutter, using a power-driven saw. Cut the contraction joint to a depth of at least one-fourth of the gutter/curb depth using a 1/8 inch saw blade. 3.6.2 Expansion Joints Form expansion joints by means of preformed expansion joint filler material cut and shaped to the cross section of curb and gutter. Construct expansion joints in curb and gutter directly opposite expansion joints of abutting portland cement concrete pavement using the same type and thickness of joints as joints in the pavement. Where curb and gutter do not abut portland cement concrete pavement, provide expansion joints at least 1/2 inch in width at intervals not less than 30 feet nor greater than 120 feet. Seal expansion joints immediately following curing of the concrete or as soon thereafter as weather conditions permit. Seal expansion joints and the top 1 inch depth of curb and gutter contraction-joints with joint sealant. Thoroughly clean the joint opening before the sealing material is placed. Do not spill sealing material on exposed surfaces of the concrete. Concrete at the joint must be surface dry and atmospheric and concrete temperatures must be above 50 degrees F at the time of application of joint sealing material. Immediately remove excess material on exposed surfaces of the concrete and clean concrete surfaces. 3.7 CURING AND PROTECTION 3.7.1 General Requirements Protect concrete against loss of moisture and rapid temperature changes for at least 7 days from the beginning of the curing operation. Protect unhardened concrete from rain and flowing water. All equipment needed for adequate curing and protection of the concrete must be on hand and ready for use before actual concrete placement begins. Protect concrete as necessary to prevent cracking of the pavement due to temperature changes during the curing period. 3.7.1.1 Mat Method Cover the entire exposed surface with two or more layers of burlap. Overlap mats at least 6 inches. Thoroughly wet the mat with water prior to placing on concrete surface and keep the mat continuously in a saturated condition and in intimate contact with concrete for not less than 7 days. 3.7.1.2 Impervious Sheeting Method Wet the entire exposed surface with a fine spray of water and then cover with impervious sheeting material. Lay sheets directly on the concrete surface with the light-colored side up and overlapped 12 inches when a continuous sheet is not used. Use sheeting that is not less than 18-inches wider than the concrete surface to be cured. Secure sheeting using heavy wood planks or a bank of moist earth placed along edges and laps in the sheets. Satisfactorily repair or replace sheets that are torn or otherwise damaged during curing. Sheeting must remain on the concrete surface to be cured for not less than 7 days. SECTION 32 16 19 Page 9 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.7.1.3 Membrane Curing Method Apply a uniform coating of white-pigmented membrane-curing compound to the entire exposed surface of the concrete as soon after finishing as the free water has disappeared from the finished surface. Coat formed surfaces immediately after the forms are removed and in no case longer than 1 hour after the removal of forms. Do not allow concrete surface to dry before application of the membrane. If drying has occurred, moisten the surface of the concrete with a fine spray of water and apply the curing compound as soon as the free water disappears. Apply curing compound in two coats by hand-operated pressure sprayers at a coverage of approximately 200 square feet/gallon for the total of both coats. Apply the second coat in a direction approximately at right angles to the direction of application of the first coat. The compound must form a uniform, continuous, coherent film that will not check, crack, or peel and must be free from pinholes or other imperfections. If pinholes, abrasion, or other discontinuities exist, apply an additional coat to the affected areas within 30 minutes. Respray concrete surfaces that are subjected to heavy rainfall within 3 hours after the curing compound has been applied by the method and at the coverage specified above. Respray areas where the curing compound is damaged by subsequent construction operations within the curing period. Take precautions necessary to ensure that the concrete is properly cured at sawed joints, and that no curing compound enters the joints. Tightly seal the top of the joint opening and the joint groove at exposed edges before the concrete in the region of the joint is resprayed with curing compound. Use a method used for sealing the joint groove that prevents loss of moisture from the joint during the entire specified curing period. Provide approved standby facilities for curing concrete pavement at a location accessible to the jobsite for use in the event of mechanical failure of the spraying equipment or other conditions that might prevent correct application of the membrane-curing compound at the proper time. Adequately protect concrete surfaces to which membrane-curing compounds have been applied during the entire curing period from pedestrian and vehicular traffic, except as required for joint-sawing operations and surface tests, and from other possible damage to the continuity of the membrane. 3.7.2 Backfilling After curing, remove debris and backfill, grade, and compact the area adjoining the concrete to conform to the surrounding area in accordance with lines and grades indicated. 3.7.3 Protection Protect completed concrete from damage until accepted. Repair damaged concrete and clean concrete discolored during construction. Remove and reconstruct concrete that is damaged for the entire length between regularly scheduled joints. Refinishing the damaged portion will not be acceptable. Dispose of removed material as directed. 3.7.4 Protective Coating Apply a protective coating of linseed oil mixture to the exposed-to-view concrete surface after the curing period, if concrete will be exposed to de-icing chemicals within 6 weeks after placement. Moist cure concrete to receive a protective coating. SECTION 32 16 19 Page 10 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.7.4.1 Application Complete curing and backfilling operation prior to applying two coats of protective coating. Concrete must be surface dry and clean before each application. Spray apply at a rate of not more than 50 square yards/gallon for first application and not more than 70 square yards/gallon for second application, except that the number of applications and coverage for each application for commercially prepared mixture must be in accordance with the manufacturer's instructions. Protect coated surfaces from vehicular and pedestrian traffic until dry. 3.7.4.2 Precautions Do not heat protective coating by direct application of flame or electrical heaters and protect the coating from exposure to open flame, sparks, and fire adjacent to open containers or applicators. Do not apply material at ambient or material temperatures lower than 50 degrees F. 3.8 FIELD QUALITY CONTROL Submit copies of all test reports within 24 hours of completion of the test. 3.8.1 General Requirements Perform the inspection and tests described and meet the specified requirements for inspection details and frequency of testing. Based upon the results of these inspections and tests, take the action and submit reports as required below, and additional tests to ensure that the requirements of these specifications are met. 3.8.2 Concrete Testing 3.8.2.1 Strength Testing Take concrete samples in accordance with ASTM C172/C172M not less than once a day nor less than once for every 250 cubic yards of concrete placed. Mold cylinders in accordance with ASTM C31/C31M for strength testing by an approved laboratory. Each strength test result must be the average of 2 test cylinders from the same concrete sample tested at 28 days, unless otherwise specified or approved. Concrete specified on the basis of compressive strength will be considered satisfactory if the averages of all sets of three consecutive strength test results equal or exceed the specified strength, and no individual strength test result falls below the specified strength by more than 500 psi. 3.8.2.2 Air Content Determine air content in accordance with ASTM C173/C173M or ASTM C231/C231M. Use ASTM C231/C231M with concretes and mortars made with relatively dense natural aggregates. Make two tests for air content on randomly selected batches of each class of concrete placed during each shift. Make additional tests when excessive variation in concrete workability is reported by the placing foreman or the Government inspector. Notify the placing forman if results are out of tolerance. The placing foreman must take appropriate action to have the air content corrected at the plant. Additional tests for air content will be performed on each truckload of material until such time as the air content is within the tolerance specified. SECTION 32 16 19 Page 11 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.8.2.3 Slump Test Perform two slump tests on randomly selected batches of each class of concrete for every 250 cubic yards, or fraction thereof, of concrete placed during each shift. Perform additional tests when excessive variation in the workability of the concrete is noted or when excessive crumbling or slumping is noted along the edges of slip-formed concrete. 3.8.3 Thickness Evaluation Determine the anticipated thickness of the concrete prior to placement by passing a template through the formed section or by measuring the depth of opening of the extrusion template of the curb forming machine. If a slip form paver is used for sidewalk placement, construct the subgrade true to grade prior to concrete placement. The thickness will be determined by measuring each edge of the completed slab. 3.8.4 Surface Evaluation Provide finished surfaces for each category of the completed work that are uniform in color and free of blemishes and form or tool marks. 3.9 SURFACE DEFICIENCIES AND CORRECTIONS 3.9.1 Thickness Deficiency When measurements indicate that the completed concrete section is deficient in thickness by more than 1/4 inch the deficient section will be removed, between regularly scheduled joints, and replaced. 3.9.2 High Areas In areas not meeting surface smoothness and plan grade requirements, reduce high areas either by rubbing the freshly finished concrete with carborundum brick and water when the concrete is less than 36 hours old or by grinding the hardened concrete with an approved surface grinding machine after the concrete is 36 hours old or more. The area corrected by grinding the surface of the hardened concrete must not exceed 5 percent of the area of any integral slab, and the depth of grinding must not exceed 1/4 inch. Remove and replace pavement areas requiring grade or surface smoothness corrections in excess of the limits specified. 3.9.3 Appearance Exposed surfaces of the finished work will be inspected by the Contracting Officer and deficiencies in appearance will be identified. Remove and replace areas which exhibit excessive cracking, discoloration, form marks, or tool marks or which are otherwise inconsistent with the overall appearances of the work. 3.10 DETECTABLE WARNING SYSTEM Install Detectable Warning Systems required by Contract plans in accordance with ICC A117.1 COMM, Section 705, and by manufacturers' installation instructions. -- End of Section -- SECTION 32 16 19 Page 12 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 32 17 23 PAVEMENT MARKINGS 08/16 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to in the text by the basic designation only. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO) AASHTO M 247 (2013) Standard Specification for Glass Beads Used in Pavement Markings AASHTO M 248 (1991; R 2012) Standard Specification for Ready-Mixed White and Yellow Traffic Paints AASHTO M 249 (2012; R2016) Standard Specification for White and Yellow Reflective Thermoplastic Striping Material (Solid Form) ASTM INTERNATIONAL (ASTM) ASTM D1652 (2011; E 2012) Standard Test Method for Epoxy Content of Epoxy Resins ASTM D2074 (2007; R2013) Standard Test Methods for Total, Primary, Secondary, and Tertiary Amine Values of Fatty Amines by Alternative Indicator Method ASTM D2240 (2015; E 2017) Standard Test Method for Rubber Property - Durometer Hardness ASTM D2621 (1987; R 2016) Standard Test Method for Infrared Identification of Vehicle Solids from Solvent-Reducible Paints ASTM D2697 (2003; R 2014) Volume Nonvolatile Matter in Clear or Pigmented Coatings ASTM D3335 (1985a; R 2014) Low Concentrations of Lead, Cadmium, and Cobalt in Paint by Atomic Absorption Spectroscopy ASTM D3718 (1985a; R 2015) Low Concentrations of Chromium in Paint by Atomic Absorption Spectroscopy ASTM D3924 (2016) Standard Specification for Environment for Conditioning and Testing Paint, Varnish, Lacquer, and Related Materials SECTION 32 17 23 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% ASTM D3960 (2005; R 2013) Determining Volatile Organic Compound (VOC) Content of Paints and Related Coatings ASTM D4060 (2014) Abrasion Resistance of Organic Coatings by the Taber Abraser ASTM D4541 (2017) Standard Test Method for Pull-Off Strength of Coatings Using Portable Adhesion Testers ASTM D471 (2016a) Standard Test Method for Rubber Property - Effect of Liquids ASTM D476 (2015) Dry Pigmentary Titanium Dioxide Pigments ASTM D522/D522M (2014) Mandrel Bend Test of Attached Organic Coatings ASTM D638 (2014) Standard Test Method for Tensile Properties of Plastics ASTM D6628 (2003; R 2015) Standard Specification for Color of Pavement Marking Materials ASTM D695 (2010) Standard Test Method for Compressive Properties of Rigid Plastics ASTM D711 (2010; R 2015) No-Pick-Up Time of Traffic Paint ASTM D7234 (2012) Standard Test Method for Pull-Off Adhesion Strength of Coatings on Concrete Using Portable Pull-Off Adhesion Testers ASTM D823 (2018) Standard Practices for Producing Films of Uniform Thickness of Paint, Varnish, and Related Products on Test Panels. ASTM E1347 (2006; R 2011) Color and Color Difference Measurement by Tristimulus (Filter) Colorimetry ASTM G154 (2016) Standard Practice for Operating Fluorescent Light Apparatus for UV Exposure of Nonmetallic Materials INTERNATIONAL CONCRETE REPAIR INSTITUTE (ICRI) ICRI 03732 (1997) Selecting and Specifying Concrete Surface Preparation for Sealers, Coatings, and Polymer Overlays U.S. FEDERAL AVIATION ADMINISTRATION (FAA) FAA AC 150/5370-10 (2014; Rev G; Errata 1 2015; Errata 2 2016) Standards for Specifying SECTION 32 17 23 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Construction of Airports U.S. FEDERAL HIGHWAY ADMINISTRATION (FHWA) MUTCD (2015) Manual on Uniform Traffic Control Devices U.S. GENERAL SERVICES ADMINISTRATION (GSA) FED-STD-595 (Rev C; Notice 1) Colors Used in Government Procurement FS TT-B-1325 (Rev D; Notice 1; Notice 2 2017) Beads (Glass Spheres) Retro-Reflective (Metric) FS TT-P-1952 (2015; Rev F) Paint, Traffic and Airfield Markings, Waterborne 1.2 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only or as otherwise designated. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-03 Product Data Surface Preparation Equipment List Application Equipment List Safety Data Sheets SD-07 Certificates Qualifications Volatile Organic Compound 1.3 QUALITY ASSURANCE 1.3.1 Regulatory Requirements Submit certificate stating that the proposed pavement marking paint meets the Volatile Organic Compound, (VOC) regulations of the local Air Pollution Control District having jurisdiction over the geographical area in which the project is located. Submit Safety Data Sheets for each product. 1.3.2 Qualifications Submit documentation certifying that pertinent personnel are qualified for equipment operation and handling of applicable chemicals. The documentation should include experience on five projects of similar size and scope with references for all personnel. SECTION 32 17 23 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.4 DELIVERY AND STORAGE Deliver paint materials, thermoplastic compound materials, and reflective media in original sealed containers that plainly show the designated name, specification number, batch number, color, date of manufacture, manufacturer's directions, and name of manufacturer. Provide storage facilities at the job site, only in areas approved by the Contracting Officer, for maintaining materials at temperatures recommended by the manufacturer. Make available paint stored at the project site or segregated at the source for sampling not less than 30 days prior to date of required approval for use to allow sufficient time for testing. Notify the Contracting Officer when paint is available for sampling. 