HomeMy WebLinkAboutNCG190050_CEI Letter_20200116ROY COOPER Governor MICHAEL S. REGAN Secretary S. DANIEL SMITH Director January 17, 2020 NORTH CAROLINA Enytromnental Quality United States Coast Guard Attn: George 0. Fulenwider USCG SFO Ft. Macon Logistics Department Head 2301 East Fort Macon Road Atlantic Beach, NC 28512 Subject: Compliance Evaluation Inspection NPDES General Stormwater Permit NCG190000 Certificate of Coverage NCG190050 USCG SFO FT MACON Carteret County Dear Sir: On January 16, 2020, Brian Lambe from the Wilmington Regional Office of the Division of Energy, Mineral, and Land Resources (DEMLR), conducted a compliance evaluation inspection for USCG SFO FT MACON located in Atlantic Beach, Carteret County, North Carolina. The site drains to Fort Macon Creek, which is currently classified as Class SA HOW Waters in the White Oak River Basin. The following observations were noted during the DEMLR inspection (please see the attached addendum for additional information about your permit): 1) Stormwater Pollution Prevention Plan (SPPP) A Stormwater Pollution Prevention Plan (SPPP) has been developed, recorded, and properly implemented. Yes ■ No ❑ 2) Qualitative Monitorint Qualitative monitoring has been conducted and recorded in accordance with permit requirements. Yes ■ No ❑ 3) Analytical Monitoring Analytical monitoring has been conducted and recorded in accordance with permit requirements. Yes ■ No ❑ Other Observations: Tier relief for copper and zinc is granted for duration of the permit term. Thank you for your assistance and cooperation during this inspection. Please be advised that violations of the NPDES Stormwater General Permit may be subject to a civil penalty assessment of up to $25,000.00 per day for each violation. If you have any questions, comments, or need assistance with understanding any aspect of your permit, please do not hesitate to contact Daniel Sams or me at (910)796-721S or Brian.Lambe@ncdenr.gov Since Brian Lambe Environmental Specialist Land Quality Section North Carolina Department of Environmental Quality I Division of Energy, Mineral and Land Resources Wilmington Regional Office 1127 Cardinal Drive Extension I Wilmington, North Carolina 28405 riomH craauHn o.,..m..auwa.4„rurq 910.796.7215 NCG 190050 USCG SFO FT MACON Page 2 of 2 Attachments: 1. BIMS Inspection Checklist cc: ORO Files — Land Quality Central Files—Laserfiche Permit: NCG190050 SOC: County: Carteret Region: Wilmington Contact Person: Todd M Ogle Directions to Facility: System Classifications: Primary ORC: Secondary ORC(s): On -Site Representative(s): Related Permits: Compliance Inspection Report Effective: 06/02/15 Expiration: 05/31/20 Owner: United States Coast Guard Effective: Expiration: Facility: Fort Macon Coast Guard Station - Atlantic Beach 2301 E Fort Macon Rd Inspection Date: 01116/2020 Entry Primary Inspector: Brian P Lambe Secondary Inspector(s): Title: 10.30AM Certification: Atlantic Beach NC 28512 Phone: 252-247-4534 Phone: Exit Time: 11:30AM Phone: Reason for Inspection: Routi�` �/ Inspection Type: Compliance Evaluation Permit Inspection Type: Ship and Boat Building Stormwater Discharge COC Facility Status: Compliant Not Compliant Question Areas: Storm water (See attachment summary) Page 1 of 3 permit: NCG190050 Owner- Facility: United States Coast Guard Inspection Date: 01/16/2020 Inspection Type : Compliance Evaluation Reason for Visit: Routine Inspection Summary: The samples are pulled from a pipe that is underwater 14 hours a day. The pipe receives flow from an underground settling container, from a grated Swale. The solids are filtered out by a sock in the Swale. The yard is very clean with no visible staining from contaminants. Concentration of the stormwater in the collection device may be raising the sampling results, but that is only a theory. The sampling results do not represent the efforts of the facility to keep stormwater from being contaminated. The facility has requested relief of the tier response required by permit. Consideration of the facility condition warrants relief for Copper and Zinc. However, as an arbitrary checkpoint, if samples measure at unreasonable levels, exceeding all time highs for the facility, you must contact this office immediately. Please refer to 06/24/2016 sampling report. The relief of the tier system only extends to the end of he permit period. The permit period is coming to an end. Renewal is handled by the state. You do not need to do anything form your permit to be renewed. You will be notified if there are any changes to the permit. The facility does need to address the power -washing of the boats. The current SOP is to pump and haul to a facility that can handle the waste. A recycle system may prove to be more viable an option over the long term. Please reevaluate. Page 2 of 3 permit NCG190050 Owner- Facility: United Slates Coast Guard Inspection Date: 0111612020 Inspection Type : Compliance Evaluation Reason for Visit: Routine StormWater Pollution Prevention Plan Yes No NA NE Does the site have a Stormwater Pollution Prevention Plan? 0 ❑ ❑ ❑ # Does the Plan include a General Location (USGS) map? 0 ❑ ❑ ❑ # Does the Plan include a "Narrative Description of Practices"? ❑ ❑ ❑ # Does the Plan include a detailed site map including outfall locations and drainage areas? ❑ ❑ ❑ # Does the Plan include a list of significant spills occurring during the past 3 years? ❑ ❑ ❑ # Has the facility evaluated feasible alternatives to current practices? ❑ ❑ ❑ # Does the facility provide all necessary secondary containment? ❑ ❑ ❑ # Does the Plan include a PIMP summary? ❑ ❑ ❑ # Does the Plan include a Spill Prevention and Response Plan (SPRP)? N ❑ ❑ ❑ # Does the Plan include a Preventative Maintenance and Good Housekeeping Plan? 0 ❑ ❑ ❑ # Does the facility provide and document Employee Training? E ❑ ❑ ❑ # Does the Plan include a list of Responsible Pary(s)? M ❑ ❑ ❑ # Is the Plan reviewed and updated annually? 0 ❑ ❑ ❑ # Does the Plan include a Stormwater Facility Inspection Program? 0 ❑ ❑ ❑ Has the Stormwater Pollution Prevention Plan been implemented? 0 ❑ ❑ ❑ Comment Qualitative Monitoring Yes No NA NE Has the facility conducted its Qualitative Monitoring semi-annually? N ❑ ❑ ❑ Comment: Analytical Monitoring Yes No NA NE Has the facility conducted its Analytical monitoring? 0 ❑ ❑ ❑ # Has the facility conducted its Analytical monitoring from Vehicle Maintenance areas? ❑ ❑ ❑ Comment. Copoer levels measured 0.0261 ma/L on 12/13/2019. Historically the samples have randae from 0.01 to 0.07ni Zinc levels measured 0.122ma/L on 12113/2019. These metals have traditionally sampled above benchmark levels. Permit and Outfalls Yes No NA NE # Is a copy of the Permit and the Certificate of Coverage available at the site? N ❑ ❑ ❑ # Were all outfalls observed during the inspection? 0 ❑ ❑ ❑ # If the facility has representative outfall status, is it properly documented by the Division? ❑ ❑ N ❑ # Has the facility evaluated all illicit (non stormwater) discharges? E ❑ ❑ ❑ Comment: Page 3 of 3