1.5 PROJECT/SITE CONDITIONS 1.5.1 Environmental Requirements 1.5.1.1 Weather Limitations for Application Apply pavement markings to clean, dry surfaces, and unless otherwise approved, only when the air and pavement surface temperature is at least 5 degrees F above the dew point and the air and pavement temperatures are within the limits recommended by the pavement marking manufacturer. Allow pavement surfaces to dry after water has been used for cleaning or rainfall has occurred prior to striping or marking. Test the pavement surface for moisture before beginning work each day and after cleaning. Do not commence marking until the pavement is sufficiently dry and the pavement condition has been approved by the Contracting Officer. Employ the "plastic wrap method" to test the pavement for moisture as specified in paragraph TESTING FOR MOISTURE. 1.5.1.2 Weather Limitations for Removal of Pavement Markings on Roads and Parking Areas Pavement surface must be free of snow, ice, or slush; with a surface temperature of at least 40 degrees F and rising at the beginning of operations, except those involving shot or sand blasting or grinding. Cease operation during thunderstorms, or during rainfall, except for waterblasting and removal of previously applied chemicals. Cease waterblasting where surface water accumulation alters the effectiveness of material removal. 1.5.2 Traffic Controls Place warning signs conforming to MUTCD near the beginning of the worksite and well ahead of the worksite for alerting approaching traffic from both directions. Place small markers along newly painted lines or freshly placed raised markers to control traffic and prevent damage to newly painted surfaces or displacement of raised pavement markers. Mark painting equipment with large warning signs indicating slow-moving painting equipment in operation. When traffic must be rerouted or controlled to accomplish the work, provide necessary warning signs, flag persons, and related equipment for the safe passage of vehicles. SECTION 32 17 23 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.5.3 Lighting When night operations are necessary, provide all necessary lighting and equipment. The Government reserves the right to accept or reject night work on the day following night activities by the Contractor. PART 2 PRODUCTS 2.1 EQUIPMENT 2.1.1 Surface Preparation Equipment for Roads and Parking Areas Submit a surface preparation equipment list by serial number, type, model, and manufacturer. Include descriptive data indicating area of coverage per pass, pressure adjustment range, tank and flow capacities, and safety precautions required for the equipment operation. Mobile equipment must allow for removal of markings without damaging the pavement surface or joint sealant. Maintain machines, tools, and equipment used in the performance of the work in satisfactory operating condition. 2.1.1.1 Sandblasting Equipment Use mobile sandblasting equipment capable of producing a pressurized stream of sand and air that effectively removes paint from the surface without filling voids with debris in asphalt or tar pavements or removing joint sealants in portland cement concrete pavements. Include with the equipment and air compressor, hoses, and nozzles of adequate size and capacity for removing paint. Equip the compressor with traps and coalescing filters that maintain the compressed air free of oil and water. 2.1.1.2 Waterblasting Equipment Use mobile waterblasting equipment capable of producing a pressurized stream of water that effectively removes paint from the pavement surface without significantly damaging the pavement. Provide equipment, tools, and machinery which are safe and in good working order at all times. 2.1.1.3 Shotblasting Equipment Use mobile self propelled shotblasting equipment capable of producing an adjustable depth of paint removal and of propelling abrasive particles at high velocities on the paint for effective removal. Ensure each unit is self cleaning and self contained. Use equipment able to confine the abrasive, any dust that is produced, and removed paint and is capable of recycling the abrasive for reuse. 2.1.1.4 Grinding or Scarifying Equipment Use equipment capable of removing surface contaminates, paint build-up, or extraneous markings from the pavement surface without leaving any residue. Clean the surface by hydro blast to remove surface contaminates and ash after a weed torch is used to remove paint. 2.1.1.5 Chemical Removal Equipment Use chemical equipment capable of applying and removing chemicals and paint from the pavement surface, leaving only non-toxic biodegradable residue without scarring or other damage to the pavement or joints and joint seals. SECTION 32 17 23 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.1.2 Application Equipment Submit application equipment list appropriate for the material(s) to be used. Include manufacturer's descriptive data and certification for the planned use that indicates area of coverage per pass, pressure adjustment range, tank and flow capacities, and all safety precautions required for operating and maintaining the equipment. Provide and maintain machines, tools, and equipment used in the performance of the work in satisfactory operating condition, or remove them from the work site. Provide mobile and maneuverable application equipment to the extent that straight lines can be followed and normal curves can be made in a true arc. 2.1.2.1 Paint Application Equipment 2.1.2.1.1 Hand-Operated, Push-Type Machines Provide hand-operated push-type applicator machine of a type commonly used for application of water based paint or two-component, chemically curing paint, thermoplastic, or preformed tape, to pavement surfaces for small marking projects, such as legends and cross-walks, parking areas, or surface painted signs. Provide applicator machine equipped with the necessary tanks and spraying nozzles capable of applying paint uniformly at coverage specified. Hand operated spray guns may be used in areas where push-type machines cannot be used. 2.1.2.1.2 Self-Propelled or Mobile-Drawn Spraying Machines Provide self-propelled or mobile-drawn spraying machine with suitable arrangements of atomizing nozzles and controls to obtain the specified results. Provide machine having a speed during application capable of applying the stripe widths indicated at the paint coverage rate specified herein and of even uniform thickness with clear-cut edges. 2.1.2.1.2.1 Road Marking Provide equipment used for marking roads capable of placing the prescribed number of lines at a single pass as solid lines, intermittent lines, or a combination of solid and intermittent lines using a maximum of three different colors of paint as specified. 2.1.2.1.2.2 Hand Application Provide spray guns for hand application of paint in areas where the mobile paint applicator cannot be used. 2.1.2.2 Thermoplastic Application Equipment 2.1.2.2.1 Thermoplastic Material Apply thermoplastic material with equipment that is capable of providing continuous uniformity in the dimensions and reflectorization of the marking. 2.1.2.2.2 Application Equipment a. Provide application equipment capable of continuous mixing and agitation of the material, with conveying parts which prevent accumulation and clogging between the main material reservoir and the SECTION 32 17 23 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% extrusion shoe or spray gun. All parts of the equipment which come into contact with the material must be easily accessible and exposed for cleaning and maintenance. All mixing and conveying parts up to and including the extrusion shoes and spray guns must maintain the material at the required temperature with heat-transfer oil or electrical-element-controlled heat. b. Provide application equipment constructed to ensure continuous uniformity in the dimensions of the stripe. Provide an applicator with a means for cleanly cutting off stripe ends squarely and providing a method of applying "skiplines." Provide equipment capable of applying varying widths of traffic markings. c. Provide mobile and maneuverable application equipment allowing straight lines to be followed and normal curves to be made in a true arc. Provide equipment used for the placement of thermoplastic pavement markings of two general types: mobile applicator and portable applicator. d. Equip the applicator with a pressurized or drop-on type bead dispenser capable of uniformly dispensing reflective glass spheres at controlled rates of flow. The bead dispenser must operate automatically to begin flow prior to the flow of binder to assure that the strip is fully reflectorized. 2.1.2.2.3 Mobile Application Equipment Provide a truck-mounted, self-contained pavement marking machine that is capable of hot applying thermoplastic by either the extrusion or spray method. a. Equip the unit to apply the thermoplastic marking material at temperatures according to the manufacturer's instructions, at widths varying from 3 to 12 inches, with an automatic pressurized or drop-on bead dispensing system, capable of operating continuously, and of installing a minimum of 20,000 lineal feet of longitudinal markings in an 8-hour day. b. Equip the mobile unit with a melting kettle which holds a minimum of 6000 pounds of molten thermoplastic material; capable of heating the thermoplastic composition to temperatures as recommended by the manufacturer. Use a thermostatically controlled heat transfer liquid. Heating of the composition by direct flame is not allowed. Oil and material temperature gauges must be visible at both ends of the kettle. c. Equip mobile units for application of extruded markings with a minimum of two extrusion shoes; located one on each side of the truck, capable of marking simultaneous edge line and centerline stripes; each being a closed, oil-jacketed unit; holding the molten thermoplastic at a temperature as recommended by the manufacturer; and capable of extruding a line of 3 to 8 inches in width; and at a thickness of not less than 0.120 inch nor more than 0.190 inch, of generally uniform cross section. d. Equip mobile units for application of spray markings with a spray gun system capable of marking simultaneous edgeline and centerline stripes. Surround (jacket) the spray system with heating oil to maintain the molten thermoplastic at a temperature of 375 to 425 SECTION 32 17 23 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% degrees F, capable of spraying a stripe of 3 to 12 inches in width, and in thicknesses varying from 0.060 inch to 0.098 inch, of generally uniform cross section. e. Equip the mobile unit with an electronic programmable line pattern control system, capable of applying skip or solid lines in any sequence, through any and all of the extrusion shoes, or the spray guns, and in programmable cycle lengths. In addition, equip the mobile unit with an automatic counting mechanism capable of recording the number of lineal feet of thermoplastic markings applied to the pavement surface with an accuracy of 0.5 percent. 2.1.2.2.4 Portable Application Equipment Provide portable hand-operated equipment, specifically designed for placing special markings such as crosswalks, stop bars, legends, arrows, and short lengths of lane, edge and centerlines; and capable of applying thermoplastic pavement markings by the extrusion method. Equip the portable applicator with all the necessary components, including a materials storage reservoir, bead dispenser, extrusion shoe, and heating accessories, capable of holding the molten thermoplastic at the temperature recommended by the manufacturer, and of extruding a line of 3 to 12 inches in width, and in thickness of not less than 0.120 inch nor more than 0.190 inch and of generally uniform cross section. 2.2 MATERIALS Use reflectorized thermoplastic for roads. Use paint for no parking striped areas. The maximum allowable VOC content of pavement markings is 150 grams per liter. Color of markings are indicated on the drawings and must conform to ASTM D6628 for roads and parking areas and FED-STD-595 for airfields. Provide materials conforming to the requirements specified herein. 2.2.1 Waterborne Paint FS TT-P-1952, Type I or II III. 2.2.2 Solventborne Paint AASHTO M 248. 2.2.3 Methacrylate Paint Formulate methacrylate paint to meet the requirements of FAA AC 150/5370-10, Item P-620.2, Methacrylate. 2.2.4 Epoxy Paint 2.2.4.1 Formulation Epoxy pavement marking material will be a two component, 100 percent solids, material formulated to provide simple volumetric mixing ratio of two volumes of component A and one volume of component B unless otherwise recommended by the manufacturer. 2.2.4.2 Composition The component A of both white and yellow must be within the following SECTION 32 17 23 Page 8 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% limits: TABLE I White Yellow Pigments Minimum 18 percent by weight Titanium Dioxide (ASTM D476, Type II) 21-27 percent by weight Epoxy Resin 75-82 percent 73-79 percent The epoxy resign must be free of lead, cadmium, mercury, hexavalent chromium and other toxic heavy metals as defined by the Environmental Protection Agency. Submit a manufacturer's certification of compliance with this requirement. 2.2.4.3 Epoxide Value Determine epoxide epoxy number of the epoxy resin in accordance with ASTM D1652 for white and yellow component A on pigment free basis. The epoxide number must be within plus or minus 50 of the published manufacturer's standard. 2.2.4.4 Total Amine Value Determine the amine number on the curing agent (component B) in accordance with ASTM D2074. The amine number must be within plus or minus 50 of the published manufacturer's standard. 2.2.4.5 Toxicity Upon heating to application temperature, the material must not produce fumes which are toxic or injurious to persons or property. 2.2.4.6 Daylight Directional Reflectance Directional reflectance of white and yellow paint (without glass beads) in accordance with ASTM E1347: White 84 percent Yellow 55 percent. 2.2.4.7 Laboratory Drying Time The epoxy pavement marking material must have a maximum no-pick-up time of 30 minutes when tested in accordance with ASTM D711. 2.2.4.8 Curing The epoxy material must be capable of fully curing under a constant surface temperature of 45 Degrees F or above. 2.2.4.9 Adhesion to Concrete The catalyzed epoxy pavement marking material must have a high degree of adhesion to the specified concrete surface (100 percent concrete failure) when tested according to ASTM D7234. The concrete substrate must have a minimum compressive strength of 4,000 psi. Condition prepared specimens at a temperature of 75 plus or minus 2 Degrees F for a minimum of 24 hours SECTION 32 17 23 Page 9 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% and a maximum of 72 hours prior to performance of the test. 2.2.4.10 Hardness Epoxy pavement marking materials must have a Shore D Hardness between 75 and 100 when tested in accordance with ASTM D2240. Cure the samples at 75 plus or minus 2 Degrees F for a minimum of 72 hours and a maximum of 96 hours prior to performing the tests. 2.2.4.11 Abrasion Resistance The wear index for a catalyzed sample must not exceed 82 when tested in accordance with ASTM D4060 using a 1000 gram load, CS-17 wheels and a test duration of 1000 cycles. Run the test on cured samples of material which have been applied at a film thickness of 15 plus or minus 0.5 mils to code S-16 stainless steel plates. Cure the samples at 75 plus or minus 2 Degrees F for a minimum of 48 hours prior to performing the tests. 2.2.4.12 Tensile Strength Epoxy pavement marking materials must have a tensile strength of at least 6,000 psi when tested in accordance with ASTM D638. Cast the Type IV specimens in a suitable mold and pull at the rate of 1/4 inch per minute using a suitable dynamic testing machine. Cure the samples at 75 plus or minus 2 Degrees F for a minimum of 12 hours and a maximum of 48 hours prior to performing the tests. 2.2.4.13 Compressive Strength Catalyzed epoxy pavement marking materials must have a compressive strength of at least 12,000 psi when tested in accordance with ASTM D695. Condition the cast sample at 75 plus or minus 2 Degrees F for a minimum of 12 hours and a maximum of 48 hours prior to performing the tests. The rate of compression of these samples must not exceed 1/4 inch per minute. 2.2.5 Thermoplastic Compound 2.2.5.1 Composition Requirements Thermoplastic compound must conform to AASHTO M 249. Formulate the binder component as an alkyd resin. 2.2.5.2 Primer a. Asphalt concrete primer: Provide thermosetting adhesive primer with a solids content of pigment reinforced synthetic rubber and synthetic plastic resin dissolved or dispersed in a volatile organic solvent for asphaltic concrete pavements. The solids content must not be less than 10 percent by weight at 70 degrees F and 60 percent relative humidity. A wet film thickness of 0.005 inch, plus or minus 0.001 inch, must dry to a tack-free condition in less than 5 minutes. b. Portland cement concrete primer: Provide an epoxy resin primer for portland cement concrete pavements, of the type recommended by the manufacturer of the thermoplastic composition. 2.2.6 High Build Acrylic Coating (HBAC) Formulate High Build Acrylic Coating (HBAC) to meet the requirements of SECTION 32 17 23 Page 10 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Table II. TABLE II - REQUIREMENTS FOR HIGH BUILD ACRYLIC COATINGS (HBAC) TEST MINIMUM REQUIREMENT (AND MAXIMUM WHERE INDICATED) Resin System (ASTM D2621)Waterborne 100 percent Acrylic Percent Volume Solids (ASTM D2697)58 percent Volatile Organic Compound, max. (ASTM D3960 ) 1.25 lbs/gal White (FED-STD-595)37925 Yellow (FED-STD-595)33538 Shore D Hardness (ASTM D2240)45 1/8 inch Mandrel Bend at 5 mils Dry Film Thickness (DFT, one-week cure ( ASTM D522/D522M, Method B) No visual defects at bend (Conditions at ASTM D3924) Adhesion to Concrete and Asphaltic Pavements (ASTM D4541) 140 psi or 100 percent cohesive failure in pavement Accelerated Weathering, Yellow, 2500 Hours UV Exposure (ASTM G154: see note 1) Max. color loss to 33655 (FED-STD-595) Water Absorption at 168 Hours Immersion Tap Water (ASTM D471) 9.0 percent max. weight increase (conditions at ASTM D3924) Application at 65 mils Wet,One Coat, One-week Cure, (see note 2) No visual cracking or curling (conditions at ASTM D3924) No Pick-Up at 25 mils (ASTM D711)Wet 10 minutes max. Lead (ASTM D3335)0.06 percent max. Cadmium (ASTM D3335)0.06 percent max. Chromium (ASTM D3718)0.00 percent SECTION 32 17 23 Page 11 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% TABLE II - REQUIREMENTS FOR HIGH BUILD ACRYLIC COATINGS (HBAC) TEST MINIMUM REQUIREMENT (AND MAXIMUM WHERE INDICATED) Notes: (1) Properly mix and apply yellow paint at 10 mils plus or minus 2 mils DFT over a suitably sized, clean aluminum substrate (ASTM D823), and cure for a minimum of 48 hours: four individual yellow samples shall be prepared. Expose three samples to continuous Ultraviolet (UV) light for 2500 hours, without cycles condensation, in accordance to ASTM G154: UVA-340 lamps shall be used in the testing apparatus. Following exposure, compare the three exposed samples to the "one" non-exposed sample using FED-STD-595 colors 33538 and 33655 as visual references: evaluate exposed samples for degree of visual color loss. Yellow paint shall receive a passing rating if each exposed sample appears equivalent to the non-exposed sample, and in addition, displays color loss no greater than FED-STD-595 color 33655. (2) Using double-stick, foam mounting tape (or equal) with a nominal thickness of 65 mils, apply a rectangular mold with inner dimensions of 3 in by 10 in to a clean aluminum sample approximately sized at 6 in by 12 in by 1/8 in. Do not remove the tape's plastic backing. Mix and apply excess paint into mold. Remove excess paint, by squeegee or other appropriate draw down technique, to a uniform thickness equal to the tape's height. Paint application and draw down shall be performed within a period of no more than 60 seconds. Approximately one to two minutes following the draw down, remove tape from sample and allow coating to cure for a minimum period of one week ASTM D3924. Using a micrometer or other appropriate device, measure cured coating thickness (less sample thickness) to confirm resulting coating application was at or above 38 mils DFT. Inspect coating for visual signs of cracking and curling. Following a one week cure, coating shall receive a passing rating if applied greater than 38 mils DFT and visually free of both cracking and curling. PART 3 EXECUTION 3.1 EXAMINATION 3.1.1 Testing for Moisture Test the pavement surface for moisture before beginning pavement marking after each period of rainfall, fog, high humidity, or cleaning, or when the ambient temperature has fallen below the dew point. Do not commence marking until the pavement is sufficiently dry and the pavement condition has been approved by the Contracting Officer or authorized representative. Employ the "plastic wrap method" to test the pavement for moisture as follows: Cover the pavement with a 12 inch by 12 inch section of clear plastic wrap and seal the edges with tape. After 15 minutes, examine the SECTION 32 17 23 Page 12 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% plastic wrap for any visible moisture accumulation inside the plastic. Do not begin marking operations until the test can be performed with no visible moisture accumulation inside the plastic wrap. Re-test surfaces when work has been stopped due to rain. 3.1.2 Surface Preparation Demonstration Prior to surface preparation, demonstrate the proposed procedures and equipment. Prepare areas large enough to determine cleanliness, adhesion of remaining coating and rate of cleaning. 3.1.3 Test Stripe Demonstration Prior to paint application, demonstrate test stripe application within the work area using the proposed materials and equipment. Apply separate test stripes in each of the line widths and configurations required herein using the proposed equipment. Make the test stripes long enough to determine the proper speed and operating pressures for the vehicle(s) and machinery, but not less than 50 feet long. 3.1.4 Application Rate Demonstration During the Test Stripe Demonstration, demonstrate compliance with the application rates specified herein. Document the equipment speed and operating pressures required to meet the specified rates in each configuration of the equipment and provide a copy of the documentation to the Contracting Officer prior to proceeding with the work. 3.1.5 Level of Performance Demonstration The Contracting Officer will be present at the application demonstrations to observe the results obtained and to validate the operating parameters of the vehicle(s) and equipment. If accepted by the Contracting Officer, the test stripe is the measure of performance required for this project. Do not proceed with the work until the demonstration results are satisfactory to the Contracting Officer. 3.2 EXTERIOR SURFACE PREPARATION Allow new pavement surfaces to cure for a period of not less than 30 days before application of marking materials. Thoroughly clean surfaces to be marked before application of the paint. Remove dust, dirt, and other granular surface deposits by sweeping, blowing with compressed air, rinsing with water, or a combination of these methods as required. Remove residual curing compounds, and other coatings adhering to the pavement. a. For Portland Cement Concrete pavement, grinding, light shot blasting, or light scarification, to a resulting profile equal to ICRI 03732 CSP 2, CSP 3, and CSP 4, respectively, can be used in addition to water blasting on most pavements, to either remove existing coatings, or for surface preparation. b. Do not use shot blasting on airfield pavements due to the potential of Foreign Object Damage (FOD) to aircraft. Scrub affected areas, where oil or grease is present on old pavements to be marked, with several applications of trisodium phosphate solution or other approved detergent or degreaser and rinse thoroughly after each application. After cleaning oil-soaked areas, seal with shellac or primer recommended by the manufacturer to prevent bleeding through the new SECTION 32 17 23 Page 13 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% paint. Do not commence painting in any area until pavement surfaces are dry and clean. 3.2.1 Early Painting of Rigid Pavements Pretreat rigid pavements that require early painting with an aqueous solution containing 3 percent phosphoric acid and 2 percent zinc chloride. Apply the solution to the areas to be marked. 3.2.2 Early Painting of Asphalt Pavements For asphalt pavement systems requiring painting application at less than 30 days, apply the paint and beads at half the normal application rate, followed by a second application at the normal rate after 30 days. 3.3 APPLICATION Apply pavement markings to dry pavements only. 3.3.1 Paint Apply paint pneumatically with approved equipment at rate of coverage specified herein. Provide guidelines and templates as necessary to control paint application. Take special precautions in marking numbers, letters, and symbols. Manually paint numbers, letters, and symbols. Sharply outline all edges of markings. The maximum drying time requirements of the paint specifications will be strictly enforced, to prevent undue softening of bitumen, and pickup, displacement, or discoloration by tires of traffic. If there is a deficiency in drying of the markings, painting operations must cease until the cause of the slow drying is determined and corrected. 3.3.1.1 Waterborne Paint 3.3.1.2 Solventborne Paint Apply paint at a minimum wet film thickness of 15 mils. Apply FS TT-B-1325 Type I (Gradation A) or AASHTO M 247 Type 1 beads at a minimum rate of 6 pounds of glass spheres per gallon. 3.3.1.3 Epoxy Paint Apply paint evenly to the pavement surface at a wet film thickness of 20 mils plus or minus 1 mil to cover 80 plus or minus 4 square feet per gallon. Apply glass spheres uniformly to the wet paint on road and street pavement at a rate of 7 plus or minus 0.5 pounds of glass spheres per gallon. 3.3.1.4 High Build Acrylic Coating Apply High Build Acrylic Coating (HBAC) at a rate of 50 square feet per gallon. Apply Type IV (Gradation A) beads at a minimum rate of 16 pounds of glass spheres per gallon. 3.3.2 Thermoplastic Compound Place thermoplastic pavement markings, free from dirt or tint, upon dry pavement. The temperature must be a minimum of 40 degrees F and rising at the time of installation. Apply all centerline, skipline, edgeline, and other longitudinal type markings with a mobile applicator. Place all SECTION 32 17 23 Page 14 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% special markings, crosswalks, stop bars, legends, arrows, and similar patterns with a portable applicator, using the extrusion method. 3.3.3 Cleanup and Waste Disposal Keep the worksite clean and free of debris and waste from the removal and application operations. Dispose of debris at approved sites. 3.4 FIELD QUALITY CONTROL 3.4.1 Sampling and Testing As soon as the paint and thermoplastic materials are available for sampling, obtain by random selection from the sealed containers, two quart samples of each batch in the presence of the Contracting Officer. Accomplish adequate mixing prior to sampling to ensure a uniform, representative sample. A batch is defined as that quantity of material processed by the manufacturer at one time and identified by number on the label. Clearly identify samples by designated name, specification number, batch number, project contract number, intended use, and quantity involved. At the discretion of the Contracting Officer, samples provided may be tested by the Government for verification. 3.4.2 Material Inspection Examine material at the job site to determine that it is the material referenced in the report of test results or certificate of compliance. 3.4.3 Dimensional Tolerances Apply all markings in the standard dimensions provide in the drawings. New markings may deviate a maximum of 10 percent larger than the standard dimension. The maximum deviation allowed when painting over an old marking is up to 20 percent larger than the standard dimensions. 3.4.4 Bond Failure Verification Inspect newly applied markings for signs of bond failure based on visual inspection and comparison to results from Test Stripe Demonstration paragraph. -- End of Section -- SECTION 32 17 23 Page 15 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 32 31 13 CHAIN LINK FENCES AND GATES 11/16 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. ASTM INTERNATIONAL (ASTM) ASTM A116 (2011) Standard Specification for Metallic-Coated, Steel Woven Wire Fence Fabric ASTM A153/A153M (2016) Standard Specification for Zinc Coating (Hot-Dip) on Iron and Steel Hardware ASTM A702 (2013) Standard Specification for Steel Fence Posts and Assemblies, Hot Wrought ASTM A780/A780M (2009; R 2015) Standard Practice for Repair of Damaged and Uncoated Areas of Hot-Dip Galvanized Coatings ASTM A90/A90M (2013; R 2018) Standard Test Method for Weight Mass of Coating on Iron and Steel Articles with Zinc or Zinc-Alloy Coatings ASTM C94/C94M (2018) Standard Specification for Ready-Mixed Concrete ASTM F1043 (2018) Standard Specification for Strength and Protective Coatings on Steel Industrial Fence Framework ASTM F1083 (2018) Standard Specification for Pipe, Steel, Hot-Dipped Zinc Coated (Galvanized) Welded, for Fence Structures ASTM F567 (2014a) Standard Practice for Installation of Chain Link Fence ASTM F626 (2014) Standard Specification for Fence Fittings ASTM F883 (2013) Padlocks U.S. GENERAL SERVICES ADMINISTRATION (GSA) FS RR-F-191 (Rev K) Fencing, Wire and Post Metal (and Gates, Chain-Link Fence Fabric, and Accessories) SECTION 32 31 13 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% FS RR-F-191/1 (Rev F) Fencing, Wire and Post, Metal (Chain-Link Fence Fabric) FS RR-F-191/2 (Rev E) Fencing, Wire and Post, Metal (Chain-Link Fence Gates) FS RR-F-191/3 (Rev E; Am 1) Fencing, Wire and Post, Metal (Chain-Link Fence Posts, Top Rails and Braces) FS RR-F-191/4 (Rev F) Fencing, Wire and Post, Metal (Chain-Link Fence Accessories) 1.2 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-02 Shop Drawings Fence Assembly Location of Gate, Corner, End, and Pull Posts Gate Assembly Gate Hardware and Accessories Erection/Installation Drawings SD-03 Product Data Fence Assembly Gate Assembly Gate Hardware and Accessories Zinc Coating Fabric Stretcher Bars Concrete SD-04 Samples Fabric Posts SD-07 Certificates SECTION 32 31 13 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Certificates of Compliance SD-08 Manufacturer's Instructions Fence Assembly Gate Assembly Hardware Assembly Accessories SD-11 Closeout Submittals Recycled Material Content 1.3 QUALITY CONTROL 1.3.1 Certificates of Compliance Submit certificates of compliance in accordance with the applicable reference standards and descriptions of this section for the following: a. Zinc coating b. Fabric c. Stretcher bars d. Gate hardware and accessories e. Concrete 1.4 DELIVERY, STORAGE, AND HANDLING Deliver materials to site in an undamaged condition. Store materials off the ground to provide protection against oxidation caused by ground contact. PART 2 PRODUCTS 2.1 SYSTEM DESCRIPTION Provide fencing materials conforming to the requirements of ASTM A116, ASTM A702, ASTM F626. Submit reports of listing chain-link fencing and accessories regarding weight in ounces for zinc coating. Submit manufacturer's catalog data for complete fence assembly, gate assembly, hardware assembly and accessories. 2.2 COMPONENTS 2.2.1 Fabric FS RR-F-191 and detailed specifications as referenced and other requirements as specified. SECTION 32 31 13 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% FS RR-F-191/1; Type I, zinc-coated steel. Mesh size, 2 inches. Provide selvage knuckled at both selvages. Height of fabric, as indicated. Provide fabric consisting of No. 9-gage wires woven into a 2 inch diamond mesh, with dimensions of fabric and wire conforming to ASTM A116, with 1.20 ounces per square foot zinc galvanizing. 2.2.1.1 Top and Bottom Selvages Provide knuckled selvages at top and bottom for fabric with 2 inch mesh and up to 60 inches high, and if over 60 inches high, provide twisted and barbed top selvage and knuckled bottom selvage. Knuckle top and bottom selvages for 1-3/4 inch and 1 inch mesh fabric. 2.2.2 Posts, Rails and Braces FS RR-F-191/3 line posts; Class 1, steel pipe, Grade A. End, corner, and pull posts; Class 1, steel pipe, Grade A. Braces and rails; Class 1, steel pipe, Grade A in minimum sizes listed in FS RR-F-191/3 for each class and grade. 2.2.3 Line Posts Minimum acceptable line posts are as follows: Up to 6 feet high: Grade A: 1.900 inch O.D. pipe weighing 2.72 pounds per linear foot. Grade B: 2.375 inch O.D. pipe weighing 3.12 pounds per linear foot. Over 6 feet high: 2.0 inch O.D. pipe weighing 3.65 pounds per linear foot. 2.2.4 End, Corner, and Pull Posts Provide minimally acceptable end, corner, and pull posts as follows: Up to 6 feet high: Grade A: 2.375 inch O.D. pipe weighing 3.65 pounds per linear foot. Grade B: 2.375 inch O.D. pipe weighing 3.12 pounds per linear foot. Over 6 feet high: Grade A: 2.875 inch O.D. pipe weighing 5.79 pounds per linear foot. Grade B: 2.875 inch O.D. pipe weighing 4.64 pounds per linear foot. 2.2.5 Sleeves Provide sleeves for setting into concrete construction of the same material as post sections, sized 1 inch greater than the diameter or dimension of the post. Weld flat plates to each sleeve base to provide anchorage and prevent intrusion of concrete. SECTION 32 31 13 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.2.6 Top Rail Provide top rails with a minimum of 1.660 inches O.D. pipe rails. Provide expansion couplings 6 inches long at each joint in top rails. 2.2.7 Bottom Rail Provide bottom rail conforming to minimum sizes specified in FS RR-F-191/3 for each class and grade unless members are to be oversized. 2.2.8 Post-Brace Assembly Provide bracing consisting of 1.660 inches O.D. pipe Grade A weighing 2.27 pounds per linear foot and 3/8 inch adjustable truss rods and turnbuckles. 2.2.9 Stretcher Bars Provide bars that have one-piece lengths equal to the full height of the fabric with a minimum cross section of 3/16 by 3/4 inch, in accordance with ASTM F626. 2.2.10 Stretcher Bar Bands Provide bar bands for securing stretcher bars to posts that are steel, wrought iron, or malleable iron spaced not over 15 inches on center. Bands may also be used in conjunction with special fittings for securing rails to posts. Provide bands with projecting edges chamfered or eased. 2.2.11 Post Tops Provide tops that are steel, wrought iron, or malleable iron designed as a weathertight closure cap. Provide one cap for each post, unless equal protection is provided by a combination post-cap and wire supporting arm. Provide caps with an opening to permit through passage of the top rail. 2.2.12 Gate Posts Provide a gate post for supporting each gate leaf as follows: Up to 6-feet wide: 2.875 inch O.D. pipe Grade A weighing 5.79 pounds per linear foot. Over 6 feet wide and up to 13 feet wide: 2.875 inch O.D. pipe Grade A weighing 5.79 pounds per linear foot. Over 13-feet and up to 18-feet wide: Provide 6.625 inch O.D. pipe weighing 18.97 pounds per linear foot. Over 18-feet wide: Provide 8.625 inch O.D. pipe weighing 24.70 pounds per linear foot. SECTION 32 31 13 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.2.13 Gates FS RR-F-191/2; Type I, single swing II, double swing III, single cantilever sliding, wheel sliding gate IV, double cantilever sliding. Shape and size of gate frame, as indicated. Framing and bracing members, round of steel alloy. Steel member finish, zinc-coated. Provide gate frames and braces of minimum sizes listed in FS RR-F-191/3 for each Class and Grade, except that steel pipe frames are a minimum of 1.90 inches o.d., 0.120 inches minimum wall thickness and aluminum pipe frames and intermediate braces are 1.869 inches o.d. minimum, 0.940 lb/ft of length. Gate fabric, is as specified for fencing fabric. Coating for steel latches, stops, hinges, keepers, and accessories, is galvanized Provide fork type gate latches. Provide intermediate members as necessary for gate leaves more than 8 feet wide, to provide rigid construction, free from sag or twist. Provide truss rods or intermediate braces for gate leaves less than 8 feet wide. Attach gate fabric to gate frame in accordance with manufacturer's standards, except that welding is not permitted. Arrange padlocking latches to be accessible from both sides of gate, regardless of latching arrangement. For gate leaves up to 6 feet high or 6 feet wide, provide perimeter gate frames of 1.66 inch O.D. pipe Grade A weighing 2.27 pounds per linear foot. For gate leaves over 6 feet high or 6 feet wide, provide perimeter gate frames of 1.90 inch O.D. pipe Grade A weighing 2.72 pounds per linear foot. Provide gate frame assembly that is welded or assembled with special malleable or pressed-steel fittings and rivets to provide rigid connections. Install fabric with stretcher bars at vertical edges; stretcher bars may also be used at top and bottom edges. Attach stretcher bars and fabric to gate frames on all sides at intervals not exceeding 15 inches. Attach hardware with rivets or by other means which provides equal security against breakage or removal. Provide diagonal cross-bracing, consisting of 3/8 inch diameter adjustable-length truss rods on welded gate frames, where necessary to obtain frame rigidity without sag or twist. Provide nonwelded gate frames with diagonal bracing. 2.2.14 Gate Hardware and Accessories Provide gate hardware and accessories that conforms to ASTM A116 and ASTM F626, and be as specified: Provide hinges to suit gate size, non-lift-off type, offset to permit 180-degree opening. Provide latch that permits operation from either side of the gate, with a padlock eye provided as an integral part of the latch. Provide stops and holders of malleable iron for vehicular gates. Provide stops that automatically engage the gate and hold it in the open position until manually released. Provide double gates with a cane bolt and ground-set keeper, with latch or locking device and padlock eye designed as an integral part. SECTION 32 31 13 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Provide manufacturer's standard heavy-duty track ball bearing hanger sheaves, overhead framing and supports, guides, stays, bracing, and accessories as required for easy operation of manual sliding gates. 2.2.15 Miscellaneous Hardware Provide miscellaneous hot-dip galvanized hardware as required. 2.2.16 Wire Ties Provide 16-gage galvanized steel wire for tying fabric to line posts,spaced 12 inches on center. For tying fabric to rails and braces, space wire ties 24 inches on center. For tying fabric to tension wire, space 0.105-inch hog rings 24 inches on center. Manufacturer's standard procedure will be accepted if of equal strength and durability. FS RR-F-191/4. Provide wire ties constructed of the same material as the fencing fabric. 2.2.17 Padlocks Provide padlocks conforming to ASTM F883, with chain. 2.3 MATERIALS 2.3.1 Zinc Coating Provide hot-dip galvanized (after fabrication) ferrous-metal components and accessories, except as otherwise specified. Provide zinc coating of weight not less than 1.94 ounces per square foot, as determined from the average result of two specimens, when tested in accordance with ASTM A90/A90M. Provide zinc coating conforming to the requirements of the following: a. Pipe: FS RR-F-191/3 Class 1 Grade A in accordance with ASTM F1083. b. Hardware and accessories: ASTM A153/A153M, Table 1 c. Surface: ASTM F1043 d. External: Type B-B surface zinc with organic coating, 0.97 ounce per square foot minimum thickness of acrylated polymer. e. Internal: Surface zinc coating of 0.97 ounce per square foot minimum. Provide galvanizing repair material that is cold-applied zinc-rich coating conforming to ASTM A780/A780M. 2.3.2 Tension Wire Provide galvanized, coiled spring wire, No. 7-gage. Provide zinc coating that weighs not less than 1.2 ounces per square foot. SECTION 32 31 13 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.3.3 Concrete Provide concrete conforming to ASTM C94/C94M, and obtaining a minimum 28-day compressive strength of 3,000 psi. 2.3.4 Grout Provide grout of proportions one part portland cement to three parts clean, well-graded sand and a minimum amount of water to produce a workable mix. PART 3 EXECUTION Submit manufacturer's erection/installation drawings and instructions that detail proper assembly and materials in the design for fence, gate, hardware and accessories. Provide complete installation conforming to ASTM F567. 3.1 PREPARATION Ensure final grading and established elevations are complete prior to commencing fence installation. 3.1.1 Clearing and Grading Clear fence line of trees, brush, and other obstacles to install fencing for a distance of 20 feet inside; and 10 feet outside the fence. Establish a graded, compacted fence line prior to fencing installation. 3.2 INSTALLATION 3.2.1 Fence Installation Install fence on prepared surfaces to line and grade indicated. Install fence in accordance with fence manufacturer's written installation instructions except as modified herein. 3.2.1.1 Post Spacing Provide line posts spaced equidistantly apart, not exceeding 10 feet on center. Provide gate posts spaced as necessary for size of gate openings. Do not exceed 500 feet on straight runs between braced posts. Provide corner or pull posts, with bracing in both directions, for changes in direction of 15 degrees or more, or for abrupt changes in grade. Submit drawings showing location of gate, corner, end, and pull posts. 3.2.1.2 Top and Bottom Tension Wire Install top and bottom tension wires before installing chain-link fabric, and pull wires taut. Place top and bottom tension wires within 8 inches of respective fabric line. 3.2.2 Excavation Provide excavations for post footings which are drilled holes in virgin or compacted soil, of minimum sizes as indicated. Space footings for line posts 10 feet on center maximum and at closer SECTION 32 31 13 Page 8 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% intervals when indicated, with bottoms of the holes approximately 3 inches below the bottoms of the posts. Set bottom of each post not less than 36 inches below finished grade when in firm, undisturbed soil. Set posts deeper, as required, in soft and problem soils and for heavy, lateral loads. Uniformly spread soil from excavations adjacent to the fence line or on areas of Government property, as directed. When solid rock is encountered near the surface, drill into the rock at least 12 inches for line posts and at least 18 inches for end, pull, corner, and gate posts. Drill holes at least 1 inch greater in diameter than the largest dimension of the placed post. If solid rock is below the soil overburden, drill to the full depth required except that penetration into rock need not exceed the minimum depths specified above. 3.2.3 Setting Posts Remove loose and foreign materials from holes and moisten the soil prior to placing concrete. Provide tops of footings that are trowel finished and sloped or domed to shed water away from posts. Set hold-open devices, sleeves, and other accessories in concrete. Keep exposed concrete moist for at least 7 calendar days after placement or cured with a membrane curing material, as approved. Grout all posts set into sleeved holes in concrete with an approved grouting material. Maintain vertical alignment of posts in concrete construction until concrete has set. 3.2.3.1 Earth and Bedrock Provide concrete bases of dimensions indicated on the manufactures installation drawings, except in bedrock. Compact concrete to eliminate voids, and finish to a dome shape. In bedrock, set posts with a minimum of 1 inch of grout around each post. Work grout into hole to eliminate voids, and finish to a dome shape. 3.2.3.2 Bracing Brace gate, corner, end, and pull posts to nearest post with a horizontal brace used as a compression member, placed at least 12 inches below top of fence, and a diagonal tension rod. a. Tolerances Provide posts that are straight and plumb within a vertical tolerance of 1/4 inch after the fabric has been stretched. Provide fencing and gates that are true to line with no more than 1/2 inch deviation from the established centerline between line posts. Repair defects as directed. 3.2.4 Concrete Strength Provide concrete that has attained at least 75 percent of its minimum SECTION 32 31 13 Page 9 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 28-day compressive strength, but in no case sooner than 7 calendar days after placement, before rails, tension wire, or fabric are installed. Do not stretch fabric and wires or hang gates until the concrete has attained its full design strength. Take samples and test concrete to determine strength as specified. 3.2.5 Top Rails Provide top rails that run continuously through post caps or extension arms, bending to radius for curved runs. Provide expansion couplings as recommended by the fencing manufacturer. 3.2.6 Brace Assembly Provide bracing assemblies at end and gate posts and at both sides of corner and pull posts, with the horizontal brace located at midheight of the fabric. Install brace assemblies so posts are plumb when the diagonal rod is under proper tension. Provide two complete brace assemblies at corner and pull posts where required for stiffness and as indicated. 3.2.7 Tension Wire Installation Install tension wire by weaving them through the fabric and tying them to each post with not less than 7-gage galvanized wire or by securing the wire to the fabric with 10-gage ties or clips spaced 24 inches on center. 3.2.8 Fabric Installation Provide fabric in single lengths between stretch bars with bottom barbs placed approximately 1-1/2 inches above the ground line. Pull fabric taut and tied to posts, rails, and tension wire with wire ties and bands. Install fabric on the security side of fence, unless otherwise directed. Ensure fabric remains under tension after the pulling force is released. 3.2.9 Stretcher Bar Installation Thread stretcher bars through or clamped to fabric 4 inches on center and secured to posts with metal bands spaced 15 inches on center. 3.2.10 Gate Installation Install gates plumb, level, and secure, with full opening without interference. Install ground set items in concrete for anchorage as recommended by the fence manufacturer. Adjust hardware for smooth operation and lubricated where necessary. 3.2.11 Tie Wires Provide tie wires that are U-shaped to the pipe diameters to which attached. Twist ends of tie wires not less than two full turns and bent so as not to present a hazard. SECTION 32 31 13 Page 10 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.2.12 Fasteners Install nuts for tension bands and hardware on the side of the fence opposite the fabric side. Peen ends of bolts to prevent removal of nuts. 3.2.13 Zinc-Coating Repair Clean and repair galvanized surfaces damaged by welding or abrasion, and cut ends of fabric, or other cut sections with specified galvanizing repair material applied in strict conformance with the manufacturer's printed instructions. 3.2.14 Accessories Installation 3.2.14.1 Post Caps Design post caps to accommodate top rail. Install post caps as recommended by the manufacturer. 3.2.14.2 Padlocks Provide padlocks for gate openings and provide chains that are securely attached to gate or gate posts. Provide padlocks keyed alike, and provide two keys for each padlock. 3.3 CLOSEOUT ACTIVITIES Remove waste fencing materials and other debris from the work site. Submit manufacturer's data indicating percentage of recycled material content in protective fence materials, including chain link fence, fabric, and gates to verify affirmative procurement compliance. -- End of Section -- SECTION 32 31 13 Page 11 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 32 92 19 SEEDING 08/17 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. ASTM INTERNATIONAL (ASTM) ASTM C602 (2013a) Agricultural Liming Materials ASTM D4427 (2018) Standard Classification of Peat Samples by Laboratory Testing ASTM D4972 (2013) pH of Soils U.S. DEPARTMENT OF AGRICULTURE (USDA) AMS Seed Act (1940; R 1988; R 1998) Federal Seed Act DOA SSIR 42 (1996) Soil Survey Investigation Report No. 42, Soil Survey Laboratory Methods Manual, Version 3.0 1.2 DEFINITIONS 1.2.1 Stand of Turf 95 percent ground cover of the established species. 1.3 RELATED REQUIREMENTS Section 31 00 00 EARTHWORK, and Section 32 05 33 LANDSCAPE ESTABLISHMENT applies to this section for pesticide use and plant establishment requirements, with additions and modifications herein. 1.4 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance with Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SECTION 32 92 19 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.5 DELIVERY, STORAGE, AND HANDLING 1.5.1 Delivery 1.5.1.1 Seed Protection Protect from drying out and from contamination during delivery, on-site storage, and handling. 1.5.1.2 Fertilizer, Gypsum, Sulfur, Iron, and Lime Delivery Deliver to the site in original, unopened containers bearing manufacturer's chemical analysis, name, trade name, trademark, and indication of conformance to state and federal laws. Instead of containers, fertilizer, gypsum, sulphur, iron, and lime may be furnished in bulk with certificate indicating the above information. 1.5.2 Storage 1.5.2.1 Seed, Fertilizer, Gypsum, Sulfur, Iron, and Lime Storage Store in cool, dry locations away from contaminants. 1.5.2.2 Topsoil Prior to stockpiling topsoil, treat growing vegetation with application of appropriate specified non-selective herbicide. Clear and grub existing vegetation three to four weeks prior to stockpiling topsoil. 1.5.2.3 Handling Do not drop or dump materials from vehicles. 1.6 TIME RESTRICTIONS AND PLANTING CONDITIONS 1.6.1 Restrictions Do not plant when the ground is frozen, muddy, or when air temperature exceeds 90 degrees Fahrenheit. 1.7 TIME LIMITATIONS 1.7.1 Seed Apply seed within twenty four hours after seed bed preparation. PART 2 PRODUCTS 2.1 SEED 2.1.1 Classification Provide State-certified State-approved Endophyte-enhanced seed of the latest season's crop delivered in original sealed packages, bearing producer's guaranteed analysis for percentages of mixtures, purity, germination, weedseed content, and inert material. Label in conformance with AMS Seed Act and applicable state seed laws. Wet, moldy, or otherwise damaged seed will be rejected. Field mixes will be acceptable when field mix is performed on site in the presence of the Contracting SECTION 32 92 19 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Officer. 2.1.2 Planting Dates 2.1.2.1 Permanent Seeding "Cool Season": planted between 1 September and 28 February 50 pounds per acre Winter Wheat (Triticum spelta). NO RYE GRASS. 25 pounds per acre common Bermuda (Cynodon dactylon), hulled 25 pounds per acre common Bermuda (Cynodon dactylon), unhulled "Warm Season": planted between 1 March and 31 August 50 pounds per acre German (Setaria italica), Brown Top (Setaria italica), or Fox Tail Millet (Brachiaria ramosum) 50 pounds per acre common Bermuda (Cynodon dactylon), hulled 2.1.2.2 Temporary Seeding "Cool Season": planted between 1 September and 28 February 120 pounds per acre Winter Wheat (Triticum spelta) "Warm Season": planted between 1 March and 31 August 65 pounds per acre German (Setaria italica), Brown Top (Setaria italica), or Fox Tail Millet (Brachiaria ramosum) 2.1.2.3 Hydroseeding Hydroseeding shall only be allowable on slopes steeper than 1 horizontal to 1 vertical. Steps 1 through 4 must be completed prior to hydroseeding. Hydroseeding should be applied in two applications. The first application will consist of 1/3 of the mulch and 2/3 of the seed and the second application will consist of 2/3 of the mulch and 1/3 of the seed. The mulch will include a tackifier and will be applied at a rate of 2,000 pounds per acre or the manufacturer's recommendation, whichever is higher. Proportion seed mixtures by weight. Temporary seeding must later be replaced by permanent seeding plantings for a permanent stand of grass. The same requirements of turf establishment for permanent seeding apply for temporary seeding. 2.2 TOPSOIL 2.2.1 On-Site Topsoil Surface soil stripped and stockpiled on site and modified as necessary to meet the requirements specified for topsoil in paragraph COMPOSITION. When available topsoil must be existing surface soil stripped and stockpiled on-site in accordance with Section 31 00 00 EARTHWORK. 2.2.2 Off-Site Topsoil Conform to requirements specified in paragraph COMPOSITION. Additional topsoil must be furnished by the Contractor. 2.2.3 Composition Containing from 5 to 10 percent organic matter as determined by the topsoil composition tests of the Organic Carbon, 6A, Chemical Analysis Method described in DOA SSIR 42. Maximum particle size, 3/4 inch, with SECTION 32 92 19 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% maximum 3 percent retained on 1/4 inch screen. The pH must be tested in accordance with ASTM D4972. Topsoil must be free of sticks, stones, roots, and other debris and objectionable materials. Other components must conform to the following limits: Silt 25-50 percent Clay 10-30 percent Sand 20-35 percent pH 5.5 to 7.0 Soluble Salts 600 ppm maximum 2.3 SOIL CONDITIONERS Add conditioners to topsoil as required to bring into compliance with "composition" standard for topsoil as specified herein. 2.3.1 Lime Commercial grade hydrate limestone containing a calcium carbonate equivalent (C.C.E.) as specified in ASTM C602 of not less than 80 percent. 2.3.2 Aluminum Sulfate Commercial grade. 2.3.3 Sulfur 100 percent elemental 2.3.4 Iron 100 percent elemental 2.3.5 Peat Natural product of peat moss derived from a freshwater site and conforming to ASTM D4427. Shred and granulate peat to pass a 1/2 inch mesh screen and condition in storage pile for minimum 6 months after excavation. 2.3.6 Sand Clean and free of materials harmful to plants. 2.3.7 Perlite Horticultural grade. 2.3.8 Composted Derivatives Ground bark, nitrolized sawdust, humus or other green wood waste material free of stones, sticks, and soil stabilized with nitrogen and having the following properties: SECTION 32 92 19 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.3.8.1 Particle Size Minimum percent by weight passing: No. 4 mesh screen 95 No. 8 mesh screen 80 2.3.8.2 Nitrogen Content Minimum percent based on dry weight: Fir Sawdust 0.7 Fir or Pine Bark 1.0 2.3.9 Gypsum Coarsely ground gypsum comprised of calcium sulfate dihydrate 80 percent, calcium 18 percent, sulfur 14 percent; minimum 96 percent passing through 20 mesh screen, 100 percent passing thru 16 mesh screen. 2.3.10 Calcined Clay Calcined clay must be granular particles produced from montmorillonite clay calcined to a minimum temperature of 1200 degrees F. Gradation: A minimum 90 percent must pass a No. 8 sieve; a minimum 99 percent must be retained on a No. 60 sieve; and material passing a No. 100 sieve must not exceed 2 percent. Bulk density: A maximum 40 pounds per cubic foot. 2.4 FERTILIZER 2.4.1 Granular Fertilizer Organic and synthetic, granular controlled release fertilizer: Apply fertilizer/Lime at rates as determined by laboratory soil analysis of soils at the job site. In the absence of the soil analysis, apply soil amendments at the rates indicated in steps 2 and 3. 1. Area will be tilled to 4 inch depth 2. Apply lime at 70 pounds per 1000 square feet, or 1.5 tons per acre 3. Apply 10-20-20 at a rate of 850 pounds per acre or 20 pounds per 1000 square feet. The fertilizer should be either slow time release or applied in two applications, half at time of planting and the second half after permanent seed germinates. 4. The lime and fertilizer will be worked into the top 2 to 4 inches of soil prior to seeding. 5. Seed Mix and Rate 2.4.2 Hydroseeding Fertilizer Controlled release fertilizer, to use with hydroseeding and composed of pills coated with plastic resin to provide a continuous release of nutrients for at least 6 months. SECTION 32 92 19 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Apply fertilizer/Lime at rates as determined by laboratory soil analysis of soils at the job site. In the absence of the soil analysis, apply soil amendments at the rates indicated in steps 2 and 3. 1. Area will be tilled to 4 inch depth 2. Apply lime at 70 pounds per 1000 square feet, or 1.5 tons per acre 3. Apply 10-20-20 at a rate of 850 pounds per acre or 20 pounds per 1000 square feet. The fertilizer should be either slow time release or applied in two applications, half at time of planting and the second half after permanent seed germinates. 4. The lime and fertilizer will be worked into the top 2 to 4 inches of soil prior to seeding. 5. Seed Mix and Rate 2.5 MULCH Mulch must be free from noxious weeds, mold, and other deleterious materials. 2.5.1 Straw Stalks from oats, wheat, rye, barley, or rice. Furnish in air-dry condition and of proper consistency for placing with commercial mulch blowing equipment. Straw must contain no fertile seed. 2.5.2 Hay Air-dry condition and of proper consistency for placing with commercial mulch blowing equipment. Hay must be sterile, containing no fertile seed. 2.5.3 Wood Cellulose Fiber Mulch Use recovered materials of either paper-based (100 percent post-consumer content) or wood-based (100 percent total recovered content) hydraulic mulch. Processed to contain no growth or germination-inhibiting factors and dyed an appropriate color to facilitate visual metering of materials application. Composition on air-dry weight basis: 9 to 15 percent moisture, pH range from 5.5 to 8.2. Use with hydraulic application of grass seed and fertilizer. 2.6 WATER Source of water must be approved by Contracting Officer and of suitable quality for irrigation, containing no elements toxic to plant life. 2.7 EROSION CONTROL MATERIALS Erosion control material must conform to the following: 2.7.1 Erosion Control Blanket 100 percent agricultural straw or 70 percent agricultural straw/30 percent coconut fiber matrix stitched with a degradable nettings, designed to degrade within 12 months. SECTION 32 92 19 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.7.2 Erosion Control Fabric Fabric must be knitted construction of polypropylene yarn with uniform mesh openings 3/4 to 1 inch square with strips of biodegradable paper. Filler paper strips must have a minimum life of 6 months. 2.7.3 Erosion Control Net Net must be heavy, twisted jute mesh, weighing approximately 1.22 pounds per linear yard and 4 feet wide with mesh openings of approximately one inch square. 2.7.4 Erosion Control Material Anchors Erosion control anchors must be as recommended by the manufacturer. PART 3 EXECUTION 3.1 PREPARATION 3.1.1 EXTENT OF WORK Provide soil preparation prior to planting (including soil conditioners as required), fertilizing, seeding, and surface topdressing of all newly graded finished earth surfaces, unless indicated otherwise, and at all areas inside or outside the limits of construction that are disturbed by the Contractor's operations. 3.1.1.1 Topsoil Provide 4 inches of topsoil to meet indicated finish grade. After areas have been brought to indicated finish grade, incorporate fertilizer pH adjusters soil conditioners into soil a minimum depth of 4 inches by disking, harrowing, tilling or other method approved by the Contracting Officer. Remove debris and stones larger than 3/4 inch in any dimension remaining on the surface after finish grading. Correct irregularities in finish surfaces to eliminate depressions. Protect finished topsoil areas from damage by vehicular or pedestrian traffic. 3.1.1.2 Soil Conditioner Application Rates Apply soil conditioners at rates as determined by laboratory soil analysis of the soils at the job site. 3.1.1.3 Fertilizer Application Rates Apply fertilizer at rates as determined by laboratory soil analysis of the soils at the job site. 3.2 SEEDING 3.2.1 Seed Application Seasons and Conditions Immediately before seeding, restore soil to proper grade. Do not seed when ground is muddy frozen snow covered or in an unsatisfactory condition for seeding. If special conditions exist that may warrant a variance in the above seeding dates or conditions, submit a written request to the Contracting Officer stating the special conditions and proposed variance. SECTION 32 92 19 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Apply seed within twenty four hours after seedbed preparation. Sow seed by approved sowing equipment. Sow one-half the seed in one direction, and sow remainder at right angles to the first sowing. 3.2.2 Seed Application Method Seeding method must be hydroseeding. 3.2.2.1 Hydroseeding First, mix water and fiber. Wood cellulose fiber, paper fiber, or recycled paper must be applied as part of the hydroseeding operation. Fiber must be added at 1,000 pounds, dry weight, per acre. Then add and mix seed and fertilizer to produce a homogeneous slurry. When hydraulically sprayed on the ground, material must form a blotter like cover impregnated uniformly with grass seed. Spread with one application with no second application of mulch. 3.2.3 Mulching 3.2.3.1 Hay or Straw Mulch Hay or straw mulch must be spread uniformly at the rate of 2 tons per acre. Mulch must be spread by hand, blower-type mulch spreader, or other approved method. Mulching must be started on the windward side of relatively flat areas or on the upper part of steep slopes, and continued uniformly until the area is covered. The mulch must not be bunched or clumped. Sunlight must not be completely excluded from penetrating to the ground surface. All areas installed with seed must be mulched on the same day as the seeding. Mulch must be anchored immediately following spreading. 3.2.3.2 Mechanical Anchor Mechanical anchor must be a V-type-wheel land packer; a scalloped-disk land packer designed to force mulch into the soil surface; or other suitable equipment. 3.2.3.3 Asphalt Adhesive Tackifier Asphalt adhesive tackifier must be sprayed at a rate between 10 to 13 gallons per 1000 square feet. Sunlight must not be completely excluded from penetrating to the ground surface. 3.2.3.4 Non-Asphaltic Tackifier Hydrophilic colloid must be applied at the rate recommended by the manufacturer, using hydraulic equipment suitable for thoroughly mixing with water. A uniform mixture must be applied over the area. 3.2.3.5 Asphalt Adhesive Coated Mulch Hay or straw mulch may be spread simultaneously with asphalt adhesive applied at a rate between 10 to 13 gallons per 1000 square feet, using power mulch equipment which must be equipped with suitable asphalt pump and nozzle. The adhesive-coated mulch must be applied evenly over the surface. Sunlight must not be completely excluded from penetrating to the ground surface. SECTION 32 92 19 Page 8 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.2.4 Rolling Immediately after seeding, firm entire area except for slopes in excess of 3 to 1 with a roller not exceeding 90 pounds for each foot of roller width. If seeding is performed with cultipacker-type seeder or by hydroseeding, rolling may be eliminated. 3.2.5 Erosion Control Material Install in accordance with manufacturer's instructions, where indicated or as directed by the Contracting Officer. 3.2.6 Watering Start watering areas seeded as required by temperature and wind conditions. Apply water at a rate sufficient to insure thorough wetting of soil to a depth of 2 inches without run off. During the germination process, seed is to be kept actively growing and not allowed to dry out. 3.3 PROTECTION OF TURF AREAS Immediately after turfing, protect area against traffic and other use. 3.4 RENOVATION OF EXISTING TURF AREA 3.4.1 Aeration Upon completion of weed eradication operations and Contracting Officer's approval to proceed, aerate turf areas indicated, by approved device. Core, by pulling soil plugs, to a minimum depth of 3 inches. Leave all soil plugs, that are produced, in the turf area. Remove all debris generated during this operation off site. After aeration operations are complete, topdress entire area 1/4 inch depth with the following mixture: 10 percent sand 20 percent humus 10 percent gypsum 40 percent organic fertilizer 20 percent synthetic fertilizer Blend all parts of topdressing mixture to a uniform consistency throughout. Keep clean at all times at least one paved pedestrian access route and one paved vehicular access route to each building. Clean all soil plugs off of other paving when work is complete. 3.4.2 Vertical Mowing Upon completion of aerating operation and Contracting Officer's approval to proceed, vertical mow turf areas indicated, by approved device, to a depth of 1/4 inch above existing soil level, to reduce thatch build-up, grain, and surface compaction. Keep clean at all times at least one paved pedestrian access route and one paved vehicular access route to each building. Clean other paving when work is complete. Remove all debris generated during this operation off site. SECTION 32 92 19 Page 9 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.4.3 Dethatching Upon completion of aerating operation and Contracting Officer's approval to proceed, dethatch turf areas indicated, by approved device, to a depth of 1/4 inch below existing soil level, to reduce thatch build-up, grain, and surface compaction. Keep clean at all times at least one paved pedestrian access route and one paved vehicular access route to each building. Clean other paving when work is complete. Remove all debris generated during this operation off site. 3.4.4 Overseeding Apply seed in accordance with and at rates indicated in applicable portions of paragraph SEED APPLICATION METHOD. 3.5 RESTORATION Restore to original condition existing turf areas which have been damaged during turf installation operations at the Contractor's expense. Keep clean at all times at least one paved pedestrian access route and one paved vehicular access route to each building. Clean other paving when work in adjacent areas is complete. -- End of Section -- SECTION 32 92 19 Page 10 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 32 92 23 SODDING 04/06 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. ASTM INTERNATIONAL (ASTM) ASTM C602 (2013a) Agricultural Liming Materials ASTM D4427 (2013) Peat Samples by Laboratory Testing ASTM D4972 (2013) pH of Soils TURFGRASS PRODUCERS INTERNATIONAL (TPI) TPI GSS (1995) Guideline Specifications to Turfgrass Sodding U.S. DEPARTMENT OF AGRICULTURE (USDA) DOA SSIR 42 (1996) Soil Survey Investigation Report No. 42, Soil Survey Laboratory Methods Manual, Version 3.0 1.2 DEFINITIONS 1.2.1 Stand of Turf 100 percent ground cover of the established species. 1.3 RELATED REQUIREMENTS Section 31 00 00 EARTHWORK, Section 32 92 19 SEEDING, and Section 32 05 33 LANDSCAPE ESTABLISHMENT applies to this section for pesticide use and plant establishment requirements, with additions and modifications herein. 1.4 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability Notebook, in conformance with Section 01 33 29 SUSTAINABILITY. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-03 Product Data Fertilizer SECTION 32 92 23 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Include physical characteristics, and recommendations. SD-06 Test Reports Topsoil composition tests (reports and recommendations). SD-07 Certificates Nursery or Sod farm certification for sods. Indicate type of sod in accordance with TPI GSS. 1.5 DELIVERY, STORAGE, AND HANDLING 1.5.1 Delivery 1.5.1.1 Sod Protection Protect from drying out and from contamination during delivery, on-site storage, and handling. 1.5.1.2 Fertilizer Gypsum Sulfur Iron and Lime Delivery Deliver to the site in original, unopened containers bearing manufacturer's chemical analysis, name, trade name, trademark, and indication of conformance to state and federal laws. Instead of containers, fertilizer, gypsum, sulphur, iron, and lime may be furnished in bulk with certificate indicating the above information. 1.5.2 Storage 1.5.2.1 Sod Storage Lightly sprinkle with water, cover with moist burlap, straw, or other approved covering; and protect from exposure to wind and direct sunlight until planted. Provide covering that will allow air to circulate so that internal heat will not develop. Do not store sod longer than 24 hours. Do not store directly on concrete or bituminous surfaces. 1.5.2.2 Topsoil Prior to stockpiling topsoil, treat growing vegetation with application of appropriate specified non-selective herbicide. Clear and grub existing vegetation three to four weeks prior to stockpiling topsoil. 1.5.2.3 Handling Do not drop or dump materials from vehicles. 1.6 TIME RESTRICTIONS AND PLANTING CONDITIONS 1.6.1 Restrictions Do not plant when the ground is frozen, snow covered, muddy, or when air temperature exceeds 90 degrees Fahrenheit. SECTION 32 92 23 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 1.7 TIME LIMITATIONS 1.7.1 Sod Place sod a maximum of thirty six hours after initial harvesting, in accordance with TPI GSS as modified herein. PART 2 PRODUCTS 2.1 SODS 2.1.1 Classification Nursery grown, certified as classified in the TPI GSS. Machine cut sod at a uniform thickness of 3/4 inch within a tolerance of 1/4 inch, excluding top growth and thatch. Each individual sod piece shall be strong enough to support its own weight when lifted by the ends. Broken pads, irregularly shaped pieces, and torn or uneven ends will be rejected.Wood pegs and wire staples for anchorage shall be as recommended by sod supplier. 2.1.2 Purity Sod species shall be genetically pure, free of weeds, pests, and disease. 2.1.3 Planting Dates Lay sod from 1 March to 31 August for warm season spring planting and from 1 September to 28 February for cool season fall planting. 2.1.4 Composition 2.1.4.1 Proportion Proportion grass species as follows. "Cool Season": planted between 1 September and 28 February 50 pounds per acre Winter Wheat (Triticum spelta). NO RYE GRASS. 25 pounds per acre common Bermuda (Cynodon dactylon), hulled 25 pounds per acre common Bermuda (Cynodon dactylon), unhulled "Warm Season": planted between 1 March and 31 August 50 pounds per acre German (Setaria italica), Brown Top (Setaria italica), or Fox Tail Millet (Brachiaria ramosum) 50 pounds per acre common Bermuda (Cynodon dactylon), hulled 2.2 TOPSOIL 2.2.1 On-Site Topsoil Surface soil stripped and stockpiled on site and modified as necessary to meet the requirements specified for topsoil in paragraph entitled "Composition." When available topsoil shall be existing surface soil stripped and stockpiled on-site in accordance with Section 31 00 00 EARTHWORK. 2.2.2 Off-Site Topsoil Conform to requirements specified in paragraph entitled "Composition." SECTION 32 92 23 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Additional topsoil shall be furnished by the Contractor. 2.2.3 Composition Containing from 5 to 10 percent organic matter as determined by the topsoil composition tests of the Organic Carbon, 6A, Chemical Analysis Method described in DOA SSIR 42. Maximum particle size, 3/4 inch, with maximum 3 percent retained on 1/4 inch screen. The pH shall be tested in accordance with ASTM D4972. Topsoil shall be free of sticks, stones, roots, and other debris and objectionable materials. Other components shall conform to the following limits: Silt 25-50 percent Clay 10-30 percent Sand 20-35 percent pH 5.5 to 7.0 Soluble Salts 600 ppm maximum 2.3 SOIL CONDITIONERS Add conditioners to topsoil as required to bring into compliance with "composition" standard for topsoil as specified herein. 2.3.1 Lime Commercial grade hydrate limestone containing a calcium carbonate equivalent (C.C.E.) as specified in ASTM C602 of not less than 80 percent. 2.3.2 Aluminum Sulfate Commercial grade. 2.3.3 Sulfur 100 percent elemental 2.3.4 Iron 100 percent elemental 2.3.5 Peat Natural product of peat moss derived from a freshwater site and conforming to ASTM D4427. Shred and granulate peat to pass a 1/2 inch mesh screen and condition in storage pile for minimum 6 months after excavation. 2.3.6 Sand Clean and free of materials harmful to plants. SECTION 32 92 23 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.3.7 Perlite Horticultural grade. 2.3.8 Composted Derivatives Ground bark, nitrolized sawdust, humus or other green wood waste material free of stones, sticks, and soil stabilized with nitrogen and having the following properties: 2.3.8.1 Particle Size Minimum percent by weight passing: No. 4 mesh screen 95 No. 8 mesh screen 80 2.3.8.2 Nitrogen Content Minimum percent based on dry weight: Fir Sawdust 0.7 Fir or Pine Bark 1.0 2.3.9 Gypsum Coarsely ground gypsum comprised of calcium sulfate dihydrate 91 percent, calcium 22 percent, sulfur 17 percent; minimum 96 percent passing through 20 mesh screen, 100 percent passing thru 16 mesh screen. 2.3.10 Calcined Clay Calcined clay shall be granular particles produced from montmorillonite clay calcined to a minimum temperature of 1200 degrees F. Gradation: A minimum 90 percent shall pass a No. 8 sieve; a minimum 99 percent shall be retained on a No. 60 sieve; and a maximum 2 percent shall pass a No. 100 sieve. Bulk density: A maximum 40 pounds per cubic foot. 2.4 FERTILIZER 2.4.1 Granular Fertilizer Apply fertilizer/lime at rates as determined by laboratory soils analysis of soils at the job site. In the absence of the soils analysis, apply lime at 70 pounds per 1,000 square feet, or 1.5 tons per acre, and 10-20-20 fertilizer at a rate of 750 pounds per acre or 20 pounds per square feet. 2.5 WATER Source of water shall be approved by Contracting Officer and of suitable quality for irrigation containing no element toxic to plant life. PART 3 EXECUTION 3.1 PREPARATION 3.1.1 Extent Of Work Provide soil preparation (including soil conditioners), fertilizing, and SECTION 32 92 23 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% sodding of all newly graded finished earth surfaces, unless indicated otherwise, and at all areas inside or outside the limits of construction that are disturbed by the Contractor's operations. 3.1.2 Soil Preparation Provide 4 inches of topsoil to meet indicated finish grade. After areas have been brought to indicated finish grade, incorporate fertilizer pH adjusters soil conditioners into soil a minimum depth of 4 inches by disking, harrowing, tilling or other method approved by the Contracting Officer. Remove debris and stones larger than 3/4 inch in any dimension remaining on the surface after finish grading. Correct irregularities in finish surfaces to eliminate depressions. Protect finished topsoil areas from damage by vehicular or pedestrian traffic. 3.1.2.1 Soil Conditioner Application Rates Apply soil conditioners at rates as determined by laboratory soil analysis of the soils at the job site. 3.1.2.2 Fertilizer Application Rates Apply fertilizer at rates as determined by laboratory soil analysis of the soils at the job site. 3.2 SODDING 3.2.1 Finished Grade and Topsoil Prior to the commencement of the sodding operation, the Contractor shall verify that finished grades are as indicated on drawings; the placing of topsoil, smooth grading, and compaction requirements have been completed in accordance with Section 31 00 00 EARTHWORK. The prepared surface shall be a maximum 1 inch below the adjoining grade of any surfaced area. New surfaces shall be blended to existing areas. The prepared surface shall be completed with a light raking to remove from the surface debris and stones over a minimum 5/8 inch in any dimension. 3.2.2 Placing Place sod a maximum of 36 hours after initial harvesting, in accordance with TPI GSS as modified herein. 3.2.3 Sodding Slopes and Ditches For slopes 2:1 and greater, lay sod with long edge perpendicular to the contour. For V-ditches and flat bottomed ditches, lay sod with long edge perpendicular to flow of water. Anchor each piece of sod with wood pegs or wire staples maximum 2 feet on center. On slope areas, start sodding at bottom of the slope. 3.2.4 Finishing After completing sodding, blend edges of sodded area smoothly into surrounding area. Air pockets shall be eliminated and a true and even surface shall be provided. Frayed edges shall be trimmed and holes and missing corners shall be patched with sod. SECTION 32 92 23 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.2.5 Rolling Immediately after sodding, firm entire area except for slopes in excess of 3 to 1 with a roller not exceeding 90 pounds for each foot of roller width. 3.2.6 Watering Start watering areas sodded as required by daily temperature and wind conditions. Apply water at a rate sufficient to ensure thorough wetting of soil to minimum depth of 6 inches. Run-off, puddling, and wilting shall be prevented. Unless otherwise directed, watering trucks shall not be driven over turf areas. Watering of other adjacent areas or plant material shall be prevented. 3.3 PROTECTION OF TURF AREAS Immediately after turfing, protect area against traffic and other use. 3.4 RESTORATION Restore to original condition existing turf areas which have been damaged during turf installation operations. Keep clean at all times at least one paved pedestrian access route and one paved vehicular access route to each building. Clean other paving when work in adjacent areas is complete. -- End of Section -- SECTION 32 92 23 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% SECTION 33 40 00 STORM DRAINAGE UTILITIES 02/10 PART 1 GENERAL 1.1 REFERENCES The publications listed below form a part of this specification to the extent referenced. The publications are referred to within the text by the basic designation only. AMERICAN ASSOCIATION OF STATE HIGHWAY AND TRANSPORTATION OFFICIALS (AASHTO) AASHTO MP 20 (2013; R 2017) Standard Specification for Steel-Reinforced Polyethylene (PE) Ribbed Pipe, 300- to 1500-mm (12- to 60-in) Diameter ASTM INTERNATIONAL (ASTM) ASTM A123/A123M (2017) Standard Specification for Zinc (Hot-Dip Galvanized) Coatings on Iron and Steel Products ASTM A48/A48M (2003; R 2012) Standard Specification for Gray Iron Castings ASTM A536 (1984; R 2014) Standard Specification for Ductile Iron Castings ASTM A929/A929M (2017) Standard Specification for Steel Sheet, Metallic-Coated by the Hot-Dip Process for Corrugated Steel Pipe ASTM B26/B26M (2014; E 2015) Standard Specification for Aluminum-Alloy Sand Castings ASTM C1103 (2014) Standard Practice for Joint Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines ASTM C139 (2017) Standard Specification for Concrete Masonry Units for Construction of Catch Basins and Manholes ASTM C1433 (2016b) Standard Specification for Precast Reinforced Concrete Monolithic Box Sections for Culverts, Storm Drains, and Sewers ASTM C231/C231M (2017a) Standard Test Method for Air Content of Freshly Mixed Concrete by the Pressure Method SECTION 33 40 00 Page 1 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% ASTM C270 (2014a) Standard Specification for Mortar for Unit Masonry ASTM C425 (2004; R 2013) Standard Specification for Compression Joints for Vitrified Clay Pipe and Fittings ASTM C443 (2012; R 2017) Standard Specification for Joints for Concrete Pipe and Manholes, Using Rubber Gaskets ASTM C478 (2018) Standard Specification for Circular Precast Reinforced Concrete Manhole Sections ASTM C76 (2015) Standard Specification for Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe ASTM C828 (2011) Low-Pressure Air Test of Vitrified Clay Pipe Lines ASTM C877 (2008) External Sealing Bands for Concrete Pipe, Manholes, and Precast Box Sections ASTM C923 (2008; R 2013; E 2016) Standard Specification for Resilient Connectors Between Reinforced Concrete Manhole Structures, Pipes and Laterals ASTM C969 (2017) Standard Practice for Infiltration and Exfiltration Acceptance Testing of Installed Precast Concrete Pipe Sewer Lines ASTM C990 (2009; R 2014) Standard Specification for Joints for Concrete Pipe, Manholes and Precast Box Sections Using Preformed Flexible Joint Sealants ASTM D1056 (2014) Standard Specification for Flexible Cellular Materials - Sponge or Expanded Rubber ASTM D1171 (2016; E 2016) Standard Test Method for Rubber Deterioration - Surface Ozone Cracking Outdoors (Triangular Specimens) ASTM D1751 (2004; E 2013; R 2013) Standard Specification for Preformed Expansion Joint Filler for Concrete Paving and Structural Construction (Nonextruding and Resilient Bituminous Types) ASTM D1752 (2004a; R 2013) Standard Specification for Preformed Sponge Rubber Cork and Recycled PVC Expansion ASTM D2321 (2014; E 2014) Standard Practice for Underground Installation of Thermoplastic SECTION 33 40 00 Page 2 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% Pipe for Sewers and Other Gravity-Flow Applications ASTM D2729 (2017) Standard Specification for Poly(Vinyl Chloride) (PVC) Sewer Pipe and Fittings ASTM F1417 (2011a) Standard Test Method for Installation Acceptance of Plastic Gravity Sewer Lines Using Low Pressure Air ASTM F2562/F2562M (2015) Specification for Steel Reinforced Thermoplastic Ribbed Pipe and Fittings for Non-Pressure Drainage and Sewerage ASTM F2736 (2013; E 2014) Standard Specification for 6 to 30 in. (152 To 762 mm) Polypropylene (PP) Corrugated Single Wall Pipe And Double Wall Pipe ASTM F2764/F2764M (2017; E 2017) Standard Specification for 6 to 60 in. 150 to 1500 mm Polypropylene (PP) Corrugated Double and Triple Wall Pipe and Fittings for Non-Pressure Sanitary Sewer Applications ASTM F2881 (2011) Standard Specification for 12 to 60 in. (300 to 1500 mm) Polypropylene (PP) Dual Wall Pipe and Fittings for Non-Pressure Storm Sewer Applications 1.2 SUBMITTALS Government approval is required for submittals with a "G" designation; submittals not having a "G" designation are for information only. When used, a designation following the "G" designation identifies the office that will review the submittal for the Government. Submittals with an "S" are for inclusion in the Sustainability eNotebook, in conformance to Section 01 33 29 SUSTAINABILITY REPORTING. Submit the following in accordance with Section 01 33 00 SUBMITTAL PROCEDURES: SD-07 Certificates Resin Certification Oil Resistant Gasket Frame and Cover for Gratings Post-Installation Inspection Report 1.3 DELIVERY, STORAGE, AND HANDLING 1.3.1 Delivery and Storage Materials delivered to site shall be inspected for damage, unloaded, and stored with a minimum of handling. Materials shall not be stored directly on the ground. The inside of pipes and fittings shall be kept free of dirt and debris. Before, during, and after installation, plastic pipe and SECTION 33 40 00 Page 3 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% fittings shall be protected from any environment that would result in damage or deterioration to the material. Keep a copy of the manufacturer's instructions available at the construction site at all times and follow these instructions unless directed otherwise by the Contracting Officer. Solvents, solvent compounds, lubricants, elastomeric gaskets, and any similar materials required to install plastic pipe shall be stored in accordance with the manufacturer's recommendations and shall be discarded if the storage period exceeds the recommended shelf life. Solvents in use shall be discarded when the recommended pot life is exceeded. 1.3.2 Handling Materials shall be handled in a manner that ensures delivery to the trench in sound, undamaged condition. Pipe shall be carried to the trench, not dragged. PART 2 PRODUCTS 2.1 PIPE FOR CULVERTS AND STORM DRAINS Pipe for culverts and storm drains shall be of the sizes indicated and shall conform to the requirements specified. 2.1.1 Concrete Pipe Manufactured in accordance with and conforming to ASTM C76, Class III or V. 2.1.2 Poly Vinyl Chloride (PVC) Pipe Submit the pipe manufacturer's resin certification, indicating the cell classification of PVC used to manufacture the pipe, prior to installation of the pipe. 2.1.3 Steel Reinforced Polyethylene (SRPE) Pipe SRPE pipe will meet the requirements of ASTM F2562/F2562M 8 - 120 inch diameter pipe and AASHTO MP 20 (12 - 60 inch diameter pipe). 2.1.4 Polypropylene (PP) Pipe Double wall and triple wall pipe with a diameter of 12 to 60 inches shall meet the requirements of ASTM F2736, ASTM F2764/F2764M, or ASTM F2881. 2.2 PERFORATED PIPING 2.2.1 Polyvinyl Chloride (PVC) Pipe ASTM D2729. 2.2.2 Polypropylene (PP) Pipe ASTM F2881, Class II perforation patterns. 2.3 DRAINAGE STRUCTURES 2.3.1 Flared End Sections Sections shall be of a standard design fabricated from zinc coated steel SECTION 33 40 00 Page 4 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% sheets meeting requirements of ASTM A929/A929M. 2.3.2 Precast Reinforced Concrete Box Manufactured in accordance with and conforming to ASTM C1433. 2.4 MISCELLANEOUS MATERIALS 2.4.1 Concrete Unless otherwise specified, concrete and reinforced concrete shall conform to the requirements for 3,500 psi concrete under Section 03 30 00 CAST-IN-PLACE CONCRETE . The concrete mixture shall have air content by volume of concrete, based on measurements made immediately after discharge from the mixer, of 5 to 7 percent when maximum size of coarse aggregate exceeds 1-1/2 inches. Air content shall be determined in accordance with ASTM C231/C231M. The concrete covering over steel reinforcing shall not be less than 1 inch thick for covers and not less than 1-1/2 inches thick for walls and flooring. Concrete covering deposited directly against the ground shall have a thickness of at least 3 inches between steel and ground. Expansion-joint filler material shall conform to ASTM D1751, or ASTM D1752, or shall be resin-impregnated fiberboard conforming to the physical requirements of ASTM D1752. 2.4.2 Mortar Mortar for pipe joints, connections to other drainage structures, and brick or block construction shall conform to ASTM C270, Type M, except that the maximum placement time shall be 1 hour. The quantity of water in the mixture shall be sufficient to produce a stiff workable mortar but in no case shall exceed 1 gallons of water per sack of cement. Water shall be clean and free of harmful acids, alkalis, and organic impurities. The mortar shall be used within 30 minutes after the ingredients are mixed with water. The inside of the joint shall be wiped clean and finished smooth. The mortar head on the outside shall be protected from air and sun with a proper covering until satisfactorily cured. 2.4.3 Precast Concrete Segmental Blocks Precast concrete segmental block shall conform to ASTM C139, not more than 8 inches thick, not less than 8 inches long, and of such shape that joints can be sealed effectively and bonded with cement mortar. 2.4.4 Precast Reinforced Concrete Manholes Conform to ASTM C478. Joints between precast concrete risers and tops shall be full-bedded in cement mortar and shall be smoothed to a uniform surface on both interior and exterior of the structure or made with flexible watertight, rubber-type gaskets meeting the requirements of paragraph JOINTS. 2.4.5 Prefabricated Corrugated Metal Manholes Manholes shall be of the type and design recommended by the manufacturer. Manholes shall be complete with frames and cover, or frames and gratings. 2.4.6 Frame and Cover for Gratings Submit certification on the ability of frame and cover or gratings to SECTION 33 40 00 Page 5 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% carry the imposed live load. Frame and cover for gratings shall be cast gray iron, ASTM A48/A48M, Class 35B; cast ductile iron, ASTM A536, Grade 65-45-12; or cast aluminum, ASTM B26/B26M, Alloy 356.O-T6. Weight, shape, size, and waterway openings for grates and curb inlets shall be as indicated on the plans. The word "Storm Sewer" shall be stamped or cast into covers so that it is plainly visible. 2.4.7 Joints 2.4.7.1 Flexible Watertight Joints a. Flexible watertight joints shall be made with plastic or rubber-type gaskets for concrete pipe and with factory-fabricated resilient materials for clay pipe. The design of joints and the physical requirements for preformed flexible joint sealants shall conform to ASTM C990, and rubber-type gaskets shall conform to ASTM C443. Factory-fabricated resilient joint materials shall conform to ASTM C425. Gaskets shall have not more than one factory-fabricated splice, except that two factory-fabricated splices of the rubber-type gasket are permitted if the nominal diameter of the pipe being gasketed exceeds 54 inches. b. Rubber gaskets shall comply with the oil resistant gasket requirements of ASTM C443. Certified copies of test results shall be delivered to the Contracting Officer before gaskets or jointing materials are installed. Alternate types of watertight joint may be furnished, if specifically approved. 2.4.7.2 External Sealing Bands Requirements for external sealing bands shall conform to ASTM C877. 2.4.7.3 Flexible Watertight, Gasketed Joints a. Gaskets: When infiltration or exfiltration is a concern for pipe lines, the couplings may be required to have gaskets. The closed-cell expanded rubber gaskets shall be a continuous band approximately 7 inches wide and approximately 3/8 inch thick, meeting the requirements of ASTM D1056, Type 2 A1, and shall have a quality retention rating of not less than 70 percent when tested for weather resistance by ozone chamber exposure, Method B of ASTM D1171. Rubber O-ring gaskets shall be 13/16 inch in diameter for pipe diameters of 36 inches or smaller and 7/8 inch in diameter for larger pipe having 1/2 inch deep end corrugation. Rubber O-ring gaskets shall be 1-3/8 inches in diameter for pipe having 1 inch deep end corrugations. O-rings shall meet the requirements of ASTM C990 or ASTM C443. Preformed flexible joint sealants shall conform to ASTM C990, Type B. b. Connecting Bands: Connecting bands shall be of the type, size and sheet thickness of band, and the size of angles, bolts, rods and lugs as indicated or where not indicated as specified in the applicable standards or specifications for the pipe. Exterior rivet heads in the longitudinal seam under the connecting band shall be countersunk or the rivets shall be omitted and the seam welded. Watertight joints shall be tested and shall meet the test requirements of paragraph HYDROSTATIC TEST ON WATERTIGHT JOINTS. SECTION 33 40 00 Page 6 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 2.4.7.4 PVC Plastic Pipes Joints shall be solvent cement or elastomeric gasket type in accordance with the specification for the pipe and as recommended by the pipe manufacturer. 2.5 STEEL LADDER Steel ladder shall be provided where the depth of the storm drainage structure exceeds 12 feet. These ladders shall be not less than 16 inches in width, with 3/4 inch diameter rungs spaced 12 inches apart. The two stringers shall be a minimum 3/8 inch thick and 2-1/2 inches wide. Ladders and inserts shall be galvanized after fabrication in conformance with ASTM A123/A123M. 2.6 RESILIENT CONNECTORS Flexible, watertight connectors used for connecting pipe to manholes and inlets shall conform to ASTM C923. 2.7 EROSION CONTROL RIP RAP Provide non-erodible rock not exceeding 15 inches in its greatest dimension and choked with sufficient small rocks to provide a dense mass with a minimum thickness of as indicated. PART 3 EXECUTION 3.1 INSTALLATION OF PIPE CULVERTS, STORM DRAINS, AND DRAINAGE STRUCTURES Excavation of trenches, and for appurtenances and backfilling for culverts and storm drains, shall be in accordance with the applicable portions of Section 31 00 00 EARTHWORK and the requirements specified below. 3.1.1 Trenching The width of trenches at any point below the top of the pipe shall be not greater than the outside diameter of the pipe plus 12 inches to permit satisfactory jointing and thorough tamping of the bedding material under and around the pipe. Sheeting and bracing, where required, shall be placed within the trench width as specified, without any overexcavation. Where trench widths are exceeded, redesign with a resultant increase in cost of stronger pipe or special installation procedures will be necessary. Cost of this redesign and increased cost of pipe or installation shall be borne by the Contractor without additional cost to the Government. 3.1.2 Removal of Rock Rock in either ledge or boulder formation shall be replaced with suitable materials to provide a compacted earth cushion having a thickness between unremoved rock and the pipe of at least 8 inches or 1/2 inch for each foot of fill over the top of the pipe, whichever is greater, but not more than three-fourths the nominal diameter of the pipe. Where bell-and-spigot pipe is used, the cushion shall be maintained under the bell as well as under the straight portion of the pipe. Rock excavation shall be as specified and defined in Section 31 00 00 EARTHWORK. SECTION 33 40 00 Page 7 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.1.3 Removal of Unstable Material Where wet or otherwise unstable soil incapable of properly supporting the pipe, as determined by the Contracting Officer, is unexpectedly encountered in the bottom of a trench, such material shall be removed to the depth required and replaced to the proper grade with select granular material, compacted as provided in paragraph BACKFILLING. When removal of unstable material is due to the fault or neglect of the Contractor while performing shoring and sheeting, water removal, or other specified requirements, such removal and replacement shall be performed at no additional cost to the Government. 3.2 BEDDING The bedding surface for the pipe shall provide a firm foundation of uniform density throughout the entire length of the pipe. 3.2.1 Concrete Pipe Requirements When no bedding class is specified or detailed on the drawings, concrete pipe shall be bedded in granular material minimum 4 inch in depth in trenches with soil foundation. Depth of granular bedding in trenches with rock foundation shall be 1/2 inch in depth per foot of depth of fill, minimum depth of bedding shall be 8 inch up to maximum depth of 24 inches. The middle third of the granular bedding shall be loosely placed. Bell holes and depressions for joints shall be removed and formed so entire barrel of pipe is uniformly supported. The bell hole and depressions for the joints shall be not more than the length, depth, and width required for properly making the particular type of joint. 3.2.2 Plastic Pipe Bedding for PVC, PE, SRPE and PP pipe shall meet the requirements of ASTM D2321. Use Class IB or II material for bedding, haunching, and initial backfill. Use Class I, II, or III material for PP pipe bedding, haunching and initial backfill. 3.3 PLACING PIPE Each pipe shall be thoroughly examined before being laid; defective or damaged pipe shall not be used. Plastic pipe, excluding SRPE pipe shall be protected from exposure to direct sunlight prior to laying, if necessary to maintain adequate pipe stiffness and meet installation deflection requirements. Pipelines shall be laid to the grades and alignment indicated. Proper facilities shall be provided for lowering sections of pipe into trenches. Lifting lugs in vertically elongated pipe shall be placed in the same vertical plane as the major axis of the pipe. Pipe shall not be laid in water, and pipe shall not be laid when trench conditions or weather are unsuitable for such work. Diversion of drainage or dewatering of trenches during construction shall be provided as necessary. Deflection of installed flexible pipe shall not exceed the following limits: TYPE OF PIPE MAXIMUM ALLOWABLE DEFLECTION (percent) Corrugated Steel and Aluminum 5 SECTION 33 40 00 Page 8 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% TYPE OF PIPE MAXIMUM ALLOWABLE DEFLECTION (percent) Concrete-Lined Corrugated Steel 3 Plastic (PVC, PE, SRPE, and PP)5 Note post installation requirements of paragraph DEFLECTION TESTING in PART 3 of this specification for all pipe products including deflection testing requirements for flexible pipe. 3.3.1 Concrete, Clay, PVC, Ribbed PVC, Ductile Iron and Cast-Iron Pipe Laying shall proceed upgrade with spigot ends of bell-and-spigot pipe and tongue ends of tongue-and-groove pipe pointing in the direction of the flow. 3.3.2 PE, SRPE, and Dual Wall and Triple Wall PP Pipe Laying shall be with the separate sections joined firmly on a bed shaped to line and grade and shall follow manufacturer's guidelines. 3.4 JOINTING 3.4.1 Concrete and Clay Pipe 3.4.1.1 Cement-Mortar Bell-and-Spigot Joint The first pipe shall be bedded to the established grade line, with the bell end placed upstream. The interior surface of the bell shall be thoroughly cleaned with a wet brush and the lower portion of the bell filled with mortar as required to bring inner surfaces of abutting pipes flush and even. The spigot end of each subsequent pipe shall be cleaned with a wet brush and uniformly matched into a bell so that sections are closely fitted. After each section is laid, the remainder of the joint shall be filled with mortar, and a bead shall be formed around the outside of the joint with sufficient additional mortar. If mortar is not sufficiently stiff to prevent appreciable slump before setting, the outside of the joint shall be wrapped or bandaged with cheesecloth to hold mortar in place. 3.4.1.2 Cement-Mortar Oakum Joint for Bell-and-Spigot Pipe A closely twisted gasket shall be made of jute or oakum of the diameter required to support the spigot end of the pipe at the proper grade and to make the joint concentric. Joint packing shall be in one piece of sufficient length to pass around the pipe and lap at top. This gasket shall be thoroughly saturated with neat cement grout. The bell of the pipe shall be thoroughly cleaned with a wet brush, and the gasket shall be laid in the bell for the lower third of the circumference and covered with mortar. The spigot of the pipe shall be thoroughly cleaned with a wet brush, inserted in the bell, and carefully driven home. A small amount of mortar shall be inserted in the annular space for the upper two-thirds of the circumference. The gasket shall be lapped at the top of the pipe and driven home in the annular space with a caulking tool. The remainder of the annular space shall be filled completely with mortar and beveled at an angle of approximately 45 degrees with the outside of the bell. If mortar SECTION 33 40 00 Page 9 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% is not sufficiently stiff to prevent appreciable slump before setting, the outside of the joint thus made shall be wrapped with cheesecloth. Placing of this type of joint shall be kept at least five joints behind laying operations. 3.4.1.3 Cement-Mortar Diaper Joint for Bell-and-Spigot Pipe The pipe shall be centered so that the annular space is uniform. The annular space shall be caulked with jute or oakum. Before caulking, the inside of the bell and the outside of the spigot shall be cleaned. a. Diaper Bands: Diaper bands shall consist of heavy cloth fabric to hold grout in place at joints and shall be cut in lengths that extend one-eighth of the circumference of pipe above the spring line on one side of the pipe and up to the spring line on the other side of the pipe. Longitudinal edges of fabric bands shall be rolled and stitched around two pieces of wire. Width of fabric bands shall be such that after fabric has been securely stitched around both edges on wires, the wires will be uniformly spaced not less than 8 inches apart. Wires shall be cut into lengths to pass around pipe with sufficient extra length for the ends to be twisted at top of pipe to hold the band securely in place; bands shall be accurately centered around lower portion of joint. b. Grout: Grout shall be poured between band and pipe from the high side of band only, until grout rises to the top of band at the spring line of pipe, or as nearly so as possible, on the opposite side of pipe, to ensure a thorough sealing of joint around the portion of pipe covered by the band. Silt, slush, water, or polluted mortar grout forced up on the lower side shall be forced out by pouring, and removed. c. Remainder of Joint: The remaining unfilled upper portion of the joint shall be filled with mortar and a bead formed around the outside of this upper portion of the joint with a sufficient amount of additional mortar. The diaper shall be left in place. Placing of this type of joint shall be kept at least five joints behind actual laying of pipe. No backfilling around joints shall be done until joints have been fully inspected and approved. 3.4.1.4 Cement-Mortar Tongue-and-Groove Joint The first pipe shall be bedded carefully to the established grade line with the groove upstream. A shallow excavation shall be made underneath the pipe at the joint and filled with mortar to provide a bed for the pipe. The grooved end of the first pipe shall be thoroughly cleaned with a wet brush, and a layer of soft mortar applied to the lower half of the groove. The tongue of the second pipe shall be cleaned with a wet brush; while in horizontal position, a layer of soft mortar shall be applied to the upper half of the tongue. The tongue end of the second pipe shall be inserted in the grooved end of the first pipe until mortar is squeezed out on interior and exterior surfaces. Sufficient mortar shall be used to fill the joint completely and to form a bead on the outside. 3.4.1.5 Cement-Mortar Diaper Joint for Tongue-and-Groove Pipe The joint shall be of the type described for cement-mortar tongue-and-groove joint in this paragraph, except that the shallow excavation directly beneath the joint shall not be filled with mortar until after a gauze or cheesecloth band dipped in cement mortar has been SECTION 33 40 00 Page 10 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% wrapped around the outside of the joint. The cement-mortar bead at the joint shall be at least 1/2 inch, thick and the width of the diaper band shall be at least 8 inches. The diaper shall be left in place. Placing of this type of joint shall be kept at least five joints behind the actual laying of the pipe. Backfilling around the joints shall not be done until the joints have been fully inspected and approved. 3.4.1.6 Plastic Sealing Compound Joints for Tongue-and-Grooved Pipe Sealing compounds shall follow the recommendation of the particular manufacturer in regard to special installation requirements. Surfaces to receive lubricants, primers, or adhesives shall be dry and clean. Sealing compounds shall be affixed to the pipe not more than 3 hours prior to installation of the pipe, and shall be protected from the sun, blowing dust, and other deleterious agents at all times. Sealing compounds shall be inspected before installation of the pipe, and any loose or improperly affixed sealing compound shall be removed and replaced. The pipe shall be aligned with the previously installed pipe, and the joint pulled together. If, while making the joint with mastic-type sealant, a slight protrusion of the material is not visible along the entire inner and outer circumference of the joint when the joint is pulled up, the pipe shall be removed and the joint remade. After the joint is made, all inner protrusions shall be cut off flush with the inner surface of the pipe. If non-mastic-type sealant material is used, the "Squeeze-Out" requirement above will be waived. 3.4.1.7 Flexible Watertight Joints Gaskets and jointing materials shall be as recommended by the particular manufacturer in regard to use of lubricants, cements, adhesives, and other special installation requirements. Surfaces to receive lubricants, cements, or adhesives shall be clean and dry. Gaskets and jointing materials shall be affixed to the pipe not more than 24 hours prior to the installation of the pipe, and shall be protected from the sun, blowing dust, and other deleterious agents at all times. Gaskets and jointing materials shall be inspected before installing the pipe; any loose or improperly affixed gaskets and jointing materials shall be removed and replaced. The pipe shall be aligned with the previously installed pipe, and the joint pushed home. If, while the joint is being made the gasket becomes visibly dislocated the pipe shall be removed and the joint remade. 3.4.1.8 External Sealing Band Joint for Noncircular Pipe Surfaces to receive sealing bands shall be dry and clean. Bands shall be installed in accordance with manufacturer's recommendations. 3.5 DRAINAGE STRUCTURES 3.5.1 Manholes and Inlets Construction shall be of reinforced concrete, plain concrete, brick, precast reinforced concrete, precast concrete segmental blocks, prefabricated corrugated metal, or bituminous coated corrugated metal; complete with frames and covers or gratings; and with fixed galvanized steel ladders where indicated. Pipe studs and junction chambers of prefabricated corrugated metal manholes shall be fully bituminous-coated and paved when the connecting branch lines are so treated. Pipe connections to concrete manholes and inlets shall be made with flexible, watertight connectors. SECTION 33 40 00 Page 11 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.5.2 Walls and Headwalls Construction shall be as indicated. 3.6 STEEL LADDER INSTALLATION Ladder shall be adequately anchored to the wall by means of steel inserts spaced not more than 6 feet vertically, and shall be installed to provide at least 6 inches of space between the wall and the rungs. The wall along the line of the ladder shall be vertical for its entire length. 3.7 BACKFILLING 3.7.1 Backfilling Pipe in Trenches After the pipe has been properly bedded, selected material from excavation or borrow, at a moisture content that will facilitate compaction, shall be placed along both sides of pipe in layers not exceeding 6 inches in compacted depth. The backfill shall be brought up evenly on both sides of pipe for the full length of pipe. The fill shall be thoroughly compacted under the haunches of the pipe. Each layer shall be thoroughly compacted with mechanical tampers or rammers. This method of filling and compacting shall continue until the fill has reached an elevation equal to the midpoint (spring line) of concrete pipe or has reached an elevation of at least 12 inches above the top of the pipe for flexible pipe. The remainder of the trench shall be backfilled and compacted by spreading and rolling or compacted by mechanical rammers or tampers in layers not exceeding 6 inches. Tests for density shall be made as necessary to ensure conformance to the compaction requirements specified below. Where it is necessary, in the opinion of the Contracting Officer, that sheeting or portions of bracing used be left in place, the contract will be adjusted accordingly. Untreated sheeting shall not be left in place beneath structures or pavements. 3.7.2 Backfilling Pipe in Fill Sections For pipe placed in fill sections, backfill material and the placement and compaction procedures shall be as specified below. The fill material shall be uniformly spread in layers longitudinally on both sides of the pipe, not exceeding 6 inches in compacted depth, and shall be compacted by rolling parallel with pipe or by mechanical tamping or ramming. Prior to commencing normal filling operations, the crown width of the fill at a height of 12 inches above the top of the pipe shall extend a distance of not less than twice the outside pipe diameter on each side of the pipe or 12 feet, whichever is less. After the backfill has reached at least 12 inches above the top of the pipe, the remainder of the fill shall be placed and thoroughly compacted in layers not exceeding 6 inches. Use select granular material for this entire region of backfill for flexible pipe installations. 3.7.3 Movement of Construction Machinery When compacting by rolling or operating heavy equipment parallel with the pipe, displacement of or injury to the pipe shall be avoided. Movement of construction machinery over a culvert or storm drain at any stage of construction shall be at the Contractor's risk. Any damaged pipe shall be repaired or replaced. SECTION 33 40 00 Page 12 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.7.4 Compaction 3.7.4.1 General Requirements Cohesionless materials include gravels, gravel-sand mixtures, sands, and gravelly sands. Cohesive materials include clayey and silty gravels, gravel-silt mixtures, clayey and silty sands, sand-clay mixtures, clays, silts, and very fine sands. When results of compaction tests for moisture-density relations are recorded on graphs, cohesionless soils will show straight lines or reverse-shaped moisture-density curves, and cohesive soils will show normal moisture-density curves. 3.7.4.2 Minimum Density Backfill over and around the pipe and backfill around and adjacent to drainage structures shall be compacted at the approved moisture content to the following applicable minimum density, which will be determined as specified below. a. Under airfield and heliport pavements, paved roads, streets, parking areas, and similar-use pavements including adjacent shoulder areas, the density shall be not less than 90 percent of maximum density for cohesive material and 95 percent of maximum density for cohesionless material, up to the elevation where requirements for pavement subgrade materials and compaction shall control. b. Under unpaved or turfed traffic areas, density shall not be less than 90 percent of maximum density for cohesive material and 95 percent of maximum density for cohesionless material. c. Under nontraffic areas, density shall be not less than that of the surrounding material. 3.8 FIELD PAINTING 3.8.1 Cast-Iron Covers, Frames, Gratings, And Steps After installation, clean cast-iron, not buried in masonry or concrete, of mortar, rust, grease, dirt, and other deleterious materials to bare metal and apply a coat of bituminous paint. 3.9 FIELD QUALITY CONTROL 3.9.1 Tests Testing is the responsibility of the Contractor. Perform all testing and retesting at no additional cost to the Government. 3.9.1.1 Leakage Test Lines shall be tested for leakage by low pressure air or water testing or exfiltration tests, as appropriate, prior to completing backfill. Low pressure air testing for vitrified clay pipes shall conform to ASTM C828. Low pressure air testing for concrete pipes shall conform to ASTM C969. Low pressure air testing for plastic pipe shall conform to ASTM F1417. Low pressure air testing procedures for other pipe materials shall use the pressures and testing times prescribed in ASTM C828 or ASTM C969, after consultation with the pipe manufacturer. Testing of individual joints for leakage by low pressure air or water shall conform to ASTM C1103. Prior SECTION 33 40 00 Page 13 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% to exfiltration tests, the trench shall be backfilled up to at least the lower half of the pipe. If required, sufficient additional backfill shall be placed to prevent pipe movement during testing, leaving the joints uncovered to permit inspection. Visible leaks encountered shall be corrected regardless of leakage test results. When the water table is 2 feet or more above the top of the pipe at the upper end of the pipeline section to be tested, infiltration shall be measured using a suitable weir or other device acceptable to the Contracting Officer. An exfiltration test shall be made by filling the line to be tested with water so that a head of at least 2 feet is provided above both the water table and the top of the pipe at the upper end of the pipeline to be tested. The filled line shall be allowed to stand until the pipe has reached its maximum absorption, but not less than 4 hours. After absorption, the head shall be reestablished. The amount of water required to maintain this water level during a 2-hour test period shall be measured. Leakage as measured by the exfiltration test shall not exceed 0.2 gallons per inch in diameter per 100 feet of pipeline per hour. 3.9.1.2 Deflection Testing Conduct deflection test no sooner than 30 days after completion of final backfill and compaction testing. Clean or flush all lines prior to testing. Perform a deflection test on entire length of installed flexible pipeline upon completion of work adjacent to and over the pipeline, including backfilling, placement of fill, grading, paving, placement of concrete, and any other superimposed loads. Deflection of pipe in the installed pipeline under external loads shall not exceed limits in paragraph PLACING PIPE above as percent of the average inside diameter of pipe. Use a laser profiler or mandrel to determine if allowable deflection has been exceeded. 3.9.1.2.1 Laser Profiler Inspect pipe interior with laser profiling equipment. Utilize low barrel distortion video equipment for pipe sizes 48 inches or less. Use a camera with suitable lighting to allow a clear picture of the entire periphery of the pipe interior. Center the camera in the pipe both vertically and horizontally. The camera must be able to pan and tilt to a 90 degree angle with the axis of the pipe rotating 360 degrees. Use equipment to move the camera through the pipe that will not obstruct the camera's view or interfere with proper documentation of the pipe's condition. The video image shall be clear, focused, and relatively free from roll static or other image distortion qualities that would prevent the reviewer from evaluating the condition of the pipe. For initial post installation inspections for pipe sizes larger than 48 inches, a visual inspection shall be completed of the pipe interior. 3.9.2 Inspection 3.9.2.1 Post-Installation Inspection Visually inspect each segment of concrete pipe for alignment, settlement, joint separations, soil migration through the joint, cracks, buckling, bulging and deflection. An engineer must evaluate all defects to determine if any remediation or repair is required. 3.9.2.1.1 Concrete Cracks with a width greater than 0.01 inches. An engineer must evaluate SECTION 33 40 00 Page 14 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% all pipes with cracks with a width greater than 0.01 inches but less than 0.10 inches to determine if any remediation or repair is required. 3.9.2.1.2 Flexible Pipe Check each flexible pipe (PE, PVC, PP, Corregated Steel And Aluminum) for rips, tears, joint separations, soil migration through the joint, cracks, localized bucking, bulges, settlement and alignment. 3.9.2.1.3 Post-Installation Inspection Report The deflection results and final post installation inspection report must include: pipe location identification, equipment used for inspection, inspector name, deviation from design, grade, deviation from line, deflection and deformation of flexible pipe, inspector notes, condition of joints, condition of pipe wall (e.g. distress, cracking, wall damage dents, bulges, creases, tears, holes, etc.). 3.9.2.2 Low Impact Development Inspection Inspect Low Impact Development (LID) features indicated on the design portion of the LID Verification Report. Certify LID features were constructed according to plans and specifications or by submitting as-built drawings in accordance with UFGS 01 78 00 Closeout Submittals. When as-built drawings show deviations to the LID features, document the deviations on the LID Verification Report. 3.9.3 Repair Of Defects 3.9.3.1 Leakage Test When leakage exceeds the maximum amount specified, correct source of excess leakage by replacing damaged pipe and gaskets and retest. 3.9.3.2 Deflection Testing When deflection readings are in excess of the allowable deflection of average inside diameter of pipe are obtained, remove pipe which has excessive deflection and replace with new pipe. Retest 30 days after completing backfill, leakage testing and compaction testing. 3.9.3.3 Inspection Replace pipe or repair defects indicated in the Post-Installation Inspection Report. 3.9.3.3.1 Concrete Replace pipes having cracks with a width greater than 0.1 inches. 3.9.3.3.2 Flexible Pipe Replace pipes having cracks or splits. 3.10 PROTECTION Protect storm drainage piping and adjacent areas from superimposed and external loads during construction. SECTION 33 40 00 Page 15 SOF CIVIL AFFAIRS TEMF W912PM-19-C-0008 PN# 69552 VOL I - 100% 3.11 WARRANTY PERIOD Pipe segments found to have defects during the warranty period must be replaced with new pipe and retested. -- End of Section -- SECTION 33 40 00 Page 16